{"product_id":"siemens-simatic-ipc827c-6es7647-6pj66-0lb0-industrial-box-pc","title":"Siemens SIMATIC IPC827C 6ES7647-6PJ66-0LB0 Industrial Box PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7647-6PJ66-0LB0 is a SIMATIC IPC827C series industrial box PC designed for demanding automation environments. This unit is equipped with an \u003cstrong\u003eIntel Core i7-610E processor\u003c\/strong\u003e, \u003cstrong\u003e4 GB of ECC DDR3 RAM\u003c\/strong\u003e, and a \u003cstrong\u003e240 GB SATA solid-state drive\u003c\/strong\u003e for robust performance and data integrity. It features an integrated PROFINET interface, making it suitable for real-time control and communication tasks. The system includes onboard monitoring for temperature and fans, a watchdog timer for high availability, and operates on a \u003cstrong\u003e24 V DC industrial power supply\u003c\/strong\u003e. This model comes pre-installed with Windows 7 Ultimate (32-bit).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eProcessor: Intel Core i7-610E (2.53 GHz, 2 Cores \/ 4 Threads)\u003c\/li\u003e\n  \u003cli\u003eMemory: 4 GB DDR3 1066 DIMM with ECC\u003c\/li\u003e\n  \u003cli\u003eStorage: 240 GB SATA Solid-State Drive (SSD)\u003c\/li\u003e\n  \u003cli\u003eOperating System: Windows 7 Ultimate 32-bit SP1 (MUI)\u003c\/li\u003e\n  \u003cli\u003eIndustrial Communications: Integrated PROFINET interface (CP 1616-compatible) with 3x RJ45 ports\u003c\/li\u003e\n  \u003cli\u003eStandard Ethernet: 2x 10\/100\/1000 Mbps RJ45 ports\u003c\/li\u003e\n  \u003cli\u003eExpansion Slots: 3x PCI, 1x PCIe (x4), 1x PCIe (x16)\u003c\/li\u003e\n  \u003cli\u003eOnboard Monitoring: Watchdog timer, temperature, and fan monitoring\u003c\/li\u003e\n  \u003cli\u003ePower Supply: 24 V DC input\u003c\/li\u003e\n  \u003cli\u003eAdditional Memory: 2 MB buffered SRAM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eProcess visualization and HMI stations\u003c\/li\u003e\n  \u003cli\u003eSCADA and data acquisition nodes\u003c\/li\u003e\n  \u003cli\u003eIndustrial data logging and analysis\u003c\/li\u003e\n  \u003cli\u003ePC-based machine control and automation\u003c\/li\u003e\n  \u003cli\u003eGateway and communication server applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n  \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n    \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eCategory\u003c\/th\u003e\n    \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eProcessor\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntel Core i7-610E (2 Cores, 4 Threads, 2.53 GHz, 4 MB Cache, Turbo Boost, HT, VT, AMT)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eMemory\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 GB DDR3 1066 DIMM, ECC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eBuffered Memory\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB Buffered SRAM\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eStorage\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e240 GB SATA Solid-State Drive (SSD)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eRemovable Media\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFront-accessible CompactFlash Drive Slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eGraphics\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOnboard HD Graphics\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eInterfaces\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbps Ethernet (RJ45)\u003cbr\u003e4x USB 2.0 (High Current)\u003cbr\u003e1x Serial (COM 1)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eIndustrial Network\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET Interface (CP 1616-compatible) with 3x RJ45 ports\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eExpansion Slots\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3x PCI\u003cbr\u003e1x PCIe (x4)\u003cbr\u003e1x PCIe (x16)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eStorage Controller\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOnboard RAID Controller\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003ePower Supply\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC Industrial Power Supply\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eOperating System\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows 7 Ultimate 32-bit SP1, Multi-language User Interface (EN, DE, FR, IT, ES)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eProduct Lifecycle\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGermany (Estimate)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003eShipping Weight\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e7.00 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #2d3748;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e119.5 x 14.0 x 5.0 cm\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n  \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: RISK OF ELECTRIC SHOCK\u003c\/p\u003e\n  \u003cp style=\"margin-bottom: 0;\"\u003eDisconnect all power sources before installation, servicing, or removal. Verify the absence of voltage using a properly rated test instrument. Failure to comply can result in severe injury or death.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eSite Preparation:\u003c\/strong\u003e Ensure the mounting location is free from excessive vibration, moisture, and extreme temperatures. Provide adequate clearance around the unit for ventilation and cable access.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely fasten the Box PC to a stable panel or surface using all provided mounting points. Verify the unit is level and firmly attached before proceeding.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis grounding terminal to the main system protective earth (PE) busbar using a low-impedance conductor. A reliable ground connection is essential for safety and noise immunity.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect a stable, properly-rated 24 V DC power source to the designated power input terminals. Ensure correct polarity. Use appropriately sized wiring and overcurrent protection as required by local codes.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eI\/O Cabling:\u003c\/strong\u003e Connect network, peripheral, and communication cables. Use shielded cables for all data lines, especially for PROFINET, and ensure shields are properly terminated to ground at one end to prevent ground loops. Route signal cables separately from high-voltage power lines.\u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716368888171,"sku":"6ES7647-6PJ66-0LB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-6pj66-0lb0-2yy50s3v355_4736323c-f8d8-4b2a-9edb-f70cf8398bda.jpg?v=1767081444","url":"https:\/\/www.plcprotech.com\/ms\/products\/siemens-simatic-ipc827c-6es7647-6pj66-0lb0-industrial-box-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}