{"product_id":"omron-nx701-1620-nx7-motion-controller","title":"Omron NX701-1620 NX7 Motion Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDelivering rapid processing capabilities for high-performance automation, the Omron NX701-1620 provides execution of complex motion and database logging algorithms directly within the controller core. This heavy-duty system controller acts as the central command unit for large-scale production facilities, synchronizing high-speed sequence programs and multi-axis trajectory profiles. By integrating native \u003cstrong\u003edirect SQL database connectivity\u003c\/strong\u003e and an embedded \u003cstrong\u003eOPC-UA server\u003c\/strong\u003e, it bridges the gap between the plant floor and IT-level enterprise systems without requiring gateway PCs or specialized middleware.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eDirect synchronization of up to \u003cstrong\u003e128 physical motion axes\u003c\/strong\u003e for complex electronic gearing and camming applications.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eUltra-fast cycle execution with a primary task cycle time of \u003cstrong\u003e0.125 ms\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eEmbedded DB client function enables real-time logging to Microsoft SQL, Oracle, MySQL, PostgreSQL, and Firebird servers.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eBuilt-in industrial network protocols including \u003cstrong\u003eEtherCAT Master\u003c\/strong\u003e and dual \u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e ports.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMassive memory allocation with 80 MB program capacity and 260 MB variables memory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-speed rotary packaging and form-fill-seal lines.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMulti-axis robotic handling and assembly cells.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eTraceability-heavy pharmaceutical or automotive assembly lines requiring direct database tracking.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-precision semiconductor fabrication tool automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNX701-1620\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eController Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSysmac NX7\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eTask Cycle Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.125 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eProgram Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e80 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eVariables Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e260 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eMax. Controlled Axes\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e128 Synchronous Axes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eCommunication Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eEtherCAT (Master), EtherNet\/IP (2 Ports), Ethernet TCP\/IP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eLocal I\/O Bus\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNX I\/O Bus System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.88 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInterface Port\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunctional Protocol Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003ePort 1 (EtherNet\/IP)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHost communications, HMI interface, Tag Data Link networking, Sysmac Studio tool interface.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003ePort 2 (EtherNet\/IP)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSecondary industrial network ring, direct SQL client execution, or OPC-UA server communications.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003ePort 3 (EtherCAT)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDeterministic servo drive control, distributed I\/O couplers, high-speed remote nodes.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eSD Card Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLogging spools, memory card storage, OS firmware updates, and system recovery.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe NX701-1620 is configured within the Sysmac Studio platform. It replaces smaller controllers like the NX701-1600 (which is limited to 64 axes) in scenarios where mechanical expansions demand increased servo synchronization. Ensure that all program files are recompiled in Sysmac Studio version 1.10 or higher when converting code from older NX-series platforms.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing the direct SQL connection feature, ensure your database spooling configuration is active. If the destination database server goes offline, the controller utilizes internal memory blocks as a buffer. If the outage exceeds the buffer capacity, data overwrite warnings occur. Always set up appropriate diagnostic alarms to monitor SQL transaction queues.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eHigh-density multi-axis EtherCAT loops require high-quality STP Cat5e (or better) industrial Ethernet cables. Poorly shielded or loose cabling will introduce microsecond jitter, resulting in intermittent packet loss and subsequent controller axis synchronization faults. Route network communication wires away from high-power servo motor cables.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all primary and auxiliary 24 VDC power supplies before mounting, demounting, or wiring the controller. Failure to disconnect power during installation can lead to internal circuit damage, arc-flashes, or unexpected equipment movement.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eAlign the back DIN rail hook of the controller onto the standard 35 mm DIN track, pushing until it clicks securely into place.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSecurely connect the functional ground wire to a low-impedance grounding point, ensuring adequate noise immunity.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWire the designated 24 VDC power supply to the unit's supply terminals, verifying correct polarity before applying power.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077899641195,"sku":"NX701-1620","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx701-1620-zk2oq01zcsc.png?v=1775734048","url":"https:\/\/www.plcprotech.com\/ms\/products\/omron-nx701-1620-nx7-motion-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}