{"product_id":"bently-nevada-330901-14-43-10-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330901-14-43-10-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 14 (1.4 inches unthreaded length) and Option 43 (4.3 inches overall case length) specify this 3300 NSv unarmored proximity probe configuration — \u003cstrong\u003e330901-14-43-10-02-05\u003c\/strong\u003e, an eddy-current \u003cstrong\u003eproximity probe\u003c\/strong\u003e with a 1\/4-28 UNF thread suitable for restricted target spaces. This specific build features a 1.0 meter total cable length (Option 10) terminated with a miniature coaxial ClickLoc connector on standard unarmored cable (Option 02) and is certified for multiple hazardous area approvals (Option 05).\u003c\/p\u003e\n\u003cp\u003eUnlike armored options like the 330902 model or configurations with integrated connector protectors (Option 01), this configuration utilizes a streamlined, unarmored FEP insulated cable design for applications where external protective conduit or mechanical shielding is already provided. The 3300 NSv transducer system operates on a 1.5 mm (60 mils) linear range and is optimized for small-bore machinery or tight sideview clearances where standard 8 mm or 5 mm probes are limited by electromagnetic crosstalk and boundary restrictions.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 14 unthreaded length provides 1.4 inches of non-contact clearance.\u003c\/li\u003e\n  \u003cli\u003eOption 43 overall case length provides 4.3 inches of thread reach using a standard 1\/4-28 UNF-2A thread.\u003c\/li\u003e\n  \u003cli\u003eOption 10 specifies a 1.0 meter (39 inches) probe total length, compatible with 3300 XL NSv Proximitor sensors and extension cables.\u003c\/li\u003e\n  \u003cli\u003eOption 02 miniature coaxial ClickLoc connector locks securely into place without a bulky silicone connector protector.\u003c\/li\u003e\n  \u003cli\u003eOption 05 multiple agency approvals package provides hazardous area certification including ATEX, IECEx, and CSA.\u003c\/li\u003e\n  \u003cli\u003eUnarmored coaxial cable construction utilizes 75 ohm fluoroethylene propylene (FEP) insulation for high chemical resistance.\u003c\/li\u003e\n  \u003cli\u003eTipLoc molding method forms a robust bond between the polyphenylene sulfide (PPS) probe tip and the stainless steel case.\u003c\/li\u003e\n  \u003cli\u003eCableLoc design provides up to 220 N (50 lb) of pull strength between the probe lead and the probe case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and radial position measurements on high-speed turbo-expanders or centrifugal air compressors.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position measurements on aeroderivative gas turbines.\u003c\/li\u003e\n  \u003cli\u003eSpeed and tachometer phase reference measurements (Keyphasor) on small shaft geometries under 51 mm (2.0 inches) in diameter.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection in tight casing clearances or deep counterbore restrictions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330901-14-43-10-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv proximity probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e14\u003c\/td\u003e\n      \u003ctd\u003e1.4 in (36 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length\u003c\/td\u003e\n      \u003ctd\u003e43\u003c\/td\u003e\n      \u003ctd\u003e4.3 in (109 mm) case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 in) probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx, and other certifications)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-14-43-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored FEP jacketed coaxial cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Cable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance (R_PROBE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.2 ohms +\/- 0.5 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from approximately 0.25 mm to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over 0 degC to 45 degC range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/- 0.06 mm (+\/- 2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (up to 305 m \/ 1000 ft field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) maximum rated from probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass miniature male coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Torque (1\/4-28 UNF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.1 N-m (45 in-lb) recommended, 7.3 N-m (65 in-lb) maximum rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring pressure seal between probe tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930 extension cable and 330980 Proximitor sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTap Drill Selection:\u003c\/strong\u003e Use a #3 or larger tap drill when preparing mounting holes for 1\/4-28 UNF probe installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCase Torque Limit:\u003c\/strong\u003e Tighten the probe case to a recommended torque of 5.1 N-m (45 in-lb). Do not exceed the maximum limit of 7.3 N-m (65 in-lb) to prevent damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 inch) along the coaxial probe lead and any connected extension cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Care:\u003c\/strong\u003e Finger-tighten the ClickLoc connectors. The maximum recommended torque is 0.56 N-m (5 in-lb). Use silicone tape or connector protectors to exclude ambient moisture.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Keep thread engagement within the 0.375-inch limit for 1\/4-28 UNF probe cases to avoid binding during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 2014\/30\/EU (EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (HFT = 0), SIL 3 capable (HFT = 1)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05):\u003c\/strong\u003e CSA, ATEX, and IECEx certifications for Class I Zone 0\/Zone 2, Groups A, B, C, D (Ex ia IIC T5...T1 Ga and Ex nA\/Ex ec IIC T5...T1 Gc)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666737918315,"sku":"330901-14-43-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-14-43-10-02-05-proximity-probe-bk1acqcdhw1_2b7a2567-88f5-47dc-a3b5-d24f952c974e.jpg?v=1765446835","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330901-14-43-10-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}