{"product_id":"bently-nevada-330902-00-10-10-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330902-00-10-10-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330902-00-10-10-02-05\u003c\/strong\u003e configuration specifies a \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e with integrated flexible stainless steel armor, a fully threaded 1\/4-28 UNF case (0.0 in unthreaded length and 1.0 in case length), a 1.0 m total cable length, standard coaxial ClickLoc connector, and comprehensive Option 05 multiple hazardous area approvals.\u003c\/p\u003e\n\n\u003cp\u003eAs a critical element of the Bently Nevada 3300 XL NSv Proximity Transducer System, this non-contacting eddy-current sensor is engineered specifically for applications with limited clearance or reduced target geometries, such as small-bore rotating machinery and aeroderivative gas turbines. The robust flexible AISI 302 stainless steel armor shields the 75-ohm coaxial cable against physical damage, mechanical cuts, and industrial wear. It operates by outputting a voltage directly proportional to the distance between the probe tip and the target, enabling highly accurate dynamic shaft vibration, axial position, and speed measurements when paired with a matching 330930 extension cable and a 330980 Proximitor sensor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Stainless Steel Armor (AISI 302)\u003c\/strong\u003e: Integrated protective sleeving safeguards the delicate FEP coaxial cable from abrasion and impact.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFully Threaded Case Option (00-10)\u003c\/strong\u003e: Designed with 0.0 inches of unthreaded length and a 1.0-inch total case length for maximum physical installation versatility in tight spaces.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1.0 Meter Lead Cable (Option 10)\u003c\/strong\u003e: Provides a practical 1.0 m (39 in) standard FEP-insulated coaxial cable suited for direct cabinet transitions or proximity junctions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMiniature ClickLoc Connector (Option 02)\u003c\/strong\u003e: Space-saving, low-profile gold-plated brass coaxial connection that ensures high-signal integrity without the added bulk of a connector protector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Certified (Option 05)\u003c\/strong\u003e: Factory-equipped with global agency certificates (ATEX, IECEx, cNRTLus) for installation in Class I, Division 1 and Zone 0 explosive atmospheres.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePolyphenylene Sulfide (PPS) Tip\u003c\/strong\u003e: Molded high-durability polymer tip resists chemical degradation, moisture infiltration, and high-pH solutions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position monitoring on high-speed aeroderivative gas turbines.\u003c\/li\u003e\n  \u003cli\u003eNon-contact displacement tracking on small-bore centrifugal compressors and auxiliary machinery.\u003c\/li\u003e\n  \u003cli\u003eSensing applications with constrained mounting areas, counterbores, or offset target locations.\u003c\/li\u003e\n  \u003cli\u003eHarsh industrial environments requiring mechanical armoring for cable protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330902-00-10-10-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, with stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length (fully threaded probe case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 in (25 mm) case length (ordered in increments of 0.1 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet \/ 39 inches) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (without connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (includes cNRTLus Class I Div 1\/2, ATEX\/IECEx Zone 0\/2\/22)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330902 Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCabling Armor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 stainless steel (SST) armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils). Begins at approx 0.25 mm (10 mils) to 1.75 mm (70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately -1 Vdc to -13 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) over 1.5 mm range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum Rated)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to probe lead and armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring design for differential pressure sealing between tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCase Torque Limit\u003c\/strong\u003e: Ensure installation torque for the 1\/4-28 thread does not exceed 5.1 N-m (45 in-lb) to prevent thread binding or internal sensor damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Adjustment\u003c\/strong\u003e: Adjust the initial gap using a voltmeter connected to the Proximitor sensor output. Set the distance to match a target reading of approximately -9.0 Vdc (1.0 mm or 40 mils gap).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Shielding and Routing\u003c\/strong\u003e: Route the armored cable through clean areas away from power conduits. Maintain a minimum bend radius of 25.4 mm (1.0 in) throughout the run.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Connection\u003c\/strong\u003e: Hand-tighten coaxial connectors until finger-tight (do not exceed 0.56 N-m or 5 in-lb). Apply silicone self-fusing tape to seal out moisture when installed in humid or oily environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (Intrinsically Safe)\u003c\/strong\u003e: Ex ia IIC T5...T1 Ga; Ex ia IIIC T90degC...T280degC Dc (for EPL Ga and Dc); Ex nA\/ec IIC T5...T1 Gc (for EPL Gc).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American cNRTLus\u003c\/strong\u003e: Class I, Zone 0, AEx\/Ex ia IIC T5...T1 Ga; Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e: Certified for use in SIL 2 (HFT = 0) or SIL 3 (HFT = 1) safety loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e: Compliant with EU RoHS and China RoHS specifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666619068779,"sku":"330902-00-10-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330902-00-10-10-02-05-3300-nsv-proximity-probes-mhvxcqxrffv_c76ed16a-76c0-46fd-83f5-00ac97f90580.jpg?v=1765444233","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330902-00-10-10-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}