{"product_id":"honeywell-tk-ffif01-c200-fieldbus-interface-module","title":"Honeywell TK-FFIF01 C200 Fieldbus Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTK-FFIF01\u003c\/strong\u003e is a chassis-mounted communication interface component operating as a \u003cstrong\u003eFieldbus Interface Module\u003c\/strong\u003e (FIM2) within the Honeywell C200 and Experion distributed control system (DCS) architectures. This device establishes deterministic data highways between the host controller backplane and field-level instruments executing decentralized control strategies. Equipped with two independent, digital communication links, it handles token passing, schedule execution, and diagnostic frame transmission across standard industrial networks. The module is built with conformally coated electronic assemblies to resist atmospheric contamination and humidity, ensuring reliable digital network integration and continuous parameter exchange for intelligent field instrumentation in processing environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual independent communication links for field-level network routing.\u003c\/li\u003e\n\u003cli\u003eConformal coating protection on internal circuit boards to withstand harsh environments.\u003c\/li\u003e\n\u003cli\u003eSpecialized CIOM-A hardware platform form factor for direct rack integration.\u003c\/li\u003e\n\u003cli\u003eReal-time diagnostic data tracking and status mapping to master controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntelligent field device configuration and monitoring in process loops.\u003c\/li\u003e\n\u003cli\u003eDistributed Control Systems (DCS) digital network communication bridging.\u003c\/li\u003e\n\u003cli\u003eInstrumentation mapping inside chemical, oil and gas, and wastewater facilities.\u003c\/li\u003e\n\u003cli\u003eAsset management integration utilizing digital field network diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-FFIF01 (Product text reference: TK-FFIFF01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFieldbus Interface Module (FIM2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eC200 Chassis I\/O (CIOM-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Links\u003c\/td\u003e\n\u003ctd\u003e2 Links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Protection\u003c\/td\u003e\n\u003ctd\u003eCoated (Conformal Coating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.42 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ Global Operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cp\u003eEnsure the host C200 chassis is bonded directly to the primary industrial instrumentation grounding bus using a low-impedance copper conductor. Field network cable shields must follow strict segment termination protocols, grounding at designated external terminal blocks to suppress cross-talk and high-frequency noise.\u003c\/p\u003e\n\u003ch3\u003eHandling and ESD Protection\u003c\/h3\u003e\n\u003cp\u003eThe internal communication circuitry is susceptible to electrostatic discharge. Field technicians must utilize an approved, bonded static-dissipative wrist strap during unboxing, address selection, or final installation into the controller chassis slot.\u003c\/p\u003e\n\u003ch3\u003eAlignment and Insertion\u003c\/h3\u003e\n\u003cp\u003eAlign the circuit card edges with the molded plastic chassis tracks. Slide the module completely into the assigned backplane connector slot until the latching mechanism is fully engaged, and secure the mechanical fasteners to maintain proper contact pressure under continuous operational vibration.\u003c\/p\u003e\n\u003ch3\u003eEnvironmental Considerations\u003c\/h3\u003e\n\u003cp\u003eThe module features a conformal coating layer for improved defense against corrosive atmospheres. Ensure ventilation spaces inside the enclosure remain clean and unblocked to prevent regional temperature spikes from exceeding standard system operating parameters.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core purpose of this interface module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt functions as a communication gateway bridging the central controller backplane with field-level digital instruments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many network lines can a single hardware assembly manage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is designed with two distinct links to coordinate digital device loops independently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the term coated mean in the technical details?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt indicates the internal printed circuit boards feature a conformal coating layer to shield components against humidity and airborne contaminants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this device compatible with standard C200 chassis hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is designed with the standard CIOM-A form factor for seamless slot insertion into compatible racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the net physical weight of this standalone unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe individual unboxed module has a net physical weight of exactly 0.42 Kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this component operate as a standalone process loop controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it is a dedicated communication interface module that routes digital field parameters back to a master controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions are necessary regarding static electricity when handling this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians must follow proper ESD control protocols, including using grounded wrist straps, before executing maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware package include external terminal blocks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe base module fits into standard rack backplanes; external wiring connectors must be sourced separately based on physical architecture layouts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the hardware protected against physical movement within the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt uses standard mechanical retention locks that clamp directly onto the chassis faceplate assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the total mass of the module inside its standard transport packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe complete shipping weight including the protective outer carton is specified at 1.5 Kg.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705305559403,"sku":"TK-FFIF01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TK-FFIFF01-xrpsv0yjmmk_9b56e525-e8d0-455a-b48a-c6c95d3a50a4.jpg?v=1766639353","url":"https:\/\/www.plcprotech.com\/ms\/products\/honeywell-tk-ffif01-c200-fieldbus-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}