{"product_id":"delta-dop-h07e425-dop-h-touch-panel-human-machine-interface","title":"Delta DOP-H07E425 DOP-H Touch Panel Human Machine Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eAutomating complex setups and machine configurations requires a combination of operator mobility and robust safety systems, which is precisely what the \u003cstrong\u003eDelta DOP-H07E425\u003c\/strong\u003e handheld \u003cstrong\u003ehuman machine interface\u003c\/strong\u003e delivers. This industrial operator panel features a vivid 7-inch TFT LCD widescreen display, allowing engineers and operators to access critical diagnostic pages, system parameter configurations, and alarm logs directly at the machinery site. Engineered for ergonomic comfort and high durability, this device bridges the gap between fixed-mount controls and dynamic physical interaction on the plant floor.\u003c\/p\u003e\n\n\u003cp\u003eIntegrated hardware safety mechanisms, including a prominent emergency stop button and a rear-mounted 3-position enabling switch, ensure compliance with modern industrial machine safety standards. With its built-in Ethernet capability, the \u003cstrong\u003eDOP-H07E425\u003c\/strong\u003e provides rapid data updates and high-speed communication backplanes, making it a reliable choice for teaching pendants and mobile programming terminals.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e7-inch high-resolution widescreen TFT LCD displaying up to 65,536 colors.\u003c\/li\u003e\n  \u003cli\u003eIntegrated hardware-wired Emergency Stop switch and rear-mounted 3-position enabling switch.\u003c\/li\u003e\n  \u003cli\u003eOnboard 10\/100Base-T Ethernet port for seamless network integration.\u003c\/li\u003e\n  \u003cli\u003eRobust 32-bit RISC microcontroller executing real-time operations.\u003c\/li\u003e\n  \u003cli\u003eSDHC-compliant SD card slot for expanded logging and recipe management.\u003c\/li\u003e\n  \u003cli\u003eIntegrated USB Client Ver 2.0 port for straightforward configuration uploads and firmware maintenance.\u003c\/li\u003e\n  \u003cli\u003eErgonomic hand-held design with physical safety switches positioned for intuitive single-handed use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRobotic teaching pendants and path programming.\u003c\/li\u003e\n  \u003cli\u003eManual pulse generator (MPG) and localized axis control for CNC machine tools.\u003c\/li\u003e\n  \u003cli\u003ePackaging line commissioning and physical format adjustments.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems and overhead crane manual overrides.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eDelta Electronics\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eDOP-H07E425\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003eDOP-H\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDisplay Type\u003c\/td\u003e\n      \u003ctd\u003e7-inch Widescreen TFT LCD\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e800 x 480 pixels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBacklight\u003c\/td\u003e\n      \u003ctd\u003eLED Backlight (half-life 20,000 hours at 25 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDisplay Colors\u003c\/td\u003e\n      \u003ctd\u003e65,536 colors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating System\u003c\/td\u003e\n      \u003ctd\u003eDelta Real Time OS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcessor (MCU)\u003c\/td\u003e\n      \u003ctd\u003e32-bit RISC Microcontroller (400 MHz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlash ROM\u003c\/td\u003e\n      \u003ctd\u003e128 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRAM\u003c\/td\u003e\n      \u003ctd\u003e64 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackup Memory (SRAM)\u003c\/td\u003e\n      \u003ctd\u003e16 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 VDC (allowable range: -10% to +15%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd\u003e5.6 W max\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackup Battery\u003c\/td\u003e\n      \u003ctd\u003e3V Lithium Battery CR2032 x 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEthernet Port\u003c\/td\u003e\n      \u003ctd\u003e1 Port (10\/100Base-T)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB Client\u003c\/td\u003e\n      \u003ctd\u003e1 Port (Ver 2.0)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMemory Card Slot\u003c\/td\u003e\n      \u003ctd\u003eSD Card (supports SDHC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSafety Elements\u003c\/td\u003e\n      \u003ctd\u003eRed Emergency Stop Button, 3-Position Enabling Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-20 to 60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e10% to 85% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP55 equivalent\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.7 kg (unit weight)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface \/ Port\u003c\/th\u003e\n      \u003cth\u003eFunctional Assignment\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEthernet Port\u003c\/td\u003e\n      \u003ctd\u003eRJ-45 connector for TCP\/IP network integration and programming.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB Client\u003c\/td\u003e\n      \u003ctd\u003eDirect configuration, screen upload\/download, and diagnostic interfacing.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSD Card Slot\u003c\/td\u003e\n      \u003ctd\u003eSupports memory expansion, diagnostic logging, and recipe storage.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMain Cable Connector\u003c\/td\u003e\n      \u003ctd\u003eCombines DC power input, serial communication channels, and safety switch dry contacts.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the heavy-duty system cable is properly secured to avoid physical strain on the handheld connection ports.\u003c\/li\u003e\n  \u003cli\u003eAlways wire the physical emergency stop button and rear-mounted enabling switch directly into your system's hardwired safety loop or safety controller.\u003c\/li\u003e\n  \u003cli\u003eStore the handheld terminal in a dedicated wall cradle or mounting bracket when not actively in use to prevent mechanical shock or falls.\u003c\/li\u003e\n  \u003cli\u003eAvoid using the terminal in locations exposed to direct high-pressure liquids, oil mist, or corrosive gases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Compliant\u003c\/li\u003e\n  \u003cli\u003eUL Recognized Component\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102142587243,"sku":"DOP-H07E425","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/dop-h07e425-513wscumymx.png?v=1776137308","url":"https:\/\/www.plcprotech.com\/ms\/products\/delta-dop-h07e425-dop-h-touch-panel-human-machine-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}