{"product_id":"bently-nevada-330901-10-25-10-02-00-3300-nsv-proximity-probe","title":"Bently Nevada 330901-10-25-10-02-00 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330901-10-25-10-02-00\u003c\/strong\u003e is an unarmored \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e configured with a 1\/4-28 UNF thread, a 1.0-inch unthreaded case length, a 2.5-inch overall case length, a 1.0-meter total cable length, and a miniature coaxial ClickLoc connector on standard cable, without requiring hazardous area agency approvals. This non-contact, eddy-current displacement sensor is designed for tight clearances and reduced target areas where standard-sized proximity probe tips are too large to fit.\u003c\/p\u003e\n\u003cp\u003eThis 330901 configuration differs from armored models (such as the 330902 series) by omitting stainless steel armor on the 75-ohm coaxial lead, which allows for increased cable flexibility during routing in tight machinery casings. The Option 02 miniature coaxial ClickLoc connector provides a secure locking mechanism with a standard connection profile, making it suitable for clean, dry installations where a fluid-sealed connector protector (such as Option 01) is not required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 10 unthreaded length specifies a 1.0-inch unthreaded casing section.\u003c\/li\u003e\n  \u003cli\u003eOption 25 case length provides a 2.5-inch overall threaded casing length, allowing adjustable installation depth in machine housings.\u003c\/li\u003e\n  \u003cli\u003eOption 10 total length includes a 1.0-meter (39 in) integrated FEP-insulated coaxial cable lead.\u003c\/li\u003e\n  \u003cli\u003eOption 02 connector defines a gold-plated brass miniature coaxial ClickLoc connector on standard (non-FluidLoc) cable.\u003c\/li\u003e\n  \u003cli\u003eOption 00 approval package indicates that no agency approvals or certifications are required for this general-purpose model.\u003c\/li\u003e\n  \u003cli\u003eTipLoc molding method provides a robust chemical-resistant bond between the polyphenylene sulfide (PPS) probe tip and the AISI 303 stainless steel body.\u003c\/li\u003e\n  \u003cli\u003eCableLoc design secures the cable to the probe assembly, offering 220 N of pull strength to prevent mechanical separation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis transducer is designed for non-contact displacement, radial vibration, and axial position monitoring on high-speed rotating machinery with limited target geometries. Common applications include small-bore machinery, aeroderivative gas turbines, high-speed centrifugal compressors, and tight radial clearances where proximity probes must be mounted close together. It connects to the 3300 XL NSv Proximitor Sensor (330980) and 3300 NSv extension cable (330930).\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eConfigured Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 in (25 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25\u003c\/td\u003e\n      \u003ctd\u003e2.5 in (64 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector \u0026amp; Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-10-25-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) typical when paired with 330980 Proximitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), beginning at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) over linear range (0 to 45 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMinimum 13 mm (0.5 in) flat target diameter (8.9 mm absolute minimum)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCasing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel (S30300) with polyphenylene sulfide (PPS) tip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial cable, FEP insulated, FEP jacket (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.2 +\/- 0.5 ohms (center conductor to outer shield)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Case-to-Lead)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) maximum pull strength\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.3 N-m (65 in-lb) rated; 5.1 N-m (45 in-lb) recommended\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintain a minimum separation of at least 25 mm (1.0 in) for axial setups or 23 mm (0.9 in) for radial vibration setups to prevent electromagnetic cross-talk.\u003c\/li\u003e\n  \u003cli\u003eAvoid exposing the probe to temperatures below -34 degC (-30 degF) for sustained periods to protect the internal Viton pressure seal.\u003c\/li\u003e\n  \u003cli\u003eUse a #3 or larger tap drill when preparing internal casing threads for the 1\/4-28 UNF-2A probe casing.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the maximum thread engagement length of 0.375 inches for 1\/4-28 threads.\u003c\/li\u003e\n  \u003cli\u003eTorque the probe case during installation to the recommended 5.1 N-m (45 in-lb) and do not exceed the maximum limit of 7.3 N-m (65 in-lb).\u003c\/li\u003e\n  \u003cli\u003eHand-tighten ClickLoc connectors; do not exceed 0.56 N-m (5 in-lb) of torque on coaxial connections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666857521515,"sku":"330901-10-25-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-10-25-10-02-00-probe-n1wlxz5iusk_34899573-8c99-4ca9-9b4e-552afbb848f6.jpg?v=1765449215","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330901-10-25-10-02-00-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}