{"product_id":"bently-nevada-330881-28-08-090-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-08-090-00-02 PROXPAC XL Transduser Proksimit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (multiple-approved 3300 XL 8 mm probe), Option 08 (80 mm standoff adapter), and Option 090 (90 mm penetration) specify this integrated \u003cstrong\u003e330881-28-08-090-00-02\u003c\/strong\u003e \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e configuration with a 3\/4-14 NPT mounting thread and no additional conduit fittings.\u003c\/p\u003e\n\u003cp\u003eThis integrated system combines a 3300 XL 8 mm proximity probe and its matching Proximitor sensor directly within a protective polyphenylene sulfide (PPS) thermoplastic housing. By consolidating these components, the assembly eliminates the requirement for separate external extension cables and standalone Proximitor enclosures. The integrated design reduces installation labor, minimizes electrical connections, and simplifies field wiring direct to monitoring racks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 configuration includes a 3300 XL 8 mm probe pre-installed inside the protective sleeve with Multiple Approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 08 standoff adapter provides an 80 mm extension for external adjustment and access of the probe.\u003c\/li\u003e\n  \u003cli\u003eOption 090 provides a 90 mm probe penetration length into the machinery casing.\u003c\/li\u003e\n  \u003cli\u003eOption 02 mounting thread specifies a 3\/4-14 NPT thread for secure mechanical integration.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) housing material containing glass and conductive fibers to dissipate electrostatic charges.\u003c\/li\u003e\n  \u003cli\u003eType 4X and IP66 environmental protection ratings for severe industrial installations.\u003c\/li\u003e\n  \u003cli\u003eIntegral design removes the need for an external extension cable by mounting the Proximitor sensor directly in the housing lid.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position monitoring on rotating machinery such as industrial steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n  \u003cli\u003eMachinery casing locations requiring external probe replacement or gap adjustment without complete machine teardown.\u003c\/li\u003e\n  \u003cli\u003eSevere environmental installations containing high humidity, corrosive elements, or potential electrostatic hazards.\u003c\/li\u003e\n  \u003cli\u003eHazardous area machinery protection environments requiring intrinsically safe or non-incendive explosion protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e08\u003c\/td\u003e\n      \u003ctd\u003e80 mm standoff length (increments of 10 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e090\u003c\/td\u003e\n      \u003ctd\u003e90 mm penetration length (increments of 1 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification \/ Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-08-090-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe (Option 28, Multiple Approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-5% nominal including interchangeability error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExcitation Power Requirement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV output voltage change per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0 dB, -3 dB (with up to 305 m field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUV-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve \/ Retaining Chain Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring (seals differential pressure between probe tip and housing body)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF) operating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing \u0026amp; Proximitor Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) operating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe field wiring terminals are located inside the housing cover on the Proximitor sensor module. A standard three-wire connection connects the PROXPAC XL to the machine monitoring system:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower (-Vtx)\u003c\/li\u003e\n  \u003cli\u003eSignal (OUT)\u003c\/li\u003e\n  \u003cli\u003eCommon (COM)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGrounding is facilitated through the stainless steel grounding liner and retaining plate inside the enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the sleeve using the 3\/4-14 NPT mounting thread (Option 02). Proper sealing of the casing entry thread is recommended to prevent process fluid leaks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Adjust the probe depth within the sleeve. The recommended installation gap is 1.27 mm (50 mils) from the shaft surface, which corresponds to the mid-point of the linear operating range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit \u0026amp; Wiring:\u003c\/strong\u003e Route field wiring using appropriate conduit. Since Option 00 specifies no fittings, ensure proper entry glands or flexible conduit connections are used to maintain the IP66 and Type 4X ratings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMoisture Prevention:\u003c\/strong\u003e Ensure all plugs, washers, and housing cover screws are fully torqued. Apply sealing methods to the conduit entry to prevent condensation from traveling through the conduit into the PPS housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Ratings:\u003c\/strong\u003e Sleeve Locknut: 39.3 N-m (350 in-lb); Retaining Nut: 29.5 N-m (260 in-lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark (EMC Directive 2014\/30\/EU: EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eCSA (CNRTLus) Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n  \u003cli\u003eCSA (CNRTLus) Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc; AEx\/Ex ec IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc; Ex nA IIC T5...T1 Gc; Ex ec IIC T5...T1 Gc\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666736640363,"sku":"330881-28-08-090-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-08-090-00-02-proxpac-xl-proximity-transducer-4ndvf4j40ef_710e3870-67b1-40cf-aa6c-7a07703c3bff.jpg?v=1765446807","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330881-28-08-090-00-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}