{"product_id":"bently-nevada-330881-28-04-090-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-090-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-04-090-03-02\u003c\/strong\u003e: This configuration of the PROXPAC XL metric integrated transducer combines a 3300 XL 8 mm proximity probe and an integrated Proximitor sensor inside a self-contained, glass-reinforced Polyphenylene Sulfide (PPS) housing. This specific variant is pre-configured with a 3300 XL 8 mm probe that features certified hazardous area multiple approvals (Option 28), a 40 mm standoff adapter (Option 04), a 90 mm probe penetration sleeve (Option 090), an M20 cable fitting with two sealing plugs (Option 03), and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\u003cp\u003eBy housing the Proximitor sensor directly in the casing lid, this integrated assembly eliminates the need for an external extension cable and separate Proximitor junction boxes. This simplifies installation, minimizes potential connector point failures, and facilitates fast external probe adjustment on rotating machinery. The conductive fiber construction of the PPS housing effectively dissipates electrostatic charges, while the overall design achieves a robust Type 4X and IP66 rating for reliability in harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Certified (Option 28):\u003c\/strong\u003e Equipped with a 3300 XL 8 mm probe carrying Multiple Approvals for Zone and Division classified applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Mounting Offset (Option 04):\u003c\/strong\u003e Features a 40 mm metric standoff adapter to accommodate specific machinery case dimensions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Probe Penetration (Option 090):\u003c\/strong\u003e Built with a 90 mm probe penetration depth to ensure accurate proximity measurements on the target shaft.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Entry Fitting (Option 03):\u003c\/strong\u003e Supplied with a protective fitting kit containing one M20 conduit adapter and two blanking plugs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting Threads (Option 02):\u003c\/strong\u003e Integrates a 3\/4-14 NPT outer sleeve thread structure for mounting alignment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelf-Contained Architecture:\u003c\/strong\u003e Integrates the probe and Proximitor sensor into a single unit, allowing direct connection to field wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Housing:\u003c\/strong\u003e Advanced polyphenylene sulfide (PPS) thermoplastic housing with conductive fibers prevents static buildup and withstands severe industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe integrated transducer is designed for several critical industrial applications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft dynamic vibration and axial position measurements on rotating machinery such as pumps, fans, and small compressors.\u003c\/li\u003e\n  \u003cli\u003eHarsh environmental monitoring locations requiring Type 4X and IP66 moisture and particulate protection.\u003c\/li\u003e\n  \u003cli\u003eHazardous industrial environments requiring intrinsically safe (Ex ia) or non-sparking (Ex nA\/Ex ec) installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-04-090-03-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option (B Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option (C Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e090\u003c\/td\u003e\n      \u003ctd\u003e90 mm probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (Required for standoff adapter configurations)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-04-090-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe with 1-metre cable installed in the sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Environmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve \u0026amp; Retaining Screws Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe Only)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrostatic Protection:\u003c\/strong\u003e Verify that the grounding liner and retaining plate are properly aligned and grounded during mounting to prevent static electricity discharge.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Use the provided M20 cable fitting and seal all unused conduit entry holes with the supplied plastic blanking plugs to maintain the housing IP66 rating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Offset Adjustment:\u003c\/strong\u003e The threaded outer sleeve allows an adjustment range of plus or minus 12.7 mm (0.5 in) from the nominal mounting position to achieve precise probe-to-target gapping.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Tighten the probe sleeve locknut to 39.3 N-m (350 in-lb) and the outer casing retaining screws to 29.5 N-m (260 in-lb) for mechanical security.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Fully compliant with European CE directives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (Intrinsically Safe):\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc for classified hazardous zones.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (Non-Sparking):\u003c\/strong\u003e Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA\/cNRTLus (Classified Area):\u003c\/strong\u003e Class I, Zone 0, AEx\/Ex ia IIC T4\/T5 Ga; Class I, Division 2, Groups A, B, C, and D.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e Certified IP66 and NEMA Type 4X rating verified by BASEEFA.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666736607595,"sku":"330881-28-04-090-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-090-03-02-proxpac-xl-proximity-transducer-1yo3uxlyawr_26b69bd1-3246-4ab6-be15-aad2e3a491c8.jpg?v=1765446806","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330881-28-04-090-03-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}