{"title":"Power \u0026 Electrical Components","description":"\u003cp\u003ePower and electrical components support reliable energy distribution and protection within control panels and industrial equipment. Architecturally, this includes power supplies, transformers, contactors, relays, breakers, terminal systems, fuses, surge protection, and related cabinet hardware that interfaces between incoming power and automation loads. Technical characteristics focus on voltage and current ratings, efficiency, isolation, inrush handling, protective trip behavior, heat dissipation, and compliance with industrial installation requirements. Functional capability includes converting and stabilizing power, switching loads, protecting circuits, providing control voltages, and supporting safe maintenance through isolation and fault protection. For motion systems that depend on stable power and protection, see \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/drives-motion-control\"\u003eDrives \u0026amp; Motion Control\u003c\/a\u003e. For control and process platforms using these panel components, visit \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/dcs-control-systems\"\u003eDCS \u0026amp; Control Systems\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-3500-15-133292-01-low-voltage-dc-power-supply-module","title":"Moduł zasilania niskonapięciowego prądu stałego Bently Nevada 133292-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e133292-01\u003c\/strong\u003e to półwysoki moduł sprzętowy zaprojektowany do dostarczania stabilnego i regulowanego zasilania w \u003cstrong\u003eSystemie Ochrony Maszyn Serii 3500\u003c\/strong\u003e. Działa jako tradycyjna jednostka regulacji niskonapięciowego zasilania, przekształcając niskonapięciowe źródła prądu stałego na określone profile napięć wymagane do pracy sąsiednich modułów monitorowania stanu i przetwarzania tablic. Umieszczony w dedykowanych gniazdach po lewej stronie standardowej ramy rack, ten moduł może działać jako samodzielne źródło zasilania lub w konfiguracji równoległej z drugim identycznym modułem, zapewniając nieprzerwaną redundancję systemu. Karta przyjmuje specjalistyczne niskonapięciowe wejścia DC przez odpowiadający tylny moduł zasilania (\u003cstrong\u003ePIM\u003c\/strong\u003e), co czyni ją niezbędnym zapasowym elementem w zautomatyzowanych zakładach produkcyjnych, obiektach petrochemicznych i instalacjach ciężkich turbin wymagających infrastruktury monitoringu o wysokiej dostępności.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePółwysoki fizyczny rozmiar, aby pasować do wyznaczonych lewych gniazd zasilania w ramie chassis.\u003c\/li\u003e\n\u003cli\u003eIntegruje tryb redundancji zasilania z automatyczną logiką przełączania główny\/zapasowy po zainstalowaniu modułu zapasowego.\u003c\/li\u003e\n\u003cli\u003eArchitektura instalacji umożliwiająca wymianę na gorąco, pozwalająca na bezpośrednią wymianę uszkodzonego bloku bez zakłócania aktywnych pętli ochrony maszyn.\u003c\/li\u003e\n\u003cli\u003eWbudowana diagnostyka z przodu urządzenia z dedykowaną diodą LED wskazującą prawidłową pracę modułu.\u003c\/li\u003e\n\u003cli\u003eKompleksowe środki bezpieczeństwa przed podnapięciem zaprojektowane w celu ochrony wielowarstwowych płytek obwodów wewnętrznych przed uszkodzeniami elektrycznymi.\u003c\/li\u003e\n\u003cli\u003eWysoka kompatybilność z tradycyjnymi niskonapięciowymi rozdzielnicami DC dla efektywnej migracji sprzętu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZasilanie szaf ochrony maszyn na odległych rurociągach transportu ropy i gazu zasilanych niskonapięciowymi bateriami DC.\u003c\/li\u003e\n\u003cli\u003eZarządzanie dystrybucją energii dla lokalnych tablic drgań wirujących urządzeń w jednostkach przetwórstwa petrochemicznego.\u003c\/li\u003e\n\u003cli\u003eZasilanie krytycznych sieci śledzenia turbin i generatorów wykorzystujących samodzielne instalacje solarne lub banki baterii.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/15-AA-BB-CC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKompletna struktura zamówienia zespołu zasilacza.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja starszego niskonapięciowego DC (20 do 30 V DC) dla górnego gniazda.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja starszego niskonapięciowego DC (20 do 30 V DC) dla dolnego gniazda.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: Brak.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: CSA\/NRTL\/C (Klasa 1, Podział 2).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: ATEX \/ IECEX \/ CSA (Klasa 1, Strefa 2).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e133292-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzęści zamienne:\u003c\/strong\u003e Starszy moduł zasilania niskonapięciowego DC.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e133300-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzęści zamienne:\u003c\/strong\u003e Starszy moduł zasilania niskonapięciowego DC.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01720045\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzęści zamienne:\u003c\/strong\u003e Wymienny bezpiecznik (moduł zasilania niskonapięciowego DC i starszy moduł zasilania niskonapięciowego DC).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKategoria parametru\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części zamiennej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e133292-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZakres napięcia wejściowego 20 do 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePełne obciążenie prądowe szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksymalny prąd 11,0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBłąd niedonapięcia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZasilanie chronione, brak uszkodzeń modułu lub PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOchrona przed przepięciem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWyzwala status otwarty na wyznaczonym głównym bezpieczniku PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNie jest wymagane minimalne obciążenie szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSzerokość modułu zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50,8 mm (2,0 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWysokość modułu zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm (4,75 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGłębokość modułu zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e251,5 mm (9,9 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cp\u003eUkład interfejsu zarządza statusami zasilania i śledzeniem połączeń w systemie obudowy:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIdentyfikator komponentu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis funkcjonalny \/ Przypisanie\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED ZASILANIE OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLampka statusu na przednim panelu; świeci się na stałe na zielono, gdy wewnętrzne szyny generują odpowiednie napięcia.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGórne gniazdo karty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWyznaczone gniazdo po lewej stronie ramy pełniące funkcję zapasowej\/drugorzędnej zatoki.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDolne gniazdo karty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWyznaczone gniazdo po lewej stronie ramy pełniące funkcję głównego źródła zasilania systemu.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMontaż tylnej płytki PIM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecjalne miejsce odbiorcze bezpośrednio za kartą do przechwytywania niskonapięciowych linii prądu stałego.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział gniazda:\u003c\/strong\u003e Montuj jednostkę wyłącznie w wyznaczonych oknach gniazd o połowie wysokości po lewej stronie głównej ramy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePriorytet nadmiarowości:\u003c\/strong\u003e Umieść moduł sprzętowy w dolnej zatoce o połowie wysokości, aby przypisać go jako główne źródło zasilania, lub wykorzystaj górną pozycję zatoki jako zapasową.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDobór modułu PIM:\u003c\/strong\u003e Zawsze łącz moduł zasilający \u003cstrong\u003e133292-01\u003c\/strong\u003e z odpowiednim legacy niskonapięciowym modułem PIM tylnej płyty (numer części 133300-01), aby uniknąć niezgodności elektrycznych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWymiana na gorąco:\u003c\/strong\u003e Upewnij się, że w przeciwnym gnieździe zasilania pozostaje aktywna karta zasilająca przed usunięciem lub wymianą tego elementu na działającym urządzeniu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonserwacja bezpieczników:\u003c\/strong\u003e W przypadku wystąpienia przepięcia sprawdź i wymień dedykowany bezpiecznik ochronny (numer części 01720045) w powiązanym module interfejsu tylnej płyty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e Dyrektywa Wspólnoty Europejskiej 2014\/30\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy EMC:\u003c\/strong\u003e EN 61000-6-2 (odporność przemysłowa), EN 61000-6-4 (emisje przemysłowe).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Dyrektywa niskonapięciowa 2014\/35\/UE, norma EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa RoHS:\u003c\/strong\u003e Zgodność europejska 2011\/65\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty Morskie:\u003c\/strong\u003e Zasady klasyfikacji DNV GL, ABS Steel Vessels Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty Ameryki Północnej:\u003c\/strong\u003e cNRTLus Klasa I, Podział 2, Grupy A, B, C i D (T4 @ Ta = -20°C do +65°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty ATEX\/IECEx:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest funkcjonalna różnica między modułem 133292-01 a zaktualizowanymi, wysokosprawnymi modułami zasilania DC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł 133292-01 to moduł niskonapięciowy DC typu legacy, zaprojektowany specjalnie dla starszych typów rozdziałów zasilania 3500 i jest wyraźnie niekompatybilny ze standardowymi, nowoczesnymi modułami wejścia zasilania niskonapięciowego DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł sprzętowy wymaga minimalnego obciążenia elektrycznego, aby utrzymać bezpieczne poziomy napięcia wyjściowego?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, topologia przetwarzania karty oznacza, że nie jest wymagane minimalne obciążenie stojaka dla prawidłowej regulacji obwodu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy tymczasowe obniżenie napięcia na wejściu 24V zniszczy wewnętrzne komponenty?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, zmiana napięcia wejściowego poniżej normy nie powoduje uszkodzeń operacyjnych ani trwałego pogorszenia działania wewnętrznych komponentów sprzętowych lub powiązanego modułu PIM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy mogę jednocześnie używać zasilacza AC i modułu niskonapięciowego DC 133292-01 w tym samym stojaku?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, obudowa monitora obsługuje umieszczanie dowolnej kombinacji modułów zasilania prądem przemiennym i stałym w dwóch gniazdach, tworząc wysoce wszechstronną, redundantną konfigurację.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517651819,"sku":"133292-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-133292-01-low-voltage-dc-power-supply-module-cxxxu02b1cn_a888c3aa-81d1-43f2-ba03-bd0e04a3fa6b.jpg?v=1765440107"},{"product_id":"bently-nevada-3500-15-127610-01-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15 127610-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł zasilania \u003cstrong\u003eBently Nevada 3500\/15\u003c\/strong\u003e to moduł o wysokiej dostępności, zaprojektowany do niezawodnego i regulowanego zasilania systemu monitorującego 3500. Instalowany w najbardziej lewych slotach szafy 3500, \u003cstrong\u003e127610-01\u003c\/strong\u003e akceptuje szeroki zakres napięć wejściowych AC i przetwarza je na niezbędne napięcia DC wymagane przez inne moduły w tej samej szafie. \u003cstrong\u003e3500\/15\u003c\/strong\u003e obsługuje konfiguracje redundantne, pozwalając na jednoczesną instalację dwóch modułów w jednej szafie, aby zapewnić nieprzerwaną pracę krytycznych systemów monitorowania drgań i ochrony maszyn w środowiskach przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObsługuje konfiguracje redundantne zasilania, aby zapobiec przestojom systemu.\u003c\/li\u003e\n\u003cli\u003eKompatybilny ze standardowymi szafami monitorującymi serii 3500.\u003c\/li\u003e\n\u003cli\u003eUtrzymuje stałe dostarczanie mocy przy zmiennych częstotliwościach wejściowych.\u003c\/li\u003e\n\u003cli\u003eZaprojketowany do pracy w trudnych warunkach przemysłowych z rozszerzonym zakresem temperatur pracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystemy ochrony maszyn (TSI)\u003c\/li\u003e\n\u003cli\u003eCiągły monitoring drgań\u003c\/li\u003e\n\u003cli\u003eZasoby przemysłu naftowego i gazowego, energetycznego oraz petrochemicznego\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 35.443%;\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 64.135%;\"\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eNumer części \/ model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e3500\/15 (127610-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eModuł zasilania AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eLegacy wysokie napięcie AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eNominalne napięcie wejściowe AC wysokiego napięcia Legacy 220 Vac (175 do 264 Vac rms, 247 do 373 Vac pk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eLegacy niskie napięcie AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eNominalne napięcie wejściowe AC niskiego napięcia Legacy 110 Vac (85 do 132 Vac rms, 120 do 188 Vac pk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eUniwersalne napięcie wejściowe AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003eNominalne napięcie wejściowe AC 110 do 220 Vac (85 do 264 Vac rms, 120 do 373 Vac pk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eZakres częstotliwości wejściowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e47 do 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e-30 do +65 stopni Celsjusza (-22 do +150 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e-40 do +85 stopni Celsjusza (-40 do +185 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.443%;\"\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.135%;\"\u003e1,39 kg (3,06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmiejscowienie w slocie:\u003c\/strong\u003e Instaluj moduł zasilania tylko w dedykowanych slotach zasilania po lewej stronie szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKompatybilność modułów:\u003c\/strong\u003e Upewnij się, że moduł zasilania AC i tylny moduł wejścia zasilania (PIM) mają zgodny typ konfiguracji (Universal vs. Legacy) przed podłączeniem zasilania. Moduły Universal nie są kompatybilne z jednostkami Legacy o wysokim lub niskim napięciu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja redundancji:\u003c\/strong\u003e Przy użyciu dwóch modułów zasilania do redundancji, podłącz każde zasilanie do oddzielnego, niezależnego źródła zasilania, aby zmaksymalizować niezawodność systemu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChłodzenie i wentylacja:\u003c\/strong\u003e Zachowaj odpowiedni odstęp wokół obudowy szafy, aby spełnić określone limity temperatury otoczenia podczas pracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518962539,"sku":"3500\/15 127610-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-127610-01-power-supply-module-horgjmyfeju_4270d19c-b1f7-473d-96b3-908e4ec414e9.jpg?v=1765440124"},{"product_id":"bently-nevada-129486-01-3500-15-legacy-high-voltage-dc-power-supply-module","title":"Moduł zasilania wysokiego napięcia prądu stałego Bently Nevada 129486-01 3500\/15 Legacy","description":"\u003cp\u003eModuł \u003cstrong\u003e129486-01\u003c\/strong\u003e to \u003cstrong\u003emoduł zasilania stałym napięciem wysokiego napięcia 3500\/15 Legacy\u003c\/strong\u003e zaprojektowany do dostarczania regulowanego zasilania do pełnej szafy systemu ochrony maszyn serii 3500. Ten moduł o połowie wysokości akceptuje wejście wysokiego napięcia stałego i przekształca je na precyzyjnie regulowane poziomy odpowiednie do pracy innych zintegrowanych modułów monitorujących 3500. Szafa systemu 3500 mieści do dwóch zasilaczy jednocześnie po lewej stronie, tworząc w pełni redundantną architekturę zasilania, gdzie moduł w dolnym slocie pełni funkcję zasilacza podstawowego, a moduł w górnym slocie działa jako zasilacz zapasowy. Wkładanie lub wyjmowanie dowolnego modułu zasilania może być wykonywane podczas pracy na żywo bez zakłócania funkcji systemu szafy, pod warunkiem, że drugi źródło zasilania pozostaje aktywne.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWsparcie pracy redundantnej\u003c\/strong\u003e: Pozwala na jednoczesne zainstalowanie dwóch jednostek w jednej ramie szafy, tworząc zautomatyzowany układ bezpieczeństwa zasilania podstawowego i zapasowego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMożliwość wymiany na gorąco\u003c\/strong\u003e: Umożliwia bezpieczne usuwanie lub wkładanie pojedynczych modułów bez przerywania działania ochrony maszyn.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZintegrowane zabezpieczenia bezpieczeństwa\u003c\/strong\u003e: Wyposażony w wbudowaną ochronę przed przepięciem, która inicjuje stan przerwania bezpiecznika na module zasilania, zabezpieczając elektronikę wewnętrzną.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWskaźnik diagnostyczny stanu\u003c\/strong\u003e: Panel przedni zawiera dedykowaną zieloną diodę LED \"SUPPLY OK\", zapewniającą natychmiastowe wizualne potwierdzenie prawidłowego działania modułu zasilania.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstalacje zapasowej infrastruktury zasilania wysokim napięciem stałym dla ochrony krytycznych maszyn obrotowych.\u003c\/li\u003e\n\u003cli\u003eZapasowa wymiana modułu zasilania w szafach monitorujących turbiny parowe i gazowe na skalę użyteczności publicznej.\u003c\/li\u003e\n\u003cli\u003eCiągłe dostarczanie mocy dla dużych przemysłowych sprężarek powietrza i gazu odśrodkowego wykorzystujących szafy serii 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOznaczenie slotu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTyp zasilacza\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGórny slot \/ Dolny slot\u003c\/td\u003e\n\u003ctd\u003eLegacy wysokie napięcie stałe (88 do 140 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (firma Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e129486-01 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł zasilania stałym napięciem wysokiego napięcia 3500\/15 Legacy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne napięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 do 140 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny prąd pobierany przez pełną szafę\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,5 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOchrona przed zbyt niskim napięciem poza zakresem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNie uszkadza zasilacza ani PIM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOchrona przed nadmiernym napięciem poza zakresem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowoduje przepalenie bezpiecznika w odpowiadającym PIM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie systemu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrak wymaganego minimalnego obciążenia szafy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wilgotności względnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary fizyczne modułu (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga fizyczna modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja gniazd\u003c\/strong\u003e: Instaluj zasilacz wyłącznie w wyznaczonych gniazdach o połowie wysokości, znajdujących się po lewej stronie szafy systemu 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział redundancji\u003c\/strong\u003e: Przy wdrażaniu pary redundantnej umieść zasilacz podstawowy w dolnym gnieździe, a jednostkę zapasową bezpośrednio w górnym gnieździe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOchrona izolacji wejściowej\u003c\/strong\u003e: Sprawdź, czy sparowany moduł zasilania DC wysokiego napięcia (PIM) jest zainstalowany bezpośrednio za wyznaczonym gniazdem zasilania przed podłączeniem linii zasilających.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZarządzanie termiczne\u003c\/strong\u003e: Zapewnij, aby temperatura otoczenia szafy mieściła się w określonym zakresie roboczym od -30°C do +65°C, aby zachować trwałość wewnętrznych komponentów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa EMC\u003c\/strong\u003e: Spełnia wymagania Dyrektywy Wspólnoty Europejskiej 2014\/30\/EU na podstawie norm EN 61000-6-2 (odporność przemysłowa) oraz EN 61000-6-4 (emisje przemysłowe).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne\u003c\/strong\u003e: Spełnia wymagania Dyrektywy niskonapięciowej 2014\/35\/EU oraz parametry projektowe EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo środowiskowe\u003c\/strong\u003e: Zgodne z ograniczeniami europejskiej dyrektywy ROHS 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKlasyfikacje morskie\u003c\/strong\u003e: Formalnie zarejestrowane zgodnie z zasadami klasyfikacji DNV GL dla statków i jednostek offshore, wraz z zasadami ABS dla Warunków Klasyfikacji Część 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy dotyczące stref zagrożonych\u003c\/strong\u003e: Certyfikowane dla Klasy I, Strefy 2 (AEx\/Ex nA nC ic IIC T4 Gc \/ AEx\/Ex ec nC ic IIC T4 Gc) oraz Klasy I, Dywizji 2, Grup A, B, C i D w środowisku temperaturowym od -20°C do +65°C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519126379,"sku":"129486-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-129486-01-high-dc-power-supply-module-wvwdqpan0gu_14fe870c-2312-462b-a277-3e9beb1e5f01.jpg?v=1765440129"},{"product_id":"bently-nevada-3500-32-4-channel-relay-module","title":"Moduł przekaźnikowy Bently Nevada 3500\/32 4-kanałowy","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModel \u003cstrong\u003e3500\/32\u003c\/strong\u003e to komponent pełnowymiarowy zaprojektowany dla systemu ochrony maszyn \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e, oferujący cztery w pełni programowalne wyjścia przekaźnikowe. Moduł ten można umieścić w dowolnym slocie po prawej stronie modułu interfejsu szafy, aby sterować krytyczną logiką alarmową i wyłączania maszyn. Każdy przekaźnik wykorzystuje wysoce konfigurowalną logikę sterowania alarmem, którą można programować za pomocą kombinacji AND i OR alertów i zagrożeń z dowolnego kanału monitorującego w szafie. Ta zdecentralizowana konfiguracja logiki działa za pomocą oprogramowania 3500 Rack Configuration Software, realizując działania ochronne natychmiastowo, niezależnie od kontroli oprogramowania nadrzędnego.\u003c\/p\u003e\n\u003cp\u003eSprzęt wykorzystuje wysoce odporną konfigurację przekaźników składającą się z dwóch przekaźników jednobiegunowych, dwupozycyjnych (SPDT) ułożonych w konfigurację dwubiegunową, dwupozycyjną (DPDT) dla każdego z czterech kanałów. Każdy kanał posiada przełącznik umożliwiający wybór trybu Normalnie Wyłączony lub Normalnie Załączony, co pozwala na elastyczne dostosowanie do bezpiecznych układów przemysłowych. Wbudowane diody LED umożliwiają operatorom terenowym dynamiczne, szybkie monitorowanie stanu magistrali komunikacyjnych i warunków alarmowych poszczególnych przekaźników.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCztery niezależne wyjścia przekaźnikowe oferujące w pełni konfigurowalne, specyficzne dla kanału ścieżki logiki głosowania.\u003c\/li\u003e\n\u003cli\u003eProgramowanie logiki sterowania alarmem wspierające rozbudowane kombinacje parametrów AND\/OR na wejściach całej szafy.\u003c\/li\u003e\n\u003cli\u003ePodwójne przekaźniki SPDT połączone w solidną konfigurację DPDT dla każdego niezależnego kanału.\u003c\/li\u003e\n\u003cli\u003ePrzekaźniki uszczelnione epoksydowo zintegrowane ze standardowymi tłumikami łuku 250 Vrms dla trwałego bezpieczeństwa styków.\u003c\/li\u003e\n\u003cli\u003eWbudowany przełącznik umożliwiający bezpośrednie przełączanie między stanami Normalnie Załączony i Normalnie Wyłączony.\u003c\/li\u003e\n\u003cli\u003ePrzejrzysta diagnostyka LED na przednim panelu wskazująca stan modułu OK, komunikację (TX\/RX) oraz status alarmu poszczególnych kanałów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatyczne rejestrowanie awaryjnych wyłączeń i pętle zatrzymania maszyn w krytycznych turbinach przemysłowych.\u003c\/li\u003e\n\u003cli\u003eSystemy bezpieczeństwa zakładu z blokadami oraz sieci sterujące wizualnymi\/dźwiękowymi sygnalizatorami alarmowymi.\u003c\/li\u003e\n\u003cli\u003eRozproszone konfiguracje logiki głosowania dla matryc ochrony bilansu instalacji w elektrowniach i rafineriach ropy naftowej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReferencja zamówienia produktu\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGłówne oznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32 (Moduł przekaźnikowy 4-kanałowy) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpcja modułu wyjściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01 (Moduł I\/O przekaźnikowy 4-kanałowy) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00 (Brak) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-01 (CSA \/ NRTL \/ C) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł przekaźnikowy 4-kanałowy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo 6 watów \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKonfiguracja typu przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDwa przekaźniki SPDT połączone w konfiguracji DPDT na kanał \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUszczelnienie środowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUszczelnienie epoksydowe \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOcena tłumika łuku\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms (standardowo zainstalowany) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrwałość styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 000 cykli przy 5 A, 24 Vdc lub 120 Vac \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaksymalne napięcie przełączane\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003edc: 30 Vdc \/ ac: 250 Vac \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny prąd przełączany\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalny prąd przełączany\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA przy 5 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMoc przełączana\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003edc: 120 W \/ ac: 600 VA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu głównego (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 242 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,7 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 99,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,4 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatur pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatur przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOgraniczenia wilgotności\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania przestrzeni w szafie (główne)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe przednie gniazdo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania przestrzeni w szafie (I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe tylne gniazdo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePołączenie zaciskowe\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunkt podłączenia styku normalnie zamkniętego na kanał przekaźnika \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eARM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunkt podłączenia styku ramienia\/wspólnego na kanał przekaźnika \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunkt podłączenia styku normalnie otwartego na kanał przekaźnika \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTRYB PRZEKAŹNIKA (NDE\/NE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzełączniki suwakowe sprzętowe kontrolujące stany załączenia poszczególnych kanałów \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmieszczenie modułu:\u003c\/strong\u003e Wsuń główną kartę bezpośrednio do dowolnego dostępnego pełnowymiarowego przedniego gniazda po prawej stronie modułu interfejsu szafy. Włóż odpowiadający moduł I\/O do pasującego tylnego gniazda obudowy. Zamocuj wszystkie śruby płyty czołowej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWybór trybu przekaźnika:\u003c\/strong\u003e Ustaw dedykowane przełączniki sprzętowe na panelu I\/O przed włączeniem modułu, aby ustawić tryb Normalnie Rozłączony (NDE) lub Normalnie Załączony (NE) zgodnie z projektem pętli.