{"title":"Bently Nevada 3500 System Machinery Protection","description":"\u003cp\u003eThe Bently Nevada 3500 System is a premier rack-based machinery protection platform designed to provide continuous, automatic oversight of critical rotating assets. Its architecture consists of a centralized rack housing power supplies, Transient Data Interfaces (TDI), and various monitor modules tailored for vibration, position, and speed. Key technical characteristics include high-density channel configurations, redundant power options, and extensive backplane digital communications. This system is functionally capable of providing SIL-certified protection, delivering both local alarm relay logic and seamless data integration into System 1 software. It serves as the primary defense mechanism for turbines and compressors, often interfacing with the \u003cstrong\u003e\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-xl-proximitor-sensor\"\u003e3300 XL Proximitor Sensor\u003c\/a\u003e \u003c\/strong\u003eto ensure machinery trips occur instantly when safety thresholds are breached, preventing extensive mechanical damage.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-3500-40m-140734-01-proximitor-monitor","title":"Monitor Proximitor Bently Nevada 3500\/40M 140734-01","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eBently Nevada 3500\/40M (Numer części: 140734-01) to wysokowydajny, czterokanałowy moduł monitorujący ochronę maszyn, zaprojektowany dla systemu ochrony maszyn serii 3500. Urządzenie przyjmuje ciągłe sygnały analogowe z różnych przetworników zbliżeniowych Bently Nevada, przetwarzając je w celu śledzenia krytycznych parametrów wału, w tym drgań promieniowych, ekscentryczności, pozycji osiowej, REBAM i rozszerzenia różnicowego.\u003c\/p\u003e\n\u003cp\u003ePrzetwarzane parametry są ciągle porównywane z programowalnymi przez użytkownika progami alarmowymi, aby wykonywać automatyczne awaryjne wyłączenia maszyn. Konfiguracja 140734-01 reprezentuje główny układ wewnętrznego zakończenia sprzętowego, który łączy płytę tylnego panelu systemu bezpośrednio z czujnikami terenowymi. Ten moduł dostarcza dane ochrony maszyn operatorom zakładu, jednocześnie wysyłając zmienne diagnostyczne do sieci zarządzania zasobami.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumer części głównej płyty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140734-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuł monitorujący Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKompatybilność systemu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem ochrony maszyn serii 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePojemność kanałów\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 niezależne kanały na moduł\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCel wejścia sygnału\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePrzetworniki zbliżeniowe prądów wirowych\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUkład zakończenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterfejs wewnętrznego zakończenia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramowalne funkcje\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWibracje promieniowe, pozycja osiowa, ekscentryczność, REBAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eParametry punktów alarmowych\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 poziomy alarmowe, 2 poziomy niebezpieczeństwa na aktywny kanał\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrędkość przetwarzania sygnału\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCiągłe próbkowanie analogowe w czasie rzeczywistym\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWskaźniki stanu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDioda LED OK, TX\/RX i Bypass na panelu przednim\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary (SxWxG)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,6 cm x 25,8 cm x 24,0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga netto produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,80 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStany Zjednoczone (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cp\u003eKonserwacja przemysłowych maszyn wirnikowych wymaga śledzenia dokładnych numerów części modułów, aby zapewnić kompatybilność z istniejącymi płytami tylnego panelu i konfiguracjami monitoringu.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOznaczenie typu modułu:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/40M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIdentyfikator głównego zespołu drukowanego (PWA):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e140734-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePodtyp komponentu I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModuł I\/O Proximitor z wewnętrznym zakończeniem\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik konfiguracji sprzętu i inżynierii\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eZasady konfiguracji par kanałów\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3500\/40M przetwarza sygnały z czujników zbliżeniowych za pomocą sparowanych ścieżek kanałów (Kanały 1 i 2 oraz Kanały 3 i 4). Przy przypisywaniu trybów funkcjonalnych za pomocą oprogramowania 3500 Rack Configuration Software, zaprogramowane wybory muszą być zgodne z wytycznymi dotyczącymi konfiguracji par. Na przykład, można jednocześnie wykonywać do dwóch różnych funkcji monitorowania na jednej parze, pod warunkiem, że podstawowe częstotliwości próbkowania przetworników są zgodne. Nieodpowiednie typy czujników na wspólnej parze kanałów spowodują błędy walidacji oprogramowania podczas przesyłania konfiguracji.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWewnętrzne zakończenia okablowania polowego\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePonieważ 140734-01 posiada wewnętrzne zakończenia, kable przedłużające czujniki polowe podłącza się bezpośrednio do zacisków śrubowych z tyłu modułu.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrzygotowanie:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsuń izolację poszczególnych przewodów na dokładnie 7 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOkablowanie:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUżywaj skręconego, ekranowanego kabla trzyżyłowego dla każdego połączenia sondy (\u003cstrong\u003eZasilanie, Sygnał, Komunikacja\u003c\/strong\u003e), aby odizolować system od zakłóceń elektromagnetycznych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUziemienie:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz zewnętrzne ekrany kabli do dedykowanej szyny uziemiającej instrumentacji wewnątrz obudowy szafy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProcedura wymiany na gorąco\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł 3500\/40M obsługuje wymianę na gorąco, gdy główna szafa jest zasilana. Jednak usunięcie aktywnego modułu monitora natychmiast powoduje zadziałanie przekaźnika \"OK\" i wprowadza zależne kanały w stan nieprawidłowy.\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eZmień fizyczny przełącznik blokady klucza szafy z\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"RUN\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ena\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etryb.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWłącz flagi\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eomijania kanału\u003c\/strong\u003e w oprogramowaniu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWyjmij uszkodzoną płytę 140734-01, aby uniknąć wywołania fałszywego awaryjnego wyłączenia maszyny.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ dotyczące konserwacji i rozwiązywania problemów\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jaka jest funkcjonalna różnica między monitorami 3500\/40M a starszymi 3500\/40?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Oznaczenie \"M\" wskazuje na rozszerzone możliwości przetwarzania. Model 3500\/40M posiada szybsze wewnętrzne pętle przetwarzania sygnału, rozszerzone rejestry pamięci do rejestracji danych przejściowych oraz bardziej efektywne przesyłanie ciągłych wartości statycznych do nowoczesnych sieci sterowania.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Z którymi przetwornikami polowymi można zintegrować moduł 140734-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Ten moduł jest zoptymalizowany dla systemów przetworników Bently Nevada Proximitor o średnicach 8 mm, 11 mm i 25 mm. Obsługuje standardowe długości pętli 5 i 9 metrów, przekształcając surowe wartości napięcia szczeliny na skalibrowane odczyty drgań lub położenia.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jak diody LED na panelu przednim pomagają w diagnostyce i rozwiązywaniu problemów?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStały zielony \"OK\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNormalna praca.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMigający czerwony \"OK\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWewnętrzna usterka sprzętowa lub niezgodność konfiguracji.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMigający bursztynowy \"TX\/RX\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAktywna komunikacja przez wewnętrzne linie magistrali danych szafy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515161451,"sku":"3500\/40M 140734-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-40m-140734-01-proximitor-monitor-fzuhngamh0b_6277bb18-daed-4044-bae8-f490e4d427b0.jpg?v=1765440072"},{"product_id":"bently-nevada-163179-02-3500-61-temperature-monitor","title":"Bently Nevada 163179-02 3500\/61 Monitor temperatury","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e163179-02\u003c\/strong\u003e\u003c\/span\u003e to profesjonalny, 6-kanałowy przyrząd do monitorowania temperatury, zaprojektowany dla standardowego w branży systemu ochrony maszyn \u003cspan\u003e\u003cstrong\u003eBently Nevada 3500 Series\u003c\/strong\u003e\u003c\/span\u003e. Działając jako podstawowy moduł oceny termicznej, karta ta nieustannie przetwarza sygnały z czujników rezystancyjnych (RTD) oraz termopar, chroniąc kluczowe elementy maszyn przed przeciążeniem termicznym. W środowiskach przemysłowych o dużym obciążeniu — w tym w elektrowniach cieplnych, kompleksach skraplania LNG oraz rafineriach petrochemicznych o dużej wydajności — \u003cspan\u003e\u003cstrong\u003e163179-02\u003c\/strong\u003e\u003c\/span\u003e służy do monitorowania krytycznych temperatur łożysk, uzwojeń stojana oraz przewodów płynów smarnych. Zapewniając identyczną funkcjonalność operacyjną jak podstawowa infrastruktura 3500\/61 wraz z sześcioma zintegrowanymi kanałami analogowymi rejestratorów, moduł umożliwia niezależne rejestrowanie telemetrii. Ciągły nadzór pozwala systemowi bezpieczeństwa na szybkie uruchomienie automatycznych poleceń wyłączenia, zanim krytyczne tarcie lub utrata chłodzenia spowodują katastrofalne uszkodzenia komponentów, znacznie redukując nieplanowane przestoje zakładu.\u003c\/p\u003e\n\u003ch3\u003eArchitektura sprzętowa i kierowanie telemetrią\u003c\/h3\u003e\n\u003cp\u003eFunkcjonalna konstrukcja, izolacja sprzętowa oraz analogowe pętle śledzące w \u003cspan\u003e\u003cstrong\u003e163179-02\u003c\/strong\u003e\u003c\/span\u003e zapewniają bardzo elastyczne i bezpieczne monitorowanie termiczne maszyn:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRównoległe pozyskiwanie sygnałów z sześciu kanałów:\u003c\/strong\u003e Ocena sześciu niezależnych analogowych wejść temperatury jednocześnie, zapewniając dedykowane, szybkie kondycjonowanie sygnału na wszystkich kanałach bez opóźnień skanowania.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWbudowane źródła prądowe pętli:\u003c\/strong\u003e Posiada sześć zintegrowanych wyjść prądowych +4 do +20 mA proporcjonalnych do pełnej skali konfiguracji monitora, umożliwiając bezproblemowe kierowanie analogowej telemetrii do zewnętrznych systemów DCS lub SCADA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOchrona przed zwarciami w pętli:\u003c\/strong\u003e Zawiera niezależną elektroniczną izolację uszkodzeń na wszystkich obwodach wyjściowych rejestratora, zapewniając, że zwarcia lub przerwy w okablowaniu zewnętrznym nie wpływają na podstawową logikę ochrony maszyn.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKompatybilność z adaptacyjną architekturą I\/O:\u003c\/strong\u003e Działa niezawodnie z wewnętrznymi i zewnętrznymi modułami zakończeniowymi oraz specjalistycznymi wewnętrznymi barierami bezpieczeństwa, dostosowując się do różnych standardów strefowych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCiągła rutyna autodiagnostyczna:\u003c\/strong\u003e Wykorzystuje wewnętrzny układ watch-dog monitorujący integralność okablowania wejściowego i transferów danych na magistrali, sygnalizując błędy na panelu czołowym w przypadku przerwania lub zwarcia pętli czujnika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eParametry techniczne i progi operacyjne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja sprzętowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertyfikowana wartość inżynieryjna\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIdentyfikacja modelu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e163179-02 (3500\/61)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProducent marki\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinia systemu sterowania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKlasyfikacja modułu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-kanałowy monitor temperatury z rejestratorami\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZakres wyjścia analogowego\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kanałów dedykowanych pętli prądowych +4 do +20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominalne zużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eŚrednie zużycie 9,0 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy (standardowe I\/O)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZakres termiczny otoczenia od -30 do +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy (wewnętrzna bariera)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZakres termiczny otoczenia od 0 do +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGranice strukturalne od -40 do +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga netto sprzętu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary fizyczne\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm W x 24,4 mm S x 241,8 mm G\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMiejsce produkcji\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinden, Nevada, USA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania dotyczące bezpieczeństwa maszyn i monitorowania termicznego\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCzy uszkodzenie okablowania pętli zewnętrznej na wyjściach rejestratora przerywa główną logikę wyłączenia maszyny?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie. Platforma sprzętowa 163179-02 posiada pełną galwaniczną i elektroniczną izolację zwarciową na każdym indywidualnym wyjściu prądowym +4 do +20 mA rejestratora. W przypadku zwarcia lub usterki uziemienia w pętli instrumentu polowego, podstawowy monitoring ochrony i automatyczne sygnały przekaźnikowe pozostają w pełni funkcjonalne.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo powoduje różnice w dolnym limicie temperatury pracy w różnych instalacjach?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGranice termiczne zmieniają się w zależności od wybranego modułu interfejsu magistrali. Użycie standardowych wewnętrznych lub zewnętrznych modułów zakończeniowych I\/O pozwala na pracę w szerokim zakresie od -30 do +65 °C. Natomiast w połączeniu z wewnętrznymi modułami barier bezpieczeństwa dla ochrony przeciwwybuchowej dolna granica operacyjna przesuwa się do zakresu 0 do +65 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy wartości rejestratora są regulowane, czy mają stałą skalę względem zakresu wejściowego?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSześć niezależnych wyjść prądowych generuje sygnały analogowe ściśle proporcjonalne do pełnej skali ustawionej w module monitora 3500\/61. Te wartości są płynnie mapowane na zaprogramowane przez użytkownika punkty alarmowe i niebezpieczne, ustalane za pomocą oprogramowania konfiguracyjnego 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstrukcja inżynieryjna i montażowa\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegralność ekranu i dopasowanie przewodów czujników:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrzeprowadź wszystkie kable polowe RTD i termopar przez wysokiej jakości skręcane pary przewodów ekranowanych, aby zapobiec indukcji zakłóceń elektromagnetycznych zasilania silników wysokiego napięcia. Ekran miedziany oplotu zakończ wyłącznie na wyznaczonej szynie uziemiającej w obudowie karty 3500. Upewnij się, że przewody polowe mają dopasowaną długość i przekrój, szczególnie w układach RTD 3-przewodowych, aby wyeliminować nierównowagę rezystancji linii powodującą dryf pomiaru na zaciskach wejściowych 3500\/61.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrzepisy dotyczące barier bezpieczeństwa przeciwwybuchowego i wentylacji termicznej:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePodczas instalacji modułu 163179-02 w systemach z wewnętrznymi barierami bezpieczeństwa przeciwwybuchowego, zapewnij, że temperatura otoczenia nie spada poniżej 0 °C. Zachowaj wolne przestrzenie pionowe nad i pod szafą 3500, aby umożliwić swobodny przepływ powietrza przez panel karty. Sprawdź, czy sąsiednie sloty spełniają standardowe zasady obciążenia mocy, aby utrzymać rozpraszanie ciepła znacznie poniżej maksymalnej wartości, zapobiegając przyspieszonemu starzeniu się komponentów.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWkładanie karty do obudowy i moment dokręcania mocowań mechanicznych:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrzed wsunięciem głównej płytki do aktywnego slotu, wizualnie sprawdź rzędy złączy magistrali pod kątem zanieczyszczeń lub wygiętych pinów. Wprowadź płytkę równomiernie wzdłuż górnych i dolnych prowadnic obudowy, aż tylne piny pewnie połączą się z gniazdem magistrali. Ręcznie dokręć górne i dolne śruby mocujące, aby zapewnić solidne uziemienie konstrukcyjne, a wszystkie połączenia zacisków polowych dokręć zgodnie z fabrycznymi specyfikacjami, aby zapobiec zmianom sygnału wywołanym drganiami.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515226987,"sku":"3500\/61 163179-02","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-163179-02-temperature-monitor-xhteguywf4j_0b27118e-8724-42a3-9c4b-2bfdc2837e3f.jpg?v=1765440073"},{"product_id":"bently-nevada-176449-04-3500-45-position-monitor-1","title":"Bently Nevada 176449-04 3500\/45 Monitor Pozycji","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eModel\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto wysokiej integralności, 4-kanałowa karta pomiarowa opracowana dla przemysłowego standardu\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500 Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystemu Ochrony Maszyn. Działając jako specjalistyczny monitor pozycji, ta karta przetwarza dynamiczne sygnały wejściowe z sond zbliżeniowych, obrotowych przetworników położenia (RPT), potencjometrów obrotowych oraz zarówno prądowych, jak i napięciowych liniowych przetworników różnicowych (LVDT). Krytyczne środowiska procesów ciągłych — takie jak elektrownie cieplne o stałym obciążeniu, rafinerie petrochemiczne i ciężkie operacje wydobywcze — polegają na modelu\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edo śledzenia makromechanicznych ruchów kluczowych turbin maszynowych. Monitorując parametry takie jak pozycja osiowego nacisku, różnicowa ekspansja, ekspansja obudowy i pozycje zaworów, dostarcza wczesne ostrzeżenia o odchyleniach strukturalnych. Ten ciągły nadzór inicjuje automatyczne polecenia wyłączenia podczas niebezpiecznych zmian mechanicznych, chroniąc ciężkie wirujące zasoby i znacznie skracając nieplanowane przestoje.\u003c\/p\u003e\n\u003ch3\u003eArchitektura mechaniczna i ocena sygnału\u003c\/h3\u003e\n\u003cp\u003eInfrastruktura sprzętowa, ramy kompatybilności wieloprzetwornikowej oraz logika algorytmów\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eobsługuje elastyczne konfiguracje diagnostyki maszyn:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrzydział kanałów w parach:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eZarządza danymi na czterech niezależnych kanałach zaprogramowanych w parach, pozwalając modułowi na jednoczesne wykonywanie do dwóch odrębnych funkcji pozycjonowania (np. kanały 1 i 2 przetwarzają pozycję osiową, podczas gdy kanały 3 i 4 monitorują pozycję zaworu).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWszechstronne interfejsowanie przetworników:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePosiada wbudowane, programowalne przez oprogramowanie sieci kondycjonowania wejścia, które płynnie dostosowują wewnętrzną impedancję wejściową i profile wzbudzenia do różnych technologii czujników.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitorowanie progów dwupoziomowych:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUstawia indywidualne, konfigurowalne progi alarmowe dla wszystkich aktywnych mierzonych zmiennych, wraz z dostosowywanymi poziomami niebezpieczeństwa przypisanymi do dowolnych dwóch wyznaczonych krytycznych zmiennych na parę kanałów.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNiezależne nagrywanie telemetrii:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDostarcza indywidualne izolowane analogowe wyjścia rejestratora +4 do +20 mA dla oddzielnych kanałów, umożliwiając niezawodne śledzenie przez zewnętrzne sieci DCS i SCADA bez zakłócania głównych pętli ochronnych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostyka błędów wysokiej prędkości:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWykonuje wewnętrzne skany diagnostyczne z prędkością aktualizacji 100 ms lub mniej, weryfikując prawidłowość ścieżki sygnału analogowego i zmieniając lokalne stany diod LED w przypadku awarii przetwornika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWskaźniki fizyczne i wydajnościowe\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr sprzętowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertyfikowana wartość przemysłowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIdentyfikacja modelu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e176449-04 (3500\/45)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProducent marki\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinia systemu sterowania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem ochrony maszyn 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKlasyfikacja modułu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-kanałowy monitor ciągłej pozycji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOpcje przetworników\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity, RPT, potencjometr obrotowy, AC\/DC LVDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaksymalna liczba kanałów\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 wejścia sygnałowe na kartę\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalogowe wyjście prądowe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePętle rejestratora prądu analogowego +4 do +20 mA (obciążenie 0 do 600 Ohm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRozdzielczość pętli\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,3662 uA na bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCzęstotliwość odświeżania telemetrii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 ms lub mniej\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5,6 do 8,5 W typowo (zależne od przetwornika)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 do +65 st. C Zakres temperatur otoczenia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga fizyczna\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,91 kg Waga netto podstawy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary zewnętrzne\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm W x 24,4 mm S x 241,8 mm G\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMiejsce produkcji\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinden, Nevada, USA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania dotyczące ochrony maszyn i konfiguracji\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJak operatorzy przypisują różne funkcje mechaniczne do czterech kanałów wejściowych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKanały monitora są programowane parami za pomocą oprogramowania 3500 Rack Configuration Software. Kanały 1 i 2 mogą realizować jedną konkretną funkcję — na przykład standardowe różnicowe rozszerzenie z pojedynczym nachyleniem — podczas gdy kanały 3 i 4 mogą działać według identycznego profilu lub całkowicie innego układu, takiego jak pozycja zaworu lub rozszerzenie obudowy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie zmiany w zasilaniu zachodzą wewnątrz monitora podczas przełączania między typami przetworników?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWewnętrzne zużycie energii zmienia się w zależności od wybranej podkarty interfejsu I\/O. Typowo pobiera 7,7 W przy standardowym pozycjonowaniu I\/O, wzrasta do 8,5 W typowo przy obciążeniach AC LVDT I\/O, a spada do 5,6 W typowo podczas odczytu układów niskoprądowych potencjometrów obrotowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak moduł 176449-04 reaguje na zewnętrzne zwarcia na swoich pętlach rejestratora?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł integruje pełną elektroniczną izolację zwarciową na wszystkich indywidualnych liniach wyjściowych rejestratora +4 do +20 mA. W przypadku zewnętrznego zwarcia lub błędu okablowania na dalszym odcinku pętli rejestracyjnej, podstawowa logika ochrony maszyn i zadania wykrywania alarmów działają bez przerwy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik inżynieryjny i instalacyjny\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStrojenie wzbudzenia przetwornika i optymalizacja napięcia szczeliny:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrzed zamocowaniem monitora 176449-04 w szafie 3500, sprawdź, czy dopasowany moduł I\/O backplane odpowiada typowi fizycznego czujnika w terenie. Dla sond zbliżeniowych zweryfikuj, czy zasilanie czujnika dostarcza stabilne napięcie wzbudzenia -24 VDC, natomiast dla połączeń AC LVDT wymagany jest dokładny nośnik sinusoidalny 2,3 Vrms o częstotliwości 3400 Hz. W konfiguracjach osiowego nacisku i różnicowej ekspansji ustaw końcówkę sondy tak, aby odczytywała dokładne napięcie punktu środkowego mechanicznego, zgodnie z fabrycznie określonymi marginesami napięcia szczeliny DC, aby zmaksymalizować liniowy zakres pomiarowy czujnika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMetody uziemienia ekranu i redukcja zakłóceń:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrzeprowadź wszystkie przewody czujników przez indywidualne ekranowane przewody skrętkowe, utrzymując linie sygnału pozycji z dala od przewodów zasilających o wysokiej mocy lub kabli sterowania silnikiem VFD. Zakończ zewnętrzną miedzianą siatkę ekranu wyłącznie na wyznaczonych listwach uziemiających systemu wewnątrz szafy rack instrumentu 3500. Pozostaw ekran pływający i dobrze izolowany przy skrzynce zakończeniowej czujnika w terenie, aby zapobiec prądom pętli uziemienia, które mogłyby wprowadzać zakłócenia elektryczne do wysokoomowych wejść DC LVDT o impedancji 1 M Ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZarządzanie termiczne i wyrównanie obudowy kart:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePłyta główna 176449-04 działa w przemysłowym zakresie temperatur otoczenia od -30 do +65°C. Podczas instalacji wysokiej gęstości w szafach rack, sprawdź, czy wentylatory szafy zapewniają czysty, stały pionowy przepływ powietrza przez prowadnice slotów. Wkładając moduł monitora do obudowy rack, przesuwaj podłoże równomiernie wzdłuż prowadnic kart, aby uniknąć wygięcia pinów złącza backplane, a następnie ręcznie dokręć górne i dolne śruby motylkowe, aby zapewnić niskooporowe uziemienie konstrukcyjne.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515325291,"sku":"3500\/45 176449-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-45-176449-04-position-monitor-4rrb2jhbz2i_0279879a-8618-4b86-948e-05407010c3b3.jpg?v=1765440075"},{"product_id":"bently-nevada-3500-60-133811-01-temperature-monitor","title":"Monitor temperatury Bently Nevada 3500\/60 133811-01","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/60 (133811-01 zastąpiony przez PN \u003ca href=\"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-60-163179-01-temperature-monitor-without-recorders\" title=\"Bently Nevada 3500\/60 163179-01 Temperature Monitor Without Recorders\"\u003e163179-01\u003c\/a\u003e)\u003c\/strong\u003e to wysokoprecyzyjny moduł monitorowania temperatury z 6 kanałami, zaprojektowany dla systemu ochrony maszyn Bently Nevada 3500. Moduł ten zapewnia kluczowy nadzór termiczny nad zasobami przemysłowymi w elektrowniach, zakładach naftowych i gazowych oraz w przemyśle chemicznym, takich jak łożyska silników, obudowy turbin i uzwojenia sprężarek. Przyjmując bezpośrednie sygnały zarówno z czujników rezystancyjnych (RTD), jak i termopar (TC), \u003cstrong\u003e3500\/60\u003c\/strong\u003e przetwarza te sygnały i porównuje je z ustawionymi przez użytkownika progami alarmowymi. Jego zdolność do natychmiastowego generowania alertów i wyłączeń awaryjnych jest niezbędna do zapobiegania katastrofalnym awariom mechanicznym spowodowanym przegrzaniem, co znacząco zmniejsza nieplanowane przestoje i wydłuża żywotność kluczowych maszyn obrotowych.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003eArchitektura \u003cstrong\u003e3500\/60\u003c\/strong\u003e została zaprojektowana z myślą o maksymalnej elastyczności i przemysłowej jakości sygnału dla różnych typów przetworników.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWszechstronna kompatybilność wejść:\u003c\/strong\u003e Obsługuje termopary typu E, J, K i T oraz czujniki RTD: miedziane 10 Ohm, niklowe 120 Ohm i platynowe 100 Ohm (alfa 0,00385 i 0,00392) w konfiguracjach 3- lub 4-przewodowych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpcje izolacji:\u003c\/strong\u003e Dostępny z izolowanymi modułami I\/O dla termopar, zapewniającymi izolację kanałową na poziomie 250 VDC, chroniąc system przed zewnętrznymi zakłóceniami elektromagnetycznymi i pętlami masy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancja i głosowanie:\u003c\/strong\u003e W pełni kompatybilny z konfiguracjami racków Triple Modular Redundant (TMR). W trybie TMR system wykorzystuje specjalną logikę głosowania pomiędzy trzema sąsiednimi modułami, aby zapewnić ciągłość ochrony nawet w przypadku awarii pojedynczego elementu sprzętowego.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDefiniowany programowo:\u003c\/strong\u003e Wszystkie parametry kanałów, w tym typ przetwornika i zakres pomiarowy, konfigurowane są za pomocą oprogramowania 3500 Rack Configuration Software, co eliminuje konieczność ręcznej kalibracji sprzętowej.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/60 (133811-01)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKanały wejściowe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kanałów (RTD lub TC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePobór mocy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 W nominalnie\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWiększa niż 10 MOhm na przewód\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRozdzielczość\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 °C lub 1 °F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDokładność (RTD\/TC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±3 °C przy 25 °C (standardowy wewnętrzny terminator)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C do +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C do +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,91 kg (2,0 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest podstawowa różnica między 3500\/60 a 3500\/61?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOba moduły oferują identyczną funkcjonalność monitorowania 6 kanałów; jednak 3500\/61 posiada dedykowane wyjścia rejestratora +4 do +20 mA dla każdego kanału, podczas gdy 3500\/60 nie oferuje tych wyjść analogowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy można mieszać wejścia RTD i TC w tym samym module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak. W wersji I\/O RTD\/TC bez izolacji użytkownik może niezależnie konfigurować każdy kanał do przyjmowania sygnału z termopary lub czujnika RTD, co pozwala na hybrydową konfigurację wejść w jednym slocie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo się stanie, jeśli przewód czujnika się zerwie lub dojdzie do zwarcia?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł nieustannie monitoruje stan przetwornika. W przypadku wykrycia usterki (np. przerwy w przewodzie RTD) dioda \"OK\" zgaśnie, a kanał przejdzie w stan \"Nie OK\", zapobiegając fałszywym wyłączeniom i jednocześnie informując operatorów o konieczności konserwacji.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWytyczne inżynieryjne dotyczące instalacji i bezpieczeństwa\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecyzja okablowania RTD:\u003c\/strong\u003e W instalacjach RTD 3-przewodowych należy zapewnić, aby wszystkie trzy przewody miały tę samą rezystancję. Różnice w rezystancji przewodów wprowadzą błędy pomiarowe, których moduł nie jest w stanie automatycznie skompensować. Dla najwyższej dokładności na długich odcinkach zaleca się konfiguracje RTD 4-przewodowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKompensacja złącza zimnego (CJC):\u003c\/strong\u003e Przy użyciu termopar dokładność zależy od czujnika CJC umieszczonego na module I\/O. Należy upewnić się, że moduł I\/O jest stabilnie zamontowany i nie jest narażony na bezpośrednie przeciągi ani lokalne źródła ciepła w szafie, które mogłyby powodować gradient temperatury na listwie zaciskowej.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUwagi dotyczące stref zagrożonych wybuchem:\u003c\/strong\u003e Jeśli czujniki temperatury znajdują się w strefie zagrożonej wybuchem, moduł musi być używany z zatwierdzonymi zewnętrznymi barierami Zenera. Należy pamiętać, że stosowanie barier zewnętrznych przesuwa dolny limit \"OK\" modułu do -50 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUziemienie obudowy:\u003c\/strong\u003e Aby zachować określoną dokładność i odporność na zakłócenia elektromagnetyczne, rack 3500 musi być prawidłowo uziemiony. Ekrany kabli sygnałowych powinny być podłączone do wyznaczonych zacisków uziemiających na module I\/O, aby zapobiec zakłóceniom w sygnałach o wysokiej impedancji i niskim napięciu z termopar i RTD.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515652971,"sku":"3500\/60 133811-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-60-133811-01-temperature-monitor-m3jlh05ejck_48ec3de4-6c40-4fc1-a26b-38e0bc7d3296.jpg?v=1765440081"},{"product_id":"bently-nevada-176449-09-3500-70m-recip-impulse-velocity-monitor","title":"Bently Nevada 176449-09 3500\/70M Monitor prędkości impulsów tłokowych","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e176449-09 (3500\/70M)\u003c\/strong\u003e\u003c\/span\u003e to specjalistyczny moduł monitorujący 4-kanałowy, zaprojektowany specjalnie dla pakietu rozwiązań sprężarek tłokowych w systemie ochrony maszyn Bently Nevada 3500. Przeznaczony do pracy w wymagających środowiskach przesyłu gazu, rafinerii hydroodsiarczania i przetwórstwa chemicznego, moduł ten przyjmuje sygnały z przetworników sejsmicznych, aby monitorować krytyczne poziomy drgań w skrzyni korbowej i głowicy tłoka. Wykorzystując zaawansowane algorytmy przyspieszenia impulsowego i prędkości tłokowej, \u003cspan\u003e\u003cstrong\u003e176449-09\u003c\/strong\u003e\u003c\/span\u003e wykrywa luzy mechaniczne i zdarzenia uderzeniowe na długo przed ich eskalacją do katastrofalnych uszkodzeń ramy lub pręta. Jego integracja z szafą 3500 zapewnia ciągłą ochronę maszyn, dostarczając niezbędne dane diagnostyczne, które pozwalają operatorom przejść od reaktywnych napraw do zoptymalizowanych, opartych na stanie harmonogramów konserwacji.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003eModuł 3500\/70M wykorzystuje wszechstronną architekturę 4-kanałową, zaprojektowaną dla unikalnych dynamicznych sygnatur maszyn tłokowych.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgramowanie podwójnych par:\u003c\/strong\u003e Kanały są programowane parami (1\/2 i 3\/4), co pozwala monitorowi wykonywać dwie różne funkcje jednocześnie na czterech wejściach. Obsługiwane funkcje to Przyspieszenie impulsowe, Przyspieszenie 2, Prędkość tłokowa oraz Niskoczęstotliwościowa prędkość tłokowa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eObróbka sygnału:\u003c\/strong\u003e Moduł przetwarza surowe sygnały sejsmiczne, aby wyznaczyć szczytowe wartości drgań, które następnie porównywane są z programowalnymi przez użytkownika progami alarmowymi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuforowane wyjścia:\u003c\/strong\u003e Panel przedni wyposażony jest w cztery zabezpieczone przed zwarciem złącza koncentryczne (po jednym na kanał), umożliwiające bezpośredni dostęp do surowych sygnałów z przetworników dla zewnętrznych urządzeń diagnostycznych bez naruszania pętli ochronnej.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogika alarmów Ostrzeżenie\/Zagrożenie:\u003c\/strong\u003e Każdy kanał może być skonfigurowany z niezależnymi progami Ostrzeżenie i Zagrożenie, które sterują przekaźnikami systemowymi, wyzwalając automatyczne wyłączenia maszyn lub ostrzeżenia operatora na podstawie skonfigurowanej logiki głosowania.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e176449-09 (3500\/70M)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWejścia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kanały sejsmiczne (prędkość lub przyspieszenie)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePobór mocy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypowo 7,7 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 do +65 stopni Celsjusza\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 do +85 stopni Celsjusza\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% bez kondensacji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,91 kg (2,0 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiody LED statusu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOK, TX\/RX, Bypass\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania dotyczące zastosowań w terenie\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest konkretna korzyść z funkcji Przyspieszenia impulsowego dla jednostek tłokowych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSprężarki tłokowe generują charakterystyczne sygnały impulsowe, gdy elementy mechaniczne, takie jak sworznie głowicy tłoka lub śruby, stają się luźne. Funkcja Przyspieszenia impulsowego 3500\/70M jest dostrojona do wykrywania tych wysokoczęstotliwościowych, krótkotrwałych uderzeń, które standardowy monitoring prędkości może przeoczyć.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy 3500\/70M może być używany w instalacjach w strefach zagrożonych wybuchem?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, w połączeniu z odpowiednimi modułami I\/O z barierą wewnętrzną (takimi jak 135473-01), system jest certyfikowany do stosowania w środowiskach iskrobezpiecznych zgodnie z normami CSA, ATEX i IECEx.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo powoduje zapalenie się diody LED \"Bypass\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDioda Bypass zapala się, gdy jeden lub więcej kanałów ma zablokowaną logikę alarmową. Zwykle jest to wykonywane za pomocą oprogramowania konfiguracyjnego 3500 Rack podczas uruchamiania maszyny lub konserwacji przetworników, aby zapobiec fałszywym alarmom.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWytyczne dotyczące instalacji inżynierskiej i niezawodności\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWybór modułu I\/O:\u003c\/strong\u003e Upewnij się, że 176449-09 jest sparowany z odpowiednim modułem I\/O do stylu zakończenia okablowania. Używaj Internal Termination I\/O (140471-01) do bezpośredniego okablowania szafy lub External Termination I\/O (140482-01), jeśli korzystasz z zewnętrznej listwy zaciskowej.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontaż przetworników sejsmicznych:\u003c\/strong\u003e Do monitorowania drgań głowicy tłoka czujniki sejsmiczne muszą być solidnie zamontowane w kierunku ruchu głowicy. Upewnij się, że powierzchnia montażowa jest płaska i pozbawiona farby, aby zapewnić transmisję sygnału wysokiej częstotliwości.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOkablowanie i ekranowanie:\u003c\/strong\u003e Stosuj wysokiej jakości ekranowane przewody skręcane dla wszystkich wejść sejsmicznych. Aby zapobiec pętlom masy, ekran należy uziemić tylko po stronie uziemienia szafy 3500; nie uziemiać ekranu po stronie przetwornika, chyba że używana jest specjalna izolowana podstawa montażowa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMoment dokręcania i montaż:\u003c\/strong\u003e Podczas instalacji 3500\/70M w szafie, upewnij się, że śruby obudowy są dokręcone tak, aby zapewnić niskooporową ścieżkę uziemienia dla ochrony przed EMI. W przypadku czujników sejsmicznych w terenie stosuj się do określonych wymagań momentu dokręcania dla śrub montażowych 1\/4-28 lub M8, aby uniknąć błędów rezonansowych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516308331,"sku":"3500\/70M 176449-09","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-70m-176449-09-recip-impulse-velocity-monitor-0te3jbc4wu3_55047821-4da1-4958-809a-9be6b9614726.jpg?v=1765440088"},{"product_id":"bently-nevada-184826-01-3500-94m-vga-display-monitor-module","title":"Moduł monitora wyświetlacza VGA Bently Nevada 184826-01 3500\/94M","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e184826-01 (3500\/94M)\u003c\/strong\u003e to wysokowydajny moduł wyświetlacza VGA zaprojektowany dla systemu ochrony maszyn Bently Nevada 3500. Moduł ten służy jako główny interfejs wizualny do monitorowania w czasie rzeczywistym krytycznych obrotowych urządzeń w elektrowniach, rafineriach ropy naftowej oraz zakładach przemysłowych. \u003cstrong\u003e184826-01\u003c\/strong\u003e zapewnia scentralizowaną wizualizację list zdarzeń systemowych, statusów alarmów oraz danych poszczególnych modułów, obsługując do dziewięciu konfigurowalnych ekranów wyświetlacza. Konsolidując pomiary drgań filtrowanych 1X oraz wartości szczelin przetworników zbliżeniowych w intuicyjne wykresy słupkowe i grupy maszyn, umożliwia inżynierom utrzymania ruchu natychmiastowe wykrywanie nieprawidłowego zachowania maszyn. Możliwość współpracy z przemysłowymi ekranami dotykowymi zapewnia lokalnym operatorom natychmiastowy dostęp do danych diagnostycznych, co znacząco skraca średni czas naprawy (MTTR) i zapobiega kosztownym, nieplanowanym przestojom.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e184826-01\u003c\/strong\u003e działa jako zaawansowany agregator danych i sterownik wideo w architekturze szafy 3500.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMożliwości wizualizacji:\u003c\/strong\u003e Potrafi wyświetlać kompleksowe dane szafy, w tym status Alarm\/OK, wartości kanałów oraz strony konfigurowane za pomocą oprogramowania 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpcje łączności:\u003c\/strong\u003e Wyposażony w standardowy port VGA do analogowych sygnałów RGB sync oraz port RS232 do wymiany danych z kontrolerem dotykowym.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDostęp zdalny:\u003c\/strong\u003e Obsługuje bezpośredni montaż do 6 metrów (20 stóp) przy użyciu standardowych kabli. Do monitoringu na duże odległości integruje się z extenderami KVM przez światłowody jednomodowe, osiągając dystanse do 10 kilometrów (6,2 mili) bez utraty jakości obrazu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegracja wieloszafowa:\u003c\/strong\u003e W połączeniu z opcjonalnym Display Router Box pojedynczy interfejs \u003cstrong\u003e3500\/94M\u003c\/strong\u003e może przełączać i wyświetlać dane z maksymalnie czterech oddzielnych szaf 3500.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e184826-01 (3500\/94M)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003emaksymalnie 4,6 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWyjście wideo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePort VGA (analogowy czerwony, zielony, niebieski, synchronizacja)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfejs danych\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 (dane kontrolera dotykowego)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C do 65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C do 85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% bez kondensacji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga monitora\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,73 kg (1,6 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWskaźniki statusu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLEDy OK, TX\/RX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania dotyczące wsparcia technicznego\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest maksymalna zalecana długość kabla bez użycia extendera?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandardowy limit VGA to 6 metrów (20 stóp). Przekroczenie tej odległości przy użyciu standardowego kabla miedzianego zwykle powoduje powidoki, tłumienie sygnału i utratę ostrości obrazu, zwłaszcza w przemysłowych środowiskach o wysokim poziomie zakłóceń elektromagnetycznych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIle niestandardowych ekranów wyświetlacza można skonfigurować?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOprogramowanie 3500 Rack Configuration Software pozwala na zdefiniowanie do dziewięciu unikalnych, niestandardowych ekranów. Mogą one być organizowane według grup maszyn lub konkretnych typów pomiarów (np. wszystkie pozycje osiowe na jednej stronie, wszystkie drgania promieniowe na innej).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy moduł 3500\/94M jest kompatybilny z wyświetlaczami do stref zagrożonych wybuchem?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł sam znajduje się w szafie 3500 (zwykle w strefie bezpiecznej). Jednak jest zaprojektowany do współpracy z 10-calowymi ekranami dotykowymi Advantech, które posiadają certyfikaty do instalacji w środowiskach zagrożonych, pod warunkiem zasilania odpowiednimi zewnętrznymi źródłami zasilania.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWytyczne dla inżynierii terenowej i instalacji\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegralność sygnału wideo:\u003c\/strong\u003e W środowiskach o wysokich zakłóceniach stosuj podwójnie ekranowane kable VGA. Upewnij się, że \u003cstrong\u003e184826-01\u003c\/strong\u003e jest solidnie osadzony w szafie, aby utrzymać stabilną, szybką komunikację sieciową z modułem interfejsu szafy (RIM).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZasilanie i integracja dotyku:\u003c\/strong\u003e Przedni port zapewnia wyjście zasilania 24 VDC i odbiera polecenia dotykowe. Podczas okablowania zdalnego ekranu dotykowego sprawdź polaryzację wyjścia 24 VDC, aby zapobiec uszkodzeniu kontrolera dotyku wyświetlacza.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZdalny monitoring przez KVM:\u003c\/strong\u003e Przy użyciu extendera SM FO KVM na odległości do 10 km nadajnik i odbiornik muszą być zainstalowane w strefie bezpiecznej lub w obudowie o odpowiednim stopniu ochrony IP, ponieważ te komponenty nie są certyfikowane do bezpośredniej ekspozycji w strefach zagrożonych wybuchem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptymalizacja ekranów niestandardowych:\u003c\/strong\u003e Dla skutecznej ochrony maszyn skonfiguruj domyślny ekran „Home” tak, aby wyświetlał listę zdarzeń systemowych. Zapewnia to, że każdy status „Nie OK” lub alarm „First Out” jest natychmiast widoczny dla operatora bez konieczności nawigacji po podmenu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516406635,"sku":"3500\/94M 184826-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-94m-184826-01-vga-display-monitor-euhoqkcrnp1_151c7d07-3acd-4e8e-9422-78b4d7366e15.jpg?v=1765440090"},{"product_id":"bently-nevada-285694-02-3500-61e-6-channel-temperature-monitor","title":"Bently Nevada 285694-02 3500\/61E 6-kanałowy monitor temperatury","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e285694-02 (3500\/61E)\u003c\/strong\u003e\u003c\/span\u003e to wysokoprecyzyjny, sześciokanałowy moduł monitorowania temperatury zaprojektowany dla systemu ochrony maszyn Bently Nevada 3500 ENCORE. Głównie wykorzystywany w ciężkich turbinach gazowych, turbinach parowych oraz dużych sprężarkach w sektorach energetycznym i naftowym, moduł ten zapewnia kluczową ochronę uzwojeń silników i temperatur łożysk. Poprzez ciągłe przetwarzanie sygnałów z czujników rezystancyjnych (RTD) i porównywanie ich z programowalnymi przez użytkownika progami Alarmu i Niebezpieczeństwa, \u003cspan\u003e\u003cstrong\u003e285694-02\u003c\/strong\u003e\u003c\/span\u003e gwarantuje wykrycie przekroczeń termicznych zanim dojdzie do katastrofalnej awarii mechanicznej. Jego zdolność do integracji zarówno z modernizacjami szaf 3300, jak i nowoczesnymi szafami systemu ENCORE czyni go wszechstronnym rozwiązaniem zmniejszającym przestoje zakładu i wydłużającym żywotność obracających się urządzeń.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e285694-02\u003c\/strong\u003e\u003c\/span\u003e jest skonfigurowany jako nieizolowany monitor RTD, zoptymalizowany do wysokiej gęstości pomiarów termicznych, gdzie standardem są czujniki platynowe 3- lub 4-przewodowe.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWszechstronność czujników:\u003c\/strong\u003e Obsługuje RTD platynowe 100 Ohm (alpha = 0,00385 lub 0,00392), niklowe 120 Ohm oraz miedziane 10 Ohm. Platynowy RTD (0,00385) jest zalecanym światowym standardem przemysłowym dla najwyższej dokładności.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdaptacja systemowa:\u003c\/strong\u003e W trybie „Rack Upgrade” współpracuje z istniejącymi modułami I\/O i przekaźnikami serii 3300. W trybie „System ENCORE” wykorzystuje programowalne logicznie moduły przekaźnikowe do sterowania alarmami.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegralność sygnału:\u003c\/strong\u003e Zapewnia dedykowane źródło prądu 913 mikroamperów na każdy przetwornik (pojedyncze zasilanie dla 4-przewodowych, podwójne dla 3-przewodowych), co gwarantuje stabilny pomiar rezystancji na długich odcinkach kabli.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWidoczność operacyjna:\u003c\/strong\u003e Wyposażony w diody LED na przednim panelu sygnalizujące status OK, Alarm, Niebezpieczeństwo oraz Bypass, zapewniając natychmiastową lokalną diagnostykę dla personelu utrzymania ruchu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e285694-02 (3500\/61E)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp wejścia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-kanałowy RTD (rezystancyjny czujnik temperatury)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKompatybilność RTD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatyna 100 Ohm, Nikiel 120 Ohm, Miedź 10 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePobór mocy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5,6 W nominalnie (opcja RTD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWyjście rejestratora\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 do 20 mA (indywidualne dla każdego kanału)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRozdzielczość\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1°C lub 1°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDokładność (platyna)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±1°C maksymalnie (zakres ograniczony do 150°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C do +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWiększa niż 3 MΩ dla każdego przewodu\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKompatybilność napięciowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZakres 0 do +12 VDC na obciążeniu (0 do 600 Ohm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania inżynierskie\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJak 3500\/61E radzi sobie z instalacjami „Rack Upgrade” a „Full System”?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eW trybie Rack Upgrade 3500\/61E zastępuje monitor 3300\/30 lub 3300\/35, korzystając z oryginalnych modułów I\/O i przekaźników 3300. W pełnym systemie ENCORE wykorzystuje nowe moduły I\/O temperatury ENCORE oraz programowalny moduł przekaźnikowy do sterowania alarmami.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy moduł wymaga kalibracji w terenie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie. Wszystkie parametry konfiguracyjne ustawia się za pomocą oprogramowania 3500 Rack Configuration Software. Wysokoprecyzyjne wewnętrzne układy modułu eliminują potrzebę ręcznej kalibracji w terenie po określeniu typu i zakresu przetwornika.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest wpływ zwarcia na wyjścia rejestratora?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePraca monitora nie jest w żaden sposób zakłócona przez zwarcia na wyjściach rejestratora 4 do 20 mA. Takie rozwiązanie gwarantuje, że awaria linii sygnałowej DCS\/PLC nie wpłynie na podstawową logikę ochrony maszyn.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWytyczne instalacyjne i porady inżynierskie\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecyzja okablowania RTD:\u003c\/strong\u003e W instalacjach 3-przewodowych RTD należy zapewnić, aby wszystkie trzy przewody miały niemal identyczną rezystancję i były prowadzone razem. \u003cspan\u003e\u003cstrong\u003e285694-02\u003c\/strong\u003e\u003c\/span\u003e wykorzystuje dwa źródła prądu do kompensacji 3-przewodowej; znaczna nierównowaga rezystancji przewodów może wprowadzać błędy pomiaru temperatury, prowadząc do fałszywych wyłączeń.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUwagi dotyczące barier:\u003c\/strong\u003e Przy stosowaniu zewnętrznych barier bezpieczeństwa iskrobezpiecznego należy pamiętać, że dolny limit „OK” czujnika jest zwykle ograniczony do -50°C. Należy odpowiednio dostosować oprogramowanie 3500 Configuration Software, uwzględniając dodatkową rezystancję barier, aby zachować dokładność pomiaru.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZarządzanie logiką przekaźników:\u003c\/strong\u003e W konfiguracji systemu ENCORE \u003cspan\u003e\u003cstrong\u003e3500\/61E\u003c\/strong\u003e\u003c\/span\u003e nie posiada wbudowanych przekaźników. Musi być przypisany do modułu przekaźnikowego 3500. Należy upewnić się, że status „Bypass” monitora jest poprawnie odzwierciedlony w logice blokad bezpieczeństwa zakładu podczas prac konserwacyjnych, aby zapobiec pracy „na ślepo”.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNajlepsze praktyki ekranowania:\u003c\/strong\u003e Aby zminimalizować zakłócenia elektromagnetyczne (EMI) na sygnałach niskiego poziomu RTD, stosuj ekranowane kable skrętkowe. Ekrany należy uziemiać tylko na szynie uziemiającej szafy 3500, aby uniknąć pętli masy, które mogą powodować „dryft” sygnału lub nieregularne wyzwalanie alarmów Alert\/Niebezpieczeństwo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516668779,"sku":"3500\/61E 285694-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61e-285694-02-temperature-monitor-f3g3ccfvs2b_d717d800-41d8-4ef7-ba75-cc9da7657211.jpg?v=1765440094"},{"product_id":"bently-nevada-176449-02-3500-42m-proximitor-seismic-monitor","title":"Bently Nevada 176449-02 3500\/42M Proximitor Monitor Sejsmiczny","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e176449-02 (3500\/42M)\u003c\/strong\u003e\u003c\/span\u003e to wysokowydajny czterokanałowy monitor drgań zaprojektowany dla systemu ochrony maszyn Bently Nevada 3500. Przeznaczony do krytycznych urządzeń w energetyce, przemyśle naftowym i gazowym oraz ciężkim przemyśle wytwórczym, moduł ten akceptuje sygnały z przetworników zbliżeniowych, prędkości i przyspieszenia. Jego główną rolą jest ciągła ochrona maszyn poprzez porównywanie na żywo danych o drganiach z ustawionymi przez użytkownika progami alarmowymi. Dzięki wykrywaniu wczesnych oznak niewyważenia wału, zużycia łożysk lub niewyważenia, \u003cspan\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e\u003c\/span\u003e umożliwia zespołom utrzymania ruchu przeprowadzanie działań predykcyjnych, skutecznie eliminując katastrofalne awarie maszyn i znacznie redukując nieplanowane przestoje zakładu.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003eMonitor 3500\/42M wykorzystuje architekturę z dwoma parami kanałów, co pozwala na elastyczne strategie monitorowania w pojedynczym slocie szafy.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgramowanie kanałów:\u003c\/strong\u003e Kanały są konfigurowane parami (1\/2 i 3\/4), obsługując jednoczesne funkcje. Na przykład jedna para może monitorować drgania promieniowe, podczas gdy druga para śledzi pozycję osi lub przyspieszenie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGenerowanie wartości statycznych:\u003c\/strong\u003e Moduł przetwarza surowe sygnały z przetworników na parametry operacyjne, takie jak Direct, Gap, 1X i 2X Vector, Smax oraz Eccentricity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogika filtracji:\u003c\/strong\u003e Wyposażony w programowalne filtry jednobiegunowe (4 Hz do 4000 Hz) oraz filtry notch o stałej Q dla monitorowania \"Not 1X\" i wektorów, zapewnia wysoką jakość sygnału nawet w hałaśliwym środowisku.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuforowane wyjścia:\u003c\/strong\u003e Koaksjalne złącza na przednim panelu zapewniają zabezpieczone przed zwarciem sygnały buforowane dla każdego kanału, umożliwiając bezpośrednie podłączenie do zewnętrznych analizatorów częstotliwości lub rejestratorów bez przerywania pętli ochrony.