{"product_id":"siemens-6ds1717-8rr-teleperm-m-binary-calculation-module","title":"Siemens 6DS1717-8RR TELEPERM M Modul Pengiraan Binari","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6DS1717-8RR\u003c\/strong\u003e is a \u003cstrong\u003eBinary Calculation Module\u003c\/strong\u003e (often referred to as an arithmetic module) designed for the \u003cstrong\u003eTELEPERM M\u003c\/strong\u003e process control system. This module is engineered to handle logical and arithmetic processing of binary signals within the TELEPERM M automation architecture, which was traditionally used for large-scale process automation in power plants and industrial facilities. It plugs directly into the system's I\/O module subrack and interfaces with the process via the backplane and cabinet connection elements.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctionality:\u003c\/strong\u003e Performs binary logic operations and calculations necessary for process control sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for integration into TELEPERM M automation racks (such as those used in legacy AS 230\/AS 235 systems).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Built for industrial environments with specialized locking bars to secure the module in the subrack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComponent Handling:\u003c\/strong\u003e Contains electrostatically sensitive components; requires careful handling, commissioning, and maintenance procedures per standard Siemens ESD guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Used for logical signal processing and control in continuous or batch process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy System Maintenance:\u003c\/strong\u003e Serves as a critical spare part for existing TELEPERM M installations, which have been largely succeeded by modern systems like SPPA-T2000 (Teleperm XP) or SIMATIC PCS 7.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTELEPERM M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBinary Calculation Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (cm)\u003c\/td\u003e\n\u003ctd\u003e20.3 x 5.1 x 25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e As the module contains electrostatically sensitive devices, use proper ESD protection (grounding straps, anti-static mats) during installation and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the module into an available I\/O slot in the subrack and secure it firmly using the integrated locking bars.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e The process interface is established via the backplane connector (X2). Ensure the connection between the process interface and the field wiring is verified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Ensure the power is disconnected before installing or removing the module to avoid damage to the backplane or the module's circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716781437291,"sku":"6DS1717-8RR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6ds1717-8rr-onlgv0kccan_a0ee796c-3ff8-40d2-ba56-0deaeec63449.jpg?v=1767089555","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-6ds1717-8rr-teleperm-m-binary-calculation-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}