{"product_id":"bently-nevada-9571-02-standard-interconnect-cable","title":"Bently Nevada 9571-02 Standard Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered to deliver high-integrity signal transmission within critical machinery protection architectures, the \u003cstrong\u003eBently Nevada 9571-02\u003c\/strong\u003e facilitates low-noise connectivity between industrial transducers and monitoring systems. This heavy-duty cable features a \u003cstrong\u003e2-conductor twisted, shielded 22 AWG\u003c\/strong\u003e construction that actively minimizes electromagnetic interference (EMI) and cross-talk in harsh electromagnetic environments. Designed with a specialized \u003cstrong\u003e2-socket moisture-resistant female connector\u003c\/strong\u003e at one end and rugged terminal lugs at the other, this 2-foot cable ensures a highly secure electrical and mechanical interface for critical vibration monitoring points. It is built specifically for integration with local monitor racks, excluding use with the 21128 Velocity Transducer Housing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Noise Rejection:\u003c\/strong\u003e Twisted-pair configuration combined with an integrated shield drain wire isolates fragile transducer signals from plant EMI\/RFI.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Termination:\u003c\/strong\u003e Equipped with a molded, moisture-resistant 2-socket female connector for reliable sensor-side sealing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Panel Interfacing:\u003c\/strong\u003e Pre-terminated with high-quality terminal lugs for direct, reliable installation onto barrier strips and monitor backplanes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Mechanics:\u003c\/strong\u003e Optimally sized 22 AWG conductors maintain electrical continuity and mechanical durability under structural vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-Run Optimization:\u003c\/strong\u003e 2-foot minimum length design prevents excess cable slack, keeping control cabinets organized and free of inductive loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eMachinery protection system loops (e.g., Bently Nevada 3500 and 1900 series monitors).\u003c\/li\u003e\n  \u003cli\u003eProx probes and vibration sensor-to-junction box connections.\u003c\/li\u003e\n  \u003cli\u003eBalance-of-plant rotating machinery health monitoring.\u003c\/li\u003e\n  \u003cli\u003eShort-run internal cabinet and local structural transducer routing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.95rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9571-02\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCable Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStandard Interconnect Cable (2-Conductor Twisted, Shielded)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConductor Gauge\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e22 AWG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 feet (0.6 meters)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector End A\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2-socket moisture-resistant female connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector End B\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTerminal Lugs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNet Physical Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.11 kg (0.24 lbs) (Calculated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 kg (including packaging and protective spooling)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.95rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eConnector Pin \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Signal Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSocket Pin A\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSignal High \/ Dynamic Signal (+)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSocket Pin B\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSignal Common \/ Return (-)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTerminal Lugs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTermination points for terminal block connections at monitor panel\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOuter Shield \/ Drain\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGrounding shield (MUST terminate only at the monitor common ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 9571-02 interconnect cable is optimized for standard industrial monitor configurations. It is crucial to note that this specific standard cable is \u003cstrong\u003enot compatible\u003c\/strong\u003e with the Bently Nevada 21128 Velocity Transducer Housing due to diameter clearances and physical connection constraints. If your plant utilizes the 21128 housing, you must source a specialized splash-resistant or armored cable assembly built specifically for that enclosure profile.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this is a non-armored variant, care must be taken during routing. Avoid routing the 9571-02 directly parallel to high-voltage AC motor lines or variable frequency drive (VFD) output cables. Lack of mechanical armor means this cable should always be housed within dedicated, grounded conduit or cable trays when routed outside of localized, enclosed instrument cabinets to prevent physical shearing or crushing.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo ensure the integrity of high-frequency vibration diagnostics, always terminate the cable's shield drain wire at the monitor rack ground. Never ground the shield at both ends; double-grounding creates ground loops that inject 50\/60 Hz electrical noise into the signal path, which can lead to false instrumentation trips or corrupted spectral data.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: ELECTRICAL HAZARD\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eBefore starting the installation or termination of the 9571-02 cable, ensure the corresponding monitor panel loop power is completely de-energized. Verify there is no residual energy on adjacent terminal strips. Failure to isolate power paths can lead to short circuits, damage to delicate input card electronics, or personnel injury.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eRoute the interconnect cable from the transducer mounting point to the monitor cabinet, ensuring the bend radius does not fall below 3 inches (76 mm) to prevent internal wire strain.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eAlign the keying of the 2-socket female connector with the transducer plug. Fully insert and thread the coupling collar to compress the moisture-resistant seal. Hand-tighten securely.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eConnect the terminal lugs at the opposite end to the assigned screw terminal block of the monitor rack. Ensure the shield drain wire is connected cleanly to the instrument Earth terminal and insulated along the rest of its length.\u003c\/span\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668311830891,"sku":"9571-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9571-02-nbt0yfepqpp_389554c6-7316-4e10-ab97-76a16a61418a.jpg?v=1765520874","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-9571-02-standard-interconnect-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}