{"product_id":"bently-nevada-330901-00-10-10-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-10-10-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330901-00-10-10-02-05\u003c\/strong\u003e specifies this 3300 NSv proximity probe configuration, featuring a 1\/4-28 UNF thread without stainless steel armor, a 0.0 in unthreaded length (Option 00), a 1.0 in case length (Option 10), a 1.0 m (39 in) total length (Option 10), a ClickLoc miniature coaxial connector with standard FEP-insulated coaxial cable (Option 02), and Multiple Approvals certification (Option 05).\u003c\/p\u003e\n\n\u003cp\u003eThis eddy-current non-contacting displacement probe is a core transducer component for the 3300 XL NSv Proximity Transducer System. It is intended for installations with tight clearance requirements, small-bore machinery, or reduced target areas where standard 5 mm or 8 mm systems cannot be used due to counterbore, side-view, or rear-view restrictions. It is typically used for radial vibration, radial position, and axial position measurements on fluid-filmed bearing machines with shafts smaller than 51 mm (2.0 in) or flat targets smaller than 15 mm (0.6 in). The probe is fully compatible and interchangeable with previous 3300 RAM proximity probes and operates by connecting to a 3300 NSv extension cable and a 3300 XL NSv Proximitor Sensor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1\/4-28 UNF-2A thread configuration without stainless steel armor for direct, standard mounting applications.\u003c\/li\u003e\n\u003cli\u003e0.0 in unthreaded length (Option 00) allowing full thread engagement in compact spaces.\u003c\/li\u003e\n\u003cli\u003e1.0 in overall case length (Option 10) providing a low-profile installation depth.\u003c\/li\u003e\n\u003cli\u003e1.0 meter (39 in) FEP-insulated coaxial cable (Option 10) for standard system connections.\u003c\/li\u003e\n\u003cli\u003eMiniature male coaxial ClickLoc connector (Option 02) with gold-plated brass contacts preventing connection loosening.\u003c\/li\u003e\n\u003cli\u003eOption 05 Multiple Approvals package covering ATEX, IECEx, and North American hazardous location standards.\u003c\/li\u003e\n\u003cli\u003ePolyphenylene sulfide (PPS) probe tip material for increased chemical resistance in process gas environments.\u003c\/li\u003e\n\u003cli\u003eTipLoc molding and CableLoc design providing up to 220 N (50 lb) of pull strength between the probe tip, case, and lead.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration and axial position measurements on centrifugal, refrigeration, and process gas compressors.\u003c\/li\u003e\n\u003cli\u003eTachometer, zero-speed, and phase reference (Keyphasor) monitoring on aeroderivative gas turbines.\u003c\/li\u003e\n\u003cli\u003eMachinery protection on high-speed rotating equipment with tight clearance constraints and small shaft geometries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330901-00-10-10-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 in case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 in) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330901-00-10-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A threads\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eWithout stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 in (25 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, FEP insulated, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (gold-plated brass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from approximately 0.25 to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5%\/-20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe DC Resistance (R_probe)\u003c\/td\u003e\n      \u003ctd\u003e4.2 +\/-0.5 ohms (center conductor to outer shield)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum Rated)\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Sealing Material\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring pressure seal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approvals\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (Option 05: CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhen drilling and tapping a mounting hole for this 1\/4-28 UNF probe, a #3 or larger tap drill is recommended.\u003c\/li\u003e\n\u003cli\u003eAvoid exceeding the maximum recommended installation torque of 5.1 N-m (45 in-lb) for 1\/4-28 UNF probe cases. The absolute maximum rated torque is 7.3 N-m (65 in-lb).\u003c\/li\u003e\n\u003cli\u003eEnsure the minimum bend radius of 25.4 mm (1.0 in) is maintained for the coaxial cable to prevent mechanical or signal damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the combined length of the probe and extension cable equals the designated system length of the Proximitor Sensor (typically 5.0 or 7.0 meters).\u003c\/li\u003e\n\u003cli\u003eSustained exposure to temperatures below -34 degC may degrade the internal Viton pressure seal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\/IECEx: Intrinsically safe for Class I, Zone 0, Ex ia IIC Ga (when installed with approved barriers).\u003c\/li\u003e\n\u003cli\u003eCSA\/NRTL\/C: Class I, Zone 0, AEx\/Ex ia IIC Ga; Class I, Groups A, B, C, and D; Class II, Groups E, F, and G; Class III.\u003c\/li\u003e\n\u003cli\u003eEMC Directive: 2014\/30\/EU (EN 61000-6-2 and EN 61000-6-4 standards).\u003c\/li\u003e\n\u003cli\u003eRoHS Directive: 2011\/65\/EU and China RoHS compliance (EFUP 15 years).\u003c\/li\u003e\n\u003cli\u003eFunctional Safety: Certified for SIL 2 (HFT = 0) and SIL 3 (HFT = 1) applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666616349035,"sku":"330901-00-10-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-10-10-02-05-3300-nsv-proximity-probes-unptmtaltze_63909998-f079-4540-92f0-4123d2f5f411.jpg?v=1765444197","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330901-00-10-10-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}