{"title":"Lenze","description":"\u003cp\u003eLenze delivers high-performance drive and automation technology designed for motion control and energy efficiency. This collection features the modular i500 series (i510, i550) frequency inverters, the versatile 8400 series (StateLine, HighLine, TopLine), and the high-precision 9400 HighLine servo drives. Whether you are replacing E82EV legacy units or upgrading to the latest m550 motors and c300 controllers, our selection provides the reliable hardware and specialized modules needed for sophisticated machine tasks and optimized power transmission.\u003c\/p\u003e","products":[{"product_id":"lenze-evf8243-e-8200-series-ac-drive","title":"Lenze EVF8243-E 8200-series AC Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDesigned for precise speed and torque control of three-phase asynchronous motors, the Lenze EVF8243-E frequency inverter integrates seamlessly into centralized control cabinet architectures. This robust \u003cstrong\u003e2HP (1.5 kW)\u003c\/strong\u003e drive operates on a \u003cstrong\u003e460V\u003c\/strong\u003e nominal supply, delivering reliable dynamic performance in demanding industrial environments. As part of the legacy \u003cstrong\u003e8200-series\u003c\/strong\u003e modular frequency inverter range, it features a compact footprint and flexible communication options via pluggable function modules.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eModular design supporting plug-in fieldbus and I\/O modules.\u003c\/li\u003e\n  \u003cli\u003eVector control capability for high dynamic torque response.\u003c\/li\u003e\n  \u003cli\u003eIntegrated motor overload protection and thermal monitoring.\u003c\/li\u003e\n  \u003cli\u003eCompact IP20 enclosure design optimized for space-saving side-by-side mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eConveyor systems and material handling lines.\u003c\/li\u003e\n  \u003cli\u003eIndustrial pumps, fans, and ventilation systems.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and automated assembly lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border-bottom: 2px solid #2b6cb0; text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"border-bottom: 2px solid #2b6cb0; text-align: left; padding: 8px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eEVF8243-E\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eType Code\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003e33.8243_E\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003e8200-series\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border-bottom: 2px solid #2b6cb0; text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border-bottom: 2px solid #2b6cb0; text-align: left; padding: 8px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eEVF8243-E\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003ePower Rating\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003e1.5 kW (2 HP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003e400 V \/ 460 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003ePhase\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003e3-Phase\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eEnclosure Rating\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003ePhase-Out (Legacy support available)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eDimensions\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003e10.20 x 35.60 x 25.40 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003e5.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe EVF8243-E belongs to the legacy 8200 Vector family. For modern retrofits, the Lenze i550 series or 8400 StateLine drives are the recommended migration paths, though parameter conversion is required as register maps differ.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen operating in high ambient temperatures (above 40 degC), derating of the continuous output current is mandatory. Ensure adequate clearance at the top and bottom of the drive (minimum 100 mm) to prevent thermal tripping under continuous heavy loads.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nParameterization requires either the EMZ8201BB keypad module or the LECOM communication module connected to a PC running Global Drive Control (GDC) software. Always use shielded motor cables with 360-degree EMC grounding clamps to prevent high-frequency interference with nearby analog sensor signals.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    DANGER: HAZARD OF ELECTRIC SHOCK OR ARC FLASH. Disconnect all power sources before servicing the drive. Wait at least 5 minutes after de-energizing to allow internal DC bus capacitors to discharge to safe voltage levels (\u0026lt; 50 VDC) before touching any electrical terminals.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the drive vertically on a flat, vibration-free metal backplane to ensure optimal heat dissipation.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the protective earth (PE) conductor to the central ground terminal before making any other electrical connections.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the 3-phase AC mains supply to terminals L1, L2, and L3, and the motor leads to U, V, and W.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInstall the required control module or keypad into the front-panel slot and configure the motor nameplate parameters.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105046684011,"sku":"EVF8243-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evf8243-e-1qohttxsqd1.png?v=1776236440"},{"product_id":"lenze-e84avsce1524sx0-8400-series-variable-frequency-drive","title":"Lenze E84AVSCE1524SX0 8400 Series Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for precise speed and torque control in automated machinery, the \u003cstrong\u003eLenze E84AVSCE1524SX0\u003c\/strong\u003e variable frequency drive delivers reliable motor regulation within the 8400 StateLine series. This high-performance \u003cstrong\u003einverter drive\u003c\/strong\u003e is designed for control cabinet installation, featuring integrated interference suppression (EMC filter) to ensure stable operation even in electrically noisy industrial environments. Operating on a 3-phase 400\/500 V mains supply, it provides a rated power output of 1.5 kW, making it highly suitable for material handling, packaging systems, and general machine automation.\u003c\/p\u003e\n\n\u003cp\u003eThe robust electronic design of the \u003cstrong\u003eE84AVSCE1524SX0\u003c\/strong\u003e ensures long-term durability and energy-efficient motor control. Its modular architecture allows for seamless integration into existing industrial networks, supporting standard commissioning tools and diagnostics common to the Lenze 8400 product family.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated radio interference suppression (EMC filter) for reduced electromagnetic emissions.\u003c\/li\u003e\n  \u003cli\u003eDesigned for stable operation on 3-phase 400 V to 500 V AC mains.\u003c\/li\u003e\n  \u003cli\u003eDelivers a continuous rated power output of 1.5 kW.\u003c\/li\u003e\n  \u003cli\u003eCompact control cabinet mounting design to optimize panel space.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Lenze 8400 series software tools for simplified parameterization and diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConveyor systems and material handling lines.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and labeling systems.\u003c\/li\u003e\n  \u003cli\u003eIndustrial pumps, fans, and ventilation control.\u003c\/li\u003e\n  \u003cli\u003eGeneral machine tool and production line automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE84AVSCE1524SX0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8400 StateLine \/ 8400 Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVariable Frequency Drive (Inverter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMains Voltage Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 x 400 V \/ 500 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Power Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInterference Suppression\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated EMC Filter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl Cabinet Mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24.00 cm x 14.00 cm x 6.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.40 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Install the drive vertically inside the control cabinet to ensure optimal heat dissipation and natural convection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain the manufacturer-specified minimum clearances above and below the unit for adequate ventilation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure a low-impedance connection to the central PE ground busbar of the control cabinet to guarantee proper EMC filter performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Use shielded motor cables and keep control wiring separated from high-power mains and motor cables to prevent cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047372139,"sku":"E84AVSCE1524SX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e84avsce1524sx0-yz3vyzvr5fz.png?v=1776236098"},{"product_id":"lenze-e94aym44-9400-series-memory-module","title":"Lenze E94AYM44 9400-series Memory Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eParameter management and device commissioning within the 9400 servo drive system are streamlined using the \u003cstrong\u003eLenze E94AYM44\u003c\/strong\u003e memory module (MM440). This plug-in hardware utility serves as the central storage medium for drive configurations, application programs, and motor parameters. Engineered specifically for the \u003cstrong\u003eLenze 9400\u003c\/strong\u003e HighLine and StateLine servo positioning controllers, the MM440 memory module enables rapid device replacement and firmware management without requiring external PC software or specialized programming tools. By archiving the exact operational state of the controller, this module ensures high system availability and simplifies maintenance workflows in automated industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStores complete drive configuration, firmware, and user application parameters.\u003c\/li\u003e\n  \u003cli\u003eEnables plug-and-play drive replacement to minimize system downtime.\u003c\/li\u003e\n  \u003cli\u003eEnsures reliable data retention without the need for an internal backup battery.\u003c\/li\u003e\n  \u003cli\u003eDesigned for direct integration into the dedicated memory slot of Lenze 9400 drive controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eServo drive configuration backup and duplication across multi-axis systems.\u003c\/li\u003e\n  \u003cli\u003eAutomated machinery commissioning in packaging, material handling, and textile production.\u003c\/li\u003e\n  \u003cli\u003eField service and rapid component replacement in high-duty industrial production lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE94AYM44 (MM440)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9400 HighLine \/ StateLine\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMemory Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Retention\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNon-volatile flash memory\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze 9400 Series Servo Drives\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047437675,"sku":"E94AYM44","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e94aym44-iikikuheirh.png?v=1776236216"},{"product_id":"lenze-evs9326-ei-9300-series-servo-drive","title":"Lenze EVS9326-EI 9300-Series Servo Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for high-performance motion control within coordinated multi-axis systems, the \u003cstrong\u003eLenze EVS9326-EI\u003c\/strong\u003e operates as a closed-loop servo inverter within the legacy \u003cstrong\u003e9300-Series\u003c\/strong\u003e family. This unit delivers precise speed, torque, and position control for demanding industrial automation architectures, providing a rated power output of \u003cstrong\u003e11.0 kW\u003c\/strong\u003e in a robust, cabinet-mounted form factor.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIntegrated system bus (CAN) for seamless multi-drive synchronization.\u003c\/li\u003e\n  \u003cli\u003eHigh overload capacity for dynamic acceleration and deceleration phases.\u003c\/li\u003e\n  \u003cli\u003eIP20 protection rating designed for clean, dry control cabinet environments.\u003c\/li\u003e\n  \u003cli\u003eFlexible feedback interface supporting resolvers and incremental encoders.\u003c\/li\u003e\n  \u003cli\u003eComprehensive diagnostics and parameterization via Global Drive Control (GDC) software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003ePackaging machinery and continuous material handling lines.\u003c\/li\u003e\n  \u003cli\u003eGantry robots, positioning axes, and pick-and-place systems.\u003c\/li\u003e\n  \u003cli\u003eRotary indexing tables and synchronized electronic gearboxes.\u003c\/li\u003e\n  \u003cli\u003eTextile manufacturing and printing press tension control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #cbd5e0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border: 1px solid #cbd5e0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border: 1px solid #cbd5e0;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eEVS9326-EI\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003e9300-Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eServo Drive \/ Controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eRated Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003e11.0 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eEnclosure Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003ePhase-Out (Legacy Spare Part)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eExport Control Classification (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003e35.00 x 25.00 x 13.50 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003e7.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #cbd5e0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border: 1px solid #cbd5e0;\"\u003eTerminal \/ Connector\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border: 1px solid #cbd5e0;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eX1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eMains Input Connection \/ DC Bus Link\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eX2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eMotor Phase Output \u0026amp; Motor Temperature Sensor (PTC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eX3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eResolver Feedback Input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eX4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eIncremental Encoder Input \/ Master-Slave Interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eX5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eAnalog and Digital Control Inputs\/Outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0; font-weight: bold;\"\u003eX6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border: 1px solid #cbd5e0;\"\u003eSystem Bus (CAN) Interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \"EI\" suffix designates this unit as the standard execution featuring incremental encoder input\/output capabilities. It can directly replace older EVS9326-ES units in most applications, provided the parameter set is migrated and verified using Lenze Global Drive Control (GDC) software. Ensure that the firmware version of the replacement unit matches or exceeds the original to prevent fieldbus mapping mismatches.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this drive is IP20 rated, it must be installed in a clean, dust-free control cabinet. At 11.0 kW continuous output, thermal dissipation is significant. Maintain a minimum vertical clearance of 100 mm above and below the unit to prevent localized overheating. For high-inertia applications, an external braking resistor must be connected to terminals UG+ and BR to prevent overvoltage trips (fault code OU) during rapid deceleration.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use double-shielded, twisted-pair cabling for the resolver (X3) and encoder (X4) feedback loops. Ground the cable shields at both ends using low-impedance EMC shield clamps to prevent high-frequency noise from corrupting the feedback signal. When integrating the drive into a CAN network via X6, ensure a 120-ohm terminating resistor is physically installed at both ends of the bus line.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all input power sources (mains and 24 VDC auxiliary control power) before performing installation or maintenance. Wait at least 5 minutes after power-off to allow the internal DC bus capacitors to fully discharge below 60 VDC. Verify the absence of voltage with a calibrated multimeter at the DC bus terminals before handling.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the drive vertically on a flat, conductive, and grounded backplate inside the control cabinet to ensure optimal heat transfer and EMC grounding.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the protective earth (PE) conductor directly to the drive's grounding terminal before making any other electrical connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the mains input power to terminal X1 and the motor phases to terminal X2 using shielded motor cables to minimize electromagnetic radiation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the resolver or encoder feedback cable to the respective port (X3 or X4) and route control signals away from high-power cabling.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047503211,"sku":"EVS9326-EI","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9326-ei-prxqfxbndbd.png?v=1776236672"},{"product_id":"lenze-e94amhe0074-9400-series-servo-drive","title":"Lenze E94AMHE0074 9400-series Servo Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOptimized for centralized multi-axis systems, the \u003cstrong\u003eLenze E94AMHE0074\u003c\/strong\u003e serves as a high-performance servo drive within the \u003cstrong\u003e9400-series\u003c\/strong\u003e portfolio. This multi-drive module is engineered to deliver precise motion control and dynamic response in demanding industrial environments. Operating on a common DC bus system, it utilizes a wide DC supply voltage range to maximize energy efficiency and facilitate power sharing between motoring and regenerating drives.\u003c\/p\u003e\n\n\u003cp\u003eThe modular design of the \u003cstrong\u003eE94AMHE0074\u003c\/strong\u003e allows for seamless integration of optional communication modules, enabling compatibility with standard industrial networks such as Ethernet, Powerlink, and Profibus. This flexibility ensures straightforward adaptation to diverse control architectures and distributed automation topologies.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for multi-drive configurations with shared DC bus systems.\u003c\/li\u003e\n  \u003cli\u003eWide DC input voltage range supporting flexible power distribution.\u003c\/li\u003e\n  \u003cli\u003eModular slot architecture for optional fieldbus communication interfaces.\u003c\/li\u003e\n  \u003cli\u003eHigh dynamic performance tailored for precise speed and position control.\u003c\/li\u003e\n  \u003cli\u003eCompact mechanical footprint to optimize control cabinet space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMulti-axis packaging and converting machinery.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems and gantry cranes.\u003c\/li\u003e\n  \u003cli\u003eTextile manufacturing and processing lines.\u003c\/li\u003e\n  \u003cli\u003ePrinting and paper processing machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE94AMHE0074\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9400-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eServo Drive (Multi Drive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Supply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e260 to 775 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Voltage (VN)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e565 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35.00 x 9.70 x 25.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.30 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure reliable operation and compliance with thermal limits, the following installation practices must be observed:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Install the drive vertically within the electrical enclosure to facilitate natural convection and optimal airflow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e Maintain the manufacturer-specified minimum clearances above and below the unit for adequate ventilation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Bus Connection:\u003c\/strong\u003e Ensure correct polarity when connecting to the common DC bus. Use appropriate fusing and busbar connections designed for multi-axis configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Implement low-impedance HF grounding. Motor cables must be shielded, with the shield grounded at both ends to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047568747,"sku":"E94AMHE0074","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e94amhe0074-ozjz15hdli0.png?v=1776236112"},{"product_id":"lenze-e82zafpc010-8200-series-communication-module","title":"Lenze E82ZAFPC010 8200-series Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegration of frequency inverters into centralized fieldbus networks is simplified using the \u003cstrong\u003eE82ZAFPC010\u003c\/strong\u003e PROFIBUS DP communication function module. Engineered specifically for the Lenze \u003cstrong\u003e8200-series\u003c\/strong\u003e frequency inverters, this pluggable interface module enables high-speed cyclic data exchange between a master PLC or host controller and the drive system. By establishing a reliable digital communication link, the module allows for precise control, parameterization, and real-time diagnostics of the connected drive, reducing wiring complexity and improving overall system response times.\u003c\/p\u003e\n\n\u003cp\u003eThis communication module mounts directly onto the front interface slot of the inverter, drawing its control power directly from the host drive. It supports standard PROFIBUS DP transmission rates and integrates seamlessly into existing industrial control architectures, making it a critical component for maintaining or upgrading legacy automation networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for seamless mechanical and electrical integration with Lenze 8200-series vector inverters.\u003c\/li\u003e\n  \u003cli\u003eSupports standard PROFIBUS DP communication protocol for high-speed cyclic data transfer.\u003c\/li\u003e\n  \u003cli\u003ePluggable architecture allows for rapid installation, configuration, and field replacement.\u003c\/li\u003e\n  \u003cli\u003eDirect bus connection reduces hardwired control lines and simplifies diagnostic troubleshooting.\u003c\/li\u003e\n  \u003cli\u003ePowered directly via the drive's internal interface slot, eliminating the need for external auxiliary power supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFactory automation and centralized machine control networks.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and material handling applications requiring synchronized drive control.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and production lines integrated via PROFIBUS DP networks.\u003c\/li\u003e\n  \u003cli\u003eWater treatment and HVAC systems utilizing distributed drive architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eParameter\u003c\/strong\u003e\n      \u003cstrong\u003eValue\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003eE82ZAFPC010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003e8200-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eCommunication Function Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Phase\u003c\/td\u003e\n      \u003ctd\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.10 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e5.10 cm x 7.60 cm x 2.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure safe and reliable operation, adhere to the following installation procedures:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Disconnect all electrical power from the frequency inverter and wait for the internal DC-bus capacitors to fully discharge before mounting or removing the communication module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Carefully align the module's connector pins with the interface slot on the front of the 8200-series inverter. Press firmly until the module is fully seated, and secure any integrated retaining screws to ensure solid grounding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Use only approved, high-quality shielded twisted-pair cables specified for PROFIBUS DP networks. Ensure the cable shield is grounded at both ends to prevent electromagnetic interference (EMI) from disrupting data transmission.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e Ensure that proper bus termination resistors are activated or installed at the first and last physical nodes of the PROFIBUS network segment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047667051,"sku":"E82ZAFPC010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafpc010-1ydszdbcdu1.png?v=1776236004"},{"product_id":"lenze-e82zafsc-8200-series-analog-i-o-function-module","title":"Lenze E82ZAFSC 8200-series Analog I\/O Function Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned to expand the control capabilities of Lenze 8200 vector frequency inverters, the \u003cstrong\u003eE82ZAFSC\u003c\/strong\u003e function module provides a versatile interface for analog and digital control signals. This plug-in module mounts directly onto the inverter's front interface slot, enabling seamless integration with external sensors, PLCs, and actuators. By supporting both analog and digital I\/O channels, it facilitates precise speed control, status monitoring, and system integration without requiring external signal converters.