{"product_id":"siemens-6av7724-1bb10-0ad0-simatic-panel-pc-670","title":"Siemens 6AV7724-1BB10-0AD0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis device is a Siemens 6AV7724-1BB10-0AD0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This standard configuration features a \u003cstrong\u003e15.1-inch color TFT touchscreen\u003c\/strong\u003e display, powered by a \u003cstrong\u003ePentium III 1.26 GHz\u003c\/strong\u003e processor. It is equipped with \u003cstrong\u003e128 MB of SDRAM\u003c\/strong\u003e, a \u003cstrong\u003e40 GB EIDE hard drive\u003c\/strong\u003e for local data storage, and a DVD-ROM drive. The unit is pre-installed with the Windows 2000 Multi-Language operating system and includes a power supply box rated for 115-230V AC input.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e15.1-inch color TFT touchscreen display for operator interaction.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Intel Pentium III processor operating at 1.26 GHz.\u003c\/li\u003e\n  \u003cli\u003e128 MB of SDRAM-133 system memory.\u003c\/li\u003e\n  \u003cli\u003e40 GByte EIDE hard disk drive for operating system and application storage.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in DVD-ROM optical drive.\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows 2000 Multi-Language edition.\u003c\/li\u003e\n  \u003cli\u003eIncludes a power supply box for 115-230V AC operation with a US mains cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eMachine control and monitoring\u003c\/li\u003e\n  \u003cli\u003eProcess visualization (SCADA\/HMI)\u003c\/li\u003e\n  \u003cli\u003eData logging and acquisition\u003c\/li\u003e\n  \u003cli\u003eFactory floor operator stations\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e6AV7724-1BB10-0AD0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePanel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e15.1-inch Color TFT, Touch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePentium III, 1.26 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eMemory\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e128 MB SDRAM-133 (1x128MB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e40 GByte HDD EIDE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDVD-ROM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eWindows 2000 Multi-Language\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e115-230V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e12.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e48.0 x 29.0 x 15.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens AG\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical hazard. Disconnect and lock out all power sources before installation or servicing. Installation must be performed by qualified personnel familiar with industrial control panel standards and practices. Failure to comply can result in severe injury or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eEnsure the mounting cutout in the control panel is clean, deburred, and matches the specified dimensions for the PC 670. Verify that the panel surface is flat to ensure a proper seal.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eInsert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a diagonal pattern to the manufacturer-specified torque to ensure uniform gasket compression.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eConnect a dedicated protective earth (PE) or grounding conductor to the designated grounding terminal on the PC chassis. This connection is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eConnect the AC power supply cable to the unit's power input. Ensure the source voltage (115-230V AC) matches the power supply rating. Route power cables separately from signal and communication cables.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eConnect all required communication, I\/O, and peripheral cables. Ensure all connectors are fully seated and secured. After all connections are made, restore power to the panel and verify correct system boot-up.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715872420203,"sku":"6AV7724-1BB10-0AD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7724-1bb10-0ad0-tag5bfj1e2g_ffeeb0ac-85d6-4fe0-93fc-19aad6a0b7ac.jpg?v=1767073433","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-6av7724-1bb10-0ad0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}