{"product_id":"bently-nevada-330881-28-10-140-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-10-140-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-10-140-00-02\u003c\/strong\u003e specifies this metric PROXPAC XL Proximity Transducer assembly configuration, featuring a 3300 XL 8 mm proximity probe with multiple approvals, a 100 mm standoff adapter, a 140 mm probe penetration length, no conduit fittings, and a 3\/4-14 NPT mounting thread.\u003c\/p\u003e\n\n\u003cp\u003eThis integrated assembly packages both the 3300 XL 8 mm probe and its matching 1-metre Proximitor sensor inside a single protective Polyphenylene Sulfide (PPS) thermoplastic housing cover. This structure removes the necessity for a traditional intermediate extension cable and separate Proximitor sensor housing. Field wiring is routed directly to the internal terminals, reducing signal losses and connector points. Unlike sibling variants that lack hazardous area approvals or utilize English dimensions, this metric configuration carries multiple hazardous area certifications and uses a 100 mm metric standoff adapter to meet specific mechanical offset requirements on classified machinery casings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Design:\u003c\/strong\u003e Houses a 1-metre 3300 XL 8 mm proximity probe and Proximitor sensor in a single unit, eliminating extension cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetric Configuration:\u003c\/strong\u003e Built with metric options, including a 100 mm standoff adapter (Option 10) and a 140 mm probe penetration sleeve (Option 140).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Housing:\u003c\/strong\u003e Molded from glass-reinforced Polyphenylene Sulfide (PPS) thermoplastic with conductive fibers to dissipate electrostatic charges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e Rated Type 4X and IP66 for protection against dust and high-pressure water jets in severe environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Approvals:\u003c\/strong\u003e Option 28 probe and approvals configuration provides intrinsically safe and non-incendive hazardous area ratings (ATEX, IECEx, and North American approvals).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Mounting:\u003c\/strong\u003e Uses a 3\/4-14 NPT mounting thread (Option 02) for mechanical attachment to the machine casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug and Washer Kit:\u003c\/strong\u003e Option 00 fittings option includes two plugs and two washers with no external conduit fittings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis integrated transducer system is used for non-contact machinery vibration, shaft displacement, and axial position monitoring in industrial environments. Typical industries and equipment include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine shaft vibration and position monitoring\u003c\/li\u003e\n\u003cli\u003eCentrifugal and axial compressor protection systems\u003c\/li\u003e\n\u003cli\u003eLarge industrial pumps, fans, and gearboxes\u003c\/li\u003e\n\u003cli\u003eClassified hazardous locations requiring intrinsically safe or non-incendive instrumentation\u003c\/li\u003e\n\u003cli\u003eSevere outdoor or washdown environments requiring IP66 and Type 4X enclosure protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-10-140-00-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e100 mm standoff adapter length (ordered in increments of 10 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e140 mm probe penetration length (ordered in increments of 1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (required if ordering Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-10-140-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePairs with 3300 XL monitoring systems and inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGlass-reinforced, UV-resistant Polyphenylene Sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve \u0026amp; Standoff Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66 and NEMA Type 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), from approximately 0.25 mm to 2.3 mm (10 mils to 90 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-5% (including interchangeability error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG), up to 305 m (1,000 ft) maximum between Proximitor and monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-metre length, 75 ohm triaxial, FEP insulated with gold-plated ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Seal (Probe Case)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-ring (seals differential pressure between probe tip and housing body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSleeve Alignment:\u003c\/strong\u003e Thread the probe sleeve into the machine casing using the 3\/4-14 NPT thread. Ensure correct locknut torque is applied.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Set the initial mechanical gap at the center of the linear range (typically 1.27 mm or 50 mils) to obtain the nominal -10 Vdc bias output prior to final tightening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Connect standard 3-conductor shielded triaxial field wiring directly to the internal terminals of the Proximitor sensor inside the housing cover. Avoid tight bends or routing near high-voltage lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Prevention:\u003c\/strong\u003e Take appropriate precautions to prevent moisture or condensation from traveling through the conduit run into the PPS enclosure. Seal all conduit entries appropriately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the internal grounding plate and liner according to Bently Nevada drawing 141092 or 140979 depending on the hazard classification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with applicable European Union directives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Complies with ATEX, IECEx, and North American (cNRTLus) standards for Class I, Zone 0\/Class I, Division 1 intrinsically safe installations when used with zener barriers or galvanic isolators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive:\u003c\/strong\u003e Certified for Class I, Division 2 and Class I, Zone 2 (Ex nA \/ Ex ec) installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Performance:\u003c\/strong\u003e Housing certified to withstand a 4 Joule impact at temperature extremes (-39 degC and 115 degC) per BASEEFA specifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666753778027,"sku":"330881-28-10-140-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-10-140-00-02-proxpac-xl-proximity-transducer-k5ocpvgsveq_ad22db20-7737-4934-be43-6ba194ae926d.jpg?v=1765447007","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330881-28-10-140-00-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}