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e176449-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePobór mocy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7,7 W typowo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kOhm (standardowe I\/O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZasilanie przetwornika\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWyjście rejestratora\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 do 20 mA (indywidualne dla każdego kanału)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOpór obciążenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 do 600 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 do +65 stopni Celsjusza\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePasmo przenoszenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Hz do 4000 Hz (programowalne przez użytkownika)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania dotyczące serwisu w terenie\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCo oznaczają diody LED na przednim panelu w kontekście stanu systemu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDioda OK wskazuje pomyślne przejście diagnostyki wewnętrznej 3500\/42M. Dioda TX\/RX miga, potwierdzając aktywną komunikację szeregową z modułem interfejsu szafy (RIM), natomiast dioda Bypass świeci, gdy monitor jest w trybie Bypass, co oznacza, że logika alarmowa jest wyłączona.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy monitor 3500\/42M może jednocześnie przetwarzać różne typy przetworników?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, ponieważ kanały są programowane parami, można monitorować sygnały Proximitor na jednej parze, a sygnały sejsmiczne (prędkość\/przyspieszenie) na drugiej, pod warunkiem, że mieszczą się w obsługiwanym zakresie sygnału -24 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo się stanie, jeśli wyjście rejestratora zostanie zwarte?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePraca monitora i logika ochrony pozostają całkowicie nienaruszone przez zwarcia na wyjściach rejestratora 4-20 mA. Moduł posiada wewnętrzne zarządzanie zgodnością napięciową, które utrzymuje integralność sygnału w całym zakresie obciążenia.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWytyczne dotyczące instalacji i uruchomienia inżynieryjnego\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEkranowanie i uziemienie:\u003c\/strong\u003e Zawsze zakończ osłony kabli sygnałowych na zaciskach uziemienia modułu I\/O systemu 3500. Nigdy nie uziemiać osłony na obu końcach, ponieważ powoduje to pętle masy, które mogą zakłócać czułe sygnały drgań.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKorekta napięcia szczeliny:\u003c\/strong\u003e W zastosowaniach z sondami zbliżeniowymi zweryfikuj wartość statyczną \"Gap\" podczas instalacji. Upewnij się, że sonda jest ustawiona w liniowym zakresie przetwornika (zazwyczaj -10 VDC dla standardowych sond 8 mm), aby zapobiec przesterowaniu sygnału i utrzymać dokładne progi alarmowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegralność okablowania:\u003c\/strong\u003e Upewnij się, że opór obciążenia wyjść rejestratora 4-20 mA nie przekracza 600 Ohm. Przekroczenie tego limitu spowoduje nasycenie sygnału, co skutkuje niedokładnym raportowaniem do DCS lub PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZarządzanie termiczne:\u003c\/strong\u003e Przy użyciu monitora w konfiguracjach o wysokiej gęstości w pobliżu limitu 65 stopni Celsjusza zapewnij odpowiednią wentylację szafy. Długotrwała praca w temperaturach szczytowych może pogorszyć dokładność rozdzielczości 4-20 mA (z 0,25% w temperaturze pokojowej do 0,7% przy granicznych temperaturach).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516734315,"sku":"3500\/42M 176449-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42m-176449-02-proximitor-seismic-monitor-k32jvb2xqxe_b0d50d43-00a9-4728-9846-a30a23c88b20.jpg?v=1765440095"},{"product_id":"bently-nevada-3500-50m-286566-02-tachometer-module","title":"Bently Nevada 3500\/50M 286566-02 Tachometer Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/50M 286566-02 \u003c\/strong\u003eis a high-performance, dual-channel tachometer module designed for the Bently Nevada 3500 Machinery Protection System.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e Deployed globally across heavy industries including thermal power plants, oil refineries, and large-scale mining operations, this module processes inputs from passive magnetic pickups or proximity probes to provide precision shaft speed, rotor acceleration, and reverse rotation indicators. By continuously cross-referencing live data with programmable alarm setpoints, it executes instantaneous alarm generation to prevent catastrophic overspeed events. The module drastically reduces plant downtime by providing stable, conditioned Keyphasor signals straight to the rack backplane, eliminating the need for dedicated Keyphasor hardware in the same rack enclosure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e286566-02 \u003c\/strong\u003efunctions as a primary processing card within the 3500\/50M tachometer architecture, delivering dual-channel sensor processing and independent configuration options via the 3500 Rack Configuration software.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpeed Tracking Modes:\u003c\/strong\u003eSupports standard speed monitoring, multi-band speed alarming, zero-speed alerts, rotor acceleration tracking, and reverse rotation notification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePeak Data Logging:\u003c\/strong\u003eFeatures an on-board peak hold capability that permanently logs maximum forward speed, maximum reverse speed, and cumulative reverse rotation events until a manual or remote reset command is given.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Interconnectivity:\u003c\/strong\u003e Routes internal conditioned Keyphasor pulses across the rack backplane, enabling simultaneous multi-channel phase tracking for adjacent vibration monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Interface:\u003c\/strong\u003e Features front-panel buffered transducer outputs via coaxial connections alongside dedicated LEDs indicating module OK status, active serial communication TX\/RX, and system bypass state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/50M 286566-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Independent Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10.0 VDC to -24.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kOhm (Standard) \/ 40 kOhm (TMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity Probes, Passive Magnetic Pickups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 99999 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Accuracy (\u0026lt; 100 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Accuracy (100 to 10000 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Accuracy (\u0026gt; 10000 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.01% of true shaft speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Recorder Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e244.3 mm x 24.4 mm x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 3500\/50M 286566-02 module be hot-swapped while the 3500 system is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 3500\/50M tachometer card is designed for live insertion and removal within a powered 3500 rack. However, to prevent unintended trip signals on downstream machinery control components, the operator must place the associated protection loops or relay outputs into bypass before pulling the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module determine the threshold for passive magnetic pickups versus proximity probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module configuration software allows operators to toggle between Auto Threshold and Manual Threshold modes. Auto Threshold works for any speed input above 1 rpm (0.0167 Hz) with a minimum peak-to-peak amplitude of 1 volt. Manual Threshold allows direct adjustment from +9.5 VDC down to -23.5 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat indicates a catastrophic internal circuit failure versus a sensor line fault?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe front-panel OK LED will turn off completely or flash erratically if internal hardware diagnostics fail. If the fault resides in the field wiring or probe tip gap, the OK LED will illuminate red, indicating a Not OK field transducer status, while the internal data registers switch to an invalid data flag state.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Safety Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Cable Shielding:\u003c\/strong\u003e Terminate all external proximity sensor or magnetic pickup shields at the 3500 system's I\/O module ground bus terminal bar. Never ground the shield at both ends to ensure ground loops do not corrupt high-frequency pulse inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Output Isolation:\u003c\/strong\u003e The front-panel coaxial buffered outputs are short-circuit protected. Technicians can hook up portable vibration data collectors or external frequency analyzers directly to the front face without interrupting the machinery protection loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Wheel Design Parameters:\u003c\/strong\u003e Ensure the speed sensing target wheel or keyway conforms to the 3500\/50M technical manual specifications. The configuration must be set precisely between 1 and 255 events per revolution to guarantee accurate acceleration computations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Output Calibration:\u003c\/strong\u003e When using the 4 to 20 mA recorder outputs for DCS speed replication, verify that the load resistance does not exceed 600 Ohms to prevent signal clipping and maintain calibration linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517061995,"sku":"3500\/50M 286566-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-50m-286566-02-tachometer-module-upbl1e2kq5e_ee299714-908e-4209-8aca-8be34c14b831.jpg?v=1765440101"},{"product_id":"bently-nevada-3500-65-145988-02-16-channel-temperature-monitor","title":"Bently Nevada 3500\/65 145988-02 16-kanałowy monitor temperatury","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eMonitor \u003cstrong\u003eBently Nevada 3500\/65\u003c\/strong\u003e, wykorzystujący główny moduł \u003cstrong\u003e145988-02\u003c\/strong\u003e, to wysokogęstościowy \u003cstrong\u003e16-kanałowy monitor temperatury\u003c\/strong\u003e zaprojektowany do ochrony krytycznych maszyn przemysłowych poprzez ciągłe śledzenie termiczne. Ten specjalistyczny moduł przyjmuje 16 kanałów sygnałów temperatury zarówno z czujników RTD, jak i izolowanych termopar (TC). Wewnętrznie przetwarza te surowe sygnały przetworników i nieustannie porównuje je z zaprogramowanymi przez użytkownika progami alarmowymi i niebezpieczeństwa, aby zapobiec termicznemu uszkodzeniu kluczowych zasobów zakładu.\u003c\/p\u003e\n\u003cp\u003eKonfiguracja i mapowanie kanałów odbywają się za pomocą \u003cstrong\u003eoprogramowania do konfiguracji szafy 3500\u003c\/strong\u003e. Operatorzy mogą płynnie programować architekturę 16-kanałową do przetwarzania izolowanych termopar, czujników RTD 3-przewodowych, RTD 4-przewodowych lub kombinacji obu typów czujników w tym samym slocie obudowy. W środowiskach o wysokiej integralności wymagających bezpieczeństwa typu Triple Modular Redundant (TMR), monitory muszą być stosowane w grupach po 3 sąsiadujące jednostki w szafie \u003cstrong\u003esystemu ochrony maszyn serii 3500\u003c\/strong\u003e. W tej konfiguracji system stosuje dwupoziomową logikę głosowania, aby zapewnić dokładność działania i zminimalizować ryzyko awarii pojedynczego punktu.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrzetwarza do 16 niezależnych wejść czujników temperatury w pojedynczym slocie szafy.\u003c\/li\u003e\n\u003cli\u003eUniwersalny przydział kanałów akceptuje mieszane konfiguracje termopar (TC), czujników RTD 3-przewodowych i RTD 4-przewodowych.\u003c\/li\u003e\n\u003cli\u003eBezpośrednia kompatybilność z \u003cstrong\u003eoprogramowaniem do konfiguracji szafy 3500\u003c\/strong\u003e do modyfikacji w terenie.\u003c\/li\u003e\n\u003cli\u003eWdraża dwupoziomową logikę głosowania wewnętrznego, gdy jest grupowany w zestawy po trzy dla architektur ochrony bezpieczeństwa TMR.\u003c\/li\u003e\n\u003cli\u003eWysoka szybkość zbierania danych, aktualizująca wszystkie kanały w odstępie 1 sekundy.\u003c\/li\u003e\n\u003cli\u003eWyraźne diody LED na przednim panelu umożliwiające natychmiastową ocenę statusu walidacji sprzętu (OK), statusu komunikacji szafy (TX\/RX) oraz statusu obejścia.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWielopunktowe śledzenie temperatury łożysk w turbinach parowych i gazowych o wysokich obrotach.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie termiczne uzwojeń stojana i obudowy silnika w ciężkich urządzeniach do wytwarzania energii.\u003c\/li\u003e\n\u003cli\u003eNadzór temperatury gazów procesowych i smarów w wielostopniowych sprężarkach odśrodkowych.\u003c\/li\u003e\n\u003cli\u003eOchrona cieplna kotłów, pomp i maszyn pomocniczych w instalacjach petrochemicznych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e145988-02: Monitor 3500\/65\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUSA\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e3 W nominalnie\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eWejścia sygnałowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1 do 16 sygnałów przetworników RTD lub termopar z izolowaną końcówką\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eWiększa niż 1 MOhm dla każdego wejścia przewodu\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eTypy i zakresy termopar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eTyp E: -100°C do +1000°C (-148°F do +1832°F)\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eTyp J: 0°C do +760°C (32°F do +1400°F)\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eTyp K: 0°C do +1370°C (32°F do +2498°F)\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eTyp T: -160°C do +400°C (-256°F do +752°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eTypy i zakresy RTD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e100 Ohm 3- i 4-przewodowy platynowy (alpha = 0,00385): -200°C do +850°C (-328°F do +1562°F)\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e100 Ohm 3- i 4-przewodowy platynowy (alpha = 0,00392): -200°C do +700°C (-328°F do +1292°F)\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e120 Ohm 3- i 4-przewodowy niklowy: -80°C do +260°C (-112°F do +500°F)\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e10 Ohm 3- i 4-przewodowy miedziany: -100°C do +260°C (-148°F do +500°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eWartość źródła prądu RTD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e913 +\/- 7 uA przy 25°C na przetwornik (1 zasilanie dla RTD 4-przewodowego, 2 zasilania dla RTD 3-przewodowego)\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eRozdzielczość\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1°C lub 1°F\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eDokładność wewnętrznego zakończenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eSzafa z przepustem: +\/-3°C przy +25°C (+\/-5,4°F przy +77°F)\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eStandardowa szafa: +\/-3°C przy +25°C (+\/-5,4°F przy +77°F)\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eDokładność zewnętrznego zakończenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eSzafa z przepustem: +\/-3°C przy +25°C (+\/-5,4°F przy +77°F)\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eStandardowa szafa: +\/-3°C przy +25°C (+\/-5,4°F przy +77°F)\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eDokładność czujnika kompensacji złącza zimnego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e+\/-2°C przy +25°C (+\/-3,6°F przy +77°F)\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eWymiary głównego modułu (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e0,91 kg (2,0 lbs)\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eTyp złącza\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eWewnętrzny złącze tylnej płyty podwozia\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIntegruje trasowanie zasilania i szybkie komunikacje danych z magistralą szafy 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eZewnętrzne bloki zakończeniowe \/ moduł I\/O\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBezpośredni fizyczny interfejs dla 16 niezależnych przewodów czujników RTD i termopar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyrównanie TMR:\u003c\/strong\u003e Podczas konfigurowania układu Triple Modular Redundant, zainstaluj indywidualne monitory temperatury w grupach po trzy przylegające do siebie sloty strukturalne.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOgraniczenia wyboru czujnika:\u003c\/strong\u003e Upewnij się, że wszystkie podłączone termopary są typu z izolowaną końcówką, aby uniknąć zakłóceń pętli masy wspólnej między kanałami.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePraktyki okablowania:\u003c\/strong\u003e Używaj ekranowanego, skręcanego przewodu polowego dla wszystkich połączeń RTD i termopar, aby zminimalizować wpływ indukcji elektromagnetycznej z otoczenia.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegralność uziemienia ekranu:\u003c\/strong\u003e Utrzymuj ciągłość ekranowania kabla aż do bloków zaciskowych, uziemiając ekrany tylko w wyznaczonym punkcie wspólnym obudowy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZarządzanie termiczne:\u003c\/strong\u003e Sprawdź, czy temperatura otoczenia pracy nie przekracza 65°C, aby zapewnić zgodność z określonymi parametrami wewnętrznej kompensacji zimnego złącza.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest podstawowa funkcja modułu 3500\/65?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMonitoruje do 16 kanałów temperatury maszyn zakładowych za pomocą wejść RTD i izolowanych termopar.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten monitor temperatury może przyjmować termopary nieizolowane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, moduł jest specjalnie przystosowany do przyjmowania tylko izolowanych termopar, aby zapobiec błędom sygnału.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie narzędzie konfiguracyjne jest używane do ustawiania progów alarmowych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWszystkie regulacje parametrów, wybór czujników i konfiguracje alarmów wymagają oprogramowania 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo oznacza stale świecąca dioda Bypass na przednim panelu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOznacza to, że monitor został celowo przełączony w tryb Bypass, co powoduje tłumienie zaprogramowanych działań wyjściowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest zalecana konfiguracja czujnika dla standardowych instalacji przemysłowych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlatynowe czujniki RTD o wartości alfa 0,00385 są standardem branżowym i zalecane do zastosowań ogólnych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak system działa, gdy jest używany w aplikacji TMR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMonitor musi być instalowany w grupach po trzy sąsiednie sloty w szafie i wykorzystuje dwa różne typy głosowania, aby zapobiec awariom pojedynczego punktu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy dla tego urządzenia wymagana jest ręczna kalibracja w terenie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie jest wymagana ręczna kalibracja w terenie, ponieważ funkcje kondycjonowania sygnału są wstępnie ustawione i zarządzane przez wewnętrzne skalowanie oprogramowania.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie są poziomy impedancji wejściowej na przewód?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eImpedancja wejściowa wynosi ponad 1 MΩ dla każdego niezależnego przewodu wejściowego.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest stała wartość prądu dostarczana do pomiarów RTD?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZintegrowane źródło prądu dostarcza 913 +\/- 7 µA przy 25°C na element przetwornika.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIle wewnętrznych źródeł prądu jest używanych, gdy podłączony jest czujnik RTD 3-przewodowy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSprzęt wykorzystuje dwa oddzielne źródła prądu dla konfiguracji 3-przewodowej RTD oraz jedno źródło dla konfiguracji 4-przewodowej RTD.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517225835,"sku":"3500\/65 145988-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-65-145988-02-16-channel-temperature-monitor-m4kmh1qtud2_5fbc0b52-b118-4204-902d-d60ea44fb72e.jpg?v=1765440103"},{"product_id":"bently-nevada-3500-64m-176449-05-dynamic-pressure-monitor-module","title":"Moduł monitorowania ciśnienia dynamicznego Bently Nevada 3500\/64M 176449-05","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/64M 176449-05\u003c\/strong\u003e Jest to czterokanałowy moduł monitorowania ciśnienia dynamicznego zaprojektowany do ciągłej ochrony maszyn i monitorowania procesów. Przyjmuje sygnały wejściowe z wysokotemperaturowych przetworników ciśnienia i przetwarza pomiary ciśnienia dynamicznego do analizy drgań i pulsacji ciśnienia w systemach maszyn wirujących.\u003c\/p\u003e\n\u003cp\u003eMonitor obsługuje konfigurowalne filtrowanie pasmowe, filtry zaporowe oraz wyjścia rejestratora do integracji z systemami sterowania zakładu. Każdy kanał może generować niezależnie konfigurowane zmienne pomiarowe, poziomy ostrzegawcze i alarmy niebezpieczeństwa za pomocą oprogramowania 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor ciśnienia dynamicznego 3500\/64M 176449-05\u003c\/strong\u003e nieustannie porównuje zmierzone wartości z skonfigurowanymi progami alarmowymi, wspierając funkcje ochrony maszyn oraz dostarczając informacje diagnostyczne dla personelu operacyjnego i utrzymania ruchu.\u003c\/p\u003e\n\u003cp\u003eModuł obsługuje przetworniki ciśnienia 2- i 3-przewodowe oraz może pracować w trybie kaskadowym, pozwalając na zasilanie wszystkich czterech kanałów monitorujących z jednego wejścia przetwornika z różnymi konfiguracjami filtrów i zakresami pełnej skali.\u003c\/p\u003e\n\u003cp\u003eTypowe instalacje obejmują turbiny, sprężarki, pompy, wentylatory i inne krytyczne maszyny wirujące wymagające monitorowania ciśnienia dynamicznego w systemach ochrony maszyn \u003cstrong\u003eBently Nevada 3500 Series\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCzterokanałowe monitorowanie ciśnienia dynamicznego\u003c\/li\u003e\n\u003cli\u003eModuł szafy 3500 na jedno miejsce\u003c\/li\u003e\n\u003cli\u003eObsługuje od 1 do 4 wejść przetworników ciśnienia\u003c\/li\u003e\n\u003cli\u003eKompatybilny z przetwornikami 2- i 3-przewodowymi\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne filtrowanie pasmowe\u003c\/li\u003e\n\u003cli\u003eZintegrowany wybór filtra zaporowego\u003c\/li\u003e\n\u003cli\u003eDystrybucja sygnału w trybie kaskadowym\u003c\/li\u003e\n\u003cli\u003eBuforowane wyjścia przetworników\u003c\/li\u003e\n\u003cli\u003eWyjścia rejestratora dla systemów sterowania\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne alarmy ostrzegawcze i niebezpieczeństwa\u003c\/li\u003e\n\u003cli\u003eDiody LED diagnostyczne na panelu przednim\u003c\/li\u003e\n\u003cli\u003eWsparcie oprogramowania konfiguracji szafy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSprężarki odśrodkowe\u003c\/li\u003e\n\u003cli\u003eTurbiny parowe i gazowe\u003c\/li\u003e\n\u003cli\u003ePompy przemysłowe\u003c\/li\u003e\n\u003cli\u003eWentylatory i dmuchawy procesowe\u003c\/li\u003e\n\u003cli\u003eSystemy ochrony maszyn wirujących\u003c\/li\u003e\n\u003cli\u003eMonitorowanie pulsacji ciśnienia dynamicznego\u003c\/li\u003e\n\u003cli\u003eMonitorowanie niestabilności spalania\u003c\/li\u003e\n\u003cli\u003eSystemy diagnostyki maszyn\u003c\/li\u003e\n\u003cli\u003eMonitorowanie krytycznych zasobów\u003c\/li\u003e\n\u003cli\u003eIntegracja z kontrolą procesów\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eKategoria\u003c\/th\u003e\n\u003cth\u003eSpecyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp produktu\u003c\/td\u003e\n\u003ctd\u003eMonitor ciśnienia dynamicznego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeria\u003c\/td\u003e\n\u003ctd\u003eSeria 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/64M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer części zamiennej\u003c\/td\u003e\n\u003ctd\u003e176449-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKanały wejściowe\u003c\/td\u003e\n\u003ctd\u003e1 do 4 sygnałów przetwornika ciśnienia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMierzona zmienna\u003c\/td\u003e\n\u003ctd\u003eBezpośrednie ciśnienie dynamiczne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCzułość\u003c\/td\u003e\n\u003ctd\u003e100 mV\/psi (1,45 mV\/mBar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWyjście rejestratora\u003c\/td\u003e\n\u003ctd\u003e+4 do +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpór obciążenia wyjścia rejestratora\u003c\/td\u003e\n\u003ctd\u003e0 do 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRozdzielczość wyjścia rejestratora\u003c\/td\u003e\n\u003ctd\u003e0,3662 µA na bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCzęstotliwość aktualizacji wyjścia rejestratora\u003c\/td\u003e\n\u003ctd\u003eOkoło 100 ms lub mniej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNapięcie zgodności\u003c\/td\u003e\n\u003ctd\u003e0 do +12 V DC na obciążeniu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZasilanie przetwornika 3-przewodowego\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZasilanie przetwornika 2-przewodowego\u003c\/td\u003e\n\u003ctd\u003eŹródło prądowe 3,3 mA przy nominalnym 22 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedancja wyjścia buforowanego\u003c\/td\u003e\n\u003ctd\u003e550 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedancja wejściowa przetwornika 3-przewodowego\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedancja wejściowa przetwornika 2-przewodowego\u003c\/td\u003e\n\u003ctd\u003eTypowo 1,5 MΩ do 3,5 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres filtra trybu niskiego\u003c\/td\u003e\n\u003ctd\u003e5 Hz do 4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRozszerzony zakres trybu niskiego\u003c\/td\u003e\n\u003ctd\u003eOkoło 5,285 kHz bez filtra dolnoprzepustowego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres filtra trybu wysokiego\u003c\/td\u003e\n\u003ctd\u003e10 Hz do 14,75 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJakość filtra górnoprzepustowego\u003c\/td\u003e\n\u003ctd\u003e10-biegunowy, 200 dB na dekadę, 60 dB na oktawę\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJakość filtra dolnoprzepustowego\u003c\/td\u003e\n\u003ctd\u003e10-biegunowy, 200 dB na dekadę, 60 dB na oktawę\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJakość filtra trybu wysokiego\u003c\/td\u003e\n\u003ctd\u003e6-biegunowy, 120 dB na dekadę, 36 dB na oktawę\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltr tłumiący linię zasilającą\u003c\/td\u003e\n\u003ctd\u003eWybór 50 Hz lub 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres nastawy alarmu\u003c\/td\u003e\n\u003ctd\u003e0 do 100% pełnej skali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDokładność alarmu\u003c\/td\u003e\n\u003ctd\u003eW granicach 0,13% wartości docelowej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpóźnienie alarmu\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpóźnienie niebezpieczeństwa\u003c\/td\u003e\n\u003ctd\u003e0,1 sekundy lub 1 do 60 sekund\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary modułu monitorującego\u003c\/td\u003e\n\u003ctd\u003eWymiary modułu monitorującego: 241,3 mm x 24,4 mm x 241,8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga modułu monitorującego\u003c\/td\u003e\n\u003ctd\u003e0,82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary modułu I\/O bez bariery\u003c\/td\u003e\n\u003ctd\u003eWymiary modułu I\/O bez bariery: 241,3 mm x 24,4 mm x 99,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga modułu I\/O bez bariery\u003c\/td\u003e\n\u003ctd\u003e0,20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary modułu I\/O z barierą\u003c\/td\u003e\n\u003ctd\u003eWymiary modułu I\/O z barierą: 241,3 mm x 24,4 mm x 163,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga modułu I\/O z barierą\u003c\/td\u003e\n\u003ctd\u003e0,46 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePin złącza\u003c\/th\u003e\n\u003cth\u003eFunkcja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZłącza koncentryczne na panelu przednim\u003c\/td\u003e\n\u003ctd\u003eBuforowane wyjścia przetworników dla każdego kanału\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWyjścia rejestratora\u003c\/td\u003e\n\u003ctd\u003eAnalogowe wyjście +4 do +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfejs przetwornika 2-przewodowego\u003c\/td\u003e\n\u003ctd\u003eWejście sygnału ciśnienia dynamicznego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfejs przetwornika 3-przewodowego\u003c\/td\u003e\n\u003ctd\u003eWejście sygnału ciśnienia dynamicznego z zewnętrznym zasilaniem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTryb kaskadowy\u003c\/td\u003e\n\u003ctd\u003ePrzekierowuje wejście kanału 1 do wszystkich czterech kanałów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDioda LED TX\/RX\u003c\/td\u003e\n\u003ctd\u003eStatus komunikacji szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDioda LED OK\u003c\/td\u003e\n\u003ctd\u003eStatus pracy modułu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDioda LED obejścia\u003c\/td\u003e\n\u003ctd\u003eWskazuje tryb obejścia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZainstaluj moduł w kompatybilnym slocie szafy \u003cstrong\u003eserii 3500\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eZweryfikuj poprawne okablowanie przetwornika przed podłączeniem zasilania.\u003c\/li\u003e\n\u003cli\u003eUżywaj ekranowanych kabli sygnałowych do połączeń przetworników.\u003c\/li\u003e\n\u003cli\u003eOddziel przewody sygnałów niskiego poziomu od kabli zasilających wysokiego napięcia.\u003c\/li\u003e\n\u003cli\u003eUtrzymuj właściwe uziemienie, aby zmniejszyć zakłócenia elektromagnetyczne i szumy.\u003c\/li\u003e\n\u003cli\u003ePotwierdź ustawienia konfiguracji filtrów przed uruchomieniem.\u003c\/li\u003e\n\u003cli\u003eUżywaj odpowiedniej wentylacji wewnątrz szafy sterowniczej.\u003c\/li\u003e\n\u003cli\u003eSprawdź, czy rezystancja obciążenia wyjścia rejestratora nie przekracza określonych limitów.\u003c\/li\u003e\n\u003cli\u003eZabezpiecz buforowane wyjścia koncentryczne, aby zapobiec przerwom sygnału.\u003c\/li\u003e\n\u003cli\u003eSkonfiguruj opóźnienia alarmów i zagrożeń zgodnie z wymaganiami ochrony maszyn.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNumer części: 176449-05\u003c\/li\u003e\n\u003cli\u003eOpis: 176449-05 3500\/64M Monitor dynamicznego ciśnienia\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest funkcja modułu 3500\/64M 176449-05?\u003c\/strong\u003e\u003cbr\u003eMonitoruje dynamiczne sygnały ciśnienia do ochrony maszyn i monitorowania stanu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIle kanałów obsługuje monitor?\u003c\/strong\u003e\u003cbr\u003eModuł obsługuje cztery kanały monitorujące.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy moduł może współpracować z 2-przewodowymi przetwornikami ciśnienia?\u003c\/strong\u003e\u003cbr\u003eTak. Obsługuje przetworniki 2-przewodowe i 3-przewodowe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo to jest tryb kaskadowy w monitorze?\u003c\/strong\u003e\u003cbr\u003eTryb kaskadowy rozprowadza jeden sygnał wejściowy przetwornika na wszystkie cztery kanały.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy moduł zapewnia wyjścia analogowe?\u003c\/strong\u003e\u003cbr\u003eTak. Każdy kanał ma wyjście rejestratora +4 do +20 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie opcje filtracji są dostępne?\u003c\/strong\u003e\u003cbr\u003eMonitor obsługuje konfigurowalne filtry pasmowe i zaporowe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy filtr zaporowy może działać zarówno na 50 Hz, jak i 60 Hz?\u003c\/strong\u003e\u003cbr\u003eTak. Obsługiwane są oba wybory częstotliwości sieciowej.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo wskazuje dioda LED TX\/RX?\u003c\/strong\u003e\u003cbr\u003eWskazuje aktywność komunikacji z innymi modułami w szafie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak konfiguruje się progi alarmowe?\u003c\/strong\u003e\u003cbr\u003ePoziomy alarmów konfiguruje się za pomocą oprogramowania 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest cel buforowanych wyjść przetworników?\u003c\/strong\u003e\u003cbr\u003eZapewniają bezpośredni dostęp do sygnału dla zewnętrznej analizy i diagnostyki.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaki system szaf jest wymagany do instalacji?\u003c\/strong\u003e\u003cbr\u003eModuł działa w ramach szaf Bently Nevada serii 3500.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eW jakich branżach najczęściej używa się tego modułu?\u003c\/strong\u003e\u003cbr\u003ePrzemysł naftowy i gazowy, energetyka, petrochemia oraz zakłady przetwórstwa przemysłowego.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy monitor obsługuje funkcje ochrony maszyn?\u003c\/strong\u003e\u003cbr\u003eTak. Ciągle porównuje zmierzone wartości z skonfigurowanymi progami alarmowymi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo wskazuje dioda LED Bypass?\u003c\/strong\u003e\u003cbr\u003eWskazuje, że moduł działa w trybie obejścia.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517291371,"sku":"3500\/64M 176449-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-64m-176449-05-dynamic-pressure-monitor-module-kive35tlllm_f98dd0a7-4b94-4118-91c0-9e7b514ac8cc.jpg?v=1765440104"},{"product_id":"bently-nevada-140734-02-3500-42m-proximitor®-seismic-monitor","title":"Bently Nevada 140734-02 3500\/42M Proximitor®\/Monitor sejsmiczny","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/42M\u003c\/strong\u003e, oznaczony jako zespół części zamiennych \u003cstrong\u003e140734-02\u003c\/strong\u003e, jest czterokanałowym urządzeniem ochrony maszyn zaprojektowanym do przetwarzania sygnałów z przetworników zbliżeniowych i sejsmicznych. Moduł działa jako warstwa analityczna bezpieczeństwa w systemie ochrony maszyn 3500, przetwarzając analogowe sygnały falowe w celu obliczania zmiennych takich jak drgania promieniowe, pozycja osiowa, ekscentryczność lub prędkość oraz wykonując porównania z programowalnymi przez użytkownika progami alarmowymi. Programowany w parach kanałów za pomocą oprogramowania 3500 Rack Configuration Software, uruchamia automatyczne alarmy po przekroczeniu ustawionych limitów bezpieczeństwa. Sprzęt dostarcza indywidualne pętle prądowe +4 do +20 mA dla każdego kanału, aby przesyłać w czasie rzeczywistym wartości statyczne bezpośrednio do rozproszonych sieci sterowania i serwerów archiwizacji operacyjnej bez przerywania podstawowych operacji ochronnych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCztery niezależne kanały przetwarzania obsługujące wiele jednoczesnych typów funkcji drgań i położenia.\u003c\/li\u003e\n\u003cli\u003eElastyczne dopasowanie przetworników obsługujące standardowe sondy indukcyjne, akcelerometry i czujniki prędkości.\u003c\/li\u003e\n\u003cli\u003eArchitektury programowania kanałów parami umożliwiające różne operacje matematyczne na parach kanałów 1-2 i 3-4.\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne przypisanie progów alarmowych i niebezpieczeństwa wspierające szczegółowe limity bezpieczeństwa maszyn dla wszystkich obliczanych wartości statycznych.\u003c\/li\u003e\n\u003cli\u003eIndywidualne, przednie połączenia koncentryczne buforowanych przetworników zaprojektowane z ochroną przed zwarciem do diagnostyki strukturalnej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eŚledzenie drgań promieniowych wału wirnika przemysłowej turbiny parowej oraz obserwacja pozycji osiowej.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie prędkości sejsmicznej obudowy dużych sprężarek gazowych odśrodkowych oraz ochrona mechaniczna przed awarią.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie drgań absolutnych wału turbiny gazowej do wytwarzania energii oraz ekscentryczności wirnika.\u003c\/li\u003e\n\u003cli\u003eAnaliza stanu łożysk tocznych pomp przemysłowych cieczy ciężkich za pomocą specjalistycznej logiki REBAM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/42-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor sejsmiczny Proximitor®\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Typ modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Seismic z zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Seismic z zakończeniami zewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O TMR Prox\/Seismic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi (4 kanały prox.\/akcelerometru) i zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi (2 kanały prox.\/akcelerometru + 2 kanały Velomitor®) i zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi (4 kanały Velomitor®) i zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O wału absolutnego z zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O wału absolutnego z zakończeniami zewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e09\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Velom z zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Velom z zakończeniami zewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Opcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C (Klasa 1, Podział 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX\/CSA (Klasa 1, Strefa 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęści zamienne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e140734-02\u003c\/td\u003e\n\u003ctd\u003eMonitor Proximitor®\/Seismic 3500\/42M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140734-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWejścia sygnałowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAkceptuje 1 do 4 sygnałów z przetworników zbliżeniowych, prędkości lub przyspieszenia \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandardowa impedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ dla wejść Proximitor i przyspieszenia \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa magistrali TMR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEfektywna impedancja 50 kΩ przy 3 kanałach połączonych równolegle \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne zużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 7,7 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWskaźniki stanu na panelu przednim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDioda LED OK, dioda LED TX\/RX, dioda LED obejścia \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorty wyjścia buforowanego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 koaksjalne złącza chronione przed zwarciem (1 na kanał) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wyjścia buforowanego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZasilanie przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjście prądowe rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 do +20 mA DC indywidualna pętla na kanał \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNapięcie zgodności rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZakres napięcia rejestratora 0 do +12 V DC na obciążeniu \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres rezystancji obciążenia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do 600 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRozdzielczość bitowa analogowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,3662 µA na bit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęstotliwość aktualizacji danych\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms lub mniej \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiltr rozszerzenia siły\/różnicowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiltr bezpośredni: -3 dB przy 1,2 Hz | Filtr szczelinowy: -3 dB przy 0,41 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność wartości statycznej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo w granicach ±0,33% pełnej skali, maksymalnie ±1% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność nastawy alarmu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach 0,13% wartości docelowej \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres opóźnienia alarmu ostrzegawczego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund w odstępach co 1 sekundę \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres opóźnienia alarmu niebezpieczeństwa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,1 sekundy lub 1 do 60 sekund w odstępach co 0,5 sekundy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (I\/O standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 stopni Celsjusza do +65 stopni Celsjusza (-22 do +150 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (I\/O z barierą)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 stopni Celsjusza do +65 stopni Celsjusza (32 do 150 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 stopni Celsjusza do +85 stopni Celsjusza (-40 do +185 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wilgotności pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% wilgotności względnej bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu monitorującego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg (2,0 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O (bez bariery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,20 kg (0,44 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O (bariera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu monitorującego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 91,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O (bariera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary zajmowane w szafie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowysokościowy slot przedni i 1 pełnowysokościowy slot tylny \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Pin złącza\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKoaksjalne złącza na panelu przednim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuforowane wyjście chronione przed zwarciem do diagnostyki sygnału dynamicznego \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminale I\/O Prox\/Seismic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTylne bloki przewodów interfejsu do bezpośredniego wewnętrznego podłączenia czujników \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZewnętrzne złącza zakończeniowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane wielopinowe złącza współpracujące z samodzielnymi blokami zaciskowymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjścia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane punkty połączeń pętli dla proporcjonalnej telemetrii +4 do +20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTłumienie szumów: Zapewnij dokładne utrzymanie parametrów ekranowania czujnika poprzez połączenie przewodów uziemiających przyrządów z określonymi punktami uziemienia obudowy na bloku I\/O, aby ograniczyć sprzężenie elektromagnetyczne.\u003c\/li\u003e\n\u003cli\u003eMapowanie wyrównania: Potwierdź, że główny zespół karty \u003cstrong\u003e140734-02\u003c\/strong\u003e ślizga się gładko po prowadnicach przedniego slotu szafy, mocno osadzając się w tylnych liniach magistrali danych.\u003c\/li\u003e\n\u003cli\u003eZasady zakończeń: Nigdy nie łącz zewnętrznych bloków zakończeniowych z modułami I\/O zaprojektowanymi i oznaczonymi do zastosowań wewnętrznego zakończenia.\u003c\/li\u003e\n\u003cli\u003ePrzydział miejsca: Zachowaj wolne linie przepływu powietrza na przednich i tylnych krawędziach ramy szafy, aby zapewnić niezakłócony przepływ powietrza przez obudowy modułów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDyrektywy niskonapięciowe CE: Wymagania bezpieczeństwa EN61010-01 dla przemysłowego sprzętu monitorującego.\u003c\/li\u003e\n\u003cli\u003eEkranowanie emisji EMC: Certyfikowane zgodnie z IEC\/EN 61000-6-4 oraz normą EN 55011 Klasa A.\u003c\/li\u003e\n\u003cli\u003eKryteria odporności EMC: Spełnia normy EN 61000-4-2 wyładowania elektrostatycznego (kryterium B) oraz EN 61000-4-3 odporności na promieniowanie (kryterium A).\u003c\/li\u003e\n\u003cli\u003eZatwierdzenia do stref zagrożonych wybuchem: CSA\/NRTL\/C Klasa I, Podział 2, Grupy A, B, C, D (klasa T4 przy Ta = -30°C do +65°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne i dotyczące zaopatrzenia\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy ten komponent może działać jako mechanizm absolutnego wyłączania maszyny przy nadmiernej prędkości?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Nie, to urządzenie jest specjalnie zaprojektowane do obsługi dynamicznych pomiarów proximitorów oraz przyspieszenia\/prędkości sejsmicznej, a nie do wyzwalaczy krawędzi koła prędkości o wysokiej częstotliwości potrzebnych do deterministycznych pętli ochrony przed nadmierną prędkością.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jaka jest podstawowa różnica między oznaczeniem 3500\/42M a numerem części 140734-02?\u003c\/strong\u003e O: 3500\/42M to oficjalna klasyfikacja serii monitorów systemowych, natomiast kod 140734-02 to dokładny numer katalogowy zamówienia na wewnętrzną płytę główną do wymiany.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy nieoczekiwane zwarcie w pętli rejestratora prądu +4 do +20 mA zakłóci ochronę maszyn?\u003c\/strong\u003e O: Nie, obwód analogowej pętli prądowej jest wewnętrznie izolowany, co oznacza, że logika przetwarzania, funkcje monitorujące i alarmy bezpieczeństwa działają normalnie, nawet jeśli pętla rejestratora ulegnie zwarciu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy można zaprogramować kanał 1 do obliczania drgań promieniowych, podczas gdy kanał 2 ocenia pozycję osiową?\u003c\/strong\u003e O: Nie, kanały monitorujące są konfigurowane programowo w odrębnych parach funkcjonalnych, co oznacza, że kanały 1 i 2 muszą wykonywać tę samą podstawową funkcję, podczas gdy kanały 3 i 4 mogą obsługiwać inną.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Co się dzieje z wskaźnikami na przednim panelu, jeśli moduł napotka wewnętrzny błąd przetwarzania?\u003c\/strong\u003e O: Zielona dioda OK przestanie świecić ciągłym światłem, sygnalizując wystąpienie wyjątku sprzętowego i inicjując bezpieczny stan obejścia systemu, aby uniknąć fałszywych wyłączeń z powodu przekroczenia limitu.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517717355,"sku":"3500\/42M 140734-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42m-140734-02-proximitor-seismic-monitor-pwa-r0numhbecec_3ab792c9-f156-41de-b90f-53ed4538fa1b.jpg?v=1765440108"},{"product_id":"bently-nevada-176449-03-3500-44m-aeroderivitive-gt-vibration-monitor","title":"Monitor drgań Bently Nevada 176449-03 3500\/44M Aeroderivative GT","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/44M\u003c\/strong\u003e, pełny numer zestawu części zamiennych \u003cstrong\u003e176449-03\u003c\/strong\u003e, jest czterokanałowym instrumentem sprzętowym maszyn specjalnie zaprojektowanym do przetwarzania drgań turbin gazowych aeroderiwatywnych. Moduł działa jako dedykowany podsystem techniczny w ramach Systemu Ochrony Maszyn 3500, pozyskując sygnały bezpośrednio z czujników prędkości Velomitor oraz dynamicznych akcelerometrów za pośrednictwem specjalistycznego zewnętrznego sprzętu interfejsowego. Nieustannie wykonuje algorytmiczne porównania wskaźników stanu maszyny w czasie rzeczywistym z programowalnymi przez użytkownika limitami alarmowymi, aby sterować lokalnymi przekaźnikami ochronnymi. Korzystając z Oprogramowania Konfiguracji Szafy 3500, komponent obsługuje logikę wielomodalną z możliwością obsługi do ośmiu indywidualnych profili limitów alarmów i zagrożeń na kanał, dostosowując się natychmiast do aktywnych stanów obciążenia silnika za pomocą sprzętowych wejść kontaktowych lub magistrali komunikacyjnej. Zintegrowane filtry śledzące sygnał akceptują podwójne niezależne odniesienia Keyphasor, zapewniając dokładne synchroniczne śledzenie amplitudy 1X oraz szerokopasmowe śledzenie pasma na wałach turbiny o zmiennej prędkości.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCztery kanały wejściowe zoptymalizowane do niskoszumowego, wysokoczęstotliwościowego śledzenia drgań obudowy turbiny gazowej aeroderiwatywnej.\u003c\/li\u003e\n\u003cli\u003ePodwójne przypisanie wejścia Keyphasor umożliwiające oddzielne opcje filtrów śledzących dla każdej pary kanałów.\u003c\/li\u003e\n\u003cli\u003eFunkcjonalność kanałów wielomodalnych przechowująca do ośmiu odrębnych zestawów macierzy alarmów, zagrożeń i opóźnień czasowych.\u003c\/li\u003e\n\u003cli\u003eWewnętrzna logika integracji sygnału przekształcająca surowe wartości przyspieszenia na metryki prędkości bez użycia zewnętrznego sprzętu.\u003c\/li\u003e\n\u003cli\u003ePrzednie współosiowe wyjścia buforowane umożliwiające nieprzetworzone przechwytywanie sygnału czujnika za pomocą analizatorów diagnostycznych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eŚledzenie drgań obudowy pakietu napędowego generatora turbin gazowych aeroderiwatywnych pochodzenia lotniczego.\u003c\/li\u003e\n\u003cli\u003eWysokoprędkościowe monitorowanie drgań wirnika turbiny napędu mechanicznego przemysłowego oraz synchronizacja śledzenia wału 1X.\u003c\/li\u003e\n\u003cli\u003eWielomodalna ochrona awaryjnego wyłączania stacji sprężarek gazociągu przesyłowego.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie szybkiego startu turbiny gazowej elektrowni o szczytowym obciążeniu oraz dynamiczna adaptacja trybu pracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/44M-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor drgań turbin gazowych aeroderiwatywnych GT\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Typ modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Aero GT z zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Aero GT z zakończeniami zewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Velom z zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Velom z zakończeniami zewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Velom wielomodowy z zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Velom wielomodowy z zakończeniami zewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Opcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C (Klasa 1, Podział 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX\/IECEx\/CSA (Klasa 1, Strefa 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęści zamienne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e176449-03\u003c\/td\u003e\n\u003ctd\u003eGłówny moduł monitora drgań 3500\/44M Aeroderivitive GT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/44M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e176449-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLiczba kanałów wejściowych\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kanały\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypy sygnałów wejściowych\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAkcelerometry, czujniki Velomitor, sondy zbliżeniowe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne zużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 7,7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa (standardowa)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ (typ I\/O Prox\/Velom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność integracji sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo w granicach ±0,33% pełnej skali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres śledzenia drgań 1X\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,0 Hz do 4000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres częstotliwości pasma przepustowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardowa konfiguracja 10 Hz do 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuforowane wyjścia przetworników\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKoaksjalne złącza BNC na panelu przednim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuforowana impedancja wyjściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterwały opóźnienia alarmu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKonfigurowalny od 0,1 do 60 sekund\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 stopni Celsjusza do +65 stopni Celsjusza (-22 stopni Fahrenheita do +150 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 stopni Celsjusza do +85 stopni Celsjusza (-40 stopni Fahrenheita do +185 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wilgotności pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% wilgotności względnej bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga głównej karty monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu zaciskowego I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary głównego monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,2 mm x 24,4 mm x 99,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania dotyczące przestrzeni w obudowie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowysokie przednie gniazdo i 1 pełnowysokie tylne gniazdo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMinimalizacja szumów: prowadzić pary sygnałowe Velomitor lub akcelerometru przez ekranowane skręcone przewody, zaciskając miedzianą osłonę uziemienia tylko w tylnych punktach wspólnej obudowy karty I\/O.\u003c\/li\u003e\n\u003cli\u003ePozycjonowanie modułu: wsunąć główny zespół karty \u003cstrong\u003e176449-03\u003c\/strong\u003e do przedniego gniazda kosza obudowy 3500, bezpośrednio naprzeciwko odpowiadającego mu tylnego bloku interfejsu zakończeń.\u003c\/li\u003e\n\u003cli\u003eZakończenia pinów trybu: podczas korzystania z profili funkcji wielomodowych należy zapewnić, aby zewnętrzne styki przełączające były podłączone za pomocą suchych, beznapięciowych pętli do wyznaczonego bloku zacisków I\/O.\u003c\/li\u003e\n\u003cli\u003eOchrona termiczna: Upewnij się, że wentylatory obudowy pozostają niezakłócone, aby uniknąć gorących punktów w instalacjach monitorów czterokanałowych o wysokiej gęstości.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDyrektywa niskonapięciowa: EN 61010-1 wymagania elektryczne i bezpieczeństwa dla sprzętu śledzącego.\u003c\/li\u003e\n\u003cli\u003eKompatybilność elektromagnetyczna: normy EN 61000-6-2 odporność przemysłowa i EN 61000-6-4 emisje przemysłowe.\u003c\/li\u003e\n\u003cli\u003eZatwierdzenia do stref zagrożonych wybuchem: klasyfikacja CSA Klasa I, Dywizja 2, grupy A, B, C i D zgodnie z kodem opcji 01.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne i zakupowe\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Czy ten komponent może bezpośrednio współpracować z czujnikami przyspieszenia wysokotemperaturowego bez dodatkowego sprzętu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Nie, standardowe akcelerometry lub sondy obudowy wysokotemperaturowej wymagają dopasowanych zewnętrznych wzmacniaczy ładunku lub zewnętrznych podmodułów interfejsu, zanim zaciski zostaną podłączone do monitora.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Jaka jest fizyczna różnica konstrukcyjna między modelem 3500\/44M a komponentem 176449-03?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: 3500\/44M definiuje pełny katalog produktów monitoringu aeroderiwatywnego, natomiast 176449-03 określa numer części zamiennej do bezpośredniej wymiany w magazynie dla samej głównej karty przetwarzającej.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Jak działa wewnętrzna architektura śledzenia wielomodalnego podczas zmiany obciążenia turbiny?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Monitor próbuje statusy zewnętrznych suchych styków lub słów sieciowych oprogramowania, dopasowując się do aktualnego etapu pracy turbiny, aby natychmiast przejść do jednego z ośmiu oddzielnych, zdefiniowanych przez użytkownika zestawów alarmów ostrzegawczych i niebezpieczeństwa.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Czy możliwe jest skonfigurowanie tego urządzenia bez dedykowanej karty odniesienia pętli prędkości Keyphasor w racku?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Tak, podstawowe operacje szerokopasmowego filtrowania mogą działać niezależnie, ale synchroniczne śledzenie wału 1X wymaga aktywnych sygnałów odniesienia Keyphasor dostarczanych przez wewnętrzną szynę racka.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Czy usterka linii pomiarowej na jednym przetworniku wpłynie na wydajność analizy danych pozostałych trzech kanałów?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Nie, indywidualne ścieżki przetwarzania wewnątrz modułu izolują uszkodzone linie pomiarowe, więc aktywna usterka na kanale 1 spowoduje wyłączenie jego konkretnej diody LED OK bez zakłócania pomiarów sąsiednich kanałów.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517782891,"sku":"3500\/44M 176449-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-44m-176449-03-vibration-monitor-s53vd2uwauz_7c4df997-9084-4cff-82ad-f52739bb4f25.jpg?v=1765440109"},{"product_id":"bently-nevada-3500-53m-286566-01-overspeed-detection-module","title":"Moduł wykrywania przekroczenia prędkości Bently Nevada 3500\/53M 286566-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e3500\/53M\u003c\/strong\u003e (Numer wewnętrznej płytki obwodu: \u003cstrong\u003e286566-01\u003c\/strong\u003e) to wysokiej integralności komponent sprzętowy zaprojektowany dla matrycy ochrony maszyn \u003cstrong\u003eAC 3500\u003c\/strong\u003e, zapewniający ciągłe, bardzo niezawodne \u003cstrong\u003eelektroniczne wykrywanie przekroczenia prędkości\u003c\/strong\u003e. Ten moduł przetwarzający odczytuje w czasie rzeczywistym przebiegi częstotliwości z sond zbliżeniowych lub magnetycznych czujników prędkości, aby ocenić prędkość obrotową z ekstremalną dokładnością. Architektura \u003cstrong\u003e3500\/53M 286566-01\u003c\/strong\u003e wykonuje pętle obliczeniowe na poziomie mikrosekund, aby identyfikować destrukcyjne anomalie przekroczenia i niedoboru prędkości na krytycznych wirujących elementach.