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eE82ZAFSC\u003c\/strong\u003e is engineered for high reliability in demanding industrial environments, ensuring stable signal transmission and robust noise immunity. It serves as a cost-effective expansion option for legacy automation setups utilizing the 8200 vector drive series, maintaining operational efficiency and system longevity.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect plug-in installation on the front interface slot of Lenze 8200 vector frequency inverters.\u003c\/li\u003e\n  \u003cli\u003eEquipped with 1 analog input configurable for voltage or current signals.\u003c\/li\u003e\n  \u003cli\u003eProvides 1 analog output (0 to 10 V) for feedback or monitoring.\u003c\/li\u003e\n  \u003cli\u003eFeatures 4 digital inputs for control commands such as start\/stop, direction, and preset speeds.\u003c\/li\u003e\n  \u003cli\u003eIncludes 1 digital output for status signaling and fault reporting.\u003c\/li\u003e\n  \u003cli\u003eInternal power supply drawn directly from the host inverter's interface slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSpeed and torque control in conveyor systems and material handling.\u003c\/li\u003e\n  \u003cli\u003eIntegration of pressure, flow, and temperature sensors in pump and fan applications.\u003c\/li\u003e\n  \u003cli\u003eGeneral industrial automation and machine control using Lenze 8200 vector drives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eParameter\u003c\/strong\u003e\n      \u003cstrong\u003eValue\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003eE82ZAFSC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003e8200-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eStandard I\/O Function Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n      \u003ctd\u003e1 (0 to 10 V, 0 to 20 mA, 4 to 20 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n      \u003ctd\u003e1 (0 to 10 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 (PLC level, HTL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Outputs\u003c\/td\u003e\n      \u003ctd\u003e1 (PLC level, HTL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e5.10 x 7.60 x 2.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.05 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Designation\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1U\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input (0 to 10 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1I\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input (0 to 20 mA or 4 to 20 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2U\u003c\/td\u003e\n      \u003ctd\u003eAnalog Output (0 to 10 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE1\u003c\/td\u003e\n      \u003ctd\u003eDigital Input 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE2\u003c\/td\u003e\n      \u003ctd\u003eDigital Input 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE3\u003c\/td\u003e\n      \u003ctd\u003eDigital Input 3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE4\u003c\/td\u003e\n      \u003ctd\u003eDigital Input 4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA1\u003c\/td\u003e\n      \u003ctd\u003eDigital Output 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGND\u003c\/td\u003e\n      \u003ctd\u003eReference Ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the host inverter is completely powered down and the DC bus capacitors are fully discharged before inserting or removing the module.\u003c\/li\u003e\n  \u003cli\u003ePlug the E82ZAFSC module firmly into the designated slot on the front of the 8200 vector inverter.\u003c\/li\u003e\n  \u003cli\u003eSecure the module using the integrated retaining screws to ensure reliable grounding and mechanical stability.\u003c\/li\u003e\n  \u003cli\u003eRoute analog signal cables separately from high-voltage motor and power lines to prevent electromagnetic interference. Use shielded cables for all analog connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047732587,"sku":"E82ZAFSC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafsc-2trqe2yiywt.png?v=1776236025"},{"product_id":"lenze-evs9323-ep-9300-series-servo-position-controller","title":"Lenze EVS9323-EP 9300-Series Servo Position Controller","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for precise motion control and dynamic positioning tasks in automated industrial environments, the Lenze EVS9323-EP serves as a high-performance servo position controller within the 9300-Series family. This unit integrates seamlessly into centralized or decentralized control architectures, providing robust closed-loop control for synchronous and asynchronous AC servo motors. Engineered with an IP20 protection rating, it is optimized for vertical installation within protected electrical control cabinets, ensuring reliable thermal management and long-term operational stability in demanding manufacturing processes.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Positioning Control:\u003c\/strong\u003e Built-in profile generators and position registers support complex motion profiles, homing runs, and target-positioning sequences without requiring external high-speed PLC modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Bus Interface:\u003c\/strong\u003e Native CAN system bus integration enables high-speed communication between multiple drives, controllers, and supervisory HMI systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Feedback Support:\u003c\/strong\u003e Compatible with standard resolver systems and high-resolution encoders for precise speed and position feedback.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Designed for vertical mounting with optimized heatsink geometry to facilitate efficient natural or forced convection cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Expansion:\u003c\/strong\u003e Supports pluggable communication modules (AIF) for integration into PROFIBUS, Interbus, or other industrial fieldbus networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e High-speed indexing, rotary cutters, and electronic gearing systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Automated storage and retrieval systems (ASRS), gantry cranes, and high-speed transfer carriages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAssembly \u0026amp; Robotics:\u003c\/strong\u003e Multi-axis pick-and-place systems, Cartesian robots, and precise rotary indexing tables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTextile Processing:\u003c\/strong\u003e Tension-controlled winding, unwinding, and synchronized feed-axis control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eEVS9323-EP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9300-Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDevice Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eServo Position Controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Power Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.5 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDegree of Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e10.20 cm x 35.60 cm x 25.40 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4.90 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eExport Control Classification (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eX1\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAnalog inputs and outputs (speed\/torque setpoints, monitoring)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eX2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDigital inputs and outputs (start, stop, limit switches, ready status)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eX4\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCAN system bus (system bus connection, synchronization)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eX11\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eResolver input (motor feedback connection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAIF Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAutomation Interface for pluggable communication modules (e.g., PROFIBUS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe EVS9323-EP is specifically configured as a position controller. It should not be confused with the EVS9323-ES (speed controller variant) or the EVF9323 (frequency inverter). When replacing older hardware revisions, verify that the firmware version of the replacement unit matches or exceeds the original to ensure compatibility with existing Global Drive Control (GDC) parameter sets and fieldbus configurations.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIn applications involving rapid deceleration cycles or high-inertia loads, the internal DC-bus capacitance may be insufficient to absorb regenerative energy. To prevent overvoltage faults (typically indicated by fault code OU), an external brake resistor must be sized and connected across the appropriate power terminals. Ensure adequate clearance of at least 100 mm above and below the drive inside the cabinet to prevent thermal accumulation.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use double-shielded twisted-pair cabling for the resolver feedback (X11) and CAN system bus (X4) interfaces. The shield must be grounded with low-impedance connections directly to the mounting plate using grounding clamps. Avoid routing control and feedback cables parallel to high-voltage motor power cables to mitigate electromagnetic interference (EMI) issues.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Ensure complete physical de-energization of the mains supply before handling. The DC-bus capacitors retain lethal voltages (up to 800V DC) after power-off. Wait a minimum of 5 minutes for residual charge to bleed down to safe levels (\u0026lt; 50V DC) before initiating any wiring, terminal connection, or inspection procedures. Verify with a calibrated multimeter.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the controller vertically on a flat, vibration-free backplate inside an IP54 or higher rated control cabinet to maintain the IP20 protection rating.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the protective earth (PE) conductor to the designated grounding terminal before making any other electrical connections.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the motor power terminals (U, V, W) and feedback resolver (X11) using shielded cables, ensuring proper shield termination at the drive's grounding plate.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eComplete control wiring (X1, X2) and configure the CAN bus network termination resistors (120 Ohm) if the unit is positioned at the physical end of the network segment.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047798123,"sku":"EVS9323-EP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9323-ep-bj0op513kbq.png?v=1776236568"},{"product_id":"lenze-e82ev751-2b-8200-series-variable-frequency-drive","title":"Lenze E82EV751_2B 8200 Series Variable Frequency Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding precise speed and torque regulation for industrial three-phase AC induction motors, the \u003cstrong\u003eLenze E82EV751_2B\u003c\/strong\u003e serves as a reliable vector-controlled variable frequency drive within the legacy \u003cstrong\u003e8200 Vector\u003c\/strong\u003e series. This compact drive module is engineered for space-saving control cabinet installation, delivering robust performance in demanding automation architectures. It supports both single-phase and three-phase mains connections, making it highly adaptable to various field power configurations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Input Configuration:\u003c\/strong\u003e Supports 1-phase or 3-phase AC 230\/240 V input voltages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Output:\u003c\/strong\u003e Delivers an adjustable output frequency from 0 to 650 Hz, ideal for high-speed spindle operations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Communication:\u003c\/strong\u003e Equipped with an integrated slot for pluggable fieldbus modules (CAN, PROFIBUS, or LECOM).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Protection:\u003c\/strong\u003e Built-in motor overload, short-circuit, earth-fault, and overvoltage monitoring circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Optimized footprint designed for space-restricted control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eConveyor and material handling systems requiring controlled acceleration and deceleration.\u003c\/li\u003e\n  \u003cli\u003eIndustrial pumps, fans, and ventilation systems.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and automated assembly lines.\u003c\/li\u003e\n  \u003cli\u003eMachine tool auxiliary drives and high-speed spindle applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eE82EV751_2B (E82EV751K2B)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8200 Vector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Voltage Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1(3)\/PE AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e230 \/ 240 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e9.0 A (1-phase) \/ 5.2 A (3-phase)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Voltage Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3\/PE AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 230 \/ 240 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4.0 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Power Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.75 kW (1.0 HP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Frequency Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 650 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePhase-Out (Legacy)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24.0 x 16.2 x 30.6 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.74 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.20 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85044086\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eL1, N\/L2, L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMains supply input connections (Single-phase or Three-phase)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eU, V, W\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMotor output connection terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePE\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eProtective Earth ground connections\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAIF Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAutomation Interface for keypad (EMZ8201BB) or communication modules (EMF2102IB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E82EV751_2B is often designated in PLM systems under the code \u003cstrong\u003eE82EV751K2B\u003c\/strong\u003e. It is fully compatible with the Lenze EMZ8201BB parameterization keypad and the EMF2102IB LECOM-A (RS232\/RS485) communication module. When replacing an older 8200 Standard series drive, note that the 8200 Vector series uses a different parameter structure, requiring a manual transfer of settings rather than a direct copy-paste via older software versions.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAs a legacy phase-out model, thermal management is critical to preserving the unit's internal DC-bus capacitors. Ensure a minimum vertical mounting clearance of 100 mm above and below the drive. Continuous operation at the maximum 4.0 A output current in ambient temperatures exceeding 40 degC will accelerate capacitor degradation; external cabinet cooling or derating is highly recommended in these environments.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use low-capacitance, shielded motor cables to minimize high-frequency leakage currents. The cable shield must be grounded over a large surface area directly to the conductive mounting plate using grounding clamps. To prevent electromagnetic interference, never route control cables parallel to motor power cables; maintain a minimum physical separation of 10 cm.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Ensure all input power sources are completely de-energized and locked out before performing any wiring or maintenance. Wait at least 5 minutes after disconnecting the power supply to allow the internal DC-bus capacitors to fully discharge to safe voltage levels (\u0026lt; 50 VDC).\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the drive vertically on a flat, vibration-free conductive mounting plate inside the control cabinet to ensure proper heat dissipation and grounding.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the protective earth (PE) conductor to the designated ground terminal before making any other electrical connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the AC mains input to terminals L1\/N (for single-phase) or L1\/L2\/L3 (for three-phase) and the motor output to terminals U\/V\/W.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eInsert the required control module or keypad into the front AIF slot, ensuring it clicks securely into place before applying power.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047961963,"sku":"E82EV751_2B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev751-2b-lfwh0rpeucr.png?v=1776235890"},{"product_id":"lenze-e82ev371-2c-8200-series-variable-frequency-drive","title":"Lenze E82EV371_2C 8200-Series Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for precise speed and torque control in demanding industrial environments, the \u003cstrong\u003eLenze E82EV371_2C\u003c\/strong\u003e is a high-performance vector frequency inverter belonging to the modular \u003cstrong\u003e8200-series\u003c\/strong\u003e. This drive module is engineered to optimize the operation of three-phase AC motors, delivering a rated power output of 0.37 kW. Equipped with integrated radio interference suppression measures, the unit minimizes electromagnetic disturbance, ensuring high operational reliability and compliance with EMC guidelines in dense control cabinet installations.\u003c\/p\u003e\n\n\u003cp\u003eThe compact design of the \u003cstrong\u003eE82EV371_2C\u003c\/strong\u003e (also identified by the alternative code \u003cstrong\u003eE82EV371K2C\u003c\/strong\u003e) allows for space-saving integration into centralized control systems. Its vector control capabilities provide excellent dynamic response and high torque even at low rotational speeds, making it highly suitable for continuous production processes, machine building, and automation retrofits.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-precision vector control for optimal motor shaft performance and speed stability.\u003c\/li\u003e\n  \u003cli\u003eIntegrated interference suppression measures to ensure electromagnetic compatibility (EMC).\u003c\/li\u003e\n  \u003cli\u003eCompact bookstyle housing designed for space-efficient side-by-side mounting.\u003c\/li\u003e\n  \u003cli\u003eModular design supporting various plug-in communication modules and I\/O extensions.\u003c\/li\u003e\n  \u003cli\u003eRobust thermal management and protective functions against overvoltage, undervoltage, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaterial handling and conveyor systems requiring controlled acceleration and deceleration.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and labeling systems.\u003c\/li\u003e\n  \u003cli\u003eIndustrial pump and fan speed control for energy optimization.\u003c\/li\u003e\n  \u003cli\u003eGeneral machine tool construction and automated production lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eModel Number\u003c\/th\u003e\n      \u003cth\u003eAlternative Part Number\u003c\/th\u003e\n      \u003cth\u003eSeries\u003c\/th\u003e\n      \u003cth\u003ePower Rating\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE82EV371_2C\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE82EV371K2C\u003c\/td\u003e\n      \u003ctd\u003e8200-series\u003c\/td\u003e\n      \u003ctd\u003e0.37 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE82EV371_2C (E82EV371K2C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVariable Frequency Drive (VFD) \/ Vector Inverter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMains Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 x 230 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Power Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.37 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInterference Suppression\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated EMC filter measures\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.60 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e17.80 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.20 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.70 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Install the inverter vertically on a flat, thermally conductive mounting plate inside the control cabinet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e Maintain a minimum clearance of 100 mm above and below the unit to ensure unrestricted convection airflow and cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Use shielded motor cables and ensure low-impedance, large-area grounding of the cable shield to the mounting plate to maintain EMC compliance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMains Connection:\u003c\/strong\u003e Ensure the supply voltage matches the 3 x 230 V specification before applying power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105048224107,"sku":"E82EV371_2C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev371-2c-ssozthdtumu.png?v=1776235847"},{"product_id":"lenze-emf2102ib-v003-8200-series-interface-module","title":"Lenze EMF2102IB-V003 8200-series Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for seamless integration with Lenze 8200-series frequency inverters, the \u003cstrong\u003eEMF2102IB-V003\u003c\/strong\u003e communication module establishes reliable serial interfaces in industrial automation systems. This \u003cstrong\u003einterface module\u003c\/strong\u003e enables flexible point-to-point or multi-point data transmission, supporting both RS232 and RS485 communication protocols. Operating on a standard 24 VDC power supply, it facilitates direct integration into existing control cabinets and distributed drive architectures, ensuring robust data exchange for commissioning, parameterization, and system diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-protocol support accommodating both RS232 and RS485 serial communication standards.\u003c\/li\u003e\n  \u003cli\u003eDirect plug-in compatibility with Lenze 8200-series drive systems.\u003c\/li\u003e\n  \u003cli\u003eCompact form factor designed for space-saving installation within control panels.\u003c\/li\u003e\n  \u003cli\u003eReliable 24 VDC power input configuration.\u003c\/li\u003e\n  \u003cli\u003eRobust construction engineered to withstand demanding industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial drive communication networks and distributed control systems.\u003c\/li\u003e\n  \u003cli\u003eParameterization, monitoring, and diagnostics of Lenze 8200-series frequency inverters.\u003c\/li\u003e\n  \u003cli\u003eIntegration of legacy drive systems into PLC or SCADA architectures via serial links.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEMF2102IB-V003\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8200-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInterface Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRS232, RS485\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.10 cm x 10.20 cm x 10.20 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.10 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLifecycle Status\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePhase-Out \/ Legacy Spare Part\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the host frequency inverter is completely powered down and discharged before inserting or removing the interface module.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely into the designated slot on the front of the Lenze 8200-series inverter, ensuring all connector pins align correctly.\u003c\/li\u003e\n  \u003cli\u003eUse high-quality shielded cabling for RS232 and RS485 connections to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003eAdhere to standard industrial grounding practices to protect serial communication lines from transient voltage spikes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105048551787,"sku":"EMF2102IB-V003","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emf2102ib-v003-nbb4sxyl5m2.png?v=1776236306"},{"product_id":"lenze-emf2175ib-8200-series-fieldbus-module","title":"Lenze EMF2175IB 8200-series Fieldbus Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for seamless integration into industrial drive systems, the \u003cstrong\u003eEMF2175IB\u003c\/strong\u003e serves as a high-performance communication interface within the Lenze \u003cstrong\u003e8200-series\u003c\/strong\u003e frequency inverter ecosystem. This fieldbus module enables dual-protocol connectivity, supporting both \u003cstrong\u003eDeviceNet\u003c\/strong\u003e and \u003cstrong\u003eCANopen\u003c\/strong\u003e industrial networks. By facilitating direct digital control, parameterization, and diagnostics, the module eliminates the need for extensive analog wiring, providing robust real-time data exchange between the host controller and the drive. Its compact design allows for direct mounting onto the inverter, ensuring a secure and space-saving installation inside control cabinets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eDual-protocol compatibility supporting both DeviceNet and CANopen communication standards.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eDirect plug-in design engineered specifically for Lenze 8200-series frequency inverters.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eOptically isolated communication interfaces to prevent ground loops and protect sensitive control electronics.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eLow power consumption profile utilizing a 24 V DC external supply.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eDurable construction optimized for demanding industrial environments.