{"product_id":"siemens-6av7872-1ae52-1ab0-simatic-panel-pc-677b","title":"Siemens 6AV7872-1AE52-1AB0 SIMATIC Panel PC 677B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6AV7872-1AE52-1AB0\u003c\/strong\u003e is a \u003cstrong\u003eSIMATIC Panel PC 677B\u003c\/strong\u003e designed for industrial visualization and control applications. This panel PC features a 15-inch touch display with a resolution of 1024 x 768 pixels, and is powered by a Core 2 Duo T7400 processor running at 2.16 GHz. It includes 4 GB DDR2 RAM and a RAID1 configuration with two 250 GB SATA (2.5\") hard drives, along with a DVD+-R+-RW optical drive. Connectivity options include two 10\/100\/1000 Mbit\/s Ethernet ports, four USB V2.0 ports, and one serial (COM1) interface. It operates on a DC 24V power supply and supports PROFIBUS\/MP communication with 2 MB buffered SRAM. The unit comes pre-installed with Windows 2000 Professional MUI (Multi-User Interface) in multiple languages, and is supplied with hard drives only.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e15-inch Touch Display (1024 x 768 resolution)\u003c\/li\u003e\n    \u003cli\u003eCore 2 Duo T7400, 2.16 GHz CPU\u003c\/li\u003e\n    \u003cli\u003e4 GB DDR2 RAM\u003c\/li\u003e\n    \u003cli\u003eRAID1 with 2 x 250 GB SATA (2.5\") Hard Drives\u003c\/li\u003e\n    \u003cli\u003eIntegrated DVD+-R+-RW Optical Drive\u003c\/li\u003e\n    \u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet Ports\u003c\/li\u003e\n    \u003cli\u003eFour USB V2.0 Ports (without front side interface)\u003c\/li\u003e\n    \u003cli\u003eOne Serial (COM1) Port\u003c\/li\u003e\n    \u003cli\u003ePROFIBUS\/MP Interface with 2 MB Buffered SRAM\u003c\/li\u003e\n    \u003cli\u003eDC 24V Power Supply\u003c\/li\u003e\n    \u003cli\u003ePre-installed Windows 2000 Professional MUI (Multi-User Interface)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe SIMATIC Panel PC 677B is suitable for a wide range of industrial environments requiring robust and reliable computing solutions. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eIndustrial visualization and Human-Machine Interface (HMI) tasks\u003c\/li\u003e\n    \u003cli\u003eMachine control and monitoring systems\u003c\/li\u003e\n    \u003cli\u003eProcess automation and supervisory control\u003c\/li\u003e\n    \u003cli\u003eData acquisition and processing in manufacturing facilities\u003c\/li\u003e\n    \u003cli\u003eIntegration into Manufacturing Execution Systems (MES)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n                \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Panel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC677B\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC panels\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Ports\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 x USB V2.0 (without front side interface)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial Ports\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 x Serial (COM1)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15 inches\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Resolution\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024 x 768\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDC 24V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCPU\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCore 2 Duo T7400, 2.16 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSLC Cache\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4MB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExpansion Slots\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 x PCI\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 GB DDR2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStorage Configuration\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAID1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Drives\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 x 250 GB SATA (2.5\")\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Drive\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDVD+-R+-RW\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFieldbus Interface\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MP\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBuffered SRAM\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows 2000 Professional MUI (EN, GE, FR, IT, SP, JP, CHN, KOR)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHDD Configuration\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWith HDD only\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e67.00 x 83.00 x 11.50 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371098\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eInterface Type\u003c\/th\u003e\n                \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eQuantity \/ Specification\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 x USB V2.0\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 x COM1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFieldbus\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MP\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect the unit to a stable DC 24V power source, ensuring correct polarity and adequate current capacity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The Panel PC is designed for panel mounting. Ensure sufficient space for ventilation and cable routing behind the panel.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Properly ground the Panel PC chassis to the industrial ground system to minimize electromagnetic interference and ensure operational safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route power, signal, and communication cables separately to prevent interference. Use shielded cables for critical signals where appropriate.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Install the unit in an environment within its specified operating temperature and humidity ranges. Avoid direct sunlight, excessive vibration, and corrosive atmospheres.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePeripheral Connections:\u003c\/strong\u003e Connect Ethernet, USB, and serial devices as required. Ensure all connections are secure to prevent intermittent operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715862884715,"sku":"6AV7872-1AE52-1AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7872-1ae52-1ab0-dgzfdnqfnay_29902ecc-2889-479d-80b1-0f75fcce4594.jpg?v=1767073085","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-6av7872-1ae52-1ab0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}