{"product_id":"siemens-6av7705-1dc10-0ad0-simatic-panel-pc-870","title":"Siemens 6AV7705-1DC10-0AD0 SIMATIC Panel PC 870","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens SIMATIC Panel PC 870, model \u003cstrong\u003e6AV7705-1DC10-0AD0\u003c\/strong\u003e, configured as a standard industrial human-machine interface (HMI) terminal. It is equipped with a \u003cstrong\u003e15.1-inch color TFT display\u003c\/strong\u003e, a \u003cstrong\u003ePentium III 1.26 GHz processor\u003c\/strong\u003e, and \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e. The unit includes a \u003cstrong\u003e40 GByte EIDE hard drive\u003c\/strong\u003e and a CD-ROM drive, with Windows 2000 Multi-Language pre-installed. It is designed for 230V AC operation and includes a mains cable with a European plug.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003e15.1-inch Color TFT Display\u003c\/li\u003e\n  \u003cli\u003eIntel Pentium III 1.26 GHz Processor\u003c\/li\u003e\n  \u003cli\u003e128 MByte RAM\u003c\/li\u003e\n  \u003cli\u003e40 GByte EIDE Hard Disk Drive\u003c\/li\u003e\n  \u003cli\u003eIntegrated CD-ROM Drive\u003c\/li\u003e\n  \u003cli\u003ePre-installed Windows 2000 Multi-Language Operating System\u003c\/li\u003e\n  \u003cli\u003eDesigned for 230V AC power input\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) for process control\u003c\/li\u003e\n  \u003cli\u003eSCADA client nodes\u003c\/li\u003e\n  \u003cli\u003eIndustrial data logging and visualization\u003c\/li\u003e\n  \u003cli\u003eMachine-level control and monitoring stations\u003c\/li\u003e\n  \u003cli\u003eFactory automation control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left; background-color: #f4f4f4; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left; background-color: #f4f4f4; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e6AV7705-1DC10-0AD0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eSIMATIC Panel PC 870\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003ePanel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e15.1-inch Color TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003ePentium III 1.26 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e128 MByte\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e40 GByte HDD EIDE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eCD-ROM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eWindows 2000 Multi-Language (EN, GER, FR, IT, SP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eInput Power\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e230V AC (with European plug)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e19.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e61.00 x 59.00 x 35.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation, wiring, and maintenance must be performed only by qualified personnel. Failure to de-energize the system and follow Lockout\/Tagout (LOTO) procedures before servicing can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before installation, completely disconnect and lock out all power sources to the control cabinet or panel where the PC will be installed. Verify the absence of voltage with a properly rated meter.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003ePanel Cutout and Mounting:\u003c\/strong\u003e Prepare the panel cutout according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and can support the weight of the unit. Secure the Panel PC into the cutout using all provided mounting clamps, tightening them evenly to ensure a proper seal.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eProtective Earth (PE) Connection:\u003c\/strong\u003e Connect a low-impedance protective earth conductor to the designated PE terminal on the Panel PC chassis. This connection is critical for safety and noise immunity and must be established before any other connections are made.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003ePower and I\/O Wiring:\u003c\/strong\u003e Connect the 230V AC mains cable to a properly fused and protected power source. Connect all communication and I\/O cables. Route cables away from high-voltage lines and sources of electromagnetic interference (EMI) to prevent signal degradation.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections are secure and correct, remove LOTO devices and re-apply power to the cabinet. Observe the Panel PC during its boot sequence to ensure the operating system loads correctly and there are no hardware faults.\u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715860656491,"sku":"6AV7705-1DC10-0AD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7705-1dc10-0ad0-lxqixdjfjxw_70348832-fccd-4dd0-afc7-a1a77fc60012.jpg?v=1767073011","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-6av7705-1dc10-0ad0-simatic-panel-pc-870","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}