{"product_id":"delta-electronics-vfd300cp43b-21-cp2000-fan-pump-vector-control-drive","title":"Delta Electronics VFD300CP43B-21 CP2000 Fan\/Pump Vector Control Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered specifically for energy-efficient HVAC and pumping systems, the \u003cstrong\u003eDelta Electronics VFD300CP43B-21\u003c\/strong\u003e represents a high-performance \u003cstrong\u003efan\/pump vector control drive\u003c\/strong\u003e within the rugged CP2000 Series. Designed to optimize fluid control processes, this variable frequency drive (VFD) delivers precise speed and torque regulation to reduce energy consumption in variable torque applications. It features advanced sensorless vector control alongside traditional V\/F control curves to match the load demands of modern industrial fluid systems.\u003c\/p\u003e\n\n\u003cp\u003eThis wall-mount drive is built to operate under demanding power profiles, accepting a 460V three-phase input and supplying up to 60 Amps of continuous current to support 30 kW (40 HP) AC motors. With built-in multi-pump control algorithms, integrated PID feedback loops, and dual-rating performance capabilities, the \u003cstrong\u003eVFD300CP43B-21\u003c\/strong\u003e provides direct building automation and process control integration without requiring external PLC modules for basic operations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication-Specific Tuning:\u003c\/strong\u003e Dedicated parameter groups for fans, centrifugal pumps, and water-supply sequences.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Pump Control:\u003c\/strong\u003e Built-in sequencing capacity to coordinate lead\/lag arrangements and balance run hours across multiple motor units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Communications:\u003c\/strong\u003e Embedded Modbus RTU\/ASCII and BACnet protocols for direct BMS and industrial network integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Protection:\u003c\/strong\u003e Features IP20 and NEMA 1 rated enclosures suitable for clean, wall-mounted electrical room installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Savings:\u003c\/strong\u003e Automated energy-optimization mode dynamically adjusts output voltage based on load fluctuations to minimize active power draw.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial and industrial HVAC air handling units (AHUs).\u003c\/li\u003e\n  \u003cli\u003eCooling tower fan speed modulation and heat exchanger control.\u003c\/li\u003e\n  \u003cli\u003eMunicipal water supply systems and wastewater lift stations.\u003c\/li\u003e\n  \u003cli\u003eConstant pressure irrigation and agricultural pumping arrays.\u003c\/li\u003e\n  \u003cli\u003eIndustrial boiler feed pumps and closed-loop circulation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDelta Electronics\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVFD300CP43B-21\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries Name\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCP2000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Function\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFan\/Pump Variable Frequency Drive (VFD)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplicable Motor Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 kW (40 HP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60 Amps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage \/ Phase\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e460V AC, 3-Phase (380V to 480V, 50\/60 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWall Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20 \/ NEMA 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.84 in x 15.75 in x 8.27 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Methods\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eV\/F Control, Sensorless Vector Control (SVC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper physical and electrical deployment ensures optimal performance and long service life for the drive system:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Install the drive strictly in a vertical orientation on a flat, non-flammable wall surface or backpanel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e Ensure a minimum of 50 mm clearance on both sides and 120 mm clearance above and below the unit to maintain convective air cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the ground terminal of the drive to a dedicated electrical system ground point. Do not loop ground connections between multiple VFDs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use shielded power cables for motor connections, and route control\/signal wiring in separate, grounded metal conduits to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102150779243,"sku":"VFD300CP43B-21","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd300cp43b-21-1f5fwnak4d0.png?v=1776138087","url":"https:\/\/www.plcprotech.com\/ms\/products\/delta-electronics-vfd300cp43b-21-cp2000-fan-pump-vector-control-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}