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracje okablowania:\u003c\/strong\u003e Podłącz wszystkie obwody urządzeń zewnętrznych do tylnego bloku zacisków śrubowych. Zapewnij prawidłowe podłączenie segmentów NC, ARM i NO, aby zapobiec błędom sygnalizacji mechanicznej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUziemienie elektrostatyczne:\u003c\/strong\u003e Używaj jednorazowej opaski uziemiającej na nadgarstek podczas rozpakowywania lub modyfikacji parametrów wewnętrznego obwodu, aby chronić elementy płytki przed wyładowaniami elektrostatycznymi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy oznakowania CE:\u003c\/strong\u003e Zgodność ze standardami dyrektywy EMC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmisje promieniowane i przewodzone:\u003c\/strong\u003e EN 55011, Klasa A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard odporności i podatności:\u003c\/strong\u003e IEC 61000-6-2, w tym ESD (61000-4-2), promieniowanie (ENV 50140), przewodzenie (ENV 50141), EFT (EN 61000-4-4), przepięcia (EN 61000-4-5) oraz pole magnetyczne (61000-4-8).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożonych:\u003c\/strong\u003e Certyfikat CSA\/NRTL\/C dla Klasy I, Podział 2, Grupy A, B, C, D (T4 @Ta = -20°C do +65°C; Numer certyfikatu: CSA 150268-1002151).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666544587115,"sku":"3500\/32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-32-4-channel-relay-module-bkzt4nr51v5_04f81160-46a1-4bce-8a94-c976310465bd.jpg?v=1765440504"},{"product_id":"bently-nevada-3500-15-114m5329-01-high-voltage-dc-power-supply","title":"Zasilacz wysokiego napięcia stałego Bently Nevada 3500\/15 114M5329-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 114M5329-01\u003c\/strong\u003e to moduł zasilania prądem stałym o wysokim napięciu w formacie półwysokości, zaprojektowany do integracji z systemem ochrony maszyn serii 3500. Ten moduł zasilania dostarcza regulowane napięcie stałe do wspólnych szyn zasilających, zapewniając stabilne napięcia robocze na sąsiednich kartach monitorujących, diagnostycznych i komunikacyjnych zamontowanych w ramie szafy. Działa w połączeniu z dedykowanym modułem wejściowym zasilania prądem stałym o wysokim napięciu (PIM) i umożliwia dowolne łączenie z alternatywnym źródłem zasilania prądem przemiennym, co pozwala na uzyskanie spersonalizowanych podwójnych ścieżek zasilania. W konfiguracji systemu z podwójnym zasilaniem \u003cstrong\u003e114M5329-01\u003c\/strong\u003e umożliwia dynamiczne wyrównywanie sprzętowe, wspierając ciągłą ochronę maszyn w dużych zakładach przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObudowa półwysokości zoptymalizowana do montażu w lewym slocie zasilania\u003c\/li\u003e\n\u003cli\u003ePrawdziwa zdolność podwójnego zasilania online zapewniająca niezawodne automatyczne przełączanie awaryjne\u003c\/li\u003e\n\u003cli\u003eBezpośrednie fizyczne oddzielenie od krytycznych ścieżek bezpieczeństwa maszyn, zapobiegające przerwom technicznym\u003c\/li\u003e\n\u003cli\u003eW pełni wymienny na gorąco montaż umożliwiający prace konserwacyjne bez wyłączania systemów\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSzafy ochrony maszyn wymagające stabilnego zasilania z baterii stacji prądu stałego\u003c\/li\u003e\n\u003cli\u003ePlatformy monitorowania prędkości ciężkich sprężarek przemysłowych, turbin i pomp pomocniczych\u003c\/li\u003e\n\u003cli\u003eKrytyczna infrastruktura maszynowa w rafineriach ropy, zakładach petrochemicznych i elektrowniach\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114M5329-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZasilacz prądu stałego o wysokim napięciu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNapięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 do 140 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary (Wysokość x Szerokość x Głębokość)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział slotów\u003c\/strong\u003e: Wsuń moduł półwysokości wyłącznie do wyznaczonych slotów zasilania po lewej stronie obudowy szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja redundancji\u003c\/strong\u003e: Zainstaluj główny moduł zasilania w dolnym slocie, a zapasowy moduł zasilania w górnym slocie, aby utrzymać automatyczny układ awaryjny.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKompatybilność sprzętowa\u003c\/strong\u003e: Upewnij się, że zasilacz prądu stałego o wysokim napięciu jest sparowany wyłącznie z nowoczesnym modułem wejściowym zasilania prądem stałym o wysokim napięciu (PIM); jest całkowicie niekompatybilny ze starszym sprzętem PIM serii 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperacje wymiany na gorąco\u003c\/strong\u003e: Przed usunięciem lub wymianą modułu upewnij się, że co najmniej jedno zapasowe źródło zasilania pozostaje całkowicie aktywne i operacyjne, aby uniknąć przerwy w zasilaniu obudowy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666571981163,"sku":"3500\/15 114M5329-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-114m5329-01-high-voltage-dc-power-supply-jzh5fdotlq5_dbdf0a66-6f36-40c7-91ed-6ceecfd8e2ba.jpg?v=1765440857"},{"product_id":"bently-nevada-3500-15-04-04-00-114m5330-01-power-supply","title":"Zasilacz Bently Nevada 3500\/15-04-04-00 114M5330-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/15-04-04-00\u003c\/strong\u003e o numerze części \u003cstrong\u003e114M5330-01\u003c\/strong\u003e to moduł zasilania o połowie wysokości, zaprojektowany do dostarczania regulowanego napięcia stałego (DC) przez tylną płytę szyny systemu ochrony maszyn serii 3500. Ten moduł \u003cstrong\u003e3500\/15-04-04-00 114M5330-01\u003c\/strong\u003e działa w zakresie napięcia wejściowego od 20 do 30 V DC, przekształcając surowe źródło energii w wysoce stabilne zasilanie wymagane przez sąsiednie monitory, karty komunikacyjne i procesory przekaźnikowe. Zaprojektowany do montażu w dedykowanych gniazdach po lewej stronie głównej obudowy, system ten obsługuje zarówno konfiguracje samodzielne, jak i podwójnie redundantne. W konfiguracji podwójnej dolne gniazdo sprzętowe działa jako zasilanie podstawowe, podczas gdy górny moduł pozostaje w trybie hot-standby, wykonując natychmiastowe przełączenie w przypadku awarii obwodu nadrzędnego lub wyłączenia głównego modułu.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObsługa układu podwójnej redundancji z płynnym przejściem online z modułów podstawowych na zapasowe.\u003c\/li\u003e\n\u003cli\u003eArchitektura instalacji hot-swappable umożliwia wyjmowanie pojedynczych kart bez destabilizacji działania systemu.\u003c\/li\u003e\n\u003cli\u003eRegulowany obwód wyjściowy chroni płyty przetwarzające przed nagłymi skokami napięcia.\u003c\/li\u003e\n\u003cli\u003eWysoka zdolność prądowa pozwala zasilać w pełni wyposażoną szafę instrumentacyjną serii 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDystrybucja zasilania systemu do śledzenia zasobów maszyn i systemów drgań obudowy.\u003c\/li\u003e\n\u003cli\u003eKonfiguracje monitorowania maszyn zgodne z API 670.\u003c\/li\u003e\n\u003cli\u003eCiągłe zasilanie instrumentów dla turbin parowych, turbin gazowych i dużych sprężarek przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod sufiksu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeria produktu: Moduł zasilania 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTyp zasilacza (Górne gniazdo): Legacy niskonapięciowe DC (20 do 30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTyp zasilacza (Dolne gniazdo): Legacy niskonapięciowe DC (20 do 30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZatwierdzenie agencji: Brak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15-04-04-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114M5330-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy niskonapięciowy moduł zasilania DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 do 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrąd pełnej szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,0 A (maksymalnie)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 in x 2,0 in x 9,9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział gniazd:\u003c\/strong\u003e Montuj ten moduł o połowie wysokości wyłącznie w przydzielonych gniazdach po lewej stronie obudowy serii 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja redundantna:\u003c\/strong\u003e Umieść podstawowy zasilacz w dolnym gnieździe, a zapasowy w górnym, aby skonfigurować ciągłą redundancję zasilania zasobów.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyrównanie mechaniczne:\u003c\/strong\u003e Wsuń moduł prosto wzdłuż prowadnic obudowy, aż tylne złącze wielopinowe pewnie połączy się z siecią dystrybucji na płycie tylnej. Dokładnie dokręć śruby mocujące na przednim panelu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDobór PIM:\u003c\/strong\u003e Łącz ten niskonapięciowy komponent wyłącznie z odpowiadającym Legacy niskonapięciowym modułem wejściowym zasilania DC (PIM). Nie łącz ani nie mieszaj komponentów legacy z nowszymi uniwersalnymi modułami AC lub alternatywnymi modułami DC PIM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZarządzanie termiczne:\u003c\/strong\u003e Zachowaj wolne drogi przepływu powietrza wokół obudowy, aby zapewnić, że temperatura otoczenia nie przekroczy projektowego limitu +65°C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666619298155,"sku":"3500\/15-04-04 114M5330-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-04-04-114m5330-01-power-supply-5k35pxxvdye_c27aac77-1ccb-4ed2-961f-aed70c79263b.jpg?v=1765444237"},{"product_id":"bently-nevada-114m5330-01-3500-15-ac-and-dc-power-supply-module","title":"Moduł zasilania AC i DC Bently Nevada 114M5330-01 3500\/15","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e114M5330-01\u003c\/strong\u003e to wysokiej niezawodności, półwysokości \u003cstrong\u003emoduł zasilania prądu przemiennego i stałego\u003c\/strong\u003e zaprojektowany dla matrycy ochrony maszyn \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e. Ten niezbędny moduł konwersji zasilania montuje się w wyznaczonych gniazdach po lewej stronie obudowy szafy 3500, przekształcając szeroki zakres napięć wejściowych na wysoce regulowane, niskoszumowe szyny DC wymagane przez sąsiednie karty monitorujące i przetwarzające logikę. Pojedynczy moduł \u003cstrong\u003e114M5330-01\u003c\/strong\u003e jest w pełni zdolny do zasilania całej, gęstej struktury szafy 3500 samodzielnie.\u003c\/p\u003e\n\u003cp\u003eDla krytycznej infrastruktury wymagającej maksymalnej dostępności zasobów, konfiguracja szafy pozwala na integrację podwójnego zasilania. W systemie redundantnym karta o połowie wysokości pełni funkcję zasilania podstawowego, podczas gdy górny moduł pozostaje w aktywnym trybie zapasowym na gorąco. W przypadku awarii źródła podstawowego moduł zapasowy natychmiast przejmuje pełne obciążenie bez przerw w danych, degradacji sygnału czy zakłóceń w sieciach bezpieczeństwa blokad maszyn. Ta nowoczesna wersja sprzętu cechuje się wyższą efektywnością niż starsze modele i posiada niezależne wskaźniki \"SUPPLY OK\" na przednim panelu dla szybkiej diagnostyki stanu.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eArchitektura z podwójną redundancją umożliwiająca wymianę modułów na gorąco bez zakłócania aktywnej logiki szafy.\u003c\/li\u003e\n\u003cli\u003eWydajne filtrowanie szerokiego zakresu wejściowego do tłumienia silnych skoków napięcia i zakłóceń EMI.\u003c\/li\u003e\n\u003cli\u003eDedykowana dioda LED SUPPLY OK na przednim panelu zapewniająca natychmiastową diagnostykę pętli regulacji wewnętrznej.\u003c\/li\u003e\n\u003cli\u003eObudowa o połowie wysokości zoptymalizowana do układania strukturalnego po lewej stronie standardowej ramy systemu 3500.\u003c\/li\u003e\n\u003cli\u003eZintegrowana ochrona przed przepięciami i zwarciami zabezpiecza delikatne procesory instrumentów po stronie odbiorczej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDostarczanie wysoce stabilizowanego, redundantnego zasilania instrumentów w systemach ochrony turbin o dużej gęstości.\u003c\/li\u003e\n\u003cli\u003eCiągła infrastruktura zasilania pętli bezpieczeństwa w dużych turbinach parowych i krytycznych sprężarkach procesowych.\u003c\/li\u003e\n\u003cli\u003eWysokodostępne kondycjonowanie zasilania w lokalnych panelach morskich, pomp rurociągowych i panelach rozdzielczych do wytwarzania energii.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReferencja zamówienia produktu\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGłówne oznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15 (Zasilacze prądu przemiennego i stałego)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentyfikator części sprzętowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114M5330-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpcja typu modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniwersalny moduł zasilania AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114M5330-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł zasilania AC i DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat obudowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł o połowie wysokości (pasuje do górnych lub dolnych gniazd po lewej stronie)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKonfiguracja redundancji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObsługiwane przez parowanie hot-standby (dolne = podstawowe, górne = zapasowe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego (uniwersalne AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 do 264 Vac, nominalnie 110 do 220 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres częstotliwości wejściowej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 do 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSzyny rozdziału napięcia wyjściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWewnętrzne wyjścia DC wieloszynowe dopasowane do backplane 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOcena izolacji galwanicznej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimalna izolacja ścieżki wejście-wyjście 3000 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWydajność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWysokowydajna topologia przełączająca z zoptymalizowanym rozpraszaniem ciepła\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElement wyświetlacza przedniego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZielona dioda LED „SUPPLY OK”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja szerokości modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja wysokości modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm (architektura o połowie wysokości)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja głębokości modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e242,0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŚrednia waga komponentu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,77 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wilgotności względnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksymalna wilgotność 95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWarstwa interfejsu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED na przedniej płycie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZielona kontrolka SUPPLY OK sygnalizująca prawidłową regulację napięcia wewnętrznego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfejs złącza tylnego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWielopinowy blok ostrzy łączący się bezpośrednio z modułem zasilania (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePołączenie magistrali backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWewnętrzne łącza śledzące dostarczające regulowane zasilanie przez gniazda szafy 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWkładanie modułu do szafy:\u003c\/strong\u003e Ostrożnie wsuwaj moduł o połowie wysokości w wyznaczone gniazda po lewej stronie ramy szafy 3500. Mocno osadź kartę w tylnym backplane i dokręć śruby na przedniej płycie ręcznie.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMapowanie gniazd redundantnych:\u003c\/strong\u003e Zainstaluj podstawowy zestaw zasilacza w dolnym gnieździe, a opcjonalną jednostkę zapasową umieść w górnym gnieździe bezpośrednio nad nim.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonserwacja Hot-Swap:\u003c\/strong\u003e Jeśli system z podwójnym zasilaniem jest włączony, możesz usunąć uszkodzony zasilacz lub odpowiadający mu tylny moduł zasilania (PIM) bez wyłączania szafy lub przerywania ochrony maszyn.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eŚrodki zapobiegawcze ESD:\u003c\/strong\u003e Zawsze przypinaj zatwierdzoną opaskę antystatyczną do niepomalowanej ramy szafy przed wyjmowaniem lub obsługą płytek drukowanych, aby chronić wrażliwe komponenty przed wyładowaniami elektrostatycznymi.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666768327019,"sku":"3500\/15 114M5330-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-114m5330-01-low-voltage-dc-pim-jdiabnmgabf_8b202e3e-5ae2-414c-af3e-38a332082979.jpg?v=1765447245"},{"product_id":"bently-nevada-135473-01-3500-25-keyphasor-i-o-module-internal-barriers","title":"Moduł wejścia\/wyjścia Bently Nevada 135473-01 3500\/25 Keyphasor (wewnętrzne bariery)","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eBently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto specjalistyczny moduł I\/O o połowie wysokości zaprojektowany dla systemu\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced Keyphasor. Ta konkretna konfiguracja integruje\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBariery Wewnętrzne\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoraz\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eZakończenia Wewnętrzne\u003c\/strong\u003e, zapewniając sprzętowy interfejs bezpieczeństwa wewnętrznego dla przetworników umieszczonych w strefach zagrożonych. Moduł jest zaprojektowany do odbioru i przetwarzania sygnałów impulsowych raz na obrót lub wielokrotnie na obrót z sond zbliżeniowych lub czujników magnetycznych, które są niezbędne do obliczania prędkości obrotowej maszyny oraz dostarczania odniesienia fazowego do analizy drgań.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epełni funkcję fizycznego interfejsu w szafie 3500, zapewniając izolację elektryczną i kondycjonowanie sygnału dla krytycznej ochrony maszyn. Chociaż moduł obsługuje pomiary fazy, jest zoptymalizowany do monitorowania prędkości wału z wysoką dokładnością. Korzystając z wersji z barierą wewnętrzną, moduł zapewnia bezpieczny punkt połączenia, który ogranicza energię elektryczną wysyłaną do czujników polowych, spełniając rygorystyczne przemysłowe normy bezpieczeństwa dla atmosfer wybuchowych.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuł I\/O Keyphasor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeria 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp zakończenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZakończenia wewnętrzne\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfejs bezpieczeństwa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBariery wewnętrzne (typ Zenera)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKanały wejściowe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 sygnały przetworników (proximity lub czujnik magnetyczny)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypowo 3,2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum 21,8 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZakres sygnału (bez izolacji)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+0,8 V do -21,0 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimalna prędkość czujnika magnetycznego\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003e 200 obr.\/min (3,3 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 103,1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,46 kg (1,01 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C do +65°C (32°F do +150°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% bez kondensacji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cp\u003eZakupy przemysłowe powinny koncentrować się na konkretnym numerze części, aby zapewnić kompatybilność z konfiguracją monitora 3500\/25.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e: Moduł I\/O Keyphasor z barierami wewnętrznymi i zakończeniami wewnętrznymi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStan\u003c\/strong\u003e: Nowy oryginalny\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDostępność\u003c\/strong\u003e: Magazyn części zamiennych\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł może zapewnić izolację dla aplikacji Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, jest kompatybilny z aplikacjami Proximitor, ale wymaga zewnętrznego zasilania do zapewnienia izolacji.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJaki jest główny cel projektowy wersji z izolowanym I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZostał stworzony specjalnie do zastosowań z czujnikami magnetycznymi, gdzie sygnały są podłączone równolegle do wielu urządzeń, takich jak systemy sterowania.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCo się dzieje, gdy sygnały wejściowe przekraczają określony zakres?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSygnały przekraczające określony zakres napięcia są wewnętrznie ograniczane przez obwody modułu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOdwołanie techniczne: Okablowanie, zwory i specyfikacje\u003c\/h3\u003e\n\u003ch3\u003e1. OKABLOWANIE KANAŁU I DEFINICJE PINÓW\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ejest wewnętrznym modułem zakończenia I\/O z wbudowanymi barierami galwanicznymi. Posiada dwa niezależne listwy zaciskowe dla Kanału 1 i Kanału 2.\u003c\/p\u003e\n\u003ch4\u003eA. Okablowanie czujnika zbliżeniowego (3-przewodowe)\u003c\/h4\u003e\n\u003cp\u003eDla standardowych czujników prądów wirowych (np. seria 3300 XL):\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR (-24V):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWyjście zasilania dla Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM (GND):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWspólny\/zwrotny sygnał.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG (OUT):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWejście sygnału napięciowego impulsu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Okablowanie czujnika magnetycznego (pasywne 2-przewodowe)\u003c\/h4\u003e\n\u003cp\u003eDla samogenerujących elektromagnetycznych czujników prędkości:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz do dodatniego (+) przewodu czujnika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz do ujemnego (-) przewodu czujnika.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMuszą pozostać odłączone (pływające).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Ekranowanie i uziemienie IS\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSHLD (Ekran):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz ekrany kabli polowych do tego dedykowanego zacisku.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUziemienie IS :\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModuł ten musi być uziemiony przez\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01 Moduł uziemienia bariery\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edo dedykowanej szyny uziemienia bezpieczeństwa iskrobezpiecznego, aby zapewnić integralność przeciwwybuchową.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. KONFIGURACJE ZWOREK SPRZĘTOWYCH\u003c\/h3\u003e\n\u003cp\u003eZworki znajdują się na wewnętrznej płytce drukowanej i muszą być ustawione przed instalacją.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eZworka zasilania przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eZworka sprzęgająca wejście\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunkcja logiczna\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCzujnik zbliżeniowy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eINT\u003c\/strong\u003e (Wewnętrzny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC\u003c\/strong\u003e (Prąd stały)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDostarcza zasilanie; umożliwia polaryzację DC.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCzujnik magnetyczny\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEXT\u003c\/strong\u003e (Zewnętrzny\/WYŁĄCZONY)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC\u003c\/strong\u003e (Prąd zmienny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOdłącza zasilanie; filtruje szumy DC.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eWAŻNE:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eZawsze wyłącz zasilanie szafy 3500 lub usuń moduł monitorujący przed regulacją zworek, aby uniknąć łuku elektrycznego.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr\u003e\n\u003ch3\u003e3. PODSTAWOWE SPECYFIKACJE WYDAJNOŚCI\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePojemność kanału:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 niezależne kanały wejściowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZakres częstotliwości:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 do 1 200 000 cpm (\u003cstrong\u003e0,017 Hz do 20 kHz\u003c\/strong\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZakres napięcia wejściowego:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+5V do -11V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(specjalnie dla Barier I\/O).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTryby kondycjonowania:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg automatyczny:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMinimalny sygnał 2 V szczyt-szczyt; minimalna prędkość 120 obr.\/min.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg ręczny:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegulowany od 0 do -20 V DC; minimalny sygnał 500 mV; obsługuje niskie prędkości do 1 obr.\/min.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eŚrodowiskowe:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eZużycie energii:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3,2 Waty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(typowe).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperatura pracy:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0°C do 65°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. CERTYFIKATY STREF ZAGROŻONYCH\u003c\/h3\u003e\n\u003cp\u003eZaprojketowany do środowisk wysokiego ryzyka:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmeryka Północna:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKlasa I, Div 2, Grupy A, B, C, D.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEuropa (ATEX):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eII 1 G [EEx ia] IIC (Wejścia ocenione na Strefę 0).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e5. WSPARCIE KONFIGURACJI SYSTEMU\u003c\/h3\u003e\n\u003cp\u003ePo fizycznej instalacji użyj\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoprogramowania do konfiguracji szafy 3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaby zweryfikować:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUstawienia histerezy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAby zapobiec fałszywym wyzwoleniom na zakłóconych sygnałach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrientacja:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUstawienie kierunku impulsu (dodatni\/ujemny).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAktywne kanały:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eZapewnienie zgodności ustawień zworki w oprogramowaniu z fizycznymi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCZĘŚĆ 2: SCHEMATY ZACISKÓW I KONFIGURACJA OPROGRAMOWANIA\u003c\/h3\u003e\n\u003ch3\u003e1. ROZKŁAD PINÓW BLOKU ZACISKÓW (A\/B\/C\/D)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eużywa określonej sekwencji 4 zacisków dla każdego kanału. Poniżej znajduje się mapa połączeń do podłączenia okablowania terenowego:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eZacisk\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEtykieta\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCzujnik zbliżeniowy (3-przewodowy)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCzujnik magnetyczny (2-przewodowy)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePWR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 V DC zasilanie (biały)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBRAK POŁĄCZENIA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWspólny\/masa (czarny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSygnał ujemny (-)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWejście sygnału (czerwony)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSygnał dodatni (+)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSHLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEkranowanie\/przewód odprowadzający\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEkranowanie\/przewód odprowadzający\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e2. KONFIGURACJA OPROGRAMOWANIA (KONFIGURACJA SZAFY 3500)\u003c\/h3\u003e\n\u003cp\u003ePo zainstalowaniu sprzętu musisz skonfigurować następujące elementy w oprogramowaniu:\u003c\/p\u003e\n\u003ch4\u003eA. Ustawienia progu\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg automatyczny\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSystem automatycznie oblicza punkt wyzwalania na poziomie 50% amplitudy sygnału.