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eDecentralized drive control in automated packaging machinery.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eConveyor systems and material handling networks.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eAutomotive assembly lines utilizing DeviceNet or CANopen architectures.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eGeneral mechanical engineering applications requiring remote drive parameterization.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctbody\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eEMF2175IB\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e8200-series\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eFieldbus Communication Module\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eDeviceNet, CANopen\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e24 V DC (±10%)\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eMax. 100 mA\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e270 VAC\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e7.60 cm x 7.60 cm x 5.10 cm\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e0.10 kg\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Lifecycle Phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003ePhase-Out \/ Legacy Spare Part\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tbody\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cp\u003e\u003cthead\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cth\u003eInterface Type\u003c\/th\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cth\u003eFunction \/ Description\u003c\/th\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/thead\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctbody\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eInternal multi-pin connector for direct attachment to the 8200-series drive slot.\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eFieldbus Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eStandardized terminal block for DeviceNet \/ CANopen network wiring (V-, CAN_L, Shield, CAN_H, V+).\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tbody\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eEnsure the host 8200-series frequency inverter is completely powered down and discharged before installing or removing the module.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003ePlug the EMF2175IB module firmly into the designated communication slot on the front of the inverter.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eTighten the integrated retaining screws to guarantee reliable grounding and mechanical stability.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eUse high-quality shielded twisted-pair cabling compliant with DeviceNet\/CANopen specifications to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eInstall a 120-ohm termination resistor at both physical ends of the network trunk line.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105048715627,"sku":"EMF2175IB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emf2175ib-ieos0vlz4k2.png?v=1776236336"},{"product_id":"lenze-epm-h505-touch-panel","title":"Lenze EPM-H505 Touch Panel","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to provide reliable operator interface capabilities in legacy industrial installations, the \u003cstrong\u003eLenze EPM-H505\u003c\/strong\u003e serves as a robust human-machine interface (HMI) for real-time machine monitoring and control. Featuring a high-contrast \u003cstrong\u003e5.7-inch STN display\u003c\/strong\u003e with a resolution of \u003cstrong\u003e320 x 240 pixels\u003c\/strong\u003e, this unit utilizes \u003cstrong\u003efour distinct blue tones\u003c\/strong\u003e to ensure optimal readability for operators under diverse factory lighting conditions. Engineered for seamless integration into existing control architectures, it operates on a standard \u003cstrong\u003e24 VDC\u003c\/strong\u003e power supply and communicates via an integrated \u003cstrong\u003eRS-232 serial interface\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Contrast Display:\u003c\/strong\u003e 5.7-inch STN screen with 320 x 240 pixel resolution and 4 blue tones for clear visualization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Serial Communication:\u003c\/strong\u003e Built-in RS-232 interface for direct, point-to-point connection to PLCs and controllers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Software Clock:\u003c\/strong\u003e Enables precise time-stamping of system events, alarms, and operational logs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficient Power Design:\u003c\/strong\u003e Low-power consumption rated at 10 Watts on a standard 24 VDC input.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Form Factor:\u003c\/strong\u003e Compact, durable construction designed to withstand harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eLegacy machine control panel replacements and system retrofits.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery, material handling, and conveyor control systems.\u003c\/li\u003e\n  \u003cli\u003eLocal process monitoring and parameter adjustment in factory automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px 12px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px 12px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eEPM-H505\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eSTN Display (4 Blue Tones)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e5.7 inches\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e320 x 240 Pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e10 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eCommunication Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eRS-232\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eReal-Time Clock\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eIntegrated Software Clock\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eProduct Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eObsolete \/ Legacy Spare Part\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eExport Control Regulations\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eECCN: N\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e15.8 x 21.0 x 3.6 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e1.36 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe EPM-H505 is a legacy HMI. When replacing an active unit, ensure that you have a verified backup of the original HMI project file (.vzs or equivalent Lenze HMI Designer format). Direct runtime extraction from a damaged unit is often restricted or impossible depending on the original security configurations.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this unit utilizes an STN display with 4 blue tones, its viewing angle is narrower than modern TFT displays. Avoid mounting the panel in locations with direct sunlight or high ambient glare. Additionally, ensure the 24 VDC supply is clean and isolated from heavy inductive loads to prevent communication dropouts over the RS-232 line.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eWhen fabricating the RS-232 cable, always use high-quality shielded twisted-pair cabling and ground the shield at the controller side only. Keep the cable length under 15 meters to prevent signal degradation and electromagnetic interference (EMI) issues.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-weight: bold;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eIsolate and lock out all electrical power sources before initiating physical installation or wiring. Verify that the 24 VDC power supply is completely de-energized to prevent damage to the internal logic boards and communication ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003ePrepare a clean panel cutout measuring approximately 21.0 cm x 15.8 cm, ensuring the mounting surface is flat and free of burrs.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInsert the HMI unit into the cutout, ensuring the integrated sealing gasket is properly seated to maintain the panel's environmental rating.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSecure the unit using the provided mounting clamps. Tighten them evenly to avoid warping the front bezel.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the RS-232 communication cable to the designated serial port, ensuring the connector screws are firmly tightened.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the 24 VDC power supply leads to the terminal block, verifying correct polarity before applying power.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105048846699,"sku":"EPM-H505","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/epm-h505-fcdzs5fggyu.png?v=1776236368"},{"product_id":"lenze-i55ae137b10v10000s-i550-series-ac-inverter-drive","title":"Lenze I55AE137B10V10000S i550 Series AC Inverter Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for space-restricted control cabinets, the \u003cstrong\u003eLenze I55AE137B10V10000S\u003c\/strong\u003e frequency inverter delivers precise speed and torque regulation for low-power motor systems. This compact drive converts single-phase 230V mains power into a variable-frequency three-phase output, making it highly suitable for running small three-phase AC motors from standard single-phase utility grids. As part of the reliable \u003cstrong\u003eLenze i550 series\u003c\/strong\u003e, this unit features a slim profile and high energy efficiency, minimizing thermal load inside industrial enclosures.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase Conversion:\u003c\/strong\u003e Efficiently converts 1-phase 230 VAC input to 3-phase 230 VAC output for standard industrial motors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Slim design allows side-by-side mounting in control panels, optimizing cabinet space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP20 Protection:\u003c\/strong\u003e Designed for clean, dry industrial environments with standard finger-safe terminal connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eScalable Integration:\u003c\/strong\u003e Fully compatible with the modular Lenze i500 range of communication and interface options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConveyor Systems:\u003c\/strong\u003e Precise speed control for small-scale material handling and packaging lines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePumps and Fans:\u003c\/strong\u003e Energy-efficient flow regulation in commercial HVAC and fluid transfer systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine Tooling:\u003c\/strong\u003e Spindle and auxiliary axis control in light-duty manufacturing machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eI55AE137B10V10000S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ei550 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.37 kW (0.5 HP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e230 VAC (1-Phase)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOutput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e230 VAC (3-Phase)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEnclosure Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e6.0 cm x 21.4 cm x 13.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.80 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe i550 series serves as the modern, high-efficiency replacement for legacy Lenze 8200 vector series drives. When migrating older systems to the i550 platform, parameter sets must be converted using the Lenze Easy Starter software tool, as direct parameter file transfers are not supported due to differences in firmware architecture.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this unit is IP20 rated, it relies heavily on convective airflow for cooling. In enclosed control panels, maintain a minimum clearance of 50 mm above and below the drive. Failure to provide adequate clearance under continuous 0.37 kW loads can lead to premature thermal tripping or overtemperature faults (Fault Code 0x2310).\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways ground the motor cable shield directly to the metal mounting plate using low-impedance EMC shield clamps. This prevents high-frequency common-mode currents from leaking into nearby sensor wiring, which can cause intermittent signal corruption on analog feedback loops.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Ensure all incoming AC power sources are completely de-energized and locked out before attempting installation or wiring. Wait at least 5 minutes after disconnecting power to allow the internal DC-bus capacitors to fully discharge to safe voltage levels.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the drive vertically on a flat, vibration-free metal backplate inside a clean, dust-free enclosure.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the single-phase 230 VAC mains supply to the L1 and N input terminals, ensuring proper protective earth (PE) grounding.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the three-phase motor leads to the U, V, and W output terminals using shielded motor cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eVerify all terminal screw torques conform to Lenze specifications before energizing the unit for commissioning.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049043307,"sku":"I55AE137B10V10000S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/i55ae137b10v10000s-wilnewpok2w.png?v=1776236783"},{"product_id":"lenze-evd4906-e-4900-series-servo-drive","title":"Lenze EVD4906-E 4900-series Servo Drive","description":"\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-demand industrial automation systems, the \u003cstrong\u003eLenze EVD4906-E\u003c\/strong\u003e serves as a high-performance \u003cstrong\u003eservo drive\u003c\/strong\u003e and DC drive converter within the legacy 4900-series. This robust power conversion unit is designed to deliver precise speed and torque control for DC motors in continuous production environments. By integrating advanced power electronics, the \u003cstrong\u003eEVD4906-E\u003c\/strong\u003e ensures stable operation, high dynamic response, and seamless integration into centralized control topologies.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-capacity power output designed for heavy-duty industrial DC motor control.\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical construction optimized for control cabinet installation.\u003c\/li\u003e\n  \u003cli\u003eIntegrated thermal management to ensure reliable continuous operation under load.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Lenze 4900-series system architecture and legacy control interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMetal processing and wire drawing machinery\u003c\/li\u003e\n  \u003cli\u003eExtruders and plastics processing equipment\u003c\/li\u003e\n  \u003cli\u003ePrinting presses and paper converting machinery\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and heavy-duty conveyor systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEVD4906-E\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAlternative Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e33.4906-E\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4900-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eServo Drive \/ DC Drive Converter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e84.0 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200.0 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e22.90 cm x 55.90 cm x 27.90 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install vertically in a control cabinet with adequate clearance at the top and bottom to facilitate natural convection or forced cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Ensure all power and control cables are shielded and routed separately to prevent electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a low-impedance ground connection to the cabinet backplate.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Maintain ambient temperatures within standard operating limits, avoiding exposure to corrosive gases or excessive moisture.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049108843,"sku":"EVD4906-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evd4906-e-0qz2nd2df2o.png?v=1776236401"},{"product_id":"lenze-e94apne1004-9400-series-power-supply-module","title":"Lenze E94APNE1004 9400-series Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered to deliver reliable DC bus power for demanding multi-axis drive systems, the \u003cstrong\u003eE94APNE1004\u003c\/strong\u003e serves as a high-capacity \u003cstrong\u003epower supply module\u003c\/strong\u003e within the globally recognized Lenze 9400-series. This module provides efficient energy distribution with a rated power output of 48.6 kW, making it highly suitable for heavy-duty industrial automation environments. Operating on a nominal voltage of 400 V, it accommodates a broad three-phase input range to maintain system stability despite supply voltage fluctuations. Its modular design allows for straightforward integration with various communication networks via optional extension cards, ensuring seamless coordination with centralized control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-capacity power delivery with a rated output of 48.6 kW.\u003c\/li\u003e\n  \u003cli\u003eWide three-phase input voltage range from 180 V to 550 V AC.\u003c\/li\u003e\n  \u003cli\u003eOptimized for DC bus configurations within multi-axis drive systems.\u003c\/li\u003e\n  \u003cli\u003eModular communication support for Ethernet, EtherCAT, POWERLINK, PROFINET, and PROFIBUS protocols.\u003c\/li\u003e\n  \u003cli\u003eRobust thermal and electrical design engineered for continuous industrial operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMulti-axis servo drive systems and motion control networks.\u003c\/li\u003e\n  \u003cli\u003eAutomated packaging machinery and high-speed cartoners.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, conveying, and storage retrieval systems.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly lines and metal forming applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eE94APNE1004\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003e9400-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Type\u003c\/strong\u003e\n      \u003ctd\u003ePower Supply Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eRated Power\u003c\/strong\u003e\n      \u003ctd\u003e48.6 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\n      \u003ctd\u003e3-phase AC 180 V to 550 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\n      \u003ctd\u003e400 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e15.42 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\n      \u003ctd\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCommodity Code\u003c\/strong\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor optimal performance and safety, mount the power supply module vertically inside an IP54 or higher rated control cabinet. Ensure that specified clearance distances above and below the unit are maintained to facilitate natural convection cooling. All electrical connections, particularly the high-voltage three-phase input and the DC bus links, must be wired using appropriately sized, shielded cables. Establish a low-impedance ground connection to the mounting plate to minimize electromagnetic interference (EMI) and comply with local electrical safety regulations.\u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049239915,"sku":"E94APNE1004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e94apne1004-wf3kytnmljo.png?v=1776236119"},{"product_id":"lenze-e82zafd-8200-series-canopen-function-module","title":"Lenze E82ZAFD 8200-series CANopen Function Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIntegrating seamlessly into the 8200 vector frequency inverter range, the \u003cstrong\u003eLenze E82ZAFD\u003c\/strong\u003e serves as a dedicated CANopen communication interface designed to facilitate high-speed, deterministic data exchange across industrial automation networks. This module mounts directly onto the front-facing Application Interface (AIF) slot of the drive, eliminating the need for external mounting hardware or additional control wiring.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDirect integration into the Lenze 8200 vector drive AIF slot.\u003c\/li\u003e\n  \u003cli\u003eFull compliance with the CANopen communication protocol according to DS301 profile specifications.\u003c\/li\u003e\n  \u003cli\u003eConfigurable baud rates up to 1 Mbps, adjustable via integrated DIP switches or internal drive parameter codes.\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation between the CAN bus network medium and the internal drive control electronics to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003eOnboard diagnostic LEDs providing real-time visual feedback on network status and module power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDecentralized drive control architectures in manufacturing and assembly lines.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis synchronized motion control applications.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems, material handling, and packaging machinery.\u003c\/li\u003e\n  \u003cli\u003eIntegration of legacy Lenze 8200 vector drives into modern CANopen master control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eE82ZAFD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8200-series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFunction Module \/ Communication Interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommunication Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCANopen (DS301)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eBaud Rate Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e20 kbps to 1 Mbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNode Address Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 to 63 (configurable via DIP switches or codes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInterface Slot Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAIF (Application Interface)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.02 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e80 mm x 50 mm x 30 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; width: 40%;\"\u003eTerminal \/ Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCAN_H\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCAN High Signal Line\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCAN_L\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCAN Low Signal Line\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eGND\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCAN Reference Ground (Isolated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E82ZAFD is backwards compatible with all standard Lenze 8200 vector frequency inverters ranging from 0.25 kW to 90 kW. It directly replaces non-isolated CAN communication modules. Note that depending on the firmware revision of your 8200 vector drive (specifically revisions below V2.0), certain advanced CANopen monitoring objects may have limited access, requiring configuration via the standard drive keypad parameter codes.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA common point of failure during commissioning is the omission of the physical 120-ohm termination resistor. The E82ZAFD does not feature an internal software-switchable termination resistor; therefore, a physical 120-ohm resistor must be wired externally across the CAN_H and CAN_L terminals at the first and last physical nodes of the bus. Operating without proper termination leads to intermittent frame errors, packet loss, and drive communication faults (typically triggering a CE0 or CE3 fault on the inverter).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo ensure robust noise immunity in high-EMI environments, use only high-quality shielded twisted-pair (STP) cabling specified for CAN networks. Route the communication cable at least 20 cm away from high-voltage motor output cables and AC supply lines. The cable shield must be grounded at a single point (typically at the master controller) to prevent ground loops from corrupting the differential communication signals.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eBefore installing or removing the E82ZAFD module, completely de-energize the main AC supply to the Lenze 8200 vector inverter. Wait at least 5 minutes for the internal DC-bus capacitors to fully discharge to safe voltage levels. Verify zero voltage at the power terminals before proceeding. Hot-plugging the module will cause permanent damage to the AIF interface and the drive's control board.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eEnsure the inverter is completely powered down and the DC-bus discharge time has elapsed.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eSet the required node address and baud rate using the DIP switches located on the side of the E82ZAFD module before inserting it into the slot.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eAlign the module carefully with the AIF slot on the front of the 8200 vector inverter and press firmly until the retaining clips click into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the CAN bus lines (CAN_H, CAN_L, and GND) to the pluggable terminal block, ensuring correct polarity and shielding termination.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049403755,"sku":"E82ZAFD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafd-ct4hzktvsne.png?v=1776235984"},{"product_id":"lenze-evf8246-e-v921-8200-series-variable-frequency-drive","title":"Lenze EVF8246-E-V921 8200-series Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for precise speed and torque control of three-phase asynchronous motors, the \u003cstrong\u003eLenze EVF8246-E-V921\u003c\/strong\u003e is a high-performance frequency inverter belonging to the modular \u003cstrong\u003e8200-series\u003c\/strong\u003e family. This variable frequency drive is designed to optimize energy consumption and process efficiency in demanding industrial environments, delivering a rated power output of 11 kW at 480 V.