{"product_id":"kl2641-beckhoff-bus-terminal-relay-output-module","title":"KL2641 | BECKHOFF | Bus Terminal Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eKL2641\u003c\/strong\u003e is a high-performance \u003cstrong\u003eBus Terminal\u003c\/strong\u003e from \u003cstrong\u003eBeckhoff\u003c\/strong\u003e featuring a \u003cstrong\u003e1-channel relay output\u003c\/strong\u003e designed for heavy-duty switching applications. This module incorporates a \u003cstrong\u003ebistable relay contact\u003c\/strong\u003e, which retains its state without continuous power consumption for the coil, providing significant energy efficiency and reliability. The terminal is equipped with manual operation capabilities, allowing for direct override of the relay contact, and includes two inputs for monitoring manual and automatic status. It is engineered to handle up to \u003cstrong\u003e16 A\u003c\/strong\u003e switching current, making it ideal for controlling ohmic, inductive, and lamp loads in industrial automation systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-channel relay output (make contact)\u003c\/li\u003e\n\u003cli\u003eHigh switching capacity up to 5 kVA\u003c\/li\u003e\n\u003cli\u003eIntegrated manual operation switch for testing and override\u003c\/li\u003e\n\u003cli\u003eBistable relay contact design for reduced power consumption\u003c\/li\u003e\n\u003cli\u003eStatus monitoring for manual and automatic operation states\u003c\/li\u003e\n\u003cli\u003eRobust contact material (AgSnO2) for extended durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBeckhoff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKL2641\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC (max. 440 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Switching Capacity\u003c\/td\u003e\n\u003ctd\u003e5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output\/Switching Current\u003c\/td\u003e\n\u003ctd\u003e16 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eAgSnO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Cycles (Mech.)\u003c\/td\u003e\n\u003ctd\u003e1 x 10^6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (K-bus)\u003c\/td\u003e\n\u003ctd\u003eTyp. 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (Power Contacts)\u003c\/td\u003e\n\u003ctd\u003eTyp. 65 mA + load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 110 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The \u003cstrong\u003eKL2641\u003c\/strong\u003e is designed for integration into standard DIN rail assemblies. Ensure the module is securely locked into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Given the high current capacity (16 A), ensure all wiring uses appropriate gauge cables to prevent overheating. Follow local electrical safety codes for 230 V AC \/ 440 V AC circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Override:\u003c\/strong\u003e Use the manual operation feature cautiously during system maintenance to avoid unexpected equipment activation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e The unit is IP20 rated. It must be installed in a protected control cabinet to prevent exposure to conductive dust, moisture, or extreme environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106588942699,"sku":"KL2641","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl2641-0pdrqyyfcy0.png?v=1776245138","url":"https:\/\/www.plcprotech.com\/ms\/products\/kl2641-beckhoff-bus-terminal-relay-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}