{"product_id":"honeywell-2mlr-m06p-masterlogic-200r-6-slot-cpu-base-unit","title":"Honeywell 2MLR-M06P MasterLogic 200R 6-Slot CPU Base Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe integration of multi-slot architecture within redundant control topologies is facilitated by the Honeywell 2MLR-M06P base unit, which serves as a dedicated 6-slot main CPU backplane for the MasterLogic programmable controller series. This backplane acts as the physical and electrical foundation, providing high-speed bus communication and power distribution lines to individual processor and expansion modules. Engineered for maximum physical stability, the Honeywell 2MLR-M06P structural chassis ensures reliable alignment of critical pin connectors, preventing communication dropouts under continuous industrial vibration.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eDedicated 6-slot structural profile allowing simultaneous installation of redundant CPUs and core communication interfaces.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-durability backplane bus connectors designed to withstand insertion wear during maintenance cycles.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eConstructed using high-grade polymers meeting the self-extinguishing UL 94V-0 flammability specification.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eLow passive power overhead to maximize overall cabinet energy efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eRedundant CPU installations within critical infrastructure control panels.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHeavy manufacturing process automation requiring dense slot configurations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eWater treatment facilities, power distribution, and petrochemical processing hubs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.95rem;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2MLR-M06P\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMasterLogic 200R\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModule Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e6 Slots (Main Base)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCompatible Processor Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2MLR-CPUH\/T, 2MLR-CPUH\/F\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e211 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFlammability Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUL 94V-0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePhysical Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e346 mm x 98 mm x 19 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.34 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 2MLR-M06P base maintains identical physical dimensions and signal routing properties as corresponding modules within the OEM co-developed LS Electric XGR series (specifically the XGR-M06P). System integrators must verify that firmware configurations (such as Ver 5.1 and higher) are aligned across both redundant CPU units before mounting them to this unified bus.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent micro-disconnections along the high-speed CPU synchronization bus, ensure that the mounting panel is completely flat. Mounting the 2MLR-M06P onto an uneven surface can induce physical torsion on the backplane PCB, causing intermittent \"Module Pull-Out\" alarms or unexpected failovers. Provide sufficient vertical clearance of at least 50 mm above and below the rack to maintain natural convection cooling across installed components.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEnsure that the grounding terminal on the power supply module attached to this base is connected directly to a low-impedance earth ground using minimum 2.0 mm² (14 AWG) copper wire. Floating ground potentials on the base plate can introduce high-frequency noise into the system backplane, resulting in checksum errors and degradation of the internal parallel bus communications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eDo not install, remove, or modify any modules on the 2MLR-M06P base plate while the system is energized. Failure to completely de-energize the main rack power supply can generate severe transient electrical arcs, permanently damaging the high-speed bus transceivers inside the backplane and any mounted CPU or expansion modules.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold; font-size: 0.9rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePosition the empty base plate against a clean, flat mounting panel inside the enclosure and align it with the pre-drilled M4 tapped screw holes.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold; font-size: 0.9rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSecurely tighten the mounting screws across all specified anchoring points to guarantee proper grounding and prevent mechanical flexure.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold; font-size: 0.9rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify that all backplane slot connectors are completely free of dust and debris before sliding and locking the CPU and functional modules into place.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705333051755,"sku":"2MLR-M06P","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/2mlr-m06p-dnhs32u4mpu_1b6f5f06-c38c-45df-85f1-3b3091a033eb.jpg?v=1766640689","url":"https:\/\/www.plcprotech.com\/ms\/products\/honeywell-2mlr-m06p-masterlogic-200r-6-slot-cpu-base-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}