{"product_id":"honeywell-cc-taix01-experion-c300-analog-input-module","title":"Honeywell CC-TAIX01 Experion C300 Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding the critical physical and electrical link between field instruments and the system controller, the \u003cstrong\u003eHoneywell CC-TAIX01\u003c\/strong\u003e serves as a high-density 16-channel Analog Input Input-Output Termination Assembly (IOTA) for the Experion C300 Series C platform. This module distributes loop power to process transmitters, collects continuous 4-20mA signals, and routes them to active C300 processing modules. Designed for high reliability in process automation architectures, it ensures clean signal integrity and robust physical cable termination in industrial control panels.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Density Channel Support:\u003c\/strong\u003e Terminations for up to 16 analog input channels configured in differential or single-ended modes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Loop Power:\u003c\/strong\u003e Built-in 24 VDC distribution with short-circuit and current-limiting protections per channel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Assembly:\u003c\/strong\u003e Facilitates redundant or non-redundant configurations with compatible active analog input modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Physical Termination:\u003c\/strong\u003e Industrial-grade screw clamp terminals provide strong resistance to mechanical vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Carrier Mounting:\u003c\/strong\u003e Clips directly to standard DIN rail mounting arrangements for simplified installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePetrochemical \u0026amp; Refining:\u003c\/strong\u003e Interfacing pressure, flow, and temperature transmitters with the central Honeywell DCS.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Continuous analog monitoring of auxiliary process variables and feedback loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Treatment Facilities:\u003c\/strong\u003e Level, flow, and analytical chemistry transmitter integrations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePulp \u0026amp; Paper Mills:\u003c\/strong\u003e Interfacing process instruments in high electrical noise environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eValue \/ Standard\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCC-TAIX01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePlatform Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eExperion C300 \/ Series C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eInput Output Termination Assembly (IOTA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNumber of Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e16 Analog Input Channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4 to 20 mA \/ 1 to 5 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Loop Power Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 VDC nominal\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e22.0 x 15.0 x 8.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eWiring and Interface Connections\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal Range\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminals 1 - 16 (Positive)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eChannels 1 through 16 Positive Signal \/ Loop Transmitter Power Output\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminals 17 - 32 (Negative)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eChannels 1 through 16 Analog Return Ground \/ Signal Return Input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eGround Bus Bar\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eShield \/ Drain Wire Terminations for Field Cable Assemblies\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CC-TAIX01 is a non-conformal coated assembly. For deployment in environments with corrosive atmospheric contaminants, specifying the conformal coated alternative (CC-TAIX11) is required to meet ISA G3 standards. This termination assembly is designed specifically to host the CC-PAIX01 or CC-PAIX02 active Series C modules and cannot accept Series A or other legacy input modules.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen mixing 2-wire (loop-powered) and 4-wire (externally-powered) instruments on the same assembly, incorrect grounding can lead to common-mode voltage saturation. For 4-wire configurations, ensure that signal-minus (-) paths are not left floating; connect them directly to the common ground plane of the enclosure power supply to prevent erroneous drift readings.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo eliminate high-frequency electromagnetic noise interference, always terminate the shielding drain wire of input cables on the dedicated chassis ground bus of the CC-TAIX01 IOTA. Never ground the shield at both the field transmitter end and the IOTA termination end simultaneously, as this can introduce destructive ground loops.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Field Deployment Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eIsolate and lock out all auxiliary 24 VDC power networks prior to mounting or completing any wiring terminations on the assembly. Hot-wiring transmitter loops on an energized assembly can blow on-board terminal protective fuses or disrupt active controller communication backplanes.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"flex-grow: 1; color: #2d3748; padding-top: 2px;\"\u003eMount the CC-TAIX01 board directly onto the 35mm DIN rail inside the enclosure, ensuring the carrier locks are fully engaged.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"flex-grow: 1; color: #2d3748; padding-top: 2px;\"\u003eConnect the system safety ground strap to the designated low-impedance ground point on the carrier.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"flex-grow: 1; color: #2d3748; padding-top: 2px;\"\u003eRoute field cables through clean, non-obstructive wiring ducts and strip lead wires back exactly 7 mm before inserting into the clamp terminals.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"flex-grow: 1; color: #2d3748; padding-top: 2px;\"\u003eTorque the terminal clamp screws to a maximum rating of 0.5 Nm to prevent physical thread damage on the termination block.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705606566251,"sku":"CC-TAIX01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-TAIX01-2cwayh0lfmg_a3b74919-945a-4f45-aaee-b8f625424ff2.jpg?v=1766651507","url":"https:\/\/www.plcprotech.com\/ms\/products\/honeywell-cc-taix01-experion-c300-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}