{"product_id":"bently-nevada-9200-01-01-10-00-9200-two-wire-velocity-seismoprobe-transducer","title":"Bently Nevada 9200-01-01-10-00 9200 Two-Wire Velocity Seismoprobe Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for continuous machinery vibration monitoring, the \u003cstrong\u003e9200-01-01-10-00\u003c\/strong\u003e is a highly reliable \u003cstrong\u003evelocity seismoprobe transducer\u003c\/strong\u003e that measures absolute casing vibration. This two-wire, self-generating sensor converts mechanical vibration into an electrical voltage signal directly proportional to vibration velocity, eliminating the need for external excitation power.\u003c\/p\u003e\n\n\u003cp\u003eThis specific configuration is optimized for vertical mounting orientations (0 degrees plus\/minus 2.5 degrees) and features a low-frequency capability down to 4.5 Hz (270 cpm). Engineered to withstand the demanding environments of heavy industrial facilities, the \u003cstrong\u003e9200-01-01-10-00\u003c\/strong\u003e provides critical diagnostic data for predictive maintenance programs on rotating machinery such as pumps, fans, and compressors.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelf-Generating Design:\u003c\/strong\u003e Requires no external power supply to produce an output signal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTwo-Wire Interface:\u003c\/strong\u003e Simplifies wiring architecture and field installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTop Mount Connector:\u003c\/strong\u003e Provides convenient access for cable termination and routing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Enclosure:\u003c\/strong\u003e Designed to withstand harsh industrial environments and high-vibration applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePower generation steam and gas turbines\u003c\/li\u003e\n  \u003cli\u003eIndustrial air compressors and blowers\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment pumps\u003c\/li\u003e\n  \u003cli\u003ePetrochemical and refining rotating machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9200-01-01-10-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9200 Seismoprobe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Angle Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 plus\/minus 2.5 degrees\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Operating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.5 Hz (270 cpm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTop Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Base Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCircular, M10 x 1 threaded stud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor accurate vibration measurement and long-term reliability, adhere to the following installation standards:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Ensure the transducer is mounted within plus\/minus 2.5 degrees of the true vertical position (0 degrees) as designated by the 01 mounting option.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Surface:\u003c\/strong\u003e The mounting surface must be clean, flat, and free of paint or debris to ensure proper mechanical transmission of vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Tighten the M10 x 1 stud to the manufacturer-specified torque limits using appropriate hand tools; do not overtighten.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Use flexible conduit or secure cable trays to protect the top-mount connector and signal line from mechanical wear or environmental hazards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668307538283,"sku":"9200-01-01-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-01-01-10-00-k4x4przkfln_7d7ac32c-1d4c-4baa-a4be-151165031035.jpg?v=1765520720","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-9200-01-01-10-00-9200-two-wire-velocity-seismoprobe-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}