\u003c\/p\u003e\n\u003cp\u003eZaprojektowany zgodnie z rygorystycznymi normami bezpieczeństwa maszyn API 670 i API 612, ten moduł działa jako autonomiczny węzeł głosujący w szafie sterowniczej. Funkcjonuje w redundantnych topologiach sieciowych (takich jak bloki głosowania 2 z 2 lub 2 z 3), aby wykonywać automatyczne sygnały awaryjnego wyłączenia, chroniąc sprzęt kapitałowy bez konieczności interwencji zewnętrznego oprogramowania nadrzędnego. Zespół modułu półprzewodnikowego posiada zintegrowane kanały interfejsu do przesyłania surowych danych fazowych bezpośrednio do lokalnych kart logiki oraz zdalnych sieci maszyn.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eParametry przetwarzania sygnału na poziomie mikrosekund zapewniające natychmiastową, bardzo dokładną weryfikację przekroczenia prędkości.\u003c\/li\u003e\n\u003cli\u003eBezpośrednia kompatybilność z tablicami przetworników zbliżeniowych oraz pasywnymi lub aktywnymi elementami pomiaru prędkości magnetycznej.\u003c\/li\u003e\n\u003cli\u003eZaprojketowany do integracji złożonej logiki głosowania w celu eliminacji fałszywych wyłączeń maszyn w polach produkcyjnych.\u003c\/li\u003e\n\u003cli\u003eWbudowany zestaw diod LED diagnostycznych na przednim panelu umożliwiający natychmiastowe śledzenie stanu modułu.\u003c\/li\u003e\n\u003cli\u003eWewnętrzna architektura płyty drukowanej w technologii półprzewodnikowej zapewniająca wysoką stabilność strukturalną wobec cyklicznych drgań panelu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNatychmiastowa ochrona przed przekroczeniem prędkości i rejestrowanie awaryjnych wyłączeń na turbinach parowych i gazowych zakładów użyteczności publicznej.\u003c\/li\u003e\n\u003cli\u003eCiągły monitoring prędkości obrotowej i indeksowanie fazy odniesienia w dużych przemysłowych sprężarkach procesowych.\u003c\/li\u003e\n\u003cli\u003eWysokozawodne pętle bezpieczeństwa maszyn na krytycznych generatorach energii i turbinach rozprężnych wysokociśnieniowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReferencja zamówienia produktu\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGłówne oznaczenie modelu systemu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/53M (Moduł elektronicznego wykrywania przekroczenia prędkości)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWewnętrzny kod części sprzętowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e286566-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp konfiguracji modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardowy ulepszony zespół przetwarzania przekroczenia prędkości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/53M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWewnętrzne odniesienie płyty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e286566-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł elektronicznego wykrywania przekroczenia prędkości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKanały wejścia sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObsługa wielokanałowych wejść czujników prędkości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKompatybilność przetworników\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCzujniki zbliżeniowe, magnetyczne odbiorniki (MUP) lub aktywne czujniki prędkości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTopologie logiki głosowania systemu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObsługuje architektury głosowania 2 z 2 lub 2 z 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit czasu reakcji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWykonanie w zakresie mikrosekund dla krytycznej logiki wyłącznika\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfil interfejsu systemowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardowa tablica złączy tylnej płyty dla szaf serii 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZgodność ze standardami\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZaprojektowany zgodnie z kryteriami wydajności API 670 i API 612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObudowa mechaniczna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNiskoprofilowa architektura modułu wtykowego z zintegrowaną płytką czołową\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatur pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardowa obudowa o wysokiej wydajności przeznaczona do środowisk szaf o dużej gęstości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReferencja wagi operacyjnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWaga modułu szafy serii 3500 zgodna ze standardami przemysłowymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWarstwa portu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGniazdo na przedniej płycie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDynamiczny port koncentryczny do lokalnej weryfikacji przebiegu prędkości i narzędzi testowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTablica złączy tylnej płyty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzypisania pinów dla dystrybucji zasilania, wejść czujników i głównych połączeń magistrali logicznej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWkładanie do gniazda szafy:\u003c\/strong\u003e Wsuń moduł mocno wzdłuż plastikowych prowadnic ramy szafy 3500, aż osadzi się w złączach tylnej płyty. Dokładnie dokręć śruby motylkowe na przedniej płycie, aby go zablokować.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEkranowanie przewodów czujnika:\u003c\/strong\u003e Prowadź wszystkie przewody wejściowe czujnika prędkości przez oddzielne, dedykowane przewody przyrządowe. Utrzymuj te linie niskonapięciowe izolowane od równoległych linii silnika o wysokiej mocy, aby zmniejszyć zakłócenia EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowiązanie konfiguracji głosowania:\u003c\/strong\u003e Sprawdź wszystkie sprzętowe zwory i parametry głosowania w oprogramowaniu w panelu konfiguracyjnym 3500 przed aktywacją automatycznych wyjść awaryjnego wyłącznika.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eŚrodek ostrożności elektrostatycznej:\u003c\/strong\u003e Zawsze używaj uziemionego paska na nadgarstek podczas obsługi tablicy obwodów 286566-01, aby chronić wrażliwe komponenty CMOS przed uszkodzeniami spowodowanymi wyładowaniami elektrostatycznymi.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518765931,"sku":"3500\/53M 286566-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-54m-286566-01-overspeed-detection-module-c322kgbugst_758ffe52-8949-45c8-8e05-39ce67670a71.jpg?v=1765440120"},{"product_id":"bently-nevada-133819-02-3500-61-rtd-tc-non-isolated-i-o-module","title":"Moduł Wejścia\/Wyjścia Nieizolowany Bently Nevada 133819-02 3500\/61 RTD\/TC","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBently Nevada \u003cstrong\u003e133819-02\u003c\/strong\u003e\u003c\/span\u003e to specjalistyczny \u003cspan\u003emoduł RTD\/TC bez izolacji I\/O\u003c\/span\u003e zaprojektowany dla \u003cstrong\u003emonitoru temperatury 3500\/61.\u003c\/strong\u003e Moduł ten zapewnia fizyczny interfejs dla sześciu kanałów monitorowania temperatury, obsługując zarówno detektory temperatury rezystancyjnej (RTD), jak i termopary (TC). \u003cspan\u003e133819-02\u003c\/span\u003e posiada \u003cspan\u003ewewnętrzne zaciski\u003c\/span\u003e, umożliwiające podłączenie okablowania bezpośrednio do bloków zaciskowych na samym module I\/O. Ta wersja bez izolacji oferuje maksymalną elastyczność, pozwalając użytkownikom na konfigurację modułu dla TC, RTD lub mieszanki obu typów czujników na sześciu kanałach.\u003c\/p\u003e\n\u003ch3\u003eFunkcjonalna inteligencja i wyjścia rejestratora\u003c\/h3\u003e\n\u003cp\u003eJako komponent serii \u003cspan\u003e3500\/61\u003c\/span\u003e, ten moduł I\/O zawiera dedykowane \u003cspan\u003ewyjścia rejestratora\u003c\/span\u003e dla każdego z sześciu kanałów. Dostarcza sygnał \u003cspan\u003e+4 do +20 mA\u003c\/span\u003e proporcjonalny do pełnej skali monitora, umożliwiając płynną integrację z zewnętrznymi systemami sterowania, DCS lub rejestratorami wykresowymi do zapisu danych. Architektura modułu jest odporna na awarie; działanie monitora nie jest zakłócane przez zwarcia na wyjściach rejestratora, co zapewnia ciągłość podstawowych funkcji ochrony maszyn.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eAtrybut\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSzczegóły specyfikacji\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumer części\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e133819-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKompatybilność monitora\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/61\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKanały wejściowe\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 (programowalne indywidualnie dla RTD lub TC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTyp zakończenia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWewnętrzne zaciski (na module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIzolacja\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBez izolacji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eŹródło prądu RTD\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 15 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA @ 25 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWyjście rejestratora\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+4 do +20 mA (obciążenie: 0 do 600 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΩ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDokładność (wewnętrzna)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 3 °C @ 25 °C (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 5,4 °F @ 77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperatura pracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C do +65 °C (-22 °F do +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWaga\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,45 kg (1,0 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWymiary (WxSxG)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 99,1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eJaka jest główna różnica między modułami 3500\/60 a 3500\/61?\u003c\/span\u003eOba moduły oferują identyczną funkcjonalność monitorowania temperatury na sześciu kanałach. Jednak \u003cspan\u003e3500\/61\u003c\/span\u003e (używający modułu I\/O \u003cspan\u003e133819-02\u003c\/span\u003e) posiada wyjścia rejestratora 4-20 mA dla każdego kanału, podczas gdy 3500\/60 nie oferuje tych wyjść analogowych.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCzy mogę mieszać różne typy czujników na jednym module 133819-02?\u003c\/span\u003eTak. W przeciwieństwie do wersji izolowanych, ten moduł I\/O bez izolacji może być skonfigurowany za pomocą \u003cspan\u003eoprogramowania konfiguracyjnego 3500 Rack\u003c\/span\u003e, aby akceptować dowolną kombinację wejść TC i RTD na sześciu kanałach.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJak moduł obsługuje okablowanie RTD?\u003c\/span\u003eModuł dostarcza specjalistyczne źródło prądu o wartości \u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA\u003c\/span\u003e. Jest zaprojektowany do obsługi RTD 3-przewodowych (używając dwóch źródeł prądu do kompensacji przewodów) oraz RTD 4-przewodowych (używając pojedynczego źródła), co zapewnia dokładny pomiar temperatury dla różnych typów przetworników.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik inżynieryjny i instalacyjny\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eZarządzanie wewnętrznymi zaciskami:\u003c\/span\u003e \u003cspan\u003e133819-02\u003c\/span\u003e wykorzystuje wewnętrzne bloki zaciskowe. Upewnij się, że okablowanie polowe jest odpowiednio oznakowane i solidnie przymocowane, aby zapobiec przerywanym sygnałom, które mogłyby wywołać diody LED statusu „Bypass” lub „Error” na przednim panelu monitora.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarunki środowiskowe:\u003c\/span\u003e Moduł jest przystosowany do pracy w zakresie temperatur od \u003cspan\u003e-30 °C do +65 °C\u003c\/span\u003e. W przypadku instalacji w ekstremalnych warunkach zapewnij odpowiednią wentylację szafy 3500, aby utrzymać te limity i zapobiec dryfowi dokładności.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKonfiguracja TMR:\u003c\/span\u003e W zastosowaniach z potrójną modularną redundancją (TMR) należy zainstalować trzy monitory temperatury w sąsiednich grupach. System stosuje dwa typy głosowania, aby zapobiec fałszywym alarmom spowodowanym pojedynczymi awariami w krytycznych maszynach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZalety inżynieryjne\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBently Nevada 133819-02\u003c\/span\u003e oferuje ekonomiczne, wysokogęstościowe rozwiązanie do ochrony temperatury maszyn. Łącząc obsługę TC i RTD w jednym module z wewnętrznymi zaciskami, zmniejsza zajmowaną przestrzeń w szafie i upraszcza okablowanie. Przy zakupach B2B wybór oryginalnego \u003cspan\u003e133819-02\u003c\/span\u003e gwarantuje pełną kompatybilność z \u003cspan\u003esystemem monitoringu 3500\u003c\/span\u003e, zachowując wysoką dokładność i wytrzymałość niezbędną do ochrony turbin, sprężarek i dużych silników przemysłowych.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518864235,"sku":"133819-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133819-02-rtd-tc-temp-i-o-module-olhm4jqsb0w_ea2a25c8-3e12-4f5e-a5c2-4a168d80f750.jpg?v=1765440121"},{"product_id":"bently-nevada-3500-15-127610-01-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15 127610-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł zasilania \u003cstrong\u003eBently Nevada 3500\/15\u003c\/strong\u003e to moduł o wysokiej dostępności, zaprojektowany do niezawodnego i regulowanego zasilania systemu monitorującego 3500. Instalowany w najbardziej lewych slotach szafy 3500, \u003cstrong\u003e127610-01\u003c\/strong\u003e akceptuje szeroki zakres napięć wejściowych AC i przetwarza je na niezbędne napięcia DC wymagane przez inne moduły w tej samej szafie. \u003cstrong\u003e3500\/15\u003c\/strong\u003e obsługuje konfiguracje redundantne, pozwalając na jednoczesną instalację dwóch modułów w jednej szafie, aby zapewnić nieprzerwaną pracę krytycznych systemów monitorowania drgań i ochrony maszyn w środowiskach przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObsługuje konfiguracje redundantne zasilania, aby zapobiec przestojom systemu.\u003c\/li\u003e\n\u003cli\u003eKompatybilny ze standardowymi szafami monitorującymi serii 3500.\u003c\/li\u003e\n\u003cli\u003eUtrzymuje stałe dostarczanie mocy przy zmiennych częstotliwościach wejściowych.\u003c\/li\u003e\n\u003cli\u003eZaprojketowany do pracy w trudnych warunkach przemysłowych z rozszerzonym zakresem temperatur pracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystemy ochrony maszyn (TSI)\u003c\/li\u003e\n\u003cli\u003eCiągły monitoring drgań\u003c\/li\u003e\n\u003cli\u003eZasoby przemysłu naftowego i gazowego, energetycznego oraz petrochemicznego\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 35.443%;\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 64.135%;\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eNumer części \/ model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e3500\/15 (127610-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eModuł zasilania AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eLegacy wysokie napięcie AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eNominalne napięcie wejściowe AC wysokiego napięcia Legacy 220 Vac (175 do 264 Vac rms, 247 do 373 Vac pk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eLegacy niskie napięcie AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eNominalne napięcie wejściowe AC niskiego napięcia Legacy 110 Vac (85 do 132 Vac rms, 120 do 188 Vac pk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eUniwersalne napięcie wejściowe AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eNominalne napięcie wejściowe AC 110 do 220 Vac (85 do 264 Vac rms, 120 do 373 Vac pk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eZakres częstotliwości wejściowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e47 do 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e-30 do +65 stopni Celsjusza (-22 do +150 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e-40 do +85 stopni Celsjusza (-40 do +185 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e1,39 kg (3,06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmiejscowienie w slocie:\u003c\/strong\u003e Instaluj moduł zasilania tylko w dedykowanych slotach zasilania po lewej stronie szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKompatybilność modułów:\u003c\/strong\u003e Upewnij się, że moduł zasilania AC i tylny moduł wejścia zasilania (PIM) mają zgodny typ konfiguracji (Universal vs. Legacy) przed podłączeniem zasilania. Moduły Universal nie są kompatybilne z jednostkami Legacy o wysokim lub niskim napięciu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja redundancji:\u003c\/strong\u003e Przy użyciu dwóch modułów zasilania do redundancji, podłącz każde zasilanie do oddzielnego, niezależnego źródła zasilania, aby zmaksymalizować niezawodność systemu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChłodzenie i wentylacja:\u003c\/strong\u003e Zachowaj odpowiedni odstęp wokół obudowy szafy, aby spełnić określone limity temperatury otoczenia podczas pracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518962539,"sku":"3500\/15 127610-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-127610-01-power-supply-module-horgjmyfeju_4270d19c-b1f7-473d-96b3-908e4ec414e9.jpg?v=1765440124"},{"product_id":"bently-nevada-129486-01-3500-15-legacy-high-voltage-dc-power-supply-module","title":"Moduł zasilania wysokiego napięcia prądu stałego Bently Nevada 129486-01 3500\/15 Legacy","description":"\u003cp\u003eModuł \u003cstrong\u003e129486-01\u003c\/strong\u003e to \u003cstrong\u003emoduł zasilania stałym napięciem wysokiego napięcia 3500\/15 Legacy\u003c\/strong\u003e zaprojektowany do dostarczania regulowanego zasilania do pełnej szafy systemu ochrony maszyn serii 3500. Ten moduł o połowie wysokości akceptuje wejście wysokiego napięcia stałego i przekształca je na precyzyjnie regulowane poziomy odpowiednie do pracy innych zintegrowanych modułów monitorujących 3500. Szafa systemu 3500 mieści do dwóch zasilaczy jednocześnie po lewej stronie, tworząc w pełni redundantną architekturę zasilania, gdzie moduł w dolnym slocie pełni funkcję zasilacza podstawowego, a moduł w górnym slocie działa jako zasilacz zapasowy. Wkładanie lub wyjmowanie dowolnego modułu zasilania może być wykonywane podczas pracy na żywo bez zakłócania funkcji systemu szafy, pod warunkiem, że drugi źródło zasilania pozostaje aktywne.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWsparcie pracy redundantnej\u003c\/strong\u003e: Pozwala na jednoczesne zainstalowanie dwóch jednostek w jednej ramie szafy, tworząc zautomatyzowany układ bezpieczeństwa zasilania podstawowego i zapasowego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMożliwość wymiany na gorąco\u003c\/strong\u003e: Umożliwia bezpieczne usuwanie lub wkładanie pojedynczych modułów bez przerywania działania ochrony maszyn.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZintegrowane zabezpieczenia bezpieczeństwa\u003c\/strong\u003e: Wyposażony w wbudowaną ochronę przed przepięciem, która inicjuje stan przerwania bezpiecznika na module zasilania, zabezpieczając elektronikę wewnętrzną.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWskaźnik diagnostyczny stanu\u003c\/strong\u003e: Panel przedni zawiera dedykowaną zieloną diodę LED \"SUPPLY OK\", zapewniającą natychmiastowe wizualne potwierdzenie prawidłowego działania modułu zasilania.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstalacje zapasowej infrastruktury zasilania wysokim napięciem stałym dla ochrony krytycznych maszyn obrotowych.\u003c\/li\u003e\n\u003cli\u003eZapasowa wymiana modułu zasilania w szafach monitorujących turbiny parowe i gazowe na skalę użyteczności publicznej.\u003c\/li\u003e\n\u003cli\u003eCiągłe dostarczanie mocy dla dużych przemysłowych sprężarek powietrza i gazu odśrodkowego wykorzystujących szafy serii 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOznaczenie slotu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTyp zasilacza\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGórny slot \/ Dolny slot\u003c\/td\u003e\n\u003ctd\u003eLegacy wysokie napięcie stałe (88 do 140 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (firma Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e129486-01 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł zasilania stałym napięciem wysokiego napięcia 3500\/15 Legacy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne napięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 do 140 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny prąd pobierany przez pełną szafę\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,5 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOchrona przed zbyt niskim napięciem poza zakresem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNie uszkadza zasilacza ani PIM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOchrona przed nadmiernym napięciem poza zakresem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowoduje przepalenie bezpiecznika w odpowiadającym PIM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie systemu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrak wymaganego minimalnego obciążenia szafy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wilgotności względnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary fizyczne modułu (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga fizyczna modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja gniazd\u003c\/strong\u003e: Instaluj zasilacz wyłącznie w wyznaczonych gniazdach o połowie wysokości, znajdujących się po lewej stronie szafy systemu 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział redundancji\u003c\/strong\u003e: Przy wdrażaniu pary redundantnej umieść zasilacz podstawowy w dolnym gnieździe, a jednostkę zapasową bezpośrednio w górnym gnieździe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOchrona izolacji wejściowej\u003c\/strong\u003e: Sprawdź, czy sparowany moduł zasilania DC wysokiego napięcia (PIM) jest zainstalowany bezpośrednio za wyznaczonym gniazdem zasilania przed podłączeniem linii zasilających.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZarządzanie termiczne\u003c\/strong\u003e: Zapewnij, aby temperatura otoczenia szafy mieściła się w określonym zakresie roboczym od -30°C do +65°C, aby zachować trwałość wewnętrznych komponentów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa EMC\u003c\/strong\u003e: Spełnia wymagania Dyrektywy Wspólnoty Europejskiej 2014\/30\/EU na podstawie norm EN 61000-6-2 (odporność przemysłowa) oraz EN 61000-6-4 (emisje przemysłowe).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne\u003c\/strong\u003e: Spełnia wymagania Dyrektywy niskonapięciowej 2014\/35\/EU oraz parametry projektowe EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo środowiskowe\u003c\/strong\u003e: Zgodne z ograniczeniami europejskiej dyrektywy ROHS 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKlasyfikacje morskie\u003c\/strong\u003e: Formalnie zarejestrowane zgodnie z zasadami klasyfikacji DNV GL dla statków i jednostek offshore, wraz z zasadami ABS dla Warunków Klasyfikacji Część 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy dotyczące stref zagrożonych\u003c\/strong\u003e: Certyfikowane dla Klasy I, Strefy 2 (AEx\/Ex nA nC ic IIC T4 Gc \/ AEx\/Ex ec nC ic IIC T4 Gc) oraz Klasy I, Dywizji 2, Grup A, B, C i D w środowisku temperaturowym od -20°C do +65°C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519126379,"sku":"129486-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-129486-01-high-dc-power-supply-module-wvwdqpan0gu_14fe870c-2312-462b-a277-3e9beb1e5f01.jpg?v=1765440129"},{"product_id":"bently-nevada-3500-93-135785-01-system-display-unit","title":"Jednostka wyświetlacza systemu Bently Nevada 3500\/93 135785-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/93\u003c\/strong\u003e System wyświetlający służy do lokalnej wizualizacji danych monitoringu szafy w ramach systemu ochrony maszyn Bently Nevada 3500. \u003cstrong\u003e135785-01\u003c\/strong\u003e Jednostka wyświetlająca zapewnia interfejs LCD do przeglądania pomiarów kanałów, warunków alarmowych, informacji o stanie szafy oraz innych monitorowanych zmiennych z zainstalowanych modułów.\u003c\/p\u003e\n\u003cp\u003eZespół wyświetlacza współpracuje z modułem interfejsu wyświetlacza oraz modułem I\/O interfejsu wyświetlacza. Kontrolki membranowej klawiatury na froncie pozwalają operatorom nawigować po danych kanałów, zdarzeniach alarmowych i warunkach pracy szafy bezpośrednio z panelu wyświetlacza.\u003c\/p\u003e\n\u003cp\u003ePojedyncza szafa 3500 może obsługiwać do dwóch jednostek wyświetlających dla dodatkowej widoczności monitoringu w szafach ochrony maszyn lub zdalnych lokalizacjach operatorów. Wyświetlacz może być montowany bezpośrednio na przednim panelu szafy lub zainstalowany zdalnie w osobnej obudowie, w zależności od wymagań układu systemu.\u003c\/p\u003e\n\u003cp\u003eDiody LED na przednim panelu zapewniają wizualną informację o stanie kanału, kondycji szafy oraz aktywnych stanach alarmowych podczas pracy i czynności konserwacyjnych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKonsoliduje i wyświetla dane parametrów maszyn w czasie rzeczywistym zbierane ze wszystkich aktywnych kanałów szafy.\u003c\/li\u003e\n\u003cli\u003eWbudowany panel sterowania z klawiaturą umożliwia płynną nawigację operatora i lokalną kontrolę interfejsu wyświetlacza.\u003c\/li\u003e\n\u003cli\u003eZintegrowany wielosegmentowy system LED zapewnia wyraźne wskazania stanu kanału, nowych zdarzeń alarmowych, stanu jednostki wyświetlającej oraz stanu szafy.\u003c\/li\u003e\n\u003cli\u003eElastyczna infrastruktura montażowa umożliwia różnorodne układy na miejscu (montaż na froncie systemu, w szafie, na panelu oraz montaż niezależny).\u003c\/li\u003e\n\u003cli\u003eSolidna konstrukcja dostosowana do integracji w wymagających fizycznie środowiskach przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRozproszona wizualizacja stanu maszyn na dużych halach przemysłowych.\u003c\/li\u003e\n\u003cli\u003eNadzór nad krytycznymi zdarzeniami alarmowymi i rozwiązywanie problemów na poziomie pola w obudowach monitorujących 3500.\u003c\/li\u003e\n\u003cli\u003eLokalizowany wyświetlacz parametrów dla turbin parowych\/gazowych do wytwarzania energii oraz dużych sprężarek odśrodkowych.\u003c\/li\u003e\n\u003cli\u003eIntegracja panelu sterowania dla specjalistycznych platform maszyn morskich, petrochemicznych oraz naftowych i gazowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3500\/93: System wyświetlaczy systemowych\u003c\/li\u003e\n\u003cli\u003e135785-01: Zapasowa jednostka wyświetlacza 3500\/93\u003c\/li\u003e\n\u003cli\u003e137224-01: Zespół montażu systemu\u003c\/li\u003e\n\u003cli\u003e04344178: Śruba Phillips 10-32 x 0,37 z łbem panewkowym\u003c\/li\u003e\n\u003cli\u003e04309007: Śruba Phillips 4-40 x 0,62 z łbem panewkowym\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eKomponent produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eJednostka wyświetlacza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eElement wyświetlacza\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eModuł LCD (wersja refleksyjna bez podświetlenia \/ wersja transfleksyjna z podświetleniem)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eInterfejs użytkownika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eKlawiatura membranowa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eWskaźniki wizualne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eWyświetlacz parametrów maszyny LCD, diody LED statusu kanału, dioda LED nowego zdarzenia alarmowego, dioda LED statusu jednostki wyświetlacza, diody LED statusu szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eObsługiwane wyświetlacze na szafę\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eDo 2 wyświetlaczy systemowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-20°C do 65°C (-4°F do 149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e-30°C do 80°C (-22°F do 176°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eEmisje promieniowane\/przewodzone\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eEN 55011, Klasa A (zgodnie z dyrektywą EMC EN 50081-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eOdporność na wyładowania elektrostatyczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eEN 61000-4-2, Kryterium B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eOdporność na promieniowanie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eENV 50140, Kryterium A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eOdporność na szybkie impulsy elektryczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eEN 61000-4-4, Kryterium B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eOdporność na przepięcia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eEN 61000-4-5, Kryterium B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eNorma wymagań bezpieczeństwa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eEN 61010-01 (Dyrektywa niskonapięciowa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003ePin złącza \/ port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eKabel interfejsu D-Sub\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eŁączy jednostkę wyświetlacza 135785-01 z modułem interfejsu wyświetlacza hosta 3500\/93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOgraniczenia slotów:\u003c\/strong\u003e Przy wyborze konfiguracji montażu na froncie systemu, powiązany moduł interfejsu wyświetlacza 3500\/93 musi być zainstalowany konkretnie w slocie 15 szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSprawdzenie kompatybilności:\u003c\/strong\u003e Nie próbuj używać opcji montażu na froncie systemu 3500\/93 z mini-rackiem 3500\/05 lub 3500\/05 A02, ponieważ te konfiguracje fizyczne są niekompatybilne.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMontaż sprzętu:\u003c\/strong\u003e Zamontuj jednostkę wyświetlacza do zespołu montażowego systemu (137224-01) używając dokładnie czterech śrub Phillips 10-32 x 0,37 z łbem panewkowym.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePołączenie kabla:\u003c\/strong\u003e Przymocuj główny kabel interfejsu D-Sub solidnie do tylnego panelu modułu interfejsu wyświetlacza przed zamknięciem konstrukcji ramy montażowej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMocowanie obudowy:\u003c\/strong\u003e Otwórz ramy zespołu montażowego systemu w punktach obrotu i przymocuj je solidnie do szyn racka za pomocą czterech śrub Phillips pan head 4-40 x 0,62.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA-NRTL\/C Klasa I, Podział 2, Grupy A, B, C, D (T4 przy Tamb = 65°C)\u003c\/li\u003e\n\u003cli\u003eZnak CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest funkcja komponentu 135785-01 w konfiguracji 3500\/93?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo zewnętrzna jednostka wyświetlacza zapewnia fizyczny wyświetlacz LCD, diody LED statusu oraz interfejs klawiatury do śledzenia maszyn.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIle jednostek wyświetlacza systemu może być aktywnych na jednym racku 3500?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePojedynczy system monitorujący 3500 może obsługiwać maksymalnie do dwóch wyświetlaczy systemu 3500.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie rodzaje diod LED powiadamiających wizualnie są wbudowane w przedni panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFront panelu zawiera dedykowane diody LED wskazujące status kanału, nowe zdarzenia alarmowe, status jednostki wyświetlacza oraz ogólny status racka.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie są główne sposoby montażu tej jednostki wyświetlacza?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJednostka może być zainstalowana w konfiguracjach montażu na froncie systemu, montażu w racku, montażu panelowego lub montażu niezależnego.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy istnieją ograniczenia dotyczące slotów dla karty interfejsu przy użyciu zespołu montażu na froncie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, w konfiguracji montażu na froncie systemu moduł interfejsu wyświetlacza 3500\/93 musi być zainstalowany w slocie 15 racka.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy mogę użyć konfiguracji montażu na froncie z mini-rackiem Bently Nevada?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, opcja montażu na froncie systemu 3500\/93 jest całkowicie niekompatybilna z mini-rackami 3500\/05 i 3500\/05 A02.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaki zestaw sprzętowy jest potrzebny do wykonania typowego montażu na froncie systemu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWymaga to zespołu montażowego systemu 137224-01, czterech śrub 10-32 x 0,37 oraz czterech śrub 4-40 x 0,62.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaki interfejs kablowy obsługuje połączenie między wyświetlaczem a modułem interfejsu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePołączenie jest realizowane za pomocą dedykowanego kabla połączeniowego z interfejsem D-Sub.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten element zawiera podstawowy moduł interfejsu wyświetlacza backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, numer części 135785-01 odnosi się wyłącznie do zapasowego modułu wyświetlacza; karty interfejsu należy pozyskać osobno.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie parametry wilgotności środowiskowej należy utrzymywać podczas aktywnej pracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSprzęt musi działać w zakresie wilgotności względnej do 95%, bez kondensacji.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519224683,"sku":"3500\/93 135785-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-93-135785-01-system-display-module-eiqsqsxutmd_212a7fbb-ea9f-46f6-ac6b-564cf4fb0157.jpg?v=1765440131"},{"product_id":"bently-nevada-3500-50-133388-02-tachometer-module","title":"Moduł tachometru Bently Nevada 3500\/50 133388-02","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/50\u003c\/strong\u003e, oznaczony numerem części zamiennej \u003cstrong\u003e133388-02\u003c\/strong\u003e, jest dwukanałowym komponentem sprzętowym zaprojektowanym do określania prędkości obrotowej wału, przyspieszenia wirnika lub kierunku wirnika w systemie ochrony maszyn 3500. Moduł łączy się bezpośrednio z surowymi przetwornikami sond zbliżeniowych lub pasywnymi czujnikami magnetycznymi, aby monitorować dynamikę urządzeń fizycznych. Działając jako warstwa interfejsu analitycznego, ciągle porównuje pozyskane dane częstotliwościowe z programowalnymi przez użytkownika progami alarmowymi, zmieniając stany w celu uruchomienia automatycznych alarmów bezpieczeństwa po przekroczeniu progów. Konfigurowalny za pomocą oprogramowania 3500 Rack Configuration Software, moduł może dostarczać kondycjonowane sygnały Keyphasor do sieci szyny tylniej, eliminując potrzebę niezależnych instalacji sprzętu Keyphasor. Instrument wyprowadza niezależny analogowy sygnał rejestratora +4 do +20 mA dla każdego kanału pomiarowego, dostarczając operacjom zakładu i narzędziom rejestracji deterministyczne wskaźniki diagnostyczne.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePodwójne niezależne kanały do śledzenia częstotliwości wielopunktowej lub kierunku obrotu.\u003c\/li\u003e\n\u003cli\u003eWszechstronne przyjmowanie czujników obsługujące zarówno systemy sond zbliżeniowych prądów wirowych, jak i pasywne czujniki magnetyczne.\u003c\/li\u003e\n\u003cli\u003eCztery standardowe opcje oprogramowania układowego obejmujące monitorowanie prędkości, pasmo prędkości, zerową prędkość, przyspieszenie i śledzenie obrotów wstecznych.\u003c\/li\u003e\n\u003cli\u003eZintegrowana logika utrzymania szczytu rejestrująca maksymalną prędkość do przodu, maksymalną prędkość wsteczną oraz skumulowane obroty wsteczne.\u003c\/li\u003e\n\u003cli\u003eWewnętrzny rozdział sygnału w szafie dostarczający kondycjonowane dane referencyjne Keyphasor do sąsiednich monitorów serii 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eŚledzenie prędkości wału wirnika turbin parowych i gazowych oraz monitorowanie szczytowej prędkości obrotowej.\u003c\/li\u003e\n\u003cli\u003eObserwacja przyspieszenia sprężarki gazu procesowego odśrodkowego i interfejs awaryjnego wyłączania.\u003c\/li\u003e\n\u003cli\u003eWeryfikacja zerowej prędkości dużych wentylatorów chłodni kominowych i powiadomienie o obrocie wstecznym.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie stosunku prędkości wału wejściowego do wyjściowego w przemysłowych przekładniach o dużej mocy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/50-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModuł tachometru\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Typ modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z zakończeniami wewnętrznymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z zakończeniami zewnętrznymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O TMR z zakończeniami zewnętrznymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi i zakończeniami wewnętrznymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Opcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Użycie monitorujące\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003ePomiar prędkości \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eObrót wsteczny \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęści zamienne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e133388-02\u003c\/td\u003e\n\u003ctd\u003eModuł tachometru 3500\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/50 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133388-02 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKanały wejściowe sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 przetworniki sondy zbliżeniowej lub czujniki magnetyczne \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia sygnału wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10,0 V do -24,0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandardowa impedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa TMR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWewnętrzna impedancja wejściowa bariery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,15 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne zużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 5,8 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProporcjonalne wyjście rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 do +20 mA DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZgodność napięcia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do +12 V DC na obciążeniu \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres rezystancji obciążenia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do 600 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjście zasilania przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 V DC, maksymalnie 40 mA na kanał \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalna obsługiwana częstotliwość wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny zakres prędkości pełnej skali\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 999 obr.\/min \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres częstotliwości czujnika zbliżeniowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimalnie 0,0167 Hz (1 obr.\/min dla 1 zdarzenia\/obrót) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres częstotliwości czujnika magnetycznego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimalnie 3,3 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność obrotów na minutę (\u003c 100 obr.\/min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach ±0,1 obr.\/min \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność obrotów na minutę (100 do 10 000 obr.\/min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach ±1 obr.\/min \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność obrotów na minutę (\u003e 10 000 obr.\/min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach ±0,01% rzeczywistej prędkości wału \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność przyspieszenia wirnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach ±20 obr.\/min \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatyczna amplituda wyzwalania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimalnie 1 wolt od szczytu do szczytu \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRęczne wyzwalanie oscyloskopu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+9,5 V DC do -23,5 V DC z minimalnym sygnałem 500 mV od szczytu do szczytu \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRegulowana histereza wyzwalania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUżytkownik może wybrać od 0,2 do 2,5 wolta \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres opóźnienia alarmu 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund w odstępach 1 sekundy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres opóźnienia alarmu 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund w odstępach 0,1 sekundy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (standardowe WE\/WY)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 stopni Celsjusza do +65 stopni Celsjusza (-22 stopnie Fahrenheita do +150 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (WE\/WY z barierą)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 stopni Celsjusza do +65 stopni Celsjusza (32 stopnie Fahrenheita do 150 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatur przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 stopni Celsjusza do +85 stopni Celsjusza (-40 stopni Fahrenheita do +185 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalna wilgotność pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% wilgotności względnej bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,82 kg (1,8 funta) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu WE\/WY (bez bariery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,20 kg (0,44 funta) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu WE\/WY (bariera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 funta) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary głównego monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu WE\/WY (bez bariery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu WE\/WY (bariera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania dotyczące szafy montażowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowysokościowy slot przedni i 1 pełnowysokościowy slot tylny \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eZacisk \/ pin złącza\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH1 BNC (przedni panel)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuforowane wyjście koncentryczne przetwornika dla kanału 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH2 BNC (przedni panel)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuforowane wyjście koncentryczne przetwornika dla kanału 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePRZETWORNIKI WE\/WY (CH1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBloki zacisków PWR \/ COM \/ SIG \/ SHLD dla wejścia czujnika 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePRZETWORNIKI WE\/WY (CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBloki zacisków PWR \/ COM \/ SIG \/ SHLD dla wejścia czujnika 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlok zacisków KONTAKTÓW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlokady włączające RESET (PRST1 \/ PRST2) i barierę Zenera \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlok BUFROWANYCH PRZETWORNIKÓW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuforowane wyjścia w stylu euro do zewnętrznych oscyloskopów \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlok WYJŚĆ REJESTRATORA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane interfejsy pętli prądowej COM \/ REC1 \/ REC2 \/ SHLD \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSterowanie uziemieniem: Zakończ osłony kabli czujników polowych wyraźnie na wyznaczonych pinach SHLD na tylnych blokach zakończeniowych, aby zbudować skuteczną ścieżkę Faradaya przeciwko wysokoczęstotliwościowym zakłóceniom elektrycznym.\u003c\/li\u003e\n\u003cli\u003eWyrównanie gniazda: Włóż główny moduł przedni do dowolnego dostępnego gniazda pełnej wysokości, mocno dociskając wzdłuż ścieżek wyrównawczych, aż karta zaskoczy w linie zasilania płyty tylnej.\u003c\/li\u003e\n\u003cli\u003eWyłączenia czujników: Nie przypisuj wejść czujników magnetycznych do funkcji powiadamiania o zerowej prędkości lub obrotach wstecznych, ponieważ niska prędkość wału nie generuje ostrych sygnałów krawędziowych do prawidłowej interpretacji wyzwalacza.\u003c\/li\u003e\n\u003cli\u003eIntegralność wentylacji: Zapewnij zachowanie ścieżek odstępu zarówno na przedniej powierzchni, jak i w obszarach interfejsu tylnego, aby umożliwić przepływ wymuszonego powietrza przez obudowę urządzenia.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDyrektywy oznakowania CE: EN50081-2 Emisje promieniowane i przewodzone (Klasa A), EN50082-2 Standard odporności przemysłowej.\u003c\/li\u003e\n\u003cli\u003eDyrektywy niskonapięciowe: EN 61010-1 Wymagania dotyczące bezpieczeństwa środowiskowego urządzeń elektrycznych.\u003c\/li\u003e\n\u003cli\u003eCSA \/ NRTL \/ C: Certyfikowane do instalacji w Klasie I, Dywizji 2, Grupach A do D w połączeniu z odpowiednimi standardowymi modułami zakończeniowymi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne i zakupowe\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy to urządzenie może samodzielnie sterować zaworami wyłączającymi nadprędkość maszyn w zakładzie?\u003c\/strong\u003e O: Nie, moduły tachometru Bently Nevada nie są zaprojektowane jako komponenty do samodzielnej kontroli prędkości ani bezpośredniej ochrony przed nadprędkością, ponieważ nie posiadają krytycznej redundancji strukturalnej potrzebnej do funkcji wyłączania maszyn.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jaka jest fizyczna różnica operacyjna między numerem części 133388-02 a oznaczeniem serii 3500\/50?\u003c\/strong\u003e O: 3500\/50 oznacza ogólną rodzinę modułów tachometru funkcjonalnego, natomiast odniesienie 133388-02 określa konkretny identyfikator zapasowego komponentu magazynowego dla przedniego zespołu karty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy konieczna jest ręczna kalibracja pętli wyjścia analogowego po uruchomieniu?\u003c\/strong\u003e O: Nie, nie są potrzebne żadne procedury kalibracji na poziomie pola, ponieważ wszystkie zakresy wejściowe nadajnika, progi napięciowe i parametry dyskretne są przetwarzane cyfrowo za pomocą warstwy oprogramowania 3500.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy można bezpiecznie przypisać czujnik magnetyczny do weryfikacji zachowania obrotów wstecznych?\u003c\/strong\u003e O: Nie, pasywne czujniki magnetyczne nie dostarczają wyraźnego ani czystego sygnału krawędzi podczas wolnych lub zatrzymujących się cykli wału, co może powodować poważne błędy lub nieprawidłowe śledzenie kierunku w warstwie logiki.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jak nagłe zewnętrzne zwarcie w pętli rejestratora analogowego wpływa na ogólne śledzenie prędkości?\u003c\/strong\u003e O: Podstawowe operacje śledzenia prędkości, monitorowania alarmów oraz przetwarzania na płycie tylnej pozostają całkowicie niewrażliwe na zwarcia w pętlach zewnętrznej linii rejestratora.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519552363,"sku":"3500\/50 133388-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-50-133388-02-tachometer-module-fzrkzbolckl_a2fc124d-c18b-438a-9eb8-c8d07efe8699.jpg?v=1765440133"},{"product_id":"bently-nevada-133442-01-3500-50m-i-o-module-with-internal-terminations","title":"Bently Nevada 133442-01 3500\/50M I\/O Module with Internal Terminations","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel Tachometer Input\/Output (I\/O) module designed for the 3500 Series Machinery Protection System. This module serves as the primary physical interface for field wiring, specifically engineered to operate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTachometer Main Modules. It processes high-frequency pulse inputs from proximity probes or passive magnetic pickups to facilitate precise measurements of rotational speed, rotor acceleration, and reverse rotation.\u003c\/p\u003e\n\u003cp\u003eAs an internal termination variant, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures integrated screw terminal blocks directly on the module body, optimizing it for high-density cabinet installations where space is a priority. This hardware configuration is widely deployed in power generation, petrochemical, and gas compression facilities for continuous machinery monitoring and critical overspeed protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTachometer I\/O Module with Internal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-channel differential or single-ended pulse inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity probe systems, Magnetic pickups\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+10.0 Vdc to -24.0 Vdc (internally limited)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.15 kΩ (Internal Barrier variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 163.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg (1.01 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 deg C to +65 deg C (-22 deg F to +149 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eWhen procuring spare parts, ensure the part number matches the specific rack configuration to avoid hardware\/software mismatch errors.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComponent Description\u003c\/strong\u003e: 3500\/50M Tachometer I\/O Module with Internal Terminations (Internal Barrier Type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated Main Module\u003c\/strong\u003e: 3500\/50-01-XX or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M-01-XX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Fixed screw terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003ch3\u003eWiring and Shielding Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection\u003c\/strong\u003e: Use twisted, shielded pair cabling (18 AWG to 22 AWG) for all transducer connections to mitigate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Connect shields to the designated instrument ground terminal on the 3500 rack chassis at one end only. Do not ground at the field transducer to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Separation\u003c\/strong\u003e: Maintain a minimum distance of 300 mm (12 inches) between speed sensor cables and high-voltage AC power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Hot-Swap Precautions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Alignment\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be installed in the rear slot corresponding to the front-mounted 3500\/50M main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBypass Protocol\u003c\/strong\u003e: Prior to module extraction or insertion, bypass all associated machinery trip relays to prevent accidental turbine or compressor trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Limits\u003c\/strong\u003e: Tighten terminal block screws to a maximum of 0.56 N·m (5 in·lb) to protect the internal PCB traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 133442-01 compatible with older 3500\/50 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is fully backwards compatible with standard 3500\/50 and upgraded 3500\/50M modules, provided the rack configuration software matches the hardware variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and the External Termination (ET) version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures built-in terminal blocks. The ET version requires a multi-pin cable to connect to a remote DIN-rail terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the risks of exceeding the input signal range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile internal clipping circuits limit voltages, sustained overvoltage outside the +10V to -24V range can degrade the internal barrier circuitry and cause channel faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519650667,"sku":"133442-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133442-01-i-o-module-with-internal-terminations-1a4iq1cd4r4_bc83d92f-d0df-4c88-95ae-2fed0e219041.jpg?v=1765440137"},{"product_id":"bently-nevada-3500-94-145988-01-vga-display-module","title":"Moduł wyświetlacza VGA Bently Nevada 3500\/94 145988-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003eBently Nevada 3500\/94 145988-01\u003c\/strong\u003e to wysokowydajny \u003cstrong\u003emoduł wyświetlacza VGA\u003c\/strong\u003e należący do \u003cstrong\u003esystemu ochrony maszyn serii 3500\u003c\/strong\u003e. Moduł ten jest zaprojektowany do zbierania, przetwarzania i wyświetlania krytycznych danych bezpośrednio z szafy systemowej, służąc jako scentralizowany interfejs człowiek-maszyna dla operatorów zakładu i inżynierów utrzymania ruchu.\u003c\/p\u003e\n\u003cp\u003eModuł \u003cstrong\u003e3500\/94\u003c\/strong\u003e (oznaczany także jako \u003cstrong\u003e3500\/94M\u003c\/strong\u003e) wyświetla kompleksowe metryki ochrony maszyn, w tym listy zdarzeń systemowych, listy alarmów, pomiary poszczególnych modułów i kanałów oraz statusy OK lub alarmowe w czasie rzeczywistym. Korzystając z \u003cstrong\u003eoprogramowania konfiguracyjnego szafy 3500\u003c\/strong\u003e, użytkownicy mogą tworzyć do dziewięciu niestandardowych ekranów wyświetlacza zorganizowanych według grup zespołów maszynowych lub indywidualnych wymagań układu. Domyślnie prekonfigurowane układy prezentują filtrowane pomiary drgań 1X w formie wykresów słupkowych wraz z wartościami szczeliny przetwornika zbliżeniowego. System obsługuje bezpośrednie interfejsy do przemysłowych wyświetlaczy dotykowych 10- lub 15-calowych, monitorowanie wieloszafkowe za pomocą opcjonalnego routera wyświetlacza oraz rozszerzoną łączność światłowodową zdalną przez rozszerzniki KVM dla bezpiecznego, długodystansowego dostępu do danych w dużych środowiskach przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWyświetlanie pełnych list zdarzeń systemowych, list alarmów oraz kompleksowych danych kanałów.\u003c\/li\u003e\n\u003cli\u003eObsługa do dziewięciu niestandardowych konfiguracji wyświetlacza na moduł za pomocą oprogramowania szafkowego.\u003c\/li\u003e\n\u003cli\u003eCiągły monitoring i wizualne wskazania alarmów oraz statusu OK.\u003c\/li\u003e\n\u003cli\u003eMożliwości wieloszafkowe pozwalające na podłączenie do czterech szaf 3500 na jednym wyświetlaczu za pomocą routera.\u003c\/li\u003e\n\u003cli\u003eDiodowe wskaźniki statusu na panelu przednim wskazujące komunikację systemową i działanie modułu.\u003c\/li\u003e\n\u003cli\u003eIntegracja z portem przednim zapewniająca wyjście zasilania 24 V DC, wyjście sygnału VGA oraz trasowanie poleceń dotykowych.\u003c\/li\u003e\n\u003cli\u003eKompatybilność z certyfikowanym przemysłowym sprzętem dotykowym do stref zagrożonych wybuchem.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentralny wyświetlacz drgań maszyn wieloszafkowych\u003c\/li\u003e\n\u003cli\u003eŚledzenie statusu dużych turbin parowych i gazowych\u003c\/li\u003e\n\u003cli\u003eStacje monitorowania sprężarek i pomp o wysokiej prędkości\u003c\/li\u003e\n\u003cli\u003eZdalne panele operatorskie przez długodystansowe rozszerzenie KVM\u003c\/li\u003e\n\u003cli\u003eLokalizowany monitoring zakładów petrochemicznych i elektrowni\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eKategoria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eMarka\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eModel i główny numer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eNumer części\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e145988-01 (3500\/94 \/ 3500\/94M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eWymagania zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eZużycie energii\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eMaks. 