\u003c\/p\u003e\n\u003cp\u003eThe modular architecture of the \u003cstrong\u003eEVF8246-E-V921\u003c\/strong\u003e allows for flexible integration with various pluggable communication and I\/O modules, making it highly adaptable to existing control cabinet configurations. Although officially classified as a phase-out model since 2017, this robust drive remains a critical spare part for maintaining and extending the lifecycle of legacy automation systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eModular design supporting plug-in communication modules (such as CAN, PROFIBUS, or Interbus).\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eConfigurable V\/f characteristic control (linear or quadratic) for versatile motor adaptation.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eIntegrated motor overload protection and thermal monitoring to prevent equipment damage.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eCompact bookstyle housing designed for space-saving side-by-side mounting in control cabinets.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eHigh overload capacity to handle demanding starting torques and transient load spikes.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eConveyor and material handling systems.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eIndustrial pumps, fans, and ventilation systems.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003ePackaging machinery and automated assembly lines.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003eGeneral mechanical engineering and process control applications.\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctbody\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eEVF8246-E-V921\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e8200-series\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003eVariable Frequency Drive (VFD)\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e480 V AC\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e7.30 kg\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ctd\u003ePhase-Out (since 2017)\u003c\/td\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tr\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/tbody\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Install the drive vertically on a flat, thermally conductive mounting plate inside a control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain a minimum clearance of 100 mm above and below the unit to ensure unobstructed convective airflow and cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Use shielded motor cables with low-impedance 360-degree EMC shielding connections at both the drive and motor ends to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e Ensure the operating environment does not exceed the specified limits (typically up to 40 degC without derating).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049534827,"sku":"EVF8246-E-V921","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evf8246-e-v921-wl0n434tru5.png?v=1776236464"},{"product_id":"lenze-evs9327-ep-9300-series-servo-position-controller","title":"Lenze EVS9327-EP 9300-Series Servo Position Controller","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nManaging complex motion profiles in high-performance industrial environments, the \u003cstrong\u003eLenze EVS9327-EP\u003c\/strong\u003e serves as a high-precision servo position controller within the legacy \u003cstrong\u003e9300-Series\u003c\/strong\u003e ecosystem. This robust drive is engineered to deliver precise speed, torque, and position control for demanding electrical and mechanical automation architectures.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-precision control loop execution for synchronous and asynchronous AC servo motors.\u003c\/li\u003e\n  \u003cli\u003eIntegrated CAN system bus interface for seamless multi-axis synchronization and control.\u003c\/li\u003e\n  \u003cli\u003eModular expansion slots supporting auxiliary communication modules including PROFIBUS, LECOM, and Interbus.\u003c\/li\u003e\n  \u003cli\u003eIP20 protection rating optimized for space-saving control cabinet mounting.\u003c\/li\u003e\n  \u003cli\u003eFlexible configuration options for shared DC bus systems to optimize regenerative energy efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e High-speed indexing, wrapping, and cartoning systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Multi-axis gantry systems, pick-and-place units, and automated storage systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTextile Production:\u003c\/strong\u003e Synchronized speed control for winding and tensioning applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConverting \u0026amp; Printing:\u003c\/strong\u003e Precise web tension control and rotary knife positioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEVS9327-EP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e9300-Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDevice Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eServo Position Controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRated Power Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e15.0 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEnclosure Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eIntegrated Communication\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem Bus (CAN)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePhase-Out (Legacy Support Available)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePhysical Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e35.00 x 25.00 x 25.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eExport Control Classification (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem Bus (CAN) Interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eResolver Input Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEncoder Input \/ Output Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAnalog Inputs and Outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDigital Inputs and Outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nAs the 9300-Series has been in phase-out since 2017, direct replacements for the EVS9327-EP typically involve migrating to the modern Lenze i950 or 9400 HighLine servo drive platforms. Note that migrating to newer platforms requires converting the legacy parameter sets and PLC programs using Lenze Easy Starter or PLC Designer software. Ensure that existing fieldbus networks (such as PROFIBUS or CANopen) are fully mapped to the new controller's communication interfaces.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThermal management is critical for this 15.0 kW unit. When mounting inside enclosed control cabinets, maintain a minimum vertical clearance of 100 mm above and below the drive to ensure adequate convective airflow. In high-inertia applications with rapid deceleration cycles, an external brake resistor must be connected to prevent overvoltage faults (OU) on the DC bus.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nTo prevent electromagnetic interference (EMI) from corrupting feedback signals, always use high-quality, double-shielded twisted-pair cables for resolver (X2) and encoder (X3) connections. Ground the cable shields at both ends using low-impedance EMC shield clamps directly on the mounting plate. Avoid routing feedback cables parallel to high-voltage motor power cables.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #2d3748;\"\u003e\n    Hazardous electrical voltage remains present in the internal DC bus capacitors for up to 5 minutes after disconnecting the main power supply. Always verify that the DC bus voltage has discharged to 0 V using a calibrated voltmeter before initiating any physical handling, wiring, or maintenance procedures.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the drive vertically on a flat, grounded metal subpanel inside an IP54 or higher rated industrial enclosure to ensure proper heat dissipation and EMC grounding.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the protective earth (PE) conductors to the central grounding terminal, ensuring low-impedance metal-to-metal contact.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the main AC power supply lines to the input terminals and the motor power cables to the output terminals, utilizing specified torque values to secure all screw connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the required communication module (if applicable) into the front expansion slot and connect the control, feedback, and system bus cables.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049600363,"sku":"EVS9327-EP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9327-ep-ygifqswxp2o.png?v=1776236703"},{"product_id":"lenze-evs9324-epv004-9300-series-servo-position-controller","title":"Lenze EVS9324-EPV004 9300 Series Servo Position Controller","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Designed for high-precision motion control, the \u003cstrong\u003eLenze EVS9324-EPV004\u003c\/strong\u003e serves as a robust servo position controller within the 9300 Series architecture. This \u003cstrong\u003e3.0 kW\u003c\/strong\u003e rated unit provides closed-loop positioning and speed control for demanding industrial automation environments. Featuring an \u003cstrong\u003eIP20\u003c\/strong\u003e protection rating, it is engineered for direct installation inside electrical control cabinets, offering reliable performance and seamless integration with legacy fieldbus networks.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eIntegrated position controller with configurable motion profiles and homing routines.\u003c\/li\u003e\n  \u003cli\u003eRobust IP20 degree of protection, optimized for space-saving control cabinet mounting.\u003c\/li\u003e\n  \u003cli\u003eHigh-performance resolver feedback interface for precise closed-loop control.\u003c\/li\u003e\n  \u003cli\u003eFlexible system bus communication capabilities for multi-axis synchronization.\u003c\/li\u003e\n  \u003cli\u003eThermal monitoring and overload protection to safeguard the drive and motor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e High-speed indexing, wrapping, and cartoning systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Gantry systems, automated storage\/retrieval systems (ASRS), and transfer carriages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTextile Manufacturing:\u003c\/strong\u003e Precise winding, tension control, and feed-axis synchronization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrinting and Paper Processing:\u003c\/strong\u003e Rotary cut-offs, cross-cutters, and web-guiding systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEVS9324-EPV004\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e9300 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eServo Position Controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRated Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.0 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDegree of Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePhase-Out \/ Legacy Spare Part\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e35.00 x 25.00 x 9.70 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eTerminal \/ Connector\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eControl Terminals (Digital Inputs\/Outputs, Analog Inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eResolver Input (Feedback loop connection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem Bus (CAN interface for multi-drive networking)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEncoder Output \/ Encoder Simulation\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The EVS9324-EPV004 is a dedicated positioning controller (\"EP\" variant) and cannot be directly swapped with standard speed controllers (\"ES\" variants) without modifying the system PLC program and drive parameter sets. When replacing older hardware revisions, ensure that the firmware version of the replacement unit matches or is backward-compatible with your existing system configuration. Parameter transfers should be executed using Lenze Global Drive Control (GDC) software.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  To ensure reliable operation, thermal management within the enclosure is critical. When mounting multiple 9300 Series drives side-by-side, maintain a minimum lateral clearance of 10 mm and a vertical clearance of at least 100 mm to facilitate natural convection. High-inertia applications requiring rapid deceleration must be paired with an appropriately sized external braking resistor connected to terminals UG+ and BR to prevent Overvoltage (OU) faults on the DC bus.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Always use double-shielded twisted-pair cabling for the resolver feedback (X2) and system bus (X5) to mitigate electromagnetic interference (EMI). The cable shields must be grounded at both ends using low-impedance EMC shield clamps directly on the mounting plate. Before applying main 3-phase AC power, verify that the auxiliary 24 VDC control supply is stable and correctly wired to ensure the control board initializes properly.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Hazardous voltage may be present on the power terminals for up to 5 minutes after disconnecting the AC supply. Always verify that the DC-bus voltage (measured between terminals UG+ and UG-) has dropped below 50 VDC using a calibrated multimeter before performing any physical installation, wiring, or maintenance.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eMount the drive vertically on a flat, conductive, and grounded metallic backplate to ensure optimal EMC shielding and heat dissipation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the protective earth (PE) conductor to the drive's primary grounding terminal before establishing any other electrical connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eWire the motor power phases (U, V, W) and connect the resolver or encoder feedback cable to the X2 port.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the 24 VDC auxiliary control power supply and terminate the control signals on the X1 block.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eApply the main 3-phase AC input power and initiate the commissioning sequence via Lenze GDC software.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049698667,"sku":"EVS9324-EPV004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9324-epv004-huijna0jdlf.png?v=1776236610"},{"product_id":"lenze-e84avsce5524sb0-8400-stateline-variable-frequency-drive","title":"Lenze E84AVSCE5524SB0 8400 StateLine Variable Frequency Drive","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEfficient motor control and precise speed regulation are achieved through the \u003cstrong\u003eE84AVSCE5524SB0\u003c\/strong\u003e variable frequency drive, a core component of the robust Lenze \u003cstrong\u003e8400 StateLine\u003c\/strong\u003e series. Engineered for demanding industrial environments, this frequency inverter delivers a power output of 5.5 kW and operates across 400\/500 V mains configurations. It features an integrated Safe Torque Off (STO) safety function, ensuring high-level operational safety and compliance with international machinery directives. Designed to optimize energy consumption and streamline machine operations, this drive is suitable for both standalone and coordinated multi-drive systems in heavy-duty applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower rating of 5.5 kW optimized for heavy-duty industrial applications.\u003c\/li\u003e\n\u003cli\u003eCompatible with 400\/500 V AC mains supplies.\u003c\/li\u003e\n\u003cli\u003eIntegrated Safe Torque Off (STO) safety system for reliable emergency stop functions.\u003c\/li\u003e\n\u003cli\u003ePart of the modular Lenze 8400 StateLine series, offering easy integration and scalability.\u003c\/li\u003e\n\u003cli\u003eRobust mechanical construction designed for control cabinet installation.\u003c\/li\u003e\n\u003cli\u003eHigh energy efficiency and precise dynamic motor control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConveyor systems and material handling machinery.\u003c\/li\u003e\n\u003cli\u003eIndustrial pumps, fans, and ventilation systems.\u003c\/li\u003e\n\u003cli\u003ePackaging and processing equipment.\u003c\/li\u003e\n\u003cli\u003eMachine tool auxiliary drives and assembly lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003cstrong\u003eSafety Function\u003c\/strong\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE84AVSCE5524SB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8400 StateLine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariable Frequency Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400 \/ 500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Torque Off (STO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e130 mm x 290 mm x 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049764203,"sku":"E84AVSCE5524SB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e84avsce5524sb0-1rk3gvfb5nd.png?v=1776236105"},{"product_id":"lenze-evf9325-evv004-9300-series-variable-frequency-drive","title":"Lenze EVF9325-EVV004 9300-Series Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-performance speed and torque control, the \u003cstrong\u003eEVF9325-EVV004\u003c\/strong\u003e vector frequency inverter provides reliable dynamic response for three-phase AC induction motors. This module integrates seamlessly into complex automation architectures, supporting precise velocity regulation and system efficiency. Part of the established Lenze 9300 Vector series, it features advanced control algorithms that ensure stable operation even under fluctuating load conditions.\u003c\/p\u003e\n\n\u003cp\u003eThe drive is equipped with modular interface slots, allowing for flexible integration with various fieldbus communication protocols. Its robust thermal management and integrated protective functions make it highly suitable for demanding industrial environments where continuous operation and minimal downtime are critical.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-precision vector control for optimal dynamic torque and speed response.\u003c\/li\u003e\n  \u003cli\u003eModular expansion slot supporting standard industrial communication modules.\u003c\/li\u003e\n  \u003cli\u003eIntegrated motor overload protection and thermal monitoring.\u003c\/li\u003e\n  \u003cli\u003eConfigurable digital and analog I\/O channels for versatile system integration.\u003c\/li\u003e\n  \u003cli\u003eEnergy-efficient operation with optimized switching frequencies to reduce thermal losses.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in protection against overvoltage, undervoltage, phase failure, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConveyor and material handling systems.\u003c\/li\u003e\n  \u003cli\u003ePackaging and printing machinery.\u003c\/li\u003e\n  \u003cli\u003eIndustrial pumps, fans, and compressors.\u003c\/li\u003e\n  \u003cli\u003eMachine tool axes and positioning systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003eEVF9325-EVV004\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003e9300 Vector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e3-phase 320 V AC to 528 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n      \u003ctd\u003e45 Hz to 65 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage\u003c\/td\u003e\n      \u003ctd\u003e0 to Max Input Voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Mode\u003c\/td\u003e\n      \u003ctd\u003eVector control, V\/f characteristic control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +40 degC (up to +55 degC with derating)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Group\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eL1, L2, L3\u003c\/td\u003e\n      \u003ctd\u003eMains supply input connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eU, V, W\u003c\/td\u003e\n      \u003ctd\u003eMotor output connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePE\u003c\/td\u003e\n      \u003ctd\u003eProtective Earth \/ Ground terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eX3\u003c\/td\u003e\n      \u003ctd\u003eAnalog input and output terminal strip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eX5\u003c\/td\u003e\n      \u003ctd\u003eDigital input and output terminal strip\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the drive vertically on a flat, vibration-free surface inside a suitable control cabinet. Maintain a minimum clearance of 100 mm above and below the unit to ensure unrestricted cooling airflow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use shielded motor cables with low-resistance 360-degree grounding at both ends to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the PE conductor directly to the central grounding point of the control cabinet to ensure safe and reliable operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route control and signal cables separately from power and motor cables to prevent capacitive coupling and signal noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003ecUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049829739,"sku":"EVF9325-EVV004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evf9325-evv004-hyc4pfrn3i1.png?v=1776236502"},{"product_id":"lenze-e84avsce7514sx0-8400-series-variable-frequency-drive","title":"Lenze E84AVSCE7514SX0 8400 Series Variable Frequency Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding precise speed and torque control for three-phase asynchronous motors, the Lenze E84AVSCE7514SX0 is an industrial frequency inverter designed for space-saving control cabinet installation. Operating on a \u003cstrong\u003e3-phase 400\/500 V AC\u003c\/strong\u003e mains supply, this \u003cstrong\u003e0.75 kW (1.0 HP)\u003c\/strong\u003e rated unit belongs to the highly reliable \u003cstrong\u003e8400 StateLine\u003c\/strong\u003e series. It features integrated interference suppression measures to ensure electromagnetic compatibility (EMC) in demanding industrial environments, minimizing electrical noise without requiring external filter modules in standard configurations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eOptimized for cabinet installation with a compact IP20 housing design.\u003c\/li\u003e\n  \u003cli\u003eIntegrated EMC filter (interference suppression) compliant with industrial standards.\u003c\/li\u003e\n  \u003cli\u003eV\/f characteristic control (linear or quadratic) and sensorless vector control for dynamic torque response.\u003c\/li\u003e\n  \u003cli\u003eMonitored ramp functions, quick stop, and DC braking for controlled deceleration.\u003c\/li\u003e\n  \u003cli\u003eOnboard CANopen system bus interface for seamless integration into distributed automation architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eConveyor systems and material handling lines\u003c\/li\u003e\n  \u003cli\u003eIndustrial pumps, fans, and ventilation blowers\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and indexing tables\u003c\/li\u003e\n  \u003cli\u003eMachine tool auxiliary drives\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eE84AVSCE7514SX0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8400 StateLine\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMains Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3 AC 400 V \/ 500 V (50\/60 Hz)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.75 kW (1.0 HP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEnclosure Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommunication Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCANopen (onboard)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.20 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e180 x 140 x 80 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E84AVSCE7514SX0 belongs to the 8400 StateLine family. It can directly replace older 8200 vector series drives of equivalent power ratings, though physical mounting footprints and control terminal layouts differ. Ensure that any existing CANopen configuration files (.EDS) are updated in your PLC master (such as a Siemens S7 or Lenze Controller) to reflect the 8400 StateLine profile.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen operating at the upper limit of 500 V AC, thermal dissipation increases slightly. Maintain a minimum clearance of 100 mm above and below the unit inside the enclosure to prevent localized overheating. Avoid running the drive continuously below 10 Hz without an external forced-cooling fan on the motor, as standard self-ventilated motors will overheat at low speeds under constant torque loads.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUse shielded motor cables with a low-impedance 360-degree shield connection at both the drive's PE bracket and the motor terminal box. Commissioning is best performed using the Lenze L-force Engineer software via an optional USB diagnostic adapter (E84DGCDXM). Ensure the termination resistor (120 Ohm) is switched on at the physical ends of the CANopen network segment.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous electrical voltage remains present in the internal DC-bus capacitors for up to 5 minutes after disconnecting the mains supply. Always verify that the DC-bus voltage has discharged to 0 V using a calibrated digital multimeter before handling any power terminals or wiring connections. Failure to comply can result in severe electrical shock or death.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the drive vertically on a flat, vibration-free backplate inside an IP54 or higher rated control cabinet to protect against dust and moisture.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the protective earth (PE) conductor to the designated grounding terminal prior to making any other electrical connections.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the 3-phase AC mains supply to terminals L1, L2, and L3, and the motor phases to terminals U, V, and W using shielded cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the control terminals and the CANopen bus lines, ensuring proper shielding and routing away from high-voltage power cables.