{"title":"I\/O Modules","description":"\u003cp\u003eI\/O Modules bridge the gap between physical field devices and the digital control environment of a PLC or DCS. The system architecture consists of isolated input channels for sensors and output channels for actuators, often housed in ruggedized, hot-swappable enclosures. Technical characteristics include optical isolation for circuit protection, varying voltage ranges (AC\/DC), and high-density channel configurations. Functionally, these modules convert analog or discrete electrical signals into data packets for the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/cpus\"\u003eCPU\u003c\/a\u003e to process. By utilizing modular \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/iota-bases\"\u003eIOTA and bases\u003c\/a\u003e, they enable flexible system expansion and simplified field wiring, ensuring precise monitoring and control of industrial machinery and process loops.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-289837-01-3500-encore-proximitor-seismic-i-o-module","title":"Moduł Wejścia\/Wyjścia Proximitor\/Sejsmiczny Bently Nevada 289837-01 3500 ENCORE","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e to wysokowydajny moduł wejścia\/wyjścia Proximitor\/Seismic zaprojektowany specjalnie dla systemu ochrony maszyn Bently Nevada 3500 ENCORE. Moduł ten pełni kluczową rolę jako interfejs tylnej płyty dla monitora drgań 3500\/42E, umożliwiając podłączenie do czterech kanałów czujników zbliżeniowych lub sejsmicznych. Szeroko stosowany w sektorach energetycznym, naftowym, gazowym i górniczym, \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e pozwala na monitorowanie istotnych parametrów maszyn, takich jak drgania promieniowe, pozycja osiowa i ekscentryczność. Zapewniając niezawodne kondycjonowanie sygnału i przesył do głównego procesora, moduł ten gwarantuje ciągłą ochronę maszyn oraz wysoką jakość pozyskiwanych danych. Jest niezbędnym elementem dla zakładów przechodzących z systemów 3300 na platformę ENCORE, umożliwiając nowoczesny monitoring drgań bez utraty integralności okablowania polowego.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003eModuł wejścia\/wyjścia \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e został zaprojektowany tak, aby wspierać dwuarchekturalne możliwości serii 3500 ENCORE, zapewniając maksymalną elastyczność w monitorowaniu drgań i pozycji.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eObsługa czterech kanałów:\u003c\/strong\u003e W standardowej szafie systemu 3500 ENCORE moduł obsługuje cztery niezależne kanały, programowane parami (kanały 1 i 2; kanały 3 i 4) do realizacji określonych funkcji monitorowania.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWszechstronność czujników:\u003c\/strong\u003e Kompatybilny z szerokim zakresem czujników, w tym sondami zbliżeniowymi do pomiarów łożysk ślizgowych oraz czujnikami sejsmicznymi (akcelerometry lub czujniki prędkości) do pomiaru drgań obudowy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegracja systemowa:\u003c\/strong\u003e W konfiguracji systemu 3500 ENCORE moduł I\/O współpracuje z programowalnymi modułami przekaźnikowymi, które sterują obwodami awaryjnego wyłączenia maszyn na podstawie zdefiniowanych przez użytkownika progów Alarmu i Niebezpieczeństwa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogika kondycjonowania:\u003c\/strong\u003e Każdy kanał przetwarza surowe sygnały z czujników na „wartości statyczne”, dostarczając personelowi operacyjnemu diagnostykę stanu maszyn w czasie rzeczywistym zarówno w warunkach ustalonych, jak i przejściowych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e289837-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 ENCORE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuł wejścia\/wyjścia Proximitor\/Seismic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eObsługa kanałów\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kanały (tryb systemowy) \/ 2 kanały (aktualizacja szafy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 do +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 do +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% bez kondensacji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,68 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208,28 mm x 48,26 mm x 127 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania dotyczące zastosowań przemysłowych\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCzy moduł 289837-01 może być używany jako bezpośredni zamiennik modułów I\/O serii 3300?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie. Chociaż system 3500 ENCORE jest zaprojektowany do modernizacji monitorów 3300, \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e jest przeznaczony wyłącznie do użytku w szafie systemu 3500 ENCORE. W konfiguracjach „aktualizacji szafy”, gdzie pozostaje obudowa 3300, system korzysta z istniejących modułów I\/O serii 3300.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł I\/O obsługuje jednocześnie drgania promieniowe i pozycję osiową?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak. Ponieważ kanały są programowane parami, można skonfigurować kanały 1 i 2 do monitorowania drgań promieniowych, a kanały 3 i 4 do położenia osiowego (lub innej obsługiwanej funkcji) w tym samym monitorze 3500\/42E.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak moduł radzi sobie z błędami sygnału, takimi jak odłączony czujnik?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMonitor 3500\/42E, współpracujący z \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e, wykonuje ciągłe autodiagnostyki. W przypadku awarii sygnału czujnika lub uszkodzenia okablowania monitor zgłasza status „Nie OK”, zapobiegając fałszywym wyłączeniom i powiadamiając dział utrzymania ruchu za pomocą oprogramowania 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik inżynierii terenowej i instalacji\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOkablowanie i ekranowanie:\u003c\/strong\u003e Podczas podłączania czujników Proximitor lub Seismic do zacisków \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e należy upewnić się, że ekrany kabli są uziemione wyłącznie przy module I\/O. Nie należy uziemiać ekranów po stronie czujnika, aby uniknąć pętli masy, które mogą wprowadzać zakłócenia i obniżać dokładność pomiaru drgań.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontaż i dokręcanie:\u003c\/strong\u003e Upewnij się, że moduł I\/O jest całkowicie osadzony z tyłu szafy ENCORE, a śruby mocujące są odpowiednio dokręcone, aby zabezpieczyć moduł przed tylną płytą. Jest to kluczowe dla zachowania integralności sygnału w środowiskach o wysokich drganiach, typowych dla stanowisk sprężarek lub hal turbin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOchrona środowiskowa:\u003c\/strong\u003e Chociaż moduł jest przystosowany do pracy przy wilgotności do 95% bez kondensacji, powinien być zawsze instalowany w obudowie o klasie NEMA 4 lub IP65, jeśli znajduje się w miejscach o wysokiej wilgotności lub obecności substancji korozyjnych. Zapewnij odpowiednią cyrkulację powietrza w szafie, aby utrzymać temperaturę pracy poniżej 65 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeryfikacja konfiguracji:\u003c\/strong\u003e Po wymianie modułu I\/O zawsze używaj oprogramowania 3500 Rack Configuration Software, aby potwierdzić, że parowanie kanałów i typy czujników odpowiadają zainstalowanym w terenie. Wykonaj test pętli, aby upewnić się, że progi Alarmu i Niebezpieczeństwa prawidłowo sterują powiązanymi modułami przekaźnikowymi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516898155,"sku":"3500\/42E 289837-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42e-289837-01-vibration-monitor-5lwybpzw3c4_d9f2ca71-9841-4ea7-b237-17c1fd8f0f71.jpg?v=1765440098"},{"product_id":"bently-nevada-133819-02-3500-61-rtd-tc-non-isolated-i-o-module","title":"Moduł Wejścia\/Wyjścia Nieizolowany Bently Nevada 133819-02 3500\/61 RTD\/TC","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBently Nevada \u003cstrong\u003e133819-02\u003c\/strong\u003e\u003c\/span\u003e to specjalistyczny \u003cspan\u003emoduł RTD\/TC bez izolacji I\/O\u003c\/span\u003e zaprojektowany dla \u003cstrong\u003emonitoru temperatury 3500\/61.\u003c\/strong\u003e Moduł ten zapewnia fizyczny interfejs dla sześciu kanałów monitorowania temperatury, obsługując zarówno detektory temperatury rezystancyjnej (RTD), jak i termopary (TC). \u003cspan\u003e133819-02\u003c\/span\u003e posiada \u003cspan\u003ewewnętrzne zaciski\u003c\/span\u003e, umożliwiające podłączenie okablowania bezpośrednio do bloków zaciskowych na samym module I\/O. Ta wersja bez izolacji oferuje maksymalną elastyczność, pozwalając użytkownikom na konfigurację modułu dla TC, RTD lub mieszanki obu typów czujników na sześciu kanałach.\u003c\/p\u003e\n\u003ch3\u003eFunkcjonalna inteligencja i wyjścia rejestratora\u003c\/h3\u003e\n\u003cp\u003eJako komponent serii \u003cspan\u003e3500\/61\u003c\/span\u003e, ten moduł I\/O zawiera dedykowane \u003cspan\u003ewyjścia rejestratora\u003c\/span\u003e dla każdego z sześciu kanałów. Dostarcza sygnał \u003cspan\u003e+4 do +20 mA\u003c\/span\u003e proporcjonalny do pełnej skali monitora, umożliwiając płynną integrację z zewnętrznymi systemami sterowania, DCS lub rejestratorami wykresowymi do zapisu danych. Architektura modułu jest odporna na awarie; działanie monitora nie jest zakłócane przez zwarcia na wyjściach rejestratora, co zapewnia ciągłość podstawowych funkcji ochrony maszyn.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eAtrybut\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSzczegóły specyfikacji\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumer części\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e133819-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKompatybilność monitora\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/61\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKanały wejściowe\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 (programowalne indywidualnie dla RTD lub TC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTyp zakończenia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWewnętrzne zaciski (na module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIzolacja\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBez izolacji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eŹródło prądu RTD\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 15 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA @ 25 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWyjście rejestratora\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+4 do +20 mA (obciążenie: 0 do 600 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΩ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDokładność (wewnętrzna)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 3 °C @ 25 °C (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 5,4 °F @ 77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperatura pracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C do +65 °C (-22 °F do +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWaga\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,45 kg (1,0 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWymiary (WxSxG)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 99,1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eJaka jest główna różnica między modułami 3500\/60 a 3500\/61?\u003c\/span\u003eOba moduły oferują identyczną funkcjonalność monitorowania temperatury na sześciu kanałach. Jednak \u003cspan\u003e3500\/61\u003c\/span\u003e (używający modułu I\/O \u003cspan\u003e133819-02\u003c\/span\u003e) posiada wyjścia rejestratora 4-20 mA dla każdego kanału, podczas gdy 3500\/60 nie oferuje tych wyjść analogowych.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCzy mogę mieszać różne typy czujników na jednym module 133819-02?\u003c\/span\u003eTak. W przeciwieństwie do wersji izolowanych, ten moduł I\/O bez izolacji może być skonfigurowany za pomocą \u003cspan\u003eoprogramowania konfiguracyjnego 3500 Rack\u003c\/span\u003e, aby akceptować dowolną kombinację wejść TC i RTD na sześciu kanałach.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJak moduł obsługuje okablowanie RTD?\u003c\/span\u003eModuł dostarcza specjalistyczne źródło prądu o wartości \u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA\u003c\/span\u003e. Jest zaprojektowany do obsługi RTD 3-przewodowych (używając dwóch źródeł prądu do kompensacji przewodów) oraz RTD 4-przewodowych (używając pojedynczego źródła), co zapewnia dokładny pomiar temperatury dla różnych typów przetworników.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik inżynieryjny i instalacyjny\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eZarządzanie wewnętrznymi zaciskami:\u003c\/span\u003e \u003cspan\u003e133819-02\u003c\/span\u003e wykorzystuje wewnętrzne bloki zaciskowe. Upewnij się, że okablowanie polowe jest odpowiednio oznakowane i solidnie przymocowane, aby zapobiec przerywanym sygnałom, które mogłyby wywołać diody LED statusu „Bypass” lub „Error” na przednim panelu monitora.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarunki środowiskowe:\u003c\/span\u003e Moduł jest przystosowany do pracy w zakresie temperatur od \u003cspan\u003e-30 °C do +65 °C\u003c\/span\u003e. W przypadku instalacji w ekstremalnych warunkach zapewnij odpowiednią wentylację szafy 3500, aby utrzymać te limity i zapobiec dryfowi dokładności.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKonfiguracja TMR:\u003c\/span\u003e W zastosowaniach z potrójną modularną redundancją (TMR) należy zainstalować trzy monitory temperatury w sąsiednich grupach. System stosuje dwa typy głosowania, aby zapobiec fałszywym alarmom spowodowanym pojedynczymi awariami w krytycznych maszynach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZalety inżynieryjne\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBently Nevada 133819-02\u003c\/span\u003e oferuje ekonomiczne, wysokogęstościowe rozwiązanie do ochrony temperatury maszyn. Łącząc obsługę TC i RTD w jednym module z wewnętrznymi zaciskami, zmniejsza zajmowaną przestrzeń w szafie i upraszcza okablowanie. Przy zakupach B2B wybór oryginalnego \u003cspan\u003e133819-02\u003c\/span\u003e gwarantuje pełną kompatybilność z \u003cspan\u003esystemem monitoringu 3500\u003c\/span\u003e, zachowując wysoką dokładność i wytrzymałość niezbędną do ochrony turbin, sprężarek i dużych silników przemysłowych.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518864235,"sku":"133819-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133819-02-rtd-tc-temp-i-o-module-olhm4jqsb0w_ea2a25c8-3e12-4f5e-a5c2-4a168d80f750.jpg?v=1765440121"},{"product_id":"bently-nevada-133442-01-3500-50m-i-o-module-with-internal-terminations","title":"Bently Nevada 133442-01 3500\/50M I\/O Module with Internal Terminations","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel Tachometer Input\/Output (I\/O) module designed for the 3500 Series Machinery Protection System. This module serves as the primary physical interface for field wiring, specifically engineered to operate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTachometer Main Modules. It processes high-frequency pulse inputs from proximity probes or passive magnetic pickups to facilitate precise measurements of rotational speed, rotor acceleration, and reverse rotation.\u003c\/p\u003e\n\u003cp\u003eAs an internal termination variant, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures integrated screw terminal blocks directly on the module body, optimizing it for high-density cabinet installations where space is a priority. This hardware configuration is widely deployed in power generation, petrochemical, and gas compression facilities for continuous machinery monitoring and critical overspeed protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTachometer I\/O Module with Internal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-channel differential or single-ended pulse inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity probe systems, Magnetic pickups\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+10.0 Vdc to -24.0 Vdc (internally limited)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.15 kΩ (Internal Barrier variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 163.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg (1.01 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 deg C to +65 deg C (-22 deg F to +149 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eWhen procuring spare parts, ensure the part number matches the specific rack configuration to avoid hardware\/software mismatch errors.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComponent Description\u003c\/strong\u003e: 3500\/50M Tachometer I\/O Module with Internal Terminations (Internal Barrier Type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated Main Module\u003c\/strong\u003e: 3500\/50-01-XX or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M-01-XX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Fixed screw terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003ch3\u003eWiring and Shielding Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection\u003c\/strong\u003e: Use twisted, shielded pair cabling (18 AWG to 22 AWG) for all transducer connections to mitigate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Connect shields to the designated instrument ground terminal on the 3500 rack chassis at one end only. Do not ground at the field transducer to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Separation\u003c\/strong\u003e: Maintain a minimum distance of 300 mm (12 inches) between speed sensor cables and high-voltage AC power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Hot-Swap Precautions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Alignment\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be installed in the rear slot corresponding to the front-mounted 3500\/50M main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBypass Protocol\u003c\/strong\u003e: Prior to module extraction or insertion, bypass all associated machinery trip relays to prevent accidental turbine or compressor trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Limits\u003c\/strong\u003e: Tighten terminal block screws to a maximum of 0.56 N·m (5 in·lb) to protect the internal PCB traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 133442-01 compatible with older 3500\/50 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is fully backwards compatible with standard 3500\/50 and upgraded 3500\/50M modules, provided the rack configuration software matches the hardware variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and the External Termination (ET) version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures built-in terminal blocks. The ET version requires a multi-pin cable to connect to a remote DIN-rail terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the risks of exceeding the input signal range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile internal clipping circuits limit voltages, sustained overvoltage outside the +10V to -24V range can degrade the internal barrier circuitry and cause channel faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519650667,"sku":"133442-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133442-01-i-o-module-with-internal-terminations-1a4iq1cd4r4_bc83d92f-d0df-4c88-95ae-2fed0e219041.jpg?v=1765440137"},{"product_id":"bently-nevada-136711-02-3500-61-rtd-tc-i-o-module","title":"Bently Nevada 136711-02 3500\/61 RTD\/TC I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136711-02\u003c\/strong\u003e is a specialized \u003cstrong\u003eRTD\/TC I\/O Module with Internal Barriers and Internal Terminations\u003c\/strong\u003e developed for the \u003cstrong\u003e3500\/61 16-Channel Temperature Monitor\u003c\/strong\u003e within the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This hardware component serves as the physical interface layer that collects multi-channel temperature signals from field-located transducers. This specific non-isolated variant is engineered with integrated safety barriers, allowing users to configure the termination paths to accept either thermocouple (TC) or resistance temperature detector (RTD) inputs, as well as a flexible combination of both sensor categories simultaneously within the same rack subsystem.\u003c\/p\u003e\n\u003cp\u003eField programming and configuration of channel types are handled through the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e, removing any requirements for physical hardware modifications or field calibration procedures. The module conditions the raw millivolt signals from thermocouples and resistance variances from 3-wire or 4-wire RTDs, feeding structured digital temperature values directly into the main front processor card via the internal backplane bus. Its onboard intrinsic safety design provides a high degree of integration by combining terminal blocks and hazardous area containment barriers into a single space-saving footprint, making the \u003cstrong\u003e3500\/61\u003c\/strong\u003e subsystem ideal for multi-point thermal surveillance of bearings, stator windings, and exhaust paths on heavy rotating assets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHouses physical internal termination blocks paired with integrated safety barriers for hazardous field environments.\u003c\/li\u003e\n\u003cli\u003eNon-isolated universal channel paths support individual configuration for TCs, 3-wire RTDs, or 4-wire RTDs.\u003c\/li\u003e\n\u003cli\u003eEliminates the need for manual component calibration through full integration with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes dedicated high-precision current source networks to satisfy multi-lead RTD measuring circuits.\u003c\/li\u003e\n\u003cli\u003eStructural design optimizes rack footprint by consolidating external terminal boxes and separate intrinsic safety hardware into one rear slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-channel motor and generator stator winding thermal monitoring.\u003c\/li\u003e\n\u003cli\u003eGas turbine exhaust gas temperature (EGT) profile tracking and distribution mapping.\u003c\/li\u003e\n\u003cli\u003eIndustrial bearing temperature monitoring on high-speed pumps, fans, and gearboxes.\u003c\/li\u003e\n\u003cli\u003eBalance-of-plant auxiliary machinery protection across chemical and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e136711-02: RTD\/TC I\/O Module with Internal Barriers and Internal Terminations (Non-Isolated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical \u0026amp; Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Subtype\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated with Internal Safety Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Current Source Value\u003c\/td\u003e\n\u003ctd\u003e925 +\/- 15 uA at 25 degC per transducer (1 supply for 4-wire RTD, 2 supplies for 3-wire RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer \u0026amp; Sensor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple (TC) Capability\u003c\/td\u003e\n\u003ctd\u003eType E, Type J, Type K, Type T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Temperature Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eType E: -100 degC to +1000 degC (-148 degF to +1832 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType J: -18 degC to +760 degC (+0 degF to +1400 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType K: -18 degC to +1370 degC (+0 degF to +2498 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType T: -160 degC to +400 degC (-256 degF to +752 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Temperature Detector (RTD)\u003c\/td\u003e\n\u003ctd\u003e100 Ohm platinum (alpha = 0.00385), 100 Ohm platinum (alpha = 0.00392), 120 Ohm nickel, 10 Ohm copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Measurement Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -200 degC to +850 degC (-328 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -200 degC to +700 degC (-328 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -80 degC to +260 degC (-112 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -100 degC to +260 degC (-148 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges with External Barriers\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -50 degC to +850 degC (-122 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -50 degC to +260 degC (-122 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Conditioning \u0026amp; Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF (except for 10 Ohm Copper RTDs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Isolated External Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-1 degC at 25 degC (+\/-1.8 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolated Internal Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-2 degC at 25 degC (+\/-3.6 degF at 77 degF) \/ +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eNo field calibration required; specified at +25 degC (+77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Dimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Position Requirements\u003c\/td\u003e\n\u003ctd\u003eConsumes 1 full-height rear slot directly behind the main monitor processor card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Barrier Screw Terminals\u003c\/td\u003e\n\u003ctd\u003eDirect physical land connection for raw multi-wire RTD leads and TC field extensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Backplane Bus Plug\u003c\/td\u003e\n\u003ctd\u003eMulti-pin interconnect matrix delivering conditioned sensor data to the 3500 rack bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Install the \u003cstrong\u003e136711-02\u003c\/strong\u003e module directly from the rear side of the 3500 monitoring chassis. It must align perfectly into the slot corresponding to the front-mounted 3500\/61 main processor card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type Matching:\u003c\/strong\u003e Verify through configuration utility software that each channel configuration (thermocouple versus 3-wire or 4-wire RTD) exactly matches the field wire layout connected to the terminal strip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Wire Uniformity:\u003c\/strong\u003e For all 3-wire and 4-wire RTD configurations, employ copper lead wires of uniform gauge and length to guarantee precise lead-resistance compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Control:\u003c\/strong\u003e Run all external field sensor lines through twisted, shielded wire pairs. Land the shields at the designated instrumentation ground terminal provided on the module frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enforcement:\u003c\/strong\u003e Ensure the cabinet installation maintains clean, unobstructed ventilation paths so that the active operating ambient temperature around the internal barrier housing does not exceed 65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 136711-02 component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as the rear terminal and intrinsic safety interface module that routes field RTD and thermocouple signals into a 3500\/61 monitor slot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the designation non-isolated mean for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt indicates that the channels share a common ground reference point, although they remain protected via built-in internal safety barriers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix thermocouples and RTDs on the same I\/O card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the non-isolated channel paths can be customized individually via software to accept a mixed combination of TCs and RTDs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific type of RTD is recommended for standard engineering installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlatinum RTDs featuring an alpha value of 0.00385 are the industrial standard and are highly recommended for optimal precision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs manual field calibration required after replacing this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo manual field calibration is needed because all channel parameter scaling is managed automatically through system configuration software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat constant current value is provided for RTD sensors by this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated current source network delivers 925 +\/- 15 uA at an environmental reference of 25 degC per transducer pathway.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many internal current supplies are engaged when a 4-wire RTD is connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module configuration activates a single current supply line for a 4-wire RTD circuit and two separate supplies for a 3-wire RTD circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the defined operating temperature limitation for this module version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is specified to perform reliably in a continuous ambient temperature environment ranging from 0 degC to +65 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the exact physical dimensions of this rear-mount component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe card measures 241.3 mm in height, 24.4 mm in width, and 163.1 mm in depth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this component contain the primary digital processor card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this part number represents the rear-insert I\/O termination assembly with built-in barriers; the front processor module is supplied separately.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520273259,"sku":"3500\/61 136711-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-136711-02-temperature-module-cnm5uk4ps0a_ea8ec829-abb6-47bf-af49-d0ad661bbb09.jpg?v=1765440149"},{"product_id":"bently-nevada-135473-01-3500-25-keyphasor-i-o-module-internal-barriers","title":"Moduł wejścia\/wyjścia Bently Nevada 135473-01 3500\/25 Keyphasor (wewnętrzne bariery)","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eBently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto specjalistyczny moduł I\/O o połowie wysokości zaprojektowany dla systemu\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced Keyphasor. Ta konkretna konfiguracja integruje\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBariery Wewnętrzne\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoraz\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eZakończenia Wewnętrzne\u003c\/strong\u003e, zapewniając sprzętowy interfejs bezpieczeństwa wewnętrznego dla przetworników umieszczonych w strefach zagrożonych. Moduł jest zaprojektowany do odbioru i przetwarzania sygnałów impulsowych raz na obrót lub wielokrotnie na obrót z sond zbliżeniowych lub czujników magnetycznych, które są niezbędne do obliczania prędkości obrotowej maszyny oraz dostarczania odniesienia fazowego do analizy drgań.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epełni funkcję fizycznego interfejsu w szafie 3500, zapewniając izolację elektryczną i kondycjonowanie sygnału dla krytycznej ochrony maszyn. Chociaż moduł obsługuje pomiary fazy, jest zoptymalizowany do monitorowania prędkości wału z wysoką dokładnością. Korzystając z wersji z barierą wewnętrzną, moduł zapewnia bezpieczny punkt połączenia, który ogranicza energię elektryczną wysyłaną do czujników polowych, spełniając rygorystyczne przemysłowe normy bezpieczeństwa dla atmosfer wybuchowych.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuł I\/O Keyphasor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeria 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp zakończenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZakończenia wewnętrzne\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfejs bezpieczeństwa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBariery wewnętrzne (typ Zenera)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKanały wejściowe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 sygnały przetworników (proximity lub czujnik magnetyczny)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypowo 3,2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum 21,8 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZakres sygnału (bez izolacji)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+0,8 V do -21,0 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimalna prędkość czujnika magnetycznego\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003e 200 obr.\/min (3,3 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 103,1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,46 kg (1,01 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C do +65°C (32°F do +150°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% bez kondensacji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cp\u003eZakupy przemysłowe powinny koncentrować się na konkretnym numerze części, aby zapewnić kompatybilność z konfiguracją monitora 3500\/25.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e: Moduł I\/O Keyphasor z barierami wewnętrznymi i zakończeniami wewnętrznymi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStan\u003c\/strong\u003e: Nowy oryginalny\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDostępność\u003c\/strong\u003e: Magazyn części zamiennych\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł może zapewnić izolację dla aplikacji Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, jest kompatybilny z aplikacjami Proximitor, ale wymaga zewnętrznego zasilania do zapewnienia izolacji.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest główny cel projektowy wersji z izolowanym I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZostał stworzony specjalnie do zastosowań z czujnikami magnetycznymi, gdzie sygnały są podłączone równolegle do wielu urządzeń, takich jak systemy sterowania.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCo się dzieje, gdy sygnały wejściowe przekraczają określony zakres?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSygnały przekraczające określony zakres napięcia są wewnętrznie ograniczane przez obwody modułu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOdwołanie techniczne: Okablowanie, zwory i specyfikacje\u003c\/h3\u003e\n\u003ch3\u003e1. OKABLOWANIE KANAŁU I DEFINICJE PINÓW\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ejest wewnętrznym modułem zakończenia I\/O z wbudowanymi barierami galwanicznymi. Posiada dwa niezależne listwy zaciskowe dla Kanału 1 i Kanału 2.\u003c\/p\u003e\n\u003ch4\u003eA. Okablowanie czujnika zbliżeniowego (3-przewodowe)\u003c\/h4\u003e\n\u003cp\u003eDla standardowych czujników prądów wirowych (np. seria 3300 XL):\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR (-24V):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWyjście zasilania dla Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM (GND):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWspólny\/zwrotny sygnał.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG (OUT):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWejście sygnału napięciowego impulsu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Okablowanie czujnika magnetycznego (pasywne 2-przewodowe)\u003c\/h4\u003e\n\u003cp\u003eDla samogenerujących elektromagnetycznych czujników prędkości:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz do dodatniego (+) przewodu czujnika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz do ujemnego (-) przewodu czujnika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMuszą pozostać odłączone (pływające).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Ekranowanie i uziemienie IS\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSHLD (Ekran):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz ekrany kabli polowych do tego dedykowanego zacisku.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUziemienie IS :\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModuł ten musi być uziemiony przez\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01 Moduł uziemienia bariery\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edo dedykowanej szyny uziemienia bezpieczeństwa iskrobezpiecznego, aby zapewnić integralność przeciwwybuchową.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. KONFIGURACJE ZWOREK SPRZĘTOWYCH\u003c\/h3\u003e\n\u003cp\u003eZworki znajdują się na wewnętrznej płytce drukowanej i muszą być ustawione przed instalacją.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eZworka zasilania przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eZworka sprzęgająca wejście\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunkcja logiczna\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCzujnik zbliżeniowy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eINT\u003c\/strong\u003e (Wewnętrzny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC\u003c\/strong\u003e (Prąd stały)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDostarcza zasilanie; umożliwia polaryzację DC.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCzujnik magnetyczny\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEXT\u003c\/strong\u003e (Zewnętrzny\/WYŁĄCZONY)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC\u003c\/strong\u003e (Prąd zmienny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOdłącza zasilanie; filtruje szumy DC.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eWAŻNE:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eZawsze wyłącz zasilanie szafy 3500 lub usuń moduł monitorujący przed regulacją zworek, aby uniknąć łuku elektrycznego.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr\u003e\n\u003ch3\u003e3. PODSTAWOWE SPECYFIKACJE WYDAJNOŚCI\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePojemność kanału:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 niezależne kanały wejściowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZakres częstotliwości:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 do 1 200 000 cpm (\u003cstrong\u003e0,017 Hz do 20 kHz\u003c\/strong\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZakres napięcia wejściowego:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+5V do -11V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(specjalnie dla Barier I\/O).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTryby kondycjonowania:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg automatyczny:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMinimalny sygnał 2 V szczyt-szczyt; minimalna prędkość 120 obr.\/min.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg ręczny:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegulowany od 0 do -20 V DC; minimalny sygnał 500 mV; obsługuje niskie prędkości do 1 obr.\/min.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eŚrodowiskowe:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eZużycie energii:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3,2 Waty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(typowe).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperatura pracy:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0°C do 65°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. CERTYFIKATY STREF ZAGROŻONYCH\u003c\/h3\u003e\n\u003cp\u003eZaprojketowany do środowisk wysokiego ryzyka:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmeryka Północna:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKlasa I, Div 2, Grupy A, B, C, D.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEuropa (ATEX):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eII 1 G [EEx ia] IIC (Wejścia ocenione na Strefę 0).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e5. WSPARCIE KONFIGURACJI SYSTEMU\u003c\/h3\u003e\n\u003cp\u003ePo fizycznej instalacji użyj\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoprogramowania do konfiguracji szafy 3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaby zweryfikować:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUstawienia histerezy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAby zapobiec fałszywym wyzwoleniom na zakłóconych sygnałach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrientacja:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUstawienie kierunku impulsu (dodatni\/ujemny).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAktywne kanały:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eZapewnienie zgodności ustawień zworki w oprogramowaniu z fizycznymi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCZĘŚĆ 2: SCHEMATY ZACISKÓW I KONFIGURACJA OPROGRAMOWANIA\u003c\/h3\u003e\n\u003ch3\u003e1. ROZKŁAD PINÓW BLOKU ZACISKÓW (A\/B\/C\/D)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eużywa określonej sekwencji 4 zacisków dla każdego kanału. Poniżej znajduje się mapa połączeń do podłączenia okablowania terenowego:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eZacisk\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEtykieta\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCzujnik zbliżeniowy (3-przewodowy)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCzujnik magnetyczny (2-przewodowy)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePWR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 V DC zasilanie (biały)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBRAK POŁĄCZENIA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWspólny\/masa (czarny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSygnał ujemny (-)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWejście sygnału (czerwony)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSygnał dodatni (+)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSHLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEkranowanie\/przewód odprowadzający\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEkranowanie\/przewód odprowadzający\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e2. KONFIGURACJA OPROGRAMOWANIA (KONFIGURACJA SZAFY 3500)\u003c\/h3\u003e\n\u003cp\u003ePo zainstalowaniu sprzętu musisz skonfigurować następujące elementy w oprogramowaniu:\u003c\/p\u003e\n\u003ch4\u003eA. Ustawienia progu\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg automatyczny\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSystem automatycznie oblicza punkt wyzwalania na poziomie 50% amplitudy sygnału.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNajlepsze dla\u003c\/strong\u003e: Standardowych prędkości pracy (\u0026gt;120 obr.\/min) z czystymi, stałymi impulsami.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg ręczny\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRęcznie ustawiasz stałe napięcie (np. -8,0 V DC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrongNajlepsze dla\u003c\/strong\u003e: Rozruchów niskich prędkości lub sygnałów z istotnymi „zakłóceniami” lub szumem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWskazówka dotycząca obliczeń\u003c\/strong\u003e: Ustaw próg na środek między szczytem impulsu a sygnałem bazowym.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Histereza (redukcja szumów)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDla\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eczujników magnetycznych\u003c\/strong\u003e powinieneś ustawić wartość histerezy (zwykle\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0,2V do 0,5V\u003c\/strong\u003e), aby zapobiec „podwójnemu wyzwalaniu” monitora, jeśli sygnał jest zakłócony podczas przekraczania progu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Aktywne zbocze (kierunek)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNegatywne zbocze\u003c\/strong\u003e: Wyzwala, gdy sygnał przechodzi z 0V do -24V (standard dla większości sond Bently).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePozytywne zbocze\u003c\/strong\u003e: Wyzwala, gdy sygnał przesuwa się w kierunku dodatnim.