4,6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eWejścia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eSieć wysokiej prędkości\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eStatus monitora, dane i wartości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003ePort RS232 (I\/O)\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eDane kontrolera dotykowego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eWyjścia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eDioda OK\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eWskazuje prawidłową pracę modułu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eDioda TX\/RX\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eWskazuje komunikację między innymi modułami systemu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003ePort VGA (I\/O)\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eAnalogowe sygnały czerwony, zielony, niebieski oraz synchronizacji do wyświetlacza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003ePort przedni\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eWyjście zasilania 24 V DC, wyjście sygnału VGA, wejście poleceń dotykowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eOgraniczenia środowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e-20 Celsius do 65 Celsius (-22 Fahrenheit do 149 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e-40 Celsius do 85 Celsius (-40 Fahrenheit do 185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eWilgotność\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eCharakterystyka fizyczna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eWymiary (W x S x G)\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e241,3 mm x 24,4 mm x 241,8 mm (9,5 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eWaga\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e0,73 kg (1,6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eZłącze\/Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003ePort przedni\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eDostarcza wyjście zasilania 24 Vdc, wyprowadza standardowy sygnał wideo VGA oraz odbiera przychodzące polecenia dotykowe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003ePort VGA (moduł I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eWyprowadza analogowe sygnały czerwony, zielony, niebieski oraz synchronizacji bezpośrednio do monitora przemysłowego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003ePort RS232 (moduł I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDo obsługi komunikacji i danych odpowiedzi kontrolera dotykowego przychodzących i wychodzących\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardowe limity odległości:\u003c\/strong\u003e Standardowe kable VGA pozwalają na montaż monitora w maksymalnej odległości 6 m (20 stóp) od szafy 3500 lub skrzynki Display Router. Przekroczenie tego limitu pogarsza jakość obrazu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpcje zdalne na duże odległości:\u003c\/strong\u003e Do instalacji zdalnych od 10 m do 10 km (33 stóp do 6,2 mil) zastosować Single-mode Fiber Optic (SM FO) przedłużacz klawiatury, wideo i monitora (KVM).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedukcja zakłóceń elektrycznych:\u003c\/strong\u003e Unikać prowadzenia linii sygnału VGA przez silnie zakłócone środowiska elektroniczne, aby zapewnić stabilną rozdzielczość obrazu i synchronizację.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZasilanie wyświetlacza:\u003c\/strong\u003e Zarówno 10-calowe, jak i 15-calowe wyświetlacze dotykowe wymagają niezależnych zewnętrznych źródeł zasilania; nie mogą być zasilane wyłącznie przez port interfejsu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIzolacja stref zagrożonych:\u003c\/strong\u003e Przy użyciu odbiornika i nadajnika Single-mode Fiber Optic KVM oba urządzenia muszą być zamontowane w wyznaczonej bezpiecznej strefie lub umieszczone w zaprojektowanej, zatwierdzonej obudowie przeciwwybuchowej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZgodność FCC:\u003c\/strong\u003e Zgodne z częścią 15 przepisów FCC (eksploatacja pod warunkiem braku szkodliwych zakłóceń i akceptacji wszelkich otrzymanych zakłóceń).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e Dyrektywa 2014\/30\/UE; Normy EN 61000-6-2, EN 61000-6-4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Dyrektywa 2014\/35\/UE; Normy CSA C22.2 61010-1, UL EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Dyrektywa 2011\/65\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty modułu do stref zagrożonych (Opcja 01 - Ameryka Północna):\u003c\/strong\u003e Kanada: Ex nC [L] IIC T4 Gc (CSA60079-0, -11, -15), Klasa I, Dywizja 2, Grupy A, B, C, D (CSA213). USA: Klasa I, Strefa 2: AEx nC IIC T4 Gc (UL60079-0, -11, -15), Klasa I, Dywizja 2, Grupy A, B, C, D (ISA 12.12.01). Temperatura pracy T4 @ -20 Celsius \u0026lt;= Ta \u0026lt;= +65 Celsius zgodnie z rysunkiem sterującym 149243.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty modułu do stref zagrożonych (Opcja 02 - ATEX\/IECEx):\u003c\/strong\u003e II 3 G, Ex nA nC ic IIC T4 Gc, T4 @ -20 Celsius \u0026lt;= Ta \u0026lt;= +65 Celsius zgodnie z rysunkiem sterującym 149243.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyświetlacz Advantech 10\" (AN-D3510) Zatwierdzenia:\u003c\/strong\u003e Ameryka Północna Opcja 01: Ex ic nA IIC T4 (CSA C22.2 60079-0, -11, -15), Klasa I, Dywizja 2, Grupy A, B, C, D T4 (CSA C22.2 213); USA Klasa I, Dywizja 2, Grupy A, B, C, D T4 (ISA 12.12.01), Klasa I, Strefa 2, AEx ic nA IIC T4 (UL60079-0, -11, -15). ATEX\/IECEx Opcja 02: II 3G Ex ic nA IIC T4 Gc, IP54.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyświetlacz Advantech 15\" (FPM-8151) Uwaga:\u003c\/strong\u003e Nie posiada certyfikatów zgodności z normami ATEX\/IECEx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJakie informacje można wyświetlać za pomocą tego modułu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWyświetla listy zdarzeń systemowych, listy alarmów, dane operacyjne modułów i kanałów oraz ogólny status systemu OK lub alarmu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIle niestandardowych ekranów wyświetlacza można skonfigurować na urządzeniu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMożna skonfigurować do dziewięciu niestandardowych ekranów za pomocą oprogramowania do konfiguracji rdzenia szafy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie są domyślne, wstępnie skonfigurowane układy ekranów?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePierwszy domyślny ekran pokazuje wykres słupkowy pomiarów drgań filtrowanych 1X, a drugi wartości szczeliny przetwornika zbliżeniowego.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy dane z wielu szaf monitorów mogą być agregowane na jednym wyświetlaczu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, opcjonalny Router Wyświetlacza pozwala na podłączenie do czterech oddzielnych szaf do jednego monitora.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest maksymalna bezpośrednia długość okablowania między szafą a routerem wyświetlacza?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaksymalna zalecana długość okablowania to 6 metrów lub 20 stóp ze względu na ograniczenia standardu sygnału VGA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak można przesunąć monitor wyświetlacza dalej niż 6 metrów od szafy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDo przesyłania sygnałów na większe odległości należy zastosować przedłużacz klawiatura-wideo-monitor światłowodowy jednomodowy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest maksymalna osiągalna odległość przy użyciu przedłużaczy światłowodowych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDane mogą być przesyłane na odległość do 10 kilometrów lub 6,2 mil bez utraty jakości obrazu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy przedłużacze KVM są certyfikowane do bezpośredniego umieszczenia w środowiskach zagrożonych wybuchem?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, zarówno nadajnik, jak i odbiornik światłowodowy muszą znajdować się w strefach bezpiecznych lub być umieszczone w zatwierdzonych obudowach ochronnych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie rozmiary przemysłowych wyświetlaczy dotykowych są oficjalnie wspierane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSystem obsługuje formaty przemysłowych wyświetlaczy dotykowych 10-calowych i 15-calowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy obie opcje wyświetlaczy 10-calowego i 15-calowego są bezpieczne do stref ATEX?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTylko wyświetlacz 10-calowy posiada certyfikaty ATEX i IECEx, natomiast opcja wyświetlacza 15-calowego nie spełnia tych norm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo pokazują diody LED na przednim panelu podczas normalnej pracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDioda LED OK wskazuje, że główny moduł wyświetlacza działa poprawnie, natomiast dioda TX\/RX sygnalizuje standardową komunikację wewnątrz szafy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest całkowita wewnętrzna moc zużywana przez główną kartę modułu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł pobiera maksymalnie 4,6 wata mocy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519847275,"sku":"145988-01","price":3500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-94-145988-01-vga-display-monitor-ijpyu2p25hi_10a55afc-a9cf-4660-b88b-0f006d61d756.jpg?v=1765440142"},{"product_id":"bently-nevada-3500-62-163179-03-process-variable-monitor","title":"Bently Nevada 3500\/62 163179-03 Monitor zmiennych procesowych","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/62\u003c\/strong\u003e monitor zmiennych procesowych, identyfikowany pod numerem części \u003cstrong\u003e163179-03\u003c\/strong\u003e, to 6-kanałowy instrument sprzętowy zaprojektowany do przetwarzania krytycznych parametrów maszyn, które wymagają ciągłego monitorowania, w tym ciśnień, przepływów, poziomów i temperatur. Moduł współpracuje z zewnętrznymi nadajnikami polowymi, akceptując pętle prądowe +4 do +20 mA lub dowolne proporcjonalne wejścia napięciowe w zakresie od -10 VDC do +10 VDC. Wykonuje kondycjonowanie sygnału w czasie rzeczywistym, mapując surowe wartości na skonfigurowany zakres do 20 000 jednostek cyfrowych, i porównuje te zmienne procesowe na żywo z programowalnymi przez użytkownika dwupoziomowymi progami alarmowymi (Alert i Danger). Działając przez magistralę 3500, jednostka dostarcza deterministyczne wskaźniki stanu maszyny dla personelu operacyjnego i utrzymaniowego, zapewnia funkcje logiki głosowania dla architektur potrójnej redundancji modułowej (TMR) oraz łączy się bezpośrednio z warstwą konfiguracji szafy systemowej, aby utrzymać zautomatyzowaną ochronę maszyn.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSześć kanałów pomiarowych o wysokiej gęstości, programowalnych przez oprogramowanie.\u003c\/li\u003e\n\u003cli\u003eWybieralne opcje wejść analogowych obsługujące ±10 VDC i wejścia 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eProgramowalna matryca alarmowa obsługująca zmienne Alert i Danger z dyskretnymi opóźnieniami poniżej sekundy.\u003c\/li\u003e\n\u003cli\u003eZintegrowane cyfrowe kondycjonowanie sygnału eliminujące konieczność kalibracji w terenie.\u003c\/li\u003e\n\u003cli\u003eWbudowana diagnostyka LED do weryfikacji stanu modułu i wymiany danych na magistrali szafy w czasie rzeczywistym.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitorowanie ciśnienia i przepływu cieczy w linii zasilającej hydrodynamicznego systemu smarowania olejem.\u003c\/li\u003e\n\u003cli\u003eŚledzenie ciśnienia na etapie sprężarki turbiny gazowej lub w punkcie ssania.\u003c\/li\u003e\n\u003cli\u003eIntegracja poziomu cieczy procesowej i obiegu rozkładu ciepła w obudowie pompy przemysłowej.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie ciśnienia tłoka równoważącego i rozszerzania obudowy w maszynach procesowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e163179-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLiczba kanałów\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kanałów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wejścia napięciowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 VDC do +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wejścia prądowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa (wejście napięciowe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa (wejście prądowe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne zużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo 7,0 watów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZgodność napięciowa (I\/O z barierą)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,66 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNapięcie izolacji (izolowane I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjście zasilania przetwornika (I\/O z barierą)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24 VDC ± 5% przy maks. 250 mA (z bezpiecznikiem)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność kondycjonowania sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo w granicach ±0,33% pełnej skali, maksymalnie ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePełna zdolność odwzorowania skali\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksymalnie 20 000 jednostek odwzorowanych na zakresie sygnału\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalny zakres napięcia wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 wolty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność nastawy alarmu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach 0,13% od żądanej wartości docelowej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterwał opóźnienia czasu alarmu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund z przyrostem co 1 sekundę\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterwał opóźnienia czasu zagrożenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund z przyrostem co 0,5 sekundy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (standardowe I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 stopni Celsjusza do +65 stopni Celsjusza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (bariera I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 stopni Celsjusza do +65 stopni Celsjusza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 stopni Celsjusza do +85 stopni Celsjusza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wilgotności pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% wilgotności względnej bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O (bez bariery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O (z barierą)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,46 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary głównego monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania dotyczące miejsca w szafie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe gniazdo z przodu i 1 pełnowymiarowe gniazdo z tyłu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUziemienie i ekranowanie: Podłącz ekrany kabli przyrządowych wyłącznie do wyznaczonych zacisków na tylnym module I\/O, zapewniając izolację ekranu na końcu czujnika polowego, aby zminimalizować zakłócenia elektromagnetyczne.\u003c\/li\u003e\n\u003cli\u003ePrzydział gniazd: Włóż główny moduł sprzętowy do dowolnego pełnowymiarowego gniazda po prawej stronie modułu Transient Data Interface w obudowie 3500.\u003c\/li\u003e\n\u003cli\u003eTrasowanie kabli: Oddzielaj pary sygnałowe niskonapięciowych nadajników od aktywnych przekaźników sterujących AC i pętli zasilania maszyn, aby uniknąć sprzężenia szumów indukcyjnych.\u003c\/li\u003e\n\u003cli\u003eZarządzanie termiczne: Zachowaj wolne strefy powietrzne nad i pod obudową szafy 3500, aby zapewnić niezakłóconą pasywną wentylację i chłodzenie powietrzem.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ techniczne i zakupowe\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Czy ta konkretna część może obsługiwać mieszankę sygnałów napięciowych i prądowych na swoich sześciu gniazdach?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Nie, architektura sprzętu wejściowego jest określona przez konkretny typ tylnego modułu I\/O przypisanego do gniazda, co oznacza, że wszystkie sześć kanałów musi być jednolicie skonfigurowane jako pętle napięciowe lub prądowe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Jakie znaczenie ma numer części 163179-03 w odniesieniu do ogólnego modelu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Numer 163179-03 określa dokładną fabryczną nazwę części zamiennej dla modułu głównego monitora zmiennej procesowej z przodu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Jak system reaguje, jeśli prąd wejściowy w pętli spadnie znacznie poniżej progu 4 mA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Monitor interpretuje sygnał prądu poniżej zakresu jako usterkę przetwornika, obniża wskaźnik statusu kanału OK, aby zapobiec fałszywym wyzwoleniom, i rejestruje kod błędu Not OK.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Czy podczas corocznych przeglądów instrumentów wymagana jest zewnętrzna kalibracja warstwy przetwarzania analogowego?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Nie są potrzebne fizyczne procedury kalibracji, ponieważ wszystkie skalowania, przesunięcia napięcia i zmienne jednostek inżynierskich są obliczane matematycznie za pomocą cyfrowego środowiska konfiguracyjnego.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Jaki jest funkcjonalny wpływ aktywacji diody LED Bypass na przednim panelu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Wskaźnik informuje, że macierz alarmowa dla jednego lub więcej pętli procesowych została wyłączona, co zapobiega uruchomieniu awaryjnych wyłączników sprzętowych podczas konserwacji czujników na żywo.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519945579,"sku":"3500\/62 163179-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-62-163179-03-process-variable-monitor-43f32qa12ju_dd6bb116-d3a6-4c1d-8b1c-2462de80a7fb.jpg?v=1765440143"},{"product_id":"bently-nevada-3500-77m-140734-07-recip-cylinder-pressure-monitor","title":"Bently Nevada 3500\/77M 140734-07 Monitor ciśnienia cylindra tłokowego","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eKarta \u003cstrong\u003eBently Nevada 3500\/77M 140734-07\u003c\/strong\u003e to 4-kanałowa karta do ciągłej ochrony i monitorowania maszyn zaprojektowana dla \u003cstrong\u003eSystemu wykrywania maszyn serii 3500\u003c\/strong\u003e. Bezpośrednio współpracuje z zatwierdzonymi przez Bently Nevada dodatnimi przetwornikami ciśnienia stron trzecich (psia), aby mierzyć, kondycjonować i analizować wartości ciśnienia w cylindrach sprężarek tłokowych.\u003c\/p\u003e\n\u003cp\u003eGłówną funkcją \u003cstrong\u003e3500\/77M\u003c\/strong\u003e ma na celu zapewnienie ciągłej ochrony maszyn poprzez porównywanie przetworzonych parametrów z programowalnymi progami alarmowymi w oprogramowaniu, aby wywołać automatyczne alerty systemowe lub wyłączenia maszyn. Jednocześnie dostarcza kompleksowe proporcjonalne wartości fizyczne (PPL) wymagane przez inżynierów operacji i utrzymania do monitorowania integralności sprzętu. W zależności od parametrów konfiguracji, każdy kanał generuje osiem odrębnych wartości PPL. Pięć z nich jest dedykowanych metrykom jednoprzestrzennym (ciśnienie tłoczenia, ciśnienie ssania, ciśnienie maksymalne, ciśnienie minimalne oraz współczynnik sprężania), natomiast trzy to zaawansowane obliczenia obciążenia mechanicznego oparte na metrykach międzykanałowych i fizycznym układzie ramy (szczytowe ściskanie pręta, szczytowe rozciąganie pręta oraz stopień odwrócenia pręta).\u003c\/p\u003e\n\u003ch3\u003eFunkcje\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eArchitektura czterokanałowa obsługująca do czterech niezależnych wejść przetworników ciśnienia.\u003c\/li\u003e\n\u003cli\u003eŚledzenie w czasie rzeczywistym ośmiu wartości proporcjonalnych (PPL) na aktywny kanał dla kompleksowej analizy cylindrów.\u003c\/li\u003e\n\u003cli\u003eWbudowana logika ochrony maszyn porównująca punkty danych bezpośrednio z konfigurowalnymi progami alarmowymi i niebezpieczeństwa.\u003c\/li\u003e\n\u003cli\u003eWspółosiowe, zabezpieczone przed zwarciem, buforowane wyjścia przetworników umieszczone na przednim panelu.\u003c\/li\u003e\n\u003cli\u003eDynamiczne obliczanie sił obciążenia pręta, w tym szczytowego ściskania pręta, szczytowego rozciągania pręta oraz stopnia odwrócenia pręta.\u003c\/li\u003e\n\u003cli\u003eDiody LED na przednim panelu do lokalnej identyfikacji działania modułu, komunikacji wewnątrz szafy oraz aktywnego stanu obejścia.\u003c\/li\u003e\n\u003cli\u003ePełna kompatybilność z modułami I\/O ciśnienia cylindrów z zakończeniem wewnętrznym i zewnętrznym.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitorowanie cylindrów sprężarek tłokowych\u003c\/li\u003e\n\u003cli\u003eObliczanie obciążenia pręta i odwrócenia pręta\u003c\/li\u003e\n\u003cli\u003eOchrona sprężarek gazu procesowego petrochemicznego\u003c\/li\u003e\n\u003cli\u003eMonitorowanie stacji przesyłowej gazu ziemnego\u003c\/li\u003e\n\u003cli\u003eKrytyczna diagnostyka maszyn tłokowych\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eKategoria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eMarka\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eNumer modelu\/części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eNumer części\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e140734-07 (3500\/77M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eKanały wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eTyp sygnału\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e1 do 4 kanałów dodatniego napięcia zewnętrznych przetworników ciśnienia (psia)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eWspółczynniki skali przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eZakres 100 psia\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e95000 uV\/psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eZakres 250 psia\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e38000 uV\/psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eZakres 500 psia\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e19000 uV\/psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eZakres 1000 psia\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e9500 uV\/psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eZakres 2500 psia\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e3800 uV\/psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eZakres 5000 psia\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1900 uV\/psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eZakres 10000 psia\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e950 uV\/psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eWskaźnik skali odniesienia\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eZakłada +0,5 V DC przy 0 psia i +10,0 V DC przy pełnym zakresie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eKondycjonowanie sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003ePasmo przenoszenia\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e0 do 5,5 kHz na wszystkich skonfigurowanych kanałach ciśnienia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eImpedancja wejściowa\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e50 kOm (Cylinder Pressure I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eDokładność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eTemperatura przy +25 stopniach Celsjusza\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eW granicach ± 0,5% pełnego zakresu przetwornika ciśnienia (9,5 V: od +0,5 do +10,0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eTemperatura od -30 do +65 stopni Celsjusza\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eW granicach ± 1,0% pełnego zakresu przetwornika ciśnienia (9,5 V: od +0,5 do +10,0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eWymagania zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eZużycie energii\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e7,8 W, przy pełnym obciążeniu zasilania przetwornika\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eWyjścia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003eDioda LED OK\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003eWskazuje prawidłową pracę monitora\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003eDioda LED TX\/RX\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003eWskazuje komunikację z innymi modułami w racku 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003eDioda LED obejścia\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003eWskazuje, gdy moduł jest w trybie obejścia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003eBuforowane wyjścia przetwornika\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e1 złącze koncentryczne na kanał, zabezpieczone przed zwarciem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"22\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"22\"\u003eImpedancja wyjścia buforowanego\u003c\/td\u003e\n\u003ctd data-row=\"22\"\u003e550 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"23\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"23\"\u003eZasilanie przetwornika\u003c\/td\u003e\n\u003ctd data-row=\"23\"\u003e+23,0 ± 0,8 V DC z ograniczeniem prądu 24,5 mA na każdy kanał\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"24\"\u003e\u003cstrong\u003eOgraniczenia środowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"24\"\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd data-row=\"24\"\u003e-30 stopni Celsjusza do +65 stopni Celsjusza (-22 stopni Fahrenheita do +150 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"25\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"25\"\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd data-row=\"25\"\u003e-40 stopni Celsjusza do +85 stopni Celsjusza (-40 stopni Fahrenheita do +185 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"26\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"26\"\u003eWilgotność\u003c\/td\u003e\n\u003ctd data-row=\"26\"\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"27\"\u003e\u003cstrong\u003eAtrybuty fizyczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"27\"\u003eWymiary monitora (W x S x G)\u003c\/td\u003e\n\u003ctd data-row=\"27\"\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"28\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"28\"\u003eWaga monitora\u003c\/td\u003e\n\u003ctd data-row=\"28\"\u003e0,91 kg (2,0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfejs przetwornika:\u003c\/strong\u003e Podłączaj tylko dodatnie napięcie, zewnętrzne absolutne przetworniki ciśnienia (psia) zatwierdzone przez Bently Nevada, o zakresie wyjściowym od +0,5 V DC do +10,0 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUwaga dotycząca sygnału wyjść buforowanych I\/O:\u003c\/strong\u003e Podczas monitorowania za pomocą modułu Cylinder Pressure I\/O należy pamiętać, że buforowane wyjścia przetwornika na przednich złączach koncentrycznych są odwrócone i przesunięte o -2,265 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja zakończenia:\u003c\/strong\u003e Dopasuj konkretną konfigurację do wewnętrznych lub zewnętrznych bloków zakończeniowych w zależności od wersji modułu Cylinder Pressure I\/O zainstalowanego w slocie racka.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWprowadzanie parametrów mechanicznych:\u003c\/strong\u003e Dokładne obliczenie wartości proporcjonalnych międzykanałowych (szczytowe ściskanie pręta, szczytowe napięcie pręta oraz stopień odwrócenia pręta) wymaga precyzyjnego wprowadzenia komponentów mechanicznych sprężarki w oprogramowaniu konfiguracyjnym szafy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWymagania termiczne:\u003c\/strong\u003e Upewnij się, że warunki otoczenia pracy wokół szafy 3500 nie przekraczają określonych limitów od -30 do +65 stopni Celsjusza.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty do stref zagrożenia:\u003c\/strong\u003e CSA\/NRTL\/C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest główny cel tego modułu w ramach szafy 3500?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł nieustannie monitoruje ciśnienia cylindrów sprężarki tłokowej, aby zapewnić ochronę maszyn i obliczać niezbędne parametry operacyjne.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIle kanałów ciśnieniowych obsługuje pojedynczy moduł?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eObsługuje od 1 do 4 niezależnych kanałów przetworników ciśnienia.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie typy czujników są kompatybilne z wejściami?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eObsługuje dodatnie napięcie, zatwierdzone przez Bently Nevada zewnętrzne absolutne przetworniki ciśnienia (psia).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie bazowe napięcia wyjściowe są zakładane dla współczynników skali czujnika ciśnienia?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWspółczynniki skali zakładają absolutne napięcie bazowe +0,5 V DC przy 0 psia oraz +10,0 V DC przy wyznaczonym zakresie ciśnienia pełnej skali czujnika.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie pięć pojedynczych wartości proporcjonalnych komory jest obliczanych przez kartę?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWartości to ciśnienie tłoczenia, ciśnienie ssania, ciśnienie maksymalne, ciśnienie minimalne oraz współczynnik sprężania.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie trzy wielokanałowe parametry łączone są obliczane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eParametry obejmują szczytowe ściskanie pręta, szczytowe napięcie pręta oraz stopień odwrócenia pręta.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIle punktów nastaw niebezpieczeństwa można skonfigurować na kanał?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePunkty nastaw niebezpieczeństwa (przekroczenie prędkości\/ciśnienia) mogą być wyraźnie przypisane do dowolnych dwóch aktywnych wartości proporcjonalnych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy buforowane wyjścia przetworników na przednim panelu są modyfikowane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, przy użyciu modułu Cylinder Pressure I\/O, buforowane wyjścia koncentryczne na przednim panelu są odwrócone i przesunięte o -2,265 V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest limit prądu elektrycznego na zintegrowanym zasilaniu czujnika?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł posiada wyjście zasilania +23,0 V DC z funkcją ograniczenia prądu 24,5 mA wbudowaną w każdy indywidualny kanał.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest odpowiedź częstotliwościowa przetwarzania sygnału karty ciśnieniowej?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł zapewnia odpowiedź częstotliwościową od 0 do 5,5 kHz na wszystkich aktywnych, skonfigurowanych kanałach.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy zwarcie na buforowanym wyjściu na przednim panelu uszkadza urządzenie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, wszystkie przednie połączenia buforowanych przetworników koncentrycznych są w pełni chronione przed zwarciem.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520043883,"sku":"140734-07","price":3500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-77m-140734-07-i-o-recip-cylinder-pressure-monitor-rj3dp1htahx_b7413fd4-2415-49db-86cf-d4a2970ff409.jpg?v=1765440144"},{"product_id":"bently-nevada-3500-53-133388-01-overspeed-detection-module","title":"Moduł wykrywania przekroczenia prędkości Bently Nevada 3500\/53 133388-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/53 133388-01\u003c\/strong\u003e to moduł tachometru o wysokiej niezawodności i szybkiej reakcji, zaprojektowany specjalnie do ochrony maszyn przed przekroczeniem prędkości w ramach \u003cstrong\u003eSystemu Detekcji Maszyn Serii 3500\u003c\/strong\u003e. Spełnia rygorystyczne wymagania norm American Petroleum Institute (API) 670 i 612 dotyczące ochrony przed przekroczeniem prędkości.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/53\u003c\/strong\u003e Moduł akceptuje sygnały wejściowe z przetworników czujników zbliżeniowych lub czujników magnetycznych do ciągłego monitorowania prędkości obrotowej. Kilka modułów można połączyć w szafie 3500 z redundantnymi zasilaczami, tworząc system logiki głosowania 2 z 2 lub 2 z 3. Moduł zapewnia proporcjonalne wyjścia prądowe dla rejestratorów, buforowane wyjścia przetworników do diagnostyki oraz wbudowane przekaźniki jednobiegunowe dwustykowe (SPDT) do sterowania systemami awaryjnego wyłączania.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObsługuje konfiguracje redundantnego głosowania 2 z 2 lub 2 z 3.\u003c\/li\u003e\n\u003cli\u003eKompatybilny z czujnikami zbliżeniowymi i pasywnymi czujnikami magnetycznymi.\u003c\/li\u003e\n\u003cli\u003eZapewnia kondycjonowanie przetwornika z automatycznym i ręcznym progiem.\u003c\/li\u003e\n\u003cli\u003eZintegrowane przekaźniki jednobiegunowe dwustykowe (SPDT) z możliwością wyboru normalnie załączonego lub normalnie wyłączonego działania.\u003c\/li\u003e\n\u003cli\u003eWskaźniki LED na przednim panelu informujące o stanie modułu, komunikacji, obejściu, trybie testowym i alarmach.\u003c\/li\u003e\n\u003cli\u003eDedykowane złącze koncentryczne na przednim panelu do buforowanego wyjścia przetwornika.\u003c\/li\u003e\n\u003cli\u003eProgramowalne alarmy dla stanów poniżej alertu, powyżej alertu i niebezpieczeństwa (przekroczenie prędkości).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbiny parowe\u003c\/li\u003e\n\u003cli\u003eTurbiny gazowe\u003c\/li\u003e\n\u003cli\u003eTurbosprężarki\u003c\/li\u003e\n\u003cli\u003eWysokoprędkościowe rozprężarki\u003c\/li\u003e\n\u003cli\u003eDuże pompy przemysłowe i wentylatory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eKategoria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eMarka\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eModel\/Numer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eNumer części\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e133388-01 (3500\/53)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eWejście elektryczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eZakres sygnału wejściowego\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e+10,0 V do -24,0 V (ograniczone wewnętrznie)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eImpedancja wejściowa\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e20 k Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eZużycie energii\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eTypowo 8,0 watów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eZasilanie przetwornika\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-24 V DC, maksymalnie 40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eObsługiwane przetworniki\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eCzujniki zbliżeniowe\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e3300 8 mm, 3300 16 mm HTPS, 7200 5 mm, 8 mm, 11 mm, 14 mm, 3300 RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eCzujniki magnetyczne\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003ePasywne czujniki magnetyczne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eKondycjonowanie sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003ePasmo przenoszenia\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1 do 255 zdarzeń na obrót, maks. 99 999 obr.\/min, maksymalne wejście 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eMinimalna częstotliwość wejściowa\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eProximity: 0,0167 Hz (1 obr.\/min przy 1 zdarzeniu\/obrót); czujnik magnetyczny: 3,3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eDokładność obrotów na minutę (RPM)\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e\u0026lt; 100 obr.\/min: ±0,1 obr.\/min; 100 do 10 000 obr.\/min: ±1 obr.\/min; 10 000 do 99 999 obr.\/min: ±0,01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003ePróg automatyczny\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eMinimum 1 wolt od szczytu do szczytu (dla wejść powyżej 0,0167 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003ePróg ręczny\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eUżytkownik może wybrać od +9,9 V DC do -23,9 V DC; minimalnie 500 mV od szczytu do szczytu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eHistereza\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eUżytkownik może wybrać od 0,2 do 2,5 wolta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eWyjścia i rejestrator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eWyjście rejestratora\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e+4 do +20 mA, proporcjonalnie do pełnej skali (obr.\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eZgodność napięciowa\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eZakres 0 do +12 V DC na obciążeniu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003eOpór obciążenia\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e0 do 600 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003eRozdzielczość rejestratora\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e0,3662 uA na bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003eBłąd rejestratora\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e±0,25% w temperaturze pokojowej; ±0,7% w zakresie temperatur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003eCzęstotliwość aktualizacji rejestratora\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003eOkoło 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"22\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"22\"\u003eBuforowana impedancja wyjściowa\u003c\/td\u003e\n\u003ctd data-row=\"22\"\u003e550 Ohm (złącze koncentryczne na przednim panelu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"23\"\u003e\u003cstrong\u003eParametry przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"23\"\u003eTyp przekaźnika\u003c\/td\u003e\n\u003ctd data-row=\"23\"\u003ePrzełącznik jednobiegunowy, dwupozycyjny (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"24\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"24\"\u003eMaksymalna przełączana moc\u003c\/td\u003e\n\u003ctd data-row=\"24\"\u003eDC: 120 W; AC: 600 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"25\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"25\"\u003eMaksymalny przełączany prąd\u003c\/td\u003e\n\u003ctd data-row=\"25\"\u003e5 A (obciążenie rezystancyjne)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"26\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"26\"\u003eMinimalny przełączany prąd\u003c\/td\u003e\n\u003ctd data-row=\"26\"\u003e100 mA przy 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"27\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"27\"\u003eMaksymalne przełączane napięcie\u003c\/td\u003e\n\u003ctd data-row=\"27\"\u003eDC: 30 V DC; AC: 250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"28\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"28\"\u003eŻywotność styków\u003c\/td\u003e\n\u003ctd data-row=\"28\"\u003e100 000 cykli przy 5 A, 24 V DC lub 120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"29\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"29\"\u003eUszczelnienie i ochrona\u003c\/td\u003e\n\u003ctd data-row=\"29\"\u003eUszczelnione epoksydowo; standardowe tłumiki łuku 250 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"30\"\u003e\u003cstrong\u003eAlarmy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"30\"\u003eProgi alarmowe\u003c\/td\u003e\n\u003ctd data-row=\"30\"\u003ePod alertem, ponad alertem, niebezpieczeństwo (przekroczenie prędkości) przez oprogramowanie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"31\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"31\"\u003eOpóźnienia alarmów\u003c\/td\u003e\n\u003ctd data-row=\"31\"\u003eMniej niż 30 ms powyżej 300 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"32\"\u003e\u003cstrong\u003eOgraniczenia środowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"32\"\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd data-row=\"32\"\u003e-30 stopni Celsjusza do +65 stopni Celsjusza (-22 stopni Fahrenheita do +149 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"33\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"33\"\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd data-row=\"33\"\u003e-40 stopni Celsjusza do +85 stopni Celsjusza (-40 stopni Fahrenheita do +185 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"34\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"34\"\u003eWilgotność\u003c\/td\u003e\n\u003ctd data-row=\"34\"\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"35\"\u003e\u003cstrong\u003eCechy fizyczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"35\"\u003eWymiary modułu monitorującego\u003c\/td\u003e\n\u003ctd data-row=\"35\"\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"36\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"36\"\u003eWaga modułu monitorującego\u003c\/td\u003e\n\u003ctd data-row=\"36\"\u003e0,82 kg (1,8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"37\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"37\"\u003eWymiary modułu I\/O\u003c\/td\u003e\n\u003ctd data-row=\"37\"\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"38\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"38\"\u003eWaga modułu I\/O\u003c\/td\u003e\n\u003ctd data-row=\"38\"\u003e0,45 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e EN50081-2 (Emisje promieniowane\/przewodzone EN 55011 Klasa A), EN50082-2 (ESD EN 61000-4-2, promieniowanie ENV 50140, przewodzenie ENV 50141, szybkie impulsy EN 61000-4-4, przepięcia EN 61000-4-5, pole magnetyczne EN 61000-4-8, zaniki napięcia EN 61000-4-11, radiofon ENV 50204)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy niskonapięciowe:\u003c\/strong\u003e EN 61010-1 Wymagania bezpieczeństwa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożonych:\u003c\/strong\u003e CSA\/NRTL\/C, Klasa I, Podział 2, Grupy A, B, C, D, T4 @ Ta = -20 stopni Celsjusza do +65 stopni Celsjusza (Numer certyfikatu: CSA 150268-1002151)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWymagania dotyczące szafy:\u003c\/strong\u003e System wykrywania przekroczenia prędkości musi być zainstalowany w szafie 3500 wyposażonej w redundantne zasilacze, aby zapewnić ciągłość działania.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja logiki głosowania:\u003c\/strong\u003e Dla optymalnej ochrony i zgodności z branżowymi normami bezpieczeństwa, połącz kilka modułów, aby ustanowić schemat głosowania 2 z 3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOkablowanie i ekranowanie:\u003c\/strong\u003e Upewnij się, że kable przetworników są odpowiednio ekranowane i uziemione zgodnie ze standardowymi praktykami Bently Nevada, aby zminimalizować zakłócenia EMI\/RFI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWybór progu przetwornika:\u003c\/strong\u003e Użyj ustawienia Auto Threshold dla standardowych zakresów prędkości powyżej 1 obr.\/min. Dla specjalistycznych zastosowań niskoprędkościowych lub słabych sygnałów skonfiguruj próg ręczny za pomocą oprogramowania.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja przekaźnika:\u003c\/strong\u003e Przed uruchomieniem sprawdź, czy wybór przełącznika sprzętowego dla normalnie załączonego (NE) lub normalnie wyłączonego (ND) odpowiada wymaganiom logicznym systemu awaryjnego wyłączania.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest podstawowa funkcja tego modułu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł zapewnia szybkie, redundantne wykrywanie i ochronę nadprędkości maszyn krytycznych dla przemysłowych urządzeń obrotowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZ jakimi normami API zgodny jest ten moduł?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZaprojektowano go tak, aby spełniał specyficzne wymagania ochrony nadprędkości zgodnie z normami API 670 i 612.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł może obsługiwać sygnały z czujników magnetycznych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, akceptuje sygnały z pasywnych czujników magnetycznych oraz standardowych przetworników zbliżeniowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest maksymalny obsługiwany zakres prędkości przez moduł?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł obsługuje maksymalny zakres pełnej skali do 99 999 obr.\/min oraz częstotliwość wejściową do 20 kHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaka logika głosowania jest zalecana dla systemu nadprędkości?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKonfiguracja systemu głosowania 2 z 3 jest wysoce zalecana dla optymalnej niezawodności i odporności na błędy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest typowy czas reakcji alarmu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOpóźnienie alarmu wynosi mniej niż 30 ms przy częstotliwości wejściowej powyżej 300 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy moduł zapewnia analogowe wyjście trendu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, zapewnia wyjście rejestratora 4–20 mA proporcjonalne do skonfigurowanego zakresu pełnej skali obrotów na minutę.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo się dzieje, gdy wyjście rejestratora ulegnie zwarciu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDziałanie modułu pozostaje całkowicie niezakłócone przez zwarcia na linii wyjścia rejestratora.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie są opcje konfiguracji progów dla wykrywania prędkości?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePosiada automatyczny próg dla sygnałów powyżej 0,0167 Hz oraz programowalny próg ręczny od +9,9 Vdc do -23,9 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakiego typu przekaźniki wewnętrzne są używane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł wykorzystuje przekaźniki jednobiegunowe dwustykowe uszczelnione epoksydowo, wyposażone w standardowe tłumiki łuku 250 Vrms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy stany przekaźników można zmieniać?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKażde przekaźnik można przełączyć, aby działał jako normalnie załączony lub normalnie wyłączony.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo oznacza stałe świecenie diody LED Bypass?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDioda LED Bypass wskazuje, że moduł nadprędkości został przełączony w tryb obejścia, zawieszając aktywne wyjścia alarmowe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł jest bezpieczny do stosowania w strefach zagrożenia wybuchem?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, posiada aprobatę CSA\/NRTL\/C dla środowisk niebezpiecznych Klasy I, Podział 2, Grup A, B, C i D.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520142187,"sku":"3500\/53 133388-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-53-133388-01-overspeed-detection-module-skjqo1gi1mj_01db5316-cd69-4166-964b-efb1e8e829de.jpg?v=1765440146"},{"product_id":"bently-nevada-136711-02-3500-61-rtd-tc-i-o-module","title":"Bently Nevada 136711-02 3500\/61 RTD\/TC I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136711-02\u003c\/strong\u003e is a specialized \u003cstrong\u003eRTD\/TC I\/O Module with Internal Barriers and Internal Terminations\u003c\/strong\u003e developed for the \u003cstrong\u003e3500\/61 16-Channel Temperature Monitor\u003c\/strong\u003e within the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This hardware component serves as the physical interface layer that collects multi-channel temperature signals from field-located transducers. This specific non-isolated variant is engineered with integrated safety barriers, allowing users to configure the termination paths to accept either thermocouple (TC) or resistance temperature detector (RTD) inputs, as well as a flexible combination of both sensor categories simultaneously within the same rack subsystem.\u003c\/p\u003e\n\u003cp\u003eField programming and configuration of channel types are handled through the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e, removing any requirements for physical hardware modifications or field calibration procedures. The module conditions the raw millivolt signals from thermocouples and resistance variances from 3-wire or 4-wire RTDs, feeding structured digital temperature values directly into the main front processor card via the internal backplane bus. Its onboard intrinsic safety design provides a high degree of integration by combining terminal blocks and hazardous area containment barriers into a single space-saving footprint, making the \u003cstrong\u003e3500\/61\u003c\/strong\u003e subsystem ideal for multi-point thermal surveillance of bearings, stator windings, and exhaust paths on heavy rotating assets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHouses physical internal termination blocks paired with integrated safety barriers for hazardous field environments.\u003c\/li\u003e\n\u003cli\u003eNon-isolated universal channel paths support individual configuration for TCs, 3-wire RTDs, or 4-wire RTDs.\u003c\/li\u003e\n\u003cli\u003eEliminates the need for manual component calibration through full integration with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes dedicated high-precision current source networks to satisfy multi-lead RTD measuring circuits.\u003c\/li\u003e\n\u003cli\u003eStructural design optimizes rack footprint by consolidating external terminal boxes and separate intrinsic safety hardware into one rear slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-channel motor and generator stator winding thermal monitoring.\u003c\/li\u003e\n\u003cli\u003eGas turbine exhaust gas temperature (EGT) profile tracking and distribution mapping.\u003c\/li\u003e\n\u003cli\u003eIndustrial bearing temperature monitoring on high-speed pumps, fans, and gearboxes.\u003c\/li\u003e\n\u003cli\u003eBalance-of-plant auxiliary machinery protection across chemical and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e136711-02: RTD\/TC I\/O Module with Internal Barriers and Internal Terminations (Non-Isolated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical \u0026amp; Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Subtype\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated with Internal Safety Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Current Source Value\u003c\/td\u003e\n\u003ctd\u003e925 +\/- 15 uA at 25 degC per transducer (1 supply for 4-wire RTD, 2 supplies for 3-wire RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer \u0026amp; Sensor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple (TC) Capability\u003c\/td\u003e\n\u003ctd\u003eType E, Type J, Type K, Type T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Temperature Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eType E: -100 degC to +1000 degC (-148 degF to +1832 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType J: -18 degC to +760 degC (+0 degF to +1400 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType K: -18 degC to +1370 degC (+0 degF to +2498 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType T: -160 degC to +400 degC (-256 degF to +752 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Temperature Detector (RTD)\u003c\/td\u003e\n\u003ctd\u003e100 Ohm platinum (alpha = 0.00385), 100 Ohm platinum (alpha = 0.00392), 120 Ohm nickel, 10 Ohm copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Measurement Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -200 degC to +850 degC (-328 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -200 degC to +700 degC (-328 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -80 degC to +260 degC (-112 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -100 degC to +260 degC (-148 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges with External Barriers\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -50 degC to +850 degC (-122 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -50 degC to +260 degC (-122 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Conditioning \u0026amp; Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF (except for 10 Ohm Copper RTDs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Isolated External Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-1 degC at 25 degC (+\/-1.8 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolated Internal Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-2 degC at 25 degC (+\/-3.6 degF at 77 degF) \/ +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eNo field calibration required; specified at +25 degC (+77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Dimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Position Requirements\u003c\/td\u003e\n\u003ctd\u003eConsumes 1 full-height rear slot directly behind the main monitor processor card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Barrier Screw Terminals\u003c\/td\u003e\n\u003ctd\u003eDirect physical land connection for raw multi-wire RTD leads and TC field extensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Backplane Bus Plug\u003c\/td\u003e\n\u003ctd\u003eMulti-pin interconnect matrix delivering conditioned sensor data to the 3500 rack bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Install the \u003cstrong\u003e136711-02\u003c\/strong\u003e module directly from the rear side of the 3500 monitoring chassis. It must align perfectly into the slot corresponding to the front-mounted 3500\/61 main processor card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type Matching:\u003c\/strong\u003e Verify through configuration utility software that each channel configuration (thermocouple versus 3-wire or 4-wire RTD) exactly matches the field wire layout connected to the terminal strip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Wire Uniformity:\u003c\/strong\u003e For all 3-wire and 4-wire RTD configurations, employ copper lead wires of uniform gauge and length to guarantee precise lead-resistance compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Control:\u003c\/strong\u003e Run all external field sensor lines through twisted, shielded wire pairs. Land the shields at the designated instrumentation ground terminal provided on the module frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enforcement:\u003c\/strong\u003e Ensure the cabinet installation maintains clean, unobstructed ventilation paths so that the active operating ambient temperature around the internal barrier housing does not exceed 65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 136711-02 component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as the rear terminal and intrinsic safety interface module that routes field RTD and thermocouple signals into a 3500\/61 monitor slot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the designation non-isolated mean for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt indicates that the channels share a common ground reference point, although they remain protected via built-in internal safety barriers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix thermocouples and RTDs on the same I\/O card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the non-isolated channel paths can be customized individually via software to accept a mixed combination of TCs and RTDs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific type of RTD is recommended for standard engineering installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlatinum RTDs featuring an alpha value of 0.00385 are the industrial standard and are highly recommended for optimal precision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs manual field calibration required after replacing this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo manual field calibration is needed because all channel parameter scaling is managed automatically through system configuration software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat constant current value is provided for RTD sensors by this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated current source network delivers 925 +\/- 15 uA at an environmental reference of 25 degC per transducer pathway.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many internal current supplies are engaged when a 4-wire RTD is connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module configuration activates a single current supply line for a 4-wire RTD circuit and two separate supplies for a 3-wire RTD circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the defined operating temperature limitation for this module version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is specified to perform reliably in a continuous ambient temperature environment ranging from 0 degC to +65 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the exact physical dimensions of this rear-mount component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe card measures 241.3 mm in height, 24.4 mm in width, and 163.1 mm in depth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this component contain the primary digital processor card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this part number represents the rear-insert I\/O termination assembly with built-in barriers; the front processor module is supplied separately.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520273259,"sku":"3500\/61 136711-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-136711-02-temperature-module-cnm5uk4ps0a_ea8ec829-abb6-47bf-af49-d0ad661bbb09.jpg?v=1765440149"},{"product_id":"bently-nevada-135799-01-3500-93-display-interface-module","title":"Moduł interfejsu wyświetlacza Bently Nevada 135799-01 3500\/93","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e135799-01 (135799-01)\u003c\/strong\u003e Moduł interfejsu wyświetlacza pełni rolę dedykowanego silnika zbierania danych dla systemu monitoringu Bently Nevada 3500\/93. Zainstalowany z tyłu szafy 3500, sprzęt ten zbiera surowe dane z różnych kart ochrony maszyn i steruje ekranem wizualizacji z przodu. Jest szeroko wykorzystywany w wysoko niezawodnych ciężkich gałęziach przemysłu, takich jak przetwórstwo węglowodorów, platformy wiertnicze na morzu oraz monitorowanie napędu morskiego. Przetwarzając lokalnie zmienne dotyczące drgań strukturalnych, temperatury i prędkości, gwarantuje, że krytyczny stan maszyn pozostaje widoczny dla inżynierów terenowych, co znacznie skraca średni czas naprawy (MTTR) podczas awarii zakładu i minimalizuje całkowity czas przestoju systemu.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e135799-01\u003c\/strong\u003e pełni kluczową rolę łącznika między wewnętrzną magistralą systemu 3500 a zewnętrznym panelem wyświetlacza. Odczytuje cyfrowe pakiety danych z interfejsu danych przejściowych 3500\/22M lub standardowych modułów monitorujących, tłumacząc złożone rejestry modbus lub własne na widoczne ciągi znaków. Układ płytki posiada izolowane ścieżki danych szeregowych, chroniące wewnętrzną logikę przed zewnętrznymi przepięciami elektrycznymi. Obsługuje połączenia punkt-punkt z przednią płytą wyświetlacza za pomocą wysokiej integralności taśmowych kabli, utrzymując ciągłość działania nawet przy silnych zakłóceniach elektromagnetycznych (EMI) typowych dla hal turbin elektrowni.