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049895275,"sku":"E84AVSCE7514SX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e84avsce7514sx0-2ycvesi1fld.png?v=1776236106"},{"product_id":"lenze-e94azps0034-9400-series-backplane-module","title":"Lenze E94AZPS0034 9400 Series Backplane Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for high-performance multi-axis drive systems, the \u003cstrong\u003eLenze E94AZPS0034\u003c\/strong\u003e serves as a central backplane interface within the 9400 series automation architecture. This module facilitates reliable power distribution and system bus communication, ensuring seamless integration of modular drive controllers in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSpecifically designed for integration with Lenze 9400 HighLine and StateLine servo drive systems.\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical mounting and electrical connection interface for secure cabinet installation.\u003c\/li\u003e\n  \u003cli\u003eIntegrated DC-bus connection pathways to support efficient energy sharing between drive modules.\u003c\/li\u003e\n  \u003cli\u003eHigh-durability terminal contacts engineered to withstand continuous industrial vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eMulti-axis synchronized motion control systems in packaging and converting machinery.\u003c\/li\u003e\n  \u003cli\u003eAutomated material handling, gantry systems, and logistics sorting lines.\u003c\/li\u003e\n  \u003cli\u003eTextile manufacturing machinery requiring precise speed and torque control.\u003c\/li\u003e\n  \u003cli\u003ePrinting presses and continuous web processing applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eE94AZPS0034\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e9400 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDigital Module \/ Backplane\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eActive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E94AZPS0034 backplane is specifically engineered for the 9400 series drive footprint. When replacing older backplane revisions, verify that the physical slot dimensions and bus connector pin alignments match the existing cabinet layout, as physical keying prevents incorrect module insertion.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen configuring multi-axis systems on a shared backplane, ensure that the total continuous DC-bus current does not exceed the rated carrying capacity of the backplane copper rails. Inadequate spacing or blocked ventilation paths below the backplane assembly can lead to localized thermal stress on the internal bus connections.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways verify the integrity of the protective earth (PE) connection directly on the backplane chassis before mounting the active drive controllers. Use calibrated torque wrenches on all primary power terminal connections to prevent high-resistance contact points that can cause thermal damage under full load conditions.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eEnsure all primary AC power sources and auxiliary 24VDC control power are completely de-energized before handling the backplane. Residual voltage in the DC-bus capacitors of connected 9400 drives can remain at lethal levels (greater than 50VDC) for up to 10 minutes after disconnection. Verify zero voltage with a calibrated multimeter before starting work.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the backplane vertically onto a flat, conductive, and grounded subpanel within the electrical enclosure to ensure proper thermal dissipation and EMC shielding.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eSecurely fasten the backplane mounting screws to the specified torque rating to establish a low-impedance ground path to the cabinet backplate.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eCarefully align and insert the 9400 series drive modules into the backplane slots, ensuring the bus connectors seat fully without forcing the physical alignment pins.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049993579,"sku":"E94AZPS0034","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e94azps0034-qdr15wpprzc.png?v=1776236227"},{"product_id":"lenze-e82zafpc-8200-series-communication-module","title":"Lenze E82ZAFPC 8200-series Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned to facilitate seamless fieldbus integration, the \u003cstrong\u003eLenze E82ZAFPC\u003c\/strong\u003e serves as a dedicated \u003cstrong\u003ePROFIBUS communication module\u003c\/strong\u003e for the 8200-series frequency inverters. This interface module enables direct connection of the drive controller to a PROFIBUS-DP network, allowing for high-speed cyclic process data exchange and acyclic parameter access. By integrating this module into your control architecture, operators can achieve centralized control, real-time diagnostics, and remote parameterization of the connected drive systems from a master PLC or distributed control system.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for industrial environments, the module mounts directly onto the application interface (AIF) slot of the 8200-series vector inverters. This plug-and-play design minimizes wiring complexity and reduces installation time, making it a reliable choice for both new system deployments and legacy machinery retrofits.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect compatibility with Lenze 8200-series vector frequency inverters.\u003c\/li\u003e\n  \u003cli\u003eSupports the standard PROFIBUS-DP communication protocol for high-speed data transmission.\u003c\/li\u003e\n  \u003cli\u003eEnables both cyclic process data transfer and acyclic parameter configuration.\u003c\/li\u003e\n  \u003cli\u003eCompact, plug-on design that mounts directly into the drive's AIF slot.\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic indicators for quick network and communication status verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFactory automation and centralized machine control.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and material handling applications.\u003c\/li\u003e\n  \u003cli\u003ePumping, ventilation, and HVAC systems utilizing legacy Lenze drives.\u003c\/li\u003e\n  \u003cli\u003eRetrofitting and maintenance of existing production lines requiring fieldbus connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003eE82ZAFPC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003e8200-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eModule Type\u003c\/strong\u003e\n      \u003ctd\u003ePROFIBUS Communication Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCommodity Code\u003c\/strong\u003e\n      \u003ctd\u003e85044086\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure safe and reliable operation, adhere to the following engineering guidelines during installation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure the host frequency inverter is completely powered down and that the DC-bus capacitors have fully discharged before inserting or removing the communication module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Plug the E82ZAFPC module firmly into the designated AIF slot on the front of the 8200-series inverter. Secure the module using the integrated retaining screws to guarantee proper grounding and mechanical stability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Use high-quality, shielded twisted-pair cables compliant with PROFIBUS standards. Ensure the cable shield is grounded over a wide area at both ends of the connection to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAddressing:\u003c\/strong\u003e Configure the station address using the onboard DIP switches or via the drive's internal parameters prior to commissioning the network.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050059115,"sku":"E82ZAFPC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafpc-hd3diiz5001.png?v=1776235993"},{"product_id":"lenze-evs9325-ekv004-9300-series-servo-drive","title":"Lenze EVS9325-EKV004 9300 Series Servo Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOptimized for high-precision motion control, the Lenze EVS9325-EKV004 servo drive delivers reliable dynamic performance within the legacy 9300 Series architecture. This industrial servo controller features integrated cam profiling capabilities, making it highly suitable for complex synchronized motion sequences. Engineered with a \u003cstrong\u003e5.5 kW rated power\u003c\/strong\u003e capacity and housed in an \u003cstrong\u003eIP20 rated enclosure\u003c\/strong\u003e, the unit is designed for space-efficient control cabinet installation. Although this model is currently in its phase-out lifecycle stage, it remains a critical component for maintaining and servicing existing high-performance automation systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIntegrated cam profiling functionality for precise electronic synchronization.\u003c\/li\u003e\n  \u003cli\u003eRated power output of 5.5 kW to handle demanding dynamic loads.\u003c\/li\u003e\n  \u003cli\u003eIP20 protection class designed for clean, dry control cabinet environments.\u003c\/li\u003e\n  \u003cli\u003eCompact physical footprint to optimize mounting panel space.\u003c\/li\u003e\n  \u003cli\u003eRobust thermal management and diagnostic capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003ePackaging machinery and continuous wrapping systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, gantry systems, and high-speed conveying.\u003c\/li\u003e\n  \u003cli\u003eRotary indexing tables and electronic gearboxes.\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly lines requiring synchronized multi-axis motion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eEVS9325-EKV004\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9300 Series (Servo Cam Profiler)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e5.5 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEnclosure Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePhase-Out (Active until 2017)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePhysical Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e35.00 x 25.00 x 13.50 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eExport Control Classification (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAs a legacy component of the Lenze 9300 series, direct physical drop-in replacements are limited. For modern system retrofits, migration to the Lenze i950 cabinet servo inverter series is recommended. Note that migrating to newer platforms requires updated control configurations, mechanical mounting adjustments, and fieldbus communication mapping.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause the unit is rated IP20, it must be installed in a clean, dust-free control cabinet with adequate ventilation. At a 5.5 kW power rating, thermal dissipation must be carefully calculated. Ensure that the cabinet cooling system can handle the continuous heat output of the drive under peak operating cycles to prevent thermal tripping.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen replacing an existing EVS9325-EKV004, always back up the parameter set from the old drive using Lenze Global Drive Control (GDC) software before decommissioning. Ensure that the parameter chip is compatible with the firmware revision of the replacement unit to avoid initialization errors during startup.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources before handling or wiring the drive. After disconnecting the main AC power supply, wait at least 5 minutes to allow the internal DC-bus capacitors to discharge fully to safe voltage levels before touching terminals.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; margin-right: 10px; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the servo drive vertically on a flat, vibration-resistant backplate inside a protected control enclosure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; margin-right: 10px; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the protective earth (PE) conductor to the designated grounding terminal prior to making any other electrical connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; margin-right: 10px; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eRoute motor power and resolver\/encoder cables separately from control signaling lines to minimize electromagnetic interference (EMI).\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; margin-right: 10px; font-weight: bold;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify all terminal connection torques and ensure correct polarity of the DC bus and AC input lines before energizing the system.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050157419,"sku":"EVS9325-EKV004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9325-ekv004-yflo4bzxdsj.png?v=1776236645"},{"product_id":"lenze-emb9352-e-9300-series-power-supply-brake-chopper-module","title":"Lenze EMB9352-E 9300-Series Power Supply Brake Chopper Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to manage DC bus power distribution and regenerative braking energy within multi-axis drive systems, the \u003cstrong\u003eLenze EMB9352-E\u003c\/strong\u003e serves as a dedicated power supply and brake chopper module for the 9300-Series vector control range. This module provides a centralized DC link supply for multiple servo inverters while safely dissipating regenerative energy generated during rapid deceleration phases, protecting the entire drive lineup from overvoltage faults.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIntegrated high-capacity brake chopper to handle dynamic deceleration cycles.\u003c\/li\u003e\n  \u003cli\u003eDirect DC bus connection terminals for efficient energy sharing between multi-axis drives.\u003c\/li\u003e\n  \u003cli\u003eCompact bookstyle housing designed for space-optimized control cabinet installation.\u003c\/li\u003e\n  \u003cli\u003eDedicated thermal monitoring loop to prevent external brake resistor overheating.\u003c\/li\u003e\n  \u003cli\u003eSeamless integration with Lenze 9300-Series servo controllers and vector inverters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eMulti-axis packaging machinery and high-speed wrapping systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling gantries, hoists, and automated storage retrieval systems (ASRS).\u003c\/li\u003e\n  \u003cli\u003eContinuous printing presses and paper processing machinery.\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly lines requiring coordinated deceleration of high-inertia loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eEMB9352-E\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9300-Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePower Supply \/ Brake Chopper Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eLifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePhase-Out (Legacy Spare Part)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWidth\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e51 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eHeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e356 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDepth\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e203 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.20 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e+UG, -UG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDC Bus Link Connection to Servo Inverters\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRb1, Rb2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eExternal Braking Resistor Connection Terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eT1, T2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eThermal Contact Input for Braking Resistor Overload Protection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePE\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eProtective Earth Grounding Stud\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe EMB9352-E is fully compatible with Lenze 9300-Series EVF93xx and EVS93xx servo controllers. When replacing older revisions of this module, ensure that the DC bus voltage thresholds configured in your main drive parameters match the hardware specifications of the replacement unit to prevent premature chopper activation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent thermal pooling inside the control cabinet, maintain a minimum vertical clearance of 100 mm above and below the module. If the external braking resistor is undersized or lacks sufficient ventilation, the chopper module may experience thermal stress, leading to a permanent open-circuit fault on the DC bus.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use shielded, low-capacitance cables for the connection between the EMB9352-E and the external braking resistor. Ground the cable shield on both ends using low-impedance EMC shield clamps to prevent high-frequency switching noise from corrupting nearby encoder or fieldbus communication lines.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING: HIGH VOLTAGE RISK\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all AC mains power sources before working on the DC bus link. Residual charge in the DC bus capacitors can remain at lethal levels (above 50V DC) for up to 5 minutes after power-off. Always measure the voltage between the +UG and -UG terminals with a calibrated digital multimeter before initiating physical service.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the module vertically on a flat, conductive, and grounded mounting plate inside the enclosure to ensure optimal heat dissipation and EMC grounding.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the DC bus terminals (+UG and -UG) to the adjacent servo inverters using the shortest possible busbars or twisted copper conductors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the external braking resistor to terminals Rb1 and Rb2. Ensure the thermal overload contact of the resistor is wired directly into the T1\/T2 monitoring loop to trigger a system-wide shutdown in case of resistor overheating.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050222955,"sku":"EMB9352-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emb9352-e-fhx45lhd3wi.png?v=1776236297"},{"product_id":"lenze-evs9328-epv004-9300-series-servo-position-controller","title":"Lenze EVS9328-EPV004 9300 Series Servo Position Controller","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDelivering 22.0 kW of precise motion control, the \u003cstrong\u003eLenze EVS9328-EPV004\u003c\/strong\u003e serves as a high-performance servo position controller within the legacy \u003cstrong\u003e9300 Series\u003c\/strong\u003e architecture. This unit is engineered to execute complex positioning profiles, speed control, and torque-matching tasks in demanding industrial environments. Featuring an IP20 protection rating, it is designed for clean-room or control-cabinet installation, integrating seamlessly with master PLC systems via dedicated fieldbus interfaces and analog\/digital I\/O channels.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-precision positioning control with integrated profile generators.\u003c\/li\u003e\n  \u003cli\u003eRobust 22.0 kW rated power output for heavy-duty dynamic loads.\u003c\/li\u003e\n  \u003cli\u003eIP20 rated compact housing optimized for space-saving control cabinet mounting.\u003c\/li\u003e\n  \u003cli\u003eModular communication slot (AIF) supporting fieldbus expansion modules.\u003c\/li\u003e\n  \u003cli\u003eComprehensive protective functions including overvoltage, undervoltage, and short-circuit monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e High-speed indexing, rotary cutters, and electronic gearing systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Precise gantry positioning, automated storage\/retrieval systems (ASRS), and transfer carriages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTextile Manufacturing:\u003c\/strong\u003e Synchronized multi-axis winding and tension control systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrinting Presses:\u003c\/strong\u003e Register control and continuous web tensioning adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #2b6cb0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEVS9328-EPV004\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e9300 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eDevice Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eServo Position Controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eRated Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e22.0 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eEnclosure Protection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePhase-Out (Legacy Support Available)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e35.00 x 25.00 x 25.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eExport Control Classification (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #2b6cb0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eTerminal \/ Interface\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eL1, L2, L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eThree-Phase AC Mains Supply Input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eU, V, W\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMotor Phase Connections (Output)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003e+UG, -UG\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDC Bus Connection (for shared DC bus configurations)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eX1 \/ X2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAnalog and Digital Control Terminals (I\/O)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #2b6cb0;\"\u003eAIF Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAutomation Interface for communication modules (e.g., CANopen, PROFIBUS, LECOM)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe EVS9328-EPV004 is a dedicated positioning controller (\"EP\" variant). It is not directly interchangeable with standard speed controllers (\"ES\" variants) or register controllers (\"EVG\" variants) without modifying the PLC control logic and parameter sets. When replacing legacy units, ensure that the AIF communication module (such as the EMF2102IB or EMF2133IB) is transferred to the new unit and that the firmware revision matches to prevent communication timeouts with the master controller.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDuring highly dynamic deceleration cycles, the internal DC bus voltage can rise rapidly. If the system experiences frequent \"OU\" (Overvoltage) faults, verify that an external brake resistor (Lenze CHO series) is properly sized, connected, and configured in the parameters. Ensure the control cabinet has adequate forced-air ventilation, as the 22.0 kW unit generates significant thermal dissipation under continuous peak torque demands.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use double-shielded twisted-pair cables for resolver and encoder feedback connections to prevent high-frequency noise injection from the motor power lines. Ground the motor cable shield at both ends using low-impedance EMC shield clamps. Parameterization can be performed using Lenze Global Drive Control (GDC) software via the AIF interface; ensure the baud rate of the PC adapter matches the drive's default serial settings before attempting connection.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eHazardous electrical voltages remain present in the DC bus capacitors for up to 5 minutes after disconnecting the mains power supply. Measure the voltage between terminals +UG and -UG to ensure it has dropped below 50 VDC before performing any wiring, maintenance, or module replacement tasks.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the servo controller vertically inside an IP54 or higher rated control cabinet, leaving a minimum of 100 mm clearance at the top and bottom for unobstructed cooling airflow.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the protective earth (PE) conductor to the central ground busbar of the cabinet before making any other electrical connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the three-phase AC mains supply to terminals L1, L2, and L3 through an appropriately rated circuit breaker and line filter.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the motor phases to terminals U, V, and W, ensuring correct phase rotation to prevent uncontrolled runaway conditions during commissioning.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050255723,"sku":"EVS9328-EPV004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9328-epv004-dcrqsce5h35.png?v=1776236719"},{"product_id":"lenze-evs9331-es-9300-series-servo-drive","title":"Lenze EVS9331-ES 9300-Series Servo Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-performance motion control, the \u003cstrong\u003eEVS9331-ES\u003c\/strong\u003e serves as a robust \u003cstrong\u003eservo drive\u003c\/strong\u003e within the legacy Lenze 9300-Series portfolio. This industrial servo inverter provides precise speed, torque, and position control for demanding automation applications. Operating with a rated power output of 55.0 kW, the unit is housed in an IP20-rated enclosure designed for control cabinet installation. It supports integration with various fieldbus systems and feedback sensors to maintain dynamic system performance in heavy-duty machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-performance vector control and servo functionality.\u003c\/li\u003e\n  \u003cli\u003eRated power output of 55.0 kW for heavy-duty industrial applications.\u003c\/li\u003e\n  \u003cli\u003eIP20 protection class designed for clean, dry control cabinet environments.\u003c\/li\u003e\n  \u003cli\u003eModular expansion options for communication and feedback interfaces.\u003c\/li\u003e\n  \u003cli\u003eComprehensive diagnostic and status monitoring capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePackaging machinery and systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor systems.\u003c\/li\u003e\n  \u003cli\u003ePrinting and paper processing lines.