{"product_id":"siemens-6av3607-7jc20-1aq0-simatic-hmi-op7-operator-panel","title":"Siemens 6AV3607-7JC20-1AQ0 SIMATIC HMI OP7 Operator Panel","description":"\u003cp\u003eThe \u003cstrong\u003e6AV3607-7JC20-1AQ0\u003c\/strong\u003e is a specialized \u003cstrong\u003eSIMATIC HMI OP7\u003c\/strong\u003e handheld operator panel, engineered for flexible, mobile control of industrial automation systems. This ruggedized \u003cstrong\u003ehandheld housing\u003c\/strong\u003e unit comes equipped with a 2.5-meter connection cable and features two integrated pushbuttons, allowing for ergonomic manual control directly at the point of operation. Designed for integration into PROFIBUS\/MPI networks, this device provides a reliable human-machine interface for machine monitoring and parameter adjustment in constrained spaces.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SIMATIC HMI OP7 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e Handheld unit with ergonomic housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Includes a 2.5m cable with an integrated Euchner connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Elements:\u003c\/strong\u003e 2 physical pushbuttons for direct operator interaction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e MPI communication capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e Obsolete\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMobile machine diagnostic and maintenance tasks\u003c\/li\u003e\n\u003cli\u003eManual setup and positioning of motion axes\u003c\/li\u003e\n\u003cli\u003eEmergency interaction points in robotic cells (Note: This specific model does not feature an Emergency-Off button)\u003c\/li\u003e\n\u003cli\u003eDecentralized monitoring of production lines\u003c\/li\u003e\n\u003cli\u003eTroubleshooting in confined industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6AV3607-7JC20-1AQ0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eSIMATIC HMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003eOP7 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eEuchner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePushbuttons\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency-Off\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.70 x 19.50 x 8.90 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e The \u003cstrong\u003eEuchner connector\u003c\/strong\u003e must be securely mated to the corresponding industrial receptacle. Ensure the locking mechanism is fully engaged to prevent intermittent signal loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Use proper strain relief for the 2.5m cable to prevent damage to the internal wiring or the connector housing during routine mobile use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e While designed for industrial use, ensure the handheld housing is stored in a clean, dry location when not in use to maintain the integrity of the keypad and display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the machine-side receptacle is properly grounded to maintain signal integrity for the MPI interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Safety:\u003c\/strong\u003e Since this unit lacks an emergency-off button, ensure that all critical safety stops are managed by independent, hardwired safety circuits elsewhere on the machine.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716787138923,"sku":"6AV3607-7JC20-1AQ0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av3607-7jc20-1aq0-35t0t5y0fo0_b8deb685-2ff2-4d8c-a66d-71a04bd58349.jpg?v=1767089785","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-6av3607-7jc20-1aq0-simatic-hmi-op7-operator-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}