{"product_id":"omron-e5ak-aa2-500-e5ak-series-digital-controller","title":"Omron E5AK-AA2-500 E5AK Series Digital Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eE5AK-AA2-500\u003c\/strong\u003e is an industrial-grade, 1\/4 DIN digital process controller engineered by Omron for highly accurate temperature and process regulation. This standard model features a 96 × 96 mm front panel design and comes equipped with a rear terminal cover to protect electrical connections from accidental contact. Offering exceptional flexibility, the Omron \u003cstrong\u003eE5AK-AA2-500\u003c\/strong\u003e controller is built with a modular structure that accepts various plug-in output units, allowing seamless integration into diverse automation control architectures.\u003c\/p\u003e\n\n\u003cp\u003eEquipped with two independent built-in alarms, this digital controller provides crucial system monitoring, status signaling, and safety shutdowns. The dual-display interface provides simultaneous feedback of both the Process Value (PV) and Set Value (SV), allowing operators to monitor thermal systems, environmental chambers, and packaging lines in real time with high visual clarity.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStandard 1\/4 DIN panel size (96 × 96 mm) for straightforward integration into control panels.\u003c\/li\u003e\n  \u003cli\u003eIncludes factory-supplied rear terminal cover to enhance electrical safety and prevent short circuits.\u003c\/li\u003e\n  \u003cli\u003eEquipped with two independent, configurable alarm outputs for system status and threshold monitoring.\u003c\/li\u003e\n  \u003cli\u003eDual high-visibility digital display showing Process Value (PV) and Set Value (SV) simultaneously.\u003c\/li\u003e\n  \u003cli\u003eModular design supporting interchangeable plug-in output units to meet specific application needs.\u003c\/li\u003e\n  \u003cli\u003eRobust housing design suitable for demanding industrial environmental conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal processing and industrial baking ovens.\u003c\/li\u003e\n  \u003cli\u003ePlastic extrusion and injection molding machines.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and heat-sealing equipment.\u003c\/li\u003e\n  \u003cli\u003eHVAC and environmental simulation chambers.\u003c\/li\u003e\n  \u003cli\u003eChemical and food processing control loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE5AK-AA2-500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE5AK\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDigital Controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eController Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4 DIN (96 × 96 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Variant\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard Model\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Alarms\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Cover\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e96 mm x 96 mm x 113.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 kg (approximate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePrepare a standard 1\/4 DIN panel cutout measuring approximately 92 × 92 mm.\u003c\/li\u003e\n  \u003cli\u003eInsert the controller through the panel front and secure it firmly using the provided mounting brackets.\u003c\/li\u003e\n  \u003cli\u003eEnsure the rear terminal cover is correctly snapped into place after completing all wiring connections.\u003c\/li\u003e\n  \u003cli\u003eRoute all sensor input signals separately from high-voltage AC power lines to avoid electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eProvide adequate ventilation behind the panel to ensure ambient operating temperatures do not exceed recommended limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077915599211,"sku":"E5AK-AA2-500","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e5ak-aa2-500-0m4j3udqkou.png?v=1775733738","url":"https:\/\/www.plcprotech.com\/ms\/products\/omron-e5ak-aa2-500-e5ak-series-digital-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}