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e135799-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eTyp komponentu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eModuł interfejsu wyświetlacza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003ePort komunikacyjny\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eDedykowany interfejs szeregowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e5,0 W typowo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e-30 do 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-40 do 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003ePowłoka płytki drukowanej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eStandardowa powłoka konformalna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e241 mm x 24 mm x 103 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e0,82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest maksymalna długość kabla obsługiwana między kartą interfejsu 135799-01 a panelem wyświetlacza?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandardowe połączenie taśmowym kablem nieekranowanym nie powinno przekraczać 3 metrów, aby zapobiec tłumieniu sygnału. W przypadku instalacji zdalnych do 30 metrów należy użyć specjalnego kabla ekranowanego z wbudowanymi wzmacniaczami sygnału.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak zdiagnozować błąd \"Display Comm Error\" zarejestrowany na liście zdarzeń systemu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNajpierw sprawdź integralność kabla łączącego moduł interfejsu z panelem wyświetlacza. Jeśli kabel jest prawidłowo podłączony, zweryfikuj, czy pozycja modułu interfejsu odpowiada gnieździe przypisanemu w oprogramowaniu konfiguracyjnym szafy 3500.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ta karta interfejsu wymaga osobnej konfiguracji firmware poza główną szafą?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, \u003cstrong\u003e135799-01\u003c\/strong\u003e dziedziczy aktywną matrycę parametrów operacyjnych z pliku konfiguracyjnego głównej szafy. Przy wymianie uszkodzonej płytki system automatycznie ładuje wymagane ustawienia po ponownym uruchomieniu szafy lub wykryciu nowego sprzętu.\u003c\/p\u003e\n\u003ch3\u003eInstrukcja inżynieryjna i instalacyjna\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eKroki zabezpieczenia kabla przed naprężeniem\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrzymocuj kabel połączeniowy do obudowy szafy za pomocą zintegrowanych opasek nylonowych. Unikaj ostrych zgięć w pobliżu złączy pinów interfejsu; zachowaj minimalny promień gięcia 25 mm, aby zapobiec zmęczeniu przewodów wewnętrznych pod wpływem silnych drgań strukturalnych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtokoły wyrównania pinów\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrzed włożeniem modułu do tylnego gniazda sprawdź piny złącza backplane pod kątem niewyrównania lub zanieczyszczeń. Wyrównaj płytkę poziomo względem prowadnic obudowy i mocno dociśnij, aż mechanizmy blokujące zaskoczą całkowicie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWymagania dotyczące zapobiegania ESD\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnicy terenowi muszą nosić zatwierdzony pasek antystatyczny uziemiony do obudowy szafy podczas instalacji lub obsługi tej karty interfejsu. Bezpośredni kontakt skóry z elementami powierzchniowymi może spowodować ukryte uszkodzenia mikroobwodów.\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520437099,"sku":"3500\/93 135799-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-93-135799-01-display-interface-module-ntqi0yl43bp_50b5fa20-071b-4ec5-aa27-a085b83c71e3.jpg?v=1765440152"},{"product_id":"bently-nevada-176449-08-3500-72m-recip-rod-position-monitor","title":"Bently Nevada 176449-08 3500\/72M Monitor położenia pręta korbowego Recip","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e176449-08 3500\/72M Monitor położenia pręta tłoka\u003c\/strong\u003e to czterokanałowy moduł monitorujący sprężarki tłokowe zaprojektowany do ciągłego pomiaru położenia pręta, opadania pręta i hiperkompresora w platformie ochrony maszyn Bently Nevada 3500. Monitor akceptuje do czterech wejść przetworników zbliżeniowych i kondycjonuje sygnały do analizy dynamicznego przemieszczenia, napięcia szczeliny, kąta wału korbowego oraz amplitudy wektorowej. Moduł obsługuje zastosowania sprężarek tłokowych API 618 w rafineriach, stacjach przetwarzania gazu, zakładach LNG i zakładach petrochemicznych, gdzie wczesne wykrywanie zużycia pręta tłoka, degradacji pierścienia jeźdźca i ruchu krzyżaka jest kluczowe dla ograniczenia nieplanowanych przestojów i uszkodzeń sprężarki.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003eArchitektura 3500\/72M wykorzystuje cztery niezależne kanały monitorujące zgrupowane w programowalne pary kanałów. Każda para może jednocześnie wykonywać oddzielne funkcje położenia pręta lub opadania pręta w tym samym slocie szafy. Monitor komunikuje się z innymi modułami szafy przez system komunikacji szyny 3500 i obsługuje konfigurowalną przez użytkownika logikę alarmów ostrzegawczych i niebezpieczeństwa za pomocą oprogramowania 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003eKondycjonowanie sygnału obejmuje stałe filtrowanie szczyt-szczyt, stałe filtrowanie notch Q, analizę wektorową 1X i 2X oraz przetwarzanie napięcia szczeliny do diagnostyki sprężarek tłokowych. Buforowane wyjścia przetworników na panelu przednim zapewniają bezpośredni dostęp do dynamicznych sygnałów drgań i napięcia szczeliny dla przenośnych analizatorów i pomiarów oscyloskopowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModuł obsługuje następujące tryby pomiaru:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePołożenie pręta\u003c\/li\u003e\n\u003cli\u003eOpadanie pręta\u003c\/li\u003e\n\u003cli\u003eHiperkompresor\u003c\/li\u003e\n\u003cli\u003eŚrednie położenie tłoka\u003c\/li\u003e\n\u003cli\u003eBieżąca szczelina sondy\u003c\/li\u003e\n\u003cli\u003eAmplituda wektorowa 1X i 2X\u003c\/li\u003e\n\u003cli\u003eŚledzenie kąta wału korbowego\u003c\/li\u003e\n\u003cli\u003eAnaliza amplitudy nie 1X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje wydajności\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eSpecyfikacja parametru\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e176449-08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarka\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSeria\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e3500\/72M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eTyp produktu\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eMonitor położenia pręta tłoka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eKanały monitorujące\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eObsługiwane wejścia\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e1 do 4 sygnałów sondy zbliżeniowej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eImpedancja wejściowa\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e10 kOmów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eZużycie energii\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e7,7 W nominalnie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eBuforowana impedancja wyjściowa\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e510 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eNapięcie zasilania przetwornika\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eWskaźniki na panelu przednim\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eOK, TX\/RX, Bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eOdpowiedź częstotliwościowa\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e1 Hz do 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eOdpowiedź filtra szczeliny\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-3 dB przy 0,09 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eZakres prędkości 1X i 2X\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e60 cpm do 2130 cpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eDokładność szczyt-szczyt\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e+\/-0,33% typowo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eMaksymalny błąd pomiaru\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e+\/-1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eDokładność kąta położenia pręta\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e+\/-1 stopień typowo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003eMaksymalny błąd kąta\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e+\/-3 stopnie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003eWymiary\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003eWaga\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e0,91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"22\"\u003ePlatforma szafy\u003c\/td\u003e\n\u003ctd data-row=\"22\"\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"23\"\u003eStandard zastosowania\u003c\/td\u003e\n\u003ctd data-row=\"23\"\u003eAPI 618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"24\"\u003ePochodzenie\u003c\/td\u003e\n\u003ctd data-row=\"24\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePrzewodnik Monitora Pozycji Pręta Recip 3500\/72M\u003c\/h3\u003e\n\u003cp\u003eMonitor Pozycji Pręta Recip 3500\/72M to moduł 4-kanałowy zaprojektowany dla sprężarek tłokowych. Mierzy opadanie pręta, pozycję pręta oraz pozycję tłoka hiper-sprężarki. Opcja \u003ccode\u003e-08\u003c\/code\u003e oznacza \u003cstrong\u003e4-kanałowy Monitor Pozycji Pręta Recip z modułem I\/O z wewnętrznymi zakończeniami\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e🛠️ Sekcja 1: Szczegółowy przewodnik instalacji\u003c\/h4\u003e\n\u003ch5\u003e1. Lista kontrolna przed instalacją\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyłącz zasilanie\u003c\/strong\u003e: Wyłącz całe zasilanie szafy przed wkładaniem lub wyjmowaniem modułów.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOchrona ESD\u003c\/strong\u003e: Noś uziemioną opaskę na nadgarstek, aby zapobiec uszkodzeniom spowodowanym wyładowaniami elektrostatycznymi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZgodność gniazd\u003c\/strong\u003e: Moduł główny 3500\/72M musi być zainstalowany w dowolnym gnieździe monitorującym (gniazda 2 do 15).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDopasowanie I\/O\u003c\/strong\u003e: Moduł I\/O musi być zainstalowany bezpośrednio za modułem głównym z tyłu szafy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e2. Kroki instalacji sprzętu\u003c\/h5\u003e\n\u003cpre data-language=\"plain\"\u003e[Front of Rack]                        [Rear of Rack]\n+--------------------------+           +--------------------------+\n\n|  Moduł główny 3500\/72M    |  \u0026lt;=====\u0026gt;  |  Moduł I\/O 176449-08    |\n+--------------------------+           +--------------------------+\n\u003c\/pre\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eZlokalizuj gniazdo\u003c\/strong\u003e: Wybierz dostępne gniazdo w szafie 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZainstaluj moduł I\/O z tyłu\u003c\/strong\u003e: Wyrównaj moduł I\/O 176449-08 z prowadnicami obudowy z tyłu szafy. Wsuń go, aż złącza całkowicie się połączą. Dokładnie dokręć śruby motylkowe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZainstaluj moduł główny\u003c\/strong\u003e: Wyrównaj moduł główny 3500\/72M z prowadnicami przedniego panelu. Wsuń go mocno, aż osadzi się na płycie tylnej. Dokładnie dokręć śruby motylkowe.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch5\u003e3. Okablowanie w terenie (wewnętrzne zakończenia)\u003c\/h5\u003e\n\u003cp\u003e176449-08 używa wewnętrznych bloków zakończeniowych. Podłącz przewody czujnika Proximitor bezpośrednio do listw zaciskowych w stylu euro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandardowe okablowanie dla każdego kanału (kanał 1 do kanału 4):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVT (Napięcie)\u003c\/strong\u003e: Podłącz do Proximitora \"VT\" lub pinu A (sygnał wyjściowy).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOM (Wspólny)\u003c\/strong\u003e: Podłącz do Proximitora \"COM\" lub pinu B (wspólny układ).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-24V (Zasilanie)\u003c\/strong\u003e: Podłącz do Proximitora \"-24V\" lub pinu C (wejście zasilania).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSHLD (Ekran)\u003c\/strong\u003e: Podłącz ekran kabla tutaj. Zakończ ekran \u003cem\u003etylko\u003c\/em\u003e na końcu monitora.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e4. Konfiguracja oprogramowania (Oprogramowanie Konfiguracji Szafy 3500)\u003c\/h5\u003e\n\u003col\u003e\n\u003cli\u003eOtwórz \u003cstrong\u003eOprogramowanie Konfiguracji Szafy 3500\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDodaj \u003cstrong\u003e3500\/72M\u003c\/strong\u003e do gniazda, w którym został fizycznie zainstalowany.\u003c\/li\u003e\n\u003cli\u003eWybierz typ kanału \u003cstrong\u003ePozycja Pręta Recip\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eSkonfiguruj \u003cstrong\u003eorientację sondy\u003c\/strong\u003e (zwykle pionową lub pod kątem prostym względem orientacji pręta).\u003c\/li\u003e\n\u003cli\u003eWprowadź \u003cstrong\u003eczynnik skali\u003c\/strong\u003e (zwykle 7,87 V\/mm lub 200 mV\/mil dla standardowych systemów Proximitor).\u003c\/li\u003e\n\u003cli\u003eUstaw \u003cstrong\u003eprogi alarmowe\u003c\/strong\u003e (limity ostrzegawcze i niebezpieczne) zgodnie ze specyfikacjami OEM twojej sprężarki.\u003c\/li\u003e\n\u003cli\u003ePobierz konfigurację do szafy za pomocą interfejsu danych przejściowych 3500\/22M (TDI).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e❓ Sekcja 2: Najczęściej zadawane pytania (FAQ)\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Co oznacza przyrostek „-08” w numerze części 176449-08?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Oznacza to \u003cstrong\u003e4-kanałowy monitor pozycji pręta ruchu posuwisto-zwrotnego z modułem I\/O z wewnętrznymi zakończeniami\u003c\/strong\u003e. Oznacza to, że okablowanie polowe podłącza się bezpośrednio do zacisków śrubowych z tyłu modułu I\/O bez potrzeby stosowania zewnętrznego bloku zakończeniowego.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Czy mogę wymieniać moduł 3500\/72M na gorąco?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: \u003cstrong\u003eTak\u003c\/strong\u003e, system 3500 obsługuje hot-swap („gorące wstawianie”) głównych modułów monitorujących. Należy jednak bardzo uważać, aby nie zwarć sąsiednich pinów, a wymiana tylnego modułu I\/O wymaga całkowitego wyłączenia zasilania szafy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Dlaczego do tego monitora potrzebne jest koło wieloimpulsowe (Multi-Event Wheel) lub Keyphasor wału korbowego?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Pomiar pozycji pręta ruchu posuwisto-zwrotnego wymaga znajomości dokładnej pozycji tłoka w cyklu ruchu. Model 3500\/72M używa sygnału Keyphasor do wyzwalania okien pomiarowych przy określonych kątach wału korbowego (np. górny martwy punkt lub dolny martwy punkt).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Co oznaczają statusy diod LED na przednim panelu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiody LED OK\u003c\/strong\u003e: Zielone światło oznacza prawidłowe działanie modułu. Migające oznacza inicjalizację lub tryb konfiguracji. Brak światła oznacza usterkę sprzętową lub brak zasilania.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiody LED TX\/RX\u003c\/strong\u003e: Migające bursztynowe światło oznacza aktywną komunikację z modułem 3500\/22M TDI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiody LED obejścia\u003c\/strong\u003e: Stałe bursztynowe światło oznacza, że jeden lub więcej kanałów jest obecnie obejściem (alarmy są tłumione).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Jak obsługiwać pomiary spadku pręta w porównaniu do standardowej wibracji promieniowej?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Spadek pręta mierzy średnie przesunięcie fizycznej pozycji pręta tłoka spowodowane zużyciem pierścienia jeźdźca. Standardowa wibracja filtruje składową stałą (DC). Model 3500\/72M przetwarza zmianę napięcia DC względem skalibrowanego punktu odniesienia, aby określić zużycie grubości pierścienia jeźdźca.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520535403,"sku":"3500\/72M 176449-08","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-72m-176449-08-recip-rod-position-monitor-ixnkabghioe_34baeb22-d024-4556-8211-15f663eddd28.jpg?v=1765440153"},{"product_id":"bently-nevada-3500-45-140072-04-position-monitor-module","title":"Moduł monitorowania pozycji Bently Nevada 3500\/45 140072-04","description":"\u003ch2\u003eModuł monitorowania pozycji Bently Nevada 140072-04 3500\/45\u003c\/h2\u003e\n\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/45\u003c\/strong\u003e, skonfigurowany z zapasowym numerem części karty \u003cstrong\u003e140072-04\u003c\/strong\u003e, to wysokoprecyzyjny, czterokanałowy sprzęt zaprojektowany do ciągłego zbierania danych z sond zbliżeniowych, przetworników położenia obrotowego (RPT), liniowych przetworników różnicowych prądu stałego (DC LVDT), liniowych przetworników różnicowych prądu zmiennego (AC LVDT) oraz potencjometrów obrotowych. Działając jako architektoniczna bariera ochronna, instrument przetwarza sygnały wejściowe z czujników na określone metryki proporcjonalne i nieustannie porównuje te wartości inżynieryjne z wysoce konfigurowalnymi, zarządzanymi programowo progami alarmowymi. Dynamicznie konfigurowany w dopasowanych parach za pomocą oprogramowania 3500 Rack Configuration Software, jednocześnie spełnia parametry bezpieczeństwa operacyjnego w różnych trybach monitorowania, w tym położenia osiowego wału, różnicowego rozszerzania, rozszerzania obudowy i pozycjonowania zaworu sterującego. Kondycjonowane pętle prądowe rejestratora przypisują dedykowaną ścieżkę wyjściową +4 do +20 mA dla poszczególnych kanałów pomiarowych, aby zapewnić bezpośredni stan pracy maszyn urządzeniom sterującym.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCzterokanałowa konstrukcja operacyjna wspierająca do dwóch jednoczesnych zachowań śledzenia na moduł w parach bloków kanałów.\u003c\/li\u003e\n\u003cli\u003eKompleksowe kondycjonowanie sygnału akceptujące sondy prądów wirowych, urządzenia RPT, LVDT prądu stałego i zmiennego oraz potencjometry obrotowe.\u003c\/li\u003e\n\u003cli\u003eLogika oprogramowania układowego obsługująca standardowe, niestandardowe i podwójne pomiary różnicowego rozszerzania z rampą.\u003c\/li\u003e\n\u003cli\u003eSpecjalistyczne bezpośrednie filtrowanie dolnoprzepustowe połączone z dedykowanymi elementami tłumiącymi do izolacji rzeczywistego fizycznego przemieszczenia mechanicznego.\u003c\/li\u003e\n\u003cli\u003eIndywidualne, zabezpieczone przed zwarciem, buforowane łącza koncentryczne na panelu przednim dostarczające czyste, nieprzetworzone sygnały z czujników.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObserwacja pozycji osi turbiny parowej o dużej mocy oraz automatyczne monitorowanie różnicowego rozszerzania obudowy.\u003c\/li\u003e\n\u003cli\u003eŚledzenie położenia zaworu regulatora i weryfikacja rozszerzalności obudowy w elektrowni wodnej.\u003c\/li\u003e\n\u003cli\u003eŚledzenie przemieszczenia wirnika rozprężarki gazu w zakładzie produkcyjnym oraz mechaniczne zabezpieczenia blokujące.\u003c\/li\u003e\n\u003cli\u003eAnaliza liniowego ruchu i wyrównania skoku głównego zaworu pary w kotle przemysłowym o dużej wytrzymałości.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/45-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModuł monitorowania pozycji\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Typ modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O pozycji z wewnętrznymi zakończeniami (Proximitor, RPT, DC LVDT) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O pozycji z zewnętrznymi zakończeniami (Proximitor, RPT, DC LVDT) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eDyskretny moduł I\/O TMR pozycji z zewnętrznymi zakończeniami (Proximitor, DC LVDT) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O TMR pozycji z interfejsem magistrali i zewnętrznymi zakończeniami (Proximitor) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O pozycji AC LVDT z zakończeniami wewnętrznymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O pozycji AC LVDT z zakończeniami zewnętrznymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O pozycji potencjometru obrotowego z zakończeniami wewnętrznymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O pozycji potencjometru obrotowego z zakończeniami zewnętrznymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpcja zatwierdzenia agencji B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęści zamienne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e140072-04\u003c\/td\u003e\n\u003ctd\u003eModuł monitora pozycji 3500\/45 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/45 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140072-04 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKanały wejścia sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 4 konfiguracji sygnału \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa DC LVDT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa Proximitor \/ RPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa AC LVDT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e137 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja potencjometru obrotowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie mocy (RPT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 7,7 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie mocy (AC LVDT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 8,5 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie mocy (potencjometr)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 5,6 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjście zasilania Proximitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjście zasilania DC LVDT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+15 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNapięcie sygnału napędu AC LVDT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,3 V rms, fala sinusoidalna 3400 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNapięcie napędu potencjometru\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-12,38 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wyjścia pętli rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 do +20 mA DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZgodność napięcia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do +12 V DC na zewnętrznej pętli \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny opór obciążenia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWydajność rozdzielczości analogowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,3662 µA na bit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęstotliwość odświeżania danych analogowych\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms lub mniej \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOdpowiedź bezpośredniego filtra dolnoprzepustowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-3 dB przy 1,2 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOdpowiedź filtra zaporowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-3 dB przy 0,41 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePodstawowa dokładność pomiaru statycznego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach ±0,33% w całej skali, maksymalnie ±1% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePodstawowa dokładność rozszerzenia rampy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach ±1,0% pełnej skali \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres opóźnienia alarmu ostrzegawczego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund z konfiguracją co 1 sekundę \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres opóźnienia alarmu niebezpieczeństwa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,1 sekundy lub 1 do 60 sekund w krokach co 1 sekundę \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 stopni Celsjusza do +65 stopni Celsjusza (-22 stopni Fahrenheita do +150 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 stopni Celsjusza do +85 stopni Celsjusza (-40 stopni Fahrenheita do +185 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wilgotności roboczej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% wilgotności względnej bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga głównej karty monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg (2,0 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu interfejsu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,45 kg (1,0 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary głównej karty monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary karty interfejsu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,2 mm x 24,4 mm x 99,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMacierz przydziału szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 przedni slot obudowy i 1 tylny slot obudowy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eZacisk \/ Pin złącza\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF CH1 \/ CH2 \/ CH3 \/ CH4 BNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorty przednie czujnika surowe, nieuwarunkowane, chronione przed zwarciem \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePRZETWORNIKI (ZASILANIE \/ COM \/ SIG \/ OSŁONA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElementy połączeń przewodów pola tylnej krawędzi przypisane do wejścia czujnika \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWYJŚCIA REJESTRATORA (REC1 do REC4 \/ COM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUwarunkowane połączenia przewodów pętli nadajnika +4 do +20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWYJŚCIA REJESTRATORA (OSŁONA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowany przewód uziemiający wspólny dla osłon pętli \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlok zaciskowy RO INHB \/ RET\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZewnętrzne połączenie pętli nadpisania logiki dla blokad bezpieczeństwa \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKontrola zakłóceń: Zakończ osłony instrumentów czujnika pola wyraźnie na przypisanych pinach złącza SHLD na płycie tylnej, aby zablokować sprzężenie pola elektrostatycznego.\u003c\/li\u003e\n\u003cli\u003eOgraniczenia interfejsu: Pamiętaj, że konfiguracje pozycji zaworu sterującego są całkowicie niedostępne podczas wdrażania tego sprzętu w architekturach szaf z potrójną redundancją modułową (TMR).\u003c\/li\u003e\n\u003cli\u003eUwzględnienie obudowy: Upewnij się, że funkcje rozszerzalności obudowy są ściśle przypisane do pozycji kanału 3 lub kanału 4 na module, ponieważ kanały 1 i 2 nie posiadają specjalistycznych parametrów oprogramowania wymaganych dla tego trybu.\u003c\/li\u003e\n\u003cli\u003eZabezpieczenie środowiskowe: Umieść główną płytę czołową równo z wytycznymi koszyka kart 3500, aby zapewnić ciągłą wentylację obudowy przez sąsiednie podzespoły.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNormy ochrony elektrycznej: Wymagania bezpieczeństwa środowiskowego EN 61010-1 dla sprzętu pomiarowego i laboratoryjnego.\u003c\/li\u003e\n\u003cli\u003eLimity emisji elektromagnetycznej: Zgodność z EN50081-2 dla emisji przemysłowych, certyfikowana według warunków klasy A EN 55011.\u003c\/li\u003e\n\u003cli\u003eOdporność elektromagnetyczna: EN50082-2 wysoka odporność przemysłowa obejmująca limity wyładowań elektrostatycznych EN 61000-4-2.\u003c\/li\u003e\n\u003cli\u003eOceny stref zagrożenia: Certyfikat CSA \/ NRTL \/ C dla przemysłowych środowisk klasy I, dywizji 2, grup A, B, C i D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne i zakupowe\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy ten konkretny moduł może przetwarzać częstotliwości wejściowe z czujników drgań o wysokiej prędkości obrotowej?\u003c\/strong\u003e O: Nie, ten moduł pozycyjny jest specjalnie zaprojektowany z wolno działającą siecią śledzącą dolnoprzepustową o punkcie -3 dB na 1,2 Hz, co czyni go nieodpowiednim do pomiaru dynamicznych częstotliwości drgań obudowy maszyn o wysokiej częstotliwości.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jakie zachowanie występuje na buforowanych portach koncentrycznych na panelu przednim podczas korzystania z czujnika DC LVDT?\u003c\/strong\u003e O: Surowe profile napięcia wyjściowego kierowane z kanałów 3 i 4 doświadczają wewnętrznej celowej korekty napięcia o wartość -10 V DC, aby utrzymać zakres przetwarzania sygnału.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy nieoczekiwana usterka okablowania lub zwarcie w pętli rejestratora prądu wpłynie na wyzwalanie przekaźników bezpieczeństwa monitora?\u003c\/strong\u003e O: Nie, pętle prądowe wyjściowe są wyposażone w kompleksową izolację elektryczną, co zapewnia, że zwarcia pętli polowych na trasach rejestratora nie naruszają podstawowego przetwarzania logiki modułu ani generowania alarmów przekroczenia limitu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jakie oprogramowanie musi być spełnione, aby wdrożyć urządzenie RPT do śledzenia pozycji zaworu?\u003c\/strong\u003e O: System musi działać na oprogramowaniu 3500 Rack Configuration w wersji 3.00 lub wyższej, aby poprawnie odblokować niezbędne krzywe konwersji czujników i parametry skalowania dla przetworników pozycji obrotowej.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy karta 140072-04 wymaga dodatkowego wejścia Keyphasor do obliczania surowej różnicowej rozszerzalności obudowy?\u003c\/strong\u003e O: Nie, instrument oblicza precyzyjne parametry fizycznego przemieszczenia całkowicie na podstawie surowych statycznych poziomów napięcia stałego dostarczanych przez czujniki polowe, eliminując jakiekolwiek operacyjne uzależnienie od zewnętrznych odniesień czasowych.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520600939,"sku":"3500\/45 140072-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-45-140072-04-position-monitor-module-xwqvjbqml1t_f2aeac00-fa3d-40f3-a5bf-8da6176829c1.jpg?v=1765440155"},{"product_id":"bently-nevada-3500-42-proximitor®-seismic-monitor-module","title":"Moduł monitorujący sejsmiczny Bently Nevada 3500\/42 Proximitor®","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/42\u003c\/strong\u003e to czterokanałowa karta ochrony maszyn zaprojektowana dla systemu ochrony maszyn \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e, zapewniająca ciągłe monitorowanie drgań i przemieszczeń maszyn. Ten moduł przetwarzania monitorujący na bieżąco przyjmuje sygnały elektryczne z czujników zbliżeniowych, prędkości lub akcelerometrów. \u003cstrong\u003e3500\/42\u003c\/strong\u003e filtruje i skaluje surowe sygnały przetworników do standardowych zmiennych inżynierskich, oceniając parametry zdrowia operacyjnego w czasie rzeczywistym, takie jak drgania promieniowe wału, pozycja osiowego nacisku, ekscentryczność, przyspieszenie, prędkość i rozszerzalność różnicowa.\u003c\/p\u003e\n\u003cp\u003ePracując w ramach szafy 3500, moduł porównuje każdy aktywny kanał pomiarowy z zaprogramowanymi progami alarmowymi i niebezpieczeństwa skonfigurowanymi sprzętowo. Gdy parametry przekraczają normalne wartości, karta natychmiast generuje sygnały alarmowe przez tylną szynę szafy, wywołując automatyczne blokady i polecenia wyłączenia urządzeń, niezależnie od oprogramowania stacji roboczej. Układ urządzenia obejmuje indywidualne konfiguracje par kanałów oraz niezależne pętle wyjścia rejestratora proporcjonalnego do integracji z systemami zarządzania zakładem i zewnętrznymi rejestratorami danych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCzterokanałowa matryca przetwarzania czujników akceptująca jednoczesne sygnały z czujników zbliżeniowych, prędkości lub przyspieszenia.\u003c\/li\u003e\n\u003cli\u003eKompleksowe programowanie funkcjonalne wspierające drgania promieniowe, pozycję nacisku, ekscentryczność i rozszerzalność różnicową.\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne kanały wejściowe ułożone w pary do wykonywania niezależnego kondycjonowania sygnału i procedur śledzenia.\u003c\/li\u003e\n\u003cli\u003eBuforowane wyjścia przetworników na panelu przednim zapewniające natychmiastowy dostęp koncentryczny dla zewnętrznych dynamicznych analizatorów diagnostycznych.\u003c\/li\u003e\n\u003cli\u003eRedundantne połączenie tylnej szyny 3500 utrzymujące spójne porównania parametrów kanałów i trasowanie blokad bezpieczeństwa.\u003c\/li\u003e\n\u003cli\u003eWyraźne wskaźniki diagnostyczne na przedniej płycie zapewniające natychmiastową widoczność statusu modułu OK, aktywności magistrali TX\/RX oraz trybów obejścia.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCiągłe monitorowanie drgań promieniowych i awarii łożysk olejowych w krytycznych turbosprężarkach zakładu.\u003c\/li\u003e\n\u003cli\u003eBezpośrednie pozycjonowanie osiowego nacisku wału i pętle przemieszczenia wirnika wewnątrz ciężkich turbin parowych do wytwarzania energii.\u003c\/li\u003e\n\u003cli\u003eWysokoprecyzyjne mechaniczne przyspieszenie obudowy i krzyżowe weryfikacje drgań prędkości strukturalnej na dużych modułach silników pomocniczych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł Proximitor \/ monitora sejsmicznego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo 7,7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePojemność sygnału wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObsługuje 1 do 4 wejść przetworników zbliżeniowych, prędkości lub przyspieszenia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa (standardowe I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ (wejścia Proximitor i przyspieszeniowe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność bezpośrednia i szczelinowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo w granicach ±0,33% pełnej skali, maksymalnie ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRozdzielczość wyjścia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,3662 µA na bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZgodność napięcia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do +12 Vdc na obciążeniu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres rezystancji obciążenia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do 600 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTłumienie filtra Bias\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-3 dB przy 0,01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTłumienie filtra Not OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-3 dB przy 2400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWydajność częstotliwości odświeżania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms lub mniej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu głównego (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMasa netto modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOgraniczenia wilgotności\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eElement interfejsu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrzednie złącza koncentryczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCztery dedykowane buforowane porty wyjściowe przetwornika do weryfikacji dynamicznych przebiegów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCiągły zielony wskaźnik pokazujący prawidłowy stan monitora i modułu I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMigający wskaźnik śledzący wymianę komunikatów w czasie rzeczywistym na magistrali szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda BYPASS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStały wskaźnik sygnalizujący, że parametr kanału lub sekwencja alarmowa jest wyciszona\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTablica wielopinowa tylnej płyty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStałe piny złączy tworzące połączenia zasilania, wejścia i sterowania alarmem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWkładanie do szafy:\u003c\/strong\u003e Wsuń obudowę modułu prosto w przezroczyste prowadnice po prawej stronie modułu interfejsu szafy. Dociśnij mocno, aż zestaw zacisków całkowicie wejdzie do złączy tylnej płyty, następnie zabezpiecz przedni panel śrubami motylkowymi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOkablowanie pola przetwornika:\u003c\/strong\u003e Prowadź sygnały czujnika przez dedykowane, izolowane przewody pomiarowe. Końcówki podłącz do tylnego zespołu zacisków I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUziemienie elektrostatyczne:\u003c\/strong\u003e Podczas rozpakowywania lub modyfikacji zachowuj ciągłe połączenie z zatwierdzonym opaską antystatyczną na nadgarstek, aby chronić wewnętrzne układy analogowe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZarządzanie ciągłością ekranu:\u003c\/strong\u003e Podłącz przewody odprowadzające ekran kabla wejściowego do dedykowanych zacisków ekranu na bloku I\/O, pozostawiając koniec czujnika nieuziemiony, aby wyeliminować standardowe zakłócenia pętli masy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e3500\/42 vs. 3500\/42M: Kluczowe różnice i przewodnik wyboru\u003c\/h3\u003e\n\u003cp\u003ePodczas zarządzania ochroną maszyn legacy, sieciami legacy lub pozyskiwania części zamiennych do systemu \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e, zrozumienie technicznych granic między standardowym monitorem \u003cstrong\u003e3500\/42\u003c\/strong\u003e a ulepszonym monitorem \u003cstrong\u003e3500\/42M\u003c\/strong\u003e (Multimode) Proximitor\/Seismic jest kluczowe dla kompatybilności zakładu.\u003c\/p\u003e\n\u003ch4\u003ePorównanie architektury\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja \/ Specyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMonitor legacy 3500\/42\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eUlepszony monitor 3500\/42M\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneracja sprzętu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWczesna seria produkcyjna bazowa\u003c\/td\u003e\n\u003ctd\u003eNowsza generacja serii Multimode (obecny standard OEM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramowanie kanałów\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFunkcjonalnie ograniczone dla par kanałów za pomocą fizycznych zworek na płycie\u003c\/td\u003e\n\u003ctd\u003eW pełni konfigurowalne programowo dla każdego kanału za pomocą oprogramowania 3500 Rack Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMieszane wejścia czujników\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOgraniczona elastyczność; kanały muszą odpowiadać określonym grupom zworek\u003c\/td\u003e\n\u003ctd\u003eWysoka elastyczność; umożliwia jednoczesne łączenie czujników zbliżeniowych i sejsmicznych na jednej karcie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZaawansowane przetwarzanie sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardowe monitorowanie drgań, położenia osi i prędkości obudowy\u003c\/td\u003e\n\u003ctd\u003eObsługuje zaawansowane algorytmy, w tym REBAM®, Shaft Absolute i Circular Acceptance Region\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKompatybilne tylne karty I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140471-01 (wewnętrzny) \/ 140482-01 (zewnętrzny)\u003c\/td\u003e\n\u003ctd\u003e128229-01 (wewnętrzny) \/ 128240-01 (zewnętrzny)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eZasady wyboru i kompatybilności wstecznej\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpośrednia wymiana legacy:\u003c\/strong\u003e Jeśli w Twojej obecnej szafie znajduje się oryginalna główna karta monitorująca \u003cstrong\u003e3500\/42\u003c\/strong\u003e, która uległa degradacji sprzętowej, nowsza \u003cstrong\u003e3500\/42M\u003c\/strong\u003e może pełnić funkcję kompletnego zamiennika. Jest w pełni kompatybilna wstecz z magistralą komunikacyjną tylnej płyty szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eObowiązkowa zasada „Dopasowanej pary”:\u003c\/strong\u003e \u003cstrong\u003eNie można\u003c\/strong\u003e podłączyć przedniej karty monitorującej \u003cstrong\u003e3500\/42M\u003c\/strong\u003e do starszego tylnego modułu I\/O \u003cstrong\u003e3500\/42\u003c\/strong\u003e (i odwrotnie). Wewnętrzne układy ścieżek i elektryczne połączenia pinów są różne. Jeśli zdecydujesz się na modernizację starszego gniazda do serii 42M, musisz zakupić i wymienić \u003cstrong\u003ezarówno przednią kartę monitorującą, jak i tylny moduł I\/O jako dopasowany zestaw\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePonowne wdrożenie konfiguracji:\u003c\/strong\u003e Podczas wymiany starego zestawu sprzętowego 3500\/42 na 3500\/42M technicy terenowi muszą połączyć się za pomocą oprogramowania 3500 Rack Configuration, zmodyfikować typ definicji wyznaczonego gniazda na „3500\/42M”, odwzorować oryginalne metryki przetwornika i wykonać świeże pobranie logiki, aby aktywować gniazdo.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666531938667,"sku":"3500\/42","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42-proximitor-seismic-monitor-0uvaaynfrl1_ba527237-f7d2-4c33-9470-6b25869a7b65.jpg?v=1765440372"},{"product_id":"bently-nevada-3500-50m-tachometer-module","title":"Moduł tachometru Bently Nevada 3500\/50M","description":"\u003cp style=\"color: #2d3748;\"\u003e\u003cstrong\u003eBently Nevada 3500\/50M\u003c\/strong\u003e to 2-kanałowy instrument zaprojektowany do ochrony maszyn, który przetwarza sygnały elektryczne z sond zbliżeniowych lub czujników magnetycznych w celu oceny krytycznych parametrów wału. Ten moduł oparty na mikroprocesorze ciągle śledzi absolutną prędkość obrotową wału, przyspieszenie wirnika lub kierunek fazy operacyjnej, automatycznie weryfikując cyfrowe pomiary względem programowalnych wewnętrznych nastaw, aby wywołać statusy alarmowe i niebezpieczeństwa w sieci interfejsu szafy 3500.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eKluczowe cechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eZintegrowana synchronizacja fazowa:\u003c\/strong\u003e Konfigurowalna do kondycjonowania sygnałów źródłowych przetwornika i dostarczania zweryfikowanych impulsów Keyphasor bezpośrednio przez pasywną płytę tylnią, eliminując techniczną konieczność stosowania niezależnej karty kontrolera Keyphasor.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRejestry operacyjne Peak Hold:\u003c\/strong\u003e Wewnętrzne matryce pamięci autonomicznie rejestrują i przechowują szczytową prędkość obrotową, ekstremalne parametry prędkości wstecznej oraz absolutne skumulowane liczniki obrotów wstecznych.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eKompatybilność z dwoma przetwornikami:\u003c\/strong\u003e Bezpośredni sprzęt wielomodeowy spełnia standardy impedancji dla standardowych systemów zbliżeniowych prądów wirowych oraz samogenerujących czujników magnetycznych.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedykowane sprzętowe strażniki:\u003c\/strong\u003e Logika obwodu na pokładzie stale aktualizuje niezależne wskaźniki stanu OK, TX\/RX i Bypass na panelu przednim, zapewniając natychmiastowe potwierdzenie stanu fizycznego.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRegulowane opóźnienia alarmów:\u003c\/strong\u003e Obsługa dyskretnej konfiguracji polowej dla struktur interwałów Alarmu 1 (od 1 do 60 sekund z krokiem 1 sekundy) oraz mechanizmów Alarmu 2 (od 1 do 60 sekund z krokiem 0,1 sekundy).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDiagnostyka turbin:\u003c\/strong\u003e Ciągłe monitorowanie prędkości i ocena przyspieszenia w przemysłowych turbinach parowych, ciężkich turbinach gazowych oraz procesowych sprężarkach odśrodkowych.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eOgraniczanie obrotów wstecznych:\u003c\/strong\u003e Wykrywanie w czasie rzeczywistym warunków cofania procesu w systemach pompowania cieczy o dużej wydajności oraz w wielostopniowych turbinach gazowych.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfilowanie rozruchu i hamowania:\u003c\/strong\u003e Monitorowanie krytycznych przyspieszeń wirnika podczas operacji przejściowych przez krytyczne prędkości maszyny.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBlokada sprzęgła rozruchowego:\u003c\/strong\u003e Bezpieczne pętle potwierdzające zerową prędkość, umożliwiające systemom automatyki autoryzację automatycznego załączania sprzęgła rozruchowego.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eKod opcji\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eSzczegóły parametrów wyboru\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003eZespół bazowy 3500\/50-AA-BB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eAA - 01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł I\/O z zakończeniami wewnętrznymi\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eAA - 02\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł I\/O z zakończeniami zewnętrznymi\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eAA - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł I\/O z barierami wewnętrznymi i zakończeniami wewnętrznymi\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eBB - 00\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZatwierdzenie do stref zagrożenia: Brak\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eBB - 01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZatwierdzenie do stref zagrożenia: CNRTLus (Klasa I, Dywizja 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eBB - 02\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZatwierdzenie do stref zagrożonych wybuchem: ATEX\/IECEx\/CSA (klasa I, strefa 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eKategoria parametru\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eWartość inżynieryjna\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePojemność wejścia sygnału\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAkceptuje do 2 sygnałów z przetworników\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres napięcia wejściowego\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+10,0 V do -24,0 V (ograniczone wewnętrznie)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres impedancji wejściowej\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e20 kOhm (standard), 40 Ohm (TMR), 7,15 kOhm (wewnętrzna bariera)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZużycie energii\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTypowe zużycie mocy 5,8 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWyjście zasilania przetwornika\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC, maksymalny prąd 40 mA na kanał\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWyjścia analogowego rejestratora\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+4 do +20 mA proporcjonalnie; 0 do +12 V DC przy obciążeniu 0 do 600 Ohm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaksymalny zakres pełnej skali\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e99 999 obr.\/min\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaksymalna częstotliwość śledzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e20 kHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMinimalna częstotliwość śledzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eProximity: 0,0167 Hz (1 obr.\/min przy 1 zdarzeniu\/obrót); czujniki magnetyczne: 3,3 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDokładność pomiaru obrotów na minutę (RPM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePoniżej 100 obr.\/min: plus\/minus 0,1 obr.\/min; od 100 do 10 000 obr.\/min: plus\/minus 1 obr.\/min; powyżej 10 000 obr.\/min: plus\/minus 0,01% rzeczywistej prędkości\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWymiary głównej płytki\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWymiary standardowej płytki I\/O\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga głównej płytki\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0,82 kg (1,8 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga standardowej płytki I\/O\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0,20 kg (0,44 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres temperatur pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 stopni Celsjusza do +65 stopni Celsjusza (klasyfikacja termiczna T4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (firma Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStany Zjednoczone\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1,48 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWymiary opakowania (obliczone)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e315 mm x 295 mm x 90 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e To urządzenie jest przeznaczone wyłącznie do monitorowania stanu maszyn i logicznego sygnalizowania ostrzeżeń. NIE używaj modułu 3500\/50M jako samodzielnego urządzenia ani jako wbudowanego elementu w podstawowych pętlach awaryjnego wyłączania nadprędkościowego. Nie posiada on odpowiedniej szybkości reakcji ani redundancji konstrukcyjnej potrzebnej do definitywnej kontroli awaryjnego zatrzymania silnika lub turbiny. Odłącz wszystkie główne kanały zasilania szafy przed fizyczną pracą z komponentami tylnej płyty.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eZałóż funkcjonalną opaskę przeciwelektrostatyczną (ESD) podłączoną do metalowej ramy obudowy przed obsługą głównych płytek przetwarzających, aby zapobiec uszkodzeniom warstw półprzewodnikowych.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWyrównaj i zabezpiecz główny moduł tachometru w dowolnym pełnowysokim przednim gnieździe w strukturze szafy 3500, prowadząc ścieżki prowadzące aż do całkowitego zablokowania modułu.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWsuń dopasowany moduł I\/O tachometru do identycznego gniazda z tyłu szyny kart. Dokładnie dokręć śruby mocujące do tylnej płyty montażowej.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePodłącz kable czujnika pola bezpośrednio do tylnych bloków zaciskowych I\/O. Jeśli konfigurujesz alerty niskiej prędkości, aktualizacje zerowej prędkości lub protokoły wykrywania kierunku wstecznego, unikaj czujników magnetycznych, ponieważ ich niskonapięciowy sygnał poniżej progów docelowych pogorszy dokładność pomiaru prędkości.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666541441387,"sku":"3500\/50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-50-discrete-internal-barrier-i-o-module-nfgwlk4n5ui_05382e1f-085d-4aa4-9808-0c89cdcff61b.jpg?v=1765440472"},{"product_id":"bently-nevada-3500-32-4-channel-relay-module","title":"Moduł przekaźnikowy Bently Nevada 3500\/32 4-kanałowy","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModel \u003cstrong\u003e3500\/32\u003c\/strong\u003e to komponent pełnowymiarowy zaprojektowany dla systemu ochrony maszyn \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e, oferujący cztery w pełni programowalne wyjścia przekaźnikowe. Moduł ten można umieścić w dowolnym slocie po prawej stronie modułu interfejsu szafy, aby sterować krytyczną logiką alarmową i wyłączania maszyn. Każdy przekaźnik wykorzystuje wysoce konfigurowalną logikę sterowania alarmem, którą można programować za pomocą kombinacji AND i OR alertów i zagrożeń z dowolnego kanału monitorującego w szafie. Ta zdecentralizowana konfiguracja logiki działa za pomocą oprogramowania 3500 Rack Configuration Software, realizując działania ochronne natychmiastowo, niezależnie od kontroli oprogramowania nadrzędnego.\u003c\/p\u003e\n\u003cp\u003eSprzęt wykorzystuje wysoce odporną konfigurację przekaźników składającą się z dwóch przekaźników jednobiegunowych, dwupozycyjnych (SPDT) ułożonych w konfigurację dwubiegunową, dwupozycyjną (DPDT) dla każdego z czterech kanałów. Każdy kanał posiada przełącznik umożliwiający wybór trybu Normalnie Wyłączony lub Normalnie Załączony, co pozwala na elastyczne dostosowanie do bezpiecznych układów przemysłowych. Wbudowane diody LED umożliwiają operatorom terenowym dynamiczne, szybkie monitorowanie stanu magistrali komunikacyjnych i warunków alarmowych poszczególnych przekaźników.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCztery niezależne wyjścia przekaźnikowe oferujące w pełni konfigurowalne, specyficzne dla kanału ścieżki logiki głosowania.\u003c\/li\u003e\n\u003cli\u003eProgramowanie logiki sterowania alarmem wspierające rozbudowane kombinacje parametrów AND\/OR na wejściach całej szafy.\u003c\/li\u003e\n\u003cli\u003ePodwójne przekaźniki SPDT połączone w solidną konfigurację DPDT dla każdego niezależnego kanału.\u003c\/li\u003e\n\u003cli\u003ePrzekaźniki uszczelnione epoksydowo zintegrowane ze standardowymi tłumikami łuku 250 Vrms dla trwałego bezpieczeństwa styków.\u003c\/li\u003e\n\u003cli\u003eWbudowany przełącznik umożliwiający bezpośrednie przełączanie między stanami Normalnie Załączony i Normalnie Wyłączony.\u003c\/li\u003e\n\u003cli\u003ePrzejrzysta diagnostyka LED na przednim panelu wskazująca stan modułu OK, komunikację (TX\/RX) oraz status alarmu poszczególnych kanałów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatyczne rejestrowanie awaryjnych wyłączeń i pętle zatrzymania maszyn w krytycznych turbinach przemysłowych.\u003c\/li\u003e\n\u003cli\u003eSystemy bezpieczeństwa zakładu z blokadami oraz sieci sterujące wizualnymi\/dźwiękowymi sygnalizatorami alarmowymi.\u003c\/li\u003e\n\u003cli\u003eRozproszone konfiguracje logiki głosowania dla matryc ochrony bilansu instalacji w elektrowniach i rafineriach ropy naftowej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReferencja zamówienia produktu\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGłówne oznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32 (Moduł przekaźnikowy 4-kanałowy) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpcja modułu wyjściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01 (Moduł I\/O przekaźnikowy 4-kanałowy) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00 (Brak) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-01 (CSA \/ NRTL \/ C) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł przekaźnikowy 4-kanałowy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo 6 watów \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKonfiguracja typu przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDwa przekaźniki SPDT połączone w konfiguracji DPDT na kanał \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUszczelnienie środowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUszczelnienie epoksydowe \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOcena tłumika łuku\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms (standardowo zainstalowany) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrwałość styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 000 cykli przy 5 A, 24 Vdc lub 120 Vac \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaksymalne napięcie przełączane\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003edc: 30 Vdc \/ ac: 250 Vac \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny prąd przełączany\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalny prąd przełączany\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA przy 5 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMoc przełączana\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003edc: 120 W \/ ac: 600 VA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu głównego (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 242 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,7 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 99,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,4 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatur pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatur przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOgraniczenia wilgotności\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania przestrzeni w szafie (główne)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe przednie gniazdo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania przestrzeni w szafie (I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe tylne gniazdo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePołączenie zaciskowe\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunkt podłączenia styku normalnie zamkniętego na kanał przekaźnika \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eARM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunkt podłączenia styku ramienia\/wspólnego na kanał przekaźnika \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunkt podłączenia styku normalnie otwartego na kanał przekaźnika \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTRYB PRZEKAŹNIKA (NDE\/NE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzełączniki suwakowe sprzętowe kontrolujące stany załączenia poszczególnych kanałów \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmieszczenie modułu:\u003c\/strong\u003e Wsuń główną kartę bezpośrednio do dowolnego dostępnego pełnowymiarowego przedniego gniazda po prawej stronie modułu interfejsu szafy. Włóż odpowiadający moduł I\/O do pasującego tylnego gniazda obudowy. Zamocuj wszystkie śruby płyty czołowej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWybór trybu przekaźnika:\u003c\/strong\u003e Ustaw dedykowane przełączniki sprzętowe na panelu I\/O przed włączeniem modułu, aby ustawić tryb Normalnie Rozłączony (NDE) lub Normalnie Załączony (NE) zgodnie z projektem pętli.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracje okablowania:\u003c\/strong\u003e Podłącz wszystkie obwody urządzeń zewnętrznych do tylnego bloku zacisków śrubowych. Zapewnij prawidłowe podłączenie segmentów NC, ARM i NO, aby zapobiec błędom sygnalizacji mechanicznej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUziemienie elektrostatyczne:\u003c\/strong\u003e Używaj jednorazowej opaski uziemiającej na nadgarstek podczas rozpakowywania lub modyfikacji parametrów wewnętrznego obwodu, aby chronić elementy płytki przed wyładowaniami elektrostatycznymi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy oznakowania CE:\u003c\/strong\u003e Zgodność ze standardami dyrektywy EMC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmisje promieniowane i przewodzone:\u003c\/strong\u003e EN 55011, Klasa A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard odporności i podatności:\u003c\/strong\u003e IEC 61000-6-2, w tym ESD (61000-4-2), promieniowanie (ENV 50140), przewodzenie (ENV 50141), EFT (EN 61000-4-4), przepięcia (EN 61000-4-5) oraz pole magnetyczne (61000-4-8).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożonych:\u003c\/strong\u003e Certyfikat CSA\/NRTL\/C dla Klasy I, Podział 2, Grupy A, B, C, D (T4 @Ta = -20°C do +65°C; Numer certyfikatu: CSA 150268-1002151).