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. KRYTYCZNA LISTA KONTROLNA INSTALACJI\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUziemienie bariery\u003c\/strong\u003e: Upewnij się, że moduł\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ejest zainstalowany w szafie. Bez tego 135473-01 nie może prawidłowo uziemić wewnętrznych barier bezpieczeństwa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKontrola zworki\u003c\/strong\u003e: Podwójnie sprawdź, czy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezworki Kanału 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ei\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKanału 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epasują do odpowiednich czujników. Częstym błędem jest pozostawienie zworki PWR na\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprzy użyciu czujnika magnetycznego, co może powodować zakłócenia lub nagrzewanie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKodowanie\u003c\/strong\u003e: Używaj\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estopni C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoraz\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCelsjusza\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ew swojej dokumentacji technicznej, aby uniknąć problemów z uszkodzonymi znakami, które wcześniej występowały w Twoim CMS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847134059,"sku":"135473-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135473-01-motion-controller-module-with-316l-stainless-steel-case-material-ag55zssqu3e_fe8b3db7-fd2e-41ca-ad85-8851d4d47e88.jpg?v=1765448946"},{"product_id":"bently-nevada-81546-01-xdcr-i-o-and-record-terminals","title":"Bently Nevada 81546-01 XDCR terminale wejścia\/wyjścia i rejestracji","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e81546-01\u003c\/strong\u003e to wysokiej niezawodności, przemysłowy \u003cstrong\u003emoduł wejścia\/wyjścia przetwornika i zacisków rejestrujących\u003c\/strong\u003e zaprojektowany do bezproblemowej integracji w systemach monitorowania stanu maszyn obrotowych. Ten specjalistyczny komponent zakończenia sprzętowego ustanawia krytyczne połączenia ścieżek sygnałowych między przetwornikami polowymi montowanymi na obudowie a scentralizowanymi monitorami ochrony majątku lub zewnętrznym sprzętem do rejestracji danych. \u003cstrong\u003e81546-01\u003c\/strong\u003e zapewnia strukturalne prowadzenie bloków zaciskowych dla surowych sygnałów sond zbliżeniowych, czujników prędkości lub akcelerometrów, jednocześnie dostarczając niezależne ścieżki do zacisków rejestrujących.\u003c\/p\u003e\n\u003cp\u003eUmożliwiając zorganizowane, bezpieczne zakończenie przewodów, chroni delikatne niskonapięciowe sygnały diagnostyczne przed degradacją i sprzężeniem szumów pojemnościowych. Zaprojektowany do niezawodnej pracy w trudnych warunkach obudów panelowych, blok zawiera wyraźne fizyczne pasy izolacji oddzielające główne wyjścia monitorujące od wtórnych linii instrumentów rejestrujących. \u003cstrong\u003e-01\u003c\/strong\u003e oznaczenie opcji określa standardowy wariant sprzętu bazowego, zapewniając stały układ konfiguracji, standardowe przypisania pinów oraz domyślną kompatybilność montażu mechanicznego z wyspecjalizowanymi szafami ochrony zakładu.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDwufunkcyjna architektura zakończeń łącząca główne ścieżki wejścia\/wyjścia przetwornika z niezależnymi wyjściami zacisków rejestrujących.\u003c\/li\u003e\n\u003cli\u003eBloki zaciskowe śrubowe lub sprężynowe zapewniające odporne na wibracje połączenia okablowania dla przewodów polowych.\u003c\/li\u003e\n\u003cli\u003eWyraźne fizyczne pasy separacji sprzętu zapobiegające przesłuchom sygnałów i zakłóceniom kanałów.\u003c\/li\u003e\n\u003cli\u003eUproszczony profil integracji panelu optymalizujący wykorzystanie przestrzeni wewnątrz lokalnych szaf łączeniowych.\u003c\/li\u003e\n\u003cli\u003eWytrzymała konstrukcja fizyczna zaprojektowana do ciągłej pracy na wymagających, wysoko wibracyjnych platformach pomocniczych zakładu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWysokogęstościowe zakończenie okablowania polowego dla sond zbliżeniowych i czujników obudowy monitorujących krytyczne turbomaszyny.\u003c\/li\u003e\n\u003cli\u003eCzyste prowadzenie sygnałów diagnostycznych z szaf ochrony maszyn do ciągłych bezpapierowych rejestratorów lub wejść systemu archiwizacji zakładu.\u003c\/li\u003e\n\u003cli\u003eStrukturalne łączenie instrumentacji w centralizowanych obudowach ochrony majątku i strefach granicznych obszarów niebezpiecznych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReferencja zamówienia produktu\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modelu bazowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81546 (Wejścia\/wyjścia przetwornika i zaciski rejestrujące)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKod pełnego montażu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81546-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlok sufiksu pełnej opcji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01 (Standardowa konfiguracja i opcja podstawy montażowej)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81546-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł wejścia\/wyjścia i zakończenia rejestracji przetwornika (XDCR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp połączenia przewodów\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzemysłowe bloki zaciskowe śrubowe lub listwy zaciskowe typu zaciskowego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfil kompatybilności sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNiskonapięciowe dynamiczne przebiegi drgań, położenia i prędkości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStopień izolacji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFizyczne oddzielenie kanałów i ekranowanie ścieżek obwodów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLiczba ścieżek rejestracji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSkonfigurowany do niezależnych wtórnych wyjść rejestrujących\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKonfiguracja montażu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01 Specyficzny rozmiar podstawy\/podstawy obudowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfil materiału obudowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzeźroczysta, ognioodporna polimerowa lub wzmacniana szklano-epoksydowa płyta tylna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptymalizacja torów sprzętowych\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNiskoprofilowy układ zaprojektowany dla strukturalnych paneli rozdzielczych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakresy temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardowa obudowa przemysłowa przystosowana do ograniczonych zakresów cieplnych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWzorzec wagi operacyjnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWaga standardowego przemysłowego bloku zaciskowego do podłączeń polowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eGrupa zacisków\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWejście przetwornika (XDCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunkty zaciskowe dla surowych przewodów czujników polowych (Zasilanie, Sygnał, Komunikacja)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŚcieżka I\/O monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane linie wyjściowe podłączone bezpośrednio do głównego stelaża ochronnego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZaciski rejestracyjne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRównoległe, izolowane wyjścia do zewnętrznych rejestratorów diagnostycznych i loggerów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEkran\/Uziemienie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWspólne punkty uziemienia ramy do podłączania przewodów uziemiających ekranów kabli przychodzących\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMontaż panelu rozdzielczego:\u003c\/strong\u003e Solidnie przymocuj obudowę bloku zaciskowego do wyznaczonego wewnętrznego stelaża lub płyty tylnej obudowy. Upewnij się, że wszystkie elementy mocujące są całkowicie dokręcone, aby przeciwdziałać lokalnym drganiom strukturalnym.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePodłączenie przewodów przetwornika:\u003c\/strong\u003e Odsłoń przewody czujników zgodnie ze standardowymi specyfikacjami inżynierskimi i podłącz je do zacisków XDCR. Dokładnie dokręć śruby, aby zapewnić ciągły kontakt elektryczny bez uszkodzenia izolacji przewodu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOddzielenie linii sygnałowych:\u003c\/strong\u003e Prowadź wtórne kable rejestrujące z dala od linii silników prądu przemiennego o wysokim napięciu lub ciężkich przekaźników przełączających w panelu, aby wyeliminować wprowadzanie zakłóceń elektromagnetycznych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUziemienie przewodu ekranowego:\u003c\/strong\u003e Podłącz przewody uziemiające ekranu kabla przychodzącego do wyznaczonych punktów zacisków ekranu, aby ustanowić jednolity punkt uziemienia panelu i zapobiec pętlom uziemienia.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847199595,"sku":"81546-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81546-01-xdcr-i-o-and-record-terminals-qleh4l44are_5a17253a-6dc8-4d4a-a55e-6f41284e3088.jpg?v=1765448948"},{"product_id":"bently-nevada-3500-61-02-00-133827-02-temperature-monitor-rtd-tc-non-isolated-i-o-module","title":"Moduł Wejścia\/Wyjścia Nieizolowany Monitor Temperatury RTD\/TC Bently Nevada 3500\/61-02-00 133827-02","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e3500\/61-02-00\u003c\/strong\u003e to sześciokanałowy moduł monitorowania temperatury zaprojektowany dla \u003cstrong\u003esystemu ochrony maszyn Bently Nevada 3500\u003c\/strong\u003e. Moduł akceptuje zarówno wejścia temperatury RTD, jak i termoparowe oraz wykonuje ciągły pomiar temperatury i funkcje porównania alarmów dla krytycznych zastosowań maszyn obrotowych.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e133827-02\u003c\/strong\u003e Moduł I\/O RTD\/TC nieizolowany używa zewnętrznych zakończeń i obsługuje mieszane konfiguracje wejść RTD i TC. Użytkownicy mogą konfigurować poszczególne kanały przez oprogramowanie do konfiguracji szafy 3500 do pracy z RTD lub termoparą.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/61\u003c\/strong\u003e seria różni się od \u003cstrong\u003e3500\/60\u003c\/strong\u003e poprzez zapewnienie wyjść rejestratora dla każdego kanału monitorującego. Wyjścia rejestratora obsługują transmisję 4 do 20 mA proporcjonalną do skonfigurowanego zakresu pełnej skali monitora.\u003c\/p\u003e\n\u003cp\u003eModuł obsługuje do sześciu wejść przetworników i zapewnia programowalne progi alarmów Alert i Danger. W systemach potrójnej redundancji modularnej (TMR) monitory temperatury instalowane są w grupach po trzy, aby wspierać redundantną logikę głosowania i tolerancję błędów.\u003c\/p\u003e\n\u003cp\u003eModuł nadaje się do systemów monitorowania turbin, zespołów sprężarek, zakładów procesowych, obiektów wytwarzania energii oraz zastosowań ochrony maszyn przemysłowych wymagających nadzoru temperatury i przetwarzania alarmów.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSześciokanałowy monitoring temperatury\u003c\/li\u003e\n\u003cli\u003eObsługuje wejścia RTD i termopary\u003c\/li\u003e\n\u003cli\u003eObsługa mieszanej konfiguracji kanałów RTD i TC\u003c\/li\u003e\n\u003cli\u003eZewnętrzne zakończenia, nieizolowany projekt I\/O\u003c\/li\u003e\n\u003cli\u003eWyjścia rejestratora dla wszystkich sześciu kanałów\u003c\/li\u003e\n\u003cli\u003eUstawienia alarmów konfigurowane przez użytkownika\u003c\/li\u003e\n\u003cli\u003eTryb pomiaru RTD lub TC konfigurowany programowo\u003c\/li\u003e\n\u003cli\u003eKompatybilny z oprogramowaniem do konfiguracji szafy 3500\u003c\/li\u003e\n\u003cli\u003eObsługuje architekturę systemu TMR\u003c\/li\u003e\n\u003cli\u003eDiody LED na panelu przednim: OK, TX\/RX i Bypass\u003c\/li\u003e\n\u003cli\u003eWyjścia rejestratora 4 do 20 mA\u003c\/li\u003e\n\u003cli\u003eKonfiguracja pełnej skali kanału przez oprogramowanie\u003c\/li\u003e\n\u003cli\u003eNie wymaga kalibracji\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitorowanie temperatury turbin parowych\u003c\/li\u003e\n\u003cli\u003eSystemy ochrony turbin gazowych\u003c\/li\u003e\n\u003cli\u003eNadzór temperatury sprężarek\u003c\/li\u003e\n\u003cli\u003eMonitorowanie przemysłowych maszyn obrotowych\u003c\/li\u003e\n\u003cli\u003eSystemy zatrzymania zakładów procesowych\u003c\/li\u003e\n\u003cli\u003eOchrona urządzeń do wytwarzania energii\u003c\/li\u003e\n\u003cli\u003eMonitorowanie procesów petrochemicznych\u003c\/li\u003e\n\u003cli\u003eMonitorowanie maszyn w obiektach LNG\u003c\/li\u003e\n\u003cli\u003eSystemy alarmowe krytycznego sprzętu\u003c\/li\u003e\n\u003cli\u003eInstalacje ochrony maszyn TMR\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/61-02-00: Kompletny zestaw monitora RTD\/TC z zewnętrznymi zakończeniami\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOkreśla zestaw łączony zawierający główny moduł monitora 3500\/61 oraz specyficzną nieizolowaną tylną płytkę I\/O.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: Opcja typu modułu I\/O\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eModuł I\/O RTD\/TC nieizolowany z zewnętrznymi zakończeniami (numer części tylnej płytki: \u003cstrong\u003e133827-02\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Opcja zatwierdzenia agencji\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNie wymagane zatwierdzenia ani certyfikaty agencji stref zagrożonych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCzęści zamienne i akcesoria\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNumer części \u003cstrong\u003e133827-02\u003c\/strong\u003e: Moduł I\/O RTD\/TC nieizolowany 3500\/61 do wymiany z zewnętrznymi zakończeniami.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eKategoria\u003c\/th\u003e\n\u003cth\u003eSpecyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp produktu\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O monitora temperatury RTD\/TC nieizolowany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeria\u003c\/td\u003e\n\u003ctd\u003eSeria 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/61-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer części zamiennej\u003c\/td\u003e\n\u003ctd\u003e133827-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKanały wejściowe\u003c\/td\u003e\n\u003ctd\u003e1 do 6 sygnałów przetworników RTD lub TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedancja wejściowa\u003c\/td\u003e\n\u003ctd\u003e10 MΩ na każde wejście przewodu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZużycie energii\u003c\/td\u003e\n\u003ctd\u003eNominalnie 9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWyjście rejestratora\u003c\/td\u003e\n\u003ctd\u003e+4 do +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNapięcie zgodności\u003c\/td\u003e\n\u003ctd\u003e0 do +12 V DC na obciążeniu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpór obciążenia\u003c\/td\u003e\n\u003ctd\u003e0 do 600 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRozdzielczość\u003c\/td\u003e\n\u003ctd\u003e0,3662 uA na bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eŹródło prądu RTD\u003c\/td\u003e\n\u003ctd\u003e925 +\/-15 uA przy 25°C na przetwornik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres opóźnienia alarmu\u003c\/td\u003e\n\u003ctd\u003eAlert: 1 do 60 s, Niebezpieczeństwo: 1 do 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary monitora\u003c\/td\u003e\n\u003ctd\u003e241,3 x 24,4 x 241,8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga monitora\u003c\/td\u003e\n\u003ctd\u003e0,91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary modułu I\/O\u003c\/td\u003e\n\u003ctd\u003e241,3 x 24,4 x 99,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga modułu I\/O\u003c\/td\u003e\n\u003ctd\u003e0,45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymaganie dotyczące slotu w szafie\u003c\/td\u003e\n\u003ctd\u003e1 pełnowysokościowy przedni slot i 1 tylny slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePochodzenie\u003c\/td\u003e\n\u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje RTD\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp RTD\u003c\/td\u003e\n\u003ctd\u003eZakres pomiarowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 omów RTD platynowy alfa 0,00385\u003c\/td\u003e\n\u003ctd\u003e-200°C do +850°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 omów RTD platynowy alfa 0,00392\u003c\/td\u003e\n\u003ctd\u003e-200°C do +700°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 omów RTD niklowy\u003c\/td\u003e\n\u003ctd\u003e-80°C do +260°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 omów RTD miedziany\u003c\/td\u003e\n\u003ctd\u003e-100°C do +260°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje termopary\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp termopary\u003c\/td\u003e\n\u003ctd\u003eZakres pomiarowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp E\u003c\/td\u003e\n\u003ctd\u003e-100°C do +1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp J\u003c\/td\u003e\n\u003ctd\u003e-18°C do +760°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp K\u003c\/td\u003e\n\u003ctd\u003e-18°C do +1370°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp T\u003c\/td\u003e\n\u003ctd\u003e-160°C do +400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje kondycjonowania sygnału\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametr\u003c\/td\u003e\n\u003ctd\u003eSpecyfikacja\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRozdzielczość RTD i termopary\u003c\/td\u003e\n\u003ctd\u003e1°C lub 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRozdzielczość RTD miedzianego\u003c\/td\u003e\n\u003ctd\u003e1°C lub 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDokładność kompensacji zimnego złącza\u003c\/td\u003e\n\u003ctd\u003e+\/-1°C przy 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDokładność alarmu\u003c\/td\u003e\n\u003ctd\u003eW granicach 0,13% wartości docelowej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDokładność zewnętrznego zakończenia nieizolowanego\u003c\/td\u003e\n\u003ctd\u003e+\/-1°C przy 25°C standardowej szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDokładność szafy przelotowej\u003c\/td\u003e\n\u003ctd\u003e+\/-3°C przy 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWyjścia i wskaźniki\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWskaźnik lub wyjście\u003c\/td\u003e\n\u003ctd\u003eFunkcja\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDioda OK\u003c\/td\u003e\n\u003ctd\u003eWskazuje prawidłową pracę monitora\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDioda TX\/RX\u003c\/td\u003e\n\u003ctd\u003eWskazuje komunikację z modułami szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDioda LED obejścia\u003c\/td\u003e\n\u003ctd\u003eWskazuje tryb obejścia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWyjścia rejestratora\u003c\/td\u003e\n\u003ctd\u003eIndywidualne wyjścia 4 do 20 mA na kanał\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUwagi inżynierskie\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWybór Platinum RTD\u003c\/strong\u003e: Platinum RTD z współczynnikiem alfa 0,00385 spełniają globalne standardy przemysłowe i są zalecane do wszystkich nowych instalacji pętli temperaturowych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOdporność rejestratora na zwarcia\u003c\/strong\u003e: Wewnętrzne obwody gwarantują, że podstawowy monitoring maszyn i logika alarmowa pozostają nienaruszone przez zwarcia w zewnętrznych pętlach rejestratora.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePróg dolny i górny\u003c\/strong\u003e: Wewnętrzny procesor zapewnia zarówno górne, jak i dolne granice alarmowe dla ochrony wielokierunkowej (np. stany kriogeniczne lub przegrzania).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWymagania TMR\u003c\/strong\u003e: Przy konfiguracji na potrójną modularną redundancję trzy identyczne monitory temperatury muszą znajdować się w kolejnych, sąsiadujących gniazdach przedniego panelu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWytyczne terenowe\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOkablowanie zewnętrznego zakończenia\u003c\/strong\u003e: Prowadź wszystkie przewody RTD lub termopary do zewnętrznego bloku zaciskowego, zapewniając czyste, gazoszczelne połączenia dla utrzymania dokładności CJC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUziemienie ekranów\u003c\/strong\u003e: Ekrany kabli należy zakończyć wyłącznie na wyznaczonym zacisku uziemienia ekranu w module I\/O, aby zapobiec pętlom masy i chronić przed zakłóceniami elektromagnetycznymi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDopasowanie czujnika CJC\u003c\/strong\u003e: Upewnij się, że czujnik kompensacji zimnego złącza jest solidnie zamocowany do podstawy zacisku, aby zapewnić dokładną kompensację otoczenia podczas pomiarów termoparą.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimalizacja rezystancji przewodów\u003c\/strong\u003e: W przypadku podłączeń RTD 3- i 4-przewodowych utrzymuj jednakową długość przewodów, aby zrównoważyć spadek napięcia i zapewnić dokładną kompensację mostka.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne i dotyczące zamówień\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jaka jest podstawowa różnica między modułami 3500\/60 a 3500\/61?\u003c\/strong\u003e O: Oba moduły oferują identyczny monitoring temperatury i logikę alarmową, ale 3500\/61 posiada sześć niezależnych wyjść rejestratora +4 do +20 mA, których 3500\/60 nie ma.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy ta konkretna opcja modułu I\/O bez izolacji zapewnia izolację kanał do kanału?\u003c\/strong\u003e O: Nie, to jest opcja 02, która nie jest izolowana; jeśli potrzebna jest izolacja kanał do kanału, aby przeciwdziałać silnym usterkom uziemienia lub przepięciom linii wysokiego napięcia, należy zamiast tego wybrać wersję modułu I\/O z izolacją.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy kalibracja w terenie jest wymagana dla modułu 3500\/61 podczas instalacji?\u003c\/strong\u003e O: Nie jest wymagana kalibracja w terenie, ponieważ zakresy pełnej skali i typy czujników są konfigurowane cyfrowo za pomocą oprogramowania 3500 Rack Configuration Software.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847691115,"sku":"3500\/61-02-00 133827-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-02-00-133827-02-rtd-tc-temperature-i-o-module-tul1fywpxs1_6cd7fe54-1ece-464e-8d43-bdb06cb565fb.jpg?v=1765448969"},{"product_id":"bently-nevada-3500-33-04-00-149992-04-low-current-16-channel-failsafe-relay-output-module","title":"Bently Nevada 3500\/33-04-00 149992-04 Low Current 16-Channel Failsafe Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/33-04-00 149992-04\u003c\/strong\u003e is a \u003cstrong\u003e16-channel failsafe relay output module\u003c\/strong\u003e used as a main or spare module in \u003cstrong\u003e3500 machinery protection systems\u003c\/strong\u003e. It provides 16 independently programmable relay outputs with alarm drive logic, supporting AND\/OR logic combinations of alert, danger, Not-OK statuses, and measured variables from any monitor channel. Each relay output can perform voting logic and integrates with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module interfaces with \u003cstrong\u003ePLC, DCS, SIS, and TSI systems\u003c\/strong\u003e, offering both normally de-energized (ND) and normally energized (NE) operation selectable in four groups of four channels. Front-panel LEDs indicate module status, communication activity, and channel alarm states.\u003c\/p\u003e\n\u003cp\u003eIt supports low current switching applications with gold-plated contacts, suitable for standard, failsafe, or hazardous area configurations. Module compatibility includes installation to the right of the Transient Data Interface (TDI) in a \u003cstrong\u003e3500 rack\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 relay outputs with independent programmable logic\u003c\/li\u003e\n\u003cli\u003eAlarm drive logic using AND\/OR conditions\u003c\/li\u003e\n\u003cli\u003eSelectable normally de-energized (ND) or normally energized (NE) operation\u003c\/li\u003e\n\u003cli\u003eFront-panel LEDs for OK, TX\/RX, and channel alarm status\u003c\/li\u003e\n\u003cli\u003eEpoxy-sealed relays with arc suppressors (250 Vrms)\u003c\/li\u003e\n\u003cli\u003eRelay life up to 10,000 cycles\u003c\/li\u003e\n\u003cli\u003eLow current gold-plated contact option for 1 mA @ 1 Vdc minimum load\u003c\/li\u003e\n\u003cli\u003eCompatible with 3500 Rack Configuration Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial machinery monitoring and protection\u003c\/li\u003e\n\u003cli\u003eProcess automation alarm outputs\u003c\/li\u003e\n\u003cli\u003eHazardous area relay interfacing\u003c\/li\u003e\n\u003cli\u003eIntegration with PLC, DCS, SIS, TSI systems\u003c\/li\u003e\n\u003cli\u003eLow-current signal switching in control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/33-04-00: Complete 16-Channel Relay Module Assembly\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifies the pre-configured combination consisting of the front main module card and the rear low-current failsafe output board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04: Output Module Type Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLow Current 16-Channel Failsafe Relay Output Module featuring gold-plated contacts (Rear I\/O Module Spare: \u003cstrong\u003e149992-04\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Hazardous Area Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo hazardous area agency approvals or certifications required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpares \u0026amp; Accessories\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number \u003cstrong\u003e149992-04\u003c\/strong\u003e: Spare 16-Channel Low Current Failsafe Relay Output Module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMain module: 0.7 kg (1.6 lb), I\/O module: 0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMain module: 241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in), I\/O module: 241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003eMain: 1 full-height front slot, I\/O: 1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSPDT (Single-pole Double-throw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Arc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003eStandard: 100 mA @ 5 Vdc, Low Current: 1 mA @ 1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003eDC: 5 A, AC: 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Power\u003c\/td\u003e\n\u003ctd\u003eDC: 70 W @ 24 Vdc, AC: 1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003eDC: 125 Vdc, AC: 250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eOK, TX\/RX, CH Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/D-Agent_1-_work-77-s-Upload-162096J1.pdf?v=1780026391\"\u003eRefer to 3500 rack manual\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay outputs, power, communication connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eGrounding and Shielding\u003c\/h4\u003e\n\u003cp\u003eEnsure the rack frame is properly tied to the plant instrumentation ground before inserting modules. Field wiring shields should be terminated at the designated shield terminals on the I\/O module to minimize electromagnetic interference and ensure signal integrity.\u003c\/p\u003e\n\u003ch4\u003eHazardous Area Precautions\u003c\/h4\u003e\n\u003cp\u003eDo not disconnect field wiring or module connections while the circuit is live unless the location is verified to be non-hazardous. Live handling in explosive atmospheres can result in arc-induced ignition risks.\u003c\/p\u003e\n\u003ch4\u003eModule Placement\u003c\/h4\u003e\n\u003cp\u003eAlign the main module with the chosen front slot to the right of the TDI module. Slide it firmly into the backplane connectors and tighten the panel screws. Install the matching I\/O module in the corresponding slot directly on the rear of the rack assembly.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 04 option signify in this module part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e The 04 code specifies that this is the Low Current 16-Channel Failsafe variant equipped with gold-plated contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum current rating for the gold-plated contact version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum switched current rating is 1 mA @ 1 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix the configuration for Normally Energized and Normally De-energized modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the sixteen channels are split into four distinct groups of four channels, and each group is independently switch-selectable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the TX\/RX LED on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TX\/RX LED flashes to indicate active transmission and reception of communication data between this module and other rack modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware package contain built-in spark protection for the contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, an internal 250 Vrms epoxy-sealed relay arc suppressor is standard equipment on the hardware channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit process individual variables from multiple monitor modules at once?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the Alarm Drive Logic can combine Alert, Danger, or Not-OK inputs from any monitor channel or combination of monitor channels within the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software tool is required to configure the voting logic pathways?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system logic is engineered and uploaded using the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the relay operation if the module encounters an internal failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Failsafe design ensures that when a major failure or loss of control occurs, the relays drop to their safe de-energized or default state depending on wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to exceed 5 mA when using an AC supply voltage up to 120Vac?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, currents exceeding 5 mA on these low-current gold relays will degrade or permanently damage the contact plating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many slots does the complete main and I\/O assembly take up?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt occupies one full-height slot on the front of the rack and one corresponding full-height slot on the rear panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I plug this module into the slot immediately adjacent to the power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt must be placed in any available slot situated to the right of the Transient Data Interface module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a solid light on the OK LED indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA solid light confirms that the hardware is powered up, has passed initial self-tests, and is operating properly.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848837995,"sku":"3500\/33-04-00 149992-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-04-00-149992-04-relay-i-o-module-fkulr4tcehu_c36c9898-9ec7-4d81-a6b1-b3299e531e38.jpg?v=1765448997"},{"product_id":"bently-nevada-3500-15-04-04-01-133300-01-legacy-low-voltage-dc-power-input-module","title":"Moduł wejściowy niskiego napięcia DC Bently Nevada 3500\/15-04-04-01 133300-01 Legacy","description":"\u003cp style=\"color: #2d3748;\"\u003e\u003cstrong\u003eBently Nevada 3500\/15-04-04-01\u003c\/strong\u003e, działający w ścisłej współpracy z tylnym interfejsem \u003cstrong\u003e133300-01\u003c\/strong\u003e, to przemysłowy półwysokościowy moduł konwersji zasilania zaprojektowany dla systemu ochrony maszyn serii 3500. Ta specyficzna kombinacja sprzętowa tworzy legacy infrastrukturę wejściową niskonapięciowego prądu stałego, odbierając surowe wektory zasilania zakładowego i wykonując wysoką izolację oraz regulację obniżającą napięcie, aby zasilać wewnętrzne pasywne szyny backplane z ściśle monitorowanymi potencjałami operacyjnymi DC.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eKluczowe cechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePrawdziwa topologia redundantna N+1:\u003c\/strong\u003e Wspiera ciągłe przydzielanie podwójnego zasilania w pojedynczej konfiguracji szafy, gdzie dolna zatoka działa jako główne źródło zasilania, a górna jako nieprzerwana jednostka zapasowa na gorąco.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMożliwość wymiany na gorąco bez przestojów:\u003c\/strong\u003e Wewnętrzne obwody dynamicznego wyrównania pozwalają na fizyczne usunięcie lub włożenie dowolnej karty zasilania, podczas gdy szafa monitorująca maszyny pozostaje w pełni zasilana, zapobiegając fałszywym wyłączeniom lub martwym strefom ochrony.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBariera izolacji galwanicznej:\u003c\/strong\u003e Zaprojektowana z mocno oddzielonymi ścieżkami obwodów między zaciskami wejściowymi a połączeniami backplane, aby pochłaniać duże przepięcia napięciowe po stronie pola i fluktuacje pętli masy.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedykowany moduł wejściowy zasilania (PIM):\u003c\/strong\u003e Sparowany z tylnym modułem legacy 133300-01 wyposażonym w solidne bloki zaciskowe i zoptymalizowane filtry wejściowe dedykowane niskonapięciowym bankom baterii.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eKrytyczna ochrona turbin maszynowych:\u003c\/strong\u003e Dostarcza stabilne szyny operacyjne dla krytycznych modułów monitorowania drgań wału, pozycji osi i prędkości w zespołach turbin parowych i gazowych.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIntegracja z bankiem baterii zakładowych:\u003c\/strong\u003e Bezpośrednie połączenie z centralnymi przemysłowymi systemami zasilania awaryjnego 24V DC w zakładach wytwarzania energii i przetwórstwa petrochemicznego.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSzafy sterownicze o wysokiej dostępności:\u003c\/strong\u003e Wdrożenie w zdalnych obudowach maszyn wymagających maksymalnej dostępności systemu dzięki redundantnemu zasilaniu instrumentów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eKod opcji\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eSzczegóły wyboru inżynieryjnego\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003eKonfiguracja bazowa 3500\/15-AA-BB-CC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eAA - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZasilacz niskonapięciowy DC Legacy (zakres 20 do 30 Vdc)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eBB - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł wejściowy niskonapięciowego zasilania stałoprądowego (PIM) Legacy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eCC - 01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOpcja zatwierdzenia agencji: CSA-c-US (Klasa I, Podział 2, Grupy A, B, C, D)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003eNumery części rozbicia komponentów\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e106M1081-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZespół głównej karty zasilacza niskonapięciowego DC Legacy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e133300-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł wejściowy niskonapięciowego zasilania stałoprądowego (PIM) tylny sprzęt\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eParametr techniczny\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eZweryfikowana wartość inżynieryjna\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres napięcia wejściowego\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZakres napięcia wejściowego 20 V DC do 30 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaksymalny prąd wejściowy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10,0 A ciągłego prądu\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTypowe zużycie energii\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMaksymalna moc 230 W przy pełnym obciążeniu obudowy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRegulowane szyny wyjściowe\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+5 V DC, -5 V DC, +15 V DC, -15 V DC rozprowadzane przez pasywną płytę tylną\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWytrzymałość dielektryczna izolacji\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRezystancja izolacji terminalu 500 V DC do uziemienia obudowy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRozmiar formatu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUkład karty o połowie wysokości (zajmuje określone lewe sloty w stojaku)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres temperatury pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 stopni Celsjusza do +65 stopni Celsjusza\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres temperatury przechowywania\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 stopni Celsjusza do +85 stopni Celsjusza\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres wilgotności względnej\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDo 95% wilgotności względnej, bez kondensacji\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMonitorowanie stanu na panelu przednim\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZintegrowana zielona matryca diod LED „Supply OK”\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (firma Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStany Zjednoczone\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga głównej karty zasilającej\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0,77 kg (1,70 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga tylnej karty wejściowej PIM\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0,31 kg (0,68 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCałkowita waga netto systemu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1,08 kg (2,38 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1,55 kg (kompletny system z podwójną kartą w pudełku)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWymiary opakowania (obliczone)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e285 mm x 210 mm x 155 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eOznaczenie zacisku\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003ePrzypisanie interfejsu obwodu\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDodatnia linia wejściowa DC (akceptuje napięcie odniesienia +20 do +30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUjemna linia powrotna DC (wspólna ścieżka powrotna obwodu zasilania)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eGND\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePołączenie uziemienia ochronnego (bezpośrednie połączenie metalowej ramy)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e Odizoluj główny wyłącznik obwodu zasilania 24V DC przed rozpoczęciem instalacji. Nie manipuluj ani nie podłączaj bezpośrednio przewodów zasilających do tylnego bloku zaciskowego 133300-01 pod napięciem. Mostkowanie przewodów pod napięciem grozi ciągłym powstawaniem łuku elektrycznego, wewnętrznymi zwarciami między warstwami miedzi oraz trwałą awarią wszystkich kart monitorujących na wspólnej płycie tylnej.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePodłącz zweryfikowaną antystatyczną opaskę na nadgarstek do niepomalowanej ramy stojaka, aby rozładować potencjalne ładunki elektrostatyczne przed otwarciem osłon modułów.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePłynnie wsunąć główną kartę zasilającą o połowie wysokości w dedykowane prowadnice na przedniej lewej stronie obudowy 3500, aż do połączenia z zespołem pinów tylnej płyty.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWyrównaj starą kartę zasilającą 133300-01 w równoległej tylnej zatoce. Dokładnie dokręć tylne śruby mocujące, aby zabezpieczyć jednostkę przed trwałymi wibracjami mechanicznymi.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eOdsłoń kable zasilające o 7 milimetrów, mocno włóż je do zacisku terminala DC, dopasowując do zweryfikowanych biegunowości, i dokręć śruby zaciskowe zgodnie ze specyfikacją momentu obrotowego.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850673003,"sku":"3500\/15-04-04-01 133300-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-04-04-01-133300-01-low-voltage-dc-power-input-module-jkcdk13hega_bc249377-abc5-4e7b-890f-e8d2efa9342f.jpg?v=1765449036"},{"product_id":"bently-nevada-3300-30-six-channel-temperature-tc-input-monitor","title":"Bently Nevada 3300\/30 Sześciokanałowy monitor temperatury z wejściem termoparowym","description":"\u003cp\u003eModuł\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/30 sześciokanałowy monitor temperatury\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto sześciokanałowy moduł monitorowania temperatury zaprojektowany dla starszego systemu\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eTa wersja jest specjalnie skonfigurowana do przyjmowania\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewejść termoparowych (TC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ezamiast czujników RTD.\u003c\/p\u003e\n\u003cp\u003eJest powszechnie używany do monitorowania krytycznych punktów temperaturowych w maszynach przemysłowych, w tym:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTemperatura metalu łożyska\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperatura spalin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperatura uzwojenia stojana\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperatura układu oleju smarnego\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMonitor zapewnia ciągłą ochronę dzięki konfigurowalnym przekaźnikom alarmowym i standardowym wyjściom rejestratora, gwarantując niezawodne nadzorowanie termiczne w turbinach, sprężarkach i generatorach.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecyfikacje techniczne\u003c\/h2\u003e\n\u003ch3\u003e1. Wejścia\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePojemność wejściowa\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eObsługuje do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esześciu (6) niezależnych wejść termoparowych\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKażdy kanał działa niezależnie\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eObsługiwane typy termopar\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTyp\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Żelazo \/ Konstantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTyp\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Alumel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTyp\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Konstantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTyp\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Miedź \/ Konstantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKompensacja zimnego złącza\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWewnętrzna kompensacja zapewniona na bloku zaciskowym\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatycznie koryguje dryft pomiaru spowodowany zmianami temperatury otoczenia\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZapewnia stabilną dokładność temperatury w różnych warunkach pracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Kondycjonowanie sygnału\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDokładność\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eW granicach\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±2,2% sygnału\u003c\/strong\u003e, plus tolerancja termopary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperatura odniesienia:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWykrywanie przerwania termopary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMonitor zawiera automatyczne wykrywanie awarii w przypadku przerwania obwodu termopary.\u003c\/p\u003e\n\u003cp\u003eWybieralne tryby reakcji:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSterowanie w górę\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Wymusza odczyt na wysoką wartość\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSterowanie w dół\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Wymusza odczyt na niską wartość\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTa funkcja zapobiega pracy maszyn bez ochrony temperaturowej.