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNajlepsze dla\u003c\/strong\u003e: Standardowych prędkości pracy (\u0026gt;120 obr.\/min) z czystymi, stałymi impulsami.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePróg ręczny\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRęcznie ustawiasz stałe napięcie (np. -8,0 V DC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrongNajlepsze dla\u003c\/strong\u003e: Rozruchów niskich prędkości lub sygnałów z istotnymi „zakłóceniami” lub szumem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWskazówka dotycząca obliczeń\u003c\/strong\u003e: Ustaw próg na środek między szczytem impulsu a sygnałem bazowym.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Histereza (redukcja szumów)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDla\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eczujników magnetycznych\u003c\/strong\u003e powinieneś ustawić wartość histerezy (zwykle\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0,2V do 0,5V\u003c\/strong\u003e), aby zapobiec „podwójnemu wyzwalaniu” monitora, jeśli sygnał jest zakłócony podczas przekraczania progu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Aktywne zbocze (kierunek)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNegatywne zbocze\u003c\/strong\u003e: Wyzwala, gdy sygnał przechodzi z 0V do -24V (standard dla większości sond Bently).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePozytywne zbocze\u003c\/strong\u003e: Wyzwala, gdy sygnał przesuwa się w kierunku dodatnim.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. KRYTYCZNA LISTA KONTROLNA INSTALACJI\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUziemienie bariery\u003c\/strong\u003e: Upewnij się, że moduł\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ejest zainstalowany w szafie. Bez tego 135473-01 nie może prawidłowo uziemić wewnętrznych barier bezpieczeństwa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKontrola zworki\u003c\/strong\u003e: Podwójnie sprawdź, czy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezworki Kanału 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ei\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKanału 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epasują do odpowiednich czujników. Częstym błędem jest pozostawienie zworki PWR na\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprzy użyciu czujnika magnetycznego, co może powodować zakłócenia lub nagrzewanie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKodowanie\u003c\/strong\u003e: Używaj\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estopni C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoraz\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCelsjusza\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ew swojej dokumentacji technicznej, aby uniknąć problemów z uszkodzonymi znakami, które wcześniej występowały w Twoim CMS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847134059,"sku":"135473-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135473-01-motion-controller-module-with-316l-stainless-steel-case-material-ag55zssqu3e_fe8b3db7-fd2e-41ca-ad85-8851d4d47e88.jpg?v=1765448946"},{"product_id":"bently-nevada-82365-01-dual-epoxy-relays","title":"Przekaźniki podwójne epoksydowe Bently Nevada 82365-01","description":"\u003cp\u003eModuł przekaźnikowy alarmowy \u003cstrong\u003e82365-01\u003c\/strong\u003e to komponent sprzętowy montowany z tyłu, z dwoma kanałami, zaprojektowany specjalnie dla systemu ochrony maszyn Bently Nevada 3300. Umieszczony bezpośrednio za poszczególnymi monitorami maszyn w tylnej części szafy instrumentów 3300, moduł przekształca elektroniczne sygnały ostrzegawcze i stany zagrożenia monitora na fizyczne wyjścia stykowe za pomocą dwóch przekaźników zalanych epoksydem. Ta podwójna, epoksydowa konstrukcja zapewnia wysoką odporność na zanieczyszczenia atmosferyczne, utlenianie i wilgoć, gwarantując solidną izolację galwaniczną oraz niezawodne przełączanie dla zewnętrznych obwodów wyłączania maszyn, rozproszonych systemów sterowania (DCS) lub systemów awaryjnego wyłączania (ESD). W każdej obudowie systemu 3300 wymagana jest co najmniej jedna konfiguracja modułu przekaźnikowego alarmowego do obsługi krytycznej logiki ochrony maszyn.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje sprzętowe\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82365-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeria produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł przekaźnikowy alarmowy z dwoma kanałami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzekaźniki mechaniczne zalane epoksydem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKonfiguracja kanałów\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 niezależne kanały (podwójne)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForma \/ miejsce montażu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMontaż z tyłu szafy (za poszczególnymi monitorami)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOchrona środowiskowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObudowa epoksydowa odporna na wilgoć i gazy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymaganie systemowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 1 moduł przekaźnikowy na szafę systemu 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUwaga dotycząca zamówień ATEX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardowa część zamienna bez certyfikatu ATEX (patrz opcje w nawiasach dla ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUwagi inżynierskie\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePodwójne przekaźniki epoksydowe działają na zasadzie bezpośredniej logiki sterowania z monitora 3300 zamontowanego z przodu, zmieniając stan natychmiast po przekroczeniu progów Ostrzeżenia lub Zagrożenia.\u003c\/li\u003e\n\u003cli\u003eObudowa epoksydowa izoluje wewnętrzne styki elektryczne od korozyjnych czynników przemysłowych, minimalizując degradację rezystancji styków podczas długiego okresu eksploatacji.\u003c\/li\u003e\n\u003cli\u003eModuł ten służy jako standardowa część zamienna; w zastosowaniach wymagających zgodności z ATEX należy użyć wariantu z odpowiednią europejską certyfikacją.\u003c\/li\u003e\n\u003cli\u003eNależy zapewnić zgodność położenia modułu w szafie z konfiguracją monitora, aby uniknąć błędów logicznego mapowania kanałów na magistrali tylnej płyty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWytyczne montażowe\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrzed włożeniem lub wyjęciem modułu przekaźnikowego montowanego z tyłu należy całkowicie odłączyć zasilanie szafy systemu 3300, aby zapobiec powstawaniu łuków elektrycznych na magistrali.\u003c\/li\u003e\n\u003cli\u003eWszystkie przewody sterujące i wyjścia alarmowe należy prowadzić przez dedykowane listwy zaciskowe, zachowując wyraźne rozdzielenie fizyczne między sygnałami niskonapięciowymi a obwodami przełączania wysokiego napięcia przekaźników.\u003c\/li\u003e\n\u003cli\u003ePołączenia przewodów do zacisków przekaźników nie mogą przekraczać określonych maksymalnych wartości prądu i napięcia, aby zapobiec trwałemu zgrzaniu styków lub uszkodzeniu ścieżek na płytce modułu.\u003c\/li\u003e\n\u003cli\u003ePodczas instalacji należy sprawdzić integralność prowadnic tylnej obudowy, aby zapewnić pełne i równomierne osadzenie pinów modułu w złączach tylnej płyty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ techniczne i zakupowe\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Gdzie dokładnie jest fizycznie zainstalowany moduł przekaźnikowy 82365-01 w systemie monitorowania maszyn?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Moduł jest montowany na tylnej płycie szafy Bently Nevada 3300, bezpośrednio za monitorem, którego logikę alarmową ma obsługiwać.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy ten konkretny numer części może być używany bezpośrednio jako część zamienna w zakładzie przemysłowym wymagającym certyfikatu ATEX?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Nie, 82365-01 to standardowa część zamienna bez certyfikatu ATEX; konfiguracje do stref zagrożenia wymagają zamówienia odpowiedniej opcji z certyfikatem ATEX wskazanej w instrukcji systemu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy system monitorowania 3300 działa poprawnie bez zainstalowanych modułów przekaźnikowych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Chociaż wskaźniki na panelu przednim wyświetlą wartości, co najmniej jeden moduł przekaźnikowy musi być zainstalowany w systemie, aby zapewnić fizyczne styki niezbędne do sterowania zewnętrznymi obwodami awaryjnego wyłączania i alarmów.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847527275,"sku":"82365-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-82365-01-recorder-outputs-u55nmbzrgzd_7b85959d-e35e-499e-a6c2-0f3c4e7de0b9.jpg?v=1765448963"},{"product_id":"bently-nevada-125712-01-spare-4-channel-relay-module","title":"Moduł zapasowy 4-kanałowego przekaźnika Bently Nevada 125712-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e125712-01\u003c\/strong\u003e to moduł pełnowymiarowy zapasowy, zaprojektowany do zapewnienia czterech niezależnych programowalnych wyjść przekaźnikowych w systemie ochrony maszyn. Funkcjonuje jako podstawowy element systemu \u003cstrong\u003e3500\/32\u003c\/strong\u003e, umożliwiając użytkownikowi programowanie logiki głosowania do uruchamiania określonych automatycznych alarmów na podstawie stanu maszyny. Każde wyjście integruje \u003cstrong\u003elogikę sterowania alarmami\u003c\/strong\u003e, pozwalającą na złożone konfiguracje bramek AND i OR wykorzystujące sygnały ostrzegawcze i niebezpieczeństwa zbierane z dowolnej kombinacji kanałów monitorujących w tej samej szafie. Moduł współpracuje bezproblemowo z dopasowanymi płytkami końcowymi do płyty tylnej, aby uruchamiać systemy bezpieczeństwa, mechanizmy awaryjnego wyłączania lub zewnętrzne wskaźniki dla różnych wysoko krytycznych obracających się zasobów.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCztery niezależne, wysoce konfigurowalne kanały przekaźnikowe zdolne do przetwarzania indywidualnej logiki głosowania zasobów.\u003c\/li\u003e\n\u003cli\u003eZaawansowana \u003cstrong\u003elogika sterowania alarmami\u003c\/strong\u003e obsługująca kombinacje bramek AND\/OR dla optymalizacji sekwencji wyłączeń ochronnych.\u003c\/li\u003e\n\u003cli\u003eElastyczne umiejscowienie w slocie, umożliwiające instalację w dowolnym dostępnym slocie po prawej stronie modułu interfejsu szafy.\u003c\/li\u003e\n\u003cli\u003eKompleksowe wskaźniki diagnostyczne na panelu przednim pokazujące stan pracy (OK), aktywną komunikację szafy (TX\/RX) oraz niezależne stany alarmowe kanałów.\u003c\/li\u003e\n\u003cli\u003eWbudowane tłumiki łuku elektrycznego standardowo wyposażone do bezpiecznego tłumienia przepięć na wyjściach.\u003c\/li\u003e\n\u003cli\u003eŁatwe programowanie za pomocą specjalistycznego oprogramowania, dostosowane do wymagań systemu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePętle ochronne dla szybkich maszyn turbomachinowych i sprężarek.\u003c\/li\u003e\n\u003cli\u003eAutomatyczne sterowanie logiką bezpieczeństwa dla urządzeń do wytwarzania energii i pomp przemysłowych.\u003c\/li\u003e\n\u003cli\u003eInterfejsowanie wskaźników krytycznych stanów z systemami sterowania rozproszonym (\u003cstrong\u003eDCS\u003c\/strong\u003e) oraz systemami awaryjnego wyłączania (\u003cstrong\u003eESD\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eWielokanałowe systemy monitorowania drgań, w których logiczne kryteria głosowania zapobiegają fałszywym wyłączeniom procesów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNumer części \/ kod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/32-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKonfiguracja kompletnego zespołu modułu przekaźnikowego 4-kanałowego.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O przekaźnikowy 4-kanałowy.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: Brak.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: CSA\/NRTL\/C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125712-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzęści zamienne:\u003c\/strong\u003e Zapasowy moduł przekaźnikowy 4-kanałowy.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125720-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzęści zamienne:\u003c\/strong\u003e Zapasowy moduł I\/O przekaźnikowy 4-kanałowy.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e132319-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzęści zamienne:\u003c\/strong\u003e Układ scalony firmware.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580436\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzęści zamienne:\u003c\/strong\u003e Gniazdo złączowe, wewnętrzne zakończenie, 6-pozycyjne, zielone.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKategoria parametru\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKod modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części zamiennej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e125712-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo 6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKonfiguracja przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDwa przekaźniki jednobiegunowe, dwustykowe (SPDT) połączone w konfigurację dwubiegunową, dwustykową (DPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp uszczelnienia przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUszczelnienie epoksydowe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTłumik łuku\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms, montowany jako standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŻywotność styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 000 cykli przy 5 A, 24 Vdc lub 120 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTryb pracy kanału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTryb pracy kanału wybierany przełącznikiem: normalnie rozłączony lub normalnie załączony\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoc przełączana rezystancyjna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaks. prąd stały: 120 W | Maks. prąd przemienny: 600 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie przełączane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100mA przy 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny prąd przełączany\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaksymalne napięcie przełączane\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eprąd stały: 30 Vdc | prąd przemienny: 250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 242 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,7 kg (1,6 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,4 kg (1,0 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania dotyczące gniazd w szafie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowysokie przednie gniazdo dla modułu głównego, 1 pełnowysokie tylne gniazdo dla modułów I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cp\u003eKonfiguracje interfejsu zapewniają dedykowane odczyty diagnostyczne i terminale stykowe dla niezawodnego sygnalizowania pętli:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eElement interfejsu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja \/ Przypisanie\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWskaźnik na panelu przednim; pozostaje zapalony, gdy wewnętrzny obwód działa prawidłowo.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWskaźnik na panelu przednim; miga ciągle, aby pokazać normalną aktywność komunikacji szyny tylnej szafy.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED ALARM KANAŁU (1 - 4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNiezależne wskaźniki; zapalają się bezpośrednio, gdy odpowiadający kanał przekaźnika wywołuje stan alarmowy.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminale wyjściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBloki połączeń przewodów na tylnej płycie służące do łączenia punktów styku z systemami automatyki zakładowej.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrzełączniki sprzętowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWbudowane mechanizmy sterujące służące do definiowania podstawowego stanu operacyjnego styków wyjściowych.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePozycjonowanie modułu:\u003c\/strong\u003e Wsuń komponent do pojedynczego, pełnowysokiego przedniego gniazda obudowy głównej, umieszczając go po prawej stronie głównej karty interfejsu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOchrona przed wyładowaniami elektrostatycznymi (ESD):\u003c\/strong\u003e Przed dotknięciem lub obsługą płytek obwodów, załóż zatwierdzony antystatyczny pasek uziemiający na nadgarstek, aby zmniejszyć ryzyko niezamierzonego wyładowania elektrostatycznego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMapowanie logiki:\u003c\/strong\u003e Otwórz niestandardowe narzędzie, aby ustalić docelowe mapy wyzwalania przed testowaniem kanałów wyjściowych systemu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWybór stanu:\u003c\/strong\u003e Ręcznie ustaw fizyczne przełączniki konfiguracyjne, aby wybrać stan normalnie załączony lub normalnie wyłączony przed uruchomieniem pętli przekaźnikowych wyjściowych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyłączenie TMR:\u003c\/strong\u003e Należy zauważyć, że standardowe opcje czterokanałowe nie nadają się do pętli potrójnej redundancji modularnej; zastosuj odpowiedni dedykowany model zespołu głosującego dla architektury ochrony TMR.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmisje EMC:\u003c\/strong\u003e EN50081-2, EN 55011 Klasa A (emisje przewodzone i promieniowane).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOdporność EMC:\u003c\/strong\u003e EN50082-2, EN 61000-4-2 (kryteria ESD B), ENV 50140 (kryteria podatności na promieniowanie A), ENV 50141 (kryteria podatności przewodzonej A), EN 61000-4-4 (kryteria EFT B), EN 61000-4-5 (kryteria przepięć B), EN 61000-4-8 (kryteria pola magnetycznego A), EN 61000-4-11 (kryteria spadków napięcia B), ENV 50204 (kryteria radiotelefonu B).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy niskonapięciowe:\u003c\/strong\u003e EN 61010-1 Wymagania bezpieczeństwa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy dotyczące stref zagrożenia:\u003c\/strong\u003e CSA\/NRTL\/C Klasa I, Podział 2, Grupy A do D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest zasadnicza różnica między tym zapasowym elementem a standardowym kodem zamówienia 3500\/32?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3500\/32 opisuje ogólną rodzinę funkcjonalną lub konfigurację systemu wieloelementowego, podczas gdy odrębny numer części definiuje indywidualną, wymienną na gorąco przednią kartę dostarczaną jako element zamienny.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy te kanały przekaźnikowe można ręcznie przypisać do alarmów na dowolnej karcie monitorującej drgania w tym samym systemie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, wewnętrznie przechowywany algorytm przetwarzania pobiera sygnały operacyjne i stany alarmowe z dowolnej kombinacji standardowych slotów w aktywnej konfiguracji szafy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak dostosować kanał przekaźnika między stanem normalnie załączonym a normalnie wyłączonym?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDocelowa konfiguracja wymaga regulacji poszczególnych fizycznych przełączników sprzętowych znajdujących się na zespole oraz dostosowania parametrów w narzędziu konfiguracyjnym.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy standardowy komponent 125712-01 jest dostarczany z odpowiadającym mu tylnym modułem wejścia\/wyjścia?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie, ten numer części oznacza wyłącznie przednią kartę głównego procesora; jeśli potrzebna jest tylna płyta zakończeniowa, należy ją zamówić pod jej indywidualnym numerem produktu.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847658347,"sku":"3500\/32 125712-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-32-125712-01-4-channel-relay-module-apgs2pgvaqc_1bd7426c-4cca-42dc-afd3-fce09079cbbe.jpg?v=1765448967"},{"product_id":"bently-nevada-3500-33-04-00-149992-04-low-current-16-channel-failsafe-relay-output-module","title":"Bently Nevada 3500\/33-04-00 149992-04 Low Current 16-Channel Failsafe Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/33-04-00 149992-04\u003c\/strong\u003e is a \u003cstrong\u003e16-channel failsafe relay output module\u003c\/strong\u003e used as a main or spare module in \u003cstrong\u003e3500 machinery protection systems\u003c\/strong\u003e. It provides 16 independently programmable relay outputs with alarm drive logic, supporting AND\/OR logic combinations of alert, danger, Not-OK statuses, and measured variables from any monitor channel. Each relay output can perform voting logic and integrates with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module interfaces with \u003cstrong\u003ePLC, DCS, SIS, and TSI systems\u003c\/strong\u003e, offering both normally de-energized (ND) and normally energized (NE) operation selectable in four groups of four channels. Front-panel LEDs indicate module status, communication activity, and channel alarm states.\u003c\/p\u003e\n\u003cp\u003eIt supports low current switching applications with gold-plated contacts, suitable for standard, failsafe, or hazardous area configurations. Module compatibility includes installation to the right of the Transient Data Interface (TDI) in a \u003cstrong\u003e3500 rack\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 relay outputs with independent programmable logic\u003c\/li\u003e\n\u003cli\u003eAlarm drive logic using AND\/OR conditions\u003c\/li\u003e\n\u003cli\u003eSelectable normally de-energized (ND) or normally energized (NE) operation\u003c\/li\u003e\n\u003cli\u003eFront-panel LEDs for OK, TX\/RX, and channel alarm status\u003c\/li\u003e\n\u003cli\u003eEpoxy-sealed relays with arc suppressors (250 Vrms)\u003c\/li\u003e\n\u003cli\u003eRelay life up to 10,000 cycles\u003c\/li\u003e\n\u003cli\u003eLow current gold-plated contact option for 1 mA @ 1 Vdc minimum load\u003c\/li\u003e\n\u003cli\u003eCompatible with 3500 Rack Configuration Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial machinery monitoring and protection\u003c\/li\u003e\n\u003cli\u003eProcess automation alarm outputs\u003c\/li\u003e\n\u003cli\u003eHazardous area relay interfacing\u003c\/li\u003e\n\u003cli\u003eIntegration with PLC, DCS, SIS, TSI systems\u003c\/li\u003e\n\u003cli\u003eLow-current signal switching in control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/33-04-00: Complete 16-Channel Relay Module Assembly\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifies the pre-configured combination consisting of the front main module card and the rear low-current failsafe output board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04: Output Module Type Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLow Current 16-Channel Failsafe Relay Output Module featuring gold-plated contacts (Rear I\/O Module Spare: \u003cstrong\u003e149992-04\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Hazardous Area Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo hazardous area agency approvals or certifications required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpares \u0026amp; Accessories\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number \u003cstrong\u003e149992-04\u003c\/strong\u003e: Spare 16-Channel Low Current Failsafe Relay Output Module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMain module: 0.7 kg (1.6 lb), I\/O module: 0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMain module: 241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in), I\/O module: 241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003eMain: 1 full-height front slot, I\/O: 1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSPDT (Single-pole Double-throw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Arc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003eStandard: 100 mA @ 5 Vdc, Low Current: 1 mA @ 1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003eDC: 5 A, AC: 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Power\u003c\/td\u003e\n\u003ctd\u003eDC: 70 W @ 24 Vdc, AC: 1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003eDC: 125 Vdc, AC: 250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eOK, TX\/RX, CH Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/D-Agent_1-_work-77-s-Upload-162096J1.pdf?v=1780026391\"\u003eRefer to 3500 rack manual\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay outputs, power, communication connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eGrounding and Shielding\u003c\/h4\u003e\n\u003cp\u003eEnsure the rack frame is properly tied to the plant instrumentation ground before inserting modules. Field wiring shields should be terminated at the designated shield terminals on the I\/O module to minimize electromagnetic interference and ensure signal integrity.\u003c\/p\u003e\n\u003ch4\u003eHazardous Area Precautions\u003c\/h4\u003e\n\u003cp\u003eDo not disconnect field wiring or module connections while the circuit is live unless the location is verified to be non-hazardous. Live handling in explosive atmospheres can result in arc-induced ignition risks.\u003c\/p\u003e\n\u003ch4\u003eModule Placement\u003c\/h4\u003e\n\u003cp\u003eAlign the main module with the chosen front slot to the right of the TDI module. Slide it firmly into the backplane connectors and tighten the panel screws. Install the matching I\/O module in the corresponding slot directly on the rear of the rack assembly.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 04 option signify in this module part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e The 04 code specifies that this is the Low Current 16-Channel Failsafe variant equipped with gold-plated contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum current rating for the gold-plated contact version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum switched current rating is 1 mA @ 1 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix the configuration for Normally Energized and Normally De-energized modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the sixteen channels are split into four distinct groups of four channels, and each group is independently switch-selectable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the TX\/RX LED on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TX\/RX LED flashes to indicate active transmission and reception of communication data between this module and other rack modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware package contain built-in spark protection for the contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, an internal 250 Vrms epoxy-sealed relay arc suppressor is standard equipment on the hardware channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit process individual variables from multiple monitor modules at once?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the Alarm Drive Logic can combine Alert, Danger, or Not-OK inputs from any monitor channel or combination of monitor channels within the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software tool is required to configure the voting logic pathways?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system logic is engineered and uploaded using the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the relay operation if the module encounters an internal failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Failsafe design ensures that when a major failure or loss of control occurs, the relays drop to their safe de-energized or default state depending on wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to exceed 5 mA when using an AC supply voltage up to 120Vac?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, currents exceeding 5 mA on these low-current gold relays will degrade or permanently damage the contact plating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many slots does the complete main and I\/O assembly take up?