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666544587115,"sku":"3500\/32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-32-4-channel-relay-module-bkzt4nr51v5_04f81160-46a1-4bce-8a94-c976310465bd.jpg?v=1765440504"},{"product_id":"bently-nevada-3500-15-114m5329-01-high-voltage-dc-power-supply","title":"Zasilacz wysokiego napięcia stałego Bently Nevada 3500\/15 114M5329-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 114M5329-01\u003c\/strong\u003e to moduł zasilania prądem stałym o wysokim napięciu w formacie półwysokości, zaprojektowany do integracji z systemem ochrony maszyn serii 3500. Ten moduł zasilania dostarcza regulowane napięcie stałe do wspólnych szyn zasilających, zapewniając stabilne napięcia robocze na sąsiednich kartach monitorujących, diagnostycznych i komunikacyjnych zamontowanych w ramie szafy. Działa w połączeniu z dedykowanym modułem wejściowym zasilania prądem stałym o wysokim napięciu (PIM) i umożliwia dowolne łączenie z alternatywnym źródłem zasilania prądem przemiennym, co pozwala na uzyskanie spersonalizowanych podwójnych ścieżek zasilania. W konfiguracji systemu z podwójnym zasilaniem \u003cstrong\u003e114M5329-01\u003c\/strong\u003e umożliwia dynamiczne wyrównywanie sprzętowe, wspierając ciągłą ochronę maszyn w dużych zakładach przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObudowa półwysokości zoptymalizowana do montażu w lewym slocie zasilania\u003c\/li\u003e\n\u003cli\u003ePrawdziwa zdolność podwójnego zasilania online zapewniająca niezawodne automatyczne przełączanie awaryjne\u003c\/li\u003e\n\u003cli\u003eBezpośrednie fizyczne oddzielenie od krytycznych ścieżek bezpieczeństwa maszyn, zapobiegające przerwom technicznym\u003c\/li\u003e\n\u003cli\u003eW pełni wymienny na gorąco montaż umożliwiający prace konserwacyjne bez wyłączania systemów\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSzafy ochrony maszyn wymagające stabilnego zasilania z baterii stacji prądu stałego\u003c\/li\u003e\n\u003cli\u003ePlatformy monitorowania prędkości ciężkich sprężarek przemysłowych, turbin i pomp pomocniczych\u003c\/li\u003e\n\u003cli\u003eKrytyczna infrastruktura maszynowa w rafineriach ropy, zakładach petrochemicznych i elektrowniach\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114M5329-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZasilacz prądu stałego o wysokim napięciu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNapięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 do 140 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary (Wysokość x Szerokość x Głębokość)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział slotów\u003c\/strong\u003e: Wsuń moduł półwysokości wyłącznie do wyznaczonych slotów zasilania po lewej stronie obudowy szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja redundancji\u003c\/strong\u003e: Zainstaluj główny moduł zasilania w dolnym slocie, a zapasowy moduł zasilania w górnym slocie, aby utrzymać automatyczny układ awaryjny.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKompatybilność sprzętowa\u003c\/strong\u003e: Upewnij się, że zasilacz prądu stałego o wysokim napięciu jest sparowany wyłącznie z nowoczesnym modułem wejściowym zasilania prądem stałym o wysokim napięciu (PIM); jest całkowicie niekompatybilny ze starszym sprzętem PIM serii 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperacje wymiany na gorąco\u003c\/strong\u003e: Przed usunięciem lub wymianą modułu upewnij się, że co najmniej jedno zapasowe źródło zasilania pozostaje całkowicie aktywne i operacyjne, aby uniknąć przerwy w zasilaniu obudowy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666571981163,"sku":"3500\/15 114M5329-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-114m5329-01-high-voltage-dc-power-supply-jzh5fdotlq5_dbdf0a66-6f36-40c7-91ed-6ceecfd8e2ba.jpg?v=1765440857"},{"product_id":"bently-nevada-3500-15-04-04-00-114m5330-01-power-supply","title":"Zasilacz Bently Nevada 3500\/15-04-04-00 114M5330-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/15-04-04-00\u003c\/strong\u003e o numerze części \u003cstrong\u003e114M5330-01\u003c\/strong\u003e to moduł zasilania o połowie wysokości, zaprojektowany do dostarczania regulowanego napięcia stałego (DC) przez tylną płytę szyny systemu ochrony maszyn serii 3500. Ten moduł \u003cstrong\u003e3500\/15-04-04-00 114M5330-01\u003c\/strong\u003e działa w zakresie napięcia wejściowego od 20 do 30 V DC, przekształcając surowe źródło energii w wysoce stabilne zasilanie wymagane przez sąsiednie monitory, karty komunikacyjne i procesory przekaźnikowe. Zaprojektowany do montażu w dedykowanych gniazdach po lewej stronie głównej obudowy, system ten obsługuje zarówno konfiguracje samodzielne, jak i podwójnie redundantne. W konfiguracji podwójnej dolne gniazdo sprzętowe działa jako zasilanie podstawowe, podczas gdy górny moduł pozostaje w trybie hot-standby, wykonując natychmiastowe przełączenie w przypadku awarii obwodu nadrzędnego lub wyłączenia głównego modułu.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObsługa układu podwójnej redundancji z płynnym przejściem online z modułów podstawowych na zapasowe.\u003c\/li\u003e\n\u003cli\u003eArchitektura instalacji hot-swappable umożliwia wyjmowanie pojedynczych kart bez destabilizacji działania systemu.\u003c\/li\u003e\n\u003cli\u003eRegulowany obwód wyjściowy chroni płyty przetwarzające przed nagłymi skokami napięcia.\u003c\/li\u003e\n\u003cli\u003eWysoka zdolność prądowa pozwala zasilać w pełni wyposażoną szafę instrumentacyjną serii 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDystrybucja zasilania systemu do śledzenia zasobów maszyn i systemów drgań obudowy.\u003c\/li\u003e\n\u003cli\u003eKonfiguracje monitorowania maszyn zgodne z API 670.\u003c\/li\u003e\n\u003cli\u003eCiągłe zasilanie instrumentów dla turbin parowych, turbin gazowych i dużych sprężarek przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod sufiksu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeria produktu: Moduł zasilania 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTyp zasilacza (Górne gniazdo): Legacy niskonapięciowe DC (20 do 30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTyp zasilacza (Dolne gniazdo): Legacy niskonapięciowe DC (20 do 30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZatwierdzenie agencji: Brak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15-04-04-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114M5330-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy niskonapięciowy moduł zasilania DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 do 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrąd pełnej szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,0 A (maksymalnie)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 in x 2,0 in x 9,9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział gniazd:\u003c\/strong\u003e Montuj ten moduł o połowie wysokości wyłącznie w przydzielonych gniazdach po lewej stronie obudowy serii 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja redundantna:\u003c\/strong\u003e Umieść podstawowy zasilacz w dolnym gnieździe, a zapasowy w górnym, aby skonfigurować ciągłą redundancję zasilania zasobów.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyrównanie mechaniczne:\u003c\/strong\u003e Wsuń moduł prosto wzdłuż prowadnic obudowy, aż tylne złącze wielopinowe pewnie połączy się z siecią dystrybucji na płycie tylnej. Dokładnie dokręć śruby mocujące na przednim panelu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDobór PIM:\u003c\/strong\u003e Łącz ten niskonapięciowy komponent wyłącznie z odpowiadającym Legacy niskonapięciowym modułem wejściowym zasilania DC (PIM). Nie łącz ani nie mieszaj komponentów legacy z nowszymi uniwersalnymi modułami AC lub alternatywnymi modułami DC PIM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZarządzanie termiczne:\u003c\/strong\u003e Zachowaj wolne drogi przepływu powietrza wokół obudowy, aby zapewnić, że temperatura otoczenia nie przekroczy projektowego limitu +65°C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666619298155,"sku":"3500\/15-04-04 114M5330-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-04-04-114m5330-01-power-supply-5k35pxxvdye_c27aac77-1ccb-4ed2-961f-aed70c79263b.jpg?v=1765444237"},{"product_id":"bently-nevada-3500-05-01-01-00-00-00-system-chassis-rack","title":"Obudowa systemowa Bently Nevada 3500\/05-01-01-00-00-00 Rack","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModel \u003cstrong\u003e3500\/05-01-01-00-00-00\u003c\/strong\u003e to pełnowymiarowa, 19-calowa \u003cstrong\u003eszafa systemowa\u003c\/strong\u003e wyprodukowana przez \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (firma Baker Hughes), zaprojektowana jako podstawowa rama strukturalna dla \u003cstrong\u003eSystemu Ochrony Maszyn Serii 3500\u003c\/strong\u003e. Sprzęt ten służy jako fizyczna obudowa i centralny węzeł magistrali, mieszczący wszystkie podstawowe monitory drgań maszyn 3500, interfejsy danych przejściowych oraz zasilacze systemowe. Zapewnia niezbędną szybką magistralę komunikacyjną umożliwiającą bezproblemową wymianę danych między poszczególnymi gniazdami, jednocześnie dostarczając wysoce filtrowaną wewnętrzną sieć zasilania do każdego modułu sprzętowego.\u003c\/p\u003e\n\u003cp\u003eDokładny kod układu sprzętowego \u003cstrong\u003e3500\/05-01-01-00-00-00\u003c\/strong\u003e szczegółowo opisuje \u003cstrong\u003epełnowymiarową, 19-calową ramę strukturalną zawierającą 14 dostępnych gniazd instrumentacyjnych\u003c\/strong\u003e (z wyłączeniem dedykowanych pozycji modułów zasilania i interfejsu szafy po lewej stronie). Posiada opcję konstrukcji \u003cstrong\u003ePanel Mount\u003c\/strong\u003e, co oznacza, że jest zoptymalizowany do bezpośredniego montażu w niestandardowych prostokątnych wycięciach w drzwiach szaf lub panelach kontrolnych, gdzie jest solidnie mocowany za pomocą dołączonych mocnych zacisków mechanicznych. Wszystkie podłączone do wejścia\/wyjścia pętle czujników, kable przetworników i moduły I\/O z tyłu są w pełni dostępne bezpośrednio od tyłu konstrukcji panelu. Ten model nie posiada specjalnych zatwierdzeń agencji ds. zagrożeń i jest standardowym sprzętem produkcyjnym.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentralna, szybka magistrala komunikacyjna umożliwiająca przetwarzanie w czasie rzeczywistym między kartami ochrony.\u003c\/li\u003e\n\u003cli\u003ePełnowymiarowa architektura instrumentacji 19-calowej oferująca 14 oddzielnych, konfigurowalnych gniazd modułowych.\u003c\/li\u003e\n\u003cli\u003eProjekt do montażu na panelu z użyciem mocnych zacisków montażowych do płaskiej integracji na frontach paneli.\u003c\/li\u003e\n\u003cli\u003eKonfiguracja z dostępem od tyłu zapewniająca możliwość okablowania pętli czujników i kart I\/O bez otwierania przedniej obudowy.\u003c\/li\u003e\n\u003cli\u003eSztywna, przemysłowa konstrukcja metalowa tłumiąca wysokoczęstotliwościowe drgania otoczenia i chroniąca przed zakłóceniami magnetycznymi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGłówna lokalna szafa sprzętowa zawierająca karty ochrony maszyn dla dużych turbin parowych i gazowych.\u003c\/li\u003e\n\u003cli\u003eCentralny, zakładowy węzeł monitorowania bezpieczeństwa i predykcyjnej konserwacji na torach sprężania o wysokich wibracjach.\u003c\/li\u003e\n\u003cli\u003eObudowy do wielokanałowego zarządzania wibracjami stosowane wewnątrz surowych pomieszczeń kontrolnych rafinerii ropy naftowej i gazu lub petrochemicznych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRozbicie ciągu opcji\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eGniazdo kodu opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWybrana wartość opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły techniczne\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/05\u003c\/td\u003e\n\u003ctd\u003eSeria produktów szaf systemowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Rozmiar szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eSzafa 19-calowa (14 użytecznych gniazd modułów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Opcje montażu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eOpcja montażu panelowego, format pełnowymiarowej szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Opcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eBrak (standardowa klasyfikacja strefy bezpieczeństwa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Opcja zarezerwowana\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eBrak (konfiguracja fabryczna bazowa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Zgodność europejska\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eBrak (konfiguracja standardowa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes \/ GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eID wariantu części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/05-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKategoria produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSzafa systemu monitorowania stanu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŁączna liczba dostępnych gniazd\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 gniazd dla standardowych monitorów oraz 2 dedykowane pozycje po lewej dla zasilania\/RIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfil montażu fizycznego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegracja wycięcia panelu na równi z dostępem I\/O od tyłu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCałkowita szerokość ramy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e482,60 mm (standardowy układ 19 cali)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCałkowita wysokość ramy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265,94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCałkowita głębokość ramy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e349,25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŚrednia waga komponentu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOkoło 13,6 kg (30 funtów) do 20,4 kg (45 funtów) bez obciążenia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał obudowy bazowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrube stopy aluminium i konstrukcyjne blachy metalowe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCel odniesienia uziemienia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane miedziane zaciski uziemiające umieszczone na tylnej siatce obudowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterfejs konstrukcyjny\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWewnętrzna magistrala szyny\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGęsta matryca pinów rozprowadzająca wewnętrzne zasilanie DC i logikę sterującą między gniazdami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrzestrzeń panelu I\/O z tyłu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOtwarta architektura gniazd przyjmujących wsuwane zewnętrzne bloki zakończeń czujników polowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZacisk uziemiający obudowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMocny miedziany bolec łączący ramę szafy z konstrukcyjnym uziemieniem ochronnym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWymiary wycięcia panelu:\u003c\/strong\u003e Przygotuj czyste, prostokątne wycięcie panelu o dokładnych wymiarach określonych w dokumentacji Bently Nevada. Zapewnij odpowiednią głębokość za powierzchnią panelu dla przestrzeni modułów I\/O oraz promieni gięcia kabli.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZałączanie systemu zaciskowego:\u003c\/strong\u003e Włóż zespół szafy od frontu wycięcia panelu. Od wewnątrz lub z tyłu zaczep dostarczone zaciski mocujące na boczne prowadnice obudowy i równomiernie je dokręć, aż uszczelka przedniej powierzchni szczelnie przylegnie do panelu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZasady dotyczące dedykowanych gniazd użytkowych:\u003c\/strong\u003e Pamiętaj, że skrajnie lewe gniazda są przeznaczone wyłącznie dla modułów zasilania (takich jak 3500\/15) oraz modułu interfejsu szafy (3500\/22M). Standardowe monitory drgań nie mogą być wkładane do tych gniazd użytkowych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePołączenie uziemienia obudowy:\u003c\/strong\u003e Podłącz przewód uziemiający z grubego miedzianego drutu od głównego bolca uziemiającego obudowy do podstawowej sieci uziemienia elektrycznego w panelu sterowniczym, aby zablokować szumy elektryczne.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666732937579,"sku":"3500\/05-01-01-00-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-05-01-01-00-00-00-system-chassis-rack-s1mgpi1jvdj_ce783f00-cf9c-408f-86ad-916cfcd4868a.jpg?v=1765446714"},{"product_id":"bently-nevada-3500-05-01-02-00-00-00-3500-system-rack","title":"Bently Nevada 3500\/05-01-02-00-00-00 Szafa systemu 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/05-01-02-00-00-00\u003c\/strong\u003e pełni funkcję pełnowymiarowej szafy systemowej 19-calowej zaprojektowanej przez Bently Nevada dla Systemu Monitorowania Stanu Maszyn 3500. Ta rama sprzętowa zapewnia miejsca montażowe dla wszystkich modułów monitorujących serii 3500 oraz jednostek zasilających, umożliwiając szybką komunikację przez szkielet oraz czysty rozdział zasilania między sąsiednimi komponentami. Ta konkretna konfiguracja modelu oferuje 14 dostępnych slotów na moduły i wykorzystuje format montażu w szafie 19-calowej EIA, co pozwala na bezpieczne przymocowanie do standardowych szyn sprzętowych.\u003c\/p\u003e\n\u003cp\u003eZaprojektowany w celu optymalizacji efektywności układu panelu, \u003cstrong\u003e3500\/05-01-02-00-00-00\u003c\/strong\u003e umieszcza wszystkie zakończenia okablowania polowego oraz moduły wejścia\/wyjścia (I\/O) z tyłu konstrukcji obudowy dla łatwego dostępu podczas konserwacji. Projekt wymaga, aby główne zasilacze i moduł interfejsu szafy zajmowały skrajne lewe pozycje slotów, pozostawiając pozostałe sloty na niestandardowe kombinacje operacyjne modułów monitorujących, ochronnych i wyświetlających.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWysokogęstościowy układ obudowy:\u003c\/strong\u003e Zawiera pełnowymiarową infrastrukturę szafy 19-calowej EIA z 14 dedykowanymi slotami na moduły monitorujące i sterujące.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardowy interfejs szynowy:\u003c\/strong\u003e Wykorzystuje format montażu w szafie opcji 02, umożliwiający bezpośrednią integrację z konwencjonalnymi przemysłowymi obudowami 19-calowymi EIA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDostępność portów I\/O z tyłu:\u003c\/strong\u003e Skonfigurowany tak, aby odsłonić wszystkie krytyczne ścieżki okablowania oraz moduły wejścia\/wyjścia na tylnej ściance dla ułatwionej obsługi serwisowej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZintegrowany szkielet komunikacyjny:\u003c\/strong\u003e Umożliwia komunikację między sąsiednimi modułami przez szybkie magistrale wbudowane bezpośrednio w tylny panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZorganizowany rozdział zasilania:\u003c\/strong\u003e Zaprojektowany do bezpiecznego umieszczenia podstawowych modułów zasilania systemu na skrajnym lewym brzegu, aby regulować i wyrównywać linie zasilania w całej obudowie.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMontaż obudowy dla pętli sprzętu monitorującego stan maszyn serii 3500 \u003c\/li\u003e\n\u003cli\u003eCentralne umieszczenie szafy dla modułów drgań, położenia i prędkości \u003c\/li\u003e\n\u003cli\u003eStandardowa szafa 19-calowa stosowana w pomieszczeniach kontrolnych rafinerii, petrochemii i elektrowni \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis \/ Przypisanie parametrów\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpis produktu: Szafa systemowa \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRozmiar szafy: Szafa 19-calowa (14 slotów modułów) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja montażu: Montaż w szafie, pełnowymiarowa szafa (montaż do szafy EIA 19-calowej) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: Brak \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZarezerwowane: Brak \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zgodności europejskiej: Brak \/ Pominięte \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eElement\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis \/ wartość\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitorowanie stanu maszyn serii 3500 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary obudowy (szerokość)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e482,60 mm (19,000 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary obudowy (wysokość)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265,94 mm (10,470 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary obudowy (głębokość)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246,38 mm (9,700 cala) \/ 349,25 mm (13,750 cala) głębokość podstawy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŁączna liczba dostępnych slotów\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 slotów (z wyłączeniem zasilacza i przypisań interfejsu) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForma montażu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKonfiguracja montażu w szafie EIA 19-calowej \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagana wersja oprogramowania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWarianty mini-rack wymagają wersji 2.70 lub nowszej oprogramowania 3500\/01 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer dokumentu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e141525 Wyd. K \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOgraniczenie położenia modułu:\u003c\/strong\u003e Upewnij się, że zasilacze systemu podstawowego oraz główny moduł interfejsu szafy są zamocowane wyłącznie w najbardziej lewych pozycjach ramy obudowy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMocowanie na szynie EIA:\u003c\/strong\u003e Wyrównaj uchwyty montażowe obudowy z standardowymi szynami EIA 19-calowymi i zabezpiecz za pomocą śrub konstrukcyjnych, aby wytrzymać drgania maszyn.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDostosowanie głębokości bariery:\u003c\/strong\u003e Jeśli planujesz instalację wewnętrznych barier w zespole, dostosuj wymiary przestrzeni, aby uwzględnić zwiększoną bazową głębokość 422,91 mm (16,650 cala).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWymagania dotyczące przestrzeni z tyłu:\u003c\/strong\u003e Zapewnij wystarczającą wolną przestrzeń za obudową montażową, aby umożliwić swobodne zakończenie przewodów polowych i ręczne podłączenie kart I\/O.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Zgodne z częścią 15 przepisów FCC dotyczącą zakłóceń sygnałów przemysłowych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy EMC:\u003c\/strong\u003e Oceniane według EN 61000-6-2 (odporność przemysłowa) oraz EN 61000-6-4 (emisje przemysłowe).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Certyfikowane zgodnie z Dyrektywą Niskonapięciową 2014\/35\/UE oraz normą EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia morskie:\u003c\/strong\u003e Formalnie kwalifikowane zgodnie z zasadami American Bureau of Shipping (ABS) oraz wytycznymi klasyfikacyjnymi DNV GL.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666735526251,"sku":"3500\/05-01-02-00-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-05-01-02-00-00-00-system-rack-yd0fglpupxk_6feaee9c-ffe9-478c-8ce9-d527a2f032d3.jpg?v=1765446782"},{"product_id":"bently-nevada-3500-05-01-02-00-00-01-system-rack","title":"Stelaż systemowy Bently Nevada 3500\/05-01-02-00-00-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModel \u003cstrong\u003e3500\/05-01-02-00-00-01\u003c\/strong\u003e to pełnowymiarowy, 19-calowy \u003cstrong\u003estojak systemowy\u003c\/strong\u003e wyprodukowany przez \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (firma Baker Hughes), zaprojektowany jako podstawowa struktura nośna dla \u003cstrong\u003eSystemu Ochrony Maszyn Serii 3500\u003c\/strong\u003e. Ten sprzęt służy jako fizyczna obudowa i szybka magistrala, która mieści wszystkie podstawowe monitory drgań maszyn serii 3500, interfejsy danych przejściowych oraz zasilacze systemowe. Zintegrowana cyfrowa magistrala umożliwia płynną wymianę danych sterujących w czasie rzeczywistym między poszczególnymi slotami instrumentacyjnymi, jednocześnie dostarczając wysoce filtrowaną wewnętrzną sieć zasilania do każdego modułu wsuwanego.\u003c\/p\u003e\n\u003cp\u003eDokładny kod konfiguracji zamówienia \u003cstrong\u003e3500\/05-01-02-00-00-01\u003c\/strong\u003e opisuje \u003cstrong\u003epełnowymiarową, 19-calową konstrukcję szkieletową zawierającą 14 dostępnych slotów instrumentacyjnych\u003c\/strong\u003e (z wyłączeniem dedykowanych pozycji modułów zasilania i interfejsu stojaka po lewej stronie). Posiada opcję konstrukcji \u003cstrong\u003emontażu na przegrodzie\u003c\/strong\u003e, co oznacza, że jest zaprojektowany do montażu bezpośrednio na ścianie, panelu przegrody strukturalnej lub w niestandardowej obudowie tam, gdzie brak tradycyjnych otwartych szyn przekaźnikowych EIA 19-calowych. Wszystkie podstawowe zakończenia wejść\/wyjść, pętle przetworników i moduły I\/O z tyłu są w pełni dostępne bezpośrednio z panelu przedniego w tej opcji układu. Model ten posiada certyfikaty \u003cstrong\u003ezgodności europejskiej (CE)\u003c\/strong\u003e i jest standardowym sprzętem produkcyjnym.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentralna, szybka magistrala komunikacyjna umożliwiająca interakcję przetwarzania w czasie rzeczywistym między kartami ochrony.\u003c\/li\u003e\n\u003cli\u003ePełnowymiarowa architektura instrumentacji 19-calowej oferująca 14 oddzielnych, konfigurowalnych slotów modułowych.\u003c\/li\u003e\n\u003cli\u003eKonstrukcja montażu na przegrodzie umożliwiająca instalację na płaskiej, pionowej powierzchni tam, gdzie brak tradycyjnych szyn szaf 19-calowych.\u003c\/li\u003e\n\u003cli\u003eMożliwość dostępu do wejść\/wyjść od frontu, zapewniająca pełne okablowanie pętli czujników polowych i zakończeń zewnętrznych od przodu.\u003c\/li\u003e\n\u003cli\u003eSztywna, przemysłowa konstrukcja metalowa tłumiąca wysokoczęstotliwościowe drgania otoczenia i chroniąca przed zakłóceniami magnetycznymi.\u003c\/li\u003e\n\u003cli\u003ePełna zgodność europejska (CE) – certyfikat fabryczny zapewniający niezawodne wdrożenie w europejskich zakładach przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGłówny lokalny stojak sprzętowy zawierający karty ochrony maszyn dla dużych turbin parowych i gazowych.\u003c\/li\u003e\n\u003cli\u003eCentralny, zakładowy węzeł monitorowania bezpieczeństwa i predykcyjnej konserwacji na torach sprężarkowych o wysokich drganiach.\u003c\/li\u003e\n\u003cli\u003eObudowy montowane na przegrodzie stosowane wewnątrz surowych pomieszczeń kontrolnych rafinerii ropy naftowej i gazu lub petrochemicznych, gdzie dostęp od tyłu jest zablokowany.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRozbicie opcji ciągu znaków\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji gniazda\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWybrana wartość opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły techniczne\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/05\u003c\/td\u003e\n\u003ctd\u003eSeria produktów szaf systemowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Rozmiar szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eSzafa 19-calowa (14 użytecznych gniazd modułów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Opcje montażu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-02\u003c\/td\u003e\n\u003ctd\u003eOpcja montażu na przegrodzie, format pełnowymiarowej szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Opcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eBrak (standardowa klasyfikacja strefy bezpieczeństwa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Opcja zarezerwowana\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eBrak (konfiguracja bazowa fabryczna)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Zgodność europejska\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eZatwierdzenie CE (etykieta certyfikacji zgodności europejskiej w zestawie)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eID wariantu części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/05-01-02-00-00-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKategoria produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSzafa systemu monitorowania stanu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŁączna liczba dostępnych gniazd\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 gniazd na standardowe monitory oraz 2 dedykowane lewe pozycje dla zasilania\/RIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfil montażu fizycznego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegracja powierzchni przegrody z dostępem do okablowania I\/O z przodu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCałkowita szerokość ramy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e482,60 mm (standardowy rozstaw 19 cali)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCałkowita wysokość ramy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265,94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCałkowita głębokość ramy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e349,25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŚrednia waga komponentu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOkoło 13,6 kg (30 funtów) do 20,4 kg (45 funtów) pustej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał obudowy bazowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrube stopy aluminium i blachy konstrukcyjne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCel odniesienia uziemienia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane miedziane zaciski uziemiające na siatce obudowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterfejs konstrukcyjny\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzydział funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWewnętrzna magistrala szyny\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGęsty układ pinów rozprowadzający wewnętrzne zasilanie DC i logikę sterującą między gniazdami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrzestrzeń panelu I\/O z przodu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKonfiguracja przegrody z przesuwanymi złączami zewnętrznych czujników polowych montowanymi od przodu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZacisk uziemiający obudowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMocny miedziany bolec łączący ramę szafy z konstrukcyjnym uziemieniem ochronnym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzygotowanie powierzchni przegrody:\u003c\/strong\u003e Sprawdź, czy ściana lub panel konstrukcyjny może nieprzerwanie utrzymać ciężar w pełni załadowanej szafy 3500 (do 20,4 kg lub 45 funtów). Wstępnie wywierć otwory montażowe zgodnie z dokładnym rozmieszczeniem szablonu podanym w instrukcjach instalacji Bently Nevada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzestrzeń dostępu z przodu:\u003c\/strong\u003e Ponieważ jest to obudowa montowana na przegrodzie (-02), zarówno główne karty monitorujące, jak i odpowiadające im moduły I\/O montuje się od przodu. Zachowaj minimalną przestrzeń 250 mm przed frontem szafy na promienie gięcia kabli, korytka kablowe i demontaż modułów.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZasady dotyczące dedykowanych gniazd użytkowych:\u003c\/strong\u003e Pamiętaj, że skrajnie lewe gniazda są przeznaczone wyłącznie dla modułów zasilania (takich jak 3500\/15) oraz modułu interfejsu szafy (3500\/22M). Standardowe monitory maszyn nie mogą być instalowane w tych gniazdach użytkowych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePołączenie uziemienia obudowy:\u003c\/strong\u003e Podłącz przewód uziemiający z grubego miedzianego drutu od głównego bolca uziemiającego obudowy do podstawowej sieci uziemienia elektrycznego obudowy panelu sterowania, aby zablokować zakłócenia elektryczne i zapewnić stabilność przyrządów.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666764362091,"sku":"3500\/05-01-02-00-00-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-05-01-02-00-00-01-system-rack-5ktnha1utrv_b8f01905-49ca-426f-9031-897972de17f9.jpg?v=1765447193"},{"product_id":"bently-nevada-3500-92-communication-gateway-modules","title":"Moduły bramki komunikacyjnej Bently Nevada 3500\/92","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł bramki komunikacyjnej 3500\/92 służy do przesyłania danych monitorujących z systemu ochrony maszyn 3500 do zewnętrznych platform PLC, DCS, SCADA i HMI za pomocą interfejsów komunikacji Ethernet i szeregowej. Obsługuje komunikację Modbus TCP i Modbus RTU dla wartości pomiarowych szafy, statusów alarmów oraz monitorowania stanu systemu.\u003c\/p\u003e\n\u003cp\u003eModuł komunikuje się z innymi komponentami szafy przez wewnętrzną szybką magistralę i obsługuje interfejsy szeregowe RS232, RS422 i RS485 w zależności od konfiguracji zainstalowanego modułu I\/O. Komunikacja Ethernet jest realizowana przez złącze RJ45 do integracji z przemysłowymi sieciami sterowania.\u003c\/p\u003e\n\u003cp\u003eModuł \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\"\u003e\u003ca class=\"decorated-link\" href=\"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbus-i-o-module\" target=\"_blank\"\u003e3500\/92-03-01-00 Ethernet\/RS232 Modbus I\/O Module\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ejest powszechnie stosowany w aplikacjach monitorowania maszyn, gdzie dane ochrony przed drganiami muszą być udostępniane systemom automatyki zakładowej. \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\"\u003e\u003ca class=\"decorated-link\" href=\"https:\/\/www.plcprotech.com\/products\/bently-nevada-136180-01-3500-92-communication-gateway-module\" target=\"_blank\"\u003eModuł bramki komunikacyjnej 136180-01 3500\/92\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eobsługuje komunikację z oprogramowaniem konfiguracyjnym i akwizycji danych Bently Nevada za pomocą własnych protokołów opartych na Ethernet.\u003c\/p\u003e\n\u003cp\u003eModel 3500\/92 jest przeznaczony do statycznych zmiennych procesowych i komunikacji alarmowej. Dynamiczne zbieranie przebiegów i funkcje diagnostyki przejściowej są obsługiwane oddzielnie przez moduł 3500\/22M Transient Data Interface.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObsługuje komunikację Modbus RTU i Modbus TCP\u003c\/li\u003e\n\u003cli\u003eMożliwość komunikacji Ethernet i szeregowej\u003c\/li\u003e\n\u003cli\u003eKompatybilny z systemami PLC, DCS, SCADA i HMI\u003c\/li\u003e\n\u003cli\u003eObsługuje interfejsy RS232, RS422 i RS485\u003c\/li\u003e\n\u003cli\u003ePołączenie Ethernet RJ45 dla sieci 10BASE-T\u003c\/li\u003e\n\u003cli\u003eDostęp do danych pomiarowych i alarmowych w całej szafie\u003c\/li\u003e\n\u003cli\u003eWewnętrzna szybka komunikacja w szafie\u003c\/li\u003e\n\u003cli\u003eObsługuje konfigurowalne mapowanie rejestrów Modbus\u003c\/li\u003e\n\u003cli\u003eKompatybilny z oprogramowaniem konfiguracyjnym szyny 3500\u003c\/li\u003e\n\u003cli\u003eModułowa architektura wymienna na gorąco\u003c\/li\u003e\n\u003cli\u003eDiody LED statusu komunikacji na panelu przednim\u003c\/li\u003e\n\u003cli\u003eObsługuje redundantne konfiguracje komunikacyjne\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystemy monitorowania drgań turbin\u003c\/li\u003e\n\u003cli\u003eSystemy ochrony sprężarek\u003c\/li\u003e\n\u003cli\u003eZakłady wytwarzania energii\u003c\/li\u003e\n\u003cli\u003eZakłady petrochemiczne\u003c\/li\u003e\n\u003cli\u003eMonitorowanie obrotowego sprzętu naftowego i gazowego\u003c\/li\u003e\n\u003cli\u003eSystemy ochrony maszyn przemysłowych\u003c\/li\u003e\n\u003cli\u003eProjekty integracji DCS\u003c\/li\u003e\n\u003cli\u003eMonitorowanie maszyn oparte na PLC\u003c\/li\u003e\n\u003cli\u003eSystemy komunikacji SCADA\u003c\/li\u003e\n\u003cli\u003eSieci automatyzacji procesów\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKategoriaSpecyfikacja\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eProducent\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eTyp produktu\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eModuł bramki komunikacyjnej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e3500\/92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003ePochodzenie\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eProtokoły komunikacyjne\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eModbus RTU, Modbus TCP\/IP, własny protokół Bently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eInterfejs Ethernet\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eEthernet 10BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eZłącze Ethernet\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInterfejsy szeregowe\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eRS232, RS422, RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003ePrędkość Ethernet\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eZużycie energii\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eTypowo 5,0 W z Modbus RS232\/RS422 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eZużycie energii\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eTypowo 5,6 W z Modbus RS485 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eCzas aktualizacji\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eMniej niż 1 sekunda na pełne dane szyny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-30°C do +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eWilgotność\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eWymiary\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e241 mm x 24,4 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eWaga\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e0,82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePołączenia \/ Interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eZłącze \/ Funkcja interfejsu\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003ePort Ethernet RJ45\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eKomunikacja Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003ePort RS232\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eSzeregowa komunikacja Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eInterfejs RS422\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDługodystansowa komunikacja szeregowa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eInterfejs RS485\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eKomunikacja Modbus wielopunktowa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eWewnętrzna magistrala szyny\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eWymiana danych na wysokiej prędkości w szynie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ch4\u003eBramka komunikacyjna 3500\/92\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eStruktura modelu:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3500\/92-AA-BB-CC\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKodOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eA\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eTyp modułu I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e01\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eModuł I\/O Modbus RS232\/RS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e02\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eModuł I\/O Modbus RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e03\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eModuł I\/O Ethernet\/RS232 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e04\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eModuł I\/O Ethernet\/RS485 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eB\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eTyp pamięci\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e01\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eNiska pamięć\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eC\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eOpcja zatwierdzenia agencji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e00\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eBrak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e01\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eCSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e02\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eCSA\/ATEX\/IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDodatkowe opcje\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eNumer częściOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e126M4118-01\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eZestaw do aktualizacji oprogramowania układowego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eStarsze moduły bram komunikacyjnych mogą wymagać aktualizacji oprogramowania układowego przed komunikacją z nowszymi modułami I\/O. Szczegóły zgodności znajdują się w instrukcji 3500\/92.\u003c\/p\u003e\n\u003ch3\u003eOkablowanie Ethernet\u003c\/h3\u003e\n\u003ch4\u003eStandardowy ekranowany kabel kategorii 5 10BASE-T z złączami RJ-45\u003c\/h4\u003e\n\u003cp\u003eModel bazowy: 138131-AAA\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKod kablaDługość\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e006\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e6 stóp (1,8 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e010\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e10 stóp (3 metry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e025\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e25 stóp (7,3 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e040\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e40 stóp (12 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e050\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e50 stóp (15 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e075\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e75 stóp (22,5 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e085\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e85 stóp (25,5 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e100\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e100 stóp (30,5 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e120\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e120 stóp (36,6 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e150\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e150 stóp (44,8 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e200\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e200 stóp (61 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e250\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e250 stóp (75 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e320\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e320 stóp (98 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNa zamówienie dostępne są niestandardowe długości kabli przez Bently Nevada Custom Products.\u003c\/p\u003e\n\u003ch3\u003eOkablowanie szeregowe (RS232)\u003c\/h3\u003e\n\u003ch4\u003eKabel RS232, host do 3500\/92\u003c\/h4\u003e\n\u003cp\u003eModel: 130419-AAAA-BB\u003c\/p\u003e\n\u003ch5\u003eDługość kabla\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKodDługość\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e0010\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e10 stóp (3 metry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e0025\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e25 stóp (7,5 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e0050\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e50 stóp (15 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e0100\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e100 stóp (30,5 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eInstrukcje montażu\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKodOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e01\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eNie zmontowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e02\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eZmontowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eKabel RS232, Honeywell PLCG do 3500\/92\u003c\/h4\u003e\n\u003cp\u003eModel: 130420-AAAA-BB\u003c\/p\u003e\n\u003ch5\u003eDługość kabla\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKodDługość\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e0010\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e10 stóp (3 metry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e0025\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e25 stóp (7,5 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e0050\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e50 stóp (15 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e0100\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e100 stóp (30,5 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eInstrukcje montażu\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKodOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e01\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eNie zmontowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e02\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eZmontowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eNumer częściOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e130119-01\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eKabel RS232, komputer host do konwertera RS232\/RS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOkablowanie szeregowe (RS422 \/ RS485)\u003c\/h3\u003e\n\u003cp\u003eKable RS422 mogą być używane do połączeń między szafami przy użyciu modułów I\/O Modbus RS485.\u003c\/p\u003e\n\u003ch4\u003eKabel RS422 z izolacją PVC, konwerter RS232\/RS422 do 3500\/92\u003c\/h4\u003e\n\u003cp\u003eModel: 130530-AAAA-BB\u003c\/p\u003e\n\u003ch4\u003eKabel RS422 z izolacją PVC, 3500\/92 do 3500\/92\u003c\/h4\u003e\n\u003cp\u003eModel: 129665-AAAA-BB\u003c\/p\u003e\n\u003ch4\u003eKabel RS422 z izolacją teflonową, konwerter RS232\/RS422 do 3500\/92\u003c\/h4\u003e\n\u003cp\u003eModel: 131109-AAAA-BB\u003c\/p\u003e\n\u003ch4\u003eKabel RS422 z izolacją teflonową, 3500\/92 do 3500\/92\u003c\/h4\u003e\n\u003cp\u003eModel: 131108-AAAA-BB\u003c\/p\u003e\n\u003ch5\u003eOpcje długości kabla\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKodDługość\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e0010\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e10 stóp (3 metry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e0025\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e25 stóp (7,5 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e0050\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e50 stóp (15 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e0100\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e100 stóp (30,5 metra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e0250\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e250 stóp (75 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e0500\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e500 stóp (150 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eInstrukcje montażu\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKodOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e01\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eNie zmontowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e02\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eZmontowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePrzedłużacz kabla RS422 \/ RS485\u003c\/h4\u003e\n\u003cp\u003eModel: 130531-AA-BB\u003c\/p\u003e\n\u003cp\u003eUżywany z zespołami kablowymi 130530, 129665, 131109 i 131108 do instalacji przekraczających 500 stóp (152 metry).\u003c\/p\u003e\n\u003ch5\u003eInstrukcje montażu\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKodOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e01\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eNie zmontowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e02\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eZmontowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eRodzaj izolacji\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eKodOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e01\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIzolacja PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e02\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eIzolacja teflonowa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCałkowita długość kabla RS485 może sięgać do 4000 stóp (1220 metrów).\u003c\/p\u003e\n\u003cp\u003eCałkowita długość kabla RS422 może sięgać do 4000 stóp (1220 metrów) między szafami.\u003c\/p\u003e\n\u003ch3\u003eCzęści zamienne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eNumer częściOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e04425545\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eOpaska uziemiająca na nadgarstek (jednorazowa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e137495-01\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUkład firmware (nieparzysty bank)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e137494-01\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUkład firmware (parzysty bank)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e136180-01\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eModuł bramki komunikacyjnej 3500\/92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e125736-01\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eModuł I\/O Modbus RS232\/RS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e133323-01\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eModuł I\/O Modbus RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e136188-01\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eModuł I\/O Ethernet\/RS232 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e136188-02\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eModuł I\/O Ethernet\/RS485 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eMiędzynarodowa dokumentacja techniczna Bently na DVD\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eNośniki dokumentacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAkcesoria\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eNumer częściOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e139036-01\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eKonwertery szeregowe 9-pinowe D-SUB \"Y\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e02230411\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eKonwerter RS232 na RS422 - 110 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e02230412\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eKonwerter RS232 na RS422 - 220 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e165M2516\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003ePrzełącznik 24-portowy 100\/1000 SFP BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransceivery Ethernet\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eNumer częściOpis\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e02200260\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eMęski 15-pinowy AUI do kabla światłowodowego (10BASE-FL) z połączeniem ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e02200261\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMęski 15-pinowy AUI do Thinnet (10BASE2) Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandardowe okablowanie Ethernet\u003c\/h3\u003e\n\u003ch4\u003eKabel ekranowany kategorii 5 10BASE-T z złączami RJ-45\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eNumer częściDługość kabla\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e02175190\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e6 stóp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e02175191\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e10 stóp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e02175192\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e25 stóp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666764624235,"sku":"3500\/92","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-92-communication-gateway-51o3zdgfljb_e1a39a26-bfe1-4ee3-8a8d-ce075dca0955.jpg?v=1765447201"},{"product_id":"bently-nevada-114m5330-01-3500-15-ac-and-dc-power-supply-module","title":"Moduł zasilania AC i DC Bently Nevada 114M5330-01 3500\/15","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e114M5330-01\u003c\/strong\u003e to wysokiej niezawodności, półwysokości \u003cstrong\u003emoduł zasilania prądu przemiennego i stałego\u003c\/strong\u003e zaprojektowany dla matrycy ochrony maszyn \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e. Ten niezbędny moduł konwersji zasilania montuje się w wyznaczonych gniazdach po lewej stronie obudowy szafy 3500, przekształcając szeroki zakres napięć wejściowych na wysoce regulowane, niskoszumowe szyny DC wymagane przez sąsiednie karty monitorujące i przetwarzające logikę. Pojedynczy moduł \u003cstrong\u003e114M5330-01\u003c\/strong\u003e jest w pełni zdolny do zasilania całej, gęstej struktury szafy 3500 samodzielnie.\u003c\/p\u003e\n\u003cp\u003eDla krytycznej infrastruktury wymagającej maksymalnej dostępności zasobów, konfiguracja szafy pozwala na integrację podwójnego zasilania. W systemie redundantnym karta o połowie wysokości pełni funkcję zasilania podstawowego, podczas gdy górny moduł pozostaje w aktywnym trybie zapasowym na gorąco. W przypadku awarii źródła podstawowego moduł zapasowy natychmiast przejmuje pełne obciążenie bez przerw w danych, degradacji sygnału czy zakłóceń w sieciach bezpieczeństwa blokad maszyn. Ta nowoczesna wersja sprzętu cechuje się wyższą efektywnością niż starsze modele i posiada niezależne wskaźniki \"SUPPLY OK\" na przednim panelu dla szybkiej diagnostyki stanu.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eArchitektura z podwójną redundancją umożliwiająca wymianę modułów na gorąco bez zakłócania aktywnej logiki szafy.\u003c\/li\u003e\n\u003cli\u003eWydajne filtrowanie szerokiego zakresu wejściowego do tłumienia silnych skoków napięcia i zakłóceń EMI.\u003c\/li\u003e\n\u003cli\u003eDedykowana dioda LED SUPPLY OK na przednim panelu zapewniająca natychmiastową diagnostykę pętli regulacji wewnętrznej.\u003c\/li\u003e\n\u003cli\u003eObudowa o połowie wysokości zoptymalizowana do układania strukturalnego po lewej stronie standardowej ramy systemu 3500.\u003c\/li\u003e\n\u003cli\u003eZintegrowana ochrona przed przepięciami i zwarciami zabezpiecza delikatne procesory instrumentów po stronie odbiorczej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDostarczanie wysoce stabilizowanego, redundantnego zasilania instrumentów w systemach ochrony turbin o dużej gęstości.\u003c\/li\u003e\n\u003cli\u003eCiągła infrastruktura zasilania pętli bezpieczeństwa w dużych turbinach parowych i krytycznych sprężarkach procesowych.\u003c\/li\u003e\n\u003cli\u003eWysokodostępne kondycjonowanie zasilania w lokalnych panelach morskich, pomp rurociągowych i panelach rozdzielczych do wytwarzania energii.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReferencja zamówienia produktu\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGłówne oznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15 (Zasilacze prądu przemiennego i stałego)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentyfikator części sprzętowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114M5330-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpcja typu modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniwersalny moduł zasilania AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114M5330-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł zasilania AC i DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat obudowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł o połowie wysokości (pasuje do górnych lub dolnych gniazd po lewej stronie)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKonfiguracja redundancji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObsługiwane przez parowanie hot-standby (dolne = podstawowe, górne = zapasowe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego (uniwersalne AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 do 264 Vac, nominalnie 110 do 220 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres częstotliwości wejściowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 do 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSzyny rozdziału napięcia wyjściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWewnętrzne wyjścia DC wieloszynowe dopasowane do backplane 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOcena izolacji galwanicznej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimalna izolacja ścieżki wejście-wyjście 3000 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWydajność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWysokowydajna topologia przełączająca z zoptymalizowanym rozpraszaniem ciepła\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElement wyświetlacza przedniego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZielona dioda LED „SUPPLY OK”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja szerokości modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja wysokości modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm (architektura o połowie wysokości)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja głębokości modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e242,0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŚrednia waga komponentu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,77 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wilgotności względnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksymalna wilgotność 95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWarstwa interfejsu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED na przedniej płycie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZielona kontrolka SUPPLY OK sygnalizująca prawidłową regulację napięcia wewnętrznego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfejs złącza tylnego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWielopinowy blok ostrzy łączący się bezpośrednio z modułem zasilania (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePołączenie magistrali backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWewnętrzne łącza śledzące dostarczające regulowane zasilanie przez gniazda szafy 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWkładanie modułu do szafy:\u003c\/strong\u003e Ostrożnie wsuwaj moduł o połowie wysokości w wyznaczone gniazda po lewej stronie ramy szafy 3500. Mocno osadź kartę w tylnym backplane i dokręć śruby na przedniej płycie ręcznie.