{"product_id":"ge-vernova-multilin-750-p5-g5-hi-a20-r-feeder-management-relay","title":"GE Vernova Multilin 750-P5-G5-HI-A20-R Feeder Management Relay","description":"\u003cp\u003eGE Vernova Multilin 750 Feeder Management Relay is a digital system intended for the comprehensive management, primary protection, and control of distribution feeders. Designed without automatic recloser functionality to distinguish it from the 760 series, this relay provides robust backup protection for buses, transformers, and transmission lines within a convenient draw-out construction. Equipped with full metering capabilities and analog input\/output options, it ensures high asset visibility and integrates into monitoring and control infrastructures.\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin 750-P5-G5-HI-A20-R\u003c\/strong\u003e is an industrialized protection system tailored for distribution feeders on solidly grounded, high-impedance grounded, or resonant grounded networks. The unit features dedicated 5 A phase current inputs and 5 A zero-sequence ground current inputs to accommodate specific fault detection profiles. Operating under a wide high-voltage control power range, the relay incorporates an independent eight-channel 4 to 20 mA analog output array alongside a front-panel red breaker closed LED indicator. By utilizing standard industrial protocols and options for serial and Ethernet physical layers, the \u003cstrong\u003eMultilin 750\u003c\/strong\u003e executes fast fault processing, interlocking, and status reporting to optimize substation automation and protect upstream transformers and distribution buses.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete protection suite containing phase, neutral, ground, and negative sequence instantaneous and time overcurrent elements.\u003c\/li\u003e\n\u003cli\u003eComprehensive ground protection capabilities via 5 A zero-sequence ground current inputs paired with neutral and ground overcurrent diagnostics.\u003c\/li\u003e\n\u003cli\u003eHigh-voltage universal power supply options supporting both AC and DC industrial stations.\u003c\/li\u003e\n\u003cli\u003eIntegrated analog output hardware supplying eight independent 4 to 20 mA channels for remote PLC or SCADA tracking.\u003c\/li\u003e\n\u003cli\u003eStandard front panel red LED indicator for distinct local breaker closed status confirmation.\u003c\/li\u003e\n\u003cli\u003eDraw-out construction type enabling quick chassis maintenance and minimized replacement downtime.\u003c\/li\u003e\n\u003cli\u003eBuilt-in diagnostic testing system featuring simulation modes to preview fault, pre-fault, and post-fault characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary protection and control for distribution feeders on solidly grounded, high-impedance grounded, or resonant (Peterson Coil) systems.\u003c\/li\u003e\n\u003cli\u003eBus blocking and interlocking protection coordination schemes.\u003c\/li\u003e\n\u003cli\u003eHigh-speed fault detection for arc flash mitigation.\u003c\/li\u003e\n\u003cli\u003eVoltage and frequency element-based automatic load shedding schemes.\u003c\/li\u003e\n\u003cli\u003eBackup protection for transmission lines, feeders, distribution buses, and power transformers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Code\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e750\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model: Feeder Management Relay (Without Autoreclose)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Current Inputs: 5 A secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround Current Inputs: 5 A zero sequence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply: 88 to 300 VDC, 70 to 265 VAC @ 48 to 62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Outputs: Eight 4 to 20 mA analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreaker Status LED: Red breaker closed LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Vernova\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 Series Feeder Management Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Current Input (P5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A current transformer (CT) secondary input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Sequence Current Input (G5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A zero sequence current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Power Supply Options (HI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 to 300 VDC, or 70 to 265 VAC @ 48 to 62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs (A20)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEight 4 to 20 mA analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Status LED (R)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed breaker closed LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\/Neutral\/Ground TOC Pickup Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05 to 20.00 x CT in steps of 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTOC Curve Shapes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI Extremely\/Very\/Moderately\/Normally Inverse; Definite Time; IEC Curve A\/B\/C and Short; FlexCurve A\/B; IAC Extreme\/Very\/Inverse\/Short\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIOC Delay Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +20 ms (at non-zero time delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.02 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Metering Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Metering Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure proper panel mounting alignment matching standard draw-out dimensions. Keep clearance optimized for ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a dedicated low-impedance ground connection at the chassis ground terminal before making any current transformer or control power connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT Wiring:\u003c\/strong\u003e Verify secure insertion into the automatic shorting terminals. Phase and ground inputs must match the specified 5 A primary or secondary CT ratios to prevent overcurrent saturation or measurement inaccuracies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Power Protection:\u003c\/strong\u003e Route lines through an external fuse or circuit breaker matching the HI voltage limits (88 to 300 VDC or 70 to 265 VAC) to avoid power circuit component failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Ground the communication line shields at the PLC or computer side only to prevent ground loop interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695409230187,"sku":"SR750-P5-G5-HI-A20-R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-multilin-750-p5-g5-hi-a20-r-feeder-management-relay-ub5pqct2a1t_711aeef5-038e-4ec3-b5eb-0b6e8c9d3fc7.jpg?v=1766134998","url":"https:\/\/www.plcprotech.com\/ms\/products\/ge-vernova-multilin-750-p5-g5-hi-a20-r-feeder-management-relay","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}