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt occupies one full-height slot on the front of the rack and one corresponding full-height slot on the rear panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I plug this module into the slot immediately adjacent to the power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt must be placed in any available slot situated to the right of the Transient Data Interface module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a solid light on the OK LED indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA solid light confirms that the hardware is powered up, has passed initial self-tests, and is operating properly.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848837995,"sku":"3500\/33-04-00 149992-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-04-00-149992-04-relay-i-o-module-fkulr4tcehu_c36c9898-9ec7-4d81-a6b1-b3299e531e38.jpg?v=1765448997"},{"product_id":"bently-nevada-3500-32m-149986-02-4-channel-relay-module","title":"Bently Nevada 3500\/32M 149986-02 4-Channel Relay Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/32M\u003c\/strong\u003e with spare part number \u003cstrong\u003e149986-02\u003c\/strong\u003e is a full-height module that delivers four highly configurable relay outputs for auto-trip execution and interlocking machinery protection. This \u003cstrong\u003e3500\/32M 149986-02\u003c\/strong\u003e module populates any designated slot located to the right of the Transient Data Interface (TDI) module inside a standard 3500 rack. Each relay output operates independently and can be programmed with sophisticated Alarm Drive Logic, integrating complex AND\/OR voting logic combinations that evaluate Alert, Danger, Not-OK, and individual Proprietary Logic (PPL) variables sourced from any channel or group of channels across the protection chassis via the configuration utility.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour fully independent single-pole double-throw (SPDT) relay channels.\u003c\/li\u003e\n\u003cli\u003eCustom voting configurations utilizing comprehensive onboard Alarm Drive Logic functions.\u003c\/li\u003e\n\u003cli\u003eFactory-installed 250 Vrms arc suppressors on each channel as a standard build feature.\u003c\/li\u003e\n\u003cli\u003eHardware-switch-selectable operations allowing independent Normally De-energized or Normally Energized assignments.\u003c\/li\u003e\n\u003cli\u003eFront panel status tracking via distinct OK, TX\/RX, and individual CH ALARM LEDs.\u003c\/li\u003e\n\u003cli\u003eSealed contact assemblies featuring epoxy protection barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency machinery shutdown loop initiation for industrial rotating equipment.\u003c\/li\u003e\n\u003cli\u003eFunctional safety (SIL) machine trip systems.\u003c\/li\u003e\n\u003cli\u003eCritical multi-channel voting interlock setups for high-speed gas or steam turbines.\u003c\/li\u003e\n\u003cli\u003eHazardous zone status annunciator signaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpare Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e149986-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel Relay Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, double-throw (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArc Suppression\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms installed as standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Life Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles @ 5 A, 24 Vdc or 240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Minimum Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard DC Contact Rating (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 0V to 30 Vdc, 0.75 A @ 48 Vdc, 0.2 A @ 125 Vdc (125 Vdc max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard AC Contact Rating (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 250 Vac max (450 VA max switched power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\/Hazardous Minimum Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\/Hazardous DC Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 0V to 30 Vdc (30 Vdc maximum switched voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\/Hazardous AC Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 30 Vac maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 242 mm (9.50 in. x 0.96 in. x 9.52 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in. x 0.96 in. x 3.90 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Space Allocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot (Main), 1 full-height rear slot (I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Selection:\u003c\/strong\u003e Slide the full-height front module into any available user slot located to the right of the Transient Data Interface (TDI) module inside the 3500 chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Connection Assembly:\u003c\/strong\u003e Align and seat the matching 4-channel relay I\/O module in the corresponding full-height rear slot directly behind the main control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Operating Setup:\u003c\/strong\u003e Adjust the onboard physical switches to define the baseline state as Normally De-energized (ND) or Normally Energized (NE) for each individual channel before field wiring is tied in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Retention:\u003c\/strong\u003e Secure the front-panel panel fasteners fully to ground the module housing properly to the chassis structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Integration:\u003c\/strong\u003e Establish connection parameters, input tracking channels, and custom AND\/OR structures using the 3500 Rack Configuration Software prior to going live.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Precautions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Restriction Compliance:\u003c\/strong\u003e When used in systems ordered with hazardous area approvals (Division 2\/Zone 2 certified), the relay voltages must be strictly restricted to a maximum of 30 Vdc or 30 Vac. The module layout does not support standard increased physical spacing rules required for higher operating voltages under these certifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety (SIL) Limit:\u003c\/strong\u003e If integrated as a component within an active functional safety (SIL) loop, higher voltages are strictly prohibited. The functional safety certificate mandates adherence to the limited voltage levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Shock Hazard:\u003c\/strong\u003e Isolate all external field wiring and circuits prior to working on terminal strips. This module can expose conductors to potential contact, introducing severe electrical burn or shock hazards under high-voltage configurations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850345323,"sku":"3500\/32M 149986-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-32m-149986-02-4-channel-relay-module-jpukccfwkaz_1a867c4f-eb20-4adb-ab0a-439738ac47ac.jpg?v=1765449025"},{"product_id":"bently-nevada-3500-33-149986-01-16-channel-relay-module","title":"Moduł przekaźnikowy Bently Nevada 3500\/33 149986-01 z 16 kanałami","description":"\n\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eTen \u003cstrong\u003e3500\/33\u003c\/strong\u003e z numerem części zamiennej \u003cstrong\u003e149986-01\u003c\/strong\u003e To moduł pełnowysokościowy, który zapewnia 16 niezależnych programowalnych wyjść przekaźnikowych do ochrony maszyn i przełączania sterowania. \u003cstrong\u003e3500\/33 149986-01\u003c\/strong\u003e Moduł działa w systemie ochrony maszyn serii 3500 i instaluje się w dowolnym standardowym slocie po prawej stronie modułu Transient Data Interface (TDI). Każde wyjście przekaźnikowe posiada niezależną konfigurację logiki głosowania oraz dedykowaną logikę sterowania alarmem, która przetwarza statusy alertu, zagrożenia i Not-OK pochodzące z dowolnej kombinacji kanałów monitorujących w ramach szafy za pomocą oprogramowania konfiguracyjnego. Wewnętrzne śledzenie łącza komunikacyjnego jest wizualnie monitorowane przez zintegrowane wskaźniki na panelu przednim.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 całkowicie niezależnych wyjść przekaźnikowych jednobiegunowych dwutorowych (SPDT).\u003c\/li\u003e\n\u003cli\u003eNiestandardowa logika głosowania i logika sterowania alarmem obsługująca złożone konfiguracje AND\/OR.\u003c\/li\u003e\n\u003cli\u003eZintegrowane tłumiki łuku 250 Vrms jako standardowa ochrona.\u003c\/li\u003e\n\u003cli\u003ePrzełączalne tryby pracy: Normalnie odłączony (ND) lub Normalnie załączony (NE) w grupach po cztery kanały.\u003c\/li\u003e\n\u003cli\u003eWizualna weryfikacja statusu za pomocą diod LED OK, TX\/RX oraz alarmów poszczególnych kanałów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatyczne inicjowanie logiki wyłączania awaryjnego i zatrzymania maszyn.\u003c\/li\u003e\n\u003cli\u003eSterowanie blokadami i panelem sygnalizacyjnym w ciężkich procesach przemysłowych.\u003c\/li\u003e\n\u003cli\u003eSygnalizacja stanu alarmu krytycznego przekaźnikiem dla turbin, dużych pomp i sprężarek przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części zamiennej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e149986-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł sterowania przekaźnikami 16-kanałowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 5,8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp styków przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzełącznik jednobiegunowy dwutorowy (SPDT), uszczelniony epoksydowo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTłumik łuku przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms standardowo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŻywotność styków przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 000 cykli\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandardowe minimalne obciążenie systemu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA przy 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandardowe maksymalne obciążenie DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A, 70 W przy 24 Vdc, 10 W przy 48 Vdc, 9 W przy 60 Vdc, maks. 125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalne obciążenie standardowe AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A, 1200 VA, maks. 250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny prąd systemu bezpiecznego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A, maks. 30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie systemu niskiego prądu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mA przy 1 Vdc (styki pozłacane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny prąd niskiego napięcia DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA przy 48 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalny prąd niskiego napięcia AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaks. 5 mA (dotyczy AC do 120Vac)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 242 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,7 kg (1,6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,4 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagana przestrzeń w szafie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowysokościowy przedni slot (główny), 1 pełnowysokościowy tylny slot (I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmieszczenie w slocie:\u003c\/strong\u003e Umieść moduł główny pełnowysokościowy w dowolnym dostępnym slocie obudowy znajdującym się bezpośrednio po prawej stronie głównego modułu TDI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParowanie redundantne:\u003c\/strong\u003e Sparuj główny moduł przedni z odpowiadającym mu 16-kanałowym modułem przekaźnikowym I\/O umieszczonym bezpośrednio za nim w tylnej części obudowy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramowanie logiki:\u003c\/strong\u003e Skonfiguruj struktury logiki głosowania i parametry operacyjne za pomocą oprogramowania 3500 Rack Configuration Software przed uruchomieniem pętli przyrządu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUstawienie trybu pracy:\u003c\/strong\u003e Ustaw przełączniki fizyczne, aby wybrać między konfiguracją normalnie odłączoną (ND) a normalnie załączoną (NE) dla każdej grupy czterokanałowej zgodnie ze specyfikacjami bezpieczeństwa zakładu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOstrzeżenie o niebezpiecznym napięciu:\u003c\/strong\u003e Upewnij się, że wszystkie punkty okablowania zacisków polowych są całkowicie odizolowane od linii zasilających przed instalacją lub konserwacją, aby wyeliminować ryzyko porażenia wysokim napięciem.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eŚrodek ostrożności przed wybuchem:\u003c\/strong\u003e Nie podłączaj ani nie odłączaj żadnych komponentów ani zakończeń polowych, gdy obwód przyrządu jest aktywny, chyba że otaczająca strefa została zweryfikowana jako niebezpieczna.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666853818731,"sku":"3500\/33 149986-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-149986-01-16-channel-relay-module-2sbgqnjvph0_b2893ac9-ef71-49a3-a945-cf757d7e2ad2.jpg?v=1765449122"},{"product_id":"bently-nevada-3300-12-power-supply-module","title":"Zasilacz AC Bently Nevada 3300\/12","description":"\u003cp\u003e\u003cspan class=\"citation-896\"\u003eModel\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-896\"\u003eBently Nevada 3300\/12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-896\"\u003e\u003cspan\u003e \u003c\/span\u003eto zasilacz AC, który zapewnia niezawodne, regulowane zasilanie dla maksymalnie 12 monitorów i ich powiązanych przetworników w stojaku 3300\u003c\/span\u003e\u003cspan class=\"citation-896 citation-end-896\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-895\"\u003e\u003c\/span\u003eJest instalowany na najbardziej lewej pozycji (pozycja 1) stojaka\u003cspan class=\"citation-895 citation-end-895\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan class=\"citation-894\"\u003e\u003c\/span\u003eSpecyfikacje techniczne\u003cspan class=\"citation-894 citation-end-894\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch4\u003e1. Zasilanie wejściowe\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003eOpcje napięcia\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e: Wybierane przez użytkownika dla\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e95 do 125 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(maks. 1,0 A) lub\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e190 do 250 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(maks. 0,5 A), jednofazowe, 50 do 60 Hz\u003c\/span\u003e\u003cspan class=\"citation-893 citation-end-893\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-892\"\u003eMożliwość zmiany w terenie\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-892\"\u003e: Napięcie wejściowe można zmienić w terenie za pomocą przylutowanego zworka i wymieniając zewnętrzną bezpiecznik\u003c\/span\u003e\u003cspan class=\"citation-892 citation-end-892\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-891\"\u003ePrąd rozruchowy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-891\"\u003e: 26 A szczytowo lub 12 A rms przez jeden cykl\u003c\/span\u003e\u003cspan class=\"citation-891 citation-end-891\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Wyjścia\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-890\"\u003eZasilanie przetwornika\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-890\"\u003e: Dostarcza regulowane napięcie stałe wewnątrz stojaka\u003c\/span\u003e\u003cspan class=\"citation-890 citation-end-890\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003eProgramowalne napięcie\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e: Programowalne w terenie dla\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-24 Vdc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+0%, -2,5%) lub\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-18 Vdc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+1%, -2%)\u003c\/span\u003e\u003cspan class=\"citation-889 citation-end-889\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-888\"\u003eOchrona\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-888\"\u003e: Napięcia przetworników są chronione przed przeciążeniem na poszczególnych płytkach monitorów\u003c\/span\u003e\u003cspan class=\"citation-888 citation-end-888\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"citation-887\"\u003e\u003c\/span\u003e\u003cstrong\u003e3. Przekaźnik OK\u003c\/strong\u003e\u003cspan class=\"citation-887 citation-end-887\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunkcja\u003c\/strong\u003e: Zapewnia wskazanie statusu na poziomie systemu.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-886\"\u003e\u003c\/span\u003eUtrata zasilania podstawowego, awaria monitora lub awaria okablowania przetwornika spowoduje zmianę stanu przekaźnika\u003cspan class=\"citation-886 citation-end-886\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-885\"\u003eTyp\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-885\"\u003e: Przełącznik jednobiegunowy, dwupozycyjny (SPDT)\u003c\/span\u003e\u003cspan class=\"citation-885 citation-end-885\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-884\"\u003eUszczelnienie\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-884\"\u003e: Hermetycznie zamknięty\u003c\/span\u003e\u003cspan class=\"citation-884 citation-end-884\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParametry styków\u003c\/strong\u003e: 5 A przy 28 Vdc lub 120 Vac;\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-883\"\u003e\u003c\/span\u003e3 A przy 220 Vac (obciążenie rezystancyjne)\u003cspan class=\"citation-883 citation-end-883\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-882\"\u003eDziałanie\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-882\"\u003e: Zwykle zasilany\u003c\/span\u003e\u003cspan class=\"citation-882 citation-end-882\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-881\"\u003e\u003c\/span\u003e4. Parametry fizyczne i środowiskowe\u003cspan class=\"citation-881 citation-end-881\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-880\"\u003eTemperatura pracy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-880\"\u003e: 0°C do +65°C (+32°F do +150°F)\u003c\/span\u003e\u003cspan class=\"citation-880 citation-end-880\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-879\"\u003eTemperatura przechowywania\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-879\"\u003e: -40°C do +85°C (-40°F do +185°F)\u003c\/span\u003e\u003cspan class=\"citation-879 citation-end-879\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-878\"\u003eWilgotność\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-878\"\u003e: Do 95% bez kondensacji\u003c\/span\u003e\u003cspan class=\"citation-878 citation-end-878\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-877\"\u003eWaga\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-877\"\u003e: 1 kg (2,2 funta)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-876\"\u003e\u003c\/span\u003eInformacje o zamówieniu (kody sufiksów)\u003cspan class=\"citation-876 citation-end-876\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFormat zamówienia: 3300\/12-AXX-BXX-CXX\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-875\"\u003eA: Opcja napięcia wejściowego\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-875\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-875 citation-end-875\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 95-125 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 190-250 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-874\"\u003eB: Opcja modułu wejściowego zasilania (PIM)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-874\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-874 citation-end-874\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20\u003c\/strong\u003e: Standardowe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e22\u003c\/strong\u003e: Wewnętrzne bariery bezpieczeństwa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e23\u003c\/strong\u003e: Tylko zapasowe zasilanie (bez PIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-873\"\u003eC: Opcja zatwierdzenia agencji\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-873\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-873 citation-end-873\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Nie wymagane\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-872\"\u003e01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-872\"\u003e: CSA\/NRTL\/C (Klasa I, Dywizja 2)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-872 citation-end-872\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-871\"\u003e02\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-871\"\u003e: Samocertyfikacja ATEX\u003c\/span\u003e\u003cspan class=\"citation-871 citation-end-871\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eWażne uwagi dotyczące instalacji\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003eRedundancja\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e: Drugi zasilacz jest\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003enigdy nie jest wymagane\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e\u003cspan\u003e \u003c\/span\u003ew tym samym stojaku 3300\u003c\/span\u003e\u003cspan class=\"citation-870 citation-end-870\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-869\"\u003eFiltrowanie szumów\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-869\"\u003e: Model 3300\/12 jest standardowo wyposażony w filtr szumów linii\u003c\/span\u003e\u003cspan class=\"citation-869 citation-end-869\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-868\"\u003eBezpieczeństwo\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-868\"\u003e: Zaleca się podłączenie zewnętrznego sygnalizatora do zacisków przekaźnika OK, aby zapewnić operatorom powiadomienie o utracie ochrony maszyny\u003c\/span\u003e\u003cspan class=\"citation-868 citation-end-868\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666855850347,"sku":"3300\/12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-12-power-supply-module-rdqathnprlx_e7da0184-0869-4ca4-9c0f-d1e92e31bca5.jpg?v=1765449181"},{"product_id":"bently-nevada-106m1079-01-3500-15-universal-ac-power-supply-module","title":"Moduł zasilania uniwersalnego prądu przemiennego Bently Nevada 106M1079-01 3500\/15","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 106M1079-01\u003c\/strong\u003e to moduł \u003cstrong\u003eUniwersalnego zasilacza AC\u003c\/strong\u003e o połowie wysokości, zaprojektowany dla systemu ochrony maszyn serii 3500. Moduł ten służy jako podstawowe lub redundantne źródło zasilania, przetwarzając szeroki zakres wysokiego napięcia prądu przemiennego na stabilne, regulowane napięcia wewnętrzne wymagane przez inne moduły monitorujące i komunikacyjne w tej samej szafie. Musi być zainstalowany w wyznaczonych slotach po lewej stronie konstrukcji szafy 3500, gdzie może zapewniać pełne zasilanie systemu niezależnie lub współpracować z zapasowym zasilaczem bez przerywania bieżącej ochrony maszyn. Konfiguracja \u003cstrong\u003e106M1079-01\u003c\/strong\u003e gwarantuje stabilne dostarczanie energii elektrycznej dla ciągłego monitorowania drgań, położenia i prędkości w krytycznych instalacjach przemysłowych z szybkozrotującymi maszynami.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKonstrukcja modułu o połowie wysokości optymalizująca wykorzystanie lewego slotu w szafie\u003c\/li\u003e\n\u003cli\u003eObsługuje pełne zasilanie szafy z pojedynczego modułu\u003c\/li\u003e\n\u003cli\u003eArchitektura podwójnej redundancji z możliwością wymiany na gorąco, pozwalająca na wymianę bez przerywania monitorowania kanałów operacyjnych\u003c\/li\u003e\n\u003cli\u003eZintegrowany wskaźnik stanu diody LED \"SUPPLY OK\" na panelu przednim dla natychmiastowej weryfikacji technicznej\u003c\/li\u003e\n\u003cli\u003eSzeroka uniwersalna tolerancja napięcia wejściowego AC dostosowująca się bezpośrednio do zmiennych sieci elektrycznych zakładu\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundantny rozdział zasilania dla krytycznych systemów ochrony maszyn serii 3500\u003c\/li\u003e\n\u003cli\u003eStacje ciągłego monitorowania drgań turbin, sprężarek i dużych silników\u003c\/li\u003e\n\u003cli\u003ePrzemysłowe zakłady przetwórcze o wysokiej dostępności dla ropy, gazu i energetyki\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (firma Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106M1079-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniwersalny moduł zasilania AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne napięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 do 220 Vac nominalne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego (obszary bezpieczne)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 do 264 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego (obszary niebezpieczne)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 do 250 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSzczytowe napięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 do 373 Vac pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęstotliwość wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 do 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePobór prądu pełnej szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,8 A rms (maksymalny)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eElement interfejsu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED na panelu przednim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDioda LED SUPPLY OK wskazuje, gdy zasilacz działa prawidłowo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfejs PIM z tyłu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBezpośrednie połączenie z dopasowanym uniwersalnym modułem wejścia zasilania AC (PIM) za slotem zasilania\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział slotów\u003c\/strong\u003e: Upewnij się, że moduł zasilania jest włożony wyłącznie do slotów o połowie wysokości po lewej stronie szafy ochrony maszyn 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja redundancji\u003c\/strong\u003e: Przy konfiguracji podwójnego zasilania redundantnego zainstaluj moduł podstawowy w dolnym slocie, a moduł zapasowy w górnym slocie.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKompatybilność modułów\u003c\/strong\u003e: Nie próbuj łączyć uniwersalnego zasilacza AC z legacy modułami PIM wysokiego lub niskiego napięcia AC, ponieważ są całkowicie niekompatybilne.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWentylacja i środowisko\u003c\/strong\u003e: Zapewnij odpowiedni odstęp i przepływ powietrza, aby utrzymać warunki pracy w zakresie od -30°C do +65°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC\u003c\/strong\u003e: Zgodność z częścią 15 przepisów FCC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC\u003c\/strong\u003e: Dyrektywa Wspólnoty Europejskiej 2014\/30\/UE; Normy EN 61000-6-2 (odporność) i EN 61000-6-4 (emisje).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne\u003c\/strong\u003e: Dyrektywa Wspólnoty Europejskiej: Dyrektywa niskonapięciowa 2014\/35\/UE; Normy: EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS\u003c\/strong\u003e: Dyrektywa Wspólnoty Europejskiej 2011\/65\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMorski\u003c\/strong\u003e: Zasady klasyfikacji DNV GL (statki, jednostki offshore, szybkie\/lekkie jednostki); Zasady ABS dla warunków klasyfikacji Część 1, zasady statków stalowych, jednostek offshore i konstrukcji.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmerykańskie zatwierdzenia stref zagrożenia (CNRTLUS)\u003c\/strong\u003e: Klasa I, Strefa 2: AEx\/Ex nA nC ic IIC T4 Gc; Klasa I, Strefa 2: AEx\/Ex ec nC ic IIC T4 Gc; Klasa I, Podział 2, Grupy A, B, C i D; T4 @ Ta = -20°C do +65°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx\u003c\/strong\u003e: II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20°C do +65°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCo się stanie, jeśli jeden zasilacz zawiedzie w systemie z podwójnym zasilaniem?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJeśli zainstalowane są dwa zasilacze, dolny moduł jest podstawowy, a górny to zapasowy. Jeśli jeden zawiedzie, drugi automatycznie utrzymuje pełną pracę szafy bez żadnych zakłóceń systemu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł jest kompatybilny wstecz z starszymi legacy wejściami zasilania Bently Nevada?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie. Uniwersalny moduł zasilania AC i odpowiadający mu moduł wejścia zasilania (PIM) są całkowicie niekompatybilne z legacy zasilaczami AC 3500 i komponentami PIM legacy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJaki bezpiecznik należy zastosować do ochrony powiązanego interfejsu wejścia zasilania?