{"product_id":"omron-e5cc-cx3a5m-004-e5cc-digital-temperature-controller","title":"Omron E5CC-CX3A5M-004 E5CC Digital Temperature Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003ePrecision thermal loop management is achieved through the \u003cstrong\u003eOmron E5CC-CX3A5M-004\u003c\/strong\u003e, a compact 48 x 48 mm (1\/16 DIN) \u003cstrong\u003edigital temperature controller\u003c\/strong\u003e engineered for high-speed, stable PID execution. Featuring a high-contrast white LCD display with 15.2 mm character height, this controller ensures clear process value (PV) visibility even in low-light industrial environments. It supports high-speed sampling at 50 ms, allowing immediate response to thermal fluctuations in demanding closed-loop systems.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features a universal input structure, allowing seamless connection of various thermocouples, RTDs, or analog voltage\/current sensors without requiring hardware modifications. It is equipped with a linear current control output, three auxiliary outputs, and an integrated RS-485 communications interface, making it an excellent node for distributed control architectures using PLC or SCADA supervisory systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Sensor Input:\u003c\/strong\u003e Direct connection for standard thermocouples, platinum resistance thermometers (RTD), and analog current\/voltage signals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Control Loop:\u003c\/strong\u003e Fast 50 ms sampling period provides rapid feedback processing for dynamic thermal systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLinear Current Output:\u003c\/strong\u003e Dedicated analog control output (4-20 mA or 0-20 mA) for modulation of SCR power controllers, control valves, or variable speed drives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Connectivity:\u003c\/strong\u003e Integrated RS-485 serial communication port supporting Modbus\/RTU and CompoWay\/F protocols for PLC integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiple Event Inputs:\u003c\/strong\u003e Includes two digital event inputs for remote operation, run\/stop toggling, or multi-SP selection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuxiliary Outputs:\u003c\/strong\u003e Three independent relay outputs sharing a common terminal, configurable for various alarm types and status outputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Construction:\u003c\/strong\u003e Standard screw terminal connection block supplied with a protective terminal cover.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePlastic extrusion and injection molding temperature control.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery, shrink tunnels, and heat sealing systems.\u003c\/li\u003e\n  \u003cli\u003eIndustrial heat treatment furnaces, kilns, and drying ovens.\u003c\/li\u003e\n  \u003cli\u003eFood processing machinery, pasteurizers, and industrial fryers.\u003c\/li\u003e\n  \u003cli\u003eEnvironmental chambers and laboratory testing equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eE5CC-CX3A5M-004\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003eE5CC Series (48 x 48 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\n      \u003ctd\u003e100 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\n      \u003ctd\u003e85% to 110% of rated voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Consumption\u003c\/strong\u003e\n      \u003ctd\u003eMax. 5.2 VA (100 to 240 VAC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Type\u003c\/strong\u003e\n      \u003ctd\u003eUniversal input (Thermocouple, RTD, Analog current\/voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eControl Output 1\u003c\/strong\u003e\n      \u003ctd\u003eLinear current output (4 to 20 mA DC \/ 0 to 20 mA DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eControl Output 2\u003c\/strong\u003e\n      \u003ctd\u003eNone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAuxiliary Outputs\u003c\/strong\u003e\n      \u003ctd\u003e3 relay outputs (SPST-NO, sharing one common line)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCommunications Interface\u003c\/strong\u003e\n      \u003ctd\u003eRS-485 (2-wire, half-duplex)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eEvent Inputs\u003c\/strong\u003e\n      \u003ctd\u003e2 contact inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTerminal Type\u003c\/strong\u003e\n      \u003ctd\u003eScrew terminals (with terminal cover)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eIndication Accuracy\u003c\/strong\u003e\n      \u003ctd\u003eThermocouple: +\/-0.3% of PV; RTD: +\/-0.2% of PV; Analog: +\/-0.2% FS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-10 to 55 degC (with no condensation or icing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAmbient Operating Humidity\u003c\/strong\u003e\n      \u003ctd\u003e25% to 85% RH\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.13 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Group\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Terminals\u003c\/td\u003e\n      \u003ctd\u003e100 to 240 VAC line input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Output 1\u003c\/td\u003e\n      \u003ctd\u003eLinear current output terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Outputs 1, 2, 3\u003c\/td\u003e\n      \u003ctd\u003eThree outputs sharing a single common terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Input Terminals\u003c\/td\u003e\n      \u003ctd\u003eConfigurable wiring for RTD (A, B, B), Thermocouple (+, -), or Analog input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRS-485 Communication Port\u003c\/td\u003e\n      \u003ctd\u003eTwo-wire communication connections (A and B)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEvent Inputs 1 and 2\u003c\/td\u003e\n      \u003ctd\u003eNo-voltage digital contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Install into a standard 45 x 45 mm square panel cutout. Slide the mounting adapter over the controller from the rear and tighten until secure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Isolation:\u003c\/strong\u003e Maintain separation between input sensor signal wiring, communication cables, and high-voltage power lines to reduce electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient Environment:\u003c\/strong\u003e Ensure the installation area remains within the operating limit of -10 to 55 degC, and maintain sufficient ventilation space around the controller.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Protection:\u003c\/strong\u003e Securely attach the provided screw terminal cover to prevent accidental contact with live electrical lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark\u003c\/li\u003e\n  \u003cli\u003eUL Listed \/ cULus\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077926969707,"sku":"E5CC-CX3A5M-004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e5cc-cx3a5m-004-0jopd5owtsq.png?v=1775733746","url":"https:\/\/www.plcprotech.com\/ms\/products\/omron-e5cc-cx3a5m-004-e5cc-digital-temperature-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}