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSzybkość skanowania\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWszystkie sześć kanałów skanowanych około:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0,5 sekundy na cykl\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTa prędkość skanowania jest typowa dla systemów ochrony maszyn, gdzie zmiany temperatury zachodzą stopniowo w porównaniu do sygnałów drgań.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Wyjścia\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWyjścia rejestratora\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProgramowalne przez użytkownika wyjścia analogowe:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 do +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 do -10 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 do +5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuforowane wyjścia\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDostępne do celów diagnostycznych i monitorujących:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eZłącza koncentryczne na panelu przednim\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePołączenia zacisków tylnego bloku\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJedno buforowane wyjście na kanał\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTe wyjścia są zazwyczaj podłączone do:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSystemy DCS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystemy PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRejestratory danych\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOprogramowanie do monitorowania stanu\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. Alarmy i wyświetlacz\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWyświetlacz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWyświetlacz temperatury LCD 7-segmentowy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePokazuje wartość temperatury w czasie rzeczywistym\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWybór kanału:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUżyj przycisku\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWyświetlacz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrzełącza się między Kanałem 1 a Kanałem 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUstawienia alarmów\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKażdy kanał obsługuje niezależną konfigurację alarmu:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm ostrzegawczy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm niebezpieczeństwa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOba progi są w pełni regulowane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWskaźnik OK\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDiody LED OK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eciągle monitorują stan systemu, w tym:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eElektronika monitora\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCzujniki termoparowe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegralność okablowania w terenie\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInformacje o zamówieniu\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFormat zamówienia\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/30-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003chr\u003e\n\u003ch3\u003eA — Opcja pełnego zakresu\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eKod\u003c\/th\u003e\n\u003cth class=\"\"\u003eZakres temperatur\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0 do 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0 do 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0 do 500°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0 do 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e32 do 212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e32 do 392°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e32 do 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e32 do 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Opcja wejścia termopary\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eKod\u003c\/th\u003e\n\u003cth class=\"\"\u003eTyp termopary\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eTyp J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eTyp K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eTyp E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eTyp T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Opcja przekaźnika alarmowego\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eKod\u003c\/th\u003e\n\u003cth class=\"\"\u003eOpis\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak przekaźników\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003ePrzekaźnik zalany epoksydem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003ePrzekaźnik hermetycznie zamknięty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Opcja zatwierdzenia agencji\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eKod\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNie wymagane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eSamoświadectwo ATEX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Opcja bariery bezpieczeństwa\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eKod\u003c\/th\u003e\n\u003cth class=\"\"\u003eOpis\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003ePrzegrody zewnętrzne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003ePrzegrody wewnętrzne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003ePrzewodnik inżynieryjny i instalacyjny\u003c\/h2\u003e\n\u003ch3\u003eWymagania dotyczące miejsca\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMonitor temperatury 3300\/30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModuł o podwójnej szerokości\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWymagania instalacyjne:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eZajmuje\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edwa (2) sloty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ew stojaku 3300\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eJest to ważne przy planowaniu pojemności stojaka w projektach modernizacji lub rozbudowy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWymagania dotyczące przewodu termopary\u003c\/h3\u003e\n\u003cp\u003eZawsze używaj odpowiedniego\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprzewodu przedłużającego termopary\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ezgodnego z typem termopary.\u003c\/p\u003e\n\u003cp\u003ePrzykłady:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTyp K → Przewód przedłużający typu K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTyp J → Przewód przedłużający typu J\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUżycie standardowego przewodu miedzianego spowoduje:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBłędy napięcia złącza\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDryft pomiaru temperatury\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNiedokładność kalibracji\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo jeden z najczęstszych błędów podczas instalacji w terenie.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePraktyka uziemienia\u003c\/h3\u003e\n\u003cp\u003eZalecana metoda uziemienia:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUziemiaj ekran termopary tylko przy stojaku monitora\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnikaj uziemiania w wielu punktach.\u003c\/p\u003e\n\u003cp\u003eNieprawidłowe uziemienie może powodować:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePętle uziemienia\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSzum sygnału\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNiestabilne odczyty temperatury\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWymagana jest szczególna uwaga przy używaniu:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTermopary z uziemioną końcówką\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTe czujniki są bardziej wrażliwe na konfigurację uziemienia.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eKontrola środowiska zimnego złącza\u003c\/h3\u003e\n\u003cp\u003eNie instaluj stojaka monitora w miejscach z:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSzybkie zmiany temperatury\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSilny przepływ powietrza przez bloki zaciskowe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWysokie gradienty termiczne\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTe warunki mogą wpływać na dokładność wewnętrznej kompensacji zimnego złącza.\u003c\/p\u003e\n\u003cp\u003eTypowe problematyczne miejsca:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eW pobliżu kanałów wentylacyjnych\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBlisko ścieżek wydechowych turbiny\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePanele zewnętrzne bez izolacji termicznej\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850935147,"sku":"3300\/30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-30-position-monitor-module-aahygilvquw_7ed0cd2c-10d0-4b8c-b33c-9c8d65d61045.jpg?v=1765449041"},{"product_id":"bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbus-i-o-module","title":"Moduł I\/O Ethernet\/RS232 Modbus Bently Nevada 3500\/92-03-01-00 136188-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/92-03-01-00\u003c\/strong\u003e to \u003cstrong\u003emoduł bramy komunikacyjnej\u003c\/strong\u003e zaprojektowany dla \u003cstrong\u003esystemu ochrony maszyn serii 3500\u003c\/strong\u003e. Jego głównym celem jest zapewnienie ciągłej, szybkiej komunikacji dla wszystkich wartości i statusów monitorowanych w szafie, umożliwiając płynną integrację z rozproszonymi systemami sterowania (DCS), programowalnymi sterownikami logicznymi (PLC), interfejsami człowiek-maszyna (HMI) oraz innymi systemami automatyzacji zakładu.\u003c\/p\u003e\n\u003cp\u003eModuł posiada kompleksowe interfejsy komunikacyjne, wykorzystujące zarówno Ethernet TCP\/IP, jak i kanały szeregowe (RS232) za pośrednictwem \u003cstrong\u003emodułu I\/O 136188-01\u003c\/strong\u003e. Obsługuje wewnętrzne zbieranie danych, pobierając aktualne wartości pomiarowe, oznaczenia czasowe, statusy modułów oraz statusy alarmów z innych modułów monitorujących w szafie przez wysokowydajną sieć wewnętrzną. Dodatkowo, \u003cstrong\u003e3500\/92\u003c\/strong\u003e obsługuje bezpośrednią komunikację Ethernet z autorskim \u003cstrong\u003eoprogramowaniem konfiguracyjnym 3500 Rack\u003c\/strong\u003e oraz \u003cstrong\u003eoprogramowaniem do akwizycji danych\u003c\/strong\u003e. Ta konkretna wersja posiada konfigurowalne narzędzie Modbus Register Utility do efektywnego mapowania danych systemowych w sieciach automatyki nadrzędnej.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCiągłe zbieranie danych z szafy, w tym aktualnych wartości pomiarowych z oznaczeniami czasowymi, statusów modułów i alarmów.\u003c\/li\u003e\n\u003cli\u003eMożliwość jednoczesnej komunikacji przez Ethernet TCP\/IP i łącza szeregowe.\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne narzędzie Modbus Register Utility do dostosowywania mapowania rejestrów dla systemów nadrzędnych.\u003c\/li\u003e\n\u003cli\u003eWysokowydajna wewnętrzna sieć z szybkością zbierania danych, która aktualizuje wszystkie moduły w szafie w mniej niż 1 sekundę.\u003c\/li\u003e\n\u003cli\u003eWskaźniki LED na panelu przednim do natychmiastowego monitorowania statusu pracy modułu (OK) i aktywności komunikacji (TX\/RX).\u003c\/li\u003e\n\u003cli\u003eWsteczna kompatybilność z funkcjami oprogramowania oryginalnego modułu 3500\/90.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegracja monitorowania drgań i stanu turbin parowych i gazowych.\u003c\/li\u003e\n\u003cli\u003eTransmisja danych ochrony sprężarek i pomp do systemu DCS zakładu.\u003c\/li\u003e\n\u003cli\u003eSieci monitorowania stanu maszyn przemysłowych i predykcyjnej konserwacji.\u003c\/li\u003e\n\u003cli\u003eSynchronizacja automatyzacji elektrowni i zakładów petrochemicznych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3500\/92: Brama komunikacyjna\u003c\/li\u003e\n\u003cli\u003e03: Moduł I\/O Ethernet\/RS232 Modbus\u003c\/li\u003e\n\u003cli\u003e01: Niska pamięć\u003c\/li\u003e\n\u003cli\u003e00: Brak opcji zatwierdzenia agencji\u003c\/li\u003e\n\u003cli\u003e136188-01: Moduł I\/O Ethernet\/RS232 Modbus zapasowy (zawiera zestaw aktualizacji oprogramowania układowego 126M4118-01)\u003c\/li\u003e\n\u003cli\u003e126M4118-01: Zestaw aktualizacji oprogramowania układowego\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eTypowe zużycie mocy 5,0 W z modułem I\/O Modbus RS232\/RS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eTypy danych\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eAktualne wartości mierzone z sygnaturą czasową, statusy modułów, aktualne statusy alarmów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eCzas aktualizacji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eMniej niż 1 sekunda dla wszystkich modułów w szafie 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eWyjście diody OK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eWskazuje, kiedy 3500\/92 działa prawidłowo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eWyjście diody TX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eWskazuje, kiedy 3500\/92 komunikuje się z innymi modułami w szafie 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eProtokół hosta BNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003ePołączenie Ethernet TCP\/IP z oprogramowaniem 3500 Configuration and Data Acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eProtokół Modbus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eNa podstawie podręcznika AEG Modicon PI-MBUS-300, tryb transmisji Remote Terminal Unit (RTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003ePrędkość łącza Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e10 Mbps, zgodne z IEEE 802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eProtokół Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eRamka Ethernet TCP\/IP i Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003ePołączenie Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eRJ-45 do okablowania Ethernet 10BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-30°C do +65°C (-22°F do +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eWymiary płyty głównej (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e241 mm x 24,4 mm x 242 mm (9,50 in x 0,96 in x 9,52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eWymiary modułu I\/O (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e241 mm x 24,4 mm x 99,1 mm (9,50 in x 0,96 in x 3,90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eWaga płyty głównej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e0,82 kg (1,8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e0,44 kg (0,96 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003e\u003cstrong\u003eCałkowita waga zespołu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e1,26 kg (2,76 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003ePin złącza\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eGniazdo RJ-45\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eInterfejs Ethernet TCP\/IP 10BASE-T i Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003ePort szeregowy (RS232)\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eInterfejs komunikacji szeregowej Modicon Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeryfikacja oprogramowania układowego:\u003c\/strong\u003e Upewnij się, że starsze moduły główne Communication Gateway zostały zaktualizowane za pomocą zestawu aktualizacji oprogramowania układowego 126M4118-01 przed instalacją nowego modułu I\/O 136188-01.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWkładanie do szafy:\u003c\/strong\u003e Włóż płytę główną do wyznaczonego gniazda komunikacyjnego w szafie 3500, zapewniając pełne osadzenie i solidne dokręcenie śrub obudowy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyrównanie modułu I\/O:\u003c\/strong\u003e Zainstaluj moduł I\/O 136188-01 bezpośrednio za modułem głównym od tyłu szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOgraniczenia okablowania:\u003c\/strong\u003e Używaj standardowego okablowania Ethernet 10BASE-T z złączami RJ-45 do konfiguracji sieci, ograniczając długość kabli zgodnie z normą IEEE 802.3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKontrola środowiskowa:\u003c\/strong\u003e Upewnij się, że warunki pracy nie przekraczają 65°C i że drogi wentylacyjne w obudowie 3500 pozostają niezatkane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest funkcja modułu 3500\/92?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDziała jako brama komunikacyjna, eksportując dane z szafy ochrony maszyn 3500 do zewnętrznych systemów automatyki, takich jak PLC i DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie interfejsy są dostępne w module I\/O 136188-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZapewnia złącze Ethernet RJ-45 oraz interfejs szeregowy RS232.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie protokoły mogą działać przez połączenie Ethernet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eObsługuje protokół Modbus\/TCP oraz własny protokół hosta Bently Nevada dla aplikacji programowych.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzym ten moduł różni się od starszego modułu 3500\/90?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsuwa stałe rejestry Modbus wartości podstawowej i zastępuje je elastycznym narzędziem Configurable Modbus Register Utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak długo trwa odświeżenie danych z szafy przez moduł?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSzybkość zbierania danych zależy od konfiguracji, ale gwarantuje się, że nie przekroczy 1 sekundy dla wszystkich modułów.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie jest typowe zużycie energii dla tej konkretnej konfiguracji I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSystem zazwyczaj zużywa 5,0 W, gdy jest wyposażony w moduł I\/O Modbus RS232.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy mogę połączyć moje oprogramowanie 3500 Configuration przez tę bramkę?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, umożliwia komunikację Ethernet z pakietami oprogramowania 3500 Rack Configuration i Data Acquisition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo powinienem sprawdzić, jeśli dioda TX\/RX jest zgaszona?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSprawdź, czy moduł jest prawidłowo osadzony oraz czy wewnętrzna magistrala komunikacyjna szafy jest aktywna i działa poprawnie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy aktualizacja oprogramowania układowego jest obowiązkowa przy wymianie interfejsu 136188-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStarsze moduły głównej bramki wymagają aktualizacji oprogramowania układowego za pomocą zestawu 126M4118-01, aby prawidłowo rozpoznać nowy sprzęt I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie są ograniczenia dotyczące przechowywania tego sprzętu w środowisku?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł musi być przechowywany w zakresie temperatur otoczenia od -40°C do +85°C.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852540779,"sku":"3500\/92-03-01-00 136188-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbusi-o-module-p13m3rotikn_8ccc5100-a46c-4dba-8a08-f4cf661d45b3.jpg?v=1765449087"},{"product_id":"bently-nevada-3500-40m-125680-01-proximitor-i-o-module","title":"Moduł Wejścia\/Wyjścia Proximitor Bently Nevada 3500\/40M 125680-01","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-127\"\u003eModuł Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e125680-01\u003c\/strong\u003e\u003cspan class=\"citation-127 citation-end-127\"\u003e\u003cspan\u003e \u003c\/span\u003eto 4-kanałowy moduł I\/O Proximitor z wewnętrznymi zakończeniami, zaprojektowany dla systemu ochrony maszyn serii 3500.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUmieszczony w tylnym slocie szafy przyrządowej 3500, moduł ten pełni rolę bezpośredniego interfejsu sprzętowego łączącego zewnętrzne przetworniki zbliżeniowe prądów wirowych z przednim modułem monitorującym 3500\/40M Proximitor.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003eUrządzenie zapewnia stabilne wzbudzenie zasilania czujników, odbiera surowe analogowe napięcia przemieszczenia i kieruje te przetworzone sygnały do głównej karty procesora w celu obliczenia parametrów maszyn, takich jak drgania promieniowe, ekscentryczność wału, pozycja siły osiowej, rozszerzalność różnicowa i REBAM.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWyposażony we wbudowany blok zacisków śrubowych, model 125680-01 eliminuje potrzebę stosowania oddzielnych zewnętrznych paneli zakończeniowych, oszczędzając cenną przestrzeń w gęsto zabudowanych szafach sterowniczych.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40M (komponent tylny)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumer części \/ ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125680-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuł I\/O Proximitor (wewnętrzne zakończenia)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKompatybilność systemu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem ochrony maszyn serii 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePojemność kanałów\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kanały przetworników zbliżeniowych nieizolowanych\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedancja wejściowa sygnału\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kΩ dla wejść Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePołączenie zakończeniowe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWbudowany wielopozycyjny blok zacisków śrubowych\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypowe zużycie mocy 7,7 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWsparcie przetwornika\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3300 XL 8mm, 11mm i 25mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePomiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePomiar drgań promieniowych, siły osiowej, ekscentryczności, REBAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary (SxWxG)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24,4 mm x 241,3 mm x 99,1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga netto produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,20 kg (0,44 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStany Zjednoczone (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cp\u003eModyfikacje sprzętu do monitorowania turbin wymuszają sprawdzenie dokładnych numerów części zamiennych. Należy zamawiać wyłącznie zamienniki dokładnie odpowiadające kodom zamówień fabrycznych poniżej.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSufiks głównego komponentu systemu:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/40M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumer części zamówieniowej fabryki:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125680-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWariant rdzenia modułu:\u003c\/strong\u003e\u003cspan class=\"citation-125 citation-end-125\"\u003e\u003cspan\u003e \u003c\/span\u003eStandardowy moduł I\/O tylnego panelu o pełnej wysokości\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eUwagi inżynierskie i przewodnik po okablowaniu w terenie\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eUkład zakończenia sygnału przetwornika\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWewnętrzny blok zakończeniowy 125680-01 obsługuje do czterech zestawów czujników zbliżeniowych. Każda grupa kanałów sygnałowych zawiera trzy dedykowane zaciski śrubowe:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVTX \/ Prox (+):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSzyna zasilania przetwornika (zazwyczaj -24V DC do wzbudzenia).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG \/ In (S):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCiągłe analogowe surowe napięcie przerwy zwracane z czujnika Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM \/ Gnd (-):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWspólna linia odniesienia pomiarowego.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eZdejmij izolację przewodnika dokładnie na 7 mm. Używaj wysokiej jakości 3-żyłowych skręcanych ekranowanych kabli pomiarowych (miedź 18 AWG do 22 AWG), aby zapobiec anomaliom indukcji magnetycznej zniekształcającym sygnały wysokiej częstotliwości.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtokoły uziemienia ekranów kabli\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZakończ indywidualne zewnętrzne ekrany kabli na ramie obudowy 3500, aby zapobiec zakłóceniom EMI\/RFI. Linie ekranów muszą być związane i uziemione do niepomalowanego uziemienia ramy szafy za pomocą szerokiej zaciskowej uziemki.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNigdy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enie łącz ekranu kabla ze śrubami wspólnego sygnału (COM) bloku zaciskowego; powoduje to pętle uziemienia, które mogą maskować krytyczne drgania o dużej amplitudzie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOgraniczenia bezpieczeństwa przy wymianie na gorąco\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eArchitektura 3500 umożliwia wymianę na gorąco; jednak wyjęcie tylnego modułu I\/O natychmiast odcina zasilanie czujników w terenie, wywołując \"Monitor Fault\".\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePrzełącz przedni przełącznik blokady klucza szafy na\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etryb \"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-124\"\u003eWłącz kanał w oprogramowaniu\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eflagi pominięcia\u003c\/strong\u003e\u003cspan class=\"citation-124 citation-end-124\"\u003e\u003cspan\u003e \u003c\/span\u003eza pomocą oprogramowania do konfiguracji szafy 3500.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrzystąp do fizycznego demontażu, aby zapobiec aktywacji przekaźników awaryjnych w dalszych obwodach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ dotyczące konserwacji i rozwiązywania problemów\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Jaka jest podstawowa różnica między modułem 125680-01 a modułami z zewnętrznym zakończeniem?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Moduł 125680-01 posiada wbudowane zestawy zacisków śrubowych na tylnej płycie, umożliwiające bezpośrednie podłączenie okablowania terenowego do modułu. Warianty z zewnętrznym zakończeniem wymagają wysokogęstościowych wielopinowych taśmowych kabli do połączenia z oddzielnym panelem zacisków na szynie DIN zamontowanym w innym miejscu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Czy moduł 125680-01 może przyjmować sygnały z czujników zbliżeniowych innych niż Bently Nevada?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Nie. Wewnętrzne ścieżki i macierze skalowania są kalibrowane specjalnie dla przetworników zbliżeniowych Bently Nevada. Czujniki innych producentów zaburzą liniowe współczynniki skali, unieważniając konwersje pomiarów i generując błędy kalibracji.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Jak rozwiązywać problemy z pojedynczym kanałem, który stale pokazuje status \"NOT OK\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Zmierz surowe napięcie prądu stałego na przerwie między zaciskami SIG i COM za pomocą multimetru. Sprawny czujnik pokazuje napięcie między -4V DC a -16V DC. Jeśli napięcie jest bliskie 0V lub odzwierciedla pełne zasilanie -24V, usterka prawdopodobnie wynika z zwarcia lub przerwy w przewodzie w terenie, a nie z awarii modułu I\/O.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859290987,"sku":"125680-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125680-01-proximitor-i-o-module-nch0io30ar2_8104b65d-e1e6-431e-b4e2-7a9ec8d0e125.jpg?v=1765449252"},{"product_id":"bently-nevada-81544-01-3300-transducer-input-output-and-recorder-terminal-module","title":"Moduł terminala wejścia\/wyjścia i rejestratora przetwornika Bently Nevada 81544-01 3300","description":"\u003cp\u003eModuł terminalowy wejścia\/wyjścia przetwornika i rejestratora \u003cstrong\u003e81544-01\u003c\/strong\u003e, alternatywny numer fabryczny \u003cstrong\u003e78462-02\u003c\/strong\u003e, to komponent interfejsu montowany z tyłu, zaprojektowany wyłącznie dla podwójnego monitora różnicowego rozszerzalności Bently Nevada 3300\/45 w systemie nadzoru turbin. Moduł umożliwia dwukanałowe przesyłanie dynamicznych sygnałów wejściowych z dwóch oddzielnych zestawów przetworników sondy zbliżeniowej w celu oceny bezwzględnego przemieszczenia osiowego wirnika względem obudowy maszyny, spowodowanego rozszerzalnością cieplną podczas rozruchu i zatrzymania. Elektrycznie skonfigurowany z ustaloną impedancją wejściową 10 kΩ, wspiera logikę sterowania monitora, która przetwarza zarówno wielkość, jak i kierunek różnicowej rozszerzalności w czterech programowalnych progach alarmowych, składających się z dwóch progów nad-alarmowych i dwóch pod-alarmowych. Ta pasywna architektura terminala jest realizowana bez wbudowanych styków przekaźnikowych elektromechanicznych, działając zamiast tego jako bezpośredni przelot sygnału i centrum dystrybucji do rejestratora dla ciągłej ochrony maszyn.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje sprzętowe\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81544-01 (78462-02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeria produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKompatybilny moduł monitora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/45 Podwójny monitor różnicowej rozszerzalności\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLiczba kanałów\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 niezależne kanały (kanał B można wyłączyć)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfejs przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 sygnały z przetworników sondy zbliżeniowej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObsługa alarmów\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 progi łącznie (2 nad-alarmy, 2 pod-alarmy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKonfiguracja przekaźników\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrak wbudowanych przekaźników\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj produkcji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStany Zjednoczone (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUwagi inżynierskie\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImpedancja wejściowa 10 kΩ jest zoptymalizowana pod kątem dopasowania do parametrów wyjściowych standardowych czujników Proximitor firmy Bently Nevada, zapewniając brak degradacji sygnału w pomiarze różnicowej rozszerzalności.\u003c\/li\u003e\n\u003cli\u003eGdy wymagane są pomiary osiowe w pojedynczym punkcie na mniejszych obudowach maszyn, kanał B musi być programowo wyłączony w monitorze 3300\/45, aby zapobiec błędom napięcia przerwy obwodu.\u003c\/li\u003e\n\u003cli\u003ePonieważ 81544-01 nie zawiera przekaźników mechanicznych, wszystkie polecenia blokady alarmów i wyzwalania muszą być przetwarzane przez magistralę systemową do sąsiedniego modułu przekaźnikowego systemu 3300.\u003c\/li\u003e\n\u003cli\u003eZmiany rozszerzalności cieplnej podczas rozruchu turbiny zmieniają napięcie bazowe szczeliny; surowe wyjścia rejestratora z tego terminala odwzorowują te proporcjonalne przesunięcia DC do wykresów trendów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWytyczne montażowe\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZastosuj rygorystyczne uziemienie ekranu na wyznaczonym bloku zacisków, zapewniając, że zewnętrzny przewód odprowadzający ekranu kabla przedłużającego sondę zbliżeniową jest połączony z uziemieniem instrumentu, pozostając jednocześnie odizolowanym przy obudowie czujnika.\u003c\/li\u003e\n\u003cli\u003eUtrzymuj oddzielne trasy prowadzenia przewodów dla niskoomowych wejść czujników i sąsiednich obwodów sterowania prądem przemiennym wysokiego napięcia, aby uniknąć przesłuchów w obudowie panelu TSI.\u003c\/li\u003e\n\u003cli\u003ePrzed uruchomieniem sprawdź, czy śruby zacisków terminala są dokręcone zgodnie ze standardowymi specyfikacjami momentu, aby wyeliminować przerywane fluktuacje napięcia szczeliny spowodowane oporem styku fizycznego.\u003c\/li\u003e\n\u003cli\u003eZachowaj odpowiednie odstępy i mechaniczne wyrównanie podczas wsuwania bloku terminalowego 81544-01 na tylne złącza szafy, aby zapobiec uszkodzeniu pinów lub przerwom w obwodzie na magistrali 3300.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ techniczne i zakupowe\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy moduł terminalowy 81544-01 zawiera styki przekaźników mechanicznych do sterowania lokalnymi elektromagnesami wyzwalającymi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Nie, 81544-01 jest modułem bez przekaźników; przesyła surowe sygnały z przetworników i rejestratora, polegając na magistrali 3300 do przekazywania stanów alarmowych do dedykowanego modułu przekaźnikowego.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy ten komponent może być używany z dowolnym standardowym monitorem sondy zbliżeniowej serii 3300, na przykład modułem drgań promieniowych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Nie, ten numer części jest przypisany bezpośrednio do parametrów sprzętowych podwójnego monitora różnicowej rozszerzalności 3300\/45 i nie może być zastąpiony w innych gniazdach monitorujących.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jaka jest techniczna funkcja alternatywnego numeru części 78462-02 wymienionego na zespole?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Numer 78462-02 oznacza surową płytkę lub podzespół używany podczas produkcji, który odpowiada identycznie kompletnemu numerowi części najwyższego poziomu 81544-01.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860306795,"sku":"81544-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81544-01-xducr-i-o-and-record-terminals-phquym4p1wm_e2995e0f-7667-420e-acd8-3471ac8b1dcc.jpg?v=1765449280"},{"product_id":"bently-nevada-133827-01-3500-60-rtd-tc-non-isolated-i-o-module","title":"Moduł Wejścia\/Wyjścia Nieizolowany Bently Nevada 133827-01 3500\/60 RTD\/TC","description":"\u003ch3\u003eKluczowe informacje o produkcie\u003c\/h3\u003e\n\u003cp\u003eBently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(133827-01) pełni funkcję modułu I\/O RTD\/TC Non-Isolated \u003cstrong\u003e3500\/60\u003c\/strong\u003e o wysokiej niezawodności, zaprojektowanego do zewnętrznych zakończeń. Moduł ten łączy się bezpośrednio z zewnętrznymi blokami zaciskowymi, aby przetwarzać krytyczne sygnały temperatury z detektorów temperatury rezystancyjnej (RTD) i termopar (TC). W ciężkich gałęziach przemysłu, takich jak rafinacja petrochemiczna, przetwarzanie LNG i wytwarzanie energii, anomalie termiczne wskazują na nadchodzącą awarię maszyn. Dostarczając ciągły, wysokoprecyzyjny monitoring termiczny do systemu ochrony maszyn \u003cstrong\u003e3500\u003c\/strong\u003e, ten komponent zapobiega katastrofalnym awariom, eliminuje fałszywe wyłączenia i znacząco redukuje nieplanowane przestoje przemysłowe.\u003c\/p\u003e\n\u003ch3\u003eArchitektura sprzętowa i opcje interfejsu\u003c\/h3\u003e\n\u003cp\u003eSprzęt \u003cstrong\u003e133827-01\u003c\/strong\u003e został zaprojektowany do wysokiej gęstości przetwarzania sygnałów w szynie tylnej szafy \u003cstrong\u003e3500\u003c\/strong\u003e. Stanowi fizyczne połączenie między czujnikami temperatury zamontowanymi w terenie a główną kartą monitorującą \u003cstrong\u003e3500\/60\u003c\/strong\u003e. Architektura zewnętrznych zakończeń pozwala inżynierom na prowadzenie okablowania terenowego do oddzielnego bloku zaciskowego umieszczonego poza główną obudową szafy. To rozwiązanie upraszcza okablowanie o wysokiej gęstości w szafie, ułatwia szybkie prace konserwacyjne i poprawia zarządzanie kablami. Projekt obwodu bez izolacji opiera się na prawidłowym uziemieniu systemowym i zewnętrznym wysokiej jakości ekranowaniu, aby utrzymać integralność sygnału na długich odcinkach przewodów czujników przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eKluczowe parametry danych\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\u003c\/strong\u003e Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuł I\/O RTD\/TC Non-Isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStyl zakończenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZewnętrzne zakończenia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e244 mm x 23 mm x 112 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 do +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 do +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 W typowo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eObsługiwane wejścia czujników\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatynowe RTD, Miedziane RTD, Niklowe RTD, termopary typów E\/J\/K\/T\/S\/R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJak moduł 133827-01 radzi sobie z zakłóceniami sygnału, biorąc pod uwagę jego projekt bez izolacji?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł opiera się na wysokiej jakości zewnętrznym ekranowanym kablu skrętkowym oraz jednokrotnym uziemieniu przemysłowym. Inżynierowie muszą zapewnić prawidłowe zakończenie ekranu na zewnętrznym bloku, aby zminimalizować zakłócenia szumów wspólnego trybu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest główna zaleta wyboru zewnętrznych zakończeń zamiast wewnętrznych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZewnętrzne zakończenia pozwalają personelowi konserwacyjnemu na wymianę modułu I\/O bez odłączania okablowania terenowego. To rozwiązanie znacznie ogranicza błędy ludzkie podczas procedur wymiany w terenie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł może jednocześnie obsługiwać wejścia RTD i termopar na tej samej karcie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak. Oprogramowanie monitorujące \u003cstrong\u003e3500\/60\u003c\/strong\u003e umożliwia niezależną konfigurację kanałów. Można zaprogramować wybrane kanały dla RTD, a inne dla termopar na tym samym interfejsie \u003cstrong\u003e133827-01\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik instalacji w terenie i inżynierii okablowania\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtokoły ekranowania:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUziemiaj wszystkie ekrany przewodów czujników wyłącznie na zewnętrznym bloku zakończeniowym. Nie uziemiać ekranu po stronie czujnika w terenie. Zapobiega to niebezpiecznym pętlom uziemienia, które mogłyby zakłócać mikrovoltowe sygnały termopar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMoment dokręcania:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrzy mocowaniu modułu I\/O do tylnych szyn obudowy \u003cstrong\u003e3500\u003c\/strong\u003e dokręć śruby mocujące dokładnie momentem \u003cstrong\u003e0,5 N m\u003c\/strong\u003e, aby zapobiec naprężeniom złącza szyny tylnej.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWytyczne dotyczące prowadzenia termicznego:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUpewnij się, że kable zewnętrznych zakończeń są prowadzone z dala od linii wysokiego napięcia silników prądu przemiennego lub falowników (VFD), aby chronić obwód bez izolacji przed zakłóceniami elektromagnetycznymi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861289835,"sku":"133827-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133827-01-pc-board-plc-add-on-board-taordovzb0n_6f56e6e5-a692-4318-9449-b1d0067d7924.jpg?v=1765449309"},{"product_id":"bently-nevada-135489-04-3500-40m-proximitor-i-o-module-with-internal-barriers","title":"Moduł wejścia\/wyjścia Bently Nevada 135489-04 3500\/40M Proximitor z barierami wewnętrznymi","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e135489-04\u003c\/strong\u003e (135489-04) to wysokowydajny moduł wejścia\/wyjścia specjalnie zaprojektowany dla systemu monitorującego Bently Nevada \u003cstrong\u003e3500\/40M\u003c\/strong\u003e Proximitor. Ten czterokanałowy interfejs łączy przetworniki polowe z szafą ochrony maszyn, oferując zintegrowane \u003cstrong\u003ebarierki wewnętrzne\u003c\/strong\u003e i \u003cstrong\u003ezakończenia wewnętrzne\u003c\/strong\u003e. Ta konfiguracja jest kluczowa dla instalacji w strefach zagrożonych, ponieważ wbudowane bariery bezpieczeństwa ograniczają energię elektryczną, zapobiegając zapłonowi w atmosferach wybuchowych.\u003c\/p\u003e\n\u003cp\u003eModuł przetwarza sygnały impulsowe i przemieszczenia z przetworników zbliżeniowych, aby monitorować istotne parametry maszyn, w tym drgania promieniowe, pozycję osiową, ekscentryczność, rozszerzalność różnicową oraz REBAM. Dostarczając ciągłą ochronę maszyn i wysokiej jakości dane dla personelu operacyjnego, \u003cstrong\u003e135489-04\u003c\/strong\u003e stanowi kluczowy element w redukcji nieplanowanych przestojów krytycznych urządzeń w energetyce, przemyśle naftowym i petrochemicznym.\u003c\/p\u003e\n\u003ch3\u003eArchitektura sprzętowa i przetwarzanie sygnału\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e moduł zaprojektowano z architekturą o wysokiej gęstości, która obsługuje do czterech sygnałów z przetworników zbliżeniowych jednocześnie. Posiada wewnętrzną izolację galwaniczną oraz elementy bezpieczeństwa zgodne z parametrami jednostkowymi CSA-NRTL\/C i ATEX\/IECEx.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramowanie kanałów\u003c\/strong\u003e: Kanały monitorujące są programowane parami, co pozwala systemowi wykonywać jednocześnie do dwóch różnych funkcji (np. kanały 1 i 2 monitorują drgania promieniowe, a kanały 3 i 4 pozycję osiową).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBariery bezpieczeństwa\u003c\/strong\u003e: Moduł zawiera obwód bariery Proximitor z określonymi parametrami mocy (PWR) i sygnału (SIG), zapewniając, że poziomy Vmax i Imax pozostają w bezpiecznych granicach dla bezpieczeństwa wewnętrznego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzetwarzanie sygnału\u003c\/strong\u003e: Sprzęt oferuje zaawansowane możliwości filtrowania, w tym filtry bezpośrednie (do 4000 Hz), filtry szczelinowe oraz filtry stałej Q do śledzenia wektorów 1X i 2X.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e135489-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeria 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Proximitor z barierami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSygnały wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 4 przetworników zbliżeniowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo 7,7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZasilanie przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do +65 st. C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJak bariera wewnętrzna wpływa na wymagania dotyczące okablowania w terenie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e zawiera wbudowane bariery bezpieczeństwa, co eliminuje potrzebę stosowania zewnętrznych barier zenera lub izolatorów galwanicznych między szafą a strefą zagrożenia. Upraszcza to układ szafy i zmniejsza całkowitą impedancję pętli.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł może być używany zarówno do drgań promieniowych, jak i do położenia osiowego?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak. Monitor 3500\/40M w połączeniu z tym modułem I\/O pozwala na konfigurowanie kanałów parami do różnych funkcji, takich jak drgania promieniowe na jednej parze i pozycja osiowa na drugiej.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie są podstawowe parametry jednostkowe dla barier wewnętrznych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDla bariery Proximitor (PWR) Vmax wynosi 26,25 V, a Imax 110,48 mA. Dla sygnału (SIG) Vmax to 13,65 V, a Imax 2,74 mA.\u003c\/p\u003e\n\u003ch3\u003e🛠️ Przewodnik instalacji i kluczowe kroki\u003c\/h3\u003e\n\u003cp\u003eModel 135489-04 to moduł I\/O z \u003cspan\u003ewewnętrznymi barierami\u003c\/span\u003e i \u003cspan\u003ewewnętrznymi zakończeniami\u003c\/span\u003e. Montuje się go z tyłu szafy 3500, bezpośrednio za \u003cspan\u003emonitor Proximitor 3500\/40M\u003c\/span\u003e. Zapewnia iskrobezpieczną (IS) izolację dla przetworników znajdujących się w strefach zagrożenia.