\u003c\/li\u003e\n  \u003cli\u003eTextile manufacturing machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003eEVS9331-ES\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003e9300-Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Type\u003c\/strong\u003e\n      \u003ctd\u003eServo Drive \/ Servo Inverter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eRated Power\u003c\/strong\u003e\n      \u003ctd\u003e55.0 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e59.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\n      \u003ctd\u003e68.00 x 44.00 x 28.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCommodity Code\u003c\/strong\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Lifecycle Status\u003c\/strong\u003e\n      \u003ctd\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install vertically inside an IP20-compliant control cabinet to ensure optimal heat dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain adequate clearance at the top and bottom of the unit to allow unrestricted cooling airflow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a low-impedance PE connection to the mounting plate to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use shielded motor cables and control lines, ensuring the shields are grounded at both ends.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050321259,"sku":"EVS9331-ES","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9331-es-pqlorcetojr.png?v=1776236762"},{"product_id":"lenze-eln3-0120h017-eln3-three-phase-mains-choke","title":"Lenze ELN3-0120H017 ELN3 Three-Phase Mains Choke","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for power quality optimization in industrial drive systems, the \u003cstrong\u003eLenze ELN3-0120H017\u003c\/strong\u003e three-phase mains choke reduces mains harmonics and limits commutation spikes. This line reactor acts as an inductive impedance in the mains supply line, protecting upstream frequency inverters and sensitive electronic components from transient overvoltages and grid disturbances. By smoothing the current waveform, the \u003cstrong\u003eELN3-0120H017\u003c\/strong\u003e significantly reduces the RMS value of the mains current, lowering thermal load on cables and distribution equipment while improving the overall power factor of the system.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReduces harmonic distortion (THDi) in compliance with international power quality standards.\u003c\/li\u003e\n  \u003cli\u003eLimits mains current peaks and voltage spikes to protect inverter input rectifiers.\u003c\/li\u003e\n  \u003cli\u003eOptimized for integration with Lenze frequency inverters and drive controllers.\u003c\/li\u003e\n  \u003cli\u003eThree-phase design engineered for continuous industrial operation.\u003c\/li\u003e\n  \u003cli\u003eCompact footprint allows for space-saving mounting inside control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFrequency inverter mains buffering in automated production lines.\u003c\/li\u003e\n  \u003cli\u003eIndustrial motor control centers and machine tool manufacturing.\u003c\/li\u003e\n  \u003cli\u003ePumping, ventilation, and air conditioning (HVAC) systems.\u003c\/li\u003e\n  \u003cli\u003ePower quality improvement in weak or unstable electrical grids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eELN3-0120H017\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eELN3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMains Choke \/ Line Reactor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Phases\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3-phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e17 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Inductance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.2 mH\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 480 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMains Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Designation\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1U1 \/ 1V1 \/ 1W1\u003c\/td\u003e\n      \u003ctd\u003eMains Input Connection (L1, L2, L3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1U2 \/ 1V2 \/ 1W2\u003c\/td\u003e\n      \u003ctd\u003eLoad Output Connection to Inverter (U, V, W)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePE\u003c\/td\u003e\n      \u003ctd\u003eProtective Earth Connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Mount vertically on a flat, thermally conductive surface to ensure optimal natural convection and heat dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm above and below the unit to prevent thermal blockages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure a low-impedance PE connection directly to the control cabinet mounting plate.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route input mains cables and output cables to the inverter separately to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050419563,"sku":"ELN3-0120H017","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/eln3-0120h017-k2bdptp41yx.png?v=1776236267"},{"product_id":"lenze-e82zafcc200-8200-series-communication-module","title":"Lenze E82ZAFCC200 8200-series Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for integration with the Lenze 8200 vector frequency inverters, the \u003cstrong\u003eE82ZAFCC200\u003c\/strong\u003e serves as a specialized \u003cstrong\u003eCAN-I\/O communication module\u003c\/strong\u003e to facilitate decentralized fieldbus networking. This function module mounts directly onto the inverter's standard interface slot, enabling real-time data exchange, parameterization, and control command transmission via the CAN system bus. By integrating this module, operators can seamlessly connect their drive systems to centralized PLCs or distributed control networks, optimizing system response times and reducing wiring complexity in automated environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect plug-in mounting onto Lenze 8200 vector frequency inverters.\u003c\/li\u003e\n  \u003cli\u003eIntegrated CAN system bus interface for decentralized automation architectures.\u003c\/li\u003e\n  \u003cli\u003eSupports standard CAN communication protocols for multi-vendor system compatibility.\u003c\/li\u003e\n  \u003cli\u003eEnables remote parameter configuration, diagnostics, and real-time control of the drive.\u003c\/li\u003e\n  \u003cli\u003eCompact form factor designed for space-saving installation within the drive housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis communication module is widely utilized in industrial automation environments, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConveyor and material handling systems\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery\u003c\/li\u003e\n  \u003cli\u003eAutomated production lines\u003c\/li\u003e\n  \u003cli\u003eMachine tool integration utilizing Lenze 8200 vector drives\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE82ZAFCC200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8200-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCAN-I\/O Communication Function Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.05 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85044086\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze 8200 Vector Inverters\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor safe and reliable operation, adhere to the following engineering guidelines during installation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the frequency inverter is completely powered down and the DC-bus capacitors are fully discharged before inserting or removing the module.\u003c\/li\u003e\n  \u003cli\u003ePlug the E82ZAFCC200 module firmly into the dedicated function slot on the front of the 8200 vector inverter.\u003c\/li\u003e\n  \u003cli\u003eSecure the module using the integrated retaining screws to ensure reliable electrical contact and vibration resistance.\u003c\/li\u003e\n  \u003cli\u003eRoute CAN bus cabling away from high-voltage motor cables to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003eEnsure proper termination resistors (120 ohms) are installed at both physical ends of the CAN network segment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050517867,"sku":"E82ZAFCC200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafcc200-t4cotbuf4ot.png?v=1776235971"},{"product_id":"lenze-evf8244-e-8200-series-ac-drive","title":"Lenze EVF8244-E 8200-series AC Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for precise speed and torque regulation of three-phase asynchronous motors, the Lenze EVF8244-E frequency inverter provides robust control within the 8200-series architecture. This high-performance AC drive is designed to optimize energy consumption and maintain process stability in demanding industrial automation environments, supporting motors rated up to \u003cstrong\u003e4 HP (3.0 kW) at 460V\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Motor Management:\u003c\/strong\u003e Advanced electronic control algorithms ensure stable speed control and dynamic torque response under varying load conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Design:\u003c\/strong\u003e Seamlessly integrates with various plug-in communication and I\/O modules from the Lenze 8200 range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e Optimizes motor power consumption during partial-load operations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Built to withstand harsh industrial environments, ensuring long-term operational reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eConveyor systems and material handling lines\u003c\/li\u003e\n  \u003cli\u003eIndustrial pumps, fans, and ventilation systems\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and processing equipment\u003c\/li\u003e\n  \u003cli\u003eMachine tool auxiliary drives and positioning systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eEVF8244-E\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAlternative Item Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e33.8244_E\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8200-series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAC Drive \/ Frequency Inverter\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3.0 kW \/ 4.0 HP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Input Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3-phase 400 V AC to 460 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePhase-Out (Legacy Support Available)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10.20 cm x 40.60 cm x 25.40 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5.10 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe EVF8244-E belongs to the legacy 8200 Vector family. When replacing this unit in existing panels, note that modern alternatives like the Lenze i550 series do not share the same physical footprint or terminal configurations. Retaining exact spares like the EVF8244-E avoids costly mechanical panel modifications and PLC program rewrites.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis drive relies heavily on vertical convection cooling. In enclosed control panels, ensure a minimum clearance of 100 mm above and below the unit. If ambient temperatures inside the enclosure exceed 40 degC, the continuous output current must be derated to prevent thermal overload faults.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eParameterization can be performed using the EMZ8201BB keypad module or via the LECOM interface using Global Drive Control (GDC) software. Always ensure that the motor cable is shielded and that the shield is grounded with a low-impedance connection directly at the drive's mounting plate to mitigate electromagnetic interference (EMI).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous electrical voltages remain present in the DC bus capacitors (terminals UG and +UG) for up to 5 minutes after disconnecting the mains supply. Verify that the DC bus voltage has discharged to 0 VDC using a calibrated multimeter before performing any wiring, terminal modifications, or maintenance.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the drive vertically on a flat, vibration-free mounting plate inside a suitable industrial enclosure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the protective earth (PE) conductor to the designated grounding terminal prior to making any other electrical connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the 3-phase AC mains input to terminals L1, L2, and L3 using appropriately sized branch circuit protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the shielded motor cable to output terminals U, V, and W, ensuring the shield clamp is securely fastened to the ground plane.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050583403,"sku":"EVF8244-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evf8244-e-qumgege13ih.png?v=1776236448"},{"product_id":"lenze-e84avsce1134sx0-8400-series-variable-frequency-drive","title":"Lenze E84AVSCE1134SX0 8400 Series Variable Frequency Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to optimize motor control efficiency in complex industrial systems, the \u003cstrong\u003eLenze E84AVSCE1134SX0\u003c\/strong\u003e variable frequency drive provides precise speed and torque regulation for three-phase asynchronous motors. This 8400 Series inverter module features integrated interference suppression measures to ensure electromagnetic compatibility and stable operation within crowded electrical cabinets. Engineered for direct panel mounting, the unit combines a compact footprint with robust thermal management to maintain high performance under continuous heavy-duty industrial loads.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIntegrated interference suppression filters to minimize high-frequency electromagnetic emissions.\u003c\/li\u003e\n  \u003cli\u003eSpace-saving book-style design optimized for side-by-side control cabinet installation.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in safety functionality supporting Safe Torque Off (STO) configurations.\u003c\/li\u003e\n  \u003cli\u003eHigh overload capacity suitable for demanding starting torques and dynamic duty cycles.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Lenze L-force software suite for rapid commissioning and parameter cloning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial conveyor networks and automated material handling systems.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal pumps, industrial fans, and HVAC ventilation control.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery, rotary tables, and cyclic drive systems.\u003c\/li\u003e\n  \u003cli\u003eGeneral machine tool manufacturing and assembly line automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eE84AVSCE1134SX0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8400 StateLine\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRated Power Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e11.0 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMains Connection Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3 AC 400 V \/ 500 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMains Frequency Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e45 to 65 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEnclosure Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePermissible Operating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to +55 degC (with derating above +45 degC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Dimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e350 x 135 x 250 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Product Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e6.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eL1, L2, L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3-Phase Mains AC Power Input Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eU, V, W\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eControlled AC Output to Motor Stator\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e+UG, -UG\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDC Bus Terminals (for shared DC bus or braking unit connection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eControl Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAnalog Inputs\/Outputs, Digital Inputs\/Outputs, and Relay Contacts\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E84AVSCE1134SX0 belongs to the 8400 StateLine family. When replacing older 8200 vector series drives or alternative 8400 variants (such as BaseLine or HighLine), verify that the control terminal configuration matches. Parameter sets can be migrated using the Lenze L-force Engineer software, but firmware revision differences (e.g., V1.x to V2.x) may require manual adjustment of specific register mappings.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IP20 open-chassis design relies heavily on convection cooling. When mounting multiple units side-by-side in a single enclosure, ensure a minimum vertical clearance of 100 mm above and below the drive. Operating the unit continuously at 11 kW near its upper thermal limit of +55 degC requires external cabinet ventilation or active air conditioning to prevent overtemperature faults.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use low-capacitance, shielded motor cables. The shield must be grounded over a large surface area using the integrated EMC shield plate on the drive housing. To prevent high-frequency common-mode currents from interfering with sensitive analog control loops, ensure the control cables are routed separately from the high-voltage motor and mains power lines.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDANGER: Hazardous electrical charge remains stored in the internal DC-bus capacitors after the mains supply is disconnected. Wait at least 10 minutes after complete physical de-energization and verify that the voltage between the +UG and -UG terminals is below 50 VDC before initiating any installation, wiring, or maintenance procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the drive vertically on a flat, vibration-free backplate inside an IP54 or higher rated control cabinet, ensuring the cooling fins are unobstructed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the protective earth (PE) conductor to the designated grounding terminal block prior to making any other electrical connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the 3-phase mains input power to terminals L1, L2, and L3, and wire the motor output lines to terminals U, V, and W using specified torque values.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the control and safety (STO) wiring, ensuring proper shielding and separation from power cabling before applying power for commissioning.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050681707,"sku":"E84AVSCE1134SX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e84avsce1134sx0-lxb3k02zn54.png?v=1776236100"},{"product_id":"lenze-e84avsce2224sx0-8400-series-variable-frequency-drive","title":"Lenze E84AVSCE2224SX0 8400 Series Variable Frequency Drive","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEfficient motor control and system reliability are central to the design of the \u003cstrong\u003eE84AVSCE2224SX0\u003c\/strong\u003e variable frequency drive. This high-performance inverter module from the \u003cstrong\u003eLenze 8400 Series\u003c\/strong\u003e is engineered to regulate three-phase asynchronous motors in demanding industrial automation environments. Featuring integrated interference suppression measures, this drive minimizes electromagnetic disturbances, ensuring seamless integration into complex production lines without compromising signal integrity. Operating with a mains voltage configuration of 3 x 400 \/ 500 V AC and delivering a rated power of 2.2 kW, it provides precise speed and torque control for various machinery applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated interference suppression measures (EMC filter) to reduce electromagnetic emissions.\u003c\/li\u003e\n\u003cli\u003eDesigned for three-phase mains connection (3 x 400 \/ 500 V AC).\u003c\/li\u003e\n\u003cli\u003eRated power output of 2.2 kW optimized for standard industrial motors.\u003c\/li\u003e\n\u003cli\u003eCompact bookstyle design for space-saving control cabinet installation.\u003c\/li\u003e\n\u003cli\u003ePart of the scalable Lenze 8400 drive family, supporting modular communication and functional safety options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConveyor systems and material handling.\u003c\/li\u003e\n\u003cli\u003ePumps, fans, and ventilation systems.\u003c\/li\u003e\n\u003cli\u003ePackaging machinery and production lines.\u003c\/li\u003e\n\u003cli\u003eGeneral machine tool automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE84AVSCE2224SX0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8400 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVariable Frequency Drive (Inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 400 \/ 500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterference Suppression\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 mm x 140 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount vertically on a flat, thermally conductive mounting plate inside a control cabinet.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate clearance above and below the unit for natural convection or forced cooling.\u003c\/li\u003e\n\u003cli\u003eUse shielded motor cables to maintain EMC compliance and connect the shield to the ground PE rail with low impedance.\u003c\/li\u003e\n\u003cli\u003eVerify that the mains supply voltage matches the nominal rating (3 x 400\/500 V AC) before energizing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105051894123,"sku":"E84AVSCE2224SX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e84avsce2224sx0-zh0cjjf5sw3.png?v=1776236099"},{"product_id":"lenze-evs9326-esv004-9300-series-servo-drive","title":"Lenze EVS9326-ESV004 9300-Series Servo Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOperating as a core component within industrial motion control architectures, the \u003cstrong\u003eLenze EVS9326-ESV004\u003c\/strong\u003e is a high-performance \u003cstrong\u003eservo inverter\u003c\/strong\u003e designed for precise speed, torque, and position control. Part of the established \u003cstrong\u003e9300-Series\u003c\/strong\u003e, this unit provides reliable vector control and servo functionality for demanding automation systems. It features an IP20 protection rating, making it suitable for control cabinet installation where space optimization and thermal management are critical. The controller supports complex motion profiles and integrates seamlessly with standard industrial communication networks and feedback systems to ensure closed-loop accuracy.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated power output of 11.0 kW for heavy-duty industrial drive applications.\u003c\/li\u003e\n  \u003cli\u003eIntegrated IP20-rated enclosure designed for clean, dry control cabinet environments.\u003c\/li\u003e\n  \u003cli\u003ePart of the legacy Lenze 9300-Series ecosystem, ensuring compatibility with existing system architectures.\u003c\/li\u003e\n  \u003cli\u003eCompact mechanical footprint to maximize cabinet space efficiency.\u003c\/li\u003e\n  \u003cli\u003eSupports precise dynamic response and high-accuracy speed\/torque regulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePackaging machinery and automated wrapping systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, conveyors, and gantry positioning systems.\u003c\/li\u003e\n  \u003cli\u003ePrinting and paper processing machinery.\u003c\/li\u003e\n  \u003cli\u003eGeneral industrial machine tool axes requiring precise servo control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEVS9326-ESV004\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9300-Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eServo Drive \/ Inverter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11.0 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35.00 x 25.00 x 13.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install vertically inside a control cabinet to ensure optimal convection cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain recommended top and bottom clearances for unobstructed airflow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Ensure the installation environment remains within non-condensing limits and does not exceed the rated operating temperature.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded motor cables to minimize electromagnetic interference (EMI) and ensure proper system grounding.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105051992427,"sku":"EVS9326-ESV004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9326-esv004-4ejkyw4s5oe.png?v=1776236694"},{"product_id":"lenze-e94azps0074-9400-series-installation-backplane","title":"Lenze E94AZPS0074 9400-series Installation Backplane","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for mechanical and electrical integration within modular drive systems, the \u003cstrong\u003eLenze E94AZPS0074\u003c\/strong\u003e serves as a dedicated \u003cstrong\u003einstallation backplane\u003c\/strong\u003e for Single Drive Size 2 controllers. This backplane simplifies control cabinet assembly by providing a secure mounting foundation and reliable interface connections for the Lenze 9400 HighLine servo drive series. Engineered for configurations that do not require an integrated brake module, it ensures streamlined wiring, robust mechanical stability, and efficient heat dissipation within the enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered specifically for Lenze 9400-series Single Drive Size 2 modules.\u003c\/li\u003e\n  \u003cli\u003eDesigned for configurations without an integrated brake module.\u003c\/li\u003e\n  \u003cli\u003eSimplifies cabinet installation and reduces wiring complexity.\u003c\/li\u003e\n  \u003cli\u003eEnables rapid module replacement for minimized system downtime.\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical construction suitable for demanding industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial motion control and servo drive systems.\u003c\/li\u003e\n  \u003cli\u003eAutomated packaging and processing machinery.