{"product_id":"siemens-6av7892-0bh00-0ab0-simatic-ipc677c-panel-pc","title":"Siemens 6AV7892-0BH00-0AB0 SIMATIC IPC677C Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7892-0BH00-0AB0 is a SIMATIC HMI IPC677C series industrial panel PC engineered for process control and monitoring in demanding production environments. This unit integrates a \u003cstrong\u003e15-inch touchscreen display\u003c\/strong\u003e with a \u003cstrong\u003e1024 x 768 resolution\u003c\/strong\u003e into a rugged enclosure. It is powered by an \u003cstrong\u003eIntel Core i7-610E processor\u003c\/strong\u003e and equipped with extensive connectivity options, including dual Gigabit Ethernet, USB 2.0, and a PROFIBUS\/MPI interface. System reliability is enhanced by an onboard RAID controller, watchdog timer, and integrated monitoring for temperature and fan status. The device is pre-installed with Windows XP Professional and includes a 110\/230 V AC power supply.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 2em;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003e15-inch color touchscreen display with 1024 x 768 pixel resolution.\u003c\/li\u003e\n\u003cli\u003eIntel Core i7-610E processor (2.53 GHz, 2 Cores\/4 Threads, 4 MB Cache).\u003c\/li\u003e\n\u003cli\u003e1 GB DDR3 1066 DIMM system memory.\u003c\/li\u003e\n\u003cli\u003e250 GB SATA Hard Disk Drive (HDD) with onboard RAID controller.\u003c\/li\u003e\n\u003cli\u003eIntegrated PROFIBUS\/MPI interface (CP 5611-A2 compatible).\u003c\/li\u003e\n\u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet ports for network connectivity.\u003c\/li\u003e\n\u003cli\u003eFour rear USB 2.0 ports and one front-side USB port for easy access.\u003c\/li\u003e\n\u003cli\u003eBuilt-in system monitoring for watchdog, temperature, and fan operation.\u003c\/li\u003e\n\u003cli\u003eTwo free PCI slots for hardware expansion.\u003c\/li\u003e\n\u003cli\u003ePre-installed with Windows XP Professional SP3 (MUI).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 2em;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003eHuman-Machine Interface (HMI) for machine and process control.\u003c\/li\u003e\n\u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes.\u003c\/li\u003e\n\u003cli\u003eProduction data logging and visualization stations.\u003c\/li\u003e\n\u003cli\u003eIndustrial control rooms and operator panels.\u003c\/li\u003e\n\u003cli\u003eManufacturing Execution System (MES) terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 2em;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e15-inch Touchscreen, 1024 x 768 resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eIntel Core i7-610E (2C\/4T, 2.53 GHz, Turbo Boost, HT, VT, 4 MB Cache)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e1 GB DDR3 1066 DIMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eBuffered Memory\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e2 MB Buffered SRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e250 GB HDD SATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eRAID Controller\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOnboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOptical Drive\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e2x PCI (free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eUSB Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e4x USB 2.0 (rear), 1x Front-side USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSerial Port\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e1x COM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eFieldbus Interface\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePROFIBUS\/MPI (CP 5611-A2 compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e110\/230 V AC with NAMUR compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWindows XP Professional SP3 MUI (DE, EN, FR, ES, IT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSystem Monitoring\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWatchdog, Temperature Monitoring, Fan Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e17.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e67.00 x 55.00 x 28.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 2em;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px 20px; margin: 20px 0;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Ensure the main power supply to the cabinet is de-energized and locked out (LOTO) before beginning work. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003eVerify the panel cutout dimensions against the device specifications. Ensure adequate clearance for ventilation and cable routing behind the unit.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003eInsert the Panel PC into the prepared cutout from the front of the enclosure. Secure the unit evenly from the rear using all provided mounting clamps, tightening to the specified torque to ensure a proper seal.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003eConnect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the PC chassis. This is a mandatory safety connection.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003eConnect the 110\/230 V AC power supply cable to the device input. Ensure the source voltage matches the power supply rating.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003eConnect Ethernet, PROFIBUS\/MPI, USB, and any other required communication or peripheral cables. Ensure proper shielding and grounding for all data cables to minimize electrical noise interference.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e6\u003c\/span\u003e\n\u003cspan\u003eAfter verifying all connections are secure and correct, remove the lockout\/tagout device and re-energize the main cabinet power. Power on the Panel PC and confirm that the operating system boots correctly.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716347294059,"sku":"6AV7892-0BH00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7892-0bh00-0ab0-l42npfleblp_316e1d72-3613-42b9-8b4d-7712572d0284.jpg?v=1767080966","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-6av7892-0bh00-0ab0-simatic-ipc677c-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}