\u003c\/p\u003e\n\u003ch4\u003e1. Instalacja sprzętu\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eTryb obejścia kanałów:\u003c\/span\u003e Przed włożeniem modułu ustaw powiązane kanały monitorujące w tryb \u003cspan\u003eobejścia\u003c\/span\u003e, aby zapobiec przypadkowym wyłączeniom maszyn.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eWyrównanie slotów:\u003c\/span\u003e Włóż moduł I\/O do pełnowysokiego slotu z tyłu szafy, który odpowiada dokładnie modułowi monitorującemu 3500\/40M z przodu.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eMontaż i zabezpieczenie:\u003c\/span\u003e Wprowadź moduł wzdłuż szyn podwozia, aż połączy się solidnie z złączami tylnej płyty. Dokładnie dokręć dwa śruby motylkowe na przednim panelu.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eUziemienie IS:\u003c\/span\u003e Szafa 3500 \u003cspan\u003emusi zawierać moduł uziemienia 3500\/04 IS\u003c\/span\u003e. Upewnij się, że palce uziemiające z tyłu modułu I\/O mają pewny kontakt z magistralą uziemienia IS szafy.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Okablowanie i separacja fizyczna\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eKolorowe zaciski:\u003c\/span\u003e Podłącz okablowanie przetworników strefy zagrożenia do zacisków \u003cspan\u003eniebieskich\u003c\/span\u003e. Podłącz sygnały wyjściowe strefy bezpiecznej do zacisków \u003cspan\u003ezielonych\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eOdległość 50 mm (2 cale):\u003c\/span\u003e Zachowaj minimalną odległość fizyczną \u003cspan\u003e50 mm (2 cale)\u003c\/span\u003e między okablowaniem strefy zagrożenia (iskrobezpiecznym) a okablowaniem strefy bezpiecznej.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eŚcieżka prowadzenia przewodów:\u003c\/span\u003e Prowadź okablowanie strefy zagrożenia w górę do górnych korytek kablowych, a okablowanie strefy bezpiecznej w dół do dolnych korytek, aby zapobiec krzyżowaniu sygnałów.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e🛒 Uwagi dotyczące zamówień\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eBrak przetworników magistralnych:\u003c\/strong\u003e Moduły I\/O z wewnętrznymi barierami \u003cspan\u003enie obsługują\u003c\/span\u003e przetworników magistralnych (wspólne linie zasilania). Każdy przetwornik musi być okablowany niezależnie.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWymagania dotyczące głębokości obudowy: \u003c\/strong\u003eModuły z wewnętrznymi barierami są głębsze niż standardowe moduły I\/O. \u003cspan\u003eNie mieszczą się w standardowych szafach o głębokości 400 mm\u003c\/span\u003e. Wymagana jest minimalna głębokość szafy \u003cspan\u003e600 mm\u003c\/span\u003e lub obudowa montowana na przepustach\/panelu.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRedukcja liczby slotów:\u003c\/strong\u003e Instalacja obowiązkowego modułu uziemienia 3500\/04 IS zajmuje jeden dedykowany slot I\/O. Zmniejsza to maksymalną liczbę dostępnych slotów monitorujących w standardowej szafie 19-calowej \u003cspan\u003ez 14 do 13\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eTylko zakończenia wewnętrzne: \u003c\/strong\u003eTen konkretny model (-04) posiada wewnętrzne zaciski śrubowe. \u003cspan\u003eNie może być używany\u003c\/span\u003e z zewnętrznymi blokami zakończeniowymi (ETB) ani z prefabrykowanymi kablami.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOgraniczenia temperaturowe: \u003c\/strong\u003eSzafy wyposażone w wewnętrzne bariery mają węższy zakres temperatur pracy od \u003cspan\u003e0°C do +65°C\u003c\/span\u003e (32°F do +150°F), w porównaniu do standardowego dolnego limitu -30°C. Zapewnij odpowiednią wentylację szafy.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863583595,"sku":"135489-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-04-i-o-module-with-internal-barriers-and-internal-terminations-pfud1qtzn2t_898c93e6-a81e-4c17-af39-a2ae95a5f4a2.jpg?v=1765449377"},{"product_id":"bently-nevada-3500-20-02-01-00-135031-01-rack-interface-i-o-module","title":"Moduł interfejsu Rack I\/O Bently Nevada 3500\/20-02-01-00 135031-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/20-02-01-00 135031-01\u003c\/strong\u003e to specjalistyczny komponent interfejsu tylnego, który pełni funkcję kluczowego centrum wejścia\/wyjścia dla \u003cstrong\u003eSystemu Ochrony Maszyn Serii 3500\u003c\/strong\u003e. To połączenie sprzętowe łączy strukturę modułu interfejsu szafy \u003cstrong\u003e3500\/20\u003c\/strong\u003e (RIM) z płytą interfejsu tylnego \u003cstrong\u003e135031-01\u003c\/strong\u003e, zawierającą podwójne porty komunikacji szeregowej RS422\/RS485 oraz dedykowany port konfiguracyjny RS232. Zestaw przetwarza własne protokoły konfiguracyjne i dane statusu maszyn, umożliwiając bezpośrednie połączenie między szafami monitorującymi, narzędziami oprogramowania konfiguracyjnego oraz sieciami sterowania zakładu. Poza cyfrową komunikacją szeregową sprzęt integruje wbudowane \u003cstrong\u003estyki systemowe\u003c\/strong\u003e, w tym specjalistyczne linie sprzętowe do zdalnego resetowania szafy oraz dedykowaną konfigurację \u003cstrong\u003eprzekaźnika Not-OK\u003c\/strong\u003e, która przesyła sygnały awarii systemu bezpośrednio do systemów automatyki nadzorczej, nie przerywając krytycznej ścieżki monitorowania ochrony maszyn.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKompletny zintegrowany zestaw komunikacyjny łączący \u003cstrong\u003e3500\/20-02-01-00\u003c\/strong\u003e konfiguracja zamówienia oraz \u003cstrong\u003e135031-01\u003c\/strong\u003e Płyta interfejsu szeregowego.\u003c\/li\u003e\n\u003cli\u003ePodwójne niezależne porty szeregowe konfigurowalne do protokołów komunikacyjnych RS422 lub RS485 za pomocą wyboru sprzętowego na płycie tylnej.\u003c\/li\u003e\n\u003cli\u003eDedykowane złącza RS232 na panelu przednim i płycie tylnej zoptymalizowane do diagnostyki w terenie i narzędzi konfiguracyjnych szafy.\u003c\/li\u003e\n\u003cli\u003eWbudowane dedykowane sprzętowe \u003cstrong\u003estyki systemowe\u003c\/strong\u003e obsługujące zdalne polecenia resetu szafy oraz zewnętrzne mechanizmy blokady konfiguracji.\u003c\/li\u003e\n\u003cli\u003eZintegrowany \u003cstrong\u003eprzekaźnik Not-OK\u003c\/strong\u003e zapewniający automatyczne rozłączenie sprzętowe w przypadku wykrycia awarii w dowolnym kanale monitoringu.\u003c\/li\u003e\n\u003cli\u003eArchitektura komunikacji niezakłócająca, zapewniająca, że odpytywanie danych i konfiguracje nie wpływają na podstawową ścieżkę ochrony maszyn.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSzeregowa komunikacja Modbus lub własna łącząca szafy monitorujące drgania z przemysłowymi sterownikami PLC i Rozproszonymi Systemami Sterowania (\u003cstrong\u003eDCS\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eZdalne śledzenie zasobów maszyn zakładowych i scentralizowane zarządzanie konfiguracją wielu szaf.\u003c\/li\u003e\n\u003cli\u003eIntegracja sprzętowych ostrzeżeń o awariach szafy z pętlami blokad bezpieczeństwa za pomocą przekaźników styków systemowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod zamówienia \/ Numer części\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/20-AXX-BXX-CXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKompletny matrycowy moduł interfejsu szafy do zamówienia.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł interfejsu szafy z wewnętrznymi terminacjami RS422\/RS485.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja komunikacji: Komunikacja szeregowa RS232\/RS422\/RS485.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: Brak.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e135031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eKomponent płyty I\/O:\u003c\/strong\u003e Moduł I\/O interfejsu szafy z wewnętrznymi zakończeniami RS422\/RS485.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125744-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eGłówny komponent:\u003c\/strong\u003e Moduł interfejsu szafy (karta przednia).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKategoria parametrów\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePołączone oznaczenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/20-02-01-00 135031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O interfejsu szafy z komunikacją szeregową\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo 4,3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKomunikacja szeregowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS422 i RS485 (protokoły wybierane przełącznikiem)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfejs konfiguracyjny\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProtokół RS232 przez złącza D-sub z 9 pinami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStyk przekaźnika Not-OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A przy 24 V DC lub 120 V AC, konstrukcja SPDT z uszczelnieniem epoksydowym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWejściowe styczniki systemowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReset szafy, Blokada konfiguracji i Mnożnik wyzwolenia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary karty głównej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary karty I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg (2,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,45 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cp\u003eInterfejsy zaciskowe i wskaźniki wizualne na \u003cstrong\u003e3500\/20-02-01-00 135031-01\u003c\/strong\u003e układ zapewnia specyficzne sygnalizacje i śledzenie połączeń:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePort \/ Blok zaciskowy\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja \/ Przypisanie\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWskaźnik na panelu przednim; świeci na zielono, gdy interfejs przetwarza zadania oprogramowania bez wewnętrznej usterki.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWskaźnik na panelu przednim; miga, aby pokazać aktywną transmisję danych cyfrowych przez magistralę tylnego panelu.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort CONFIG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzedni port RS232 z 9 pinami dedykowany do podłączenia komputera polowego z oprogramowaniem konfiguracyjnym.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort HOST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTył \u003cstrong\u003e135031-01\u003c\/strong\u003e Połączenie RS232 z 9 pinami wykorzystywane do interfejsów odpytywania danych hosta.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSZAFKA RS422 \/ RS485\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWewnętrzne bloki śrubowe zakończenia do trasowania długodystansowych sieci szeregowych do pomieszczenia sterowania zakładu.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSTYCZNIKI SYSTEMOWE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzypisanie pinów tylnego bloku zaciskowego dla linii Reset szafy, Blokady konfiguracji oraz wyjść przekaźnika Not-OK.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział gniazda:\u003c\/strong\u003e Zamontuj kartę przednią towarzyszącą wyłącznie w Gnieździe 1 ramy szafy, które znajduje się bezpośrednio obok zatoki zasilacza, i przymocuj moduł interfejsu \u003cstrong\u003e135031-01\u003c\/strong\u003e do odpowiadającej pozycji gniazda tylnego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWybór protokołu:\u003c\/strong\u003e Ustaw wewnętrzne przełączniki zakończenia sprzętowego na karcie obwodu \u003cstrong\u003e135031-01\u003c\/strong\u003e, aby odpowiednio dopasować parametry sieci transmisji zrównoważonej RS422 lub RS485 w zakładzie.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminacja sieci:\u003c\/strong\u003e W przypadku instalacji końcowych na długiej magistrali szeregowej z wieloma odbiornikami włącz rezystory terminujące na pokładzie, aby zapobiec odbiciom sygnału i utracie danych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOkablowanie zabezpieczeń:\u003c\/strong\u003e Podłącz fizyczny zewnętrzny przełącznik kluczykowy do styków blokady konfiguracji na tylnym bloku zaciskowym, aby chronić konfigurację szafy przed nieautoryzowanymi lub przypadkowymi zmianami oprogramowania.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtokół uziemienia:\u003c\/strong\u003e Upewnij się, że ekrany kabli danych szeregowych są solidnie uziemione do bloku uziemienia obudowy, aby zapobiec zakłóceniom elektromagnetycznym zniekształcającym szybkie transmisje danych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e Dyrektywa Wspólnoty Europejskiej 2014\/30\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy EMC:\u003c\/strong\u003e EN 61000-6-2 (odporność przemysłowa), EN 61000-6-4 (emisje przemysłowe).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Dyrektywa niskonapięciowa 2014\/35\/UE, norma EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa RoHS:\u003c\/strong\u003e Zgodność europejska 2011\/65\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty Ameryki Północnej:\u003c\/strong\u003e cNRTLus Klasa I, Podział 2, Grupy A, B, C i D (T4 @ Ta = -20°C do +65°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty ATEX\/IECEx:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest funkcjonalny związek między kodem 3500\/20-02-01-00 a numerem części 135031-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/20-02-01-00\u003c\/strong\u003e reprezentuje dokładną wielocyfrową strukturę zamówienia fabrycznego, która wymaga komunikacji szeregowej i określonych wewnętrznych układów zacisków, podczas gdy \u003cstrong\u003e135031-01\u003c\/strong\u003e jest to dokładny numer części producenta przypisany do fizycznej tylnej płytki I\/O dostarczonej w tym zestawie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak przełączyć opcje sieci portu szeregowego z tyłu między protokołami RS422 i RS485?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWybór między protokołami wymaga dostosowania fizycznego położenia mikroprzełączników sprzętowych znajdujących się bezpośrednio na \u003cstrong\u003e135031-01\u003c\/strong\u003e montaż tylnej karty przed włączeniem urządzenia.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy całkowita awaria tego modułu interfejsu przerwie pętle zabezpieczeń maszyn?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, moduł działa poza główną, bezpośrednią ścieżką monitorowania sprzętowego, co oznacza, że całkowita utrata komunikacji lub zasilania tego modułu nie ma żadnego wpływu na podstawowe pętle wyłączników zabezpieczeń ani na wykonanie monitoringu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo się stanie, jeśli wystąpi awaria modułu gdziekolwiek w obudowie szafy 3500?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZintegrowana pętla styku przekaźnika Not-OK umieszczona na module tylnej płyty natychmiast zmienia stan przełącznika sprzętowego, zapewniając natychmiastowe, twardo okablowane ostrzeżenie systemowe do zewnętrznego sterownika PLC lub panelu alarmowego.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864075115,"sku":"135031-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-20-02-01-00-135031-01-rack-interface-i-o-module-jytao5rpj3n_3f8ea88d-edeb-4043-ac6e-7df04fa03052.jpg?v=1765449387"},{"product_id":"bently-nevada-3500-33-03-00-149992-03-low-current-16-channel-relay-output-module","title":"Moduł wyjściowy przekaźnikowy niskoprądowy 16-kanałowy Bently Nevada 3500\/33-03-00 149992-03","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003eBently Nevada 3500\/33-03-00 149992-03\u003c\/strong\u003e to pełnowymiarowy 16-kanałowy moduł wyjściowy przekaźnika zaprojektowany do zaawansowanego programowalnego głosowania bezpieczeństwa i logiki sterowania alarmem dla \u003cstrong\u003eSystemu Ochrony Maszyn Serii 3500\u003c\/strong\u003e. Jako fabrycznie skonfigurowany zespół niskoprądowy, \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e posiada specjalistyczne pozłacane styki przekaźników, zaprojektowane specjalnie, aby zapewnić maksymalną integralność styków i zapobiegać utlenianiu powierzchni w aplikacjach sygnalizacji niskoprądowej. Każde z jego szesnastu niezależnych wyjść posiada dedykowaną \u003cstrong\u003eLogikę Sterowania Alarmem\u003c\/strong\u003e, pozwalając operatorom na programowanie złożonych bramek logicznych AND\/OR wykorzystujących statusy alertu, zagrożenia lub Not-OK zbierane z dowolnego modułu monitorującego drgania, pozycję lub temperaturę w całej szafie. To połączenie sprzętu i oprogramowania służy jako wysoce niezawodny, sprzętowo głosowany most awaryjnego wyłączenia między krytycznymi obrotowymi zasobami zakładu a zewnętrznymi systemami sterowania rozproszonego (\u003cstrong\u003eDCS\u003c\/strong\u003e), programowalnymi sterownikami logicznymi (\u003cstrong\u003ePLC\u003c\/strong\u003e) lub systemami awaryjnego wyłączenia (\u003cstrong\u003eESD\u003c\/strong\u003e).\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKompletny zintegrowany 16-kanałowy zespół przekaźników bezpieczeństwa składający się z \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e kod systemu oraz \u003cstrong\u003e149992-03\u003c\/strong\u003e płyta główna procesora ze stykami złoconymi.\u003c\/li\u003e\n\u003cli\u003eWbudowane pozłacane styki zoptymalizowane do bardzo stabilnego przełączania obwodów niskonapięciowych i niskoprądowych.\u003c\/li\u003e\n\u003cli\u003eWysoce elastyczna macierz \u003cstrong\u003eLogiki Sterowania Alarmem\u003c\/strong\u003e wspierająca niestandardowe schematy głosowania oparte na wielokanałowych zmiennych alertu i zagrożenia.\u003c\/li\u003e\n\u003cli\u003eArchitektura hot-plug umożliwiająca wymianę karty na gorąco bez zakłócania pracy sąsiednich pętli ochrony maszyn online.\u003c\/li\u003e\n\u003cli\u003eIndywidualne przypisania przełączników sprzętowych na płytce drukowanej umożliwiające niezależną konfigurację Normalnie Załączony (\u003cstrong\u003eNE\u003c\/strong\u003e) lub Normalnie Wyłączony (\u003cstrong\u003eNDE\u003c\/strong\u003e) dla każdego przekaźnika.\u003c\/li\u003e\n\u003cli\u003ePrzejrzysta diagnostyka LED na przednim panelu zapewniająca wizualną ocenę stanu modułu w czasie rzeczywistym (OK), aktywności magistrali komunikacyjnej (TX\/RX) oraz stanów alarmowych poszczególnych kanałów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfejsy łączące alarmy niskoprądowe z ochroną ciężkich maszyn obrotowych do przemysłowych sterowników PLC i kontrolerów bezpieczeństwa.\u003c\/li\u003e\n\u003cli\u003eRozproszona logika głosowania i automatyczne mapowanie awaryjnego wyłączenia dla wysoko krytycznych turbin parowych, turbin gazowych i sprężarek.\u003c\/li\u003e\n\u003cli\u003eWielopunktowe sygnalizowanie awaryjnego wyłączenia w wymagających zakładach petrochemicznych, rafineriach ropy naftowej i elektrowniach.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod zamówienia \/ Numer części komponentu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKompletny zespół modułu przekaźnikowego 16-kanałowego z przekaźnikami niskoprądowymi, bez zatwierdzeń agencji.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja modułu przekaźnikowego niskoprądowego (używa modułu wyjściowego z pozłacanymi stykami).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: Brak.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eKomponent płyty głównej:\u003c\/strong\u003e Moduł główny przekaźnika 16-kanałowego niskoprądowego z pozłacanymi stykami.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKategoria parametru\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePołączone oznaczenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł przekaźnikowy 16-kanałowy (wariant niskoprądowy z pozłacanymi stykami)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 5,8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp styków przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzełącznik jednobiegunowy, dwutorowy (SPDT) \/ styki pozłacane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 V, 1 mA minimalnie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalne obciążenie styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V DC przy 2 A rezystancyjnie \/ 48 V DC przy 0,2 A rezystancyjnie \/ 125 V DC przy 0,1 A rezystancyjnie \/ 250 V AC przy 2 A rezystancyjnie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTryb pracy styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzełącznik na płycie wybierający Normalnie Bez Zasilania (NDE) lub Normalnie Zasilany (NE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary karty głównej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary karty I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,82 kg (1,8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,41 kg (0,9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cp\u003eOdczyty diagnostyczne na przednim panelu oraz fizyczne zakończenia z tyłu ułatwiają wyraźne śledzenie interfejsów:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIdentyfikator komponentu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis funkcjonalny \/ Przypisanie\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLampka stanu na przednim panelu; świeci ciągłym zielonym światłem, gdy wewnętrzne algorytmy oprogramowania działają prawidłowo.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLampka komunikacji na przednim panelu; szybko miga, wskazując aktywny ruch cyfrowej szyny.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda CHALRM (1 - 16)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLampki stanu kanału; niezależne diody LED świecą bezpośrednio, gdy dany kanał przekaźnika jest aktywowany.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStyki tylnego bloku zaciskowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiny połączeniowe tylnej szyny I\/O grupujące linie Wspólne (COM), Normalnie Otwarte (NO) i Normalnie Zamknięte (NC).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrzełączniki trybu przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFizyczne wielopozycyjne przełączniki dwutorowe na płycie przypisujące indywidualne stany kanałów do NDE lub NE.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePozycjonowanie w szafie:\u003c\/strong\u003e Wsuń kompletny zespół modułu \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e do dowolnego dostępnego slotu pełnej wysokości, znajdującego się ściśle po prawej stronie modułu Transient Data Interface (\u003cstrong\u003eTDI\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUstawienie tylne:\u003c\/strong\u003e Zamocuj odpowiedni 16-kanałowy wewnętrzny moduł zakończenia wejścia\/wyjścia (np. 149986-01) w pasującym tylnym slocie bezpośrednio za główną kartą.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja przełączników na płycie:\u003c\/strong\u003e Dostosuj wewnętrzne przełączniki fizyczne, aby określić wymagany stan Normalnie Załączony lub Normalnie Wyłączony dla każdego kanału przed wsunięciem płyty do aktywnego gniazda.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeryfikacja napięcia pętli:\u003c\/strong\u003e Potwierdź, że pętle instrumentów po stronie odbiorczej ściśle spełniają ograniczenia niskiego napięcia i niskiego prądu; wprowadzenie ciężkich obciążeń indukcyjnych lub wysokoprądowych zniszczy złocone powierzchnie styków.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja logiki:\u003c\/strong\u003e Otwórz oprogramowanie systemowe szafy, aby zmapować i załadować zamierzoną macierz głosowania AND\/OR do nieulotnej pamięci modułu przed testowaniem systemu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e Dyrektywa Wspólnoty Europejskiej 2014\/30\/UE (dyrektywa EMC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy EMC:\u003c\/strong\u003e EN 61000-6-2 (odporność przemysłowa), EN 61000-6-4 (emisje przemysłowe).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Dyrektywa niskonapięciowa 2014\/35\/UE, norma EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa RoHS:\u003c\/strong\u003e Zgodność europejska 2011\/65\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty do stref zagrożonych:\u003c\/strong\u003e cNRTLus Klasa I, Strefa 2: AEx\/Ex nA nC ic IIC T4 Gc \/ Klasa I, Podział 2, Grupy A, B, C i D (T4 @ Ta = -20°C do +65°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty ATEX\/IECEx:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest funkcjonalna zależność między kodem 3500\/33-03-00 a numerem części 149992-03?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e reprezentuje kompletny fabryczny numer modelu zamówienia określający 16-kanałowy system przekaźnikowy skonfigurowany do zastosowań niskoprądowych, podczas gdy \u003cstrong\u003e149992-03\u003c\/strong\u003e dokładny numer części producenta jest nadrukowany na fizycznej płycie głównego procesora niskoprądowego zawartej w tej konkretnej kombinacji.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDlaczego złocenie jest istotne dla styków w tym module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZłocenie jest kluczowe dla obwodów niskoprądowych (do 1 V, 1 mA), ponieważ standardowe srebrne styki z czasem tworzą warstwy utleniania na powierzchni przy niskich obciążeniach elektrycznych, podczas gdy złoto jest odporne na matowienie, zapewniając czystą ścieżkę połączenia.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy mogę wykonać wymianę na gorąco tego modułu podczas aktywnego monitorowania maszyn?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, jednostka posiada w pełni wymienną na gorąco architekturę, co pozwala zespołom serwisowym na wyjęcie lub włożenie karty do gniazda bez odłączania zasilania lub powodowania spadków sygnału na sąsiednich kanałach monitora.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy pojedyncze zamówienie tego produktu obejmuje zarówno przedni procesor, jak i tylną płytę terminalową?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKupując jako kompletny zapasowy lub nadmiarowy zespół zgodny z tymi specyfikacjami fabrycznymi, zazwyczaj oznacza to główną kartę; upewnij się, czy panel Twojego systemu wymaga również pasującego tylnego wewnętrznego bloku zakończeniowego 149986-01.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865549675,"sku":"3500\/33-03-00 149992-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-03-00-149992-03-spare-16-channel-low-current-relay-output-module-mybdn1u1yaf_20bc0d4c-1b25-4073-ac9e-559a8b4766c0.jpg?v=1765449433"},{"product_id":"bently-nevada-3500-61-01-01-133835-02-temperature-monitor-isolated-i-o-module","title":"Moduł izolowanego wejścia\/wyjścia do monitorowania temperatury Bently Nevada 3500\/61-01-01 133835-02","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eBently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e133835-02\u003c\/strong\u003e) to wysokowydajny moduł monitorowania temperatury z izolowanym wejściem\/wyjściem (I\/O) z wewnętrznymi zakończeniami. Zaprojektowany dla\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem ochrony maszyn, ten moduł zapewnia ciągłe monitorowanie zmiennych temperatury maszyn, chroniąc krytyczne zasoby, takie jak turbiny, sprężarki i duże pompy przed uszkodzeniami termicznymi.\u003c\/p\u003e\n\u003cp\u003eTa specyficzna izolowana konfiguracja została zaprojektowana, aby wyeliminować zakłócenia pętli masy, zapewniając niezawodny przepływ danych i zapobiegając fałszywym alarmom w wymagających środowiskach, takich jak rafinerie petrochemiczne i elektrownie. \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esłuży jako specyficzny komponent sprzętowy dla izolowanego I\/O z wewnętrznymi rezystorami zakończeniowymi, umożliwiając bezpośredni odczyt termopar do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epłyta tylna.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacje\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e (\u003cstrong\u003e133835-02\u003c\/strong\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIzolowany moduł I\/O termopary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypy sygnałów wejściowych\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIzolowane termopary (typ E, J, K, T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStyl zakończenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWewnętrzne zakończenia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaksymalnie 7,0 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKlasa izolacji\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 VDC izolacji galwanicznej\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 do 65 st. C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 103,1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cp\u003eDokładna identyfikacja sufiksu modelu jest wymagana, aby zapewnić zgodność z certyfikatami do stref zagrożenia oraz kompatybilność sprzętu.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e: Moduł serii monitorowania temperatury.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Izolowany moduł I\/O termopary z wewnętrznymi zakończeniami.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Zatwierdzenie agencji (CN, ATEX i IECEx dla strefy 2 oraz klasy I, dywizji 2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumer części sprzętowej\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePrzewodnik inżynieryjny i instalacyjny\u003c\/h3\u003e\n\u003ch3\u003eKroki instalacji\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspekcja sprzętu\u003c\/strong\u003e: Sprawdź piny modułu pod kątem uszkodzeń i zweryfikuj, czy ustawienia zworki na karcie monitora odpowiadają zamierzonemu typowi czujnika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstalacja modułu I\/O (tył)\u003c\/strong\u003e: Wyrównaj \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e z tylnymi prowadnicami podwozia w docelowej szczelinie. Mocno osadź moduł w płycie tylnej i zabezpiecz śruby motylkowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontaż modułu monitorującego (z przodu)\u003c\/strong\u003e: Włóż kartę monitorującą\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edo przedniego gniazda bezpośrednio naprzeciwko modułu I\/O. Zamocuj śrubami panelu przedniego.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOkablowanie polowe\u003c\/strong\u003e: Podłącz przewody czujników bezpośrednio do bloków zaciskowych\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. W przypadku termopar (TC) upewnij się co do prawidłowej polaryzacji przewodów dodatnich i ujemnych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKonfiguracja\u003c\/strong\u003e: Użyj oprogramowania\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfiguration przez port TDI, aby zdefiniować typy czujników i ustawić progi Alarmu\/Zagrożenia przed pobraniem do szyny.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eUwagi techniczne\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWewnętrzne zakończenia\u003c\/strong\u003e: Konstrukcja pozwala na bezpośrednie podłączenie okablowania polowego do modułu I\/O, eliminując potrzebę zewnętrznych bloków zaciskowych i zmniejszając wymagania dotyczące przestrzeni w szafie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOchrona przed awarią czujnika\u003c\/strong\u003e: Moduł posiada wbudowane wykrywanie przerw w przewodach. Awaria czujnika powoduje status „Nie OK”, informując DCS i zapobiegając przypadkowym wyłączeniom maszyny.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOgraniczenia wejścia\u003c\/strong\u003e: Ta konkretna konfiguracja (\u003cstrong\u003e-01\u003c\/strong\u003e) jest przeznaczona do izolowanych wejść termopar. Nie można mieszać sygnałów RTD i termopar na tym samym bloku I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJakie certyfikaty zapewnia opcja zatwierdzenia -01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePosiada certyfikaty ATEX, IECEx oraz CN do użytku w strefie 2 i w środowiskach niebezpiecznych klasy I, dywizji 2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł wymaga zewnętrznych rezystorów do zakończenia?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, ten\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSprzęt zawiera wewnętrzne rezystory zakończeniowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJak osiągana jest izolacja?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł zapewnia galwaniczną izolację 500 VDC, chroniąc integralność sygnału przed zakłóceniami pętli masy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865779051,"sku":"3500\/61-01-01 133835-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-01-01-133835-02-rtd-tc-non-isolated-with-internal-terminations-otr0qowkozy_008e3679-5f87-4675-9c12-e49f7807f590.jpg?v=1765449441"},{"product_id":"bently-nevada-82926-01-3300-transducer-input-output-and-recorder-terminal-module","title":"Bently Nevada 82926-01 3300 Transducer Input\/Output and Recorder Terminal Module","description":"\u003cp\u003eThe \u003cstrong\u003e82926-01\u003c\/strong\u003e Transducer Input\/Output and Recorder Terminal Module is a rear-mounting backplane interface engineered for the Bently Nevada 3300\/20 Dual Thrust Position Monitor. This module supports two independent channels of continuous shaft axial position monitoring, processing raw DC gap voltage signals derived from proximity probe transducers to detect deviation relative to calibrated machine clearances. By establishing direct signal routing to the 3300 chassis bus, the hardware enables early warning of thrust bearing failure based on the position of the thrust collar relative to the axial bearing babbitt. The control logic of the associated monitor evaluates these dual-channel inputs against programmable alert and danger setpoints, providing isolated recorder terminal outputs for trend tracking and interfacing with emergency shutdown systems without on-board electro-mechanical relays.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82926-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/20 Dual Thrust Position Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShaft axial position \/ Thrust displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Input Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity probe transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo on-board relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.27 kg (5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module translates the transducer gap voltage into precise axial displacement metrics, measuring how far the shaft has shifted from its calibrated electrical zero point.\u003c\/li\u003e\n\u003cli\u003eTo achieve proper rotor dynamics representation, the external proximity probes must be installed to observe the thrust collar directly rather than an arbitrary shaft shoulder.\u003c\/li\u003e\n\u003cli\u003eBecause the 82926-01 does not include mechanical relays, any active automatic machinery trip functions must be executed via backplane communication to a dedicated 3300 series relay module.\u003c\/li\u003e\n\u003cli\u003eDisconnecting or miswiring the terminal block outputs will register as a transducer fault or an out-of-limit gap voltage error on the front display of the 3300\/20 monitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement dedicated shield grounding protocols at the rear terminal strip by landing the proximity probe extension cable shield at the chassis ground terminal and isolating it at the sensor case.\u003c\/li\u003e\n\u003cli\u003eMaintain strict separation between low-voltage transducer input lines and high-voltage AC utility or control wiring to minimize electromagnetic noise injection into the thrust position loop.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminal lug screws are securely torqued during commissioning to prevent drift in the 4-20 mA recorder loops or intermittent sensor faults caused by mechanical vibration.\u003c\/li\u003e\n\u003cli\u003eAlign the module pins perfectly with the 3300 rack backplane before inserting to avoid bending contacts or disrupting cyclic data exchange with adjacent modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 82926-01 terminal module feature integrated mechanical relays for machinery interlocks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 82926-01 is a passive transducer input\/output and recorder terminal module that passes signal states to the 3300 backplane, requiring a separate relay module for physical contact execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this terminal module be used to interface with radial vibration or casing velocity monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this specific part number is designed and mapped exclusively to match the electrical and channel parameters of the 3300\/20 Dual Thrust Position Monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the recorder terminals on this rear module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The recorder terminals provide dedicated, continuous analog outputs proportional to the measured shaft axial position, allowing for direct connection to external DCS or chart recorders.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866499947,"sku":"82926-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-82926-01-i-o-and-record-terminals-relay-module-5onmhshp13c_f9312740-5fab-45b3-a3b6-9cfa1c7c35b5.jpg?v=1765449471"},{"product_id":"bently-nevada-146031-02-3500-22m-100base-fx-fiber-optic-i-o-module","title":"Moduł Wejścia\/Wyjścia Bently Nevada 146031-02 | 3500\/22M 100Base-FX (światłowodowy)","description":"\u003cp\u003eModuł \u003cstrong\u003e146031-02\u003c\/strong\u003e pełni rolę podstawowego tylnego interfejsu dla \u003cstrong\u003e3500\/22M Transient Data Interface (TDI)\u003c\/strong\u003e. Podczas gdy przedni moduł wykonuje złożone przetwarzanie sygnałów, ten komponent I\/O ustanawia warstwę fizyczną do komunikacji sieciowej i sygnalizacji sprzętowej.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e146031-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtokół komunikacji\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet 10Base-T \/ 100Base-TX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePort interfejsu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 (ekranowany)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKompatybilność z hostem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/22M TDI (np. 288055-01)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWyjście przekaźnikowe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedykowany przekaźnik \"OK\" (SPDT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMiejsce montażu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTylny slot obudowy (bezpośrednio za TDI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard okablowania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCat5e \/ Cat6 STP (ekranowana skrętka)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eZalety inżynieryjne\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStrumieniowanie danych o wysokiej przepustowości:\u003c\/strong\u003e Interfejs 100Base-TX umożliwia płynne przesyłanie danych o wysokiej rozdzielczości do oprogramowania \u003cstrong\u003eSystem 1\u003c\/strong\u003e. Zapobiega to zatorom danych podczas krytycznych zdarzeń przejściowych (uruchomienia\/wyłączenia).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUlepszona izolacja elektryczna:\u003c\/strong\u003e Wariant -02 zawiera zaawansowaną ochronę obwodów w porównaniu do starszych wersji, chroniąc szafę 3500 przed zakłóceniami wspólnego trybu i przepięciami typowymi dla przemysłowych pętli uziemienia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministyczny monitoring stanu systemu:\u003c\/strong\u003e Zintegrowany \u003cstrong\u003eprzekaźnik OK\u003c\/strong\u003e zapewnia twarde sprzęgło z Rozproszonym Systemem Sterowania (DCS). Natychmiast sygnalizuje awarię sprzętu TDI, gwarantując, że operatorzy nigdy nie polegają na uszkodzonych danych monitoringu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptymalna odporność na EMI:\u003c\/strong\u003e Dzięki zastosowaniu ekranowanych złączy RJ45 moduł utrzymuje integralność sygnału nawet przy instalacji blisko wysokoprądowych falowników o zmiennej częstotliwości (VFD).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eNajczęściej zadawane pytania\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy 146031-02 obsługuje starsze procesory przednie 3500\/22M?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO:\u003c\/strong\u003e Tak. Ten moduł jest w pełni kompatybilny wstecz z legacy 3500\/22M TDI (np. 138607-01). Jednak optymalizuje wydajność dla nowszej serii 288055-01, wykorzystując nowoczesne standardy Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jak zweryfikować status \"Nowy\" tego modułu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO:\u003c\/strong\u003e Każda jednostka dostarczana jest w oryginalnym fabrycznie zamkniętym opakowaniu antystatycznym. Numer seryjny na PCB odpowiada etykiecie Bently Nevada na opakowaniu, a styki przekaźnika \"OK\" nie wykazują cykli pracy. Na życzenie dostarczamy Certyfikat Zgodności (CoC) potwierdzający autentyczność.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jakie są kluczowe kroki instalacji 146031-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO:\u003c\/strong\u003e Moduł należy zamontować z tyłu szafy 3500, bezpośrednio za slotem zajmowanym przez 3500\/22M TDI. Należy używać ekranowanego okablowania skrętkowego (STP); brak uziemienia ekranu Ethernet przez port RJ45 może wprowadzać zakłócenia do próbek danych przejściowych.\u003c\/p\u003e\n\u003ch3\u003eKompatybilność i wysyłka\u003c\/h3\u003e\n\u003ch4\u003eWymagania systemowe\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModuł przedni:\u003c\/strong\u003e Wymaga Bently Nevada 3500\/22M TDI (288055-01 lub 138607-01).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOprogramowanie:\u003c\/strong\u003e W pełni kompatybilne z \u003cstrong\u003eSystem 1\u003c\/strong\u003e do monitorowania stanu oraz \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOkablowanie:\u003c\/strong\u003e Używaj standardowego kabla Cat5e lub Cat6 STP do danych; do zacisków przekaźnika OK stosuj przewody o przekroju 18 AWG do 22 AWG.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWysyłka i stan\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStan:\u003c\/strong\u003e 100% nowy, oryginalny fabryczny zapas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpakowanie:\u003c\/strong\u003e Oryginalne pudełko Bently Nevada z wewnętrzną ochroną ESD.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogistyka globalna:\u003c\/strong\u003e Oferujemy ekspresową wysyłkę międzynarodową przez DHL, FedEx i UPS. Na życzenie stosujemy pakowanie próżniowe na długie transporty morskie, aby zapobiec utlenianiu w wilgotnym środowisku.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867548523,"sku":"146031-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-146031-02-transient-data-interface-module-vxatwz05g2c_9c8ca786-0bbb-4941-8e3a-06aecca2c14c.jpg?v=1765449506"},{"product_id":"bently-nevada-135489-01-3500-42m-i-o-module-with-internal-barriers","title":"Moduł Wejścia\/Wyjścia Bently Nevada 135489-01 3500\/42M z Wbudowanymi Barierami","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e135489-01\u003c\/strong\u003e to 4-kanałowy moduł Wejścia\/Wyjścia (I\/O) zaprojektowany do współpracy z \u003cstrong\u003e3500\/42M\u003c\/strong\u003e Proximitor Seismic Monitor w ramach systemu ochrony maszyn \u003cstrong\u003eserii 3500\u003c\/strong\u003e. Ten konkretny wariant sprzętowy wyposażony jest w \u003cstrong\u003ewewnętrzne bariery\u003c\/strong\u003e oraz \u003cstrong\u003ewewnętrzne zakończenia\u003c\/strong\u003e, zapewniając kompaktowy i bezpieczny interfejs dla przetworników umieszczonych w niebezpiecznych środowiskach przemysłowych.\u003c\/p\u003e\n\u003cp\u003eModuł przetwarza sygnały dla \u003cstrong\u003e4 x Prox\/Accel\u003c\/strong\u003e (przetworników zbliżeniowych lub akcelerometrów) na kanałach od 1 do 4. Dzięki integracji wewnętrznych barier bezpieczeństwa, \u003cstrong\u003e135489-01\u003c\/strong\u003e ogranicza energię elektryczną wysyłaną do czujników polowych, zapobiegając potencjalnemu zapłonowi w atmosferach wybuchowych, jednocześnie eliminując potrzebę stosowania zewnętrznego sprzętu barierowego. Jest to kluczowy element do monitorowania drgań, położenia i aktywności sejsmicznej w przypadku cennych obrotowych urządzeń, takich jak turbiny, sprężarki i silniki.