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMapowanie gniazd redundantnych:\u003c\/strong\u003e Zainstaluj podstawowy zestaw zasilacza w dolnym gnieździe, a opcjonalną jednostkę zapasową umieść w górnym gnieździe bezpośrednio nad nim.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonserwacja Hot-Swap:\u003c\/strong\u003e Jeśli system z podwójnym zasilaniem jest włączony, możesz usunąć uszkodzony zasilacz lub odpowiadający mu tylny moduł zasilania (PIM) bez wyłączania szafy lub przerywania ochrony maszyn.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eŚrodki zapobiegawcze ESD:\u003c\/strong\u003e Zawsze przypinaj zatwierdzoną opaskę antystatyczną do niepomalowanej ramy szafy przed wyjmowaniem lub obsługą płytek drukowanych, aby chronić wrażliwe komponenty przed wyładowaniami elektrostatycznymi.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666768327019,"sku":"3500\/15 114M5330-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-114m5330-01-low-voltage-dc-pim-jdiabnmgabf_8b202e3e-5ae2-414c-af3e-38a332082979.jpg?v=1765447245"},{"product_id":"bently-nevada-3500-40m-proximitor-monitor","title":"Monitor Bently Nevada 3500\/40M Proximitor","description":"\u003cp style=\"color: #2d3748;\"\u003eModuł Bently Nevada 3500\/40M Proximitor Monitor to czterokanałowy moduł zaprojektowany do ciągłej ochrony maszyn i monitorowania krytycznych informacji o zasobach. Przyjmując sygnały z przetworników zbliżeniowych, \u003cstrong\u003eBently Nevada 3500\/40M\u003c\/strong\u003e przetwarza surowe sygnały czujników, aby śledzić istotne parametry dynamiczne i porównuje je z programowalnymi przez użytkownika progami alarmowymi. Głównym celem inżynierskim tego urządzenia jest sterowanie zautomatyzowanymi systemami ochrony maszyn przy jednoczesnym dostarczaniu wysokiej jakości danych diagnostycznych zespołom operacyjnym i utrzymaniowym.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eKluczowe cechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cp style=\"margin: 0 0 5px 0;\"\u003e\u003cstrong\u003eProjekt czterokanałowy:\u003c\/strong\u003e Konfigurowalny parami, umożliwiający podwójną funkcję na kanałach 1 i 2 oraz kanałach 3 i 4.\u003c\/p\u003e\n  \u003cp style=\"margin: 0 0 5px 0;\"\u003e\u003cstrong\u003eElastyczne kondycjonowanie sygnału:\u003c\/strong\u003e Obsługuje różnorodne pomiary maszynowe poprzez konfigurację programową, w tym drgania radialne, pozycję osiową, ekscentryczność, rozszerzalność różnicową i REBAM.\u003c\/p\u003e\n  \u003cp style=\"margin: 0 0 5px 0;\"\u003e\u003cstrong\u003eZaawansowana macierz nastaw:\u003c\/strong\u003e Umożliwia ustawienie progów Alert dla wszystkich aktywnych wartości statycznych oraz progów Niebezpieczeństwa dla dowolnych dwóch aktywnych wartości statycznych na kanał.\u003c\/p\u003e\n  \u003cp style=\"margin: 0 0 5px 0;\"\u003e\u003cstrong\u003eMonitorowanie stanu na pokładzie:\u003c\/strong\u003e Diody LED na panelu przednim wskazują stan modułu (OK), status komunikacji szafy (TX\/RX) oraz aktywne warunki obejścia kanału.\u003c\/p\u003e\n  \u003cp style=\"margin: 0 0 5px 0;\"\u003e\u003cstrong\u003eOchrona przed zwarciem:\u003c\/strong\u003e Buforowane wyjścia przetworników koncentrycznych na panelu przednim są w pełni chronione przed ciągłymi uszkodzeniami okablowania.\u003c\/p\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eZastosowania przemysłowe\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cp style=\"margin: 0 0 5px 0;\"\u003eMonitorowanie drgań wału i osiowego nacisku turbin parowych i gazowych.\u003c\/p\u003e\n  \u003cp style=\"margin: 0 0 5px 0;\"\u003eSystemy ochrony sprężarek odśrodkowych i osiowych.\u003c\/p\u003e\n  \u003cp style=\"margin: 0 0 5px 0;\"\u003eDiagnostyka dużych pomp przemysłowych, wentylatorów i silników elektrycznych.\u003c\/p\u003e\n  \u003cp style=\"margin: 0 0 5px 0;\"\u003eAnaliza łożysk tocznych z wykorzystaniem konfiguracji wysokoczęstotliwościowych REBAM.\u003c\/p\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px;\"\u003eKod opcji\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eOpis \/ konfiguracja sprzętowa\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e3500\/40M-A01-BXX\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eModuł I\/O Proximitor z wewnętrznym zakończeniem\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e3500\/40M-A02-BXX\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eModuł I\/O Proximitor z zewnętrznymi zakończeniami\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e3500\/40M-A03-BXX\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eModuł I\/O Proximitor z wewnętrznymi barierami i wewnętrznymi zakończeniami\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eOpcja B00\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBrak zatwierdzenia do stref zagrożonych wybuchem\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eOpcja B01\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eZatwierdzenie CNRTLus (Klasa I, Podział 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eOpcja B02\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eZatwierdzenie ATEX\/IECEx\/CSA (Klasa I, Strefa 2) - dostępne tylko z opcją A03\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eSpecyfikacja inżynierska\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eWejścia sygnałowe\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAkceptuje sygnały z 1 do 4 przetworników zbliżeniowych\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7,7 W, typowo\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e10 kOm (standardowe wejścia I\/O Proximitor i przyspieszenia)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eBuforowana impedancja wyjściowa\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e550 omów\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eZasilanie przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eCzułość radialna \/ osiowa \/ ekscentryczności\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3,94 mV\/mikrometr (100 mV\/mil) lub 7,87 mV\/mikrometr (200 mV\/mil)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eCzułość rozszerzalności różnicowej\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0,394 mV\/mikrometr (10 mV\/mil) lub 0,787 mV\/mikrometr (20 mg\/mil)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eCzułość REBAM\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e40 mV\/mikrometr (1000 mV\/mil) lub 80 mV\/mikrometr (2000 mV\/mil)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eDokładność filtra bezpośredniego\/przerwy\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTypowo w granicach +\/-0,33 procent pełnej skali, maksymalnie +\/-1 procent\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eDokładność fazy\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBłąd fazy maksymalnie 3 stopnie\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eDokładność nastawy alarmu\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eW granicach 0,13 procent wartości zadanej\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eTemperatura pracy (standardowy I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eTemperatura pracy (barierowy I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0°C do +65°C (32°F do +150°F)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e95 procent, bez kondensacji\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eWymiary modułu monitorującego\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eWymagania dotyczące miejsca w szafie\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 pełnowysokie gniazdo z przodu (monitor), 1 pełnowysokie gniazdo z tyłu (moduł I\/O)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStany Zjednoczone\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eWaga wysyłkowa (obliczona)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1,5 kg (zawiera moduł główny, kartę I\/O z tyłu oraz opakowanie ochronne)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eWymiary opakowania (obliczone)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e300 mm x 280 mm x 65 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px; margin-bottom: 15px; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e Odłącz wszystkie źródła zasilania od szafy systemu 3500 przed wkładaniem lub wyjmowaniem modułów monitorujących lub kart I\/O z tyłu. Przepięcia wysokiego napięcia mogą zniszczyć wrażliwe komponenty CMOS. Upewnij się, że okablowanie polowe jest całkowicie odłączone od zasilania i że zastosowano odpowiednie procedury blokady i oznakowania (LOTO) przed manipulacją przy połączeniach zacisków.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; padding: 2px 8px; font-weight: bold; margin-right: 8px;\"\u003e1\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eSprawdź zgodność gniazda w szafie. Główny moduł monitorujący 3500\/40M musi być włożony wyłącznie do pełnowysokiego gniazda z przodu, a odpowiadający mu moduł I\/O z tyłu musi być umieszczony bezpośrednio za nim w odpowiadającym pełnowysokim gnieździe tylnym.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; padding: 2px 8px; font-weight: bold; margin-right: 8px;\"\u003e2\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eMocno osadź moduł w prowadnicach szafy. Delikatnie dociśnij przedni panel, aż tylne złącza pewnie zahaczą się o płytę tylnią. Dokładnie dokręć dwa wbudowane śruby motylkowe na przednim panelu, aby zapewnić stałe uziemienie szafy.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; padding: 2px 8px; font-weight: bold; margin-right: 8px;\"\u003e3\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003ePodłącz przedłużenia przetworników zbliżeniowych do tylnego paska zacisków I\/O lub złącza typu Euro. Unikaj prowadzenia linii czujników niskonapięciowych równolegle do kabli zasilających trójfazowych o wysokim natężeniu, aby zapobiec wprowadzaniu zakłóceń elektromagnetycznych.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; padding: 2px 8px; font-weight: bold; margin-right: 8px;\"\u003e4\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003ePodłącz swoje stanowisko inżynierskie do szafy za pomocą oprogramowania 3500 Rack Configuration Software. Załaduj plik bazowy, zweryfikuj ustawienia czułości konkretnego przetwornika (np. 200 mV\/mil) i przypisz wymagane kanały do odpowiednich przekaźników ochronnych.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666769473899,"sku":"3500\/40M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-40m-position-monitor-4v5ni1q5oy4_0c5cd3f0-33a2-42c2-baf1-b7dc871d2378.jpg?v=1765447262"},{"product_id":"bently-nevada-3500-20-125744-02-rack-interface-module","title":"Moduł interfejsu szafy Bently Nevada 3500\/20 125744-02","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003eBently Nevada 125744-02\u003c\/strong\u003e to pełnowysokowy \u003cstrong\u003eStandardowy Moduł Interfejsu Stojaka\u003c\/strong\u003e (RIM), który służy jako główne łącze danych i konfiguracji do Systemu Ochrony Maszyn Serii 3500. Moduł ten obsługuje specjalistyczny, własnościowy protokół komunikacyjny zaprojektowany do bezpiecznej konfiguracji sprzętu monitorującego obudowy oraz pobierania niekrytycznych informacji diagnostycznych maszyn dla pakietów oprogramowania nadrzędnego. Musi być umieszczony w slocie 1 struktury stojaka obudowy bezpośrednio obok modułów zasilania systemu. Podczas gdy \u003cstrong\u003e125744-02\u003c\/strong\u003e wykonuje kluczowe role zarządzania bazowego, w tym przetwarzanie globalnych wejść kontaktowych systemu, obsługę sterowania mnożnikami wyłączeń oraz uruchamianie wewnętrznego przekaźnika OK, działa niezależnie od krytycznej ścieżki bezpieczeństwa wyłączenia maszyny, zapewniając, że jakiekolwiek działania serwisowe na poziomie modułu nie mają wpływu na ciągłe, normalne operacje ochronne systemu monitorowania.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandardowa architektura pełnowysokiego przedniego stojaka zoptymalizowana pod integrację w slocie 1 \u003c\/li\u003e\n\u003cli\u003eBezpośredni fizyczny interfejs do programowania systemu własnościowego i zbierania danych diagnostycznych \u003c\/li\u003e\n\u003cli\u003eModuł blokady klucza na przednim panelu umożliwiający wyraźne przełączanie sprzętu między trybami RUN i PROGRAM \u003c\/li\u003e\n\u003cli\u003eDedykowane wyjście przekaźnikowe \"OK\" wskazujące ogólny stan zdrowia szafy ochronnej 3500 i status diagnostyki wewnętrznej \u003c\/li\u003e\n\u003cli\u003eDiody LED statusu na przednim panelu zapewniające fizyczną weryfikację komunikacji systemu, błędów i stanów wyłączenia \u003c\/li\u003e\n\u003cli\u003eZintegrowany przycisk resetu na przednim panelu do kasowania aktywnych zatrzaśniętych alarmów maszynowych \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGłówny punkt integracji sprzętowej dla standardowej konfiguracji w pętlach ochrony maszyn 3500 \u003c\/li\u003e\n\u003cli\u003eInterfejsy zbierania danych monitorowania stanu dla przemysłowych turbin energetycznych i linii sprężania \u003c\/li\u003e\n\u003cli\u003eCentralna zlokalizowana platforma sterująca dla dużych obudów maszyn wieloslotowych i ram ochrony obrotu \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (firma Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125744-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardowy moduł interfejsu do szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie energii 4,75 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfejs przedniego panelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKomunikacja szeregowa RS232 z prędkością 38,4 kbaud \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalne obciążenie przekaźnika OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5A przy 24 V DC \/ 120 V AC (maks. 120 W \/ 600 VA zasilania przełączanego) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania dotyczące miejsca w szafie (płyta główna)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe gniazdo przednie (Slot 1) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm (9,5 cala x 0,96 cala x 9,52 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg (2,0 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eElement interfejsu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort konfiguracyjny na przednim panelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowany interfejs szeregowy RS232 wykorzystujący protokół własnościowy do lokalnego zbierania danych i konfiguracji szafy za pomocą laptopa \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrzełącznik zamka konfiguracyjnego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObrotowy fizyczny zamek bezpieczeństwa do przełączania między trybem RUN (blokuje zmiany) a trybem PROGRAM (umożliwia konfigurację szafy) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiodowe wskaźniki stanu obudowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLampki panelu OK, TX\/RX, TM (Trip Multiply) oraz CONFIG OK wskazujące działanie modułu i status komunikacji wielokartowej \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOgraniczenia gniazd\u003c\/strong\u003e: Wsuń kartę interfejsu wyraźnie do pełnowymiarowego gniazda Slot 1 po lewej stronie szafy ochronnej maszyny.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eŚrodki ostrożności przeciw wyładowaniom elektrostatycznym\u003c\/strong\u003e: Użyj odpowiedniego paska uziemiającego na nadgarstek podłączonego do solidnego uziemienia elektrycznego przed włożeniem lub instalacją kart obwodów.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegralność zamka kluczykowego\u003c\/strong\u003e: Przekręć przedni przełącznik kluczykowy do pozycji RUN i wyjmij fizyczny klucz, aby skutecznie zablokować nieautoryzowane próby modyfikacji zdalnej lub lokalnej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZarządzanie termiczne\u003c\/strong\u003e: Upewnij się, że drogi chłodzenia są całkowicie drożne, utrzymując temperaturę otoczenia bezpośrednio wokół obudowy modułu poniżej 65°C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666846609771,"sku":"3500\/20 125744-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-20-125744-02-rack-interface-module-mrtcejlorgu_bf96715c-43be-4669-8335-5f44ac2e4e49.jpg?v=1765448936"},{"product_id":"bently-nevada-135473-01-3500-25-keyphasor-i-o-module-internal-barriers","title":"Moduł wejścia\/wyjścia Bently Nevada 135473-01 3500\/25 Keyphasor (wewnętrzne bariery)","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eBently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto specjalistyczny moduł I\/O o połowie wysokości zaprojektowany dla systemu\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced Keyphasor. Ta konkretna konfiguracja integruje\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBariery Wewnętrzne\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoraz\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eZakończenia Wewnętrzne\u003c\/strong\u003e, zapewniając sprzętowy interfejs bezpieczeństwa wewnętrznego dla przetworników umieszczonych w strefach zagrożonych. Moduł jest zaprojektowany do odbioru i przetwarzania sygnałów impulsowych raz na obrót lub wielokrotnie na obrót z sond zbliżeniowych lub czujników magnetycznych, które są niezbędne do obliczania prędkości obrotowej maszyny oraz dostarczania odniesienia fazowego do analizy drgań.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epełni funkcję fizycznego interfejsu w szafie 3500, zapewniając izolację elektryczną i kondycjonowanie sygnału dla krytycznej ochrony maszyn. Chociaż moduł obsługuje pomiary fazy, jest zoptymalizowany do monitorowania prędkości wału z wysoką dokładnością. Korzystając z wersji z barierą wewnętrzną, moduł zapewnia bezpieczny punkt połączenia, który ogranicza energię elektryczną wysyłaną do czujników polowych, spełniając rygorystyczne przemysłowe normy bezpieczeństwa dla atmosfer wybuchowych.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuł I\/O Keyphasor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeria 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp zakończenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZakończenia wewnętrzne\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfejs bezpieczeństwa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBariery wewnętrzne (typ Zenera)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKanały wejściowe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 sygnały przetworników (proximity lub czujnik magnetyczny)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypowo 3,2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum 21,8 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZakres sygnału (bez izolacji)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+0,8 V do -21,0 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimalna prędkość czujnika magnetycznego\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003e 200 obr.\/min (3,3 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 103,1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,46 kg (1,01 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C do +65°C (32°F do +150°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% bez kondensacji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cp\u003eZakupy przemysłowe powinny koncentrować się na konkretnym numerze części, aby zapewnić kompatybilność z konfiguracją monitora 3500\/25.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e: Moduł I\/O Keyphasor z barierami wewnętrznymi i zakończeniami wewnętrznymi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStan\u003c\/strong\u003e: Nowy oryginalny\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDostępność\u003c\/strong\u003e: Magazyn części zamiennych\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł może zapewnić izolację dla aplikacji Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, jest kompatybilny z aplikacjami Proximitor, ale wymaga zewnętrznego zasilania do zapewnienia izolacji.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest główny cel projektowy wersji z izolowanym I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZostał stworzony specjalnie do zastosowań z czujnikami magnetycznymi, gdzie sygnały są podłączone równolegle do wielu urządzeń, takich jak systemy sterowania.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCo się dzieje, gdy sygnały wejściowe przekraczają określony zakres?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSygnały przekraczające określony zakres napięcia są wewnętrznie ograniczane przez obwody modułu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOdwołanie techniczne: Okablowanie, zwory i specyfikacje\u003c\/h3\u003e\n\u003ch3\u003e1. OKABLOWANIE KANAŁU I DEFINICJE PINÓW\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ejest wewnętrznym modułem zakończenia I\/O z wbudowanymi barierami galwanicznymi. Posiada dwa niezależne listwy zaciskowe dla Kanału 1 i Kanału 2.\u003c\/p\u003e\n\u003ch4\u003eA. Okablowanie czujnika zbliżeniowego (3-przewodowe)\u003c\/h4\u003e\n\u003cp\u003eDla standardowych czujników prądów wirowych (np. seria 3300 XL):\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR (-24V):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWyjście zasilania dla Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM (GND):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWspólny\/zwrotny sygnał.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG (OUT):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWejście sygnału napięciowego impulsu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Okablowanie czujnika magnetycznego (pasywne 2-przewodowe)\u003c\/h4\u003e\n\u003cp\u003eDla samogenerujących elektromagnetycznych czujników prędkości:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz do dodatniego (+) przewodu czujnika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz do ujemnego (-) przewodu czujnika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMuszą pozostać odłączone (pływające).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Ekranowanie i uziemienie IS\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSHLD (Ekran):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz ekrany kabli polowych do tego dedykowanego zacisku.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUziemienie IS :\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModuł ten musi być uziemiony przez\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01 Moduł uziemienia bariery\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edo dedykowanej szyny uziemienia bezpieczeństwa iskrobezpiecznego, aby zapewnić integralność przeciwwybuchową.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. KONFIGURACJE ZWOREK SPRZĘTOWYCH\u003c\/h3\u003e\n\u003cp\u003eZworki znajdują się na wewnętrznej płytce drukowanej i muszą być ustawione przed instalacją.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eZworka zasilania przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eZworka sprzęgająca wejście\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunkcja logiczna\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCzujnik zbliżeniowy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eINT\u003c\/strong\u003e (Wewnętrzny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC\u003c\/strong\u003e (Prąd stały)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDostarcza zasilanie; umożliwia polaryzację DC.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCzujnik magnetyczny\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEXT\u003c\/strong\u003e (Zewnętrzny\/WYŁĄCZONY)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC\u003c\/strong\u003e (Prąd zmienny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOdłącza zasilanie; filtruje szumy DC.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eWAŻNE:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eZawsze wyłącz zasilanie szafy 3500 lub usuń moduł monitorujący przed regulacją zworek, aby uniknąć łuku elektrycznego.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr\u003e\n\u003ch3\u003e3. PODSTAWOWE SPECYFIKACJE WYDAJNOŚCI\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePojemność kanału:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 niezależne kanały wejściowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZakres częstotliwości:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 do 1 200 000 cpm (\u003cstrong\u003e0,017 Hz do 20 kHz\u003c\/strong\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZakres napięcia wejściowego:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+5V do -11V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(specjalnie dla Barier I\/O).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTryby kondycjonowania:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg automatyczny:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMinimalny sygnał 2 V szczyt-szczyt; minimalna prędkość 120 obr.\/min.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg ręczny:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegulowany od 0 do -20 V DC; minimalny sygnał 500 mV; obsługuje niskie prędkości do 1 obr.\/min.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eŚrodowiskowe:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eZużycie energii:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3,2 Waty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(typowe).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperatura pracy:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0°C do 65°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. CERTYFIKATY STREF ZAGROŻONYCH\u003c\/h3\u003e\n\u003cp\u003eZaprojketowany do środowisk wysokiego ryzyka:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmeryka Północna:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKlasa I, Div 2, Grupy A, B, C, D.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEuropa (ATEX):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eII 1 G [EEx ia] IIC (Wejścia ocenione na Strefę 0).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e5. WSPARCIE KONFIGURACJI SYSTEMU\u003c\/h3\u003e\n\u003cp\u003ePo fizycznej instalacji użyj\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoprogramowania do konfiguracji szafy 3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaby zweryfikować:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUstawienia histerezy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAby zapobiec fałszywym wyzwoleniom na zakłóconych sygnałach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrientacja:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUstawienie kierunku impulsu (dodatni\/ujemny).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAktywne kanały:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eZapewnienie zgodności ustawień zworki w oprogramowaniu z fizycznymi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCZĘŚĆ 2: SCHEMATY ZACISKÓW I KONFIGURACJA OPROGRAMOWANIA\u003c\/h3\u003e\n\u003ch3\u003e1. ROZKŁAD PINÓW BLOKU ZACISKÓW (A\/B\/C\/D)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eużywa określonej sekwencji 4 zacisków dla każdego kanału. Poniżej znajduje się mapa połączeń do podłączenia okablowania terenowego:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eZacisk\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEtykieta\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCzujnik zbliżeniowy (3-przewodowy)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCzujnik magnetyczny (2-przewodowy)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePWR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 V DC zasilanie (biały)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBRAK POŁĄCZENIA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWspólny\/masa (czarny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSygnał ujemny (-)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWejście sygnału (czerwony)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSygnał dodatni (+)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSHLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEkranowanie\/przewód odprowadzający\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEkranowanie\/przewód odprowadzający\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e2. KONFIGURACJA OPROGRAMOWANIA (KONFIGURACJA SZAFY 3500)\u003c\/h3\u003e\n\u003cp\u003ePo zainstalowaniu sprzętu musisz skonfigurować następujące elementy w oprogramowaniu:\u003c\/p\u003e\n\u003ch4\u003eA. Ustawienia progu\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg automatyczny\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSystem automatycznie oblicza punkt wyzwalania na poziomie 50% amplitudy sygnału.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNajlepsze dla\u003c\/strong\u003e: Standardowych prędkości pracy (\u0026gt;120 obr.\/min) z czystymi, stałymi impulsami.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg ręczny\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRęcznie ustawiasz stałe napięcie (np. -8,0 V DC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrongNajlepsze dla\u003c\/strong\u003e: Rozruchów niskich prędkości lub sygnałów z istotnymi „zakłóceniami” lub szumem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWskazówka dotycząca obliczeń\u003c\/strong\u003e: Ustaw próg na środek między szczytem impulsu a sygnałem bazowym.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Histereza (redukcja szumów)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDla\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eczujników magnetycznych\u003c\/strong\u003e powinieneś ustawić wartość histerezy (zwykle\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0,2V do 0,5V\u003c\/strong\u003e), aby zapobiec „podwójnemu wyzwalaniu” monitora, jeśli sygnał jest zakłócony podczas przekraczania progu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Aktywne zbocze (kierunek)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNegatywne zbocze\u003c\/strong\u003e: Wyzwala, gdy sygnał przechodzi z 0V do -24V (standard dla większości sond Bently).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePozytywne zbocze\u003c\/strong\u003e: Wyzwala, gdy sygnał przesuwa się w kierunku dodatnim.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. KRYTYCZNA LISTA KONTROLNA INSTALACJI\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUziemienie bariery\u003c\/strong\u003e: Upewnij się, że moduł\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ejest zainstalowany w szafie. Bez tego 135473-01 nie może prawidłowo uziemić wewnętrznych barier bezpieczeństwa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKontrola zworki\u003c\/strong\u003e: Podwójnie sprawdź, czy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezworki Kanału 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ei\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKanału 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epasują do odpowiednich czujników. Częstym błędem jest pozostawienie zworki PWR na\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprzy użyciu czujnika magnetycznego, co może powodować zakłócenia lub nagrzewanie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKodowanie\u003c\/strong\u003e: Używaj\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estopni C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoraz\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCelsjusza\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ew swojej dokumentacji technicznej, aby uniknąć problemów z uszkodzonymi znakami, które wcześniej występowały w Twoim CMS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847134059,"sku":"135473-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135473-01-motion-controller-module-with-316l-stainless-steel-case-material-ag55zssqu3e_fe8b3db7-fd2e-41ca-ad85-8851d4d47e88.jpg?v=1765448946"},{"product_id":"bently-nevada-3500-61-02-00-133827-02-temperature-monitor-rtd-tc-non-isolated-i-o-module","title":"Moduł Wejścia\/Wyjścia Nieizolowany Monitor Temperatury RTD\/TC Bently Nevada 3500\/61-02-00 133827-02","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e3500\/61-02-00\u003c\/strong\u003e to sześciokanałowy moduł monitorowania temperatury zaprojektowany dla \u003cstrong\u003esystemu ochrony maszyn Bently Nevada 3500\u003c\/strong\u003e. Moduł akceptuje zarówno wejścia temperatury RTD, jak i termoparowe oraz wykonuje ciągły pomiar temperatury i funkcje porównania alarmów dla krytycznych zastosowań maszyn obrotowych.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e133827-02\u003c\/strong\u003e Moduł I\/O RTD\/TC nieizolowany używa zewnętrznych zakończeń i obsługuje mieszane konfiguracje wejść RTD i TC. Użytkownicy mogą konfigurować poszczególne kanały przez oprogramowanie do konfiguracji szafy 3500 do pracy z RTD lub termoparą.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/61\u003c\/strong\u003e seria różni się od \u003cstrong\u003e3500\/60\u003c\/strong\u003e poprzez zapewnienie wyjść rejestratora dla każdego kanału monitorującego. Wyjścia rejestratora obsługują transmisję 4 do 20 mA proporcjonalną do skonfigurowanego zakresu pełnej skali monitora.\u003c\/p\u003e\n\u003cp\u003eModuł obsługuje do sześciu wejść przetworników i zapewnia programowalne progi alarmów Alert i Danger. W systemach potrójnej redundancji modularnej (TMR) monitory temperatury instalowane są w grupach po trzy, aby wspierać redundantną logikę głosowania i tolerancję błędów.\u003c\/p\u003e\n\u003cp\u003eModuł nadaje się do systemów monitorowania turbin, zespołów sprężarek, zakładów procesowych, obiektów wytwarzania energii oraz zastosowań ochrony maszyn przemysłowych wymagających nadzoru temperatury i przetwarzania alarmów.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSześciokanałowy monitoring temperatury\u003c\/li\u003e\n\u003cli\u003eObsługuje wejścia RTD i termopary\u003c\/li\u003e\n\u003cli\u003eObsługa mieszanej konfiguracji kanałów RTD i TC\u003c\/li\u003e\n\u003cli\u003eZewnętrzne zakończenia, nieizolowany projekt I\/O\u003c\/li\u003e\n\u003cli\u003eWyjścia rejestratora dla wszystkich sześciu kanałów\u003c\/li\u003e\n\u003cli\u003eUstawienia alarmów konfigurowane przez użytkownika\u003c\/li\u003e\n\u003cli\u003eTryb pomiaru RTD lub TC konfigurowany programowo\u003c\/li\u003e\n\u003cli\u003eKompatybilny z oprogramowaniem do konfiguracji szafy 3500\u003c\/li\u003e\n\u003cli\u003eObsługuje architekturę systemu TMR\u003c\/li\u003e\n\u003cli\u003eDiody LED na panelu przednim: OK, TX\/RX i Bypass\u003c\/li\u003e\n\u003cli\u003eWyjścia rejestratora 4 do 20 mA\u003c\/li\u003e\n\u003cli\u003eKonfiguracja pełnej skali kanału przez oprogramowanie\u003c\/li\u003e\n\u003cli\u003eNie wymaga kalibracji\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitorowanie temperatury turbin parowych\u003c\/li\u003e\n\u003cli\u003eSystemy ochrony turbin gazowych\u003c\/li\u003e\n\u003cli\u003eNadzór temperatury sprężarek\u003c\/li\u003e\n\u003cli\u003eMonitorowanie przemysłowych maszyn obrotowych\u003c\/li\u003e\n\u003cli\u003eSystemy zatrzymania zakładów procesowych\u003c\/li\u003e\n\u003cli\u003eOchrona urządzeń do wytwarzania energii\u003c\/li\u003e\n\u003cli\u003eMonitorowanie procesów petrochemicznych\u003c\/li\u003e\n\u003cli\u003eMonitorowanie maszyn w obiektach LNG\u003c\/li\u003e\n\u003cli\u003eSystemy alarmowe krytycznego sprzętu\u003c\/li\u003e\n\u003cli\u003eInstalacje ochrony maszyn TMR\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/61-02-00: Kompletny zestaw monitora RTD\/TC z zewnętrznymi zakończeniami\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOkreśla zestaw łączony zawierający główny moduł monitora 3500\/61 oraz specyficzną nieizolowaną tylną płytkę I\/O.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: Opcja typu modułu I\/O\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eModuł I\/O RTD\/TC nieizolowany z zewnętrznymi zakończeniami (numer części tylnej płytki: \u003cstrong\u003e133827-02\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Opcja zatwierdzenia agencji\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNie wymagane zatwierdzenia ani certyfikaty agencji stref zagrożonych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCzęści zamienne i akcesoria\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNumer części \u003cstrong\u003e133827-02\u003c\/strong\u003e: Moduł I\/O RTD\/TC nieizolowany 3500\/61 do wymiany z zewnętrznymi zakończeniami.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eKategoria\u003c\/th\u003e\n\u003cth\u003eSpecyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp produktu\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O monitora temperatury RTD\/TC nieizolowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeria\u003c\/td\u003e\n\u003ctd\u003eSeria 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/61-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer części zamiennej\u003c\/td\u003e\n\u003ctd\u003e133827-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKanały wejściowe\u003c\/td\u003e\n\u003ctd\u003e1 do 6 sygnałów przetworników RTD lub TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedancja wejściowa\u003c\/td\u003e\n\u003ctd\u003e10 MΩ na każde wejście przewodu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZużycie energii\u003c\/td\u003e\n\u003ctd\u003eNominalnie 9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWyjście rejestratora\u003c\/td\u003e\n\u003ctd\u003e+4 do +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNapięcie zgodności\u003c\/td\u003e\n\u003ctd\u003e0 do +12 V DC na obciążeniu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpór obciążenia\u003c\/td\u003e\n\u003ctd\u003e0 do 600 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRozdzielczość\u003c\/td\u003e\n\u003ctd\u003e0,3662 uA na bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eŹródło prądu RTD\u003c\/td\u003e\n\u003ctd\u003e925 +\/-15 uA przy 25°C na przetwornik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres opóźnienia alarmu\u003c\/td\u003e\n\u003ctd\u003eAlert: 1 do 60 s, Niebezpieczeństwo: 1 do 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary monitora\u003c\/td\u003e\n\u003ctd\u003e241,3 x 24,4 x 241,8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga monitora\u003c\/td\u003e\n\u003ctd\u003e0,91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary modułu I\/O\u003c\/td\u003e\n\u003ctd\u003e241,3 x 24,4 x 99,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga modułu I\/O\u003c\/td\u003e\n\u003ctd\u003e0,45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymaganie dotyczące slotu w szafie\u003c\/td\u003e\n\u003ctd\u003e1 pełnowysokościowy przedni slot i 1 tylny slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePochodzenie\u003c\/td\u003e\n\u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje RTD\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp RTD\u003c\/td\u003e\n\u003ctd\u003eZakres pomiarowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 omów RTD platynowy alfa 0,00385\u003c\/td\u003e\n\u003ctd\u003e-200°C do +850°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 omów RTD platynowy alfa 0,00392\u003c\/td\u003e\n\u003ctd\u003e-200°C do +700°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 omów RTD niklowy\u003c\/td\u003e\n\u003ctd\u003e-80°C do +260°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 omów RTD miedziany\u003c\/td\u003e\n\u003ctd\u003e-100°C do +260°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje termopary\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp termopary\u003c\/td\u003e\n\u003ctd\u003eZakres pomiarowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp E\u003c\/td\u003e\n\u003ctd\u003e-100°C do +1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp J\u003c\/td\u003e\n\u003ctd\u003e-18°C do +760°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp K\u003c\/td\u003e\n\u003ctd\u003e-18°C do +1370°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp T\u003c\/td\u003e\n\u003ctd\u003e-160°C do +400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje kondycjonowania sygnału\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametr\u003c\/td\u003e\n\u003ctd\u003eSpecyfikacja\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRozdzielczość RTD i termopary\u003c\/td\u003e\n\u003ctd\u003e1°C lub 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRozdzielczość RTD miedzianego\u003c\/td\u003e\n\u003ctd\u003e1°C lub 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDokładność kompensacji zimnego złącza\u003c\/td\u003e\n\u003ctd\u003e+\/-1°C przy 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDokładność alarmu\u003c\/td\u003e\n\u003ctd\u003eW granicach 0,13% wartości docelowej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDokładność zewnętrznego zakończenia nieizolowanego\u003c\/td\u003e\n\u003ctd\u003e+\/-1°C przy 25°C standardowej szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDokładność szafy przelotowej\u003c\/td\u003e\n\u003ctd\u003e+\/-3°C przy 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWyjścia i wskaźniki\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWskaźnik lub wyjście\u003c\/td\u003e\n\u003ctd\u003eFunkcja\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDioda OK\u003c\/td\u003e\n\u003ctd\u003eWskazuje prawidłową pracę monitora\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDioda TX\/RX\u003c\/td\u003e\n\u003ctd\u003eWskazuje komunikację z modułami szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDioda LED obejścia\u003c\/td\u003e\n\u003ctd\u003eWskazuje tryb obejścia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWyjścia rejestratora\u003c\/td\u003e\n\u003ctd\u003eIndywidualne wyjścia 4 do 20 mA na kanał\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUwagi inżynierskie\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWybór Platinum RTD\u003c\/strong\u003e: Platinum RTD z współczynnikiem alfa 0,00385 spełniają globalne standardy przemysłowe i są zalecane do wszystkich nowych instalacji pętli temperaturowych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOdporność rejestratora na zwarcia\u003c\/strong\u003e: Wewnętrzne obwody gwarantują, że podstawowy monitoring maszyn i logika alarmowa pozostają nienaruszone przez zwarcia w zewnętrznych pętlach rejestratora.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePróg dolny i górny\u003c\/strong\u003e: Wewnętrzny procesor zapewnia zarówno górne, jak i dolne granice alarmowe dla ochrony wielokierunkowej (np. stany kriogeniczne lub przegrzania).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWymagania TMR\u003c\/strong\u003e: Przy konfiguracji na potrójną modularną redundancję trzy identyczne monitory temperatury muszą znajdować się w kolejnych, sąsiadujących gniazdach przedniego panelu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWytyczne terenowe\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOkablowanie zewnętrznego zakończenia\u003c\/strong\u003e: Prowadź wszystkie przewody RTD lub termopary do zewnętrznego bloku zaciskowego, zapewniając czyste, gazoszczelne połączenia dla utrzymania dokładności CJC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUziemienie ekranów\u003c\/strong\u003e: Ekrany kabli należy zakończyć wyłącznie na wyznaczonym zacisku uziemienia ekranu w module I\/O, aby zapobiec pętlom masy i chronić przed zakłóceniami elektromagnetycznymi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDopasowanie czujnika CJC\u003c\/strong\u003e: Upewnij się, że czujnik kompensacji zimnego złącza jest solidnie zamocowany do podstawy zacisku, aby zapewnić dokładną kompensację otoczenia podczas pomiarów termoparą.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimalizacja rezystancji przewodów\u003c\/strong\u003e: W przypadku podłączeń RTD 3- i 4-przewodowych utrzymuj jednakową długość przewodów, aby zrównoważyć spadek napięcia i zapewnić dokładną kompensację mostka.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne i dotyczące zamówień\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jaka jest podstawowa różnica między modułami 3500\/60 a 3500\/61?\u003c\/strong\u003e O: Oba moduły oferują identyczny monitoring temperatury i logikę alarmową, ale 3500\/61 posiada sześć niezależnych wyjść rejestratora +4 do +20 mA, których 3500\/60 nie ma.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy ta konkretna opcja modułu I\/O bez izolacji zapewnia izolację kanał do kanału?\u003c\/strong\u003e O: Nie, to jest opcja 02, która nie jest izolowana; jeśli potrzebna jest izolacja kanał do kanału, aby przeciwdziałać silnym usterkom uziemienia lub przepięciom linii wysokiego napięcia, należy zamiast tego wybrać wersję modułu I\/O z izolacją.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy kalibracja w terenie jest wymagana dla modułu 3500\/61 podczas instalacji?\u003c\/strong\u003e O: Nie jest wymagana kalibracja w terenie, ponieważ zakresy pełnej skali i typy czujników są konfigurowane cyfrowo za pomocą oprogramowania 3500 Rack Configuration Software.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847691115,"sku":"3500\/61-02-00 133827-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-02-00-133827-02-rtd-tc-temperature-i-o-module-tul1fywpxs1_6cd7fe54-1ece-464e-8d43-bdb06cb565fb.jpg?v=1765448969"},{"product_id":"bently-nevada-3500-33-04-00-149992-04-low-current-16-channel-failsafe-relay-output-module","title":"Bently Nevada 3500\/33-04-00 149992-04 Low Current 16-Channel Failsafe Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/33-04-00 149992-04\u003c\/strong\u003e is a \u003cstrong\u003e16-channel failsafe relay output module\u003c\/strong\u003e used as a main or spare module in \u003cstrong\u003e3500 machinery protection systems\u003c\/strong\u003e. It provides 16 independently programmable relay outputs with alarm drive logic, supporting AND\/OR logic combinations of alert, danger, Not-OK statuses, and measured variables from any monitor channel. Each relay output can perform voting logic and integrates with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module interfaces with \u003cstrong\u003ePLC, DCS, SIS, and TSI systems\u003c\/strong\u003e, offering both normally de-energized (ND) and normally energized (NE) operation selectable in four groups of four channels. Front-panel LEDs indicate module status, communication activity, and channel alarm states.\u003c\/p\u003e\n\u003cp\u003eIt supports low current switching applications with gold-plated contacts, suitable for standard, failsafe, or hazardous area configurations. Module compatibility includes installation to the right of the Transient Data Interface (TDI) in a \u003cstrong\u003e3500 rack\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 relay outputs with independent programmable logic\u003c\/li\u003e\n\u003cli\u003eAlarm drive logic using AND\/OR conditions\u003c\/li\u003e\n\u003cli\u003eSelectable normally de-energized (ND) or normally energized (NE) operation\u003c\/li\u003e\n\u003cli\u003eFront-panel LEDs for OK, TX\/RX, and channel alarm status\u003c\/li\u003e\n\u003cli\u003eEpoxy-sealed relays with arc suppressors (250 Vrms)\u003c\/li\u003e\n\u003cli\u003eRelay life up to 10,000 cycles\u003c\/li\u003e\n\u003cli\u003eLow current gold-plated contact option for 1 mA @ 1 Vdc minimum load\u003c\/li\u003e\n\u003cli\u003eCompatible with 3500 Rack Configuration Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial machinery monitoring and protection\u003c\/li\u003e\n\u003cli\u003eProcess automation alarm outputs\u003c\/li\u003e\n\u003cli\u003eHazardous area relay interfacing\u003c\/li\u003e\n\u003cli\u003eIntegration with PLC, DCS, SIS, TSI systems\u003c\/li\u003e\n\u003cli\u003eLow-current signal switching in control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/33-04-00: Complete 16-Channel Relay Module Assembly\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifies the pre-configured combination consisting of the front main module card and the rear low-current failsafe output board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04: Output Module Type Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLow Current 16-Channel Failsafe Relay Output Module featuring gold-plated contacts (Rear I\/O Module Spare: \u003cstrong\u003e149992-04\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Hazardous Area Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo hazardous area agency approvals or certifications required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpares \u0026amp; Accessories\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number \u003cstrong\u003e149992-04\u003c\/strong\u003e: Spare 16-Channel Low Current Failsafe Relay Output Module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMain module: 0.7 kg (1.6 lb), I\/O module: 0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMain module: 241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in), I\/O module: 241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003eMain: 1 full-height front slot, I\/O: 1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSPDT (Single-pole Double-throw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Arc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003eStandard: 100 mA @ 5 Vdc, Low Current: 1 mA @ 1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003eDC: 5 A, AC: 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Power\u003c\/td\u003e\n\u003ctd\u003eDC: 70 W @ 24 Vdc, AC: 1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003eDC: 125 Vdc, AC: 250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eOK, TX\/RX, CH Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/D-Agent_1-_work-77-s-Upload-162096J1.pdf?v=1780026391\"\u003eRefer to 3500 rack manual\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay outputs, power, communication connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eGrounding and Shielding\u003c\/h4\u003e\n\u003cp\u003eEnsure the rack frame is properly tied to the plant instrumentation ground before inserting modules. Field wiring shields should be terminated at the designated shield terminals on the I\/O module to minimize electromagnetic interference and ensure signal integrity.\u003c\/p\u003e\n\u003ch4\u003eHazardous Area Precautions\u003c\/h4\u003e\n\u003cp\u003eDo not disconnect field wiring or module connections while the circuit is live unless the location is verified to be non-hazardous. Live handling in explosive atmospheres can result in arc-induced ignition risks.\u003c\/p\u003e\n\u003ch4\u003eModule Placement\u003c\/h4\u003e\n\u003cp\u003eAlign the main module with the chosen front slot to the right of the TDI module. Slide it firmly into the backplane connectors and tighten the panel screws. Install the matching I\/O module in the corresponding slot directly on the rear of the rack assembly.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 04 option signify in this module part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e The 04 code specifies that this is the Low Current 16-Channel Failsafe variant equipped with gold-plated contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum current rating for the gold-plated contact version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum switched current rating is 1 mA @ 1 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix the configuration for Normally Energized and Normally De-energized modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the sixteen channels are split into four distinct groups of four channels, and each group is independently switch-selectable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the TX\/RX LED on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TX\/RX LED flashes to indicate active transmission and reception of communication data between this module and other rack modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware package contain built-in spark protection for the contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, an internal 250 Vrms epoxy-sealed relay arc suppressor is standard equipment on the hardware channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit process individual variables from multiple monitor modules at once?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the Alarm Drive Logic can combine Alert, Danger, or Not-OK inputs from any monitor channel or combination of monitor channels within the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software tool is required to configure the voting logic pathways?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system logic is engineered and uploaded using the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the relay operation if the module encounters an internal failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Failsafe design ensures that when a major failure or loss of control occurs, the relays drop to their safe de-energized or default state depending on wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to exceed 5 mA when using an AC supply voltage up to 120Vac?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, currents exceeding 5 mA on these low-current gold relays will degrade or permanently damage the contact plating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many slots does the complete main and I\/O assembly take up?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt occupies one full-height slot on the front of the rack and one corresponding full-height slot on the rear panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I plug this module into the slot immediately adjacent to the power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt must be placed in any available slot situated to the right of the Transient Data Interface module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a solid light on the OK LED indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA solid light confirms that the hardware is powered up, has passed initial self-tests, and is operating properly.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848837995,"sku":"3500\/33-04-00 149992-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-04-00-149992-04-relay-i-o-module-fkulr4tcehu_c36c9898-9ec7-4d81-a6b1-b3299e531e38.jpg?v=1765448997"},{"product_id":"bently-nevada-3500-60-05-01-136711-01-rtd-tc-temperature-monitor","title":"Monitor temperatury Bently Nevada 3500\/60-05-01 136711-01 RTD\/TC","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e3500\/60-05-01 (136711-01)\u003c\/strong\u003e\u003c\/span\u003e to moduł monitorowania temperatury o wysokiej precyzji, zaprojektowany dla systemu ochrony maszyn Bently Nevada 3500. Ta konkretna konfiguracja zawiera nieizolowany moduł I\/O z wewnętrznymi barierami i wewnętrznymi zakończeniami, zapewniając kompaktowy i bezpieczny interfejs dla krytycznych punktów pomiaru temperatury maszyn. Głównie wykorzystywany w energetyce, przetwórstwie węglowodorów oraz dużych systemach sprężania, \u003cspan\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003c\/span\u003e przyjmuje sygnały z maksymalnie sześciu czujników temperatury RTD lub termopar (TC). Integrując monitorowanie temperatury bezpośrednio w szafie ochrony maszyn, umożliwia płynne powiązanie danych drgań i temperatury. Ta integracja jest kluczowa dla wczesnego wykrywania degradacji łożysk lub awarii systemów chłodzenia, co znacząco zmniejsza ryzyko katastrofalnych uszkodzeń urządzeń i nieplanowanych przestojów w ciężkich warunkach przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eRozbicie sufiksu\u003c\/h3\u003e\n\u003cp\u003eNomenklatura modelu \u003cspan\u003e\u003cstrong\u003e3500\/60-05-01\u003c\/strong\u003e\u003c\/span\u003e oznacza konkretną konfigurację sprzętową zoptymalizowaną pod kątem bezpieczeństwa i łączności w strefach zagrożenia:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/60:\u003c\/strong\u003e oznaczenie serii modułu monitorowania temperatury RTD\/TC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA: 05 (Typ modułu I\/O):\u003c\/strong\u003e nieizolowany moduł I\/O RTD\/TC wyposażony wewnętrzne bariery. Ta opcja jest przeznaczona do zastosowań, gdzie czujniki terenowe znajdują się w strefach zagrożenia, wykorzystując wewnętrzne bariery bezpieczeństwa do ograniczenia poziomu energii.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB: 01 (Certyfikat agencji):\u003c\/strong\u003e certyfikat CSA\/NRTL\/C (Klasa 1, Podział 2) zgodny z normami bezpieczeństwa Ameryki Północnej dla stref zagrożenia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e136711-01:\u003c\/strong\u003e numer części tylnego modułu I\/O odpowiadający funkcji wewnętrznego zakończenia i bariery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/60-05-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumer części I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e136711-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSygnały wejściowe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 do 6 kanałów RTD lub TC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 MΩ na przewód\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eObsługa RTD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatyna 100 Ohm (3\/4 przewody), Nikiel 120 Ohm, Miedź 10 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eObsługa TC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTyp E, J, K, T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 Watów nominalnie\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDokładność (wewnętrzne zakończenie)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 3°C przy 25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C do +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga modułu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,91 kg (monitor), 0,46 kg (I\/O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary (monitor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eZapytania terenowe i FAQ wsparcia\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCzy mogę mieszać typy RTD i termopar na tym samym module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3500\/60 pozwala na indywidualną konfigurację kanałów za pomocą oprogramowania. Jednak typ sprzętowego modułu I\/O (wewnętrzna bariera vs. izolowany) musi być spójny dla całego modułu. Platyna 100 Ohm (0,00385 alfa) jest zalecana jako przemysłowy standard dokładności.