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eTextile manufacturing equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eParameter\u003c\/strong\u003e\n      \u003cstrong\u003eValue\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003eE94AZPS0074\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003e9400-series (9400 HighLine)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eInstallation Backplane (Digital Module)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCompatible Drive Size\u003c\/td\u003e\n      \u003ctd\u003eSize 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBrake Module Configuration\u003c\/td\u003e\n      \u003ctd\u003eWithout brake module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e1.59 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the backplane vertically on a flat, conductive, and grounded mounting plate inside the control cabinet to ensure proper electromagnetic compatibility (EMC).\u003c\/li\u003e\n  \u003cli\u003eEnsure all mounting screws are tightened to the manufacturer's specified torque to maintain mechanical integrity.\u003c\/li\u003e\n  \u003cli\u003eVerify that the drive controller size matches the backplane size (Size 2) before attempting insertion.\u003c\/li\u003e\n  \u003cli\u003eMaintain recommended clearance distances above and below the unit to facilitate adequate convective airflow and cooling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052057963,"sku":"E94AZPS0074","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e94azps0074-wnes25x55ri.png?v=1776236231"},{"product_id":"lenze-e94azps0074n-9400-series-mounting-base","title":"Lenze E94AZPS0074N 9400-series Mounting Base","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned to provide a secure and reliable mechanical foundation, the \u003cstrong\u003eE94AZPS0074N\u003c\/strong\u003e serves as a dedicated mounting base for Lenze \u003cstrong\u003e9400-series\u003c\/strong\u003e control modules. This component facilitates stable installation and seamless integration of control electronics within industrial drive systems and electrical cabinets. Its robust construction ensures vibration resistance and precise alignment, protecting sensitive control interfaces from mechanical stress.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for high-density control cabinets, this mounting base optimizes space while maintaining easy access for wiring and maintenance. It supports efficient system assembly and modular component swapping, minimizing downtime during system upgrades or servicing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSpecifically engineered for compatibility with Lenze 9400-series control modules.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight design to maximize cabinet space efficiency.\u003c\/li\u003e\n  \u003cli\u003eHigh-quality mechanical construction ensuring long-term durability in demanding industrial environments.\u003c\/li\u003e\n  \u003cli\u003eFacilitates quick and secure mounting of control electronics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial drive systems and cabinet installations.\u003c\/li\u003e\n  \u003cli\u003eAutomated production lines utilizing Lenze 9400 servo systems.\u003c\/li\u003e\n  \u003cli\u003eMachine building and factory automation control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE94AZPS0074N\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9400-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMounting Base \/ Control Module Accessory\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.30 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85044088\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the base securely to the DIN rail or backplate before attaching the control module.\u003c\/li\u003e\n  \u003cli\u003eEnsure adequate clearance around the unit to allow proper ventilation and cooling of the attached control module.\u003c\/li\u003e\n  \u003cli\u003eAlign the control module carefully with the guide rails of the E94AZPS0074N and press firmly until the locking mechanism fully engages.\u003c\/li\u003e\n  \u003cli\u003eVerify all mechanical connections are tight and secure to prevent vibration-induced wear.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052156267,"sku":"E94AZPS0074N","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e94azps0074n-zfn355tzilz.png?v=1776236243"},{"product_id":"e82ev752-4c040","title":"Lenze E82EV752_4C040 8200 Vector Frequency Inverter","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for precise speed and torque regulation of three-phase asynchronous motors, the \u003cstrong\u003eLenze E82EV752_4C040\u003c\/strong\u003e frequency inverter serves as a core control component within the \u003cstrong\u003e8200 Vector\u003c\/strong\u003e series. This modular drive is designed to optimize energy consumption and mechanical wear across diverse industrial drive architectures, offering robust performance under varying load conditions.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Performance Vector Control:\u003c\/strong\u003e Delivers exceptional dynamic response and high torque output even at low rotational speeds.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eModular Interface Architecture:\u003c\/strong\u003e Supports plug-in communication modules for seamless integration into standard fieldbus networks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIntegrated Interference Suppression:\u003c\/strong\u003e Built-in filters comply with standard industrial electromagnetic compatibility (EMC) requirements.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Advanced heatsink design ensures reliable heat dissipation under continuous duty cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eConveyor and material handling systems requiring controlled acceleration and deceleration.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCentrifugal pumps and industrial ventilation fans utilizing variable flow control.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003ePackaging machinery and processing lines requiring synchronized speed matching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eE82EV752_4C040 (E82EV752K4C040)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8200 Vector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Power Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7.5 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3-Phase 400V to 500V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePhase-Out (Legacy Support Available)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85044090\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eExport Control Classification (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3.82 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e15.00 x 6.00 x 10.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E82EV752_4C040 is fully compatible with other 8200 Vector drives of the same frame size. When replacing legacy units, ensure that the plug-in function module (such as the standard I\/O module or fieldbus interface card) is transferred to the new drive, as base units are shipped without control terminals.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIn enclosed control cabinets, this 7.5 kW unit generates significant thermal dissipation. Maintain a minimum vertical clearance of 100 mm above and below the chassis to prevent overtemperature faults (fault code OH). If operating continuously at 500V AC, verify that the motor insulation class is rated for high-peak voltage reflections.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways utilize low-capacitance, shielded motor cables. The shield must be grounded with a large surface area contact directly at the drive's functional earth plate to prevent high-frequency leakage currents from disrupting nearby analog instrumentation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources before commencing installation. Wait a minimum of 5 minutes after complete de-energization to allow the internal DC-bus capacitors to discharge to safe voltage levels (\u0026lt; 50 VDC) before touching terminals.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; margin-right: 10px; font-weight: bold; font-size: 14px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eMount the drive vertically on a flat, vibration-free backplate inside an IP54 or higher rated enclosure.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; margin-right: 10px; font-weight: bold; font-size: 14px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eConnect the protective earth (PE) conductor to the designated grounding terminal block.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; margin-right: 10px; font-weight: bold; font-size: 14px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eWire the 3-phase AC mains supply to terminals L1, L2, and L3 using appropriate branch circuit protection.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; margin-right: 10px; font-weight: bold; font-size: 14px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eConnect the shielded motor cable to terminals U, V, and W, ensuring the shield is grounded at both ends.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; margin-right: 10px; font-weight: bold; font-size: 14px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eInsert the required communication or standard I\/O module into the front interface slot prior to powering up.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052254571,"sku":"E82EV752_4C040","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev752-4c040-huwwf3o5qvl.png?v=1776235921"},{"product_id":"lenze-e82zafsc001-8200-vector-standard-i-o-function-module","title":"Lenze E82ZAFSC001 8200 Vector Standard I\/O Function Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegrating control signals into the Lenze 8200 Vector frequency inverter series is facilitated by the \u003cstrong\u003eE82ZAFSC001\u003c\/strong\u003e standard I\/O function module. This pluggable accessory expands the base drive's control topology, providing dedicated analog and digital interfaces for system integration. Designed as a modular expansion component, it mounts directly onto the front interface slot of the 8200 Vector inverter, enabling direct communication with external PLC systems, sensors, and actuators without requiring external bus systems.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eE82ZAFSC001\u003c\/strong\u003e is engineered for legacy system maintenance and retrofitting, offering a reliable solution for applications requiring hardwired analog and digital control loops. Its compact form factor ensures that the drive's overall footprint remains unchanged when the module is installed.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePluggable design for direct mounting on Lenze 8200 Vector frequency inverters.\u003c\/li\u003e\n  \u003cli\u003eExpands control terminal capabilities with standard analog and digital inputs\/outputs.\u003c\/li\u003e\n  \u003cli\u003eHost-powered directly from the drive's internal control voltage supply.\u003c\/li\u003e\n  \u003cli\u003eCompact form factor optimized for space-constrained control cabinet enclosures.\u003c\/li\u003e\n  \u003cli\u003eScrew terminal connections for secure field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRetrofitting and maintenance of legacy Lenze 8200 Vector drive systems.\u003c\/li\u003e\n  \u003cli\u003eFactory automation systems requiring basic hardwired I\/O control.\u003c\/li\u003e\n  \u003cli\u003ePumping, ventilation, and conveyor systems utilizing localized speed control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003eE82ZAFSC001\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003e8200 Vector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Type\u003c\/strong\u003e\n      \u003ctd\u003eStandard I\/O Function Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDimensions\u003c\/strong\u003e\n      \u003ctd\u003e5.10 cm x 6.30 cm x 2.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.05 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCommodity Code\u003c\/strong\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eLifecycle Status\u003c\/strong\u003e\n      \u003ctd\u003ePhase-out (Legacy component)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e7\u003c\/td\u003e\n      \u003ctd\u003eAnalog input (0-10 V, 0\/4-20 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n      \u003ctd\u003eAnalog output (0-10 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e9\u003c\/td\u003e\n      \u003ctd\u003eInternal DC voltage supply (+24 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003eDigital input 1 (Start\/Stop)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003eDigital input 2 (Parameter set selection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e39\u003c\/td\u003e\n      \u003ctd\u003eGND \/ Reference potential\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e62\u003c\/td\u003e\n      \u003ctd\u003eDigital output 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the frequency inverter is completely powered down and the DC bus capacitors are fully discharged before inserting or removing the module.\u003c\/li\u003e\n  \u003cli\u003eAlign the module pins with the front interface slot of the 8200 Vector inverter and press firmly until it clicks into place.\u003c\/li\u003e\n  \u003cli\u003eSecure control wiring using shielded cables to prevent electromagnetic interference (EMI) from the motor cables.\u003c\/li\u003e\n  \u003cli\u003eRoute control cables separately from high-voltage power cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052352875,"sku":"E82ZAFSC001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafsc001-ycpx5nucxhw.png?v=1776236037"},{"product_id":"lenze-e82ev371-2b-8200-vector-variable-frequency-drive","title":"Lenze E82EV371_2B 8200 Vector Variable Frequency Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding precise speed and torque control for industrial three-phase motors, the \u003cstrong\u003eLenze E82EV371_2B\u003c\/strong\u003e is a modular frequency inverter designed for high-efficiency operation within automated architectures. This unit, belonging to the respected \u003cstrong\u003e8200 Vector\u003c\/strong\u003e series, delivers a rated power output of \u003cstrong\u003e0.37 kW\u003c\/strong\u003e and features integrated interference suppression measures to maintain electromagnetic compatibility in demanding electrical environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eIntegrated radio frequency interference (RFI) suppression filters to minimize electrical noise.\u003c\/li\u003e\n  \u003cli\u003eVector control processing for optimized torque characteristics at low rotational speeds.\u003c\/li\u003e\n  \u003cli\u003eModular interface slot allowing seamless integration of fieldbus communication modules.\u003c\/li\u003e\n  \u003cli\u003eCompact physical footprint designed for space-optimized control cabinet layouts.\u003c\/li\u003e\n  \u003cli\u003eRobust thermal management and protection circuits against overvoltage, undervoltage, and motor overload.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eMaterial handling systems and small conveyor belts.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and labeling systems.\u003c\/li\u003e\n  \u003cli\u003eIndustrial fan and centrifugal pump speed regulation.\u003c\/li\u003e\n  \u003cli\u003eAuxiliary machine tool positioning and feed drives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Reference\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eE82EV371_2B (E82EV371K2B)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8200 Vector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMains Connection Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3 x 230 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Power Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.37 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterference Suppression\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIntegrated filter measures\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePhase-Out (Legacy support active)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e6.00 x 14.00 x 12.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.80 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eExport Control Classification\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eECCN: N\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal Designation\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eL1, L2, L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3-Phase AC Mains Input Connection (230 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eU, V, W\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3-Phase Motor Output Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePE\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eProtective Earth Grounding Terminal\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E82EV371_2B is functionally identical to the model reference E82EV371K2B, where the \"K\" designates the decimal placement for its 0.37 kW rating. When replacing older 8200 series units, ensure that any pluggable communication modules (such as CANopen or PROFIBUS FIF modules) are retained and transferred to the replacement unit, as the base power module does not include communication interfaces by default.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this VFD is in its legacy phase-out lifecycle, thermal management is critical when retrofitting older enclosures. Ensure a minimum clearance of 100 mm above and below the drive to prevent heat buildup, as the internal heatsink relies heavily on unobstructed vertical convection currents.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo maintain the effectiveness of the integrated interference suppression filter, always use low-capacitance shielded motor cables. The shield must be grounded with a 360-degree metal clamp directly to the mounting plate as close to the drive's PE terminal as possible to minimize high-frequency electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources before commencing installation or maintenance. After disconnecting the mains supply, wait at least 5 minutes for the internal DC-bus capacitors to discharge completely to safe voltage levels before touching any electrical terminals.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the drive vertically on a flat, conductive, and grounded metal mounting plate inside an IP54 or higher rated control cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the protective earth (PE) conductor to the designated grounding terminal before making any other wiring connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the 3-phase 230 V AC mains input to terminals L1, L2, and L3, and the motor leads to terminals U, V, and W using shielded cables.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052451179,"sku":"E82EV371_2B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev371-2b-mvtpq5mlqfk.png?v=1776235843"},{"product_id":"lenze-evs9327-esv004-9300-series-servo-drive","title":"Lenze EVS9327-ESV004 9300-Series Servo Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-performance motion control, the \u003cstrong\u003eLenze EVS9327-ESV004\u003c\/strong\u003e is a robust \u003cstrong\u003eservo inverter\u003c\/strong\u003e engineered to deliver precise speed, torque, and position control within complex industrial automation systems. This \u003cstrong\u003e9300-Series\u003c\/strong\u003e controller is optimized for demanding dynamic applications, offering seamless integration with various feedback systems and fieldbus communication options. Operating with a rated power of 15.0 kW, this unit ensures reliable power delivery and high efficiency in continuous-duty cycles. Its compact mechanical design minimizes control cabinet space requirements while maintaining excellent thermal performance.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-precision dynamic response for complex motion profiles and multi-axis synchronization.\u003c\/li\u003e\n  \u003cli\u003eRated power output of 15.0 kW to handle heavy-duty industrial loads.\u003c\/li\u003e\n  \u003cli\u003eIP20 protection rating designed specifically for secure control cabinet installation.\u003c\/li\u003e\n  \u003cli\u003eIntegrated system bus interfaces for streamlined communication and configuration.\u003c\/li\u003e\n  \u003cli\u003eRobust thermal management to ensure operational stability under varying load conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePackaging machinery and automated wrapping systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, conveying, and gantry positioning systems.\u003c\/li\u003e\n  \u003cli\u003eTextile manufacturing and processing equipment.\u003c\/li\u003e\n  \u003cli\u003ePrinting, paper converting, and winding machines.\u003c\/li\u003e\n  \u003cli\u003eGeneral machine tool automation and rotary indexing tables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eEVS9327-ESV004\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003e9300-Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Type\u003c\/strong\u003e\n      \u003ctd\u003eServo Drive \/ Servo Inverter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eRated Power\u003c\/strong\u003e\n      \u003ctd\u003e15.0 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProtection Class\u003c\/strong\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Phase\u003c\/strong\u003e\n      \u003ctd\u003ePhase-Out (Legacy Support Available)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\n      \u003ctd\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e12.50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\n      \u003ctd\u003e35.00 x 25.00 x 25.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCommodity Code\u003c\/strong\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure safe and reliable operation of the EVS9327-ESV004 servo drive, adhere to the following engineering guidelines during installation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Install the unit vertically in the control cabinet to facilitate natural convection cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e Maintain the manufacturer-specified minimum clearances above and below the drive to prevent heat accumulation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Use high-quality shielded cables for all motor connections and control lines. Ensure a low-impedance PE connection to the mounting plate to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Conditions:\u003c\/strong\u003e Ensure the ambient operating temperature does not exceed the specified limits and that the cabinet is free from conductive dust and corrosive gases.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052647787,"sku":"EVS9327-ESV004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9327-esv004-qydlf3mw3nf.png?v=1776236713"},{"product_id":"lenze-e82ev371-2c200-8200-vector-variable-frequency-drive","title":"Lenze E82EV371_2C200 8200 Vector Variable Frequency Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for precise motor speed control in space-constrained automation panels, the \u003cstrong\u003eLenze E82EV371_2C200\u003c\/strong\u003e is a 0.37 kW basic frequency inverter belonging to the legacy \u003cstrong\u003e8200 Vector\u003c\/strong\u003e series. This single-phase unit provides reliable vector control performance for standard three-phase asynchronous motors, offering a compact footprint and modular adaptability for industrial machinery.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle-Phase Input:\u003c\/strong\u003e Optimized for 1-phase AC mains operation, making it suitable for localized or utility-level industrial power grids.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFilterless Design:\u003c\/strong\u003e Basic unit variant supplied without an integrated EMC filter, allowing custom external filtering configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e Compatible with pluggable 8200-series function modules for communication and expanded I\/O.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Torque Performance:\u003c\/strong\u003e Vector control capability ensures stable torque output even at low rotational speeds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Conveyor belts, sorting tables, and small feeder drives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFluid Control:\u003c\/strong\u003e Small centrifugal pumps and localized ventilation fans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e Auxiliary axes, labeling machines, and wrapping systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine Tools:\u003c\/strong\u003e Speed regulation for small spindle drives and tool feeds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eE82EV371_2C200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAlternative Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eE82EV371K2C200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8200-series (8200 Vector)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eVariable Frequency Drive (VFD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.37 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Phases\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1-Phase (1~ AC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eIntegrated EMC Filter\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eNone (Variant without integrated filter)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePhase-Out (Legacy support available)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e6.10 x 12.70 x 14.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eTerminal Designation\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eL1, N\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSingle-Phase AC Mains Input Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eU, V, W\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3-Phase Motor Output Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePE\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eProtective Earth Grounding Terminal\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  \u003cstrong\u003eAlternative Models \u0026amp; Compatibility:\u003c\/strong\u003e The E82EV371_2C200 is functionally identical to the model listed under the SKU E82EV371K2C200, where the \"K\" designates the decimal placement for the 0.37 kW power rating. When replacing older 8200 series units, ensure that any existing pluggable communication modules (such as LECOM or CANopen) are carefully migrated to the new basic unit, as these modules are hot-swappable but require proper parameter mapping upon first power-up.