{"product_id":"mitsubishi-electric-aj65bt-64rd3-cc-link-temperature-input-unit","title":"Mitsubishi Electric AJ65BT-64RD3 CC-Link Temperature Input Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFor highly precise thermal monitoring within automated industrial environments, the \u003cstrong\u003eAJ65BT-64RD3\u003c\/strong\u003e serves as an industrial-grade platinum resistance temperature detector (RTD) input module. This remote device station interfaces directly with CC-Link networks, allowing seamless integration of temperature sensor telemetry into central PLC and DCS systems.\u003c\/p\u003e\n\n\u003cp\u003eThe module supports four independent 3-wire RTD input channels compatible with standard Pt100 and JPt100 sensors. It translates raw analog sensor signals into either 16-bit or high-resolution 32-bit signed binary values, ensuring precise digital conversion. Electrical isolation via internal photocouplers isolates the sensor input circuitry from the CC-Link communication line, safeguarding the network from common-mode voltage spikes and electromagnetic noise.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports up to 4 independent 3-wire RTD channels (Pt100 and JPt100 compatibility).\u003c\/li\u003e\n  \u003cli\u003eFast conversion speed of 40 ms per channel for real-time monitoring.\u003c\/li\u003e\n  \u003cli\u003eFlexible digital output configuration with 16-bit or 32-bit signed binary modes.\u003c\/li\u003e\n  \u003cli\u003eHigh-integrity photocoupler isolation between the sensor inputs and the CC-Link transmission system.\u003c\/li\u003e\n  \u003cli\u003eRemovable 2-piece terminal block interfaces (7-point and 27-point M3.5 screw terminals) to simplify field wiring and module replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal monitoring of industrial furnaces and ovens.\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical process temperature tracking.\u003c\/li\u003e\n  \u003cli\u003eHVAC, refrigeration, and cooling system management.\u003c\/li\u003e\n  \u003cli\u003ePower generation plant turbine and bearing temperature diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAJ65BT-64RD3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCC-Link RTD Temperature Input Unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCompatible Sensors\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePt100, JPt100 (3-wire type)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-180 to 600 degC (both Pt100 and JPt100)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.025 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAccuracy (25 degC +\/- 5 degC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/- 0.1% of full scale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAccuracy (0 to 55 degC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/- 0.25% of full scale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e40 ms \/ channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCC-Link Station Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRemote Device Station (Ver.1, occupies 4 stations)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIsolation Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePhotocoupler isolation (between inputs and CC-Link line; non-isolated between channels)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 VAC for 1 minute (between power, communication, input, and ground terminals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 MOhm or more (at 500 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 VDC (18 to 30 VDC allowable), 0.17 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7-point terminal block (M3.5 screws) for power and CC-Link; 27-point terminal block (M3.5 screws) for sensor I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-20 to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmbient Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 to 90% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e65 mm x 151.9 mm x 63 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.38 kg (Shipping Weight: 1.4 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInstall the module inside a clean, dust-free industrial control cabinet rated for IP54 or higher.\u003c\/li\u003e\n  \u003cli\u003eEnsure the system is completely powered down before connecting or disconnecting the CC-Link cable and RTD wiring.\u003c\/li\u003e\n  \u003cli\u003eUtilize CC-Link dedicated cabling to ensure signal integrity across the fieldbus network.\u003c\/li\u003e\n  \u003cli\u003eGround the shielded wire of the CC-Link cable and connect the module's ground terminal to a low-impedance ground point.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum clearance around the module to allow proper heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102141014379,"sku":"AJ65BT-64RD3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/AJ65BT-64RD3-ykqifag3doz.png?v=1776137227","url":"https:\/\/www.plcprotech.com\/ms\/products\/mitsubishi-electric-aj65bt-64rd3-cc-link-temperature-input-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}