{"product_id":"siemens-6gk1502-3cc10-simatic-net-optical-link-module","title":"Siemens 6GK1502-3CC10 SIMATIC NET Modul Pautan Optik","description":"\u003cp\u003eThe \u003cstrong\u003e6GK1502-3CC10\u003c\/strong\u003e is an industrial \u003cstrong\u003eOptical Link Module (OLM\/G12-1300 V3.1)\u003c\/strong\u003e designed to bridge RS485 electrical signals with fiber optic media in PROFIBUS networks. This \u003cstrong\u003ecommunication module\u003c\/strong\u003e facilitates long-distance data transmission by converting standard electrical signals into optical pulses, utilizing a 1300 nm wavelength for reliable performance over glass fiber optic cables. It features two integrated interfaces for fiber optic connections using four BFOC sockets, allowing for redundant or linear network topologies. The module includes an integrated signal contact for status monitoring and a dedicated measurement output for diagnostics, ensuring consistent network availability in complex industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e One RS485 interface for PROFIBUS connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Connectivity:\u003c\/strong\u003e Two interfaces for glass fiber optic cables (4 x BFOC sockets).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength:\u003c\/strong\u003e 1300 nm for extended transmission distances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Integrated signal contact and measurement output for network monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for use with SIMATIC NET and standard PROFIBUS systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLong-distance PROFIBUS data transmission.\u003c\/li\u003e\n\u003cli\u003eIndustrial networking in environments with high electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eBackbone connectivity for distributed I\/O and controller systems.\u003c\/li\u003e\n\u003cli\u003eFactory automation and process control installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eSimatic S5 \/ NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6GK1502-3CC10 (OLM\/G12-1300 V3.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Interface\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Optic Interface\u003c\/td\u003e\n\u003ctd\u003e2 (4 x BFOC sockets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWave Length\u003c\/td\u003e\n\u003ctd\u003e1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.20 x 5.10 x 15.20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9-pin Sub-D\u003c\/td\u003e\n\u003ctd\u003eRS485 PROFIBUS connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBFOC Socket (x4)\u003c\/td\u003e\n\u003ctd\u003eGlass Fiber Optic connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eSignal contact \/ Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e The module is designed for standard DIN rail mounting; ensure a secure mechanical lock before connecting cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain proper chassis grounding to minimize interference and ensure stable signal transmission on the RS485 link.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e When using glass fiber cables, adhere to the minimum bend radius specifications to prevent signal attenuation or fiber damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI\/RFI Mitigation:\u003c\/strong\u003e Keep fiber optic cables routed away from high-voltage power lines to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Utilize the signal contact output to trigger alarms on external PLC inputs in the event of a fiber link failure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716781338987,"sku":"6GK1502-3CC10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk1502-3cc10-aurq0ot2tvu_060e1d3d-4782-471a-828d-7cb6cede8c7d.jpg?v=1767089552","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-6gk1502-3cc10-simatic-net-optical-link-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}