\n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  \u003cstrong\u003eApplication Pitfalls \u0026amp; Engineering Notes:\u003c\/strong\u003e Because this specific variant does not feature an integrated EMC filter, it is highly susceptible to emitting high-frequency electromagnetic interference back into the mains supply. If installing this unit in environments sensitive to electrical noise (such as laboratory or light industrial zones), an external mains filter must be wired in series with the input power lines.\n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong\u003eCommissioning \u0026amp; Wiring Tips:\u003c\/strong\u003e Ensure that the motor cable is shielded and grounded at both ends with low-impedance connections. When configuring parameters via the keypad or Global Drive Control (GDC) software, verify that the motor nameplate data matches the drive's default motor parameters to prevent overcurrent faults (OC1) during initial acceleration ramps.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Ensure all input power sources are completely de-energized and locked out before attempting installation or wiring. Wait at least 5 minutes after disconnecting power to allow internal DC bus capacitors to discharge to safe voltage levels (less than 50 VDC) before touching any terminals.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv\u003eMount the drive vertically on a flat, vibration-free surface inside an IP54 or appropriate industrial enclosure to protect against dust and moisture ingress.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv\u003eMaintain a minimum clearance of 100 mm above and below the unit to facilitate natural convection cooling and prevent thermal derating.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv\u003eConnect the single-phase AC mains supply to terminals L1 and N, ensuring correct fuse ratings are applied in accordance with local electrical codes.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv\u003eWire the 3-phase motor cables to terminals U, V, and W, ensuring the protective ground (PE) is securely bonded to the main system ground bus.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052713323,"sku":"E82EV371_2C200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev371-2c200-10np2jc2xya.png?v=1776235866"},{"product_id":"lenze-9400-series-e94amhe0174-servo-drive","title":"Lenze 9400-Series E94AMHE0174 Servo Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eE94AMHE0174\u003c\/strong\u003e is a high-performance \u003cstrong\u003emulti-drive servo unit\u003c\/strong\u003e from the \u003cstrong\u003eLenze 9400-Series\u003c\/strong\u003e, engineered for precise, high-speed motion control in multi-axis industrial automation systems. With a rated power of \u003cstrong\u003e7.5 kW\u003c\/strong\u003e and a wide DC supply range (260–775 V), this unit is designed for stable and efficient operation in demanding environments. As a member of the active 9400-series product line, it supports advanced diagnostics, seamless commissioning, and flexible integration with modern network protocols.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Drive Architecture:\u003c\/strong\u003e Optimized for synchronized multi-axis control applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Power Input:\u003c\/strong\u003e Wide DC supply range (260–775 V) with a nominal DC voltage of 565 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency:\u003c\/strong\u003e Advanced electronic design ensures reliable, energy-efficient performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Status:\u003c\/strong\u003e Fully supported, current-production unit for modern industrial integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Optimized dimensions (24.00 x 14.00 x 12.50 cm) for efficient control panel space utilization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e9400-series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Drive (Multi Drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e260–775 V (Nominal 565 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24.00 x 14.00 x 12.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install vertically within the control cabinet, ensuring that airflow is unobstructed to maximize the effectiveness of the internal cooling system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Ensure the control cabinet is shielded from moisture, conductive dust, and extreme temperature fluctuations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the DC bus system according to the multi-axis architecture specifications. Use high-quality shielded cabling for motor and feedback signals to meet EMC standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Strictly observe the DC bus discharge time before accessing internal components. Use the LOTO (Lock-Out\/Tag-Out) procedure for maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Utilize the Lenze engineering tools (e.g., EASY Starter) for motor parameterization and fieldbus configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052778859,"sku":"E94AMHE0174","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e94amhe0174-rdrvym3hde4.png?v=1776236113"},{"product_id":"lenze-9300-series-evs9322-esv004-servo-inverter","title":"Lenze 9300-Series EVS9322-ESV004 Servo Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEVS9322-ESV004\u003c\/strong\u003e is a specialized \u003cstrong\u003eservo inverter\u003c\/strong\u003e from the reputable \u003cstrong\u003eLenze 9300-Series\u003c\/strong\u003e. Designed for high-precision motion control, this unit is rated for \u003cstrong\u003e0.75 kW\u003c\/strong\u003e, making it ideal for compact, high-accuracy applications in automated production lines. It features an IP20 protection rating and is engineered for reliable performance within control cabinets. As part of the 9300-Series, it offers excellent connectivity and compatibility with industrial communication protocols, ensuring it integrates effectively into modular automation architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Precision Control:\u003c\/strong\u003e Excellent speed, torque, and position regulation suitable for demanding motion tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Power:\u003c\/strong\u003e 0.75 kW rated output in a small, efficient form factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP20 Protection:\u003c\/strong\u003e Robust housing for protected, cabinet-based industrial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Communication:\u003c\/strong\u003e Compatible with standard industrial protocols for seamless system integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven Reliability:\u003c\/strong\u003e A cornerstone of the 9300-Series lineup, supporting stable and accurate motion control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e9300-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.00 x 25.00 x 7.80 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the drive vertically on a standard DIN rail or mounting plate within a control cabinet to allow for proper airflow across the heat sink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Ensure the cabinet has adequate ventilation to maintain operating temperatures within the manufacturer's specified limits for electronic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cabling for both the motor output and the feedback encoder signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Connect the fieldbus or control signal interface according to the specific industrial protocol requirements of your automation system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a low-impedance ground connection to the cabinet chassis to ensure safety and to meet strict electromagnetic compatibility (EMC) standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052844395,"sku":"EVS9322-ESV004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9322-esv004-zskxuepe1iz.png?v=1776236563"},{"product_id":"lenze-9300-series-evs9325-es-servo-inverter","title":"Lenze 9300-Series EVS9325-ES Servo Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEVS9325-ES\u003c\/strong\u003e is a reliable \u003cstrong\u003eservo inverter\u003c\/strong\u003e from the \u003cstrong\u003eLenze 9300-Series\u003c\/strong\u003e, engineered for precise motor control in industrial automation. Providing a rated power output of \u003cstrong\u003e5.5 kW\u003c\/strong\u003e, this controller is designed to manage motion tasks with high efficiency and precision. With an \u003cstrong\u003eIP20\u003c\/strong\u003e protection rating, it is optimized for cabinet-integrated installations. This unit is well-suited for production leaders looking for dependable motion control solutions within established industrial architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance Servo Control:\u003c\/strong\u003e Part of the established 9300-Series, known for advanced motion control algorithms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Power:\u003c\/strong\u003e 5.5 kW capacity for demanding production line applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP20 Protection:\u003c\/strong\u003e Suitable for mounting in protected control cabinet environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Engineering:\u003c\/strong\u003e Designed for high-accuracy speed, torque, and position regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Integration:\u003c\/strong\u003e Proven performance in diverse manufacturing environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e9300-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.70 x 38.10 x 25.10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044086\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure vertical mounting within the control cabinet to facilitate proper convective cooling through the integrated heat sink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Clearance:\u003c\/strong\u003e Maintain the manufacturer's recommended clearances above and below the drive to prevent overheating during high-duty cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Protect the drive from aggressive gases, high humidity, and conductive dust to ensure long-term stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize shielded cabling for motor and feedback connections to minimize electromagnetic interference (EMI) and ensure signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e A robust connection to the cabinet's protective earth (PE) is required to ensure both operator safety and electromagnetic compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052909931,"sku":"EVS9325-ES","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9325-es-5wyccorst0k.png?v=1776236663"},{"product_id":"lenze-9300-series-evs9328-ek-servo-cam-profiler","title":"Lenze 9300-Series EVS9328-EK Servo Cam Profiler","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEVS9328-EK\u003c\/strong\u003e is a robust, high-capacity \u003cstrong\u003eservo cam profiler\u003c\/strong\u003e from the \u003cstrong\u003eLenze 9300-Series\u003c\/strong\u003e. Engineered for heavy-duty industrial applications, this unit provides a substantial rated power of \u003cstrong\u003e22.0 kW\u003c\/strong\u003e, making it an essential component for high-torque and high-speed motion control systems. Despite its phase-out status (designated in 2017), it continues to be a trusted solution for operational infrastructures requiring precise synchronization and reliable performance in protected, cabinet-mounted environments (IP20).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Power Motion Control:\u003c\/strong\u003e Rated for 22.0 kW to handle demanding industrial loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eServo Cam Profiler:\u003c\/strong\u003e Facilitates advanced electronic synchronization and complex motion profiling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Reliability:\u003c\/strong\u003e Built to the high standards of the 9300-series, ensuring longevity and consistent performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet-Ready:\u003c\/strong\u003e Compact design optimized for efficient space usage within industrial enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e9300-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Cam Profiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e22.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.00 x 25.00 x 25.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e12.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Due to the 22 kW power capacity, ensure the unit is mounted vertically with generous clearance above and below to allow the cooling fans to operate efficiently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Because this drive generates significant heat, the control cabinet must feature forced-air ventilation or air conditioning to prevent thermal derating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded motor cables and ensure high-frequency grounding to the cabinet backplane to comply with EMC requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Before performing maintenance, confirm the drive's DC bus is fully discharged. Due to the high power of this unit, strictly follow your facility’s Lock-Out\/Tag-Out (LOTO) procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Considerations:\u003c\/strong\u003e Since this unit has been phased out, ensure you have access to appropriate diagnostic cables and legacy software (e.g., Global Drive Control) for configuration and troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052975467,"sku":"EVS9328-EK","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9328-ek-eez53xb2paa.png?v=1776236713"},{"product_id":"lenze-9300-series-evs9327-ek-servo-cam-profiler","title":"Lenze 9300-Series EVS9327-EK Servo Cam Profiler","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEVS9327-EK\u003c\/strong\u003e is a powerful \u003cstrong\u003eservo cam profiler\u003c\/strong\u003e from the \u003cstrong\u003eLenze 9300-Series\u003c\/strong\u003e, specifically engineered for high-demand industrial motion control applications. Boasting a rated power of \u003cstrong\u003e15.0 kW\u003c\/strong\u003e, this servo controller excels in managing complex, synchronized motion profiles required for high-speed production lines. It features an IP20 protection rating and is designed for cabinet-mounted installations, offering the precision and reliability expected of the 9300-series in a robust, industrial-grade package.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Power Motion Control:\u003c\/strong\u003e Rated at 15.0 kW for heavy-duty industrial tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eServo Cam Profiling:\u003c\/strong\u003e Advanced functionality for precise, electronically synchronized mechanical movements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP20 Protection:\u003c\/strong\u003e Robust design suitable for installation within protected control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Engineering:\u003c\/strong\u003e High-performance regulation for speed, torque, and position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven Reliability:\u003c\/strong\u003e A staple of the 9300-Series, trusted for demanding production environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e9300-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Cam Profiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e15.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.00 x 25.00 x 25.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e12.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Due to the higher power rating (15 kW), ensure the unit is mounted vertically with adequate clearance above and below for maximum airflow through the integrated cooling system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Given the power output, the control cabinet must have adequate ventilation or active cooling to maintain ambient temperatures within the manufacturer's specified limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded motor cabling with proper EMC cable glands to prevent electromagnetic interference. Ensure that power and signal cables are separated to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e A high-integrity, low-impedance connection to the system protective earth (PE) is essential, particularly for a drive of this power class, to ensure safety and EMI immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSetup:\u003c\/strong\u003e Configure motion profiles using the Lenze programming software to ensure the electronic camming matches the mechanical requirements of the application.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105053041003,"sku":"EVS9327-EK","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9327-ek-0tnfns2o3tv.png?v=1776236698"},{"product_id":"lenze-8200-series-e82ev751-2c902-vector-frequency-inverter","title":"Lenze 8200-Series E82EV751-2C902 Vector Frequency Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eE82EV751-2C902\u003c\/strong\u003e is a high-performance \u003cstrong\u003evector frequency inverter\u003c\/strong\u003e belonging to the \u003cstrong\u003eLenze 8200-series\u003c\/strong\u003e. It is engineered to provide precise motor speed and torque control in demanding industrial applications. This 3-phase unit is rated for \u003cstrong\u003e0.75 kW (1 HP)\u003c\/strong\u003e and offers a broad output frequency range of 0–650 Hz. Designed for seamless integration into automated systems, this inverter ensures reliable operational control in environments ranging from general mechanical engineering to complex process automation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVector Control Technology:\u003c\/strong\u003e Delivers superior speed regulation and torque control compared to standard V\/f drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Performance:\u003c\/strong\u003e Rated for 0.75 kW (1 HP) with an output frequency up to 650 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Robustness:\u003c\/strong\u003e Built for standard 230\/240 VAC 3-phase power supply architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace-Optimized:\u003c\/strong\u003e Compact dimensions (15.20 x 10.20 x 20.30 cm) facilitate easy mounting in control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e8200-series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Frequency Drive (VFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e0.75 kW (1 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e230\/240 VAC (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0–650 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.20 x 10.20 x 20.30 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the inverter vertically within a control cabinet to facilitate optimal heat dissipation through the integrated cooling channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Adhere to manufacturer-recommended spacing above and below the unit to ensure adequate airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded motor cables and ensure they are separated from control signal cables to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain a solid, low-impedance connection to the cabinet's protective earth (PE) bus to ensure safety and EMC compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Avoid installation sites prone to excessive moisture, conductive dust, or aggressive atmospheric gases.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105053106539,"sku":"E82EV751_2C902","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev751-2c902-pstat4jhg13.png?v=1776235901"},{"product_id":"lenze-ecs-ecsem016c4b-axis-module-servo-drive","title":"Lenze ECS ECSEM016C4B Axis Module Servo Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eECSEM016C4B\u003c\/strong\u003e is a high-performance \u003cstrong\u003eaxis module\u003c\/strong\u003e from the \u003cstrong\u003eLenze ECS Servo System\u003c\/strong\u003e family. This unit is designed to function as part of a modular multi-axis servo system, converting DC bus voltage (565\/675 VDC) into precise AC output (0-400\/480 VAC) to drive motors with high accuracy. While this module is now classified as \u003cstrong\u003eObsolete\u003c\/strong\u003e, it remains a critical component for the maintenance and repair of established industrial motion control architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Servo System:\u003c\/strong\u003e Specifically engineered as an axis module for scalable multi-axis applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Power Conversion:\u003c\/strong\u003e Accepts 565\/675 VDC input and provides 0–400\/480 VAC output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Performance:\u003c\/strong\u003e Rated for 16 A overload capacity, suitable for high-acceleration and high-torque production cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Frequency Range:\u003c\/strong\u003e Output frequency capability from 0 to 600 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Industrial Design:\u003c\/strong\u003e Built to withstand the rigors of automated production environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eECS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC Drive \/ Axis Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e565 \/ 675 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e0–400 \/ 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (Out)\u003c\/td\u003e\n\u003ctd\u003e8 \/ 6.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Capacity\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0–600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegration:\u003c\/strong\u003e This module must be integrated into a larger ECS multi-axis system configuration. Ensure the DC bus connection and EtherCAT\/communication cables are properly secured.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Because this is a high-power axis module, ensure sufficient airflow within the control cabinet. Keep the cooling fins free of dust and debris to prevent thermal shutdowns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Given the high DC bus voltages (up to 675 VDC), ensure that the system is fully discharged before performing any maintenance or wiring tasks. Always verify the DC bus status using a certified multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e To ensure EMI compatibility, maintain a clean, low-impedance ground connection to the cabinet backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Support:\u003c\/strong\u003e As this is an obsolete component, ensure that firmware compatibility with your existing supply module and controller is verified before replacement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105053172075,"sku":"ECSEM016C4B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ecsem016c4b-auawu5f5gfr.png?v=1776236263"},{"product_id":"lenze-9400-series-e94ashe0034-servo-drive","title":"Lenze 9400-Series E94ASHE0034 Servo Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eE94ASHE0034\u003c\/strong\u003e is a high-performance \u003cstrong\u003esingle servo drive\u003c\/strong\u003e from the \u003cstrong\u003eLenze 9400-series\u003c\/strong\u003e, specifically engineered for complex motion control tasks. Rated for \u003cstrong\u003e0.75 kW\u003c\/strong\u003e, this unit is optimized for three-phase industrial networks. It offers high flexibility in input voltage, supporting stable operation at a nominal voltage of \u003cstrong\u003e400 V\u003c\/strong\u003e. As part of the active 9400-series, it provides the advanced diagnostic and synchronization features necessary for modern, high-precision automated production lines.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance Motion Control:\u003c\/strong\u003e Part of the advanced 9400-series architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Power Input:\u003c\/strong\u003e Designed for 400 V nominal voltage with wide input ranges for robust industrial compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Engineering:\u003c\/strong\u003e Ideal for applications requiring high-speed synchronization and positioning accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Status:\u003c\/strong\u003e Currently in the active product lifecycle phase, ensuring long-term support and availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Engineered for efficient cabinet integration (35.00 x 25.00 x 7.80 cm).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e9400-series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Drive (Single Drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.00 x 25.00 x 7.80 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install vertically within a control cabinet, ensuring adequate clearance above and below the drive to facilitate the integrated cooling system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Protect the drive from humidity, conductive dust, and extreme temperature variations. Ensure the ambient air is within specified limits for electronic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Employ shielded cables for motor connections to ensure compliance with EMC standards and prevent noise interference with low-voltage control signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Connect the PE (Protective Earth) terminal to a high-integrity ground plane to ensure both operator safety and system performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize the Lenze software suite to configure motor parameters and motion profiles for optimal system performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105053237611,"sku":"E94ASHE0034","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e94ashe0034-vgqmlat0xlh.png?v=1776236124"}],"url":"https:\/\/www.plcprotech.com\/pl\/collections\/lenze.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}