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e135489-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi (zakończenia wewnętrzne)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeria 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKompatybilny moduł główny\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e3500\/42M\u003c\/strong\u003e Monitor sejsmiczny Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x Prox\/Accel (kanały 1-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C do +65°C (32°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cp\u003ePodczas zamawiania części zamiennych do \u003cstrong\u003e3500\/42M\u003c\/strong\u003e system, zweryfikuj konkretne opcje zamówienia, aby zapewnić zgodność modułu I\/O z wymaganiami zakończeń i barier szafy.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e: \u003cstrong\u003e135489-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpcja zamówienia AA\u003c\/strong\u003e: 04\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpis I\/O\u003c\/strong\u003e: Moduł I\/O z barierami wewnętrznymi, zakończeniami wewnętrznymi, 4 x Prox\/Accel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUwagi inżynieryjne i instalacyjne\u003c\/h3\u003e\n\u003ch3\u003eOkablowanie polowe i zakończenia wewnętrzne\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBezpośrednie połączenie\u003c\/strong\u003e: Moduł \u003cstrong\u003e135489-01\u003c\/strong\u003e wykorzystuje wewnętrzne zakończenia, co oznacza, że okablowanie z przetworników jest podłączane bezpośrednio do zacisków śrubowych na obudowie modułu, znajdujących się z tyłu szafy 3500.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBezpieczeństwo w strefach zagrożonych\u003c\/strong\u003e: Bariery wewnętrzne są zaprojektowane tak, aby zachować integralność obwodów iskrobezpiecznych (IS). Upewnij się, że zachowana jest segregacja okablowania między okablowaniem IS a okablowaniem nie-IS w szafie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eObsługa przetworników\u003c\/strong\u003e: Ten moduł jest specjalnie przeznaczony dla wejść \u003cstrong\u003eProximity\u003c\/strong\u003e i \u003cstrong\u003eAccelerometer\u003c\/strong\u003e. Potwierdź, że typ przetwornika w terenie odpowiada konfiguracji kanałów (Kanały 1-4), aby uniknąć błędów przetwarzania sygnału.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKroki instalacji\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParowanie z monitorem\u003c\/strong\u003e: Ten moduł I\/O musi być zainstalowany w tylnej zatoce szafy 3500 odpowiadającej przedniemu modułowi monitora \u003cstrong\u003e3500\/42M\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpecyfikacje momentu dokręcania\u003c\/strong\u003e: Upewnij się, że wszystkie śruby zaciskowe są prawidłowo dokręcone, aby utrzymać stabilne połączenie elektryczne, szczególnie w środowiskach narażonych na wibracje przemysłowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZgodność środowiskowa\u003c\/strong\u003e: Dla modułów używanych z barierami wewnętrznymi temperatura pracy musi być utrzymywana w zakresie od \u003cstrong\u003e0°C do +65°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł I\/O może być używany z przetwornikami Velomitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł \u003cstrong\u003e135489-01\u003c\/strong\u003e jest przeznaczony dla \u003cstrong\u003e4 x Prox\/Accel\u003c\/strong\u003e. Użycie z innymi typami przetworników może wymagać innej wersji modułu I\/O lub specyficznych ustawień konfiguracyjnych w monitorze \u003cstrong\u003e3500\/42M\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest zaleta wersji „Internal Barrier”?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIntegruje bariery bezpieczeństwa bezpośrednio w module I\/O, zmniejszając wymaganą przestrzeń fizyczną w szafie i upraszczając architekturę okablowania dla zastosowań w strefach zagrożonych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł jest wymienny na gorąco?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChociaż system 3500 obsługuje wymianę na gorąco, standardową praktyką inżynierską jest ominięcie wszelkich powiązanych wyłączeń maszyn przed wymianą modułu I\/O, aby zapobiec niezamierzonym zatrzymaniom.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869055851,"sku":"135489-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-01-i-o-module-4-channel-internal-barrier-akragbb2a4i_c5513e8d-df36-47f1-b473-bf9c4c7b9969.jpg?v=1765449560"},{"product_id":"bently-nevada-3500-42m-135489-02-proximitor-seismic-i-o-module","title":"Bently Nevada 3500\/42M 135489-02 Proximitor Seismic I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-144\"\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e135489-02\u003c\/strong\u003e\u003cspan class=\"citation-144\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 4-channel Proximitor Seismic I\/O Module with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eInternal Intrinsic Safety Barriers\u003c\/strong\u003e\u003cspan class=\"citation-144 citation-end-144\"\u003e\u003cspan\u003e \u003c\/span\u003eand Internal Terminations designed for the 3500 Series Machinery Protection System.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSeated in the rear slot of the 3500 instrumentation rack, this module serves as the direct hardware interface linking field-mounted sensors to the front-facing 3500\/42M Proximitor Seismic Monitor module.\u003c\/p\u003e\n\u003cp\u003eThe hardware architecture provides two dedicated proximity\/acceleration channels and two specialized Velomitor channels.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-143 citation-end-143\"\u003eEquipped with integrated Zener-type internal barriers, the 135489-02 restricts electrical fault energy traveling from the rack into the field, providing explosion-proof protection for transducers deployed in Class I, Division 1 or Zone 0 hazardous environments without the need for external galvanic isolation panels.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/42M (Rear Barrier Variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number \/ ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e135489-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor Seismic I\/O Module with Internal Barriers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Proximity\/Acceleration + 2 Velomitor channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Intrinsic Safety Barriers (Internal Zener Barriers)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Multi-position Screw Terminal Blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Transducers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximity Probes, Accelerometers, Velomitors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConditioned Values\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRadial Vibration, Thrust, Eccentricity, Velocity, Acceleration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.201 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eMachinery verification networks operating in hazardous processing environments require exact tracking of rear I\/O card variation codes. Procure components matching the factory keys below.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMain System Core Monitor Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/42M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Order Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e135489-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated Front Module Counterpart:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/42M Proximitor Seismic Processor Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Notes \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Wiring and Barrier Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-142 citation-end-142\"\u003eThe 135489-02 card houses integrated explosion protection circuitry.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eField wiring routing out from the module's terminal block must follow strict intrinsic safety segregation guidelines.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKeep all intrinsically safe field transducer cables physically separated from non-intrinsically safe wires by a minimum clearance boundary of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2.0 inches)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDividers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlternatively, install dedicated grounded metal dividers to avoid voltage arc induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Screw Terminal Allocation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField cabling maps directly onto the built-in internal termination blocks. Use high-quality 3-wire twisted-shielded instrumentation cables (18 AWG to 22 AWG copper) to carry low-voltage displacement and acceleration paths.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePreparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStrip individual conductor insulation jackets back exactly 7 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect outer grounding shields together and anchor them to the clean instrumentation earth rail at the structural cabinet bulkhead.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDo not\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eloop shield drain wires through the proximity signal common (COM) screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Handshake and Safety Restrictions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 135489-02 limits terminal fault currents through precision internal barriers, plugging non-designated transducer loads into the channel pins can overload the internal Zener elements, destroying the protection loop. Prior to activating sensor excitation power, match the channel selection parameters (e.g., standard proximity probe versus Velomitor configuration) within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto align with specific paired-channel hardware attributes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between the 135489-02 and standard 3500\/42M I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-141 citation-end-141\"\u003eA: The 135489-02 features built-in internal safety barriers.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStandard I\/O versions do not contain intrinsic insulation paths, requiring plants to source and mount independent, external barrier boards when routing sensor leads into classified hazardous plant fields.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the channel structure split into two distinct sensor pairs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The hardware layout dictates specialized input electronics. Channels 1 and 2 are balanced to process voltage variables from high-frequency proximity probes or accelerometers, while Channels 3 and 4 feature targeted current loops designed specifically for active Velomitor-type velocity sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I hot-swap this rear I\/O module while the 3500 rack is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the front-facing 3500\/42M card allows hot-swapping, extracting the rear 135489-02 while powered up breaks the physical sensor feedback loop and cuts excitation paths. This immediately triggers system interlocks and trips connected safety relays. Always change the rack security keyswitch to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emode and establish channel bypass blocks before initiating hardware service.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869612907,"sku":"135489-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-02-i-o-module-with-internal-barriers-and-internal-terminations-cfy5l5nmfwu_80b4d093-609f-4e33-a266-6b0411b744dd.jpg?v=1765449578"},{"product_id":"honeywell-experion-pks-fta-t-20-digital-output-relay-field-termination-assembly","title":"Honeywell Experion PKS FTA-T-20 Digital Output Relay Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Field Termination Assembly (FTA) within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager (SMS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystems. It serves as the physical and electrical interface between the system's digital output modules and the external field equipment.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-load or isolated switching requirements, the FTA-T-20 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 channels of relay-contact outputs\u003c\/strong\u003e. Each channel offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNO (Normally Open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNC (Normally Closed)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtacts, allowing for flexible fail-safe configurations. By utilizing interposing relays on the FTA, the system protects the sensitive controller electronics from field-side electrical surges and allows the switching of higher voltages and currents (up to 250 Vac or 110 Vdc) than a standard electronic output could handle.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FTA-T-20 is engineered for seamless integration into Honeywell safety and control racks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 independent relay channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSPDT (Single Pole Double Throw) configuration, providing both NO and NC terminals for every channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects to the controller I\/O module via a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem interconnection cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor direct connection of field cables, supporting a variety of wire gauges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard DIN-rail mounting for installation in I\/O cabinets or marshalling panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNFS (Non-Fail Safe) Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically used in applications where the safety logic is managed by the controller, and the relay acts as the final switching element.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Relay Contact)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Vac \/ 110 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNO \/ NC (Change-over)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterconnection Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIC-C-07\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminals (T-Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10209\/2\/1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of using an FTA-T (Screw Terminal) over an FTA-E (ELCO)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion is designed for direct field wiring where the cables are terminated individually at the assembly. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ELCO) version is typically used for \"marshalling-to-marshalling\" connections using pre-fabricated multi-core cables. The FTA-T-20 is ideal for cabinets where field sensors\/actuators are wired directly to the I\/O rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC loads on the same FTA-T-20?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the relay contacts are rated for both 250 Vac and 110 Vdc, it is standard engineering practice to keep load types consistent across an FTA to prevent noise and to simplify maintenance. However, since the 8 channels are galvanically isolated from each other, they can technically switch different voltage sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I replace a faulty relay on this FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDepending on the specific hardware revision, the relays on the FTA-T-20 are often socket-mounted. This allows for \"hot-maintenance\" where an individual relay can be replaced without replacing the entire termination assembly or disturbing the wiring of the other 7 channels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that wire ferrules are used when connecting to the screw terminals. This prevents wire fraying and ensures a gas-tight connection, which is critical in corrosive industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable should be routed away from high-power AC lines to prevent induced noise, even though the relay outputs are relatively robust.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor highly inductive loads (such as large solenoid valves or motor starters), it is recommended to install external RC snubbers (for AC) or flyback diodes (for DC) to extend the life of the FTA relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFusing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways ensure that field-side circuits are properly fused. The FTA-T-20 provides the switching logic, but the current-limiting protection should be handled by external terminal fuses or circuit breakers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667743338859,"sku":"FTA-T-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-20-fta-output-module-qqfm5mreu3l_e04138f4-fd7c-4a5d-9cc3-0b76caa2f4a1.jpg?v=1765501439"},{"product_id":"honeywell-fta-t-02-fail-safe-digital-output-fta-24-channel-24-48-60-vdc","title":"Honeywell FTA-T-02 Fail-Safe Digital Output FTA 24-Channel 24\/48\/60 VDC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eFTA-T-02 (FTA-T-02)\u003c\/span\u003e by \u003cspan\u003eHoneywell\u003c\/span\u003e is a high-integrity \u003cspan\u003eFail-safe Digital Output Field Termination Assembly (FTA)\u003c\/span\u003e engineered for seamless integration with Safety Manager and FSC systems. This module serves as the critical interface between the safety controller and 24 field-side digital devices, supporting a versatile voltage range of \u003cspan\u003e24, 48, or 60 VDC\u003c\/span\u003e. Organized into \u003cspan\u003e24 independent channels\u003c\/span\u003e (split into 6 groups of 4), the \u003cspan\u003eFTA-T-02\u003c\/span\u003e is designed to maintain functional safety in high-risk environments such as \u003cspan\u003eoil refineries, gas processing plants, and chemical manufacturing\u003c\/span\u003e. Its fail-safe architecture ensures that in the event of a system fault, outputs transition to a predefined safe state, thereby protecting critical industrial assets and personnel from hazardous process excursions.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Parameter Matrix\u003c\/h3\u003e\n\u003cp\u003eThe following table provides the rigorous technical data required for engineering specifications and procurement alignment, adhering to Google E-E-A-T technical depth standards.\u003c\/p\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eTechnical Parameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFail-safe Digital Output Field Termination Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Channels (6 groups of 4)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 \/ 48 \/ 60 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Continuous Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Voltage (IEC 1010)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 VDC (Category 3) \/ 150 VDC (Category 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 cm2 (AWG 14)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Nm (0.37 ft-lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRail Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN EN TS32 \/ TS35 x 7.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.5 cm x 7 cm x 5.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Safety Integration FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHow does the \"Fail-safe\" designation impact the operation of the FTA-T-02?\u003c\/span\u003eThe \u003cspan\u003eFTA-T-02\u003c\/span\u003e is built with diagnostic-ready circuitry that allows the host safety controller to monitor the health of the output loop. In the event of a detected internal failure or loss of communication, the module is designed to ensure the digital outputs revert to a \"de-energized\" or safe state, preventing unintended activation of field equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the significance of the 6-group channel architecture?\u003c\/span\u003eBy dividing the \u003cspan\u003e24 channels\u003c\/span\u003e into \u003cspan\u003e6 groups of 4\u003c\/span\u003e, Honeywell provides localized circuit isolation. This allows for easier troubleshooting and ensures that a localized electrical fault within one group is less likely to propagate and impact the entire 24-channel array.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan the FTA-T-02 handle higher voltages than 60 VDC?\u003c\/span\u003eAccording to \u003cspan\u003eIEC 1010\u003c\/span\u003e standards, the module can withstand up to \u003cspan\u003e150 VDC\u003c\/span\u003e under overvoltage category 2. However, for continuous, safe operation of the digital output logic, it is rated for nominal \u003cspan\u003e24\/48\/60 VDC\u003c\/span\u003e systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Deployment \u0026amp; Field Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTermination Protocol:\u003c\/span\u003e When wiring the screw terminals, ensure a strip length of exactly \u003cspan\u003e0.7 cm (0.28 in)\u003c\/span\u003e. Use a precision torque screwdriver to apply \u003cspan\u003e0.5 Nm\u003c\/span\u003e of force. Under-tightening can lead to resistive heating, while over-tightening may damage the AWG 14 lead or the terminal block housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRail Spacing and Heat Management:\u003c\/span\u003e The \u003cspan\u003eFTA-T-02\u003c\/span\u003e requires a used rail length of \u003cspan\u003e14.6 cm\u003c\/span\u003e. In high-density cabinets, allow for adequate vertical spacing between the FTA and adjacent modules to facilitate natural convection, as the 2 A per channel load can generate significant heat during concurrent activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGrounding for EMC Compliance:\u003c\/span\u003e To maintain the \u003cspan\u003eCE and UL\u003c\/span\u003e certification integrity, ensure the DIN rail is bonded to a low-impedance earth ground. This provides a clear path for electrical transients and protects the fail-safe logic from electromagnetic interference (EMI) originating from nearby power switching equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Resilience \u0026amp; Technical Superiority\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell FTA-T-02\u003c\/span\u003e stands as a benchmark for reliability in the Field Termination Assembly sector. Its robust physical construction (\u003cspan\u003e14.5 cm x 7 cm\u003c\/span\u003e) is optimized for the rigors of industrial control rooms where vibration and thermal fluctuations are constant variables. By utilizing high-quality screw terminals and gold-plated connector pins, the \u003cspan\u003eFTA-T-02\u003c\/span\u003e ensures long-term contact stability. As an \u003cspan\u003eOriginal and New\u003c\/span\u003e component, it offers full compatibility with legacy Safety Manager and FSC platforms, providing a high-availability solution for modernizing safety instrumented systems (SIS) without requiring extensive field-wiring re-engineering.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667751825771,"sku":"FTA-T-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-02-fail-safe-digital-output-module-afgq1sfwuk5_07e51c7d-5b35-4f5b-83e6-76cd00ca3f1b.jpg?v=1765501568"},{"product_id":"honeywell-900b16-0001-controledge-hc900-16-slot-i-o-chassis","title":"Honeywell 900B16-0001 ControlEdge HC900 16-Slot I\/O Chassis","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001 (900B16-0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity 16-slot I\/O rack designed for the Honeywell ControlEdge HC900 Process \u0026amp; Safety Controller system. This chassis serves as the physical and communication backbone for various HC900 I\/O modules, including analog inputs\/outputs and digital inputs\/outputs. Engineered for modularity and scalability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both standard process control and SIL 2 safety-related applications, providing a ruggedized mounting platform with integrated power distribution and backplane communications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge HC900 \/ Series 900\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Slots (for I\/O modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReserved Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated slots for Power Supply and Scanner\/CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistributed 5V and 24V from Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mount (Internal Cabinet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 2 Certified (when used with appropriate modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade aluminum\/steel hybrid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed internal bus for I\/O scanning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eStructural Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to maximize I\/O density within a single rack footprint. It facilitates the \"hot-swap\" capability of the HC900 system, allowing modules to be replaced while the rest of the rack remains powered and operational. The chassis includes integrated grounding points and terminal block connectors for the power supply, ensuring clean power delivery to sensitive analog instrumentation. It is a critical component for large-scale boiler control, thermal processing, and water treatment applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this chassis include the Power Supply or CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the empty 16-slot rack frame. The Power Supply (e.g., 900P01) and the CPU or Scanner module must be purchased and installed separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix safety and non-safety modules in this rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the HC900 architecture allows for the coexistence of non-safety and safety-critical I\/O within the same chassis, provided the system configuration adheres to the Honeywell Safety Manual guidelines.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667990147435,"sku":"900B16-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-900b16-0001-plc-module-s1z4in1e0wu_03d48335-7db6-4543-a6e4-e6c67c76b1f5.jpg?v=1765504887"},{"product_id":"honeywell-cc-pail51-experion-series-c-low-level-analog-input-module","title":"Honeywell CC-PAIL51 Experion Series-C Low Level Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-71\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-71\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-71\"\u003eCC-PAIL51 (CCPAIL51)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-71\"\u003e\u003cspan\u003e \u003c\/span\u003estands as a high-performance temperature sensing solution within the Honeywell Experion Series-C Mark II I\/O family\u003c\/span\u003e\u003cspan class=\"citation-71 citation-end-71\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-70\"\u003e\u003c\/span\u003eSpecifically engineered for mission-critical thermal monitoring in industries such as hydrocarbon processing and power generation, this Low Level Analog Input (LLAI) module provides high-density support for 16 RTD and Thermocouple (TC) circuits\u003cspan class=\"citation-70 citation-end-70\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-69\"\u003e\u003c\/span\u003eThe module’s core value lies in its high-integrity data qualification; it features a fixed 1-second PV scanning rate coupled with advanced Open Thermocouple Detection (OTD) protection\u003cspan class=\"citation-69 citation-end-69\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-68\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-68\"\u003eBy automatically setting Process Variables to \"Not a Number\" (NAN) upon sensor failure, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-68\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-68\"\u003e\u003cspan\u003e \u003c\/span\u003eprevents erratic control loop responses, effectively reducing plant risk and minimizing expensive unscheduled maintenance caused by instrument degradation\u003c\/span\u003e\u003cspan class=\"citation-68 citation-end-68\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-67\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-67\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-67\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-67\"\u003e\u003cspan\u003e \u003c\/span\u003ehardware is optimized for signal stability and thermal management within high-density cabinet environments\u003c\/span\u003e\u003cspan class=\"citation-67 citation-end-67\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-66\"\u003eComprehensive Sensor Library:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-66\"\u003e\u003cspan\u003e \u003c\/span\u003eNative linearization for a broad spectrum of sensors, including Platinum (100 ohm), Nickel (120 ohm), and Copper (10\/50 ohm) RTDs, as well as ANSI Type J, K, E, T, B, S, and R thermocouples\u003c\/span\u003e\u003cspan class=\"citation-66 citation-end-66\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-65\"\u003eTotal Galvanic Isolation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-65\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides robust 16-channel isolation, including channel-to-channel, channel-to-DCS backplane, and channel-to-power common, shielding sensitive measurements from ground loop interference\u003c\/span\u003e\u003cspan class=\"citation-65 citation-end-65\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1-second update cycle includes a mandatory OTD check before PV propagation.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-64\"\u003e\u003c\/span\u003eIf sensor resistance exceeds 1500 ohms, the system triggers a guaranteed trip to protect control integrity\u003cspan class=\"citation-64 citation-end-64\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-63\"\u003eSeries-C Mark II Innovation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-63\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes the \"tilted\" module design for superior heat dissipation and features a vertical mounting profile to streamline high-density field wiring entry\u003c\/span\u003e\u003cspan class=\"citation-63 citation-end-63\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eCC-PAIL51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eHoneywell Experion Series-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eLow Level Analog (Temperature) Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e16 (Fully Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e1 second (Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eIOTA Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e\n\u003ca href=\"https:\/\/www.plcprotech.com\/products\/dc-tail51-honeywell-series-c-analog-output-24v-iota-module\"\u003eDC-TAIL51\u003c\/a\u003e (Non-Redundant 9-inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eNominal Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e-20 to +100 mV (TC only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eGain Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e0.050% Full Scale Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e+\/- 20 ppm per deg C Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eCMRR (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e120 dB Minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eRTD Excitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e1 milliamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e0 to 60 deg C (Standard Series-C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the CC-PAIL51 prevent \"false\" control actions during a sensor break?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-62\"\u003e\u003c\/span\u003eThe module utilizes a \"sample and hold\" OTD cycle\u003cspan class=\"citation-62 citation-end-62\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-61\"\u003e\u003c\/span\u003eIf an open sensor is detected, the Process Variable is set to NAN (Not a Number) and a soft failure is reported\u003cspan class=\"citation-61 citation-end-61\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-60\"\u003e\u003c\/span\u003eThis ensures no invalid data is propagated to the controller, preventing inappropriate PID responses\u003cspan class=\"citation-60 citation-end-60\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the specific IOTA options for this module?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-59\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-59\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-59\"\u003e\u003cspan\u003e \u003c\/span\u003etypically resides on the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-59\"\u003eDC-TAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-59\"\u003e\u003cspan\u003e \u003c\/span\u003eIOTA, which is a 9-inch (228 mm) assembly for non-redundant applications\u003c\/span\u003e\u003cspan class=\"citation-59 citation-end-59\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support millivolt-only inputs without linearization?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-58\"\u003e\u003c\/span\u003eYes, the module supports standard millivolt types ranging from -20 to +100 millivolts, allowing it to interface with specialized non-standard sensing devices\u003cspan class=\"citation-58 citation-end-58\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-57\"\u003eCold Junction Compensation (CJC):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-57\"\u003e\u003cspan\u003e \u003c\/span\u003eAll thermocouple inputs are automatically compensated using a CJC device located on the IOTA\u003c\/span\u003e\u003cspan class=\"citation-57 citation-end-57\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. To ensure accuracy, avoid installing the IOTA near high-heat components that could create localized thermal gradients across the termination assembly. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-56\"\u003eRTD Wiring Integrity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-56\"\u003e\u003cspan\u003e \u003c\/span\u003eFor RTD sensors, lead resistance must be strictly managed (maximum 15 ohms)\u003c\/span\u003e\u003cspan class=\"citation-56 citation-end-56\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-55\"\u003e\u003c\/span\u003eUse high-quality shielded 3-wire or 4-wire cabling to maintain the 120 dB Common Mode Rejection Ratio (CMRR) and prevent noise from distorting low-level temperature signals\u003cspan class=\"citation-55 citation-end-55\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-54\"\u003eSurge Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-54\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module features integrated surge protection per EN 61000-4-5 (1 kV line-to-line, 2 kV line-to-ground)\u003c\/span\u003e\u003cspan class=\"citation-54 citation-end-54\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. For outdoor sensor runs or environments with high lightning risk, external primary surge arrestors are still recommended to protect the IOTA electronics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668023210347,"sku":"CC-PAIL51","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-pail51-low-level-analog-output-ffkuwq3reb5_d4e37d60-6deb-45a2-8082-bc85412bb644.jpg?v=1765505238"},{"product_id":"honeywell-experion-pks-8c-tdoda1-51307149-175-digital-output-iota","title":"Honeywell Experion PKS 8C-TDODA1 (51307149-175) Digital Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 32-channel Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform. This \"Single\" IOTA serves as the mounting base and field wiring interface for a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output module. It is engineered to drive 24 VDC discrete field devices such as solenoid valves, relays, and indicator lamps. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures the signature Series 8 vertical design, which significantly reduces the cabinet footprint while enhancing thermal management through natural convection. This specific version (51307149-175) is factory-treated with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e, providing a critical layer of protection against moisture and corrosive atmospheric elements commonly found in industrial processing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a ruggedized electrical interface for discrete control.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Accommodates 32 digital output channels, allowing for high-density wiring and simplified common-return routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix indicates compliance with ISA S71.04 Class G3, protecting the PCB and components from corrosive gases like Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Series 8 Form Factor\u003c\/strong\u003e: Fits onto a standard Series 8 carrier, facilitating an efficient \"chimney-effect\" airflow that keeps the electronic module cool.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Circuit Protection\u003c\/strong\u003e: Designed to work with the I\/O module’s diagnostic capabilities, including short-circuit protection and load monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Friendly Design\u003c\/strong\u003e: Allows for the electronic I\/O module to be replaced (\"hot-swapped\") without disconnecting the field wiring terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307149-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.60 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a redundant configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDODA1 is a \"Single\" IOTA, meaning it has only one slot for an I\/O module. For redundant DO applications where two modules back up each other, you must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eredundant IOTA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum current per channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module can drive typical 24 VDC solenoids, the total current capacity is limited. For high-current loads or high-frequency switching, it is highly recommended to use interposing relays to prevent thermal stress on the IOTA and module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the field power provided to the outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField excitation power (24 VDC) is usually supplied through the Series 8 carrier busbar. The IOTA then distributes this power to the individual channels based on the commands from the C300 controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Precautions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse ferrules on all field wiring to ensure reliable contact and prevent stray wire strands from shorting adjacent terminals in the high-density terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is firmly snapped into the carrier and that the carrier itself is properly bonded to the instrument ground bar. Inadequate grounding can lead to intermittent diagnostic errors and susceptibility to electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor the \"Blown Fuse\" diagnostics in the Experion software. If a fuse-protected circuit is used, identify and rectify the field-side short circuit before replacing the module or resetting the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Spacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the manufacturer-specified 150 mm clearance above and below the IOTA row to ensure adequate cooling. Overheating is a primary cause of shortened electronic lifespan in high-density DC cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668027765099,"sku":"8C-TDODA1 51307149-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdoda1-51307149-175-digital-output-bussed-irxllnpltok_da87522a-b045-4c95-88b5-ba132f5cec30.jpg?v=1765505296"},{"product_id":"honeywell-experion-pks-8c-paona1-51454469-175-analog-output-module","title":"Honeywell Experion PKS 8C-PAONA1 (51454469-175) Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 16-channel Analog Output (AO) module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O architecture. As a core component of the C300 control system, this module converts digital control algorithms into accurate 4-20 mA analog signals to drive final control elements such as valve positioners, variable speed drives, and dampers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically engineered for high-density deployments, featuring the Series 8 slim vertical form factor that enhances natural convection cooling. This \"175\" variant comes standard with a factory-applied G3 conformal coating, providing essential protection against corrosive atmospheric contaminants. By ensuring stable signal delivery in harsh industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplays a vital role in maintaining process stability and reducing the total cost of ownership through enhanced hardware durability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its ruggedized electronics and seamless integration with the Series 8 I\/O Link.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Supports up to 16 independent analog loops per module, maximizing I\/O density within the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-HART Signal Path\u003c\/strong\u003e: Dedicated to standard 4-20 mA analog modulation, offering a streamlined and cost-effective solution for control loops that do not require digital HART diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51454469-175 hardware revision is specifically treated to resist corrosion from H2S, Cl2, and ammonia, meeting ISA S71.04 Class G3 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Provides comprehensive electrical isolation between field wiring and the internal system bus, protecting the C300 controller from field transients and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Ready\u003c\/strong\u003e: Fully compatible with redundant Series 8 IOTAs, allowing for seamless bumpless transfer in high-availability control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAONA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51454469-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.8 Watts Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.20 x 9.80 x 4.20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an 8C-PAONA1 with an 8C-PAOHA1 (HART version)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 8C-PAOHA1 is generally backward compatible and can reside on the same IOTA. However, you must update the module configuration in the Experion Control Builder to enable the HART features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"Non-HART\" designation mean for my field devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt means this module only transmits the 4-20 mA analog signal. If you have \"Smart\" valve positioners, they will still move correctly based on the current, but the DCS will not be able to read digital diagnostic data or valve signatures from them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the G3 coating on this part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number suffix \"175\" is the primary indicator of the G3 conformal coating. Physically, the board will have a slight uniform sheen compared to non-coated \"100\" series boards when viewed under reflected light.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-PAONA1 is designed to drive loads up to a maximum of 600 Ohms. Before commissioning, calculate the total loop resistance including the field wire run and the positioner impedance. High-resistance loops can cause the output to saturate or trigger \"Output Open\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). In a redundant configuration, ensure the \"OK\" LED on the partner module is solid green before removing the module being serviced to prevent a process upset.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain signal integrity, use individual shielded twisted-pair cables for each AO channel. The shields must be terminated at the IOTA's ground bar to prevent electromagnetic interference from inducing \"jitter\" in the valve control signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031205739,"sku":"8C-PAONA1 51454469-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona1-51454469-175-analog-output-module-pr3lnm2gi33_9db50288-9e32-48b9-bb61-3adc7964f986.jpg?v=1765505321"},{"product_id":"honeywell-experion-pks-8c-tdila1-51307141-175-digital-input-iota","title":"Honeywell Experion PKS 8C-TDILA1 (51307141-175) Digital Input IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Input Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. This module acts as the physical and electrical foundation for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input module, providing 32 channels of discrete signal acquisition. It is designed to interface with field contacts such as push-buttons, limit switches, and motor starter auxiliary contacts. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered with the signature Series 8 vertical orientation to optimize cabinet space and enhance thermal management through natural convection. This specific variant, identified by part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51307141-175\u003c\/strong\u003e, features a factory-applied G3 conformal coating, making it resilient against corrosive gases and high-humidity environments typical in oil refineries and chemical processing plants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for high-speed signal processing and simplified field maintenance.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Provides terminal connections for up to 32 discrete inputs, sharing a common return to maximize wiring density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix ensures the board is treated to withstand harsh environmental conditions, protecting against corrosion from Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Form Factor\u003c\/strong\u003e: Mounts onto a Series 8 carrier, allowing for a \"slim\" I\/O profile that significantly reduces the overall footprint of the DCS cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Management\u003c\/strong\u003e: Distributes 24 VDC field excitation power to the input contacts while maintaining electrical isolation for the C300 controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance\u003c\/strong\u003e: The IOTA design allows for the replacement of the electronic I\/O module without disturbing the field wiring connected to the terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307141-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.65 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 11.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 8C-TDILA1 support redundant input module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDILA1 is a \"Single\" IOTA, meaning it supports only one 8C-PDILA1 module. For redundant applications where two modules monitor the same 32 field points, you must use the redundant version, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILB1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field excitation voltage does this IOTA provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis IOTA is designed for 24 VDC discrete inputs. The 24 VDC power is typically sourced from the system power supply through the Series 8 carrier bus and distributed to the field contacts via the IOTA terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a non-corrosive environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the G3 coating (51307141-175) is designed for harsh environments, it is fully compatible with standard control room environments. It provides an extra layer of protection against unexpected humidity or airborne contaminants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Organization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the 32-channel density, use fine-stranded wire with ferrules for all connections to the compression terminals. Clear labeling and organized wire ducting are essential to prevent cross-talk and facilitate future troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is properly snapped into the Series 8 carrier and that the carrier is bonded to the instrument earth bar. Proper grounding is critical for the internal surge protection circuitry to function correctly during field-side transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the recommended 150 mm clearance above and below the IOTA row. The vertical design relies on the \"chimney effect\" for cooling; obstructing airflow can lead to localized hotspots and premature failure of the inserted I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031304043,"sku":"8C-TDILA1 51307141-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdila1-51307141-175-input-module-hhpp2chb3tf_64736da3-58c9-4b6e-97d0-b96456e712d1.jpg?v=1765505322"},{"product_id":"honeywell-experion-pks-8c-paona2-analog-output-module-non-hart","title":"Honeywell Experion PKS 8C-PAONA2 Analog Output Module (Non-HART)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA2 (8CPAONA2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Analog Output (AO) module belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. Engineered for precision and mission-critical reliability, this 16-channel module converts digital control commands from the C300 controller into standard 4-20 mA analog signals. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily used to drive final control elements such as pneumatic valve positioners, variable speed drives (VSD), and dampers. As a \"Series 8\" component, it features a vertical, slimline design that optimizes cabinet density and promotes natural thermal convection. This specific variant is the \"Non-HART\" version, providing a cost-effective solution for control loops where digital field device diagnostics are not required, while maintaining the rugged G3-level environmental protection standard in Honeywell's premium I\/O line.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to integrate seamlessly into the Experion PKS architecture, focusing on signal stability and hardware longevity.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Density\u003c\/strong\u003e: Provides 16 independent analog output channels, allowing for high-density I\/O configurations in a small physical footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries 8 Architecture\u003c\/strong\u003e: Designed to be \"plug-and-play\" with Series 8 IOTAs (Input Output Termination Assemblies), supporting both non-redundant and redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The module is factory-treated with a conformal coating to protect internal circuitry against humidity and corrosive atmospheric contaminants (ISA S71.04 Class G3).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Features robust isolation between the I\/O Link (backplane) and the field-side electronics, preventing ground loops and protecting the C300 processor from field electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Loop Response\u003c\/strong\u003e: Optimized for low-latency signal delivery, ensuring that control valve movements are synchronized with the DCS PID logic for stable process modulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 254.719px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e8C-PAONA2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e12-bit Minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e5.5 Watts Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e15.00 x 10.00 x 4.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 8C-PAONA2 be used to communicate with HART-enabled valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 8C-PAONA2 can drive a HART-enabled valve positioner using a standard 4-20 mA signal, it\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecannot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eread or write digital HART data. For full HART pass-through and diagnostics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOHA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule must be used instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle a loss of communication with the controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-PAONA2 features a configurable \"Fail-Safe\" state. In the event of an I\/O Link failure or controller shutdown, each channel can be programmed to Hold Last Value (HLV) or go to a pre-defined safe value (e.g., 0 mA or 4 mA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with older Series A or Series C IOTAs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-PAONA2 is strictly a Series 8 module and must be mounted on a Series 8 IOTA, such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Single) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Redundant).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance Matching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the total loop resistance (including field wiring and the actuator\/positioner impedance) does not exceed the module's maximum drive capability, typically 600 Ohms at 24 VDC. Exceeding this limit will result in \"Output Low\" errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Procedure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). When replacing a module in a redundant pair, ensure the \"Secondary\" LED is stable before removing the \"Primary\" module to ensure a bumpless transfer of control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse twisted-pair shielded cable for all 16 channels. The shield should be grounded at the IOTA's grounding bar. Proper shielding is critical to prevent electromagnetic interference (EMI) from inducing \"jitter\" in the 4-20 mA output signal, which can lead to premature mechanical wear on valve positioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035236203,"sku":"8C-PAONA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona2-dcs-backplane-nkoilvcvcx2_ef231f8b-558f-431c-9001-1acf9869e5f7.jpg?v=1765505367"},{"product_id":"honeywell-experion-pks-8c-tdodb1-digital-output-redundant-iota","title":"Honeywell Experion PKS 8C-TDODB1 Digital Output Redundant IOTA","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eHoneywell 8C-TDODB1 (8CTDODB1)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis \"Redundant\" IOTA is a critical infrastructure component that allows two\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output modules to operate in a 1-out-of-2 (1oo2) configuration.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn this setup,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe primary and secondary modules work in tandem; if the primary module fails,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe secondary module takes over control of the field devices instantaneously without a \"bump\" in the process.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis primarily utilized in sectors requiring mission-critical safety and uptime,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as Emergency Shutdown (ESD) systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eturbine trip circuits,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand critical solenoid header controls in chemical and power plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to provide a robust physical and electrical foundation for redundant digital control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Module Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures two dedicated slots for Digital Output modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emanaging the synchronization and load-sharing logic between the two units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e32-Channel Density\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 32 individual digital output channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etypically used for driving 24 VDC solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erelays,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor indicator lamps.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eG3 Conformal Coating\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFactory-treated with a protective layer to ensure long-term reliability in environments with high humidity or corrosive gas concentrations (conforming to ISA G3 standards).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVertical I\/O Design\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes the Series 8 vertical mounting format,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich promotes natural airflow for cooling and reduces the overall footprint within the control cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Blown Fuse Detection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides circuit protection and diagnostic feedback to the C300 controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing operators to identify field-side wiring faults or short circuits immediately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODB1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Redundant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 12.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I use only one module on the 8C-TDODB1 IOTA?\u003c\/strong\u003e\u003cspan class=\"\"\u003eYes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 8C-TDODB1 is designed for redundancy,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit can operate with a single module.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe system will report a \"Redundancy Lost\" alarm until the second module is installed and synchronized.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the difference between 8C-TDODA1 and 8C-TDODB1?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe 8C-TDODA1 is a \"Single\" IOTA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting only one module with no hardware redundancy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis the \"Redundant\" version,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efeaturing two module slots for high-availability applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes this IOTA provide power to the field solenoids?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe IOTA distributes 24 VDC power from the cabinet busbar to the outputs.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe total current capacity is limited per channel.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor high-current solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003einterposing relays should be used to protect the IOTA circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Cable Installation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the redundancy link between the two modules is securely seated.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWithout this link,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe modules cannot synchronize their internal states,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eleading to independent operation and potential control conflicts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eField Wiring Termination:\u003c\/strong\u003e\u003cspan\u003e When wiring the 32 channels,\u003c\/span\u003e\u003cspan\u003e use ferrules to prevent stray wire strands from causing short circuits between adjacent terminals.\u003c\/span\u003e\u003cspan\u003e Given the high density of the 8C-TDODB1,\u003c\/span\u003e\u003cspan\u003e cable management and clear labeling are essential for future troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e\u003cspan\u003e The IOTA must be bonded to the instrument earth bar via the carrier's grounding system.\u003c\/span\u003e\u003cspan\u003e Proper grounding is vital for the correct operation of the blown-fuse detection circuitry and to prevent electromagnetic noise from affecting the I\/O Link communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035662187,"sku":"8C-TDODB1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdodb1-digital-output-module-nto0msgjdle_0be4d2d8-53a4-4ee4-9ea3-94936ec0e1b4.jpg?v=1765505373"},{"product_id":"honeywell-experion-pks-8c-taoxa1-51307135-175-analog-output-iota","title":"Honeywell Experion PKS 8C-TAOXA1 (51307135-175) Analog Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Analog Output Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. As a fundamental component of the C300 control environment, this IOTA provides the physical mounting base and field wiring interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output module. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to support 16 channels of 4-20 mA signals, commonly used to drive control valves, actuators, and speed governors in critical process industries such as oil and gas, power generation, and pharmaceutical manufacturing. Its vertical form factor is a signature of the Series 8 design, engineered to promote natural convection cooling and minimize the footprint within high-density control cabinets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for rapid installation and long-term signal integrity in demanding industrial settings.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Provides dedicated screw terminal points for 16 analog output loops, supporting both redundant and non-redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Mounting Profile\u003c\/strong\u003e: Specifically designed for the Series 8 Slim chassis, allowing for efficient cable management and superior thermal dissipation compared to traditional horizontal racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51307135-175 variant is factory-treated with a protective coating to withstand Class G3 harsh environments, preventing corrosion from H2S, Cl2, and other caustic gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Distribution\u003c\/strong\u003e: Manages the distribution of 24 VDC power from the cabinet bus to the inserted I\/O module and the field-side loop, ensuring consistent drive current across all 16 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Interface\u003c\/strong\u003e: Features robust, high-density compression terminals that facilitate secure connections for field cabling, with integrated support for shield grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TAOXA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307135-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (16-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAOXA1 \/ 8C-PAOYA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 10.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 8C-TAOXA1 compatible with HART communication modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the IOTA is a passive termination assembly, it is designed to transparently pass HART digital data when paired with an Analog Output module that supports HART (such as the 8C-PAOHA1).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 51307135-175 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 175 suffix specifically denotes the G3 conformal coating. Standard, non-coated versions carry different suffixes. This version is required for any installation where the control room atmosphere is not strictly regulated for corrosive contaminants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA for redundant AO module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-TAOXA1 is a non-redundant (Single) IOTA. For redundant applications where two modules back up one another on the same field wiring, you must use the redundant version of the IOTA (8C-TAOXB1).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Discipline\u003c\/strong\u003e: When connecting 4-20 mA loops to the 8C-TAOXA1, ensure that signal cables are kept separate from high-voltage AC lines. Use twisted-pair shielded cables and terminate the shield at the IOTA designated ground point to minimize electromagnetic interference (EMI) that can cause valve hunting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Before applying power, ensure the 8C-PAOXA1 module is fully seated onto the IOTA and the captive mounting screws are tightened. A loose module can cause intermittent Channel Fault or I\/O Link Failure alarms in the Experion System Status Display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAtmospheric Protection\u003c\/strong\u003e: Since this is the 51307135-175 G3-coated version, ensure that when field wiring is completed, the cabinet entries are sealed. The coating protects the board, but terminal connections remain vulnerable to heavy oxidation if the cabinet is left open in a corrosive environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668040085867,"sku":"8C-TAOXA1 51307135-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-taoxa1-51307135-175-analog-output-module-ee5lfji1kt3_bed50637-0f91-47a7-be5b-ee3622df234d.jpg?v=1765505433"},{"product_id":"bently-nevada-3500-60-133827-01-3500-series-rtd-tc-non-isolated-i-o-module-external-terminations","title":"Moduł wejścia\/wyjścia nieizolowany Bently Nevada 3500\/60 133827-01 serii 3500 RTD\/TC z zewnętrznymi zakończeniami","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojketowany do integracji w systemie ochrony maszyn 3500, \u003cstrong\u003e3500\/60 133827-01\u003c\/strong\u003e pełni funkcję specjalistycznego interfejsu wejścia\/wyjścia do monitorowania temperatury. Ten moduł jest skonfigurowany specjalnie jako nieizolowany moduł I\/O RTD\/TC zoptymalizowany pod kątem architektury zewnętrznych przyłączy (ET). Poprzez prowadzenie sygnałów polowych przez zewnętrzne bloki przyłączeniowe zapewnia gęsty, łatwy w utrzymaniu interfejs dla krytycznych wejść czujników temperatury maszyn.\u003c\/p\u003e\n\n\u003cp\u003eModuł \u003cstrong\u003e133827-01\u003c\/strong\u003e bezpośrednio łączy się z Detektorami Temperatury Rezystancyjnej (RTD) i Termoparami (TC) w celu monitorowania profili temperatury na wysokowartościowych maszynach przemysłowych. Fizyczny sprzęt przetwarza te surowe sygnały czujników i przesyła zdigitalizowane dane do głównego modułu monitorowania temperatury 3500\/60, umożliwiając ciągłą ochronę zasobów, generowanie stanów alarmowych oraz integrację logiki wyłączania maszyn.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAkceptuje bezpośrednie wejścia ze standardowych czujników Termopar (TC) i Detektorów Temperatury Rezystancyjnej (RTD).\u003c\/li\u003e\n  \u003cli\u003eNieizolowana architektura obwodu zaprojektowana w celu optymalizacji efektywności ścieżki przetwarzania sygnału.\u003c\/li\u003e\n  \u003cli\u003eObsługuje zewnętrzne bloki przyłączeniowe (ET), aby zminimalizować złożoność okablowania szafy i usprawnić konserwację w terenie.\u003c\/li\u003e\n  \u003cli\u003eW pełni kompatybilny ze standardowymi szynami i komponentami monitorującymi serii 3500.\u003c\/li\u003e\n  \u003cli\u003eProjekt sprzętu umożliwiający wymianę modułu na gorąco bez wyłączania całego systemu ochrony, zgodnie z procedurami bezpieczeństwa na miejscu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMonitorowanie temperatury łożysk i stojanów turbin parowych i gazowych przemysłowych.\u003c\/li\u003e\n  \u003cli\u003eDiagnostyka obudów sprężarek i pomp o dużej wydajności.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie temperatury uzwojeń dużych silników elektrycznych i generatorów.\u003c\/li\u003e\n  \u003cli\u003eKrytyczne pętle ochrony temperatury rur procesowych i wymienników ciepła.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eParametr\u003c\/th\u003e\n    \u003cth\u003eSpecyfikacja\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eNumer części\/model\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e3500\/60 133827-01\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eSeria systemu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eSystem ochrony maszyn serii 3500\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eModuł I\/O RTD\/TC nieizolowany\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eTyp przyłącza\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eZewnętrzne przyłącza (ET)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eWaga netto\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0,45 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eWaga wysyłkowa\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e3,00 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eInterfejs połączenia\u003c\/th\u003e\n    \u003cth\u003eOpis funkcjonalny\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eZłącze tylnej szyny\u003c\/td\u003e\n    \u003ctd\u003eWłasnościowy wielopinowy złącze tylnej szyny 3500 do szybkiej komunikacji cyfrowej i dystrybucji zasilania.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eZewnętrzny port terminala I\/O\u003c\/td\u003e\n    \u003ctd\u003eDedykowany port interfejsu zaprojektowany do podłączania kabli wielożyłowych prowadzących do zewnętrznego bloku przyłączeniowego.\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUpewnij się, że moduł jest zainstalowany w tylnym slocie I\/O bezpośrednio odpowiadającym przedniemu modułowi monitorowania temperatury 3500\/60.\u003c\/li\u003e\n  \u003cli\u003ePodczas prowadzenia kabli do zewnętrznego bloku przyłączeniowego zachowaj odpowiedni odstęp fizyczny od linii wysokiego napięcia, aby zapobiec zakłóceniom elektromagnetycznym.\u003c\/li\u003e\n  \u003cli\u003ePonieważ ten moduł wykorzystuje architekturę nieizolowaną, ścisłe przestrzeganie wymagań dotyczących uziemienia systemu na zewnętrznym bloku przyłączeniowym jest kluczowe, aby uniknąć błędów pętli masy.\u003c\/li\u003e\n  \u003cli\u003eZweryfikuj, czy całe okablowanie czujników odpowiada specyficznej konfiguracji RTD lub Termopary zaprogramowanej w oprogramowaniu konfiguracyjnym 3500\/60.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668278210923,"sku":"3500\/60 133827-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350060133827-01-aobwipssfrf_bebbdf72-46f5-4992-b1f2-0c48dbf4ce31.jpg?v=1765520323"},{"product_id":"bently-nevada-163179-03-3500-series-process-monitor-i-o-module","title":"Moduł Wejścia\/Wyjścia Monitor Procesu Serii 3500 Bently Nevada 163179-03","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojketowany do integracji z systemem ochrony maszyn 3500, \u003cstrong\u003e163179-03\u003c\/strong\u003e to specjalistyczny moduł wejścia\/wyjścia, który łączy się bezpośrednio z monitorem procesowym 3500\/62. Ta konkretna odmiana modułu jest wyposażona wewnętrzne bariery bezpieczeństwa i wewnętrzne zaciski, co pozwala na bezpośrednie podłączenie czujników i nadajników polowych znajdujących się w środowiskach niebezpiecznych bez konieczności stosowania dodatkowych zewnętrznych barier.\u003c\/p\u003e\n\n\u003cp\u003eModuł \u003cstrong\u003e163179-03\u003c\/strong\u003e Funkcjonuje poprzez odbiór przemysłowych sygnałów analogowych — takich jak 4 do 20 mA DC lub proporcjonalne napięcie — i przekierowywanie ich do głównego modułu monitora 3500\/62 w celu cyfryzacji, przetwarzania i porównania z nastawami alarmowymi. To rozwiązanie umożliwia ciągły nadzór kluczowych zmiennych procesowych, w tym ciśnienia, temperatury, poziomu, przepływu i stężeń gazów w krytycznych maszynach wirujących i systemach zakładu.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBezpośrednia kompatybilność z główną płytą monitora procesowego Bently Nevada 3500\/62.\u003c\/li\u003e\n  \u003cli\u003eZintegrowane wewnętrzne bariery bezpieczeństwa eliminują potrzebę stosowania zewnętrznego sprzętu ochrony przeciwwybuchowej.\u003c\/li\u003e\n  \u003cli\u003eWewnętrzne bloki zaciskowe zapewniają bezpieczne, trwałe połączenia okablowania polowego.\u003c\/li\u003e\n  \u003cli\u003eObsługuje 6 niezależnych kanałów wejść sygnałów zmiennych procesowych z nadajników.\u003c\/li\u003e\n  \u003cli\u003eSolidna konstrukcja zaprojektowana do środowisk automatyki przemysłowej o wysokiej niezawodności.\u003c\/li\u003e\n  \u003cli\u003eW pełni konfigurowalny za pomocą standardowego oprogramowania do konfiguracji szaf 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOchrona maszyn i monitorowanie stanu w przemyśle petrochemicznym oraz rafineriach ropy naftowej i gazu.\u003c\/li\u003e\n  \u003cli\u003eNadzór nad zmiennymi procesowymi turbin parowych, gazowych i wodnych w zakładach wytwarzania energii.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie przetwarzania w przemysłowej oczyszczalni ścieków.\u003c\/li\u003e\n  \u003cli\u003eCiągły monitoring ciśnienia, przepływu i poziomu w procesach produkcji chemicznej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części \/ model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e163179-03\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNazwa serii\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSystem ochrony maszyn serii 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKompatybilny moduł monitora\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMonitor procesowy 3500\/62\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp zakończenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWewnętrzne zakończenia\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKonfiguracja bariery\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWewnętrzne bariery bezpieczeństwa (iskrobezpieczne)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLiczba kanałów\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6 kanałów różnicowych lub pojedynczych\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFormaty sygnału wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 do 20 mA DC, +1 do +5 VDC (proporcjonalny)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95% bez kondensacji\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eGrupa połączeń zaciskowych\u003c\/th\u003e\n      \u003cth\u003eOpis funkcji\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eKanały 1 do 6\u003c\/td\u003e\n      \u003ctd\u003eTerminale wejściowe nadajnika procesowego (Sygnał, Wspólny, Ekran)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWewnętrzne uziemienie bariery\u003c\/td\u003e\n      \u003ctd\u003eDedykowane połączenie odniesienia uziemienia iskrobezpiecznego\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eWyłącz zasilanie szafy 3500 przed instalacją lub demontażem modułu I\/O 163179-03, aby zapobiec awariom systemu lub uszkodzeniom sprzętu.\u003c\/li\u003e\n  \u003cli\u003eWłóż moduł do wyznaczonego gniazda na tylnej ściance szafy, bezpośrednio za odpowiadającą kartą monitora 3500\/62.\u003c\/li\u003e\n  \u003cli\u003eUpewnij się, że połączenie uziemienia obudowy oraz wewnętrznej bariery bezpieczeństwa jest podłączone do solidnego, niskoomowego uziemienia.\u003c\/li\u003e\n  \u003cli\u003ePrzestrzegaj określonych wytycznych dotyczących momentu dokręcania śrub zaciskowych, aby zapobiec poluzowaniu połączeń przewodów w warunkach drgań.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eZgodność z CE\u003c\/li\u003e\n  \u003cli\u003eUL\/CSA Klasa I, Podział 2 \/ Podział 1 (przy instalacji z odpowiednimi barierami)\u003c\/li\u003e\n  \u003cli\u003eATEX \/ IECEx Bezpieczne iskrobezpieczne do stref 0\/1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668298133867,"sku":"163179-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/163179-03-brp2zhgahwh_48c65830-ef12-4137-9446-6349e064224d.jpg?v=1765520471"},{"product_id":"bently-nevada-172103-01-3500-65-rtd-isolated-tip-tc-i-o-module","title":"Moduł wejścia\/wyjścia Bently Nevada 172103-01 3500\/65 RTD\/izolowany czujnik termoparowy typu I","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e172103-01\u003c\/strong\u003e to 16-kanałowy moduł wejścia\/wyjścia (I\/O) monitorujący temperaturę, zaprojektowany dla szafy systemu ochrony maszyn 3500\/65. Zapewnia fizyczne interfejsy połączeniowe dla detektorów temperatury rezystancyjnej (RTD) oraz izolowanych termopar typu tip (TC). Moduł posiada wewnętrzne zakończenia, umożliwiające podłączenie okablowania czujników temperatury bezpośrednio do bloku terminalowego z tyłu szafy 3500, bez konieczności stosowania zewnętrznych bloków zakończeniowych.\u003c\/p\u003e\n\u003cp\u003eTen moduł I\/O łączy się bezpośrednio z modułem monitora 3500\/65, aby przetwarzać ciągle próbkowane dane temperatury. Jest głównie wykorzystywany w krytycznych zastosowaniach maszyn, w tym łożysk turbin parowych i gazowych, dużych uzwojeń stojana silników, linii wydechowych sprężarek oraz monitorowania obudów pomp przemysłowych. Moduł obsługuje zarówno ciągłą weryfikację alarmów, jak i integrację logiki wyłączania maszyn w połączeniu z modułami przekaźnikowymi systemu 3500.\u003c\/p\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eNumer części:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e172103-01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eProducent:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eKompatybilność monitora:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMonitor temperatury 3500\/65 z 16 kanałami\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eTyp zakończenia:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWewnętrzne zakończenia (zawiera wtyczkę terminalową 20-pinową, numer części 173005)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eGrupa funkcjonalna:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCzęści zamienne do systemów ochrony maszyn\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable class=\"NRefec\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"cZCYO firstRow\"\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eParametr\u003c\/th\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eSpecyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e172103-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eMarka\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eTyp produktu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eModuł monitorowania temperatury I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eSeria\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eSeria 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eKanały wejściowe\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e16 niezależnych kanałów (RTD lub izolowany termopara typu tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eImpedancja wejściowa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003e 1 MΩ na wszystkich wejściach przetworników\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003ePrąd wzbudzenia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e913 μA ± 7 μA stałego prądu na kanał RTD (przy 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eRozdzielczość\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e1°C lub 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eDokładność pomiaru\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e± 3°C (± 5,4°F) przy +25°C otoczenia (zawiera wewnętrzną kompensację zimnego złącza)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eZużycie energii\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eMaksymalnie 3,0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eWymiary (W x S x G)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eWaga\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0,45 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eTemperatura pracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eTemperatura przechowywania\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eWilgotność\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0% do 95% wilgotności względnej, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eStopień ochrony\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eIP20 (po zainstalowaniu w standardowej obudowie 3500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eKraj pochodzenia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKonfiguracja sprzętu i kompatybilność czujników\u003c\/h3\u003e\n\u003cp\u003eModuł 172103-01 akceptuje mieszaną konfigurację termopar i RTD w oprogramowaniu konfiguracyjnym szafy 3500. Obsługiwane zakresy czujników przedstawiono poniżej:\u003c\/p\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eTermopara typu E (izolowany czubek):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-100°C do +1000°C (-148°F do +1832°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eTermopara typu J (izolowany czubek):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0°C do +760°C (32°F do +1400°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eTermopara typu K (izolowany czubek):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0°C do +1370°C (32°F do +2498°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eTermopara typu T (izolowany czubek):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-160°C do +400°C (-256°F do +752°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003e100 Ω platynowy RTD (Pt100, alfa = 0,00385):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-200°C do +850°C (-328°F do +1562°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003e100 Ω platynowy RTD (Pt100, alfa = 0,00392):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-200°C do +850°C (-328°F do +1562°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003e120 Ω niklowy RTD (Ni120):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-200°C do +700°C (-328°F do +1292°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003e10 Ω miedziany RTD (Cu10):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-80°C do +260°C (-112°F do +500°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePrzewodnik inżynieryjny i instalacyjny\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eUziemienie i ekranowanie:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEkrany kabli czujników temperatury muszą być zakończone w jednym punkcie. Podłącz przewody ekranów do dedykowanych zacisków uziemienia obudowy w szafie 3500. Nie uziemiać ekranu jednocześnie przy czujniku i module, aby zapobiec pętlom masy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eOgraniczenia termopar:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTylko termopary z izolowanym czubkiem są kompatybilne z modelem 172103-01. Nie wolno stosować termopar z uziemionym czubkiem, ponieważ wprowadzają one błędy napięcia wspólnego trybu na kanałach korzystających z tego samego multipleksera wejściowego.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eOddzielenie okablowania:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePrzewody sygnałowe niskonapięciowe RTD\/TC prowadź przez dedykowane, oddzielne korytka kablowe. Unikaj bliskości przewodów zasilających silnik wysokiego napięcia, wyjść falownika (VFD) lub przełączających obciążeń indukcyjnych, aby zapobiec wprowadzeniu zakłóceń elektromagnetycznych (EMI).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eModyfikacje dla czujników RTD 4-przewodowych:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStandardowe moduły zakończeniowe wewnętrzne są skonfigurowane do kompensacji RTD 3-przewodowych. Jeśli stosowane są czujniki RTD 4-przewodowe, należy sprawdzić konkretny kod modyfikacji sprzętowej (np. Modyfikacja 179952-01) wymaganą do fizycznego dostosowania wieloprzewodowego zworu.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eŚrodki ostrożności przy wymianie na gorąco:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eChociaż główna karta monitora 3500\/65 obsługuje wpinanie i wypinanie online, odłączenie modułu I\/O 172103-01 podczas pracy monitora natychmiast przerwie pętle czujników, wywołując błędy kanałów i potencjalne alarmy niebezpieczeństwa na poziomie szafy. Przed wyjęciem modułu należy obejść wszelką powiązaną logikę głosowania lub blokady wyłączania.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ techniczne\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eCzy mogę używać modułu 172103-01 z zewnętrznym blokiem zakończeniowym?\u003c\/span\u003e\u003cbr\u003eNie. Model 172103-01 jest specjalnie zaprojektowany do wewnętrznych zakończeń, gdzie okablowanie polowe łączy się bezpośrednio z wtyczką tylnej płyty szafy. Dla zewnętrznych bloków zakończeniowych należy zamówić moduł I\/O 172109-01 do zewnętrznego zakończenia.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eCo się dzieje, gdy przewód czujnika temperatury zostanie przerwany lub odłączony?\u003c\/span\u003e\u003cbr\u003eMonitor 3500\/65 automatycznie wykonuje kontrolę limitów przetwornika. Przerwanie przewodu powoduje status „Open Circuit” lub „Not OK” dla danego kanału. Dioda LED Channel OK na przedniej części głównej karty będzie migać, a status wyjścia kanału zostanie ustawiony poza zakres, aby zapobiec fałszywym wyłączeniom maszyny.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eCzy wymagana jest aktualizacja oprogramowania układowego przy wymianie starszego modułu I\/O wersji I na nowy 172103-01?\u003c\/span\u003e\u003cbr\u003eW przypadku modernizacji lub wymiany starszej konfiguracji, należy zweryfikować, czy wersja oprogramowania układowego głównej karty monitora 3500\/65 jest kompatybilna. Niekompatybilne oprogramowanie może powodować niezgodności konfiguracji lub ciągły błąd „Configuration Error” w dzienniku zdarzeń szafy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eJak zarządza się kompensacją zimnego złącza (CJC) dla termopar?\u003c\/span\u003e\u003cbr\u003eModel 172103-01 posiada czujnik temperatury półprzewodnikowy zintegrowany bezpośrednio na płytce z zaciskami. Czujnik ten monitoruje zmiany temperatury zacisków i stosuje cyfrowe współczynniki kompensacji w warstwie przetwarzania monitora 3500\/65.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668298625387,"sku":"172103-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/172103-01-hymuxx01gcp_f9bd0daa-d3f3-4d15-819b-972e3ef918b5.jpg?v=1765520488"},{"product_id":"bently-nevada-3500-61-05-cn-3500-61-temperature-module-with-recorder-outputs","title":"Moduł temperatury Bently Nevada 3500\/61-05-CN 3500\/61 z wyjściami do rejestratora","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e3500\/61-05-CN\u003c\/strong\u003e to moduł pomiarowy o pełnej wysokości i sześciu kanałach, zaprojektowany do ciągłego monitorowania temperatury oraz precyzyjnego proporcjonalnego sygnalizowania analogowego w ramach \u003cstrong\u003eSystemu Ochrony Maszyn Serii 3500\u003c\/strong\u003e. Ten specjalistyczny monitor przyjmuje surowe sygnały z detektorów temperatury rezystancyjnej (RTD) i termopar (TC), przetwarza je i ocenia dane względem programowalnych przez użytkownika progów alarmów alertu i zagrożenia. W odróżnieniu od swojego modułu towarzyszącego, ten komponent zapewnia niezależne wyjścia rejestratora +4 do +20 mA dla każdego z sześciu kanałów, umożliwiając bezproblemową integrację z zewnętrznymi systemami sterowania rozproszonego (DCS), rejestratorami taśmowymi lub rejestratorami danych na poziomie zakładu. Pracując w standardowej ramie 3500, obsługuje konfigurację w terenie za pomocą oprogramowania do konfiguracji szafy 3500 i umożliwia układy nieizolowane z wewnętrznymi barierami bezpieczeństwa, aby zachować integralność pętli w różnych środowiskach przemysłowych maszyn.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSześć kompleksowych kanałów monitorowania temperatury akceptujących mieszane kombinacje czujników RTD i termopar.\u003c\/li\u003e\n\u003cli\u003eDedykowane analogowe wyjścia rejestratora +4 do +20 mA na kanał, proporcjonalne do wartości monitorowanych na pełnej skali i całkowicie odporne na zewnętrzne zwarcia.\u003c\/li\u003e\n\u003cli\u003eZintegrowane programowalne w oprogramowaniu nastawy Alert i Danger obejmujące 0 do 100% aktywnej skali czujnika.\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne opóźnienia czasowe alarmu regulowane od 1 do 60 sekund, aby ograniczyć fałszywe wyzwolenia sygnału.\u003c\/li\u003e\n\u003cli\u003eDiody LED diagnostyczne na panelu przednim zapewniające natychmiastową ocenę statusu Modułu OK, trybu obejścia oraz aktywnego ruchu komunikacji TX\/RX.\u003c\/li\u003e\n\u003cli\u003eWsparcie dla nieizolowanych architektur I\/O z wewnętrznymi barierami bezpieczeństwa chroniącymi delikatne pętle przetwarzania.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCiągłe śledzenie termiczne uzwojeń stojana silników i generatorów przemysłowych.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie temperatury łożysk promieniowych i osiowych w krytycznych turbinach, pompach i sprężarkach przemysłowych.\u003c\/li\u003e\n\u003cli\u003eRejestracja temperatury spalin dla turbin gazowych i ciężkich maszyn przetwórczych.\u003c\/li\u003e\n\u003cli\u003eWielokanałowa logika głosowania temperatury do integracji z automatycznymi systemami wyłączania maszyn.