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDopasowany uniwersalny moduł zasilania AC wykorzystuje bezpiecznik szybki o wartości 5A\/500 Vac i wymiarach fizycznych 6,3 mm x 32 mm.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666858537323,"sku":"3500\/15 106M1079-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-106m1079-01-ac-and-dc-power-supply-okimiqugwsk_3990188f-7544-4ed1-a203-6dac8b418546.jpg?v=1765449241"},{"product_id":"bently-nevada-135489-04-3500-40m-proximitor-i-o-module-with-internal-barriers","title":"Moduł wejścia\/wyjścia Bently Nevada 135489-04 3500\/40M Proximitor z barierami wewnętrznymi","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e135489-04\u003c\/strong\u003e (135489-04) to wysokowydajny moduł wejścia\/wyjścia specjalnie zaprojektowany dla systemu monitorującego Bently Nevada \u003cstrong\u003e3500\/40M\u003c\/strong\u003e Proximitor. Ten czterokanałowy interfejs łączy przetworniki polowe z szafą ochrony maszyn, oferując zintegrowane \u003cstrong\u003ebarierki wewnętrzne\u003c\/strong\u003e i \u003cstrong\u003ezakończenia wewnętrzne\u003c\/strong\u003e. Ta konfiguracja jest kluczowa dla instalacji w strefach zagrożonych, ponieważ wbudowane bariery bezpieczeństwa ograniczają energię elektryczną, zapobiegając zapłonowi w atmosferach wybuchowych.\u003c\/p\u003e\n\u003cp\u003eModuł przetwarza sygnały impulsowe i przemieszczenia z przetworników zbliżeniowych, aby monitorować istotne parametry maszyn, w tym drgania promieniowe, pozycję osiową, ekscentryczność, rozszerzalność różnicową oraz REBAM. Dostarczając ciągłą ochronę maszyn i wysokiej jakości dane dla personelu operacyjnego, \u003cstrong\u003e135489-04\u003c\/strong\u003e stanowi kluczowy element w redukcji nieplanowanych przestojów krytycznych urządzeń w energetyce, przemyśle naftowym i petrochemicznym.\u003c\/p\u003e\n\u003ch3\u003eArchitektura sprzętowa i przetwarzanie sygnału\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e moduł zaprojektowano z architekturą o wysokiej gęstości, która obsługuje do czterech sygnałów z przetworników zbliżeniowych jednocześnie. Posiada wewnętrzną izolację galwaniczną oraz elementy bezpieczeństwa zgodne z parametrami jednostkowymi CSA-NRTL\/C i ATEX\/IECEx.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramowanie kanałów\u003c\/strong\u003e: Kanały monitorujące są programowane parami, co pozwala systemowi wykonywać jednocześnie do dwóch różnych funkcji (np. kanały 1 i 2 monitorują drgania promieniowe, a kanały 3 i 4 pozycję osiową).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBariery bezpieczeństwa\u003c\/strong\u003e: Moduł zawiera obwód bariery Proximitor z określonymi parametrami mocy (PWR) i sygnału (SIG), zapewniając, że poziomy Vmax i Imax pozostają w bezpiecznych granicach dla bezpieczeństwa wewnętrznego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzetwarzanie sygnału\u003c\/strong\u003e: Sprzęt oferuje zaawansowane możliwości filtrowania, w tym filtry bezpośrednie (do 4000 Hz), filtry szczelinowe oraz filtry stałej Q do śledzenia wektorów 1X i 2X.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e135489-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeria 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Proximitor z barierami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSygnały wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 4 przetworników zbliżeniowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo 7,7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZasilanie przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do +65 st. C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJak bariera wewnętrzna wpływa na wymagania dotyczące okablowania w terenie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e zawiera wbudowane bariery bezpieczeństwa, co eliminuje potrzebę stosowania zewnętrznych barier zenera lub izolatorów galwanicznych między szafą a strefą zagrożenia. Upraszcza to układ szafy i zmniejsza całkowitą impedancję pętli.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł może być używany zarówno do drgań promieniowych, jak i do położenia osiowego?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak. Monitor 3500\/40M w połączeniu z tym modułem I\/O pozwala na konfigurowanie kanałów parami do różnych funkcji, takich jak drgania promieniowe na jednej parze i pozycja osiowa na drugiej.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie są podstawowe parametry jednostkowe dla barier wewnętrznych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDla bariery Proximitor (PWR) Vmax wynosi 26,25 V, a Imax 110,48 mA. Dla sygnału (SIG) Vmax to 13,65 V, a Imax 2,74 mA.\u003c\/p\u003e\n\u003ch3\u003e🛠️ Przewodnik instalacji i kluczowe kroki\u003c\/h3\u003e\n\u003cp\u003eModel 135489-04 to moduł I\/O z \u003cspan\u003ewewnętrznymi barierami\u003c\/span\u003e i \u003cspan\u003ewewnętrznymi zakończeniami\u003c\/span\u003e. Montuje się go z tyłu szafy 3500, bezpośrednio za \u003cspan\u003emonitor Proximitor 3500\/40M\u003c\/span\u003e. Zapewnia iskrobezpieczną (IS) izolację dla przetworników znajdujących się w strefach zagrożenia.\u003c\/p\u003e\n\u003ch4\u003e1. Instalacja sprzętu\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eTryb obejścia kanałów:\u003c\/span\u003e Przed włożeniem modułu ustaw powiązane kanały monitorujące w tryb \u003cspan\u003eobejścia\u003c\/span\u003e, aby zapobiec przypadkowym wyłączeniom maszyn.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eWyrównanie slotów:\u003c\/span\u003e Włóż moduł I\/O do pełnowysokiego slotu z tyłu szafy, który odpowiada dokładnie modułowi monitorującemu 3500\/40M z przodu.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eMontaż i zabezpieczenie:\u003c\/span\u003e Wprowadź moduł wzdłuż szyn podwozia, aż połączy się solidnie z złączami tylnej płyty. Dokładnie dokręć dwa śruby motylkowe na przednim panelu.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eUziemienie IS:\u003c\/span\u003e Szafa 3500 \u003cspan\u003emusi zawierać moduł uziemienia 3500\/04 IS\u003c\/span\u003e. Upewnij się, że palce uziemiające z tyłu modułu I\/O mają pewny kontakt z magistralą uziemienia IS szafy.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Okablowanie i separacja fizyczna\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eKolorowe zaciski:\u003c\/span\u003e Podłącz okablowanie przetworników strefy zagrożenia do zacisków \u003cspan\u003eniebieskich\u003c\/span\u003e. Podłącz sygnały wyjściowe strefy bezpiecznej do zacisków \u003cspan\u003ezielonych\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eOdległość 50 mm (2 cale):\u003c\/span\u003e Zachowaj minimalną odległość fizyczną \u003cspan\u003e50 mm (2 cale)\u003c\/span\u003e między okablowaniem strefy zagrożenia (iskrobezpiecznym) a okablowaniem strefy bezpiecznej.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eŚcieżka prowadzenia przewodów:\u003c\/span\u003e Prowadź okablowanie strefy zagrożenia w górę do górnych korytek kablowych, a okablowanie strefy bezpiecznej w dół do dolnych korytek, aby zapobiec krzyżowaniu sygnałów.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e🛒 Uwagi dotyczące zamówień\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eBrak przetworników magistralnych:\u003c\/strong\u003e Moduły I\/O z wewnętrznymi barierami \u003cspan\u003enie obsługują\u003c\/span\u003e przetworników magistralnych (wspólne linie zasilania). Każdy przetwornik musi być okablowany niezależnie.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWymagania dotyczące głębokości obudowy: \u003c\/strong\u003eModuły z wewnętrznymi barierami są głębsze niż standardowe moduły I\/O. \u003cspan\u003eNie mieszczą się w standardowych szafach o głębokości 400 mm\u003c\/span\u003e. Wymagana jest minimalna głębokość szafy \u003cspan\u003e600 mm\u003c\/span\u003e lub obudowa montowana na przepustach\/panelu.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRedukcja liczby slotów:\u003c\/strong\u003e Instalacja obowiązkowego modułu uziemienia 3500\/04 IS zajmuje jeden dedykowany slot I\/O. Zmniejsza to maksymalną liczbę dostępnych slotów monitorujących w standardowej szafie 19-calowej \u003cspan\u003ez 14 do 13\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eTylko zakończenia wewnętrzne: \u003c\/strong\u003eTen konkretny model (-04) posiada wewnętrzne zaciski śrubowe. \u003cspan\u003eNie może być używany\u003c\/span\u003e z zewnętrznymi blokami zakończeniowymi (ETB) ani z prefabrykowanymi kablami.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOgraniczenia temperaturowe: \u003c\/strong\u003eSzafy wyposażone w wewnętrzne bariery mają węższy zakres temperatur pracy od \u003cspan\u003e0°C do +65°C\u003c\/span\u003e (32°F do +150°F), w porównaniu do standardowego dolnego limitu -30°C. Zapewnij odpowiednią wentylację szafy.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863583595,"sku":"135489-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-04-i-o-module-with-internal-barriers-and-internal-terminations-pfud1qtzn2t_898c93e6-a81e-4c17-af39-a2ae95a5f4a2.jpg?v=1765449377"},{"product_id":"bently-nevada-3500-33-03-00-149992-03-low-current-16-channel-relay-output-module","title":"Moduł wyjściowy przekaźnikowy niskoprądowy 16-kanałowy Bently Nevada 3500\/33-03-00 149992-03","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003eBently Nevada 3500\/33-03-00 149992-03\u003c\/strong\u003e to pełnowymiarowy 16-kanałowy moduł wyjściowy przekaźnika zaprojektowany do zaawansowanego programowalnego głosowania bezpieczeństwa i logiki sterowania alarmem dla \u003cstrong\u003eSystemu Ochrony Maszyn Serii 3500\u003c\/strong\u003e. Jako fabrycznie skonfigurowany zespół niskoprądowy, \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e posiada specjalistyczne pozłacane styki przekaźników, zaprojektowane specjalnie, aby zapewnić maksymalną integralność styków i zapobiegać utlenianiu powierzchni w aplikacjach sygnalizacji niskoprądowej. Każde z jego szesnastu niezależnych wyjść posiada dedykowaną \u003cstrong\u003eLogikę Sterowania Alarmem\u003c\/strong\u003e, pozwalając operatorom na programowanie złożonych bramek logicznych AND\/OR wykorzystujących statusy alertu, zagrożenia lub Not-OK zbierane z dowolnego modułu monitorującego drgania, pozycję lub temperaturę w całej szafie. To połączenie sprzętu i oprogramowania służy jako wysoce niezawodny, sprzętowo głosowany most awaryjnego wyłączenia między krytycznymi obrotowymi zasobami zakładu a zewnętrznymi systemami sterowania rozproszonego (\u003cstrong\u003eDCS\u003c\/strong\u003e), programowalnymi sterownikami logicznymi (\u003cstrong\u003ePLC\u003c\/strong\u003e) lub systemami awaryjnego wyłączenia (\u003cstrong\u003eESD\u003c\/strong\u003e).\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKompletny zintegrowany 16-kanałowy zespół przekaźników bezpieczeństwa składający się z \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e kod systemu oraz \u003cstrong\u003e149992-03\u003c\/strong\u003e płyta główna procesora ze stykami złoconymi.\u003c\/li\u003e\n\u003cli\u003eWbudowane pozłacane styki zoptymalizowane do bardzo stabilnego przełączania obwodów niskonapięciowych i niskoprądowych.\u003c\/li\u003e\n\u003cli\u003eWysoce elastyczna macierz \u003cstrong\u003eLogiki Sterowania Alarmem\u003c\/strong\u003e wspierająca niestandardowe schematy głosowania oparte na wielokanałowych zmiennych alertu i zagrożenia.\u003c\/li\u003e\n\u003cli\u003eArchitektura hot-plug umożliwiająca wymianę karty na gorąco bez zakłócania pracy sąsiednich pętli ochrony maszyn online.\u003c\/li\u003e\n\u003cli\u003eIndywidualne przypisania przełączników sprzętowych na płytce drukowanej umożliwiające niezależną konfigurację Normalnie Załączony (\u003cstrong\u003eNE\u003c\/strong\u003e) lub Normalnie Wyłączony (\u003cstrong\u003eNDE\u003c\/strong\u003e) dla każdego przekaźnika.\u003c\/li\u003e\n\u003cli\u003ePrzejrzysta diagnostyka LED na przednim panelu zapewniająca wizualną ocenę stanu modułu w czasie rzeczywistym (OK), aktywności magistrali komunikacyjnej (TX\/RX) oraz stanów alarmowych poszczególnych kanałów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfejsy łączące alarmy niskoprądowe z ochroną ciężkich maszyn obrotowych do przemysłowych sterowników PLC i kontrolerów bezpieczeństwa.\u003c\/li\u003e\n\u003cli\u003eRozproszona logika głosowania i automatyczne mapowanie awaryjnego wyłączenia dla wysoko krytycznych turbin parowych, turbin gazowych i sprężarek.\u003c\/li\u003e\n\u003cli\u003eWielopunktowe sygnalizowanie awaryjnego wyłączenia w wymagających zakładach petrochemicznych, rafineriach ropy naftowej i elektrowniach.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod zamówienia \/ Numer części komponentu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKompletny zespół modułu przekaźnikowego 16-kanałowego z przekaźnikami niskoprądowymi, bez zatwierdzeń agencji.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja modułu przekaźnikowego niskoprądowego (używa modułu wyjściowego z pozłacanymi stykami).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: Brak.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eKomponent płyty głównej:\u003c\/strong\u003e Moduł główny przekaźnika 16-kanałowego niskoprądowego z pozłacanymi stykami.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKategoria parametru\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePołączone oznaczenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł przekaźnikowy 16-kanałowy (wariant niskoprądowy z pozłacanymi stykami)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 5,8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp styków przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzełącznik jednobiegunowy, dwutorowy (SPDT) \/ styki pozłacane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 V, 1 mA minimalnie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksymalne obciążenie styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V DC przy 2 A rezystancyjnie \/ 48 V DC przy 0,2 A rezystancyjnie \/ 125 V DC przy 0,1 A rezystancyjnie \/ 250 V AC przy 2 A rezystancyjnie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTryb pracy styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzełącznik na płycie wybierający Normalnie Bez Zasilania (NDE) lub Normalnie Zasilany (NE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary karty głównej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 cala x 0,96 cala x 9,52 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary karty I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 cala x 0,96 cala x 3,90 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,82 kg (1,8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,41 kg (0,9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cp\u003eOdczyty diagnostyczne na przednim panelu oraz fizyczne zakończenia z tyłu ułatwiają wyraźne śledzenie interfejsów:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIdentyfikator komponentu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis funkcjonalny \/ Przypisanie\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLampka stanu na przednim panelu; świeci ciągłym zielonym światłem, gdy wewnętrzne algorytmy oprogramowania działają prawidłowo.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLampka komunikacji na przednim panelu; szybko miga, wskazując aktywny ruch cyfrowej szyny.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda CHALRM (1 - 16)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLampki stanu kanału; niezależne diody LED świecą bezpośrednio, gdy dany kanał przekaźnika jest aktywowany.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStyki tylnego bloku zaciskowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiny połączeniowe tylnej szyny I\/O grupujące linie Wspólne (COM), Normalnie Otwarte (NO) i Normalnie Zamknięte (NC).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrzełączniki trybu przekaźnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFizyczne wielopozycyjne przełączniki dwutorowe na płycie przypisujące indywidualne stany kanałów do NDE lub NE.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePozycjonowanie w szafie:\u003c\/strong\u003e Wsuń kompletny zespół modułu \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e do dowolnego dostępnego slotu pełnej wysokości, znajdującego się ściśle po prawej stronie modułu Transient Data Interface (\u003cstrong\u003eTDI\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUstawienie tylne:\u003c\/strong\u003e Zamocuj odpowiedni 16-kanałowy wewnętrzny moduł zakończenia wejścia\/wyjścia (np. 149986-01) w pasującym tylnym slocie bezpośrednio za główną kartą.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja przełączników na płycie:\u003c\/strong\u003e Dostosuj wewnętrzne przełączniki fizyczne, aby określić wymagany stan Normalnie Załączony lub Normalnie Wyłączony dla każdego kanału przed wsunięciem płyty do aktywnego gniazda.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeryfikacja napięcia pętli:\u003c\/strong\u003e Potwierdź, że pętle instrumentów po stronie odbiorczej ściśle spełniają ograniczenia niskiego napięcia i niskiego prądu; wprowadzenie ciężkich obciążeń indukcyjnych lub wysokoprądowych zniszczy złocone powierzchnie styków.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja logiki:\u003c\/strong\u003e Otwórz oprogramowanie systemowe szafy, aby zmapować i załadować zamierzoną macierz głosowania AND\/OR do nieulotnej pamięci modułu przed testowaniem systemu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e Dyrektywa Wspólnoty Europejskiej 2014\/30\/UE (dyrektywa EMC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy EMC:\u003c\/strong\u003e EN 61000-6-2 (odporność przemysłowa), EN 61000-6-4 (emisje przemysłowe).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Dyrektywa niskonapięciowa 2014\/35\/UE, norma EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa RoHS:\u003c\/strong\u003e Zgodność europejska 2011\/65\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty do stref zagrożonych:\u003c\/strong\u003e cNRTLus Klasa I, Strefa 2: AEx\/Ex nA nC ic IIC T4 Gc \/ Klasa I, Podział 2, Grupy A, B, C i D (T4 @ Ta = -20°C do +65°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty ATEX\/IECEx:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest funkcjonalna zależność między kodem 3500\/33-03-00 a numerem części 149992-03?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e reprezentuje kompletny fabryczny numer modelu zamówienia określający 16-kanałowy system przekaźnikowy skonfigurowany do zastosowań niskoprądowych, podczas gdy \u003cstrong\u003e149992-03\u003c\/strong\u003e dokładny numer części producenta jest nadrukowany na fizycznej płycie głównego procesora niskoprądowego zawartej w tej konkretnej kombinacji.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDlaczego złocenie jest istotne dla styków w tym module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZłocenie jest kluczowe dla obwodów niskoprądowych (do 1 V, 1 mA), ponieważ standardowe srebrne styki z czasem tworzą warstwy utleniania na powierzchni przy niskich obciążeniach elektrycznych, podczas gdy złoto jest odporne na matowienie, zapewniając czystą ścieżkę połączenia.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy mogę wykonać wymianę na gorąco tego modułu podczas aktywnego monitorowania maszyn?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, jednostka posiada w pełni wymienną na gorąco architekturę, co pozwala zespołom serwisowym na wyjęcie lub włożenie karty do gniazda bez odłączania zasilania lub powodowania spadków sygnału na sąsiednich kanałach monitora.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy pojedyncze zamówienie tego produktu obejmuje zarówno przedni procesor, jak i tylną płytę terminalową?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKupując jako kompletny zapasowy lub nadmiarowy zespół zgodny z tymi specyfikacjami fabrycznymi, zazwyczaj oznacza to główną kartę; upewnij się, czy panel Twojego systemu wymaga również pasującego tylnego wewnętrznego bloku zakończeniowego 149986-01.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865549675,"sku":"3500\/33-03-00 149992-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-03-00-149992-03-spare-16-channel-low-current-relay-output-module-mybdn1u1yaf_20bc0d4c-1b25-4073-ac9e-559a8b4766c0.jpg?v=1765449433"},{"product_id":"bently-nevada-135489-01-3500-42m-i-o-module-with-internal-barriers","title":"Moduł Wejścia\/Wyjścia Bently Nevada 135489-01 3500\/42M z Wbudowanymi Barierami","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e135489-01\u003c\/strong\u003e to 4-kanałowy moduł Wejścia\/Wyjścia (I\/O) zaprojektowany do współpracy z \u003cstrong\u003e3500\/42M\u003c\/strong\u003e Proximitor Seismic Monitor w ramach systemu ochrony maszyn \u003cstrong\u003eserii 3500\u003c\/strong\u003e. Ten konkretny wariant sprzętowy wyposażony jest w \u003cstrong\u003ewewnętrzne bariery\u003c\/strong\u003e oraz \u003cstrong\u003ewewnętrzne zakończenia\u003c\/strong\u003e, zapewniając kompaktowy i bezpieczny interfejs dla przetworników umieszczonych w niebezpiecznych środowiskach przemysłowych.\u003c\/p\u003e\n\u003cp\u003eModuł przetwarza sygnały dla \u003cstrong\u003e4 x Prox\/Accel\u003c\/strong\u003e (przetworników zbliżeniowych lub akcelerometrów) na kanałach od 1 do 4. Dzięki integracji wewnętrznych barier bezpieczeństwa, \u003cstrong\u003e135489-01\u003c\/strong\u003e ogranicza energię elektryczną wysyłaną do czujników polowych, zapobiegając potencjalnemu zapłonowi w atmosferach wybuchowych, jednocześnie eliminując potrzebę stosowania zewnętrznego sprzętu barierowego. Jest to kluczowy element do monitorowania drgań, położenia i aktywności sejsmicznej w przypadku cennych obrotowych urządzeń, takich jak turbiny, sprężarki i silniki.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e135489-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi (zakończenia wewnętrzne)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeria 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKompatybilny moduł główny\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e3500\/42M\u003c\/strong\u003e Monitor sejsmiczny Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x Prox\/Accel (kanały 1-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C do +65°C (32°F do +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cp\u003ePodczas zamawiania części zamiennych do \u003cstrong\u003e3500\/42M\u003c\/strong\u003e system, zweryfikuj konkretne opcje zamówienia, aby zapewnić zgodność modułu I\/O z wymaganiami zakończeń i barier szafy.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e: \u003cstrong\u003e135489-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpcja zamówienia AA\u003c\/strong\u003e: 04\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpis I\/O\u003c\/strong\u003e: Moduł I\/O z barierami wewnętrznymi, zakończeniami wewnętrznymi, 4 x Prox\/Accel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUwagi inżynieryjne i instalacyjne\u003c\/h3\u003e\n\u003ch3\u003eOkablowanie polowe i zakończenia wewnętrzne\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBezpośrednie połączenie\u003c\/strong\u003e: Moduł \u003cstrong\u003e135489-01\u003c\/strong\u003e wykorzystuje wewnętrzne zakończenia, co oznacza, że okablowanie z przetworników jest podłączane bezpośrednio do zacisków śrubowych na obudowie modułu, znajdujących się z tyłu szafy 3500.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBezpieczeństwo w strefach zagrożonych\u003c\/strong\u003e: Bariery wewnętrzne są zaprojektowane tak, aby zachować integralność obwodów iskrobezpiecznych (IS). Upewnij się, że zachowana jest segregacja okablowania między okablowaniem IS a okablowaniem nie-IS w szafie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eObsługa przetworników\u003c\/strong\u003e: Ten moduł jest specjalnie przeznaczony dla wejść \u003cstrong\u003eProximity\u003c\/strong\u003e i \u003cstrong\u003eAccelerometer\u003c\/strong\u003e. Potwierdź, że typ przetwornika w terenie odpowiada konfiguracji kanałów (Kanały 1-4), aby uniknąć błędów przetwarzania sygnału.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKroki instalacji\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParowanie z monitorem\u003c\/strong\u003e: Ten moduł I\/O musi być zainstalowany w tylnej zatoce szafy 3500 odpowiadającej przedniemu modułowi monitora \u003cstrong\u003e3500\/42M\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpecyfikacje momentu dokręcania\u003c\/strong\u003e: Upewnij się, że wszystkie śruby zaciskowe są prawidłowo dokręcone, aby utrzymać stabilne połączenie elektryczne, szczególnie w środowiskach narażonych na wibracje przemysłowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZgodność środowiskowa\u003c\/strong\u003e: Dla modułów używanych z barierami wewnętrznymi temperatura pracy musi być utrzymywana w zakresie od \u003cstrong\u003e0°C do +65°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł I\/O może być używany z przetwornikami Velomitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł \u003cstrong\u003e135489-01\u003c\/strong\u003e jest przeznaczony dla \u003cstrong\u003e4 x Prox\/Accel\u003c\/strong\u003e. Użycie z innymi typami przetworników może wymagać innej wersji modułu I\/O lub specyficznych ustawień konfiguracyjnych w monitorze \u003cstrong\u003e3500\/42M\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJaka jest zaleta wersji „Internal Barrier”?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIntegruje bariery bezpieczeństwa bezpośrednio w module I\/O, zmniejszając wymaganą przestrzeń fizyczną w szafie i upraszczając architekturę okablowania dla zastosowań w strefach zagrożonych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł jest wymienny na gorąco?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChociaż system 3500 obsługuje wymianę na gorąco, standardową praktyką inżynierską jest ominięcie wszelkich powiązanych wyłączeń maszyn przed wymianą modułu I\/O, aby zapobiec niezamierzonym zatrzymaniom.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869055851,"sku":"135489-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-01-i-o-module-4-channel-internal-barrier-akragbb2a4i_c5513e8d-df36-47f1-b473-bf9c4c7b9969.jpg?v=1765449560"},{"product_id":"honeywell-experion-pks-fta-t-20-digital-output-relay-field-termination-assembly","title":"Honeywell Experion PKS FTA-T-20 Digital Output Relay Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Field Termination Assembly (FTA) within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager (SMS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystems. It serves as the physical and electrical interface between the system's digital output modules and the external field equipment.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-load or isolated switching requirements, the FTA-T-20 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 channels of relay-contact outputs\u003c\/strong\u003e. Each channel offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNO (Normally Open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNC (Normally Closed)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtacts, allowing for flexible fail-safe configurations. By utilizing interposing relays on the FTA, the system protects the sensitive controller electronics from field-side electrical surges and allows the switching of higher voltages and currents (up to 250 Vac or 110 Vdc) than a standard electronic output could handle.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FTA-T-20 is engineered for seamless integration into Honeywell safety and control racks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 independent relay channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSPDT (Single Pole Double Throw) configuration, providing both NO and NC terminals for every channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects to the controller I\/O module via a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem interconnection cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor direct connection of field cables, supporting a variety of wire gauges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard DIN-rail mounting for installation in I\/O cabinets or marshalling panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNFS (Non-Fail Safe) Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically used in applications where the safety logic is managed by the controller, and the relay acts as the final switching element.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Relay Contact)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Vac \/ 110 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNO \/ NC (Change-over)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterconnection Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIC-C-07\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminals (T-Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10209\/2\/1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of using an FTA-T (Screw Terminal) over an FTA-E (ELCO)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion is designed for direct field wiring where the cables are terminated individually at the assembly. