{"product_id":"honeywell-tk-fxx102-c200-10-slot-chassis-rack","title":"Honeywell TK-FXX102 C200 10-Slot Chassis Rack","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTK-FXX102\u003c\/strong\u003e is a rugged, heavy-duty structural hardware component configured as a \u003cstrong\u003e10-Slot Rack\u003c\/strong\u003e (Chassis) within the Honeywell C200 and Experion distributed control system (DCS) architectures. This chassis serves as the central physical and electrical backbone for the C200 system, providing 10 dedicated hardware slots to house control processors, power supplies, redundancy modules, communication gateways, and high-density I\/O modules (CIOM-A). Built with an integrated multi-tier backplane printed circuit board, it provides deterministic data routing paths and stabilized DC power distribution lines across all inserted modules. Its robust mechanical frame is designed for standard panel or enclosure mounting, ensuring safe electrical isolation, structural alignment, and resistance to harsh environmental stresses in critical process plant installations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10 high-integrity module slots providing uniform layout flexibility and expansion capabilities.\u003c\/li\u003e\n\u003cli\u003eIntegrated passive backplane layout ensuring reliable, deterministic cross-module communications.\u003c\/li\u003e\n\u003cli\u003eRigid industrial-grade metal casing designed to prevent twisting and misalignment under mechanical stress.\u003c\/li\u003e\n\u003cli\u003eDual-point grounding pathways engineered to secure logic-tier electronics against high-frequency transients.\u003c\/li\u003e\n\u003cli\u003eStandardized pre-drilled mounting tabs for direct fastening into equipment control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentralized housing for primary and redundant C200 process controller setups.\u003c\/li\u003e\n\u003cli\u003eLocal and remote I\/O chassis grouping for distributed plant data acquisition loops.\u003c\/li\u003e\n\u003cli\u003eSystem infrastructure grouping inside chemical, petroleum, and pharmaceutical control rooms.\u003c\/li\u003e\n\u003cli\u003eMain chassis backplane installation within power generation and utility automation panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-FXX102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e10-Slot Rack (Chassis Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eC200 \/ Experion System Infrastructure (CIOM-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Available Slots\u003c\/td\u003e\n\u003ctd\u003e10 Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical slot alignment, horizontal panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ Global Operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003ePanel Mounting and Dimensions\u003c\/h3\u003e\n\u003cp\u003eFix the chassis rack inside the industrial enclosure using standard heavy-duty fasteners through all pre-drilled flange holes. Confirm the mounting plane is completely flat and level to prevent any tortional twisting of the frame, which can stress the backplane motherboard or lead to loose module guide tracking.\u003c\/p\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cp\u003eSecurely attach a thick, low-impedance copper ground strap from the designated grounding studs on the chassis frame directly to the master instrumentation earth bus bar. Proper grounding is critical to guarantee electrical shield continuity and protect backplane logic lines from external electromagnetic field interference.\u003c\/p\u003e\n\u003ch3\u003eCooling and Ventilation\u003c\/h3\u003e\n\u003cp\u003eLeave a minimum unobstructed clearance of at least 5 to 10 cm above and below the chassis rack assembly inside the enclosure panel. This safety margin facilitates proper natural convection or forced-air cooling, preventing trapped hot air from raising the internal temperatures of the operating modules.\u003c\/p\u003e\n\u003ch3\u003eModule Insertion and Alignment\u003c\/h3\u003e\n\u003cp\u003eBefore inserting any control module, inspect the slot tracks and backplane pin connectors to confirm they are clear of dirt or debris. Slide the module cards smoothly along the upper and lower plastic tracks until they are fully seated into the rear backplane receptacles, then hand-tighten the integrated faceplate retaining screws.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core function of the 10-slot rack assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides the physical framing, guide slots, and electrical backplane connectivity required to house and link C200 system modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan a standard power supply module be mounted directly inside this chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, specific slots on the backplane are designed to accept and route power directly from compatible C200 power supply units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this rack assembly compatible with modern Experion I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it features the native CIOM-A form factor built explicitly for C200 controllers and associated chassis-based I\/O components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the gross package weight when boxed for bulk delivery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe estimated shipping weight of the chassis unit within its protective transport carton is rated at 2.5 Kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this chassis incorporate active cooling fans on the backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it is a passive mechanical rack that relies on proper panel ventilation spacing and ambient convection air patterns.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module address or slot number determined inside this rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe slot positions are numbered sequentially from left to right along the backplane, and the system software references these physical locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan multiple chassis racks be linked together in a single system panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, multiple racks can be networked using compatible ControlNet interface modules or specialized link cables to expand I\/O capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should be taken concerning backplane connection pins during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNever force a module into a slot if resistance is encountered; inspect for bent alignment pins or tracking block obstacles first.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre special mounting brackets needed to fit this unit into standard industrial cabinets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe rack frame is engineered with built-in side flanges that allow direct bolting to standard layout panels without extra hardware kits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should static electricity be managed when interacting with an unpopulated rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways wear an active, grounded anti-static wrist strap before touching backplane connectors or inserting circuit cards to avoid ESD damage.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705313456491,"sku":"TK-FXX102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tk-fxx102-lttvhirq2je_ccff9ffd-ca4d-4bcb-94df-7219625d06b6.jpg?v=1766639572","url":"https:\/\/www.plcprotech.com\/ms\/products\/honeywell-tk-fxx102-c200-10-slot-chassis-rack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}