{"product_id":"siemens-6es7647-6af30-0bk0-simatic-box-pc-627-industrial-pc","title":"Siemens 6ES7647-6AF30-0BK0 SIMATIC BOX PC 627 Industrial PC","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis Siemens 6ES7647-6AF30-0BK0 is a SIMATIC BOX PC 627, a robust industrial computer designed for demanding automation environments. It is configured with a \u003cstrong\u003ePentium M 760 2.0 GHz processor\u003c\/strong\u003e, \u003cstrong\u003e1 GByte of DDR2 RAM\u003c\/strong\u003e, and an \u003cstrong\u003e80 GByte SATA hard drive\u003c\/strong\u003e. Connectivity options are extensive, including dual Ethernet ports, four high-current USB 2.0 ports, a serial port, and an integrated \u003cstrong\u003ePROFIBUS\/MPI interface\u003c\/strong\u003e for direct fieldbus communication. The unit features onboard monitoring for temperature and fan status, a watchdog timer for system reliability, and is powered by an AC 110\/230V industrial power supply.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003ePentium M 760 processor operating at 2.0 GHz\u003c\/li\u003e\n\u003cli\u003eOnboard AGP graphics with 8-128 MB shared memory\u003c\/li\u003e\n\u003cli\u003eIntegrated RAID controller for data redundancy\u003c\/li\u003e\n\u003cli\u003eDual 10\/100 Mbit\/s Ethernet ports for network connectivity\u003c\/li\u003e\n\u003cli\u003ePROFIBUS\/MPI interface for industrial communication\u003c\/li\u003e\n\u003cli\u003eFour high-current USB V2.0 ports\u003c\/li\u003e\n\u003cli\u003eBuilt-in watchdog timer and temperature\/fan monitoring\u003c\/li\u003e\n\u003cli\u003eTwo free PCI slots for hardware expansion\u003c\/li\u003e\n\u003cli\u003eSlot for a Compact Flash drive\u003c\/li\u003e\n\u003cli\u003ePre-installed with Windows XP Professional Multi-Language SP2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003eHuman-Machine Interface (HMI) server\u003c\/li\u003e\n\u003cli\u003eData acquisition and logging systems\u003c\/li\u003e\n\u003cli\u003eProcess visualization and control\u003c\/li\u003e\n\u003cli\u003eGateway between plant floor networks and enterprise systems\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and measurement tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC BOX PC 627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePentium M 760, 2.0 GHz, 533 MHz FSB, 2 MB SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1 GByte DDR2 533 SODIMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e80 GByte HDD SATA + DVD ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGraphics\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eAGP Graphics Onboard, 8-128 MB Shared Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 x 10\/100 Mbit\/s Ethernet RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eUSB Interface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e4 x USB V2.0 (High Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSerial Interface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1 x Serial (COM1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eFieldbus Interface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePROFIBUS\/MPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 x PCI (free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eRemovable Media\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1 x Slot for Compact Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eAC 110\/230V Industrial Power Unit with NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIncluded Power Cable\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEurope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWindows XP Professional Multi-Language SP2 (EN, GE, FR, IT, SP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSystem Monitoring\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWatchdog, Temperature\/Fan Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePLM Product Phase\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin (Estimate)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e7.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e92.0 x 21.0 x 14.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 16px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize the system and follow Lockout\/Tagout (LOTO) procedures before installation or maintenance can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, completely disconnect and lock out all AC power sources supplying the industrial PC and the control cabinet. Verify the absence of voltage with a properly rated meter.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eMount Securely:\u003c\/strong\u003e Install the Box PC on a stable, vibration-free surface within the control cabinet. Ensure all mounting screws are securely fastened to maintain mechanical stability and proper grounding continuity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eEnsure Ventilation:\u003c\/strong\u003e Maintain adequate clearance around the PC's ventilation openings as specified by the manufacturer to prevent overheating. Do not obstruct airflow with cables or other components.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Grounding:\u003c\/strong\u003e Connect the chassis to the main protective earth (PE) busbar of the cabinet using a low-impedance conductor. A reliable ground connection is essential for safety and noise immunity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect all required interface cables (Ethernet, USB, PROFIBUS, serial). Ensure cable shields for communication lines are properly terminated at one end to the cabinet ground to minimize electrical noise.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eApply Power:\u003c\/strong\u003e After verifying all connections are correct and secure, remove the lockout\/tagout devices and re-apply AC power to the system. Monitor the PC during its initial boot sequence.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716512641387,"sku":"6ES7647-6AF30-0BK0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-6af30-0bk0-l3oon0yd3ok_359c1bb3-2d8a-446b-a544-f104ca05b7c9.jpg?v=1767083744","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-6es7647-6af30-0bk0-simatic-box-pc-627-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}