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ELCO) version is typically used for \"marshalling-to-marshalling\" connections using pre-fabricated multi-core cables. The FTA-T-20 is ideal for cabinets where field sensors\/actuators are wired directly to the I\/O rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC loads on the same FTA-T-20?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the relay contacts are rated for both 250 Vac and 110 Vdc, it is standard engineering practice to keep load types consistent across an FTA to prevent noise and to simplify maintenance. However, since the 8 channels are galvanically isolated from each other, they can technically switch different voltage sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I replace a faulty relay on this FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDepending on the specific hardware revision, the relays on the FTA-T-20 are often socket-mounted. This allows for \"hot-maintenance\" where an individual relay can be replaced without replacing the entire termination assembly or disturbing the wiring of the other 7 channels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that wire ferrules are used when connecting to the screw terminals. This prevents wire fraying and ensures a gas-tight connection, which is critical in corrosive industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable should be routed away from high-power AC lines to prevent induced noise, even though the relay outputs are relatively robust.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor highly inductive loads (such as large solenoid valves or motor starters), it is recommended to install external RC snubbers (for AC) or flyback diodes (for DC) to extend the life of the FTA relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFusing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways ensure that field-side circuits are properly fused. The FTA-T-20 provides the switching logic, but the current-limiting protection should be handled by external terminal fuses or circuit breakers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667743338859,"sku":"FTA-T-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-20-fta-output-module-qqfm5mreu3l_e04138f4-fd7c-4a5d-9cc3-0b76caa2f4a1.jpg?v=1765501439"},{"product_id":"bently-nevada-3500-15-05-03-00-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-05-03-00 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojketowany, aby zapewnić wysoce niezawodne i spójne rozprowadzanie energii, \u003cstrong\u003eBently Nevada 3500\/15-05-03-00\u003c\/strong\u003e jest kluczowym elementem systemu ochrony maszyn serii 3500. Ten moduł zasilania znajduje się w lewych gniazdach szafy 3500, przekształcając zasilanie wejściowe na precyzyjne napięcia stałe wymagane przez moduły monitorujące, komunikacyjne i keyphasor systemu.\u003c\/p\u003e\n\n\u003cp\u003eKonfiguracja tego konkretnego modelu obejmuje układ dwugniazdowy zaprojektowany w celu zwiększenia niezawodności systemu poprzez opcjonalną redundancję. Górne gniazdo jest przeznaczone do uniwersalnego napięcia AC (85 do 264 Vac rms), natomiast dolne gniazdo obsługuje wejścia wysokiego napięcia DC (88 do 140 Vdc). Ta wszechstronna kombinacja pozwala systemowi pozostać w pełni operacyjnym podczas standardowych wahań napięcia lub przerw w głównym zasilaniu, chroniąc krytyczne zasoby maszyn przemysłowych przed nieoczekiwanymi przestojami monitoringu.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancja z podwójnym wejściem:\u003c\/strong\u003e Umożliwia jednoczesny montaż podstawowego i zapasowego zasilacza w tej samej szafie, zapobiegając pojedynczym punktom awarii.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSzerokie tolerancje wejściowe:\u003c\/strong\u003e Obsługuje uniwersalne wejścia AC w górnym gnieździe oraz wejścia wysokiego napięcia DC w dolnym gnieździe.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZintegrowana diagnostyka:\u003c\/strong\u003e Ciągłe monitorowanie napięć wyjściowych zapewnia natychmiastowe wykrycie degradacji zasilania lub awarii modułu.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWytrzymała konstrukcja:\u003c\/strong\u003e Zaprojektowany, aby wytrzymać surowe warunki przemysłowe, działając niezawodnie w szerokim zakresie temperatur.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSystemy monitorowania drgań turbin parowych i gazowych.\u003c\/li\u003e\n  \u003cli\u003eOchrona maszyn w przemyśle petrochemicznym oraz naftowym i gazowym.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie ciężkich urządzeń obrotowych w elektrowniach.\u003c\/li\u003e\n  \u003cli\u003eZakłady uzdatniania wody i zakłady przemysłowe wykorzystujące architekturę systemu 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer katalogowy\/model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3500\/15-05-03-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSystem ochrony maszyn serii 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp zasilacza w górnym gnieździe\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUniwersalne napięcie AC (85 do 264 Vac rms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp zasilacza w dolnym gnieździe\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWysokie napięcie DC (88 do 140 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrak (00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres temperatur pracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres temperatur przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOdporność na wilgotność\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95% bez kondensacji\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymiary modułu (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12,07 cm x 5,08 cm x 25,15 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWaga netto\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,39 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMontaż w obudowie:\u003c\/strong\u003e Montować wyłącznie w dedykowanych gniazdach zasilaczy po lewej stronie szafy 3500.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKonfiguracja redundancji:\u003c\/strong\u003e Przy stosowaniu konfiguracji redundantnych zasilaczy, upewnić się, że oba wejścia pochodzą z oddzielnych obwodów zasilających, aby osiągnąć maksymalną niezawodność.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWentylacja:\u003c\/strong\u003e Nie blokować otworów wentylacyjnych na przedniej części modułu ani obudowy szafy, aby zapewnić naturalne chłodzenie konwekcyjne.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUziemienie:\u003c\/strong\u003e Przed podłączeniem zasilania upewnić się, że rama szafy jest połączona z niskoomową ścieżką uziemienia.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668277817707,"sku":"3500\/15-05-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-05-03-00-dxrvkryjouk_43a95652-b35c-4f6e-a9f7-4beda1660cc1.jpg?v=1765520309"},{"product_id":"bently-nevada-3500-15-02-02-00-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-02-02-00 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZapewniając stabilne, regulowane zasilanie prądem stałym dla całej szyny i zainstalowanych kart monitorujących, \u003cstrong\u003eBently Nevada 3500\/15-02-02-00\u003c\/strong\u003e jest niezbędnym modułem przetwornika zasilania wysokiego napięcia AC na DC zaprojektowanym dla \u003cstrong\u003eSystemu ochrony maszyn 3500\u003c\/strong\u003e. Jednostka zajmuje jedno lub dwa dedykowane gniazda na najbardziej lewej pozycji szafy, przyjmując wejścia wysokiego napięcia AC do generowania wewnętrznych napięć roboczych wymaganych do ciągłej diagnostyki maszyn i wykrywania usterek. Działając jako konfiguracja redundantna dwugniazdowa, \u003cstrong\u003e3500\/15-02-02-00\u003c\/strong\u003e obsługuje jednoczesne wejścia wysokiego napięcia AC na obu gniazdach (górnym i dolnym), chroniąc krytyczne pętle monitorujące turbiny i sprężarki przed awariami źródła zasilania.  \u003c\/p\u003e\n\n\u003ch3\u003eCechy  \u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancja dwugniazdowa:\u003c\/strong\u003e Może być skonfigurowany jako para redundantna (gniazda górne i dolne), aby zapobiec przestojom systemu podczas utraty głównego źródła zasilania.  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKompatybilność z wysokim napięciem AC:\u003c\/strong\u003e Oba gniazda zaprojektowane do napięć sieciowych od 175 do 264 Vac rms, dostosowane do przemysłowych sieci zasilających.  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostyka wewnętrzna:\u003c\/strong\u003e Ciągłe monitorowanie poziomów napięcia wyjściowego i stanu systemu, generowanie alertów przez szynę tylną szafy 3500 w przypadku przekroczenia parametrów awarii.  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWymiana na gorąco:\u003c\/strong\u003e Pojedyncze zasilacze można wymieniać bez przerywania funkcji ochronnych aktywnych modułów monitorujących w konfiguracji redundantnej szafy.  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSolidna kompatybilność elektromagnetyczna:\u003c\/strong\u003e Zaprojektowany, by wytrzymać trudne warunki elektromagnetyczne typowe dla ciężkich zakładów petrochemicznych, energetycznych i przetwórczych.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania  \u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSzafy monitorujące turbiny do wytwarzania energii.  \u003c\/li\u003e\n  \u003cli\u003eSystemy ochrony sprężarek gazowych w petrochemii oraz przemyśle naftowym i gazowym.  \u003c\/li\u003e\n  \u003cli\u003ePlatformy ciężkich maszyn obrotowych wykorzystujące architekturę systemu Bently Nevada 3500.  \u003c\/li\u003e\n  \u003cli\u003eDiagnostyka drgań dużych silników przemysłowych i pomp.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTabela specyfikacji technicznych  \u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eParametr specyfikacji  \u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eWartość \/ Szczegół  \u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProducent  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (Baker Hughes)  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOznaczenie modelu  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3500\/15-02-02-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTyp serii  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSystem ochrony maszyn 3500  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZasilacz na górnej pozycji  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWysokie napięcie AC (175 do 264 Vac rms)  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZasilacz na dolnej pozycji  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWysokie napięcie AC (175 do 264 Vac rms)  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZakres częstotliwości wejściowej  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eZakres częstotliwości wejściowej 47 do 63 Hz  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZatwierdzenia agencji  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e00 (Brak wybranych zatwierdzeń agencji)  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTemperatura pracy  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-30 do +65 stopni Celsjusza  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga netto modułu  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1,39 kg  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3,00 kg  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKraj pochodzenia  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStany Zjednoczone (Wyprodukowano w USA)  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWymiary opakowania (obliczone)  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e35,5 cm x 25,4 cm x 15,2 cm  \u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003ePołączenia i interfejsy  \u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZasilacz opiera się na module wejściowym zasilania (PIM) zamontowanym z tyłu szafy 3500, bezpośrednio za głównym modułem zasilania. Połączenia elektryczne dla linii AC muszą być solidnie zakończone na śrubowych zaciskach PIM:  \u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eZacisk PIM  \u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eFunkcja połączenia  \u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eZalecane specyfikacje przewodów  \u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eL (Faza)  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGłówny przewód fazowy dla zasilania 175-264 Vac  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePrzewód miedziany linka 14 AWG do 18 AWG  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eN (Neutralny)  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eŚcieżka powrotna neutralna  \u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePrzewód miedziany linka 14 AWG do 18 AWG  \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUziemienie (PE)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUziemienie ochronne (krytyczne dla bezpieczeństwa)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMinimalny przekrój 12 AWG, zielono-żółta izolacja\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpiryczne spostrzeżenia inżynierskie\u003c\/h3\u003e\n\u003ch4\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eStarsza \u003cstrong\u003e3500\/15-02-02-00\u003c\/strong\u003e konfiguracja posiada mapowanie 02-02-00 do wysokiego napięcia AC dla obu aktywnych slotów. Ta starsza konfiguracja została zastąpiona przez \u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e uniwersalny model zasilacza AC\/DC. Szafy łączące starsze monitory 3500 z nowszymi modułami mogą z powodzeniem korzystać z tego zasilacza; jednak przy aktualizacji z konfiguracji -02-02-00 do -05-05-00 należy upewnić się, że tylne moduły zasilania (PIM) są zaktualizowane zgodnie z uniwersalną architekturą zasilania, aby uniknąć niezgodności sprzętowych.\u003c\/p\u003e\n\n\u003ch4\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePrzy pełnym obciążeniu szafy 3500 (obejmującym podwójne zasilacze, interfejsy danych przejściowych i 14 w pełni obciążonych kart monitorujących) wewnętrzne temperatury zasilacza mogą być podwyższone. Jeśli szafa jest zamknięta w obudowie o klasie IP65 bez wentylacji, zapewnij odpowiedni margines rozpraszania ciepła. Przy konfiguracji z podwójnymi zasilaczami podłącz górny i dolny zasilacz do oddzielnych, niezależnych źródeł UPS, aby zapobiec wyłączeniu całego systemu ochrony maszyn przez pojedynczy wyłącznik nadprądowy.\u003c\/p\u003e\n\n\u003ch4\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eNigdy nie uruchamiaj zasilacza szafy 3500\/15 bez solidnego, niskooporowego uziemienia połączonego bezpośrednio z zaciskiem uziemienia PIM do głównej szyny uziemiającej szafy. Pływające punkty neutralne lub połączenia uziemienia o wysokiej rezystancji mogą wprowadzać szumy AC bezpośrednio na płytę tylnią, co może indukować zakłócenia na czułych wejściach czujników zbliżeniowych 3-przewodowych (takich jak seria 3300 XL), co może skutkować fałszywymi impulsami drgań lub wyzwoleniami instrumentów.\u003c\/p\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e Na zaciskach tylnego modułu zasilania (PIM) występują niebezpieczne wysokie napięcia (do 264 Vac). Upewnij się, że wszystkie wyłączniki nadprądowe w górze są zablokowane i oznakowane, a także zweryfikuj zerowe napięcie na wszystkich zaciskach linii za pomocą zatwierdzonego, skalibrowanego multimetru cyfrowego przed rozpoczęciem jakichkolwiek prac przy podłączaniu przewodów.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; line-height: 24px; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWsuń główną obudowę modułu zasilania 3500\/15-02-02-00 w wyznaczone najbardziej lewe sloty z przodu szafy 3500. Upewnij się, że prowadnice idealnie się pokrywają i mocno dokręć dwa śruby mocujące na panelu przednim za pomocą standardowego śrubokręta płaskiego.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; line-height: 24px; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eZamontuj odpowiedni moduł zasilania (PIM) bezpośrednio w slocie tylnej płyty za modułem zasilania. Zamocuj go na miejscu za pomocą odpowiednich elementów montażowych.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; line-height: 24px; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePodłącz przewód ochronny uziemienia (PE) bezpośrednio z głównej listwy uziemiającej szafy do zacisku uziemienia na module zasilania (PIM) używając miedzianego przewodu o minimalnym przekroju 12 AWG.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; line-height: 24px; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePoprowadź i podłącz przewody zasilające L (L) i Neutralny (N) (175 do 264 Vac) do wyznaczonych zacisków terminali. Sprawdź moment dokręcenia wszystkich połączeń, zabezpiecz osłonę terminala i ponownie włącz obwód zasilania.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668277850475,"sku":"3500\/15-02-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-02-02-00-ips1ez3exma_79abfb63-32a3-4639-8565-460f70b95c64.jpg?v=1765520310"},{"product_id":"bently-nevada-3500-32-01-cn-3500-series-4-channel-relay-module","title":"Moduł przekaźnikowy Bently Nevada 3500\/32-01-CN serii 3500, 4-kanałowy","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAby sterować zewnętrznymi pętlami sterowania maszyn i wykonywać krytyczne wyłączenia ochronne, \u003cstrong\u003eBently Nevada 3500\/32-01-CN\u003c\/strong\u003e integruje cztery w pełni programowalne wyjścia przekaźnikowe w szafie ochrony maszyn serii 3500. Ten moduł pełnowysokościowy przyjmuje logikę wejściową z innych monitorów w szafie, aby kontrolować niezależne przekaźniki SPDT. Wysoce konfigurowalny do krytycznego blokowania bezpieczeństwa, moduł zapewnia niezawodne zmiany stanu styków na podstawie statusu alarmu i zdefiniowanej przez użytkownika logiki głosowania zaprojektowanej w oprogramowaniu konfiguracyjnym 3500 Rack.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKluczowe cechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eCztery niezależne, programowalne kanały przekaźnikowe SPDT.\u003c\/li\u003e\n  \u003cli\u003eKompatybilny ze standardowymi płytami tylnego panelu i strukturami slotów serii 3500.\u003c\/li\u003e\n  \u003cli\u003eObsługuje konfiguracje „Normalnie Zasilany” (NE) i „Normalnie Odłączony” (NDE).\u003c\/li\u003e\n  \u003cli\u003eRozbudowana logika głosowania, umożliwiająca logiczne łączenie statusów Alarm i Niebezpieczeństwo z wielu kanałów monitorujących.\u003c\/li\u003e\n  \u003cli\u003eWyposażony w wbudowany monitoring stanu, zapewniający prawidłowe działanie układu sterowania przekaźnikiem.\u003c\/li\u003e\n  \u003cli\u003eOpcja oznaczona CN wskazująca zgodność z wymaganiami zatwierdzeń specyficznych dla kraju.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eWykonawcze systemy awaryjnego wyłączania maszyn dla turbin parowych, turbin gazowych i sprężarek.\u003c\/li\u003e\n  \u003cli\u003eIntegracja z systemami sterowania rozproszonego (DCS) i programowalnymi sterownikami logicznymi (PLC) do twardo okablowanego sygnalizowania alarmów.\u003c\/li\u003e\n  \u003cli\u003eAktywacja lokalnych alarmów w strefach zagrożenia, syren, świateł ostrzegawczych i wskaźników pomocniczych.\u003c\/li\u003e\n  \u003cli\u003eBlokowanie krytycznych pętli sterowania procesem na podstawie fizycznych granic drgań maszyn.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; border-right: 1px solid #2d3748;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left;\"\u003eWartość \/ Specyfikacja\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eNumer modelu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500\/32-01-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eTyp modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModuł wyjściowy przekaźnika 4-kanałowy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eLiczba kanałów\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4 przekaźniki SPDT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eParametry styków przekaźnika (rezystancyjne)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5 A przy 120 Vac \/ 240 Vac (maks.); 5 A przy 30 V DC (maks.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eMinimalne obciążenie styków\u003c\/td\u003e\n        \u003ctd style=\"padding: 100mA @ 5 Vdc;\"\u003e100 mA przy 5 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eOpcja zatwierdzeń agencji\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCN (Krajowe zatwierdzenia)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eMiejsce montażu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDowolny slot pełnowysokościowy z wyjątkiem slotów zasilacza i modułu interfejsu szafy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUSA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2,0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; border-right: 1px solid #2d3748;\"\u003eOznaczenie zacisku\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left;\"\u003ePrzypisanie funkcjonalne\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eNO (Normalnie Otwarty)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eZamyka połączenie z biegunem wspólnym, gdy cewka przekaźnika jest zasilana.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eNC (Normalnie Zamknięty)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOtwiera połączenie z biegunem wspólnym, gdy cewka przekaźnika jest zasilana.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #2d3748; font-weight: bold;\"\u003eCOM (Wspólny)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWspólny biegun odniesienia dla obwodu styków SPDT odpowiedniego kanału.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpiryczne spostrzeżenia inżynierskie\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternatywne modele i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eChociaż system 3500 obsługuje również 16-kanałowy moduł przekaźnikowy (3500\/33), 4-kanałowy 3500\/32 zapewnia solidne wyjścia SPDT Form-C, które są zazwyczaj preferowane do bezpośredniego aktywowania elektromagnesów wyzwalających. Upewnij się, że wersja oprogramowania 3500\/32 jest kompatybilna z wersją oprogramowania modułu interfejsu szafy (RIM) przed próbą zmiany przydziału slotów.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePrzy przełączaniu silnie indukcyjnych obciążeń prądu przemiennego (takich jak ciężkie zawory elektromagnetyczne lub większe rozruszniki silników) kluczowe jest zainstalowanie zewnętrznych tłumików łuku (RC snubberów) na stykach, aby zapobiec erozji styków i przedwczesnemu zgrzewaniu. Praca blisko limitu 5 A bez tłumienia może skrócić żywotność przekaźników i prowadzić do niebezpiecznych stanów „nieotwarcia”.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZawsze poprawnie skonfiguruj funkcję „OK Relay” w panelu konfiguracyjnym. W normalnych warunkach pracy zalecamy stosowanie pętli bezpieczeństwa w trybie Normalnie Zasilanym (NE) – odłączenie zasilania powoduje wyzwolenie. Zapewnia to, że całkowita utrata zasilania sterowania instrumentem automatycznie uruchamia bezpieczny stan pętli maszyny.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e Na zaciskach styków przekaźnika mogą występować niebezpieczne napięcia. Odłącz i zablokuj wszystkie zewnętrzne źródła zasilania styków przekaźnika przed serwisowaniem, demontażem lub wymianą modułu. Nieodłączenie zasilania zewnętrznego może spowodować poważny porażenie prądem, uszkodzenie komponentów lub przypadkowe wyłączenie maszyny.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWyłącz system szafy 3500, jeśli procedury bezpieczeństwa zakładu nie zezwalają na wymianę na gorąco. (System 3500 obsługuje wymianę na gorąco w określonych, ograniczonych warunkach środowiskowych).\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWłóż główny moduł 3500\/32-01-CN do przedniej części szafy, wsuwając go po prowadnicach aż do pewnego osadzenia w złączu tylnej płyty. Dokładnie dokręć dwie śruby mocujące na przednim panelu.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eZamontuj odpowiadający 4-kanałowy moduł przekaźnikowy I\/O z tyłu szafy, bezpośrednio za przednim slotem. Zamocuj go za pomocą śrub panelu obudowy.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePodłącz przewody pętli alarmowej do tylnego bloku zaciskowego, używając odpowiednich tulejek końcowych przewodów, aby zapewnić integralność mechaniczną i zapobiec zwarciom między sąsiednimi zaciskami styków.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668285419883,"sku":"3500\/32-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-32-01-CN-20ebolhvkac_5fb76d26-62ea-4888-a313-7aae204a21de.jpg?v=1765520341"},{"product_id":"bently-nevada-3500-15-04-04-cn-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-04-04-CN serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAby zapewnić ciągły, nieprzerwany monitoring w krytycznym systemie ochrony maszyn 3500, Bently Nevada 3500\/15-04-04-CN dostarcza redundantne, wysoce stabilne zasilanie do wszystkich modułów zamontowanych w szafie. Ten moduł o połowie wysokości jest skonfigurowany z podwójnymi wejściami niskiego napięcia DC, aby przyjmować zasilanie z niezależnych źródeł, minimalizując ryzyko awarii pojedynczego punktu w systemach monitoringu o wysokiej dostępności. Dzięki wykorzystaniu filtracji wysokoczęstotliwościowej i precyzyjnej regulacji napięcia chroni wrażliwe karty pomiarowe przed zewnętrznymi przepięciami i spadkami napięcia typowymi dla zakładów przemysłowych.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eKluczowe cechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePodwójne wejście niskiego napięcia DC:\u003c\/strong\u003e Skonfigurowane z kodem opcji 04 dla obu gniazd, górnego i dolnego, akceptujące napięcia wejściowe od 20 do 30 V DC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWsparcie redundancji:\u003c\/strong\u003e Umożliwia instalację dwóch zasilaczy w tej samej szafie 3500, zapewniając ciągłość działania w przypadku awarii pojedynczego zasilacza.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostyka wewnętrzna:\u003c\/strong\u003e Ciągłe monitorowanie poziomów wyjściowych i komunikacja stanu zdrowia szyny z modułem interfejsu szafy (RIM).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAktywna ochrona przeciwprzepięciowa:\u003c\/strong\u003e Wbudowana ochrona przed przepięciami (TVSS) zapobiega uszkodzeniom komponentów w wyniku anomalii sieci zasilającej.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegionalne zatwierdzenia CN:\u003c\/strong\u003e Certyfikowany dla określonych wymogów regionalnych, ułatwiający prostą instalację w kontrolowanych strefach przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWytwarzanie energii:\u003c\/strong\u003e Zapewnia wysoką niezawodność ochrony maszyn dla turbin parowych, gazowych i wodnych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrzetwórstwo ropy i gazu:\u003c\/strong\u003e Zapewnia zasilanie systemów ochrony w zakładach petrochemicznych, na platformach morskich i w pomieszczeniach kontrolnych rafinerii.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCiężki przemysł:\u003c\/strong\u003e Chroni duże sprężarki powietrza, pompy chłodzące o dużej mocy oraz wentylatory przemysłowe.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUzdatnianie wody:\u003c\/strong\u003e Zasilanie systemów monitorujących w miejskich stacjach pomp i zakładach oczyszczania ścieków o dużej wydajności.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; min-width: 500px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eWartość \/ Specyfikacja\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNumer części\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3500\/15-04-04-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSeria\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTyp modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eModuł zasilacza o połowie wysokości\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTyp zasilacza (gniazdo górne)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e04 = Niskie napięcie DC (20 do 30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTyp zasilacza (gniazdo dolne)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e04 = Niskie napięcie DC (20 do 30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eZakres napięcia wejściowego znamionowego\u003c\/td\u003e\n        \u003ctd style=\"padding: 20 to 30 Vdc;\"\u003e20 do 30 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOpcja zatwierdzenia agencji\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCN = Krajowe regionalne zatwierdzenia\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStany Zjednoczone (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWaga netto modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1,39 kg (3,06 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3,00 kg (6,61 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWymiary opakowania (obliczone)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e32,0 cm x 15,0 cm x 21,0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eEmpiryczne spostrzeżenia inżynierskie\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eModel 3500\/15-04-04-CN jest zaprojektowany specjalnie do integracji ze standardową obudową serii 3500. Nie można go łączyć z modułami wysokiego napięcia AC na tym samym układzie zacisków wejściowych. Upewnij się, że zworki tylnej płyty są zweryfikowane pod kątem dystrybucji DC podczas migracji ze starszych systemów 3500\/15 opartych na AC.