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo się stanie, jeśli przewód terenowy się zwarzy lub przerwie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł posiada diodę LED OK oraz autodiagnostykę. Jeśli sygnał przetwornika wyjdzie poza zakres lub przewód zostanie przerwany, dioda OK zgaśnie, a dioda Tx\/Rx wskaże status, zapobiegając fałszywym alarmom i jednocześnie informując operatorów.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDlaczego zakres pełnoskalowy jest zmniejszony dla termopar typu E powyżej 35°C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eW izolowanych konfiguracjach I\/O przy podwyższonych temperaturach otoczenia dryft termiczny może wpływać na liniowość niskiego zakresu. Dla nieizolowanej opcji 05 dokładność pozostaje stała w określonym zakresie pracy od 0 do 65°C.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWytyczne instalacyjne i porady inżynierskie\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegralność stref zagrożenia:\u003c\/strong\u003e podczas korzystania z modułu I\/O 136711-01 z wewnętrznymi barierami, upewnij się, że praktyki okablowania terenowego ściśle odpowiadają schematom kontrolnym dla Klasy 1, Podział 2. Wewnętrzne bariery mają na celu ograniczenie energii, ale niewłaściwe uziemienie lub ominięcie tych zacisków może naruszyć ocenę bezpieczeństwa całej szafy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTrasa wewnętrznego zakończenia:\u003c\/strong\u003e stosuj wysokiej jakości ekranowane skręcone pary przewodów dla przewodów TC i RTD. Ponieważ jest to moduł z wewnętrznym zakończeniem (IT), upewnij się, że ekrany kabli są uziemione wyłącznie do zacisku uziemienia szafy 3500. Unikaj uziemienia wielopunktowego, aby zapobiec pętlom masy, które wprowadzają szumy do obwodów temperatury o wysokiej impedancji.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKompensacja zimnego złącza (CJC):\u003c\/strong\u003e dla zastosowań z termoparami czujnik CJC znajduje się na zaciskach modułu I\/O. Aby zapewnić maksymalną dokładność, unikaj instalowania urządzeń generujących ciepło (np. dużych zasilaczy) bezpośrednio pod tyłem szafy 3500, ponieważ lokalne nagrzewanie modułu I\/O może wprowadzać przesunięcia pomiarowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWymagania dotyczące slotów:\u003c\/strong\u003e monitor 3500\/60 wymaga jednego pełnowymiarowego slotu z przodu, a moduł I\/O 136711-01 odpowiadającego pełnowymiarowego slotu z tyłu. Upewnij się, że moduł jest całkowicie osadzony, a śruby motylkowe dokręcone ręcznie, aby zachować integralność komunikacji z płytą tylnią.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850017643,"sku":"3500\/60-05-01  136711-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-60-01-05-136711-01-rtd-tc-i-o-module-with-internal-barriers-and-internal-terminations-j5xg1sobbwu_320b72c3-d4ac-4bca-9af8-9b4035d1ad54.jpg?v=1765449017"},{"product_id":"bently-nevada-3500-20-02-02-00-125744-01-tmr-rack-interface-module","title":"Moduł interfejsu szafy Bently Nevada 3500\/20-02-02-00 125744-01 TMR","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModuł interfejsu szafy (RIM)\u003c\/strong\u003e pełni rolę głównej bramy i interfejsu przetwarzania dla systemu ochrony maszyn \u003cstrong\u003eserii 3500\u003c\/strong\u003e. Ustanawia połączenie za pomocą własnego protokołu, umożliwiając kompleksową konfigurację szafy oraz pobieranie danych maszyn w czasie rzeczywistym. Zaprojektowany wyłącznie do lokalnego śledzenia układu, moduł ten musi znajdować się w slocie 1 zespołu szafy, bezpośrednio obok zasilaczy systemu.\u003c\/p\u003e\n\u003cp\u003eTa konkretna konfiguracja \u003cstrong\u003e3500\/20-02-02-00\u003c\/strong\u003e działa jako wersja potrójnie modularnie redundantna (\u003cstrong\u003eTMR\u003c\/strong\u003e) wyposażona w dedykowany interfejs szeregowy \u003cstrong\u003eRS232\/RS422\u003c\/strong\u003e. Poza standardowym zarządzaniem komunikacją, architektura \u003cstrong\u003eTMR\u003c\/strong\u003e wykonuje ciągłe \u003cstrong\u003eporównanie kanałów monitorujących\u003c\/strong\u003e oraz logikę głosowania monitorów, krzyżowo sprawdzając wyniki trzech redundantnych monitorów. Jeśli różnica wyjść przekroczy wstępnie skonfigurowane limity procentowe, moduł oznacza odpowiedni monitor jako uszkodzony i rejestruje odrębny wpis w Systemowej Liście Zdarzeń. Choć jednostka obsługuje kluczowe funkcje całej szafy, pozostaje oddzielona od krytycznej ścieżki monitorowania maszyn, zapewniając, że jej działanie nie wpływa negatywnie na normalne, ciągłe pętle ochrony bezpieczeństwa.\u003c\/p\u003e\n\u003ch3\u003eFunkcje\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorównanie kanałów monitorujących:\u003c\/strong\u003e Dynamicznie porównuje i przetwarza dane diagnostyczne z trzech redundantnych kart monitorujących, aby utrzymać integralność głosowania systemu TMR.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePodwójna komunikacja szeregowa:\u003c\/strong\u003e Wykorzystuje wszechstronny moduł I\/O z tyłu, obsługujący zarówno protokoły RS232, jak i RS422 za pomocą zintegrowanego przełącznika sprzętowego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKompleksowe diody diagnostyczne:\u003c\/strong\u003e Zapewniają wizualizację statusu na przednim panelu za pomocą dedykowanych wskaźników dla stanu modułu, aktywności komunikacji, statusu Trip Multiply oraz ważności konfiguracji.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSprzętowy klucz konfiguracji:\u003c\/strong\u003e Zawiera fizyczny przełącznik na przednim panelu, który zabezpiecza szafę w trybie RUN przed nieautoryzowanymi zdalnymi lub lokalnymi modyfikacjami lub umożliwia zmiany w trybie PROGRAM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystemowe wejścia kontaktowe:\u003c\/strong\u003e Zawiera dyskretne wejścia suchego styku do obsługi sterowania systemowego, w tym zdalne wyłączanie alarmu, reset szafy oraz wyzwalanie mnożnika Trip Multiply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUkłady bezpieczeństwa i ochrony maszyn z potrójną redundancją modułową (TMR).\u003c\/li\u003e\n\u003cli\u003eCiągłe monitorowanie stanu i przesyłanie danych diagnostycznych dla krytycznych obrotowych zasobów przemysłowych.\u003c\/li\u003e\n\u003cli\u003eRozproszone sieci instrumentacji wieloszafowej turbomaszyn wymagające łańcuchowych interfejsów szeregowych hosta.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod modelu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł interfejsu rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTyp interfejsu rack: TMR RIM (Używać tylko w aplikacjach wymagających konfiguracji potrójnej redundancji modułowej)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTyp modułu I\/O: moduł I\/O z interfejsem RS232\/RS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: Brak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eUwaga:\u003c\/strong\u003e Numer części zamiennej pojedynczego komponentu reprezentującego główną kartę modułu interfejsu TMR Rack to \u003cstrong\u003e125744-01\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.5522%;\"\u003e\u003cstrong\u003eKategoria\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 21.8794%;\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 54.0343%;\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e\u003cstrong\u003eElektryczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eZużycie energii\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eTypowo 4,75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eMaksymalny prąd (styki)\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e\u003c1 mA DC, suchy styk do wspólnego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e\u003cstrong\u003eWejścia\/wyjścia i przekaźnik\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eTyp przekaźnika OK\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eNormalnie załączony, użytkownik może wybrać styk otwarty lub zamknięty dla sygnalizacji stanu Nie OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eParametry przekaźnika\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e5A przy 24 V DC \/ 120 V AC, 120 W \/ 600 VA przełączanej mocy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eTłumienie łuku\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eDostarczane na stykach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e\u003cstrong\u003eKomunikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003ePort na panelu przednim\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eTylko RS232, własny protokół Bently Nevada, maksymalna prędkość 38,4 k baud (z funkcją auto-baud), maksymalna długość kabla 30 metrów (100 stóp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003ePorty szeregowe modułu I\/O\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eRS232 \/ RS422, własny protokół Bently Nevada, maksymalna prędkość 38,4 k baud (z funkcją auto-baud)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eDługość kabla RS232\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eMaksymalnie 30 metrów (100 stóp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eDługość kabla RS422\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eMaksymalnie 1200 metrów (4000 stóp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003ePort łańcuchowy (Daisy-Chain)\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eTylko RS422, własny protokół Bently Nevada, maksymalna prędkość 38,4 k baud, maksymalna odległość 1200 metrów (4000 stóp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e\u003cstrong\u003eŚrodowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e-30 stopni Celsjusza do +65 stopni Celsjusza (-22 stopni Fahrenheita do +150 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e-40 stopni Celsjusza do +85 stopni Celsjusza (-40 stopni Fahrenheita do +185 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eWilgotność\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e\u003cstrong\u003eMechaniczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eWymiary modułu RIM\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e241,3 mm x 24,4 mm x 241,8 mm (9,5 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eWaga modułu RIM\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e0,91 kg (2,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eWymiary wejścia\/wyjścia RS232\/RS422\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eWaga modułu I\/O RS232\/RS422\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e0,45 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eŁączna waga\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e1,36 kg (3,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eWymagania dotyczące przestrzeni\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003e1 pełnowymiarowy przedni slot (płyta główna) i 1 pełnowymiarowy tylny slot (moduł I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eProducent\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eBently Nevada (firma Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5522%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 21.8794%;\"\u003eKraj pochodzenia\u003c\/td\u003e\n\u003ctd style=\"width: 54.0343%;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział slotów:\u003c\/strong\u003e Zamontuj główną kartę procesora wyłącznie w slocie 1 po lewej stronie przedniej obudowy, bezpośrednio obok modułów zasilania systemu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyrównanie tylnych wejść\/wyjść:\u003c\/strong\u003e Zainstaluj odpowiedni moduł I\/O RS232\/RS422 w pasującym pełnowymiarowym tylnym slocie bezpośrednio za przednim modułem procesora.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWybór protokołu:\u003c\/strong\u003e Ustaw wbudowany tylny przełącznik suwakowy na pozycję RS232 lub RS422 w zależności od fizycznej konfiguracji interfejsu komputera nadrzędnego lub konwertera.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdresowanie szafy:\u003c\/strong\u003e Użyj zintegrowanego przełącznika adresu sprzętowego, aby zdefiniować unikalny kod identyfikacyjny obudowy podczas instalacji wielu szaf w pętli sieciowej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzedłużenia okablowania:\u003c\/strong\u003e Nie przekraczaj 30 metrów dla połączeń RS232 ani 1200 metrów dla połączeń RS422, aby uniknąć utraty pakietów danych szeregowych lub pogorszenia sygnału.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest funkcjonalna różnica między standardowym RIM a RIM TMR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWersja standardowa obsługuje konfigurację i trasowanie komunikacji dla standardowych szaf. Wariant TMR dodaje specyficzne algorytmy porównawcze sprzętu, które ciągle oceniają wyjścia z trzech różnych monitorów, aby wdrożyć logikę głosowania błędów.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy awaria lub usunięcie tego modułu przerwie aktywną pętlę ochrony wyłącznika maszyny?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie. Ten moduł obsługuje konfigurację infrastruktury szafy, komunikację i systemowe logowanie, ale nie znajduje się w krytycznej ścieżce monitorowania bezpieczeństwa i nie wpływa na działanie poszczególnych monitorów.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak mogę ograniczyć nieautoryzowanym użytkownikom możliwość zdalnej zmiany ustawień ochrony maszyn?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrzekręć kluczyk konfiguracyjny na panelu przednim do pozycji RUN i wyjmij fizyczny klucz. To zablokuje zdalne i lokalne programowanie, zapobiegając modyfikacjom aktywnych progów operacyjnych.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850083179,"sku":"3500\/20-02-02-00 125744-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-20-02-02-00-125744-01-tmr-rack-interface-module-aec5lyikuok_c778fd01-27c0-4e0c-8b0f-0b33dce71161.jpg?v=1765449018"},{"product_id":"bently-nevada-3500-32m-149986-02-4-channel-relay-module","title":"Bently Nevada 3500\/32M 149986-02 4-Channel Relay Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/32M\u003c\/strong\u003e with spare part number \u003cstrong\u003e149986-02\u003c\/strong\u003e is a full-height module that delivers four highly configurable relay outputs for auto-trip execution and interlocking machinery protection. This \u003cstrong\u003e3500\/32M 149986-02\u003c\/strong\u003e module populates any designated slot located to the right of the Transient Data Interface (TDI) module inside a standard 3500 rack. Each relay output operates independently and can be programmed with sophisticated Alarm Drive Logic, integrating complex AND\/OR voting logic combinations that evaluate Alert, Danger, Not-OK, and individual Proprietary Logic (PPL) variables sourced from any channel or group of channels across the protection chassis via the configuration utility.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour fully independent single-pole double-throw (SPDT) relay channels.\u003c\/li\u003e\n\u003cli\u003eCustom voting configurations utilizing comprehensive onboard Alarm Drive Logic functions.\u003c\/li\u003e\n\u003cli\u003eFactory-installed 250 Vrms arc suppressors on each channel as a standard build feature.\u003c\/li\u003e\n\u003cli\u003eHardware-switch-selectable operations allowing independent Normally De-energized or Normally Energized assignments.\u003c\/li\u003e\n\u003cli\u003eFront panel status tracking via distinct OK, TX\/RX, and individual CH ALARM LEDs.\u003c\/li\u003e\n\u003cli\u003eSealed contact assemblies featuring epoxy protection barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency machinery shutdown loop initiation for industrial rotating equipment.\u003c\/li\u003e\n\u003cli\u003eFunctional safety (SIL) machine trip systems.\u003c\/li\u003e\n\u003cli\u003eCritical multi-channel voting interlock setups for high-speed gas or steam turbines.\u003c\/li\u003e\n\u003cli\u003eHazardous zone status annunciator signaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpare Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e149986-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel Relay Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, double-throw (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArc Suppression\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms installed as standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Life Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles @ 5 A, 24 Vdc or 240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Minimum Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard DC Contact Rating (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 0V to 30 Vdc, 0.75 A @ 48 Vdc, 0.2 A @ 125 Vdc (125 Vdc max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard AC Contact Rating (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 250 Vac max (450 VA max switched power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\/Hazardous Minimum Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\/Hazardous DC Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 0V to 30 Vdc (30 Vdc maximum switched voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\/Hazardous AC Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 30 Vac maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 242 mm (9.50 in. x 0.96 in. x 9.52 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in. x 0.96 in. x 3.90 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Space Allocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot (Main), 1 full-height rear slot (I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Selection:\u003c\/strong\u003e Slide the full-height front module into any available user slot located to the right of the Transient Data Interface (TDI) module inside the 3500 chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Connection Assembly:\u003c\/strong\u003e Align and seat the matching 4-channel relay I\/O module in the corresponding full-height rear slot directly behind the main control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Operating Setup:\u003c\/strong\u003e Adjust the onboard physical switches to define the baseline state as Normally De-energized (ND) or Normally Energized (NE) for each individual channel before field wiring is tied in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Retention:\u003c\/strong\u003e Secure the front-panel panel fasteners fully to ground the module housing properly to the chassis structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Integration:\u003c\/strong\u003e Establish connection parameters, input tracking channels, and custom AND\/OR structures using the 3500 Rack Configuration Software prior to going live.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Precautions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Restriction Compliance:\u003c\/strong\u003e When used in systems ordered with hazardous area approvals (Division 2\/Zone 2 certified), the relay voltages must be strictly restricted to a maximum of 30 Vdc or 30 Vac. The module layout does not support standard increased physical spacing rules required for higher operating voltages under these certifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety (SIL) Limit:\u003c\/strong\u003e If integrated as a component within an active functional safety (SIL) loop, higher voltages are strictly prohibited. The functional safety certificate mandates adherence to the limited voltage levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Shock Hazard:\u003c\/strong\u003e Isolate all external field wiring and circuits prior to working on terminal strips. This module can expose conductors to potential contact, introducing severe electrical burn or shock hazards under high-voltage configurations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850345323,"sku":"3500\/32M 149986-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-32m-149986-02-4-channel-relay-module-jpukccfwkaz_1a867c4f-eb20-4adb-ab0a-439738ac47ac.jpg?v=1765449025"},{"product_id":"bently-nevada-3500-15-04-04-01-133300-01-legacy-low-voltage-dc-power-input-module","title":"Moduł wejściowy niskiego napięcia DC Bently Nevada 3500\/15-04-04-01 133300-01 Legacy","description":"\u003cp style=\"color: #2d3748;\"\u003e\u003cstrong\u003eBently Nevada 3500\/15-04-04-01\u003c\/strong\u003e, działający w ścisłej współpracy z tylnym interfejsem \u003cstrong\u003e133300-01\u003c\/strong\u003e, to przemysłowy półwysokościowy moduł konwersji zasilania zaprojektowany dla systemu ochrony maszyn serii 3500. Ta specyficzna kombinacja sprzętowa tworzy legacy infrastrukturę wejściową niskonapięciowego prądu stałego, odbierając surowe wektory zasilania zakładowego i wykonując wysoką izolację oraz regulację obniżającą napięcie, aby zasilać wewnętrzne pasywne szyny backplane z ściśle monitorowanymi potencjałami operacyjnymi DC.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eKluczowe cechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePrawdziwa topologia redundantna N+1:\u003c\/strong\u003e Wspiera ciągłe przydzielanie podwójnego zasilania w pojedynczej konfiguracji szafy, gdzie dolna zatoka działa jako główne źródło zasilania, a górna jako nieprzerwana jednostka zapasowa na gorąco.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMożliwość wymiany na gorąco bez przestojów:\u003c\/strong\u003e Wewnętrzne obwody dynamicznego wyrównania pozwalają na fizyczne usunięcie lub włożenie dowolnej karty zasilania, podczas gdy szafa monitorująca maszyny pozostaje w pełni zasilana, zapobiegając fałszywym wyłączeniom lub martwym strefom ochrony.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBariera izolacji galwanicznej:\u003c\/strong\u003e Zaprojektowana z mocno oddzielonymi ścieżkami obwodów między zaciskami wejściowymi a połączeniami backplane, aby pochłaniać duże przepięcia napięciowe po stronie pola i fluktuacje pętli masy.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedykowany moduł wejściowy zasilania (PIM):\u003c\/strong\u003e Sparowany z tylnym modułem legacy 133300-01 wyposażonym w solidne bloki zaciskowe i zoptymalizowane filtry wejściowe dedykowane niskonapięciowym bankom baterii.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eKrytyczna ochrona turbin maszynowych:\u003c\/strong\u003e Dostarcza stabilne szyny operacyjne dla krytycznych modułów monitorowania drgań wału, pozycji osi i prędkości w zespołach turbin parowych i gazowych.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIntegracja z bankiem baterii zakładowych:\u003c\/strong\u003e Bezpośrednie połączenie z centralnymi przemysłowymi systemami zasilania awaryjnego 24V DC w zakładach wytwarzania energii i przetwórstwa petrochemicznego.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSzafy sterownicze o wysokiej dostępności:\u003c\/strong\u003e Wdrożenie w zdalnych obudowach maszyn wymagających maksymalnej dostępności systemu dzięki redundantnemu zasilaniu instrumentów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eKod opcji\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eSzczegóły wyboru inżynieryjnego\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003eKonfiguracja bazowa 3500\/15-AA-BB-CC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eAA - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZasilacz niskonapięciowy DC Legacy (zakres 20 do 30 Vdc)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eBB - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł wejściowy niskonapięciowego zasilania stałoprądowego (PIM) Legacy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eCC - 01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOpcja zatwierdzenia agencji: CSA-c-US (Klasa I, Podział 2, Grupy A, B, C, D)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003eNumery części rozbicia komponentów\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e106M1081-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZespół głównej karty zasilacza niskonapięciowego DC Legacy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e133300-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł wejściowy niskonapięciowego zasilania stałoprądowego (PIM) tylny sprzęt\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eParametr techniczny\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eZweryfikowana wartość inżynieryjna\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres napięcia wejściowego\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZakres napięcia wejściowego 20 V DC do 30 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaksymalny prąd wejściowy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10,0 A ciągłego prądu\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTypowe zużycie energii\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMaksymalna moc 230 W przy pełnym obciążeniu obudowy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRegulowane szyny wyjściowe\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+5 V DC, -5 V DC, +15 V DC, -15 V DC rozprowadzane przez pasywną płytę tylną\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWytrzymałość dielektryczna izolacji\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRezystancja izolacji terminalu 500 V DC do uziemienia obudowy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRozmiar formatu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUkład karty o połowie wysokości (zajmuje określone lewe sloty w stojaku)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres temperatury pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 stopni Celsjusza do +65 stopni Celsjusza\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres temperatury przechowywania\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 stopni Celsjusza do +85 stopni Celsjusza\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres wilgotności względnej\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDo 95% wilgotności względnej, bez kondensacji\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMonitorowanie stanu na panelu przednim\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZintegrowana zielona matryca diod LED „Supply OK”\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (firma Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStany Zjednoczone\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga głównej karty zasilającej\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0,77 kg (1,70 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga tylnej karty wejściowej PIM\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0,31 kg (0,68 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCałkowita waga netto systemu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1,08 kg (2,38 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1,55 kg (kompletny system z podwójną kartą w pudełku)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWymiary opakowania (obliczone)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e285 mm x 210 mm x 155 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eOznaczenie zacisku\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003ePrzypisanie interfejsu obwodu\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDodatnia linia wejściowa DC (akceptuje napięcie odniesienia +20 do +30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUjemna linia powrotna DC (wspólna ścieżka powrotna obwodu zasilania)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eGND\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePołączenie uziemienia ochronnego (bezpośrednie połączenie metalowej ramy)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e Odizoluj główny wyłącznik obwodu zasilania 24V DC przed rozpoczęciem instalacji. Nie manipuluj ani nie podłączaj bezpośrednio przewodów zasilających do tylnego bloku zaciskowego 133300-01 pod napięciem. Mostkowanie przewodów pod napięciem grozi ciągłym powstawaniem łuku elektrycznego, wewnętrznymi zwarciami między warstwami miedzi oraz trwałą awarią wszystkich kart monitorujących na wspólnej płycie tylnej.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePodłącz zweryfikowaną antystatyczną opaskę na nadgarstek do niepomalowanej ramy stojaka, aby rozładować potencjalne ładunki elektrostatyczne przed otwarciem osłon modułów.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePłynnie wsunąć główną kartę zasilającą o połowie wysokości w dedykowane prowadnice na przedniej lewej stronie obudowy 3500, aż do połączenia z zespołem pinów tylnej płyty.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWyrównaj starą kartę zasilającą 133300-01 w równoległej tylnej zatoce. Dokładnie dokręć tylne śruby mocujące, aby zabezpieczyć jednostkę przed trwałymi wibracjami mechanicznymi.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eOdsłoń kable zasilające o 7 milimetrów, mocno włóż je do zacisku terminala DC, dopasowując do zweryfikowanych biegunowości, i dokręć śruby zaciskowe zgodnie ze specyfikacją momentu obrotowego.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850673003,"sku":"3500\/15-04-04-01 133300-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-04-04-01-133300-01-low-voltage-dc-power-input-module-jkcdk13hega_bc249377-abc5-4e7b-890f-e8d2efa9342f.jpg?v=1765449036"},{"product_id":"bently-nevada-3500-44-02-00-126623-01-aero-gt-vibration-monitor","title":"Monitor drgań Bently Nevada 3500\/44-02-00 126623-01 Aero GT","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eMonitor drgań Aeroderivative GT \u003cstrong\u003e3500\/44M\u003c\/strong\u003e to czterokanałowy moduł zaprojektowany do ciągłej ochrony i monitorowania maszyn w zastosowaniach z aeroderiwatywnymi turbinami gazowymi. Przetwarza sygnały z przetworników prędkości, akcelerometrów i czujników Velomitor, aby ocenić stan zasobów i chronić kluczowe maszyny poprzez porównanie monitorowanych parametrów z skonfigurowanymi progami alarmowymi. Monitor ten łączy się ze standardowymi zewnętrznymi blokami zakończeniowymi za pomocą modułu I\/O Aero GT \u003cstrong\u003e126623-01\u003c\/strong\u003e oraz strukturalnych wiązek kablowych. Akceptuje sygnały z dwóch niezależnych źródeł \u003cstrong\u003eKeyphasor\u003c\/strong\u003e, co pozwala każdej parze kanałów na przetwarzanie różnych filtrów śledzących. Dostarczając wartości proporcjonalne w czasie rzeczywistym oraz niezbędne dane maszynowe, stanowi kluczowy element dla operacji przemysłowych i personelu utrzymania ruchu.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCzterokanałowy ciągły system ochrony maszyn dostosowany do aeroderiwatywnych turbin gazowych.\u003c\/li\u003e\n\u003cli\u003eObsługuje wiele opcji filtrowania, w tym integrację sygnału, \u003cstrong\u003eśledzenie drgań 1X\u003c\/strong\u003e oraz pasmowo-przepustowe drgania.\u003c\/li\u003e\n\u003cli\u003ePodwójne wejścia \u003cstrong\u003eKeyphasor\u003c\/strong\u003e umożliwiające odrębne filtry śledzące na oddzielnych parach kanałów.\u003c\/li\u003e\n\u003cli\u003eMożliwość konfiguracji potrójnej redundancji modułowej (\u003cstrong\u003eTMR\u003c\/strong\u003e) wykorzystującej architektury głosowania eliminujące pojedyncze punkty awarii.\u003c\/li\u003e\n\u003cli\u003eKonfiguracje kanałów multimodalnych obsługujące do ośmiu zestawów odrębnych parametrów alarmowych dopasowanych do konkretnych trybów maszyny.\u003c\/li\u003e\n\u003cli\u003eWskaźniki LED na panelu przednim informujące o stanie pracy modułu, ruchu komunikacji i stanach obejścia.\u003c\/li\u003e\n\u003cli\u003eWyjścia przetworników buforowanych współosiowo na panelu przednim dla bezpiecznego, zabezpieczonego przed zwarciem diagnozowania.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nAeroderiwatywne turbiny gazowe \u003cstrong\u003eRolls Royce\u003c\/strong\u003e: RB211 i Avon.\u003c\/li\u003e\n\u003cli\u003e\nAeroderiwatywne turbiny gazowe \u003cstrong\u003eGeneral Electric\u003c\/strong\u003e: LM1600, LM2500, LM5000 i LM6000.\u003c\/li\u003e\n\u003cli\u003e\nTurbiny gazowe \u003cstrong\u003eUnited Technologies\u003c\/strong\u003e Turbo Power: GG3, G44, FT4 i FT8.\u003c\/li\u003e\n\u003cli\u003eElektrownie, instalacje napędu mechanicznego oraz platformy wiertnicze na morzu wykorzystujące aeroderiwatywne turbiny gazowe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod zamówienia \/ Numer części\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/44-A02-B00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKompletny zestaw monitora aeroderivatywnego z zewnętrznymi zakończeniami (bez zatwierdzeń agencji).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja modułu I\/O Aero GT z zewnętrznymi zakończeniami.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: Brak.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e126623-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzęści zamienne:\u003c\/strong\u003e Moduł I\/O Aero GT z zewnętrznymi zakończeniami.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKategoria parametru\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Monitorowanie stanu zasobów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/44-02-00 (3500\/44M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 7,7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O: powyżej 95 kOhm; Prox\/Velom I\/O: 10 kOhm dla Prox\/Accel, 3,5 MOhm dla Velomitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzułość Aeroderivative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,94 mV\/(mm\/s) (100 mV\/(in\/s)) lub 5,71 mV\/(mm\/s) (145 mV\/(in\/s))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjście rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 do +20 mA proporcjonalnie do pełnej skali monitora; rezystancja obciążenia 0 do 600 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRozdzielczość wyjścia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,3662 uA na bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBłąd +\/-0,25% w temperaturze pokojowej, +\/-0,7% w zakresie temperatur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęstotliwość aktualizacji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms lub mniej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wyjścia buforowanego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePasmo przenoszenia (bezpośrednie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAeroderivative: 4 Hz do 5500 Hz (-3 dB); Aeroderivative2\/Multimode: 4 Hz do 30 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePasmo przenoszenia (zintegrowane)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrędkość: 18 Hz do 5500 Hz (-3 dB); Przyspieszenie: 18 Hz do 14 500 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres filtra śledzącego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObowiązuje dla prędkości maszyn od 60 do 240 000 cpm (lub do 300 000 cpm dla Aeroderivative2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność alarmu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach 0,13% wartości docelowej; regulowana od 0 do 100% pełnej skali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg (2,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,45 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania przestrzenne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowy przedni slot dla modułu głównego, 1 pełnowymiarowy tylny slot dla modułu I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cp\u003ePanel przedni i tylny \u003cstrong\u003emoduł I\/O Aero GT\u003c\/strong\u003e z zewnętrznymi zakończeniami umożliwiają specyficzne interfejsy fizyczne:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eElement interfejsu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis \/ Funkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrzednie złącza koncentryczne (1-4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJedno dedykowane buforowane wyjście przetwornika dla każdego kanału, zabezpieczone przed zwarciem.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTylne złącze przetworników D-Sub\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGłówne wielopinowe złącze do kierowania sygnałów z czujników do zewnętrznych bloków zakończenia.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTylne wyjścia rejestratora D-Sub\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterfejs do podłączenia zewnętrznego bloku zakończenia rejestratora za pomocą kabla.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda OK \/ TX\/RX \/ obejście\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzednie wskaźniki statusu pokazujące stan działania, komunikację szafy i tryb obejścia.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział slotów:\u003c\/strong\u003e Zainstaluj główny moduł monitora w pojedynczym slocie pełnowymiarowym z przodu \u003cstrong\u003eszafy 3500\u003c\/strong\u003e i wyrównaj odpowiadający mu zewnętrzny moduł zakończenia I\/O w pasującym slocie z tyłu, bezpośrednio za nim.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrupowanie TMR:\u003c\/strong\u003e Dla konfiguracji potrójnej modularnej redundancji, zainstaluj trzy monitory aeroderivative obok siebie w grupach po trzy, aby umożliwić głosowanie systemowe na poziomie sprzętowym.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOkablowanie:\u003c\/strong\u003e Użyj kabla sygnałowego \u003cstrong\u003e129525\u003c\/strong\u003e do połączenia zewnętrznego modułu I\/O zakończenia z wyznaczonym blokiem zakończeniowym. Upewnij się, że długość kabla odpowiada ograniczeniom fizycznym obudowy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWersja oprogramowania:\u003c\/strong\u003e Użyj \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e w wersji 2.50 lub nowszej dla standardowych konfiguracji aeroderivative, lub wersji 3.3 lub wyższej dla zaawansowanych konfiguracji multimode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuforowane wyjścia:\u003c\/strong\u003e Przednie gniazda koncentryczne mogą być bezpośrednio podłączone do oscyloskopu lub analizatora bez przerywania podstawowej pracy monitora, dzięki wbudowanej ochronie przed zwarciem 550 Ohm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e EN61000-6-4 emisje promieniowane, EN 55011 klasa A emisje przewodzone i promieniowane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy odporności:\u003c\/strong\u003e EN61000-6-2, EN61000-4-2 (kryteria ESD B), EN61000-4-3 (kryteria odporności na promieniowanie A), EN61000-4-4 (kryteria EFT B), EN61000-4-5 (kryteria przepięć B), EN61000-4-6 (kryteria odporności przewodzonej A), EN61000-4-8 (pole magnetyczne), EN61000-4-11 (spadki napięcia).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa niskonapięciowa:\u003c\/strong\u003e Wymagania bezpieczeństwa EN61010-1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJakie typy czujników można podłączyć do tej konkretnej konfiguracji monitora?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł I\/O Aero GT łączy się bezpośrednio z przetwornikami prędkości za pomocą modułów interfejsu Bently Nevada 86517 i 86497.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten monitor może śledzić częstotliwości drgań związane ze zmiennymi prędkościami maszyny?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, zintegrowany filtr śledzący używa stałego współczynnika Q i jest ważny dla prędkości maszyny od 60 do 240 000 cpm, co pozwala na śledzenie amplitud drgań 1X przy zmiennych warunkach pracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak system zapobiega wpływowi zwarcia na wyjściach rejestratora lub buforowanych na krytyczną ochronę maszyny?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMonitorowanie pracy pozostaje całkowicie niezakłócone przez zwarcia na wyjściach rejestratora lub buforowanych wyjściach koncentrycznych na panelu przednim, ponieważ kanały posiadają wbudowaną izolację i ochronę przed zwarciami.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest funkcja konfiguracji multimode w tym urządzeniu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMultimode pozwala kanałom posiadać do ośmiu zestawów oddzielnych parametrów alarmowych, w tym punktów ostrzegawczych i niebezpiecznych, które dynamicznie przełączają się, aby dopasować się do aktywnego trybu pracy turbiny gazowej za pomocą sprzętowych wejść stykowych lub poleceń oprogramowania bramy komunikacyjnej.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666851590507,"sku":"3500\/44-02-00 126623-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-44-02-00-126623-01-aero-gt-i-o-module-stdanlmz0rk_ffad6ba4-960f-44bf-a455-145f4b9fc998.jpg?v=1765449063"},{"product_id":"bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbus-i-o-module","title":"Moduł I\/O Ethernet\/RS232 Modbus Bently Nevada 3500\/92-03-01-00 136188-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/92-03-01-00\u003c\/strong\u003e to \u003cstrong\u003emoduł bramy komunikacyjnej\u003c\/strong\u003e zaprojektowany dla \u003cstrong\u003esystemu ochrony maszyn serii 3500\u003c\/strong\u003e. Jego głównym celem jest zapewnienie ciągłej, szybkiej komunikacji dla wszystkich wartości i statusów monitorowanych w szafie, umożliwiając płynną integrację z rozproszonymi systemami sterowania (DCS), programowalnymi sterownikami logicznymi (PLC), interfejsami człowiek-maszyna (HMI) oraz innymi systemami automatyzacji zakładu.\u003c\/p\u003e\n\u003cp\u003eModuł posiada kompleksowe interfejsy komunikacyjne, wykorzystujące zarówno Ethernet TCP\/IP, jak i kanały szeregowe (RS232) za pośrednictwem \u003cstrong\u003emodułu I\/O 136188-01\u003c\/strong\u003e. Obsługuje wewnętrzne zbieranie danych, pobierając aktualne wartości pomiarowe, oznaczenia czasowe, statusy modułów oraz statusy alarmów z innych modułów monitorujących w szafie przez wysokowydajną sieć wewnętrzną. Dodatkowo, \u003cstrong\u003e3500\/92\u003c\/strong\u003e obsługuje bezpośrednią komunikację Ethernet z autorskim \u003cstrong\u003eoprogramowaniem konfiguracyjnym 3500 Rack\u003c\/strong\u003e oraz \u003cstrong\u003eoprogramowaniem do akwizycji danych\u003c\/strong\u003e. Ta konkretna wersja posiada konfigurowalne narzędzie Modbus Register Utility do efektywnego mapowania danych systemowych w sieciach automatyki nadrzędnej.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCiągłe zbieranie danych z szafy, w tym aktualnych wartości pomiarowych z oznaczeniami czasowymi, statusów modułów i alarmów.\u003c\/li\u003e\n\u003cli\u003eMożliwość jednoczesnej komunikacji przez Ethernet TCP\/IP i łącza szeregowe.\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne narzędzie Modbus Register Utility do dostosowywania mapowania rejestrów dla systemów nadrzędnych.\u003c\/li\u003e\n\u003cli\u003eWysokowydajna wewnętrzna sieć z szybkością zbierania danych, która aktualizuje wszystkie moduły w szafie w mniej niż 1 sekundę.\u003c\/li\u003e\n\u003cli\u003eWskaźniki LED na panelu przednim do natychmiastowego monitorowania statusu pracy modułu (OK) i aktywności komunikacji (TX\/RX).\u003c\/li\u003e\n\u003cli\u003eWsteczna kompatybilność z funkcjami oprogramowania oryginalnego modułu 3500\/90.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegracja monitorowania drgań i stanu turbin parowych i gazowych.\u003c\/li\u003e\n\u003cli\u003eTransmisja danych ochrony sprężarek i pomp do systemu DCS zakładu.\u003c\/li\u003e\n\u003cli\u003eSieci monitorowania stanu maszyn przemysłowych i predykcyjnej konserwacji.\u003c\/li\u003e\n\u003cli\u003eSynchronizacja automatyzacji elektrowni i zakładów petrochemicznych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3500\/92: Brama komunikacyjna\u003c\/li\u003e\n\u003cli\u003e03: Moduł I\/O Ethernet\/RS232 Modbus\u003c\/li\u003e\n\u003cli\u003e01: Niska pamięć\u003c\/li\u003e\n\u003cli\u003e00: Brak opcji zatwierdzenia agencji\u003c\/li\u003e\n\u003cli\u003e136188-01: Moduł I\/O Ethernet\/RS232 Modbus zapasowy (zawiera zestaw aktualizacji oprogramowania układowego 126M4118-01)\u003c\/li\u003e\n\u003cli\u003e126M4118-01: Zestaw aktualizacji oprogramowania układowego\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eTypowe zużycie mocy 5,0 W z modułem I\/O Modbus RS232\/RS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eTypy danych\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eAktualne wartości mierzone z sygnaturą czasową, statusy modułów, aktualne statusy alarmów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eCzas aktualizacji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eMniej niż 1 sekunda dla wszystkich modułów w szafie 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eWyjście diody OK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eWskazuje, kiedy 3500\/92 działa prawidłowo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eWyjście diody TX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eWskazuje, kiedy 3500\/92 komunikuje się z innymi modułami w szafie 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eProtokół hosta BNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003ePołączenie Ethernet TCP\/IP z oprogramowaniem 3500 Configuration and Data Acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eProtokół Modbus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eNa podstawie podręcznika AEG Modicon PI-MBUS-300, tryb transmisji Remote Terminal Unit (RTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003ePrędkość łącza Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e10 Mbps, zgodne z IEEE 802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eProtokół Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eRamka Ethernet TCP\/IP i Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003ePołączenie Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eRJ-45 do okablowania Ethernet 10BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-30°C do +65°C (-22°F do +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eWymiary płyty głównej (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e241 mm x 24,4 mm x 242 mm (9,50 in x 0,96 in x 9,52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eWymiary modułu I\/O (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e241 mm x 24,4 mm x 99,1 mm (9,50 in x 0,96 in x 3,90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eWaga płyty głównej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e0,82 kg (1,8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e0,44 kg (0,96 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003e\u003cstrong\u003eCałkowita waga zespołu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e1,26 kg (2,76 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003ePin złącza\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eGniazdo RJ-45\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eInterfejs Ethernet TCP\/IP 10BASE-T i Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003ePort szeregowy (RS232)\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eInterfejs komunikacji szeregowej Modicon Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeryfikacja oprogramowania układowego:\u003c\/strong\u003e Upewnij się, że starsze moduły główne Communication Gateway zostały zaktualizowane za pomocą zestawu aktualizacji oprogramowania układowego 126M4118-01 przed instalacją nowego modułu I\/O 136188-01.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWkładanie do szafy:\u003c\/strong\u003e Włóż płytę główną do wyznaczonego gniazda komunikacyjnego w szafie 3500, zapewniając pełne osadzenie i solidne dokręcenie śrub obudowy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyrównanie modułu I\/O:\u003c\/strong\u003e Zainstaluj moduł I\/O 136188-01 bezpośrednio za modułem głównym od tyłu szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOgraniczenia okablowania:\u003c\/strong\u003e Używaj standardowego okablowania Ethernet 10BASE-T z złączami RJ-45 do konfiguracji sieci, ograniczając długość kabli zgodnie z normą IEEE 802.3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKontrola środowiskowa:\u003c\/strong\u003e Upewnij się, że warunki pracy nie przekraczają 65°C i że drogi wentylacyjne w obudowie 3500 pozostają niezatkane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest funkcja modułu 3500\/92?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDziała jako brama komunikacyjna, eksportując dane z szafy ochrony maszyn 3500 do zewnętrznych systemów automatyki, takich jak PLC i DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie interfejsy są dostępne w module I\/O 136188-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZapewnia złącze Ethernet RJ-45 oraz interfejs szeregowy RS232.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie protokoły mogą działać przez połączenie Ethernet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eObsługuje protokół Modbus\/TCP oraz własny protokół hosta Bently Nevada dla aplikacji programowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzym ten moduł różni się od starszego modułu 3500\/90?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsuwa stałe rejestry Modbus wartości podstawowej i zastępuje je elastycznym narzędziem Configurable Modbus Register Utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak długo trwa odświeżenie danych z szafy przez moduł?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSzybkość zbierania danych zależy od konfiguracji, ale gwarantuje się, że nie przekroczy 1 sekundy dla wszystkich modułów.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie jest typowe zużycie energii dla tej konkretnej konfiguracji I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSystem zazwyczaj zużywa 5,0 W, gdy jest wyposażony w moduł I\/O Modbus RS232.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy mogę połączyć moje oprogramowanie 3500 Configuration przez tę bramkę?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, umożliwia komunikację Ethernet z pakietami oprogramowania 3500 Rack Configuration i Data Acquisition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo powinienem sprawdzić, jeśli dioda TX\/RX jest zgaszona?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSprawdź, czy moduł jest prawidłowo osadzony oraz czy wewnętrzna magistrala komunikacyjna szafy jest aktywna i działa poprawnie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy aktualizacja oprogramowania układowego jest obowiązkowa przy wymianie interfejsu 136188-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStarsze moduły głównej bramki wymagają aktualizacji oprogramowania układowego za pomocą zestawu 126M4118-01, aby prawidłowo rozpoznać nowy sprzęt I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie są ograniczenia dotyczące przechowywania tego sprzętu w środowisku?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł musi być przechowywany w zakresie temperatur otoczenia od -40°C do +85°C.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852540779,"sku":"3500\/92-03-01-00 136188-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbusi-o-module-p13m3rotikn_8ccc5100-a46c-4dba-8a08-f4cf661d45b3.jpg?v=1765449087"},{"product_id":"bently-nevada-3500-77m-04-00-143737-01-recip-cylinder-pressure-monitor","title":"Bently Nevada 3500\/77M-04-00 143737-01 Recip Cylinder Pressure Monitor","description":"\u003cp\u003eThe \u003cstrong\u003e3500\/77M\u003c\/strong\u003e, full part number \u003cstrong\u003e3500\/77M-04-00\u003c\/strong\u003e (incorporating main monitor module \u003cstrong\u003e3500\/77M\u003c\/strong\u003e and rear I\/O component \u003cstrong\u003e143737-01\u003c\/strong\u003e), is a 4-channel hardware module engineered within the 3500 Machinery Protection System to condition absolute pressure signals from approved positive voltage third-party transducers installed on reciprocating compressors. The instrument operates via continuous backplane communication to execute machinery protection logic by comparing eight discrete measured variables per channel—specifically Discharge Pressure, Suction Pressure, Maximum Pressure, Minimum Pressure, Compression Ratio, Peak Rod Compression, Peak Rod Tension, and Degree of Rod Reversal—against user-configurable alert and danger setpoints. This option -04-00 variant is structurally defined by a cylinder pressure I\/O module with external termination interfaces and no hazardous area agency approvals required. The module delivers internal current-limiting transducer power supplies at +23.0 Vdc per channel and outputs inverted, offset buffered analog signals through front-panel coaxial ports for diagnostic cross-analysis without impacting primary monitoring operations.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/77M-04-00: Complete Cylinder Pressure Monitor Assembly\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifies the combined kit consisting of the front main monitor module and the rear I\/O module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04: I\/O Module Type Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCylinder Pressure I\/O Module with External Terminations (Rear I\/O Module Part Number: \u003cstrong\u003e143737-01\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Agency Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo hazardous area agency approvals or certifications required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpares \u0026amp; Accessories\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number \u003cstrong\u003e143737-01\u003c\/strong\u003e: Cylinder Pressure I\/O Module with External Terminations for Bently Approved Third-Party Pressure Transducers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/77M-04-00 (I\/O Board: 143737-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Configurable pressure channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+0.5 Vdc to +10.0 Vdc (assuming +0.5 Vdc at 0 psia)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5.5 kHz on all configured channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Accuracy at +25 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ± 0.5% of pressure transducer full-scale (9.5 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Accuracy (-30 °C to +65 °C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ± 1.0% of pressure transducer full-scale (9.5 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8 W maximum at full transducer load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Transducer Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel coaxial ports, inverted and offset by -2.265 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+23.0 ± 0.8 Vdc with 24.5 mA current limiting per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 °C to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombined Total Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.11 kg (Combined monitor front card and rear I\/O module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe cylinder pressure I\/O module processing logic dynamically alters its signal conversion scale factor based on the programmed target range, scaling from 95,000 mV\/psi for 100 psia down to 950 mV\/psi for 10,000 psia systems.\u003c\/li\u003e\n\u003cli\u003eFor single-chamber rod dynamics diagnostics, Peak Rod Compression, Peak Rod Tension, and Degree of Rod Reversal calculations mathematically integrate physical raw casing measurements with internal multi-channel variables.\u003c\/li\u003e\n\u003cli\u003eFront panel buffered coaxial outputs are short-circuit protected but are structurally inverted and offset by -2.265 Vdc when interacting with the external termination I\/O module architecture.\u003c\/li\u003e\n\u003cli\u003eControl logic allows the mapping of independent alert setpoints across all active measured variables, whereas danger setpoints are strictly limited to a maximum of two variables per channel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the external termination block to the rear I\/O chassis interface via shielded, twisted-pair wiring assemblies to preserve high-frequency signal integrity and prevent noise injection.\u003c\/li\u003e\n\u003cli\u003eTerminate the field transducer cable shields exclusively at the designated external termination block ground strip to avoid creating parallel ground loops with the machine casing ground.\u003c\/li\u003e\n\u003cli\u003eObserve the strict 24.5 mA current-limiting parameters on the +23.0 Vdc internal supply lines when interfacing with third-party absolute pressure sensors.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum bend radius limits for all external field cabling routing into the 3500 chassis enclosure to eliminate mechanical tension on the termination terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why do the front-panel buffered outputs on the 3500\/77M-04-00 show negative voltage offsets on an oscilloscope?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This behavior is normal for this specific architecture; the cylinder pressure external termination I\/O electronics are structurally designed to invert and offset the raw signal by -2.265 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this pressure monitor module be swapped or inserted into any random slot within a 3500 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the module must be positioned into a standard chassis slot compatible with monitoring modules and must line up directly with its corresponding 143737-01 rear external termination I\/O board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum distance or line resistance supported for the third-party pressure transducer connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Cable distance limits depend on the specific capacitance of the field cable, but signal integrity over long distances is maintained due to the high 50 kΩ input impedance of the I\/O block.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666853622123,"sku":"3500\/77M-04-00 143737-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-77m-04-00-143737-01-cylinder-pressure-i-o-with-external-terminations-cucl2dsyu4l_d9795dee-d7e1-432c-9d3d-db6e36a719d6.jpg?v=1765449115"}],"url":"https:\/\/www.plcprotech.com\/pl\/collections\/bently-nevada-3500-system-machinery-protection.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}