{"product_id":"bently-nevada-330901-00-08-10-02-05-3300-nsv-proximity-probes","title":"Bently Nevada 330901-00-08-10-02-05 3300 NSv Proximity Probes","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330901-00-08-10-02-05\u003c\/strong\u003e configuration specifies a \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e featuring a 1\/4-28 UNF thread design engineered without stainless steel armor. This orderable part number is configured with a 0.0-inch unthreaded length (Option 00) and an overall case length of 0.8 inches (Option 08), which represents the minimum case length available for this series. The integrated probe lead has a total length of 1.0 meter (Option 10) and is constructed from standard coaxial cable terminating in a male miniature coaxial ClickLoc connector (Option 02), supplied with multiple hazardous area approvals (Option 05).\u003c\/p\u003e\n\n\u003cp\u003eOperating as a key sensor within the 3300 XL NSv Proximity Transducer System, this unarmored standard-cable probe is optimized for tight-clearance installations on small-bore rotating machinery and aeroderivative gas turbines. By utilizing high-frequency eddy-current technology, it is able to perform non-contact shaft vibration and axial position measurements in compact spatial envelopes with reduced target area geometries. Unlike armored models (such as the 330902 series) or variants with integrated connector protectors, this streamlined unarmored configuration facilitates direct routing through conduit and standard machine housings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThreaded Case Geometry: 1\/4-28 UNF-2A threaded probe body without armor, designed for direct threaded mounting.\u003c\/li\u003e\n\u003cli\u003eFully Threaded Body: Option 00 specifies a 0.0-inch unthreaded length, allowing the maximum range of depth adjustment during installation.\u003c\/li\u003e\n\u003cli\u003eUltra-Compact Case: Option 08 provides a 0.8-inch case length to fit within severe physical restrictions inside high-speed equipment.\u003c\/li\u003e\n\u003cli\u003e1.0-Meter Total Lead: Option 10 integrated 1.0-meter (39-inch) coaxial cable provides a direct connection to the extension cable.\u003c\/li\u003e\n\u003cli\u003eStandard Cable Connection: Option 02 miniature male ClickLoc connector offers secure, low-loss coupling with standard 75 ohm extension cables.\u003c\/li\u003e\n\u003cli\u003eComprehensive Certification: Option 05 qualifies the probe for multiple international agency approvals in hazardous area applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAxial position and shaft vibration measurements on high-speed aeroderivative gas turbines.\u003c\/li\u003e\n\u003cli\u003eRadial vibration and shaft position monitoring in small-bore rotating machinery with limited target geometries.\u003c\/li\u003e\n\u003cli\u003eEquipment vibration monitoring where small shaft diameters or small target areas restrict standard-size probe usage.\u003c\/li\u003e\n\u003cli\u003eMachinery diagnostics and protection systems requiring high-frequency non-contact displacement sensing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330901-00-08-10-02-05\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20 mm) overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 in) total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330901-00-08-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.26 mm (0.207 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnarmored (without stainless steel armor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc (male)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), starting at 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz (+0, -3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 ohm +\/- 0.5 ohm (for 1.0 m lead)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-ring pressure seal between probe tip and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 N m (45 in lb) recommended, 7.3 N m (65 in lb) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eObserve the following engineering and mechanical requirements to ensure proper installation and longevity of the probe:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA #3 or larger tap drill is recommended when drilling and tapping mounting holes for this 1\/4-28 probe.\u003c\/li\u003e\n\u003cli\u003eThe maximum thread engagement length for a 1\/4-28 case size is 0.375 inches. Ensure the mounting bracket or hole does not exceed this limit to avoid binding.\u003c\/li\u003e\n\u003cli\u003eAlways torque the probe case to the recommended 5.1 N m (45 in lb). Do not exceed the absolute maximum rated torque of 7.3 N m (65 in lb).\u003c\/li\u003e\n\u003cli\u003eRoute the integrated 75 ohm cable carefully, respecting the minimum bend radius of 25.4 mm (1.0 in) to prevent internal conductor damage.\u003c\/li\u003e\n\u003cli\u003eKeep the probe-to-extension cable connections dry and clean. For installations exposed to liquids, use silicone self-fusing tape or an accessory connector protector kit to shield the ClickLoc connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eWhen integrated with a compatible 3300 XL NSv Proximitor Sensor and extension cable, the 330901-00-08-10-02-05 probe meets the requirements of the following standards under Option 05:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\/IECEx: Intrinsically Safe (Ex ia IIC T5...T1 Ga) and Non-Sparking\/Ec (Ex nA\/Ex ec IIC T5...T1 Gc) for hazardous locations.\u003c\/li\u003e\n\u003cli\u003eNorth American (CSA\/NRTL\/C): Class I, Division 1, Groups A, B, C, and D; Class II, Groups E, F, and G; Class III.\u003c\/li\u003e\n\u003cli\u003eEnvironmental: Tested to IEC 68-2-3 damp heat standards, rated for 100% condensing humidity when connectors are properly insulated.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666746306923,"sku":"330901-00-08-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-08-10-02-05-3300-nsv-proximity-probes-ubgedoqwpo1_0233b414-b51b-4800-a245-c96b71183b2e.jpg?v=1765446946","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330901-00-08-10-02-05-3300-nsv-proximity-probes","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}