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eW zamkniętych panelach polowych, gdzie temperatura otoczenia przekracza 50°C, stosowanie redundantnych zasilaczy generuje lokalne gorące punkty. Zalecamy zachowanie minimalnej przestrzeni wentylacyjnej 1U bezpośrednio nad szafą lub instalację wewnętrznych wentylatorów obudowy, aby zapobiec przeciążeniu termicznemu i zminimalizować zużycie elektrolitycznych kondensatorów wygładzających zasilacza.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZawsze używaj wysokiej czystości, wielożyłowego przewodu miedzianego 14 AWG, aby sprostać wysokim wymaganiom prądowym przy dolnym progu 20 V DC. Przed włączeniem zasilania upewnij się, że uziemienie instrumentu i obudowy szafy są solidnie połączone w jednym punkcie, aby zapobiec pętlom masy, które mogłyby wprowadzać wysokoczęstotliwościowe zakłócenia do sąsiednich kart wibracyjnych maszyn.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-weight: bold;\"\u003eOSTRZEŻENIE KRYTYCZNE: ZAGROŻENIE ELEKTRYCZNE\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eUpewnij się, że wszystkie główne wyłączniki zasilania niskiego napięcia są całkowicie odłączone od zasilania, zablokowane i oznakowane (LOTO) przed podłączeniem lub odłączeniem listwy zaciskowej. Nieprzestrzeganie zabezpieczenia źródła zasilania może spowodować łuk elektryczny na zaciskach, uszkodzenie tylnej płyty systemu oraz obrażenia personelu.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eDelikatnie wsunąć moduł o połowie wysokości do wyznaczonych lewych gniazd zasilania w obudowie szafy 3500, aż pewnie osadzi się w złączach tylnej płyty.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eRęcznie dokręć zintegrowane śruby mocujące na przednim panelu, aby mechanicznie zabezpieczyć moduł przed wibracjami.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003ePodłącz zewnętrzne przewody zasilające 24 V DC do odpowiednich zacisków na listwie zaciskowej wejściowej z tyłu szafy, zachowując ścisłą ostrożność, aby utrzymać prawidłową polaryzację (+\/-).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eWłącz wyłącznik obwodu zasilania i potwierdź, że zielona dioda LED OK na przednim panelu świeci, co wskazuje na prawidłowe napięcie wyjściowe.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668296397163,"sku":"3500\/15-04-04-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-04-04-CN-4ljvmm0twaq_e8410d9d-454e-46bb-a770-d9e5805459ec.jpg?v=1765520407"},{"product_id":"bently-nevada-3500-15-05-00-cn-universal-ac-power-supply-module","title":"Moduł zasilania uniwersalnego prądu przemiennego Bently Nevada 3500\/15-05-00-CN","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e3500\/15-05-00-CN\u003c\/strong\u003e to moduł o połowie wysokości zaprojektowany do zasilania Systemu Ochrony Maszyn Serii 3500. Musi być zainstalowany w wyznaczonych slotach po lewej stronie szafy 3500, aby przekształcić szeroki zakres napięć wejściowych na regulowane napięcia wymagane przez inne moduły systemu. Moduł \u003cstrong\u003e3500\/15-05-00-CN\u003c\/strong\u003e działa jako uniwersalny zasilacz AC i współpracuje z uniwersalnym modułem wejścia zasilania AC (PIM). Szafa 3500 może pomieścić pojedynczy zasilacz lub dwa zasilacze redundantne. W konfiguracji podwójnej moduł w dolnym slocie pełni funkcję zasilacza podstawowego, natomiast moduł w górnym slocie służy jako zasilacz zapasowy. Praca redundantna umożliwia wyjmowanie lub wkładanie dowolnego modułu zasilania bez zakłócania działania systemu.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFormat o połowie wysokości optymalizuje wykorzystanie przestrzeni w szafie.\u003c\/li\u003e\n\u003cli\u003eRedundantna zdolność zasilania zapewnia bezproblemowe automatyczne przełączenie zapasowe przy zainstalowaniu dwóch modułów.\u003c\/li\u003e\n\u003cli\u003eKonstrukcja umożliwiająca wymianę na gorąco pozwala na wkładanie i wyjmowanie modułu bez przerywania pracy szafy.\u003c\/li\u003e\n\u003cli\u003eDioda LED \"Supply OK\" na przednim panelu zapewnia bezpośrednie wizualne potwierdzenie prawidłowej pracy modułu.\u003c\/li\u003e\n\u003cli\u003eOchrona przed przepięciem powoduje przepalenie bezpiecznika w PIM, izolując system od szkodliwych poziomów napięcia.\u003c\/li\u003e\n\u003cli\u003eOchrona przed niskim napięciem zapewnia, że warunki niskiego napięcia nie uszkodzą zasilacza ani modułu PIM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOchrona i monitorowanie stanu turbin\u003c\/li\u003e\n\u003cli\u003eInstrumentacja drgań turbin gazowych i parowych w elektrowniach\u003c\/li\u003e\n\u003cli\u003eOchrona obrotowych zasobów rafinerii ropy i gazu\u003c\/li\u003e\n\u003cli\u003eSystemy monitorowania maszyn w zakładach petrochemicznych\u003c\/li\u003e\n\u003cli\u003eSystemy ochrony ciężkich sprężarek i pomp przemysłowych\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOpcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eKod\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Typ zasilacza (górny slot)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eUniwersalne napięcie AC (85 do 264 Vac rms) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Typ zasilacza (dolny slot)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak zasilania (używane, gdy zasilanie nie jest wymagane) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne napięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 do 220 Vac nominalnie \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego (bezpieczny)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 do 264 Vac rms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego (niebezpieczny)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 do 250 Vac rms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSzczytowe napięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 do 373 Vac pk \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęstotliwość wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 do 63 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePobór prądu pełnej szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,8 A rms (maksymalnie) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary zasilacza (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga zasilacza\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu wejścia zasilania (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 25,4 mm x 114,3 mm (4,75 cala x 1,0 cala x 4,5 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu wejścia zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,34 kg (0,75 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNie jest wymagane minimalne obciążenie szafy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eElement \/ Zacisk\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED zasilania OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWskaźnik na panelu przednim, który świeci, gdy zasilanie działa prawidłowo.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUniwersalne zaciski PIM AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTylne połączenia dla linii (LN) i neutralnego (NEUT) wejść wysokiego napięcia AC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunkt połączenia ochronnego uziemienia na PIM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGniazdo bezpiecznika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZawiera wymienny bezpiecznik ochrony przed przepięciem głównym.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePozycjonowanie w szafie:\u003c\/strong\u003e Instaluj moduł tylko w dedykowanych slotach o połowie wysokości, znajdujących się po lewej stronie szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDopasowanie PIM:\u003c\/strong\u003e Upewnij się, że powiązany uniwersalny moduł wejścia zasilania AC (PIM) jest zamontowany bezpośrednio za modułem zasilania z tyłu obudowy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział redundancji:\u003c\/strong\u003e W konfiguracjach redundantnych umieść główne zasilanie w dolnym slocie, a zapasowe zasilanie w górnym slocie.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Podłącz system uziemienia konstrukcyjnego solidnie do tylnego zacisku uziemienia PIM, aby zmniejszyć zakłócenia elektryczne i zapewnić bezpieczeństwo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSprawdzenie kompatybilności:\u003c\/strong\u003e Upewnij się, że uniwersalne zasilanie AC i odpowiadający mu moduł PIM nie są mieszane ani krzyżowo łączone z tradycyjnymi komponentami Bently Nevada wysokiego\/niska napięcia AC, ponieważ są niekompatybilne.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e 2014\/30\/UE \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy EMC:\u003c\/strong\u003e EN 61000-6-2 (odporność na zakłócenia w środowiskach przemysłowych), EN 61000-6-4 (emisje w środowiskach przemysłowych) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Dyrektywa niskonapięciowa 2014\/35\/UE, EN 61010-1 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Dyrektywa ROHS 2011\/65\/UE \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKlasyfikacje morskie:\u003c\/strong\u003e Zasady klasyfikacji DNV GL (statki, jednostki offshore, szybkie i lekkie jednostki), zasady ABS dotyczące warunków klasyfikacji (część 1, statki stalowe, jednostki i konstrukcje offshore)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668296921451,"sku":"3500\/15-05-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-05-00-CN-33kctsgmty0_587dbb73-ddaa-4ade-8efe-36a58bf56ee8.jpg?v=1765520425"},{"product_id":"bently-nevada-3500-15-02-00-00-high-voltage-ac-power-supply-module","title":"Moduł zasilania prądem przemiennym wysokiego napięcia Bently Nevada 3500\/15-02-00-00","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/15-02-00-00\u003c\/strong\u003e jest modułem zasilacza wysokiego napięcia AC zaprojektowanym dla systemu ochrony maszyn serii 3500. Ten moduł o połowie wysokości instaluje się w specjalnych slotach po lewej stronie szafy 3500, aby przekształcić wysokie napięcie AC wejściowe na regulowane napięcia wymagane przez inne moduły systemu. Działa jako pojedynczy zasilacz lub w konfiguracji redundantnej z dwoma zasilaczami, \u003cstrong\u003e3500\/15-02-00-00\u003c\/strong\u003e zapewnia nieprzerwaną pracę szafy. W konfiguracji podwójnej dolny slot zawiera zasilacz podstawowy, a górny slot zasilacz zapasowy; usunięcie lub włożenie któregokolwiek modułu nie zakłóca działania systemu. Ta konkretna konfiguracja wykorzystuje moduł wejściowy wysokiego napięcia AC (PIM) i obsługuje nominalne napięcie wejściowe 220 Vac rms.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModuł o połowie wysokości, maksymalizujący efektywność wykorzystania przestrzeni w szafie.\u003c\/li\u003e\n\u003cli\u003eMożliwość redundantnego zasilania z automatycznym przełączaniem zapasowym.\u003c\/li\u003e\n\u003cli\u003eMożliwość wymiany na gorąco, pozwalająca na usunięcie i włożenie modułu bez zakłócania pracy szafy.\u003c\/li\u003e\n\u003cli\u003eWskaźnik LED \"Supply OK\" na przednim panelu do monitorowania statusu operacyjnego w czasie rzeczywistym.\u003c\/li\u003e\n\u003cli\u003eZintegrowana ochrona przed przepięciami, która przepala bezpiecznik modułu wejściowego, chroniąc wewnętrzne komponenty.\u003c\/li\u003e\n\u003cli\u003eOchrona przed niskim napięciem zapewniająca, że warunki niskiego napięcia nie uszkodzą zasilacza ani PIM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystemy ochrony turbin\u003c\/li\u003e\n\u003cli\u003eMonitorowanie aktywów rafinerii ropy i gazu\u003c\/li\u003e\n\u003cli\u003eMonitorowanie drgań i stanu turbin wytwarzających energię\u003c\/li\u003e\n\u003cli\u003eOchrona maszyn w zakładach petrochemicznych\u003c\/li\u003e\n\u003cli\u003eMonitorowanie ciężkich obrotowych urządzeń przemysłowych\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOpcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eKod\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Typ zasilacza (górny slot)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eWysokie napięcie AC (175 do 264 Vac rms) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Typ zasilacza (dolny slot)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak zasilacza (używane, gdy wymagany jest tylko jeden zasilacz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Opcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (General Electric Company) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp napięcia wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWysokie napięcie AC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne napięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 Vac nominalne \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 do 264 Vac rms (247 do 373 Vac pk) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego (Legacy)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 do 250 Vac rms (dla PIM przed Rev. R \/ zasilacza przed Rev. M) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęstotliwość wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 do 63 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePobór prądu pełnej szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,3 A rms (maksymalnie) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary zasilacza (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga zasilacza\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu wejścia zasilania (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 25,4 mm x 114,3 mm (4,75 cala x 1,0 cala x 4,5 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu wejścia zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,34 kg (0,75 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNie jest wymagane minimalne obciążenie szafy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKońcówka zacisku \/ komponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED na panelu przednim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDioda LED OK zasilania wskazuje prawidłową pracę zasilacza.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLN1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWejście linii zasilania AC 1 na module PIM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLN2 \/ NEUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWejście linii zasilania AC 2 \/ połączenie neutralne na module PIM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePołączenie ochronnego uziemienia.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZacisk bezpiecznika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZawiera bezpiecznik SB 250V \/ 6,25A do ochrony przed przepięciami.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMontaż w szafie:\u003c\/strong\u003e Instaluj moduły zasilania o połowie wysokości wyłącznie w specjalnie zaprojektowanych slotach po lewej stronie szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuł wejścia zasilania:\u003c\/strong\u003e Zamontuj powiązany moduł wejścia zasilania AC wysokiego napięcia (PIM) w pozycji obudowy bezpośrednio za głównym modułem zasilania.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja redundancji:\u003c\/strong\u003e Przy stosowaniu dwóch zasilaczy do redundancji umieść zasilacz główny w dolnym slocie, a zapasowy w górnym slocie.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUziemienie:\u003c\/strong\u003e Solidnie połącz uziemienie konstrukcyjne z zaciskiem GND na tylnym module zasilania, aby zminimalizować zakłócenia elektromagnetyczne i zapewnić bezpieczeństwo elektryczne.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOchrona przed przepięciami:\u003c\/strong\u003e Upewnij się, że źródło zasilania nie przekracza 264 Vac rms, ponieważ warunki przepięciowe spowodują przepalenie bezpiecznika ochronnego na module PIM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swapping:\u003c\/strong\u003e Podczas wymiany modułów upewnij się, że co najmniej jedno źródło zasilania pozostaje aktywne i działa, aby zapobiec przestojom systemu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy EMC:\u003c\/strong\u003e EN 61000-6-2 (Odporność na zakłócenia w środowiskach przemysłowych), EN 55011\/CISPR 11 (Sprzęt ISM), EN 61000-6-4 (Emisje w środowiskach przemysłowych) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy Wspólnoty Europejskiej:\u003c\/strong\u003e Dyrektywa EMC 2004\/108\/WE \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e EN 61010-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668297052523,"sku":"3500\/15-02-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-02-00-00-3pyfxp4zqcy_97359eac-3a88-40e1-bdd3-fec2cbb6307a.jpg?v=1765520429"},{"product_id":"bently-nevada-3500-04-01-3500-04-internal-barriers-earthing-module","title":"Moduł uziemienia wewnętrznych barier Bently Nevada 3500\/04-01 3500\/04","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModel \u003cstrong\u003e3500\/04-01 (zastąpiony przez 3500\/04-01-00)\u003c\/strong\u003e zapewnia intrinsicznie bezpieczne (IS) połączenie uziemienia przez szynę tylną systemu 3500 dla systemów czujników podłączonych bezpośrednio do systemu ochrony maszyn. Ten \u003cstrong\u003e3500\/04 Moduł uziemienia wewnętrznych barier\u003c\/strong\u003e jest niezbędnym elementem każdej konfiguracji szafy 3500, która zawiera intrinsicznie bezpieczne moduły I\/O wewnętrznych barier. Zapewniając dedykowaną ścieżkę o niskiej impedancji do uziemienia systemu, gwarantuje prawidłowe rozpraszanie prądu zwarciowego i ochronę przed wybuchem w instalacjach w strefach zagrożenia, nie pogarszając ogólnej wydajności monitora. Urządzenie wymaga dedykowanego miejsca I\/O w szynie tylnej szafy, tworząc scentralizowaną sieć uziemienia bezpieczeństwa, która wspiera kompleksową integrację czujników w zastosowaniach ochrony maszyn przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsicznie bezpieczna infrastruktura uziemienia:\u003c\/strong\u003e Zapewnia scentralizowany, wysokiej integralności intrinsicznie bezpieczny punkt odniesienia uziemienia bezpośrednio przez szynę tylną szafy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegralna architektura systemu:\u003c\/strong\u003e Zaprojektowany jako wewnętrzny komponent szafy monitora, aby utrzymać pełną wydajność systemu bez konieczności stosowania zewnętrznych barier uziemiających.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedykowane zabezpieczenie pozycji:\u003c\/strong\u003e Integruje się z dedykowanym miejscem monitora, aby zabezpieczyć integralność uziemienia krytycznego dla bezpieczeństwa w całym układzie szafy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKompatybilność modułów mieszanych:\u003c\/strong\u003e Wspiera bezproblemową współpracę standardowych i intrinsycznie bezpiecznych modułów I\/O wewnętrznych barier w tej samej infrastrukturze szafy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBezpieczne uziemienie intrinsycznie bezpiecznych systemów barierowych czujników zbliżeniowych i sejsmicznych \u003c\/li\u003e\n\u003cli\u003eOchrona maszyn w strefach zagrożenia i systemy izolacji wybuchowej \u003c\/li\u003e\n\u003cli\u003eCentralne uziemienie szyny tylniej dla monitorów wewnętrznych barier termopar i RTD \u003c\/li\u003e\n\u003cli\u003eSieci monitorowania drgań i położenia maszyn przemysłowych wymagające zgodności IS \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/04-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł uziemienia wewnętrznych barier (zawiera panel przedni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ch4\u003eMechaniczne\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWartość\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł uziemienia wewnętrznych barier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,1 cm x 2,44 cm x 10,31 cm (9,50 in. x 0,96 in. x 4,06 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,201 kg (0,443 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZajętość slotu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWymaga 1 dedykowanej pozycji monitora o pełnej wysokości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eŚrodowiskowy\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWartość\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C do +65°C (-4°F do +149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePin złącza \/ komponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfejs panelu przedniego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIdentyfikacja modułu i mocowanie przedniego panelu szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfejs złączowy płyty tylnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane, wysokiej integralności, iskrobezpieczne połączenie uziemienia do płaszczyzny uziemienia szafy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedykowane przypisanie slotu:\u003c\/strong\u003e Moduł musi być zainstalowany w dedykowanym miejscu monitora w standardowej obudowie 3500. To dedykowane miejsce ogranicza standardową szafę 19-calową do maksymalnie 13 dostępnych pozycji monitorów.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePozycjonowanie do konserwacji:\u003c\/strong\u003e Umieść urządzenie w slocie szafy, który umożliwia łatwy i niezakłócony dostęp do rutynowych procedur konserwacji online i inspekcji.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIzolacja i odstępy separacyjne:\u003c\/strong\u003e Gdy standardowe moduły I\/O lub moduł uziemiający są umieszczone pomiędzy parą modułów I\/O z barierą wewnętrzną, należy zachować minimalny odstęp dwóch wolnych pozycji w szafie, aby umożliwić dostęp online bez zakłócania sąsiednich wiązek przewodów.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWymagania dotyczące aktualizacji oprogramowania:\u003c\/strong\u003e Projekty modernizacji szaf migracji standardowych modułów do konfiguracji z barierą wewnętrzną wymagają wersji 2.3 lub nowszej oprogramowania konfiguracyjnego 3500 Rack wraz z określonymi wersjami firmware dla starszych monitorów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Zgodność z częścią 15 przepisów FCC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa EMC:\u003c\/strong\u003e Dyrektywa Wspólnoty Europejskiej 2014\/30\/UE; Normy: EN 61000-6-2 (odporność przemysłowa) oraz EN 61000-6-4 (emisje przemysłowe).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Dyrektywa niskonapięciowa Wspólnoty Europejskiej 2014\/35\/UE zgodna z normą EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa RoHS:\u003c\/strong\u003e Zgodność z dyrektywą Wspólnoty Europejskiej 2011\/65\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenie morskie:\u003c\/strong\u003e ABS Marine i zastosowania offshore; Zasady DNV GL dotyczące klasyfikacji statków i jednostek offshore.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożenia:\u003c\/strong\u003e Klasa I, Podział 2, Grupy A, B, C i D; Klasa I, Strefa 2: AEx\/Ex nA nC ic IIC T4 Gc oraz AEx\/Ex ec nC ic IIC T4 Gc; ATEX\/IECEx Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4\/T5 Gc (T4 przy Ta = -20°C do +65°C).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668297150827,"sku":"3500\/04-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350004-01-m5pxtjwlw3w_b470c6ac-1c14-4ade-95ae-b0f6f6538a13.jpg?v=1765520433"},{"product_id":"bently-nevada-3500-15-01-01-01-low-voltage-ac-power-supply-module","title":"Moduł zasilania niskonapięciowego prądu przemiennego Bently Nevada 3500\/15-01-01-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł zasilacza \u003cstrong\u003eBently Nevada 3500\/15-01-01-01\u003c\/strong\u003e to moduł o połowie wysokości, zaprojektowany do montażu po lewej stronie szafy ochrony maszyn serii 3500. Moduł ten przetwarza zewnętrzne, niskonapięciowe zasilanie AC na regulowane napięcia DC wymagane do zasilania wszystkich innych aktywnych modułów w tej samej szafie. Pojedynczy zasilacz \u003cstrong\u003e3500\/15\u003c\/strong\u003e jest elektrycznie przystosowany do samodzielnego zasilania w pełni obciążonej szafy. Gdy dwa moduły są zainstalowane jednocześnie w wyznaczonych slotach, działają w konfiguracji redundantnej. W tej architekturze z dwoma zasilaczami moduł w dolnym slocie pełni funkcję głównego źródła zasilania, natomiast moduł w górnym slocie działa jako automatyczny zapasowy zasilacz.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWsparcie pracy redundantnej\u003c\/strong\u003e: Umożliwia instalację identycznego modułu zapasowego w drugim slocie szafy, zapewniając płynne przejęcie zasilania w przypadku awarii bez przestojów systemu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuł wymienny na gorąco\u003c\/strong\u003e: Umożliwia wyjęcie lub włożenie dowolnego modułu zasilania bez przerywania pracy urządzeń w szafie, pod warunkiem, że drugi sprawny zasilacz pozostaje aktywny.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZintegrowana diagnostyka\u003c\/strong\u003e: Diody LED \"SUPPLY OK\" na przednim panelu zapewniają wizualne potwierdzenie prawidłowego działania zasilacza w czasie rzeczywistym.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOchrona przed przekroczeniem zakresu\u003c\/strong\u003e: Wbudowana ochrona zapewnia, że stan niskiego napięcia nie powoduje uszkodzeń strukturalnych ani funkcjonalnych wewnętrznego obwodu ani powiązanego modułu zasilania (PIM).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystemy ochrony maszyn i monitorowania stanu.\u003c\/li\u003e\n\u003cli\u003eTurbiny do wytwarzania energii i sprężarki przemysłowe.\u003c\/li\u003e\n\u003cli\u003eMaszyny do rafinacji ropy i gazu.\u003c\/li\u003e\n\u003cli\u003eLinie produkcyjne ciężkiego przemysłu wytwórczego.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKomponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15\u003c\/td\u003e\n\u003ctd\u003eModuł zasilacza 3500\/15 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp zasilacza (górny slot)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eNiskie napięcie AC (85 do 132 Vac rms) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp zasilacza (dolny slot)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eNiskie napięcie AC (85 do 132 Vac rms) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZatwierdzenie agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C (Klasa 1, Podział 2) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ch4\u003eSpecyfikacje elektryczne\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWartość\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne napięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 Vac nominalne \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 do 132 Vac rms (120 do 188 Vac pk) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNapięcie wejściowe (starszy sprzęt)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 do 125 Vac rms (dla PIM przed Rev. R i zasilacza przed Rev. M) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęstotliwość wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 do 63 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePełne obciążenie prądu racka\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,5 A rms (maksymalnie) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOchrona przed przepięciem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowoduje przepalenie bezpiecznika w PIM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eFizyczne i środowiskowe\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWartość\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu zasilającego (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu zasilającego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu zasilania (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 25,4 mm x 114,3 mm (4,75 cala x 1,0 cala x 4,5 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,34 kg (0,75 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimity wilgotności\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne obciążenie racka\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNie jest wymagane minimalne obciążenie racka \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmiejscowienie gniazd\u003c\/strong\u003e: Moduły zasilania muszą być instalowane wyłącznie w wyznaczonych gniazdach o połowie wysokości, znajdujących się w lewej części racka 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuł zasilania (PIM)\u003c\/strong\u003e: Dopasowany moduł zasilania o połowie wysokości musi być umieszczony i solidnie przymocowany bezpośrednio za głównym modułem zasilania z tyłu obudowy racka.