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKategoria\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDane\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElektryczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZużycie energii\u003c\/td\u003e\n\u003ctd\u003e9 wat nominalnie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePojemność sygnału wejściowego\u003c\/td\u003e\n\u003ctd\u003e1 do 6 sygnałów przetworników RTD lub TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eImpedancja wejściowa\u003c\/td\u003e\n\u003ctd\u003e10 MOhm na każde wejście przewodu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWartość źródła prądu RTD\u003c\/td\u003e\n\u003ctd\u003e925 +\/-15 mikroA @ 25°C na przetwornik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjścia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSygnał wyjściowy rejestratora\u003c\/td\u003e\n\u003ctd\u003e+4 do +20 mA DC (proporcjonalnie do pełnej skali)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eZakres napięcia zgodności\u003c\/td\u003e\n\u003ctd\u003e0 do +12 V DC na obciążeniu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eZakres rezystancji obciążenia\u003c\/td\u003e\n\u003ctd\u003e0 do 600 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRozdzielczość rejestratora\u003c\/td\u003e\n\u003ctd\u003e0,3662 mikroA na bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBłąd rejestratora\u003c\/td\u003e\n\u003ctd\u003e+\/-0,15% w temperaturze pokojowej, +\/-0,4% w całym zakresie temperatur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWydajność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZakres nastawy alarmu\u003c\/td\u003e\n\u003ctd\u003eRegulowana od 0 do 100% pełnej skali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDokładność nastawy alarmu\u003c\/td\u003e\n\u003ctd\u003eW granicach 0,13% wartości docelowej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInterwały opóźnienia alarmu\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund w odstępach co 1 sekundę\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInterwały opóźnienia zagrożenia\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund w odstępach co 0,5 sekundy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRozdzielczość temperatury\u003c\/td\u003e\n\u003ctd\u003e1°C lub 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŚrodowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperatura pracy (bariery wewnętrzne)\u003c\/td\u003e\n\u003ctd\u003e0°C do +65°C (32°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eZakres temperatury przechowywania\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWilgotność pracy otoczenia\u003c\/td\u003e\n\u003ctd\u003eMaksymalna wilgotność otoczenia 95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechaniczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWymiary modułu monitora (W x S x G)\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWaga modułu monitora\u003c\/td\u003e\n\u003ctd\u003e0,91 kg (2,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi (W x S x G)\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm (9,50 cala x 0,96 cala x 6,42 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWaga modułu I\/O z barierami wewnętrznymi\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWymagania dotyczące przestrzeni z przodu szafy\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe gniazdo przednie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWymagania dotyczące przestrzeni z tyłu szafy\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe gniazdo tylne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterfejs zacisków \/ komponentów\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED OK na panelu przednim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWskazuje, że monitor temperatury działa prawidłowo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED TX\/RX na panelu przednim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiga, aby wskazać aktywną komunikację z innymi modułami w szafie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED obejścia na panelu przednim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eŚwieci, gdy kanał lub monitor jest ustawiony w tryb obejścia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTylne zaciski I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBezpośrednie punkty zakończenia dla fizycznego okablowania RTD i termopar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfejs wyjścia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePołączenia równoległe zapewniające niezależne pętle diagnostyczne +4 do +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWkładanie głównej karty:\u003c\/strong\u003e Zamontuj główny moduł monitora w dowolnym dostępnym pełnowymiarowym gnieździe po prawej stronie modułu interfejsu szafy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePozycjonowanie modułu I\/O:\u003c\/strong\u003e Zainstaluj dopasowany moduł I\/O RTD\/TC z barierą wewnętrzną nieizolowaną w odpowiednim pełnowymiarowym gnieździe z tyłu, bezpośrednio za głównym monitorem przednim.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOdciążenie kabla:\u003c\/strong\u003e Prowadź przewody czujników zewnętrznych oddzielnie od hałaśliwych linii wysokiego napięcia, aby wyeliminować zakłócenia elektromotoryczne w obwodach nieizolowanych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeryfikacja konfiguracji:\u003c\/strong\u003e Przed uruchomieniem zakładu określ precyzyjne krzywe czujników (wartości alfa) oraz atrybuty skalowania w narzędziu 3500 Configuration Software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e 2014\/30\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy EMC:\u003c\/strong\u003e EN 61000-6-2 (odporność na zakłócenia w środowiskach przemysłowych), EN 61000-6-4 (emisje w środowiskach przemysłowych), EN 55011 Klasa A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Dyrektywa niskonapięciowa 2014\/35\/UE; EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożonych (z barierami wewnętrznymi):\u003c\/strong\u003e CSA\/NRTL\/C Klasa I, Dywizja 2, Grupy A, B, C i D (z wyjściem IS dla Dywizji 1); Klasa I, Strefa 2: AEx\/Ex nA nC ic [ia Ga] IIC T4 Gc lub AEx\/Ex ec nC ic [ia Ga] IIC T4 Gc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (z barierami wewnętrznymi):\u003c\/strong\u003e Ex II 3(1) G; Ex nA nC ic [ia Ga] IIC T4 Gc lub Ex ec nC ic [ia Ga] IIC T4 Gc w temperaturze Ta = -20°C do +65°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo funkcjonalne:\u003c\/strong\u003e Zaprojektowano tak, aby spełniać wymagania SIL 2.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668299379051,"sku":"3500\/61-05-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-61-05-CN-cfhoqahh0w4_028b5b49-848f-4c41-80b1-1f94bb49297c.jpg?v=1765520500"},{"product_id":"bently-nevada-136188-01-3500-series-ethernet-rs232-modbus-i-o-module","title":"Moduł I\/O Bently Nevada 136188-01 serii 3500 Ethernet\/RS232 Modbus","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojaktowany do bezproblemowej integracji w ramach przemysłowych architektur monitoringu, \u003cstrong\u003e136188-01\u003c\/strong\u003e pełni funkcję tylnej płytki interfejsu I\/O dla modułu bramki komunikacyjnej Bently Nevada 3500\/92. Ten wytrzymały \u003cstrong\u003emoduł I\/O Ethernet\/RS232 Modbus\u003c\/strong\u003e zapewnia bezpieczne i efektywne cyfrowe połączenia komunikacyjne między systemami ochrony maszyn 3500 a zewnętrznymi zasobami zakładu, takimi jak rozproszone systemy sterowania (DCS), programowalne sterowniki logiczne (PLC) oraz platformy SCADA.\u003c\/p\u003e\n\n\u003cp\u003eDzięki połączeniu wysokowydajnych możliwości Ethernet oraz tradycyjnej łączności szeregowej, moduł umożliwia tłumaczenie i przesyłanie statycznych i dynamicznych danych maszyn. Ten interfejs gwarantuje dostępność parametrów diagnostycznych w czasie rzeczywistym oraz statusów alarmów w całej sieci zakładowej, nie naruszając podstawowych funkcji bezpieczeństwa i wyłączania systemu ochrony.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePodwójna architektura interfejsu z dedykowanymi portami fizycznymi RJ45 Ethernet i szeregowym RS232.\u003c\/li\u003e\n  \u003cli\u003eBezpośrednie połączenie z płytką tylnego panelu zaprojektowane specjalnie dla systemu szaf 3500 Bently Nevada.\u003c\/li\u003e\n  \u003cli\u003eObsługa jednoczesnych konfiguracji komunikacyjnych dla optymalizacji integracji systemu.\u003c\/li\u003e\n  \u003cli\u003eWytrzymała konstrukcja zapewniająca wysoką niezawodność w trudnych warunkach przemysłowych.\u003c\/li\u003e\n  \u003cli\u003eObsługa szybkich protokołów danych Modbus TCP\/IP oraz standardowego Modbus RTU.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMonitorowanie systemów turbin parowych i gazowych w elektrowniach.\u003c\/li\u003e\n  \u003cli\u003eOperacje wydobycia i rafinacji ropy naftowej i gazu.\u003c\/li\u003e\n  \u003cli\u003eZakłady przetwórstwa petrochemicznego.\u003c\/li\u003e\n  \u003cli\u003eNadzór nad ciężkimi maszynami obrotowymi w przemyśle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer katalogowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e136188-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSystem ochrony maszyn serii 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eModuł I\/O Ethernet \/ RS232 Modbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKompatybilny moduł bramki\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3500\/92 Communication Gateway\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePort interfejsu Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1x RJ45 (kompatybilny z 10Base-T\/100Base-TX)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePort interfejsu szeregowego\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1x RS232 DB9\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eObsługiwane protokoły\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eModbus TCP, Modbus RTU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWaga wysyłkowa\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3,0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTyp portu\u003c\/th\u003e\n      \u003cth\u003eStandard złącza\u003c\/th\u003e\n      \u003cth\u003eGłówna funkcja protokołu\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePort Ethernet\u003c\/td\u003e\n      \u003ctd\u003eRJ45\u003c\/td\u003e\n      \u003ctd\u003eKomunikacja Modbus TCP klient\/serwer przez LAN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePort szeregowy\u003c\/td\u003e\n      \u003ctd\u003eRS232 (DB9)\u003c\/td\u003e\n      \u003ctd\u003eKonfiguracja punkt-punkt i diagnostyka Modbus RTU\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cp\u003ePoprawna instalacja fizyczna oraz uziemienie elektryczne są kluczowe, aby zapobiec uszkodzeniu danych lub sprzętu. Należy przestrzegać następujących kroków inżynieryjnych:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWyrównanie slotów:\u003c\/strong\u003e Zamontuj moduł I\/O 136188-01 w tylnym slocie szafy 3500, bezpośrednio za odpowiadającym mu głównym modułem bramki komunikacyjnej 3500\/92.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSekwencja zasilania:\u003c\/strong\u003e Upewnij się, że zasilanie szafy jest wyłączone lub że są ściśle przestrzegane procedury hot-swap podczas wkładania modułu, aby chronić układy transceivera magistrali przed przepięciami.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEkranowanie i okablowanie:\u003c\/strong\u003e Używaj wysokiej jakości ekranowanego kabla przemysłowego Ethernet kategorii 5e (lub lepszego). Do połączeń szeregowych RS232 stosuj ekranowane kable o niskiej pojemności i ogranicz długość do standardowego progu 15 metrów.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUziemienie:\u003c\/strong\u003e Zapewnij prawidłowe uziemienie obudowy 3500 do systemu uziemienia o niskiej impedancji, aby chronić delikatne linie sygnałowe przed zakłóceniami elektromagnetycznymi (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668301443435,"sku":"136188-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/136188-01-oreoavsu1xk_66140140-1c4d-4f47-96f7-c88c3a57c080.jpg?v=1765520550"},{"product_id":"bently-nevada-163179-02-3500-60-temperature-monitor-i-o-module","title":"Bently Nevada 163179-02 3500\/60 Temperature Monitor I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding highly reliable thermal sensor integration within industrial machinery protection systems, the \u003cstrong\u003eBently Nevada 163179-02\u003c\/strong\u003e serves as the dedicated RTD\/TC Non-Isolated I\/O Module with Internal Terminations. Engineered specifically for use with the 3500\/60 and 3500\/61 Temperature Monitor series, this hardware interface accepts inputs from both Resistive Temperature Detectors (RTD) and Thermocouples (TC). Its internal termination design eliminates the need for external terminal blocks, simplifying control cabinet layouts and reducing field wiring complexity. Each module connects directly to the backplane of the 3500 rack, transmitting digitized temperature data to the main monitor module for real-time safety trips and machinery diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Sensor Connection:\u003c\/strong\u003e Supports dual-element RTDs and various thermocouple calibrations without external signal conditioning.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInternal Terminations:\u003c\/strong\u003e Integrated terminal strips located directly on the card ease point-to-point field wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Isolated Architecture:\u003c\/strong\u003e Cost-efficient, space-saving design optimized for installations sharing a common instrumentation ground.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDynamic Hot-Swapping:\u003c\/strong\u003e Minimizes system downtime by allowing rear module replacement while keeping adjacent modules online.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachinery Protection Integration:\u003c\/strong\u003e Communicates seamlessly with the 3500 backplane to trigger automatic emergency trip limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eRadial and thrust bearing temperature monitoring in heavy steam or gas turbines.\u003c\/li\u003e\n  \u003cli\u003eThermal monitoring of generator stator windings and rotor bearing housings.\u003c\/li\u003e\n  \u003cli\u003eContinuous casing and process gas temperature diagnostics in centrifugal compressors.\u003c\/li\u003e\n  \u003cli\u003eHigh-capacity electric motor protection in critical petrochemical and mining facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eSpecification Values\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e163179-02 (Component of 3500\/60)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRTD\/TC Non-Isolated I\/O Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTermination Style\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eInternal Terminations (Screw clamp terminals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCompatible Monitors\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500\/60 and 3500\/61 Temperature Monitors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eThermocouple Types\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eType J, K, T, E (with cold-junction compensation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRTD Types\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100 ohm Platinum (3-wire and 4-wire configurations)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-30 degC to +65 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe rear terminal strip provides hardwired connections for up to six separate temperature channels. Use shielded twisted-pair cabling for all RTD and TC inputs to maintain noise immunity.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eTerminal Label\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eRTD Mode Connection\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eThermocouple Mode Connection\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eA\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSource \/ Lead Compensation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNo Connection (Open)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eB\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSignal (+) Return\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePositive (+) Leg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCommon (-) Return\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNegative (-) Leg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSHIELD\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eInstrument Ground Shield\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eInstrument Ground Shield\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 163179-02 non-isolated module features integrated internal termination blocks. If replacing older external termination setups (such as the 133900-01 board), you must convert your wiring topology to land directly on this rear module. Ensure that the main front-facing 3500\/60 or 3500\/61 processor card runs compatible firmware to correctly recognize the non-isolated parameter set.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this module is non-isolated, all input grounds share a common reference potential inside the 3500 rack. Avoid using non-isolated sensors in electrically noisy settings or in plants experiencing ground grid variance, as this can lead to phantom temperature spikes, high-level noise on signal loops, or false alarm triggers. If sensors are ungrounded at the field junction, always tie the cable shields directly to the chassis ground terminal of this I\/O module.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor installations utilizing thermocouples, allow the internal cold junction compensation (CJC) circuit to thermally stabilize for 15 to 20 minutes after cabinet power-up before taking baseline commissioning readings. Always route instrument-level RTD\/TC wiring through isolated cable trays away from high-voltage motor feeds to mitigate electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eDe-energize the entire 3500 chassis and isolate all auxiliary trip loops before extracting or installing rear I\/O cards. Failure to bypass active protection outputs could result in an accidental plant shut down or equipment trip.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003ePower down the rack or switch the front-panel keyswitch to \"Program Mode\" to inhibit auto-trips.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eAlign the 163179-02 card with the designated guide rails on the rear chassis slot corresponding to the monitor module.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eSlide the module firmly forward into the backplane connectors until the mounting screws line up with the rack frame.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eTighten the retaining screws to ground the module housing properly. Secure all sensor channels onto the internal screw terminals.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668304097643,"sku":"3500\/60 163179-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/163179-02_-jj4mrhjwcqo_a907a3e8-2b77-42d7-bb7c-27ec4ba8d612.jpg?v=1765521155"},{"product_id":"bently-nevada-3500-61-01-cn-temperature-module-with-recorder-outputs","title":"Moduł temperatury Bently Nevada 3500\/61-01-CN z wyjściami rejestratora","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003ePrzetworzona karta monitorująca \u003cstrong\u003e3500\/61-01-CN\u003c\/strong\u003e oferuje sześć niezależnych kanałów ciągłego monitorowania temperatury i przetwarza sygnały z czujników Rezystancyjnego Detektora Temperatury (RTD) oraz Termopary (TC) w ramach systemu ochrony maszyn Bently Nevada serii 3500. Moduł ten próbuje analogowe sygnały fizyczne, kondycjonuje surowe sygnały wejściowe i wykonuje cykle porównawcze względem progów alarmowych zaprogramowanych przez użytkownika. Konstrukcja \u003cstrong\u003e3500\/61\u003c\/strong\u003e zawiera dedykowane wyjścia prądowe rejestratora analogowego dla każdego z sześciu wewnętrznych kanałów, umożliwiając interfejs telemetrii w czasie rzeczywistym do równoległych pętli instrumentacyjnych.\u003c\/p\u003e\n\u003cp\u003eDziałając w złożonych rozproszonych sieciach maszynowych, moduł typu \u003cstrong\u003e3500\/61-01-CN\u003c\/strong\u003e współpracuje natywnie z oprogramowaniem konfiguracyjnym szafy 3500 do definiowania niestandardowych definicji czujników lub różnych profili mieszania przetworników. W przypadku zastosowania w bloku bezpieczeństwa Triple Modular Redundant (TMR) moduły te są umieszczane obok siebie w grupach po trzy, realizując dwupoziomową logikę głosowania, aby wyeliminować ryzyko awarii pojedynczego punktu w sieciach maszynowych. Konfiguracja ta wykorzystuje nieizolowany komponent I\/O RTD\/TC z wewnętrznymi zaciskami śrubowymi i posiada specyficzną lokalną aprobatę agencji CN, zapewniającą łączność w terenie w obrębie łożysk obrotowych maszyn przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSześć w pełni konfigurowalnych kanałów obsługujących mieszane przetwarzanie sygnałów z czujników termoparowych i RTD.\u003c\/li\u003e\n\u003cli\u003eSześć dedykowanych proporcjonalnych wyjść analogowych +4 do +20 mA do rejestratorów zapewniających czyste śledzenie telemetrii do zewnętrznych węzłów.\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne opóźnienia alarmów i parametry powiadomień o nastawach zarządzane przez natywne oprogramowanie interfejsu szafy.\u003c\/li\u003e\n\u003cli\u003eWsparcie sprzętowe dla konfiguracji głosowania wielokartowego Triple Modular Redundant (TMR) w celu zwiększenia integralności pętli zakładu.\u003c\/li\u003e\n\u003cli\u003eWewnętrzna konstrukcja zakończeń z wytrzymałymi blokami zaciskowymi śrubowymi do uproszczenia bezpośrednich połączeń okablowania w terenie.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCiągłe monitorowanie temperatury promieniowej łożysk i termiczne śledzenie uzwojeń stojana w turbinach parowych i gazowych do napędu użytkowego.\u003c\/li\u003e\n\u003cli\u003eWielokanałowe monitorowanie temperatury spalin i ochrona termiczna obudowy wysokociśnieniowej w sprężarkach odśrodkowych procesowych.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie blokady bezpieczeństwa łożysk silników krytycznych i wysokowydajnych pomp przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNumer części \/ kod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis wyboru\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/61-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł temperatury 3500\/61 z wyjściami rejestratora\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O RTD\/TC nieizolowany z wewnętrznymi zakończeniami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: CN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzeń: Specyficzne lokalne konfiguracje zgodności agencji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKlasyfikacja parametrów\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrecyzyjne wartości inżynieryjne\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGłówny numer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/61-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł temperatury z wyjściami rejestratora\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCałkowita liczba kanałów\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kanałów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObsługiwane wejścia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD (100 omów platyny, 120 omów niklu, 10 omów miedzi) oraz termopary (typ E, J, K, T, R, S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWiększa niż 221 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksymalna typowa moc 7,0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjście prądu rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProporcjonalny zakres wyjścia prądowego +4 do +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalne obciążenie rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRozdzielczość\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,3125 mikroampera na bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzas aktualizacji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksymalny czas aktualizacji 1 sekunda na kanał\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22 stopni Celsjusza do +150 stopni Celsjusza)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGranice temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40 stopni Celsjusza do +185 stopni Celsjusza)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGranice wilgotności względnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksymalna wilgotność względna 95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga głównej karty monitorującej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,73 kg (1,6 funta)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,31 kg (0,69 funta)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu głównego (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePołączenie bloku zaciskowego\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji i układ okablowania\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWejścia kanałów 1 do 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWejściowe zaciski śrubowe dla stałych RTD 3-przewodowych\/4-przewodowych lub określonych par przewodów termopar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjścia rejestratora 1 do 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane zaciski wyjściowe pętli prądowej (+4 do +20 mA) do zewnętrznego dopasowania monitoringu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSekwencja gniazd w stojaku:\u003c\/strong\u003e Zainstaluj przednią płytę procesora monitorującego w dowolnym pełnowymiarowym gnieździe obudowy 3500 i przymocuj wewnętrzny moduł zakończenia tylnego I\/O bezpośrednio po przeciwnej stronie płyty tylnej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKroki uziemienia ekranu:\u003c\/strong\u003e Zakończ zewnętrzne metalowe oploty ekranów wszystkich przewodów czujników polowych czysto na najbliższym szynie uziemiającej obudowy na stojaku, aby tłumić zewnętrzne zakłócenia elektryczne.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyrównywanie przewodów:\u003c\/strong\u003e Podczas używania długodystansowych przedłużeń RTD należy zapewnić stosowanie przewodów o dopasowanej grubości i długości we wszystkich trzech przewodach, aby utrzymać dokładne śledzenie wewnętrznej rezystancji pętli.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZapobieganie elektrostatyczne:\u003c\/strong\u003e Personel konserwacyjny musi pozostawać połączony z uziemieniem urządzenia za pomocą zatwierdzonej przewodzącej opaski uziemiającej przed wyciągnięciem, inspekcją lub włożeniem jakichkolwiek struktur kart procesora.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668307603819,"sku":"3500\/61-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350061-01-CN-ls515xj2f5y_45df22ef-c683-4cf7-8b6e-c6a415a22590.jpg?v=1765520724"},{"product_id":"bently-nevada-133300-01-3500-series-low-voltage-dc-power-input-module","title":"Moduł zasilania niskiego napięcia DC Bently Nevada 133300-01 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZaprojketowany do bezpośredniego współdziałania z systemem zasilania 3500\/15, \u003cstrong\u003eBently Nevada 133300-01\u003c\/strong\u003e zapewnia regulowane wejście niskonapięciowego prądu stałego do stojaka ochrony maszyn 3500. Ten moduł montowany z tyłu akceptuje \u003cstrong\u003e20 do 30 VDC\u003c\/strong\u003e i kondycjonuje zasilanie podstawowe przed przekazaniem go do wewnętrznej szyny. Zaprojektowany do środowisk o wysokiej niezawodności, jest kluczowy dla utrzymania ciągłego monitorowania maszyn i ochrony krytycznych wirujących elementów przed nieoczekiwanymi przerwami w zasilaniu.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eBezproblemowa integracja z zasilaczem niskonapięciowym DC 3500\/15.\u003c\/li\u003e\n  \u003cli\u003eObsługuje w pełni redundantne konfiguracje zasilania przy zastosowaniu dodatkowego tylnego modułu.\u003c\/li\u003e\n  \u003cli\u003eWytrzymałe połączenia zaciskowe zaprojektowane do pracy w warunkach przemysłowych drgań.\u003c\/li\u003e\n  \u003cli\u003eWbudowana ochrona przed przeciążeniem i filtracja zakłóceń elektromagnetycznych (EMI).\u003c\/li\u003e\n  \u003cli\u003ePasywne chłodzenie zoptymalizowane do ciągłej pracy w stojaku.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSystemy monitorowania drgań turbin parowych i gazowych.\u003c\/li\u003e\n  \u003cli\u003eSystemy ochrony generatorów hydroelektrycznych.\u003c\/li\u003e\n  \u003cli\u003eStojaki bezpieczeństwa sprężarek i pomp w zakładach petrochemicznych.\u003c\/li\u003e\n  \u003cli\u003eCiężkie przemysłowe zakłady wytwarzania i dystrybucji energii.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 40%;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNumer części\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e133300-01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeria\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTyp modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModuł wejściowy zasilania niskonapięciowego DC (LVDCI)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eZakres napięcia wejściowego\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eZakres napięcia wejściowego 20 do 30 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eKompatybilne zasilanie przednie\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModuł zasilania niskonapięciowego DC 3500\/15\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMiejsce montażu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSlot tylnej obudowy (półwysokość)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTemperatura pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: -0.75rem;\"\u003e-30 do +65 stopni Celsjusza\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUSA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1,50 kg (3,30 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWymiary opakowania (obliczone)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24,1 cm x 11,2 cm x 5,1 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; width: 40%;\"\u003eKońcówka bloku zaciskowego\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunkcja \/ przypisanie obwodu\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDodatni (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e+24 VDC podstawowe zasilanie wejściowe\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eUjemny (-)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePowrót DC \/ wspólne\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eUziemienie obudowy (GND)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePołączenie systemowe \/ uziemienie ochronne dla ciągłości ekranu\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eEmpiryczne spostrzeżenia inżynierskie\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eModuł 133300-01 jest specjalnie przeznaczony do niskonapięciowej wersji zasilacza 3500\/15. Jest fizycznie i elektrycznie niekompatybilny z modułami wysokiego napięcia AC\/DC (takimi jak 129767-01 lub 120739-01). Zawsze sprawdzaj napięcie modułu 3500\/15 z przodu przed gorącą wymianą lub wymianą elementów tylnego wejścia.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eW konfiguracjach z podwójną redundancją upewnij się, że oba źródła niskonapięciowego prądu stałego pochodzą z niezależnych wyłączników lub źródeł zasilania. Jeśli oba wejścia są podłączone do tego samego obwodu zasilającego, redundancja systemu jest skutecznie pomijana. Unikaj prowadzenia surowego, nieprzefiltrowanego prądu stałego bezpośrednio do tych zacisków; stosuj zewnętrzne kondycjonowanie linii, jeśli długie przewody są narażone na zakłócenia indukcyjne.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUżywaj przewodów o minimalnym przekroju 14 AWG (2,1 mm2), aby zapobiec nadmiernym spadkom napięcia na odcinkach przekraczających 10 metrów. Upewnij się, że śruby zacisków są dokręcone dokładnie do momentu 0,56 Nm (5 in-lb), aby utrzymać pewne połączenia podczas ciągłych drgań wysokiej częstotliwości maszyn.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eOSTRZEŻENIE KRYTYCZNE\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eOdłącz zasilanie wszystkich głównych źródeł prądu stałego przed instalacją, demontażem lub okablowaniem tylnego modułu wejściowego. Serwisowanie połączeń pod napięciem może spowodować niebezpieczne łuki elektryczne, lokalne uszkodzenia styków lub krytyczne uszkodzenia elementów płyty tylnej.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eUpewnij się, że główny wyłącznik zasilania szafy 3500 jest w pozycji WYŁ., a wyłącznik źródła prądu stałego jest zablokowany.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWyrównaj krawędzie karty modułu 133300-01 z prowadnicami kart w wyznaczonym tylnym slocie o połowie wysokości.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePrzesuń moduł mocno do przodu, aż jego złącze całkowicie połączy się z złączami płyty tylnej.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eZabezpiecz śruby mocujące płytkę czołową i załóż osłonę zacisków po zakończeniu okablowania w terenie.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308128107,"sku":"133300-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/133300-01-ry5osi23wfo_6abd5e5b-a071-487b-b77b-e56c673e66b4.jpg?v=1765520743"},{"product_id":"bently-nevada-176449-08-3500-series-rod-position-monitor-i-o-module","title":"Bently Nevada 176449-08 3500 Series Rod Position Monitor I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo track the exact dynamic displacement of piston rods in reciprocating compressors, the \u003cstrong\u003eBently Nevada 176449-08\u003c\/strong\u003e functions as a highly specialized I\/O module within the 3500 Machinery Protection System. This module interfaces directly with the 3500\/72M Reciprocating Compressor Rod Position Monitor, processing signal inputs from proximity probes and seismic transducers to ensure precise tracking of rod runout and position. By offering \u003cstrong\u003einternal termination\u003c\/strong\u003e capabilities, this unit simplifies cabinet wiring and eliminates the need for external termination blocks, directly improving signal integrity and reducing installation footprints in critical petrochemical and gas processing plants.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eFour-channel input capability supporting both Proximitor and seismic transducers.\u003c\/li\u003e\n  \u003cli\u003eInternal termination architecture to streamline cabinet design and lower point-to-point wiring risks.\u003c\/li\u003e\n  \u003cli\u003eDirect backplane communication for high-speed data transmission to the main 3500 system rack.\u003c\/li\u003e\n  \u003cli\u003eDesigned for harsh industrial environments, ensuring continuous monitoring of critical reciprocating machinery.\u003c\/li\u003e\n  \u003cli\u003eHot-swappable design allows replacement of the physical I\/O card without shutting down the entire protection rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eReciprocating compressor rod runout and mean position tracking.\u003c\/li\u003e\n  \u003cli\u003eCrosshead vibration measurement in high-pressure process gas systems.\u003c\/li\u003e\n  \u003cli\u003eContinuous industrial machinery health monitoring and protective tripping loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e176449-08\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eCompatible Monitor Module\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e3500\/72M Reciprocating Compressor Monitor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eTermination Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eInternal Termination\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eInput Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e4 Channels (Proximitor \/ Seismic)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eHost rack powered (nominal backplane draw)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-30 to +65 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-40 to +85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eHumidity Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e95% non-condensing relative humidity\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e3.0 kg (6.6 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e28.5 x 19.0 x 6.5 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe internal termination card provides a series of dedicated terminal blocks designed for secure field-wire attachment. Below is the typical pinout configuration layout for the input channels:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eTerminal Terminal Group\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eLabel Name\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eSignal Assignment \/ Function\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\" rowspan=\"3\"\u003e\u003cstrong\u003eChannel 1 Block\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-24V\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eTransducer Power Output (Channel 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Input (Channel 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Common (Channel 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\" rowspan=\"3\"\u003e\u003cstrong\u003eChannel 2 Block\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-24V\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eTransducer Power Output (Channel 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Input (Channel 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Common (Channel 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\" rowspan=\"3\"\u003e\u003cstrong\u003eChannel 3 Block\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-24V\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eTransducer Power Output (Channel 3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Input (Channel 3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Common (Channel 3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\" rowspan=\"3\"\u003e\u003cstrong\u003eChannel 4 Block\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-24V\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eTransducer Power Output (Channel 4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Input (Channel 4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Common (Channel 4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e\u003cstrong\u003eChassis Ground\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSHLD\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eShield Terminal (Internal Ring Connection to Rack Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 176449-08 is designed specifically for standard internal termination setups. It is not directly interchangeable with external termination (ET) versions (such as the 176449-01 through 176449-07 variations) unless you also replace the external terminal block and connection cables. Always verify the module suffix matched on the existing chassis slot card before installation to avoid channel mismatched configuration faults in the 3500\/72M monitor.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing this module for reciprocating rod runout measurements, ensure that the proximity probe target areas on the piston rods are completely free of surface scratches, mechanical runout, and electrical runout. Ground loops are a common source of signal distortion; transducer shields must be grounded only at the 3500 rack ground terminals on the 176449-08 I\/O card and cut back and isolated at the machine junction box.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUse 3-wire shielded, twisted-pair cable for all transducer runs back to the I\/O module. After installation, verify the DC gap voltage utilizing the 3500 Rack Configuration Software before commissioning. An incorrect transducer setting or a misaligned physical sensor gap will trigger a \"NOT OK\" channel status light on the front panel of the corresponding 3500\/72M monitor card.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eAlways verify that the 3500 monitor rack is fully de-energized or the specific monitor channel has been bypassed and bypassed outputs are locked out before inserting or removing the I\/O module. Direct hot-swapping under active process trip loops can cause catastrophic machinery shutdown signals to the Distributed Control System (DCS) or Safety Instrumented System (SIS).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePower down the immediate slot or verify that the 3500\/72M monitor associated with the slot is in \"Bypass\" status.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWear a grounded ESD wrist strap before handling the sensitive internal circuit board of the 176449-08 module.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSlide the I\/O module into the rear slots of the 3500 chassis until the connector seating pins are securely in position.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSecure the integrated thumbscrews tightly to ensure continuous chassis grounding and physical retention.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668309537131,"sku":"176449-08","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/176449-08-oiaw2ohsfqx_97a0c840-86fb-4948-86e9-0af87bc1f285.jpg?v=1765520799"},{"product_id":"bently-nevada-3500-61-01-00-3500-series-temperature-monitor-with-recorder-outputs","title":"Bently Nevada 3500\/61-01-00 Monitor temperatury serii 3500 z wyjściami rejestratora","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojketowany do ciągłej ochrony maszyn, \u003cstrong\u003eBently Nevada 3500\/61-01-00\u003c\/strong\u003e przetwarza sygnały temperatury z detektorów temperatury rezystancyjnej (RTD) oraz termopar (TC). Ten sześciokanałowy moduł nieustannie porównuje te sygnały temperatury z ustawionymi przez użytkownika progami alarmowymi, chroniąc krytyczne maszyny przemysłowe przed uszkodzeniami termicznymi. Wariant \u003cstrong\u003e3500\/61-01-00\u003c\/strong\u003e jest skonfigurowany z nieizolowanymi modułami I\/O RTD\/TC wykorzystującymi wewnętrzne zakończenia, zapewniającymi czyste, bezpośrednie połączenia przewodów wewnątrz obudowy szafy.\u003c\/p\u003e\n\n\u003cp\u003eOprócz aktywnego monitorowania alarmów, moduł ten oferuje dedykowane analogowe wyjścia rejestratora dla każdego z sześciu kanałów. Wyjścia te dostarczają proporcjonalne, ciągłe sygnały do zewnętrznych systemów sterowania, takich jak Rozproszone Systemy Sterowania (DCS), Programowalne Sterowniki Logiczne (PLC) lub rejestratory taśmowe, zapewniając płynne rejestrowanie danych historycznych i wizualizację procesów.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCiągłe monitorowanie do sześciu niezależnych kanałów temperatury.\u003c\/li\u003e\n  \u003cli\u003eKompatybilny zarówno z termoparami, jak i czujnikami RTD.\u003c\/li\u003e\n  \u003cli\u003eZapewnia niezależne analogowe wyjścia rejestratora dla każdego kanału do współpracy z systemami zewnętrznymi.\u003c\/li\u003e\n  \u003cli\u003eWykorzystuje konfigurację modułu I\/O z wewnętrznymi zakończeniami do bezpośredniego okablowania na płycie.\u003c\/li\u003e\n  \u003cli\u003eObsługuje konfigurowalne alarmy, w tym progi Alert i Danger, z programowalnymi opóźnieniami czasowymi.\u003c\/li\u003e\n  \u003cli\u003eW pełni integruje się z systemem ochrony maszyn Bently Nevada 3500, szyną, płytą tylnią i oprogramowaniem.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMonitorowanie temperatury łożysk turbin parowych, gazowych i wodnych.\u003c\/li\u003e\n  \u003cli\u003eOchrona uzwojeń i stojanów dużych silników elektrycznych i generatorów.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie temperatury obudów sprężarek i pomp przemysłowych.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie przekładni przemysłowych, obudów maszyn oraz zbiorników oleju smarnego.