{"product_id":"siemens-6es7647-5eg10-2xx0-simatic-box-pc-620-industrial-pc","title":"Siemens 6ES7647-5EG10-2XX0 SIMATIC BOX PC 620 Industrial PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is the Siemens 6ES7647-5EG10-2XX0, a SIMATIC BOX PC 620 designed for robust industrial automation and control tasks. It is configured with a \u003cstrong\u003eCeleron 1.2 GHz\u003c\/strong\u003e processor, \u003cstrong\u003e128 MB SDRAM\u003c\/strong\u003e, and a \u003cstrong\u003e40 GB EIDE hard drive\u003c\/strong\u003e. Connectivity options include \u003cstrong\u003e10\/100 Mbit\/s Ethernet\u003c\/strong\u003e, \u003cstrong\u003ePROFIBUS\/MPI\u003c\/strong\u003e, and USB ports, providing flexible integration into existing control systems. The unit features onboard monitoring functions such as a watchdog timer and temperature monitoring and is powered by a \u003cstrong\u003e24 V DC\u003c\/strong\u003e industrial supply. This model is supplied without a pre-installed operating system, allowing for custom software configuration.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n    \u003cli\u003eProcessor: Celeron 1.2 GHz with 256 KB SLC\u003c\/li\u003e\n    \u003cli\u003eMemory: 128 MB SDRAM-133\u003c\/li\u003e\n    \u003cli\u003eStorage: 40 GB EIDE Hard Disk Drive\u003c\/li\u003e\n    \u003cli\u003eRemovable Media: 3.5-inch, 1.44 MB floppy drive\u003c\/li\u003e\n    \u003cli\u003eGraphics: Onboard AGP graphics, configurable for 8, 16, or 32 MB\u003c\/li\u003e\n    \u003cli\u003eExpansion: One free PCI slot and one free ISA\/PCI combination slot\u003c\/li\u003e\n    \u003cli\u003eConnectivity: 10\/100 Mbit\/s Ethernet, PROFIBUS\/MPI, TTY, and 2x USB ports\u003c\/li\u003e\n    \u003cli\u003eCard Reader: PC Card slot (PCMCIA Type 3)\u003c\/li\u003e\n    \u003cli\u003eSystem Monitoring: Integrated watchdog timer and temperature monitoring\u003c\/li\u003e\n    \u003cli\u003ePower Supply: Requires 24 V DC industrial power source\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n    \u003cli\u003eHuman-Machine Interface (HMI) visualization\u003c\/li\u003e\n    \u003cli\u003eData acquisition and logging\u003c\/li\u003e\n    \u003cli\u003ePC-based process control and automation\u003c\/li\u003e\n    \u003cli\u003eGateway and communication server roles\u003c\/li\u003e\n    \u003cli\u003eIndustrial computing in manufacturing and logistics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIndustrial PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCeleron 1.2 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProcessor Cache\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e256 KB SLC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e128 MB SDRAM-133\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e40 GB HDD EIDE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eRemovable Media\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e3.5\" Floppy Drive, 1.44 MB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGraphics\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOnboard AGP, configurable (8\/16\/32 MB)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e24 V DC, 85 A\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eEthernet Interface\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1x RJ45, 10\/100 Mbit\/s\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFieldbus Interface\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePROFIBUS\/MPI, 12 Mbit\/s\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAdditional Interfaces\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e2x USB, 1x TTY\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eExpansion Slots\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1x PCI (free), 1x ISA\/PCI (free)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCard Slot\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1x PC Card (PCMCIA Type 3)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eNot included\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e45.0 x 47.5 x 27.0 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e7.05 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages may be present. Installation must be performed by qualified personnel only. Ensure all power sources are de-energized and locked out\/tagged out (LOTO) before commencing any installation, wiring, or maintenance activities. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eMount Securely:\u003c\/strong\u003e Install the Box PC in a suitable industrial enclosure or control cabinet that provides protection from environmental factors. Ensure adequate ventilation space around the unit for heat dissipation.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect the chassis grounding terminal to the main protective earth (PE) busbar of the cabinet using a low-impedance conductor. A reliable ground connection is essential for safety and noise immunity.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect a stable, correctly rated 24 V DC power source to the designated power input terminals. Verify correct polarity before applying power. Use appropriate wire gauges for the connection.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eConnect Peripherals and Networks:\u003c\/strong\u003e Connect Ethernet, PROFIBUS\/MPI, USB, and any other required peripheral cables. Ensure all communication cables are properly shielded and routed away from high-voltage power lines to prevent interference.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eSystem Startup:\u003c\/strong\u003e Once all connections are secure, remove the LOTO device and apply power to the unit. Proceed with operating system installation and software configuration as required for the specific application.\u003c\/div\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716266783083,"sku":"6ES7647-5EG10-2XX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-5eg10-2xx0-zmpq302g4ec_4ab1ea62-45a5-4969-96dc-8948c2d74630.jpg?v=1767080142","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-6es7647-5eg10-2xx0-simatic-box-pc-620-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}