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParametr\u003c\/th\u003e\n      \u003cth\u003eSpecyfikacja\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3500\/61-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSystem ochrony maszyn serii 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMonitor temperatury z wyjściami rejestratora\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja modułu I\/O (-01)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNieizolowany moduł I\/O RTD\/TC z wewnętrznymi zakończeniami\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja zatwierdzenia agencji (-00)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrak\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLiczba kanałów\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6 kanałów na moduł\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTypy sygnałów wejściowych\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTermopary (TC) i detektory temperatury rezystancyjnej (RTD)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWyjścia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6 analogowych wyjść rejestratora (proporcjonalnych do temperatury kanału)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWaga wysyłkowa\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3,0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePołączenie zaciskowe\u003c\/th\u003e\n      \u003cth\u003eOpis funkcji pinu\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZaciski Ch 1 - Ch 6\u003c\/td\u003e\n      \u003ctd\u003eBezpośrednie zakończenia przewodów RTD lub termopar (nieizolowane)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWyjścia rejestratora\u003c\/td\u003e\n      \u003ctd\u003eDedykowana analogowa pętla sygnału prądowego lub napięciowego na kanał\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInterfejs płyty tylnej\u003c\/td\u003e\n      \u003ctd\u003eProprietarny złącze systemu 3500 do zasilania i komunikacji danych\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUpewnij się, że system szafy 3500 jest całkowicie wyłączony przed włożeniem lub wyjęciem modułu I\/O lub płyty głównej monitora.\u003c\/li\u003e\n  \u003cli\u003ePoprawnie zabezpiecz wewnętrzne bloki zakończeniowe za pomocą śrub mocujących moduł, aby zapewnić niezawodny kontakt fizyczny i elektryczny z płytą tylną.\u003c\/li\u003e\n  \u003cli\u003eUżywaj ekranowanych przewodów skręcanych dla wszystkich czujników, aby zminimalizować zakłócenia elektromagnetyczne (EMI) i radiowe (RFI).\u003c\/li\u003e\n  \u003cli\u003eUpewnij się, że ekranowanie jest uziemione zgodnie ze standardowymi schematami zakładu i systemu, zazwyczaj tylko na wspólnym uziemieniu szafy monitora.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668309963115,"sku":"3500\/61-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350061-01-00-xtkhixjynrt_181d4277-04bd-40cd-91af-57268dbb9a16.jpg?v=1765520814"},{"product_id":"bently-nevada-147663-01-3500-series-vga-display-i-o-module","title":"Moduł wejścia\/wyjścia wyświetlacza VGA Bently Nevada 147663-01 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojektowany do bezproblemowej integracji z systemami ochrony maszyn, \u003cstrong\u003e147663-01\u003c\/strong\u003e pełni funkcję dedykowanego interfejsu wejścia\/wyjścia wyświetlacza VGA w architekturze sterowania montowanej w szafie. Moduł ten umożliwia wizualizację w czasie rzeczywistym kluczowych parametrów maszyn, przesyłając przetworzone dane z czujników bezpośrednio do zewnętrznych monitorów wyświetlaczy.\u003c\/p\u003e\n\u003cp\u003eFunkcjonując jako kluczowy element ekosystemu monitorowania serii 3500, ten moduł I\/O wyświetlacza zapewnia transmisję wideo o wysokiej integralności bez kompromisów w szybkości przetwarzania tylnej płyty. Jego solidna konstrukcja jest przystosowana do pracy w wymagających warunkach przemysłowych, co czyni go odpowiednim do zastosowań w krytycznych systemach ochrony aktywów w różnych gałęziach przemysłu ciężkiego.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eZapewnia niezawodne trasowanie sygnału z szafy monitorującej do zewnętrznych ekranów wyświetlaczy.\u003c\/li\u003e\n  \u003cli\u003ePosiada porty o wysokiej gęstości zaprojektowane do okablowania przemysłowego.\u003c\/li\u003e\n  \u003cli\u003eZapewnia izolację tylnej płyty, chroniąc podstawowe funkcje monitorowania przed zewnętrznymi uszkodzeniami elektrycznymi po stronie wyświetlacza.\u003c\/li\u003e\n  \u003cli\u003eKompaktowa konstrukcja na jedno gniazdo optymalizuje przestrzeń w szafie systemowej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSystemy monitorowania maszyn turbomaśzynowych przemysłowych.\u003c\/li\u003e\n  \u003cli\u003eLokalne interfejsy wizualizacji w zakładach rafineryjnych ropy, gazu i petrochemii.\u003c\/li\u003e\n  \u003cli\u003eSystemy ochrony turbin i generatorów w elektrowniach.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProducent\u003c\/strong\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumer części\u003c\/strong\u003e\n      \u003ctd\u003e147663-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTyp modułu\u003c\/strong\u003e\n      \u003ctd\u003eModuł I\/O wyświetlacza VGA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eKompatybilność systemu\u003c\/strong\u003e\n      \u003ctd\u003eSystemy ochrony maszyn serii 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWaga wysyłkowa\u003c\/strong\u003e\n      \u003ctd\u003e2,0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTyp portu\u003c\/th\u003e\n      \u003cth\u003eFunkcja\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInterfejs VGA\u003c\/strong\u003e\n      \u003ctd\u003eWysyła sygnały wyświetlacza do zewnętrznych monitorów i terminali wizualnych.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eZłącze tylnej płyty szafy\u003c\/strong\u003e\n      \u003ctd\u003eZapewnia wymianę danych i zasilanie z obudowy monitorującej.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cp\u003eAby zapewnić bezpieczną i niezawodną pracę \u003cstrong\u003e147663-01\u003c\/strong\u003e, przestrzegaj następujących kroków instalacji:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eZawsze wyłączaj zasilanie szafy monitorującej przed włożeniem lub wyjęciem modułu I\/O, aby zapobiec przepięciom elektrycznym.\u003c\/li\u003e\n  \u003cli\u003eUpewnij się, że śruby obudowy modułu są całkowicie dokręcone, aby zapewnić solidne połączenie uziemienia z ramą szafy.\u003c\/li\u003e\n  \u003cli\u003eProwadź kable sygnałowe wyświetlacza z dala od linii silnika wysokiego napięcia, aby zapobiec zakłóceniom elektromagnetycznym zniekształcającym obraz wyświetlacza.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310061419,"sku":"147663-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/147663-01-xny1mknzqbt_aaf6d777-24e6-45b5-b877-d65d0195a76d.jpg?v=1765520817"},{"product_id":"bently-nevada-3500-61-05-00-3500-series-rtd-tc-non-isolated-i-o-module","title":"Moduł Wejścia\/Wyjścia Nieizolowany RTD\/TC Serii 3500 Bently Nevada 3500\/61-05-00","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojketowany do integracji w systemie ochrony maszyn 3500, \u003cstrong\u003eBently Nevada 3500\/61-05-00\u003c\/strong\u003e pełni funkcję specjalistycznego, nieizolowanego interfejsu wejścia\/wyjścia RTD\/TC z wewnętrznymi barierami bezpieczeństwa. Moduł ten współpracuje z monitorem temperatury 3500\/61, przetwarzając i kierując sygnały przetworników temperatury bezpośrednio z elementów maszyn do zewnętrznych systemów rejestracji, wykresów paskowych lub sterowników procesów.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e3500\/61-05-00\u003c\/strong\u003e Umożliwia niezawodną transmisję sygnału, dostarczając kondycjonowane wyjścia rejestratora odzwierciedlające mierzone wartości. Dzięki wbudowanym barierom ta konfiguracja sprzętowa stanowi zintegrowane rozwiązanie zabezpieczające połączenia okablowania polowego w środowiskach zagrożonych, bez konieczności stosowania dodatkowych zewnętrznych systemów barierowych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBezpośredni interfejs dla detektorów temperatury rezystancyjnej (RTD) i termopar (TC).\u003c\/li\u003e\n  \u003cli\u003eWewnętrzne bariery bezpieczeństwa zaprojektowane do ograniczania energii elektrycznej w strefach zagrożenia.\u003c\/li\u003e\n  \u003cli\u003eZapewnia ciągłe, proporcjonalne analogowe wyjścia rejestratora do rejestracji danych i analizy trendów.\u003c\/li\u003e\n  \u003cli\u003eKonfiguracja I\/O bez izolacji, zoptymalizowana pod kątem instalacji w gęstych, scentralizowanych szafach.\u003c\/li\u003e\n  \u003cli\u003eKompatybilny ze standardowymi szafami i płytami tylnej łączności serii 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMonitorowanie temperatury turbin parowych i gazowych.\u003c\/li\u003e\n  \u003cli\u003eOchrona uzwojeń dużych silników przemysłowych i generatorów.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie temperatury łożysk sprężarek i pomp.\u003c\/li\u003e\n  \u003cli\u003eInterfejsy do kontroli procesów petrochemicznych i rafineryjnych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProducent\u003c\/strong\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumer części \/ model\u003c\/strong\u003e\n      \u003ctd\u003e3500\/61-05-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeria\u003c\/strong\u003e\n      \u003ctd\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTyp modułu I\/O\u003c\/strong\u003e\n      \u003ctd\u003eModuł I\/O RTD\/TC bez izolacji z wewnętrznymi barierami\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOpcja zatwierdzenia agencji\u003c\/strong\u003e\n      \u003ctd\u003eBrak (Opcja 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWaga\u003c\/strong\u003e\n      \u003ctd\u003e0,91 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUpewnij się, że szafa systemu 3500 jest całkowicie wyłączona z zasilania przed instalacją lub demontażem modułu I\/O.\u003c\/li\u003e\n  \u003cli\u003eWłóż moduł 3500\/61-05-00 do tylnej części obudowy, dokładnie wyrównując go ze slotem karty monitorującej 3500\/61.\u003c\/li\u003e\n  \u003cli\u003eDokładnie dokręć śruby tylnej płyty, aby zabezpieczyć moduł i utrzymać prawidłowe uziemienie obudowy.\u003c\/li\u003e\n  \u003cli\u003eZweryfikuj impedancję pętli oraz limity elektryczne bariery przed podłączeniem okablowania polowego RTD lub TC.\u003c\/li\u003e\n  \u003cli\u003eProwadź kable czujników niskonapięciowych z dala od przewodów wysokoprądowych AC, aby zminimalizować zakłócenia elektromagnetyczne.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668312158571,"sku":"3500\/61-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350061-05-00-fsjtuqiluqx_b8e17e38-eef5-4988-a88a-22f12ff68c08.jpg?v=1765520885"},{"product_id":"bently-nevada-147364-01-3500-series-100base-fx-fiber-optic-i-o-module","title":"Moduł I\/O światłowodowy Bently Nevada 147364-01 serii 3500 100Base-FX","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUmożliwiając szybką i odporną na zakłócenia komunikację w szafie ochrony maszyn 3500, \u003cstrong\u003eBently Nevada 147364-01\u003c\/strong\u003e pełni rolę fizycznego interfejsu dla zewnętrznych połączeń Ethernet. Ten konkretny \u003cstrong\u003emoduł I\/O światłowodowy 100Base-FX\u003c\/strong\u003e montowany jest z tyłu szafy, bezpośrednio w linii z bramą komunikacyjną 3500\/92, przesyłając kluczowe dane diagnostyczne i monitorujące maszyny przez sieci optyczne. Zastępując tradycyjne połączenia miedziane światłowodem, zapewnia całkowitą izolację elektryczną i eliminuje problemy z pętlami masy w wymagających przemysłowych systemach telemetrycznych.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard 100Base-FX:\u003c\/strong\u003e Pracuje z prędkością 100 Mbps na wielomodowym światłowodzie.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePełna izolacja optyczna:\u003c\/strong\u003e Zapobiega zakłóceniom elektromagnetycznym (EMI) i radiowym (RFI), chroniąc integralność sygnału.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePodwójne złącza SC:\u003c\/strong\u003e Bezpośredni interfejs dla linii światłowodowych TX i RX, zapewniający solidne i niezawodne połączenia.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBezpośredni interfejs bramy:\u003c\/strong\u003e Montowany bezpośrednio z bramą 3500\/92, umożliwiający płynną komunikację Modbus\/TCP lub Ethernet własnościowy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrzemysłowa konstrukcja ciężka:\u003c\/strong\u003e Przystosowany do pracy w trudnych warunkach środowiskowych płyty tylnej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eWysokonapięciowe stacje rozdzielcze, gdzie sieci miedziane narażone są na zakłócenia indukcyjne.\u003c\/li\u003e\n  \u003cli\u003eInstalacje monitoringu maszyn na duże odległości do dwóch kilometrów bez wzmacniaczy sygnału.\u003c\/li\u003e\n  \u003cli\u003eZakłady petrochemiczne, naftowe i gazowe oraz elektrownie wymagające beziskrowych mediów transmisyjnych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecyfikacja\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumer części\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e147364-01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProtokół warstwy fizycznej\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100Base-FX (IEEE 802.3u)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMedium transmisyjne\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWielomodowe światłowody (62,5\/125 µm lub 50\/125 µm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZłącza interfejsu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePodwójne złącza SC (TX \/ RX)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDługość fali optycznej\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1300 nm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKompatybilny moduł bramy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBrama komunikacyjna 3500\/92\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres temperatur pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-30°C do +65°C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUSA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3,0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWymiary opakowania (obliczone)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e245 mm x 115 mm x 25 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eEtykieta portu\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunkcja \/ Specyfikacja połączenia\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTX\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePort nadajnika optycznego; wysyła sygnał świetlny 1300 nm wielomodowy do odbiornika przełącznika sieciowego.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRX\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePort odbiornika optycznego; odbiera sygnał świetlny 1300 nm z nadajnika przełącznika sieciowego.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eModele alternatywne i kompatybilność\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eModuł I\/O światłowodowy wielomodowy 147364-01 stanowi bezpośrednią alternatywę dla wariantów I\/O opartych na miedzi systemu 3500\/92, takich jak te wykorzystujące złącza RJ45 (np. 100Base-TX). Przechodząc z karty I\/O miedzianej na 147364-01, upewnij się, że twój moduł bramy 3500\/92 z przodu posiada oprogramowanie układowe zdolne do rozpoznawania interfejsów 100Base-FX, co zapobiega błędom konfiguracji w oprogramowaniu Bently Nevada 3500 Rack Configuration Software.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003ePułapki aplikacyjne i uwagi inżynieryjne\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eCzęstym błędem inżynieryjnym na miejscu jest próba połączenia tej karty wielomodowej z kablami światłowodowymi jednomodowymi (SM). Standardowe włókna jednomodowe mają znacznie węższe jądro i spowodują wysokie tłumienie optyczne, co prowadzi do awarii komunikacji lub przerywanych spadków Link\/Act. Aby używać tego modułu w infrastrukturze jednomodowej, musisz zintegrować zewnętrzny, przemysłowo wzmocniony konwerter mediów światłowodowych z wielomodowego na jednomodowy.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZawsze sprawdzaj mapowanie skrzyżowania RX i TX. Port TX w module 147364-01 musi być bezpośrednio połączony z portem RX sprzętu sieciowego i odwrotnie. Trzymaj nasadki przeciwkurzowe na portach SC aż do momentu gotowości fizycznych kabli do włożenia. Cząstki unoszące się w powietrzu, powszechne w środowiskach przemysłowych, mogą zanieczyścić wewnętrzną optyczną tuleję, co wymaga specjalistycznego czyszczenia suchą szmatką, aby przywrócić nominalne poziomy db.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-weight: bold;\"\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eNie wkładaj ani nie wyjmuj tylnego modułu I\/O, gdy zasilanie jest podłączone do systemu szafy 3500. Niekontrolowane przepięcia mogą powodować błędy tylnej płyty i uszkodzenia fizyczne wrażliwych układów optycznych nadajników i odbiorników. Uziem się do obudowy szafy za pomocą opaski ESD przed obsługą sprzętu.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eOdłącz zasilanie całej szafy 3500 i zweryfikuj to za pomocą skalibrowanego woltomierza.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eWyrównaj moduł z prowadnicami kart w slocie tylnej płyty bezpośrednio za odpowiadającą bramą komunikacyjną 3500\/92.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eDelikatnie wsuwaj moduł do przodu, aż złącza tylnej płyty zostaną całkowicie osadzone.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eDokładnie dokręć wkręty zatrzaskowe na przednim panelu modułu 147364-01, aby zapewnić uziemienie obudowy.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e5\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eZdejmij nasadki z konektorów światłowodowych SC i podłącz kable wielomodowe do portów.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668314255723,"sku":"147364-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/147364-01-twfqfncmzfm_0702e495-201b-4242-8094-fb49f6be460b.jpg?v=1765520959"},{"product_id":"bently-nevada-176449-01-125680-01-3500-40m-proximitor-monitor-and-i-o-module","title":"Moduł monitorujący i I\/O Bently Nevada 176449-01+125680-01 3500\/40M Proximitor","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eRealizując ciągłe funkcje ochrony maszyn w systemie szaf 3500, \u003cstrong\u003eBently Nevada 176449-01+125680-01\u003c\/strong\u003e łączy czterokanałowy monitor Proximitor 3500\/40M z modułem I\/O 125680-01 z wewnętrznymi zakończeniami. To połączenie przetwarza wysokoczęstotliwościowe sygnały z przetworników zbliżeniowych, zapewniając precyzyjne pomiary drgań promieniowych, pozycji nacisku, ekscentryczności i rozszerzalności różnicowej. Dzięki wbudowanym połączeniom zaciskowym bezpośrednio na karcie I\/O 125680-01, zestaw eliminuje potrzebę zewnętrznych listew zaciskowych, zmniejszając zajmowaną przestrzeń w szafie i upraszczając skomplikowane okablowanie w trudnych warunkach.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eArchitektura czterokanałowa:\u003c\/strong\u003e Niezależna konfiguracja kanałów umożliwia jednoczesne monitorowanie drgań promieniowych, osiowego nacisku i pozycji wału.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eWewnętrzne zakończenia:\u003c\/strong\u003e Karta tylna 125680-01 zawiera dedykowane bloki zakończeniowe bezpośrednio na module, upraszczając okablowanie pętli.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eWbudowane kondycjonowanie sygnału:\u003c\/strong\u003e Integruje wysokoprecyzyjną konwersję analogowo-cyfrową i dynamiczne przetwarzanie sygnału do obliczania wartości szczyt-szczyt i średnich.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eElastyczne profile alarmowe:\u003c\/strong\u003e Niezależna konfiguracja progów Alert i Niebezpieczeństwo dla każdego kanału z możliwością wyboru opóźnień czasowych.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eKompleksowa diagnostyka systemu:\u003c\/strong\u003e Ciągłe monitorowanie obwodów przetworników, zasilania i operacji wewnętrznych w celu natychmiastowego wyzwalania przejść stanu przekaźnika OK.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMonitorowanie drgań łożysk i pozycji wirnika turbin parowych i gazowych.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eAnaliza dynamiczna wirnika sprężarki odśrodkowej wysokiego ciśnienia.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMonitorowanie drgań przemysłowych przekładni, dmuchaw i wentylatorów ciężkich.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eOchrona krytycznych maszyn obrotowych w przemyśle naftowym, energetycznym i petrochemicznym.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eWartość specyfikacji\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumer części modułu monitorującego\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e176449-01 (3500\/40M)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumer części modułu I\/O\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e125680-01 (wewnętrzne zakończenia)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eKompatybilność systemu\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSystem monitorowania Bently Nevada 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eLiczba kanałów\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 niezależne kanały\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eObsługa przetworników wejściowych\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePrzetworniki Proximitor (w tym seria 3300 XL)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eZakres sygnału\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-24 VDC nominalne zasilanie pętli; standardowe wyjścia sondy zbliżeniowej\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTyp zakończenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eWewnętrzne listwy zaciskowe (zacisk śrubowy)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTemperatura pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-30 do +65 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStany Zjednoczone Ameryki (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWaga wysyłkowa\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e10,0 kg (łącznie z opakowaniem i modułami)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eEtykieta listwy zaciskowej\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003ePrzypisanie sygnału \/ Funkcja\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCh 1 PROX \/ COM \/ SIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eZasilanie przetwornika kanału 1, masa i powrót sygnału\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCh 2 PROX \/ COM \/ SIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eZasilanie przetwornika kanału 2, masa i powrót sygnału\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCh 3 PROX \/ COM \/ SIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eZasilanie przetwornika kanału 3, masa i powrót sygnału\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCh 4 PROX \/ COM \/ SIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eZasilanie przetwornika kanału 4, masa i powrót sygnału\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eZaciski SHLD\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTypowe punkty uziemienia ekranów instrumentów (izolowane od obudowy)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eModele alternatywne i kompatybilność\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eModuł I\/O 125680-01 wykorzystuje wewnętrzne zaciski śrubowe, co czyni go mechanicznym niekompatybilnym z szafami skonfigurowanymi do zewnętrznych bloków zakończeniowych (które używają innych wiązek kablowych i modułu I\/O 125680-02). Podczas gorącej wymiany lub wymiany starszych jednostek 3500\/40 upewnij się, że wersja oprogramowania układowego 176449-01 odpowiada wersji zaprogramowanej w oprogramowaniu konfiguracji szafy 3500, aby uniknąć błędów niedopasowania gniazda i stanów blokady modułu.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePonieważ wewnętrzne kable zakończeniowe podłączane są bezpośrednio do karty 125680-01 z tyłu szafy, na złącze tylnej płyty karty działa bezpośrednie naprężenie mechaniczne. Zastosuj solidne opaski kablowe i odciążenia w korytkach kablowych w panelu, aby odseparować ciężar zewnętrzny. Upewnij się, że całkowite obciążenie pętli zasilania przetwornika -24 VDC nie przekracza specyfikacji systemu przy użyciu niestandardowych kabli przedłużających lub niestandardowej długości przewodów czujników zbliżeniowych.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZawsze uziemiać ekrany kabli czujników na dedykowanych zaciskach SHLD w module 125680-01. Nigdy nie uziemiać ekranu na obu końcach, ponieważ powoduje to pętle masy, które zakłócają niskonapięciowe pomiary zbliżeniowe szumem przemysłowym 50\/60 Hz. Przed aktywnym uruchomieniem sprawdź, czy skonfigurowany współczynnik skali przetwornika (np. 7,87 V\/mm \/ 200 mV\/mil) dokładnie odpowiada skalibrowanemu współczynnikowi skali zainstalowanego czujnika Proximitor.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eOSTRZEŻENIE KRYTYCZNE: BEZPIECZEŃSTWO PRZEDE WSZYSTKIM\u003c\/strong\u003e\n  \u003cspan style=\"color: #9b2c2c;\"\u003eOdłącz zasilanie całego systemu szafy 3500 przed włożeniem lub wyjęciem karty I\/O 125680-01. Gorąca wymiana komponentów tylnej płyty pod obciążeniem grozi przejściowymi błędami elektrycznymi, które mogą wywołać fałszywe polecenia zatrzymania maszyny. Podczas instalacji uziem się za pomocą opaski ESD na nadgarstek.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWłóż moduł monitorujący 176449-01 do wybranego gniazda z przodu szafy 3500. Upewnij się, że zatrzaski wysuwu zablokowały się pewnie na miejscu.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWyrównaj wewnętrzny moduł zakończenia I\/O 125680-01 z pasującymi prowadnicami tylnego gniazda i mocno wciśnij, aż płytka całkowicie osadzi się w złączu tylnej płyty. Dokładnie dokręć tylne śruby motylkowe.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePodłącz przewody polowe do wewnętrznych zacisków śrubowych, zabezpieczając przewód ekranowania do wyznaczonego zacisku SHLD dla każdego odpowiedniego kanału.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWłącz zasilanie systemu, nawiąż połączenie z oprogramowaniem konfiguracji szafy 3500, załaduj odpowiedni profil gniazda i wykonaj test pętli na wszystkich aktywnych kanałach przetworników.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668314681707,"sku":"176449-01+125680-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/176449-01125680-01-i41d31qoc4g_a0c10ff9-b365-4890-8b40-c40c213b16c7.jpg?v=1765520974"},{"product_id":"bently-nevada-135489-02-i-o-module-with-internal-barriers-for-prox-accel-and-velomitor-signals","title":"Moduł I\/O Bently Nevada 135489-02 z wewnętrznymi barierami dla sygnałów Prox\/Accel i Velomitor","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e135489-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto moduł I\/O Bently Nevada zaprojektowany do bezpiecznego pozyskiwania sygnałów z czujników zbliżeniowych, przyspieszenia i prędkości w przemysłowych systemach monitorowania drgań. Integruje wewnętrzne bariery i zakończenia, co upraszcza architekturę okablowania, jednocześnie zachowując zgodność z wymogami bezpieczeństwa iskrobezpieczeństwa w instalacjach w strefach zagrożenia wybuchem. Moduł jest powszechnie stosowany w systemach ochrony turbin, sprężarek oraz krytycznych maszyn wirujących, gdzie wymagana jest niezawodna wielokanałowa analiza drgań do ciągłego monitorowania stanu.\u003c\/p\u003e\n\u003cp\u003eTen moduł I\/O obsługuje 2 kanały zbliżeniowe lub akcelerometryczne oraz 2 kanały Velomitor, umożliwiając konfiguracje mieszane czujników w jednym module. Jest szeroko wykorzystywany w zakładach naftowych i gazowych, elektrowniach oraz zakładach petrochemicznych, gdzie niezawodność systemu i zmniejszenie złożoności okablowania bezpośrednio wpływają na efektywność konserwacji i kontrolę przestojów.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 kanały Prox\/Accel do monitorowania drgań wału i przemieszczeń\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 kanały Velomitor do pomiaru prędkości drgań obudowy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWewnętrzne bariery do izolacji sygnałów zgodnej z iskrobezpieczeństwem\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWewnętrzne zakończenia upraszczające okablowanie szafy i zmniejszające złożoność instalacji\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWewnętrzna konstrukcja barier eliminuje potrzebę stosowania zewnętrznych izolatorów, co zmniejsza wymagania dotyczące przestrzeni w szafie i poprawia efektywność integracji systemu. Moduł zapewnia stabilne kondycjonowanie sygnału między czujnikami polowymi a systemami monitoringu, jednocześnie utrzymując ochronę elektryczną w środowiskach zagrożonych wybuchem.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParametr\u003c\/th\u003e\n\u003cth class=\"\"\u003eSzczegóły\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e135489-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarka\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp produktu\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z wewnętrznymi barierami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePochodzenie\u003c\/td\u003e\n\u003ctd\u003eWyprodukowano w USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKanały wejściowe\u003c\/td\u003e\n\u003ctd\u003e2 Prox\/Accel + 2 Velomitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp sygnału\u003c\/td\u003e\n\u003ctd\u003eWejścia drgań przemieszczenia i prędkości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunkcja bezpieczeństwa\u003c\/td\u003e\n\u003ctd\u003eWewnętrzne bariery iskrobezpieczeństwa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakończenie\u003c\/td\u003e\n\u003ctd\u003eWewnętrzne zakończenie sygnału\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZastosowanie\u003c\/td\u003e\n\u003ctd\u003eMonitorowanie turbin, sprężarek, pomp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eŚrodowisko pracy\u003c\/td\u003e\n\u003ctd\u003ePrzemysłowe strefy zagrożenia wybuchem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZużycie energii\u003c\/td\u003e\n\u003ctd\u003eZasilanie z szafy systemowej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga\u003c\/td\u003e\n\u003ctd\u003e0,201 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga wysyłkowa\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp instalacji\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O montowany w szynie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł może obsługiwać jednocześnie sygnały z czujników zbliżeniowych i prędkości?\u003c\/strong\u003e\u003cbr\u003eTak. Obsługuje 2 wejścia zbliżeniowe lub akcelerometryczne oraz 2 kanały prędkości Velomitor równocześnie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy moduł wymaga zewnętrznych barier sygnałowych?\u003c\/strong\u003e\u003cbr\u003eNie. Posiada wewnętrzne bariery, co zmniejsza ilość okablowania zewnętrznego i złożoność szafy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy jest kompatybilny z systemami monitoringu 3500?\u003c\/strong\u003e\u003cbr\u003eTak. Został zaprojektowany do integracji z architekturą systemów monitoringu Bently Nevada serii 3500.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo się stanie w przypadku awarii kanału?\u003c\/strong\u003e\u003cbr\u003eAwaria kanału wywoła alert diagnostyczny w systemie monitoringu, nie wpływając na pozostałe kanały.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstrukcja inżynieryjna i instalacyjna\u003c\/h3\u003e\n\u003cp\u003eZainstaluj moduł w odpowiednio uziemionej obudowie szafy, aby zachować integralność sygnału i zgodność z wymogami iskrobezpieczeństwa. Słabe uziemienie może wprowadzać szumy pomiarowe na wszystkich kanałach.\u003c\/p\u003e\n\u003cp\u003eOddziel okablowanie polowe od linii wysokiego napięcia i kabli VFD, aby uniknąć zakłóceń elektromagnetycznych, szczególnie w szafach sterowania turbin.\u003c\/p\u003e\n\u003cp\u003ePodczas uruchomienia zweryfikuj poprawną konfigurację kanałów. Nieprawidłowo skonfigurowane typy wejść (Prox\/Accel vs Velomitor) mogą prowadzić do błędnej interpretacji drgań.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321890667,"sku":"135489-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-02-i-o-module-with-internal-barriers-and-internal-terminations-ph4wmoxwykw_33e1082e-42c4-4eda-8942-5a692bc45121.jpg?v=1765449578"},{"product_id":"bently-nevada-3500-22m-01-01-00-transient-data-interface-with-ethernet-i-o","title":"Bently Nevada 3500\/22M-01-01-00 | Interfejs danych przejściowych z wejściami\/wyjściami Ethernet","description":"\u003ch3\u003ePrzegląd\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Transient Data Interface) to specjalistyczny procesor komunikacji i akwizycji danych dla systemu ochrony maszyn Bently Nevada serii 3500. W przeciwieństwie do standardowego 3500\/20 RIM, seria \"M\" TDI oferuje zaawansowane możliwości przechwytywania przebiegów i analizy danych przejściowych o wysokiej rozdzielczości. Ten moduł jest niezbędnym ogniwem pomiędzy wewnętrzną szyną racka a zewnętrznym oprogramowaniem diagnostycznym, takim jak System 1, umożliwiając monitorowanie w czasie rzeczywistym krytycznych maszyn obrotowych.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMarka:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eID modelu:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTyp sprzętu:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModuł i I\/O Transient Data Interface (TDI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKonfiguracja TDI:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpcja\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Standardowa – zaprojektowana do ogólnego monitorowania maszyn)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterfejs I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpcja\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Moduł I\/O Ethernet 10Base-T\/100Base-TX)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZatwierdzenie agencji:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpcja\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Brak \/ zastosowanie ogólne)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePołączenie Ethernet:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfejs miedziany RJ45 obsługujący 10\/100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCzęstotliwość odświeżania danych:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDane statyczne aktualizowane co 100 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePamięć:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWewnętrzna pamięć nieulotna do konfiguracji i rejestracji zdarzeń\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKraj pochodzenia:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWyprodukowano w USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWaga netto produktu:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1,11 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCałkowita waga wysyłkowa:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3,0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRola operacyjna i integracja\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ezajmuje pierwszą pozycję w racku 3500, obok zasilaczy. Nieustannie odczytuje dane ze wszystkich monitorów drgań, położenia i temperatury w racku. Wykorzystując interfejs Ethernet 10\/100, zapewnia przesyłanie dynamicznych przebiegów o dużej przepustowości bez opóźnień, co jest kluczowe dla wykrywania niestabilności wirnika lub zużycia łożysk podczas stanów przejściowych maszyny (rozruch, zatrzymanie lub zmiany prędkości).\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy 3500\/22M-01-01-00 jest kompatybilny ze starszymi rackami 3500?\u003c\/strong\u003eO: Tak, \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ezostał zaprojektowany tak, aby był kompatybilny wstecz z obudowami rack 3500, pod warunkiem, że szyna racka obsługuje architekturę TDI. Jest to zalecana aktualizacja dla starszych modułów 3500\/20.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy zatwierdzenie agencji \"00\" ogranicza wydajność modułu?\u003c\/strong\u003eO: Nie. Opcja \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoznacza, że jednostka nie posiada specyficznych certyfikatów do stref zagrożenia (takich jak CSA czy ATEX). Oferuje identyczną wydajność techniczną jak jednostki certyfikowane i jest idealna do pomieszczeń kontrolnych lub środowisk przemysłowych nieklasyfikowanych.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322742635,"sku":"3500\/22M-01-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350022m-01-01-00-dak4rp3gmkm_003a628d-19ea-4202-a869-d6aedfb09e6a.jpg?v=1765521208"},{"product_id":"abb-spfec12-symphony-plus-hr-i-o-analog-input-module","title":"Moduł wejścia analogowego ABB SPFEC12 Symphony Plus HR I\/O","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eABB \u003cstrong\u003eSPFEC12\u003c\/strong\u003e to moduł wejścia analogowego o wysokiej gęstości i rozdzielczości, zaprojektowany do akwizycji sygnałów procesowych w rozproszonych systemach sterowania Symphony Plus. Ten komponent sprzętowy przetwarza ciągłe sygnały polowe z nadajników, przekształcając zmienne analogowe w precyzyjne cyfrowe tablice danych dla procesora centralnego. Dzięki wbudowanej izolacji galwanicznej i natywnemu filtrowaniu sygnału na kanał, moduł izoluje magistralę sieci sterującej od wysokonapięciowych przejściowych zakłóceń polowych, minimalizując dryf pomiarowy w elektrycznie zakłóconych środowiskach przemysłowych.\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzetwarzanie sygnałów o wysokiej rozdzielczości:\u003c\/strong\u003e Konwertuje ciągłe prądy lub napięcia analogowe na bardzo szczegółowe wartości cyfrowe dla krytycznych pętli.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArchitektura S+ HR I\/O:\u003c\/strong\u003e W pełni kompatybilna z magistralą komunikacyjną płyty wejścia\/wyjścia Symphony Plus o wysokiej rozdzielczości.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIzolacja kanału:\u003c\/strong\u003e Chroni niskonapięciowe wewnętrzne obwody procesora przed zewnętrznymi pętlami uziemienia i wahaniami napięcia wspólnego.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eInterfejs z nadajnikami procesowymi 4-20mA monitorującymi ciśnienie, temperaturę i przepływ objętościowy.\u003c\/li\u003e\n\u003cli\u003eCiągły monitoring zmiennych wysokoczęstotliwościowych w procesach wytwarzania energii i uzdatniania ciężkiej wody.\u003c\/li\u003e\n\u003cli\u003eModernizacja starszych bloków wejściowych Harmony lub INFI 90 do wysokorozdzielczych rozproszonych systemów sterowania Symphony Plus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n\u003cth style=\"padding: 10px; font-weight: bold;\"\u003eParametr\u003c\/th\u003e\n\u003cth style=\"padding: 10px; font-weight: bold;\"\u003eWartość\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRodzina produktów\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eSymphony Plus (S+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumer modelu\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eSPFEC12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKlasa sprzętu\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eModuł wejścia analogowego o wysokiej rozdzielczości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e0,65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWymiary opakowania (obliczone)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e220 x 150 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n\u003cstrong\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e Odizoluj wszystkie zewnętrzne zasilacze pętli przyrządów polowych przed integracją modułu. Praca na aktywnych płytach wejścia\/wyjścia bez odpowiednich nadpisów procesowych może powodować sygnały przejściowe wywołujące nieoczekiwane wyłączenia systemów bezpieczeństwa lub sprzętu.\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eSprawdź kołki wyrównujące modułu tylnego i precyzyjnie umieść kartę w prowadnicach subracka Symphony Plus o wysokiej rozdzielczości.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eNaciśnij równomiernie i ciągle, aż przednia płyta karty całkowicie zatrzaśnie się w złączach tylnej płyty. Dokładnie dokręć śruby uziemiające, aby zapewnić ciągłość obudowy.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eZweryfikuj aktywny status diod LED na przednim panelu, aby potwierdzić, że konfiguracja wewnętrznego toru zasilania i łącze komunikacyjne są stabilne.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668496249195,"sku":"SPFEC12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-spfec12-analog-input-module-bikrzikfpsj_0d213da1-759e-4e11-a093-88bd75d57500.jpg?v=1765532355"},{"product_id":"abb-ndio-02-option-sp-kit-rep58976059-digital-i-o-extension","title":"ABB NDIO-02 ZESTAW OPCJI\/SP REP58976059 Cyfrowe rozszerzenie wejść\/wyjść","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNDIO-02 OPTION\/SP KIT\u003c\/strong\u003e (ID produktu: \u003cstrong\u003eREP58976059\u003c\/strong\u003e) to zestaw rozszerzeń cyfrowych wejść\/wyjść zaprojektowany dla niskonapięciowych przemysłowych napędów AC. Ta opcjonalna płytka rozszerzeń zapewnia dodatkową pojemność cyfrowych wejść i wyjść bezpośrednio w strukturze sterownika napędu, umożliwiając szerszy monitoring automatyki peryferyjnej, pozyskiwanie informacji zwrotnych oraz koordynację zewnętrznych pętli procesowych. Opracowany jako zintegrowany moduł, zachowuje pełną kompatybilność sygnałową z wewnętrzną architekturą starszych napędów, szczególnie współpracując z systemami wielonapędowymi, takimi jak seria ACS600 Multidrives.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRozszerzona pojemność interfejsu\u003c\/strong\u003e: Zwiększa lokalne możliwości sterowania poprzez dodanie niezależnych cyfrowych kanałów do struktury przetwarzania.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpośrednia integracja z napędem\u003c\/strong\u003e: Montowany w dedykowanych gniazdach płytek opcji wewnętrznych, bez konieczności zajmowania dodatkowej przestrzeni montażowej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtrzymanie starszych podsystemów\u003c\/strong\u003e: Służy jako standardowa certyfikowana część naprawcza, przedłużająca eksploatację istniejących przemysłowych systemów wielonapędowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracje ACS600 Multidrives\u003c\/strong\u003e: Pełni rolę dedykowanego rozszerzenia sprzętowego w chłodzonych wodą układach ACW610.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegracja niskonapięciowych napędów AC\u003c\/strong\u003e: Stosowany w starszych szafach napędów o zmiennej prędkości wymagających dyskretnej skalowalności sygnałów.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfejsowanie automatyki procesowej\u003c\/strong\u003e: Używany do prowadzenia zdalnych wyłączników krańcowych, blokad oraz cyfrowych wskaźników stanu pracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWartość\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNDIO-02 OPTION\/SP KIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eID produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eREP58976059\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNazwa produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIGITAL I\/O EXTEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCzęść naprawcza \/ zamienna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKompatybilność systemu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eACS600 Multidrives chłodzone wodą (ACW610)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSzwecja (SE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer taryfy celnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85049099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga netto produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary (S x W x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 mm x 95 mm x 30 mm (szacowane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOdizoluj wszystkie główne linie zasilania AC oraz obwody wysokiego napięcia od zespołu szafy przed przystąpieniem do serwisu.\u003c\/li\u003e\n\u003cli\u003ePozwól, aby wewnętrzne kondensatory pośredniego obwodu DC napędu rozładowały się całkowicie zgodnie z harmonogramem bezpieczeństwa głównego urządzenia.\u003c\/li\u003e\n\u003cli\u003eMocno zamontuj modułową płytkę opcji w przypisanym gnieździe ramy jednostki sterującej, aby zapewnić solidną integralność ścieżki uziemienia elektrycznego przez punkty mocujące.\u003c\/li\u003e\n\u003cli\u003eStarannie przymocuj okablowanie interfejsu sygnałowego do listw zaciskowych, oddzielając przewody logiczne od sąsiednich linii zasilania wysokiego napięcia, aby zmniejszyć ryzyko zakłóceń elektromagnetycznych.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668497166699,"sku":"NDIO-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-ndio-02-64129007-digital-i-o-extension-module-4odpuvdg3ts_dbb1f0ca-3a7f-4b1d-8f3f-d518b9e6c100.jpg?v=1765532441"}],"url":"https:\/\/www.plcprotech.com\/pl\/collections\/i-o-modules.oembed?page=3","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}