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDwutorowe zasilanie\u003c\/strong\u003e: Przy wdrażaniu konfiguracji redundantnej upewnij się, że linia podstawowa jest podłączona do dolnego gniazda modułu, a linia zapasowa do górnego gniazda modułu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormy EMC\u003c\/strong\u003e: EN 61000-6-2 (Odporność na zakłócenia w środowiskach przemysłowych), EN 61000-6-4 (Emisje w środowiskach przemysłowych) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy Wspólnoty Europejskiej\u003c\/strong\u003e: Dyrektywa EMC 2014\/30\/EU, Dyrektywa LV 2014\/35\/EU \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne\u003c\/strong\u003e: EN 61010-1 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożonych\u003c\/strong\u003e: CSA\/NRTL\/C Klasa I, Podział 2, Grupy A, B, C, D (T4 @ Ta = -20°C do +65°C \/ -4°F do +150°F) \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668298494315,"sku":"3500\/15-01-01-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-15-01-01-01-f5154zdokoq_d41b0f0a-e8ef-4ebb-bc25-81328c632f8d.jpg?v=1765520484"},{"product_id":"bently-nevada-3500-32-01-00-3500-series-4-channel-relay-module","title":"Moduł przekaźnikowy Bently Nevada 3500\/32-01-00 serii 3500, 4-kanałowy","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZapewniając programowalne wyjścia alarmowe przekaźników w ramach systemu ochrony maszyn, \u003cstrong\u003eBently Nevada 3500\/32-01-00\u003c\/strong\u003e działa jako wysoce niezawodny 4-kanałowy interfejs przekaźnikowy dla systemu ochrony maszyn 3500. Konfiguracja ta obejmuje zapasowy moduł sterujący \u003cstrong\u003e149986-02\u003c\/strong\u003e oraz zapasowy moduł wyjścia przekaźnikowego \u003cstrong\u003e125720-02\u003c\/strong\u003e. Każdy kanał może być niezależnie programowany za pomocą równań logicznych do wyzwalania wyłączeń lub sekwencji alarmowych na podstawie sygnałów statusu z sąsiednich modułów monitorujących w szafie. System opiera się na zintegrowanej łączności szynowej, aby ominąć opóźnienia komunikacji zewnętrznej, realizując operacje krytyczne dla bezpieczeństwa z deterministyczną dokładnością.\u003c\/p\u003e\n\n\u003ch3\u003eKluczowe cechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eCztery w pełni niezależne, programowalne programowo wyjścia przekaźnikowe typu SPDT (Single Pole Double Throw).\u003c\/li\u003e\n  \u003cli\u003eModułowa konstrukcja dzieląca przetwarzanie logiki (moduł sterujący) i fizyczne interfejsy połączeń (moduł I\/O).\u003c\/li\u003e\n  \u003cli\u003eWysoko konfigurowalna logika głosowania (AND, OR oraz kombinacje notarialne) definiowana za pomocą oprogramowania 3500 Rack Configuration Software.\u003c\/li\u003e\n  \u003cli\u003eWbudowane wskaźniki LED na przednim panelu wyświetlają statusy OK w czasie rzeczywistym oraz indywidualne aktywacje przekaźników.\u003c\/li\u003e\n  \u003cli\u003eObsługuje konfiguracje okablowania normalnie załączonego (wyłączanie do wyzwolenia) lub normalnie wyłączonego (załączanie do wyzwolenia).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania przemysłowe\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSystemy awaryjnego wyłączania i nadprędkościowe turbiny.\u003c\/li\u003e\n  \u003cli\u003eBlokady bezpieczeństwa sprężarek tłokowych i odśrodkowych.\u003c\/li\u003e\n  \u003cli\u003ePomocnicze obwody sterowania dużych wentylatorów przemysłowych i dmuchaw.\u003c\/li\u003e\n  \u003cli\u003eZarządzanie alarmami temperatury uzwojeń generatora i silnika.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eWartość specyfikacji\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNumer modelu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3500\/32-01-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eKarty komponentów\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e149986-02 (moduł sterujący) + 125720-02 (moduł I\/O)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eLiczba kanałów\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4 przekaźniki SPDT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParametry styków przekaźnika (rezystancyjne)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5 A przy 240 VAC (50\/60 Hz) \/ 5 A przy 30 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eZużycie energii\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5,8 W (typowo)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOpcja zatwierdzeń agencji\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-00 (Brak)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePrzewidywana żywotność przekaźnika\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 000 cykli przy obciążeniu znamionowym\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTemperatura pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-30°C do +65°C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUSA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2,20 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eWymiary opakowania (obliczone)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e29,2 cm x 15,4 cm x 10,2 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003ePołączenia okablowania i przypisania zacisków\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOznaczenie zacisku\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eKanał przekaźnika\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003ePrzypisanie funkcji\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0;\"\u003eKanał 1 - NZ \/ Wsp \/ NO\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0;\"\u003ePrzekaźnik 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStyki normalnie zamknięte \/ wspólne \/ normalnie otwarte\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0;\"\u003eKanał 2 - NZ \/ Wsp \/ NO\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0;\"\u003ePrzekaźnik 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStyki normalnie zamknięte \/ wspólne \/ normalnie otwarte\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0;\"\u003eKanał 3 - NZ \/ Wsp \/ NO\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0;\"\u003ePrzekaźnik 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStyki normalnie zamknięte \/ wspólne \/ normalnie otwarte\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0;\"\u003eKanał 4 - NZ \/ Wsp \/ NO\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-right: 1px solid #e2e8f0;\"\u003ePrzekaźnik 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStyki normalnie zamknięte \/ wspólne \/ normalnie otwarte\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpiryczne spostrzeżenia inżynierskie\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eModel 149986-02 jest zmodernizowanym, bezpośrednim zamiennikiem starszych rewizji kart sterujących, takich jak 125712-01. Przy wymianie pojedynczych komponentów zamiast całego zespołu 3500\/32, potwierdź, że wersja oprogramowania układowego zaprogramowana w 149986-02 jest kompatybilna z istniejącą płytą tylnego panelu szafy oraz wersją Twojego oprogramowania 3500 System Configuration.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePodczas przełączania obciążeń indukcyjnych (takich jak ciężkie elektromagnesy blokad lub pośrednie styczniki pomocnicze) wyładowania łukowe na stykach mogą prowadzić do zgrzewania styków lub generowania zakłóceń EMI, które zakłócają sąsiednie kanały monitorujące. Inżynierowie systemowi muszą zainstalować zewnętrzne tłumiki RC lub diody zwrotne na obciążeniu indukcyjnym, aby chronić styki przekaźnika przed wysokonapięciowymi impulsami przejściowymi.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eUpewnij się, że podczas sekwencji uruchamiania szafy dokładnie sprawdzisz stan przekaźników. Skonfigurowane jako „normalnie załączone”, te przekaźniki chwilowo zmienią stan po podaniu zasilania na szafę. Krytyczne linie wyłączania muszą być zabezpieczone blokadą lub tymczasowo obejściem podczas cyklu zasilania, aby zapobiec fałszywym wyłączeniom maszyn.\u003c\/p\u003e\n\n\u003ch3\u003eWytyczne dotyczące instalacji\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eOSTRZEŻENIE KRYTYCZNE\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #2d3748; font-size: 0.95rem;\"\u003eNie wymieniaj modułu I\/O 125720-02 na gorąco, jeśli na którymkolwiek zacisku polowym występuje wysokie napięcie. Całkowicie odizoluj i odłącz od zasilania wszystkie podłączone linie przekaźnikowe przed usunięciem modułu I\/O z tyłu szafy, aby uniknąć niebezpiecznych łuków elektrycznych lub poważnych obrażeń personelu.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 30px; height: 30px; display: flex; align-items: center; justify-content: center;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWyłącz zasilanie szafy 3500 i odłącz wszystkie połączenia zasilania polowego podłączone do bloków zaciskowych 125720-02.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 30px; height: 30px; display: flex; align-items: center; justify-content: center;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWsunąć kartę sterującą 149986-02 do wyznaczonego gniazda z przodu szafy, aż dźwignie wysuwania zatrzasną się.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 30px; height: 30px; display: flex; align-items: center; justify-content: center;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWyrównaj i wsunąć moduł I\/O 125720-02 do odpowiedniego gniazda z tyłu szafy, dokładnie dokręcając oba śruby mocujące.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 30px; height: 30px; display: flex; align-items: center; justify-content: center;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePołącz się z systemem za pomocą oprogramowania 3500 Rack Configuration, aby przypisać kanały i załadować profil walidacji logiki.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668299247979,"sku":"3500\/32-01-00 (125712-01 + 125720-01)","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-32-01-00-2nbs4j5cudb_3befece7-41ca-45db-8702-8adee6bd53aa.jpg?v=1765520495"},{"product_id":"bently-nevada-3500-15-01-01-00-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-01-01-00 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojektowany do integracji w systemie ochrony maszyn 3500, \u003cstrong\u003eBently Nevada 3500\/15-01-01-00\u003c\/strong\u003e pełni funkcję wysoce niezawodnego modułu zasilania. Ten moduł półwysokości przetwarza zasilanie AC na precyzyjne poziomy elektryczne wymagane przez płytę tylnią szafy, zapewniając stabilną pracę wszystkich zainstalowanych modułów monitorujących.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e3500\/15-01-01-00\u003c\/strong\u003e Konfiguracja jest specjalnie zaprojektowana do środowisk niskiego napięcia AC, akceptując zakres wejściowy 85 do 132 Vac rms. Dla aplikacji krytycznych, gdzie ciągłość pracy jest kluczowa, system szafy 3500 obsługuje redundantne konfiguracje zasilania. W jednym stojaku można zainstalować dwa moduły, co umożliwia automatyczne, bezproblemowe przełączenie na zasilanie zapasowe w przypadku awarii źródła podstawowego.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eObsługuje zakres niskiego napięcia AC od 85 do 132 Vac rms.\u003c\/li\u003e\n  \u003cli\u003eZaprojektowany do bezproblemowej kompatybilności z gniazdami standardowej obudowy serii 3500.\u003c\/li\u003e\n  \u003cli\u003eObsługuje redundantne, wymienne na gorąco konfiguracje z podwójnym zasilaniem.\u003c\/li\u003e\n  \u003cli\u003eZapewnia solidną ochronę przed przepięciami, przeciążeniami i zwarciami, chroniąc moduły dalszego stopnia.\u003c\/li\u003e\n  \u003cli\u003eFormat półwysokości optymalizuje zajmowaną powierzchnię w szafie monitorującej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSystemy turbin parowych, gazowych i hydroelektrycznych.\u003c\/li\u003e\n  \u003cli\u003eRafinerie ropy naftowej, przetwórstwo petrochemiczne i monitoring rurociągów.\u003c\/li\u003e\n  \u003cli\u003eObrotowe maszyny w zakładach uzdatniania wody i ścieków.\u003c\/li\u003e\n  \u003cli\u003eSieci ochrony ciężkich maszyn przemysłowych i monitoringu stanu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3500\/15-01-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eModuł zasilania\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNapięcie wejściowe\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85 do 132 Vac rms (niskie napięcie AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCzęstotliwość wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e47 do 63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePółwysokość\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRedundancja\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eObsługiwane (w połączeniu z drugim modułem zasilania)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-30°C do 65°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40°C do 85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95% wilgotności względnej bez kondensacji\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePołączenie zaciskowe\u003c\/th\u003e\n      \u003cth\u003eFunkcja\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eL\u003c\/td\u003e\n      \u003ctd\u003eWejście AC fazowe \/ liniowe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eN\u003c\/td\u003e\n      \u003ctd\u003eWejście AC neutralne\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGND\u003c\/td\u003e\n      \u003ctd\u003eUziemienie ochronne \/ Masa obudowy\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacji\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMontaż modułu zasilania wyłącznie w wyznaczonych lewych gniazdach obudowy 3500.\u003c\/li\u003e\n  \u003cli\u003eSprawdź, czy linia zasilająca odpowiada specyfikacji niskiego napięcia 85 do 132 Vac rms przed włączeniem obwodu.\u003c\/li\u003e\n  \u003cli\u003eZapewnij niskooporowe połączenie z głównym zaciskiem ochronnym uziemienia z tyłu szafy, aby zmaksymalizować odporność na zakłócenia i bezpieczeństwo.\u003c\/li\u003e\n  \u003cli\u003eUtrzymuj wolną przestrzeń wentylacyjną wokół obudowy szafy, aby zapewnić odpowiednie chłodzenie konwekcyjne.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eZgodny z CE\u003c\/li\u003e\n  \u003cli\u003eCertyfikat UL\/CSA\u003c\/li\u003e\n  \u003cli\u003eZatwierdzony przez ATEX\/IECEx do stref zagrożenia 2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668300886379,"sku":"3500\/15-01-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-15-01-01-00-ifowddhfhvf_30467887-398f-43aa-ac92-b2a227789377.jpg?v=1765520539"},{"product_id":"3500-33-01-cn-bently-nevada-3500-series-16-channel-relay-module","title":"Moduł przekaźnikowy 16-kanałowy Bently Nevada 3500\/33-01-CN serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZaprojketowany jako solidny, wysokogęstościowy interfejs sterujący dla sieci awaryjnego wyłączania maszyn, Bently Nevada 3500\/33-01-CN zapewnia krytyczne cyfrowe wyjścia w systemie ochrony maszyn serii 3500. Ten \u003cstrong\u003e16-kanałowy moduł wyjściowy przekaźnika\u003c\/strong\u003e oferuje wysoce konfigurowalną logikę głosowania bezpośrednio powiązaną z monitorowanymi parametrami drgań, temperatury lub prędkości. Każdy kanał przekaźnika może być programowany niezależnie, aby przekształcać stany alarmowe w twardo okablowane działania korygujące, zapewniając niezawodność wyłączenia maszyny w ekstremalnych warunkach pracy.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e16 niezależnych przekaźników:\u003c\/strong\u003e Umożliwia gęste konfiguracje monitoringu bez konieczności stosowania dodatkowych zewnętrznych paneli przekaźnikowych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZaawansowane głosowanie alarmowe:\u003c\/strong\u003e Wysoce konfigurowalne opcje logicznego głosowania (np. 1 z 1, 2 z 3 lub niestandardowe kombinacje) konfigurowalne przez oprogramowanie.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZgodność z agencjami:\u003c\/strong\u003e Certyfikowane z zatwierdzeniami specyficznymi dla kraju \"CN\", spełniające surowe lokalne normy inżynieryjne i wymogi bezpieczeństwa.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDedykowane wskaźniki na panelu przednim:\u003c\/strong\u003e Wyraźne, dobrze widoczne diody LED zapewniają bieżącą informację o stanie każdego kanału wyjściowego i stanu modułu.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWyjścia o wysokiej integralności:\u003c\/strong\u003e Przeznaczone do niezawodnej, długotrwałej pracy przełączającej w wysokotemperaturowych, ciągłych instalacjach przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTurbiny parowe i gazowe:\u003c\/strong\u003e Wykonuje natychmiastowe sygnalizowanie awaryjnego wyłączenia podczas przekroczenia prędkości lub wysokich drgań.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKompresory odśrodkowe i osiowe:\u003c\/strong\u003e Interfejsuje z sieciami antyprzepływowymi i systemami sterowania awaryjnego wyłączania (ESD).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePompy i silniki ciężkiego typu:\u003c\/strong\u003e Zapewnia suche styki blokad do pomocniczych pętli sterowania, systemów smarowania i wyłączników elektrycznych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZakłady petrochemiczne i elektrownie:\u003c\/strong\u003e Działa jako fizyczny interfejs bariery awaryjnej między monitorami stanu maszyn a rozproszonymi systemami sterowania (DCS).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTabela specyfikacji technicznych\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eWartość \/ Specyfikacja\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumer modelu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3500\/33-01-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTyp modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł wyjściowy przekaźnika 16-kanałowy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOpcja wyjścia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e01 (Moduł wyjściowy przekaźnika 16-kanałowy)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZatwierdzenia agencji\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCN (Zatwierdzenia specyficzne dla kraju \/ Chiny)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTemperatura pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTemperatura przechowywania\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWilgotność względna\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e95% bez kondensacji\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUSA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3,0 kg (6,6 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpiryczne spostrzeżenia inżynierskie\u003c\/h3\u003e\n\u003ch4\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eModuł 3500\/33-01-CN jest funkcjonalnie identyczny z standardowymi wariantami 3500\/33-01, ale posiada lokalne zatwierdzenia (przyrostek \"CN\" oznacza specyficzne normy zgodności). Upewnij się, że podczas wymiany istniejącego modułu na miejscu dokumentacja sterująca odpowiada dokładnemu przyrostkowi zatwierdzenia, aby uniknąć lokalnych niezgodności. Zawsze sprawdzaj, czy oprogramowanie konfiguracyjne szafy 3500 oraz firmware modułu interfejsu szafy (RIM) są aktualne, aby w pełni obsługiwały profile diagnostyczne tego modułu.\u003c\/p\u003e\n\n\u003ch4\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePodczas przełączania obciążeń indukcyjnych (takich jak ciężkie zawory elektromagnetyczne lub styczniki pomocnicze) z czasem może dochodzić do erozji styków z powodu wyładowań łukowych. Dla obciążeń indukcyjnych przekraczających nominalną wartość zaleca się instalację zewnętrznych obwodów tłumiących łuk (tłumiki lub diody zwrotne), aby maksymalnie wydłużyć żywotność wewnętrznych styków suchych. Upewnij się, że moduł jest skonfigurowany na stan bezpieczny (normalnie zasilany) lub bez stanu bezpiecznego (normalnie bez zasilania) zgodnie z matrycą systemu bezpieczeństwa instrumentacji (SIS) w twoim zakładzie.\u003c\/p\u003e\n\n\u003ch4\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZawsze prowadź linie sterujące stykami przekaźnika o dużym prądzie w oddzielnych rurach lub korytkach kablowych, z dala od wysoce czułych kabli wejściowych niskiego poziomu (takich jak sondy zbliżeniowe lub okablowanie akcelerometrów). To fizyczne oddzielenie zapobiega przesłuchom elektromagnetycznym i potencjalnemu wprowadzeniu zakłóceń do kanałów pomiarowych podczas przełączania styków.\u003c\/p\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eOSTRZEŻENIE KRYTYCZNE\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eOdłącz wszystkie źródła zasilania do szafy 3500 i odłącz zasilanie zewnętrznych styków przekaźnika wysokiego napięcia przed instalacją lub demontażem tego modułu. Praca na podłączonych przewodach może spowodować porażenie prądem, niezamierzone wyłączenia maszyn lub natychmiastowe uszkodzenie sprzętu.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eUpewnij się, że szkielet systemu 3500 jest prawidłowo uziemiony zgodnie ze standardowymi przepisami elektrycznymi zakładu.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eDelikatnie wsuwaj główny moduł 3500\/33 do wyznaczonego gniazda tylnego\/przedniego szkieletu, zapewniając prawidłowe ustawienie prowadnic karty.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eDokładnie dokręć śruby mocujące moduł, aby zabezpieczyć instalację fizyczną i utrzymać ciągłość elektryczną szkieletu.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003ePodłącz zewnętrzny blok zacisków przekaźnika do tylnego modułu i dokręć wszystkie połączenia zacisków zgodnie ze standardowymi specyfikacjami momentu obrotowego.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668301836651,"sku":"3500\/33-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350033-01-CN-fkrevd0gtyi_3efe6a1f-dbcf-4033-b1b9-9b157fc69d6e.jpg?v=1765520563"},{"product_id":"bently-nevada-3500-15-03-03-00-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-03-03-00 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Zaprojketowany do dostarczania zasilania płyty dla systemu ochrony maszyn 3500, Bently Nevada 3500\/15-03-03-00 to moduł o półwysokości przeznaczony do środowisk monitoringu przemysłowego o wysokiej dostępności. Ta konkretna konfiguracja działa z wysokim napięciem DC na obu slotach, górnym i dolnym, tworząc solidną podstawę zasilania. Zapewniając stałe, regulowane napięcia dla wszystkich modułów w szafie, utrzymuje integralność systemu i zapewnia nieprzerwane monitorowanie krytycznych wirujących urządzeń.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eWsparcie podwójnej redundancji przy zainstalowaniu dwóch modułów w płycie redundantnej.\u003c\/li\u003e\n  \u003cli\u003eDedykowane wejścia wysokiego napięcia DC dla obu pozycji slotów.\u003c\/li\u003e\n  \u003cli\u003eWbudowane filtry zakłóceń elektromagnetycznych (EMI) zapobiegające propagacji szumów elektrycznych.\u003c\/li\u003e\n  \u003cli\u003eZintegrowane obwody ochrony przed przepięciami, przeciążeniem i zwarciem.\u003c\/li\u003e\n  \u003cli\u003eWskaźniki LED na przednim panelu do natychmiastowego monitorowania stanu zasilania.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSystemy ochrony turbin parowych i gazowych.\u003c\/li\u003e\n  \u003cli\u003eDuże przemysłowe systemy monitorowania sprężarek i pomp.\u003c\/li\u003e\n  \u003cli\u003eElektrownie wodne i cieplne.\u003c\/li\u003e\n  \u003cli\u003eObiekty petrochemiczne i wirujące maszyny rafinerii ropy naftowej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 35%;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNumer modelu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500\/15-03-03-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeria\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTyp zasilacza (górny slot)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWysokie napięcie DC (88 do 140 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTyp zasilacza (dolny slot)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWysokie napięcie DC (88 do 140 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eZatwierdzenia agencji\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBrak (opcja 00)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eZakres napięcia wejściowego\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e88 do 140 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFormat\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModuł o półwysokości\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWaga netto modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1,39 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3,00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eStany Zjednoczone\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eModele alternatywne i kompatybilność\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Moduł zasilania 3500\/15 musi być zainstalowany w obudowie serii 3500 zawierającej kompatybilną płytę zasilającą. W przypadku migracji ze starszych systemów z pojedynczym zasilaniem na układ zasilania redundantnego, należy upewnić się, że fizyczna płyta zasilająca została zaktualizowana do wersji redundantnej. Moduły wysokiego napięcia DC są funkcjonalnie wymienne z innymi konfiguracjami napięć (takimi jak niskie napięcie DC lub wysokie napięcie AC), pod warunkiem, że podstawowa płyta zasilająca i okablowanie źródła są zgodne z odpowiednimi wartościami napięcia.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Przy doborze źródła DC zasilającego wejścia 88 do 140 V DC upewnij się, że zdolność prądowa impulsowa jest wystarczająca do obsługi początkowych skoków zasilania szafy lub obciążeń przejściowych podczas gorącej wymiany modułów. Praca tego zasilacza w wysokotemperaturowych, niewentylowanych obudowach (powyżej 50°C) skróci żywotność wewnętrznych kondensatorów filtrujących. Utrzymuj swobodny przepływ powietrza wokół obudowy szafy, aby zapobiec tworzeniu się gorących punktów termicznych.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Dla prawdziwej fizycznej redundancji poprowadź zasilanie wejściowe dla górnych i dolnych gniazd z niezależnych źródeł elektrycznych (np. oddzielne panele dystrybucji DC). Zawsze stosuj dedykowane zewnętrzne wyłączniki obwodowe do izolowania pojedynczych usterek. Uziem obudowę bezpośrednio do niskoomowego szyny uziemiającej zakładu za pomocą przewodu miedzianego o przekroju co najmniej 2,5 mm2 (14 AWG), aby zredukować wysokoczęstotliwościowe zakłócenia elektryczne, które mogłyby pogorszyć pomiary sondy zbliżeniowej.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eWytyczne dotyczące instalacji\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e\n  \u003cspan style=\"color: #9b2c2c;\"\u003e\n    Odłącz i zablokuj wszystkie źródła zasilania elektrycznego zasilające od góry, zanim spróbujesz zainstalować, usunąć lub podłączyć ten moduł. Źródła wysokiego napięcia DC (88 do 140 V DC) stanowią poważne zagrożenie porażeniem elektrycznym. Zweryfikuj całkowity brak napięcia za pomocą skalibrowanego przyrządu przed dotknięciem jakichkolwiek zacisków.\n  \u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWsuń moduł zasilacza 3500\/15 mocno do dedykowanego gniazda zasilania po lewej stronie obudowy szafy 3500, aż całkowicie osadzi się w złączach tylnej płyty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eDokładnie dokręć śruby motylkowe na przednim panelu za pomocą śrubokręta płaskiego, aby zapewnić stabilne uziemienie mechaniczne i zapobiec poluzowaniu spowodowanemu drganiami.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePodłącz linie zasilania DC do odpowiednich zacisków na tylnym bloku zaciskowym, stosując zalecane wartości momentu dokręcania i sprawdzając polaryzację.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668302295403,"sku":"3500\/15-03-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-03-03-00-53l1cltjmof_a990bd21-54d5-49a1-a37f-3cb4d597e70b.jpg?v=1765520578"},{"product_id":"bently-nevada-3500-15-03-05-00-3500-15-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-03-05-00 3500\/15","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojektowany do dostarczania wysoce stabilnego zasilania magistrali, \u003cstrong\u003eBently Nevada 3500\/15-03-05-00\u003c\/strong\u003e działa jako kluczowy moduł o połowie wysokości w systemie ochrony maszyn serii 3500. Ten moduł zasilający przetwarza napięcia wejściowe na precyzyjne poziomy wymagane przez magistralę, zapewniając niezawodną, ciągłą pracę wszystkich zainstalowanych monitorów i modułów keyphasor. Konfiguracja \u003cstrong\u003e3500\/15-03-05-00\u003c\/strong\u003e obsługuje podwójne źródła zasilania, umożliwiając architekturę redundantną, w której zasilanie zapasowe może natychmiast przejąć obciążenie w przypadku awarii głównego źródła, zapobiegając przestojom całego systemu.\u003c\/p\u003e\n\n\u003cp\u003eUmieszczony po lewej stronie szafy 3500, moduł ma dedykowane górne i dolne gniazda do obsługi różnych źródeł zasilania. Ta konkretna wersja posiada opcję wejścia wysokiego napięcia DC na górnym gnieździe oraz uniwersalne wejście AC na dolnym gnieździe, oferując doskonałą kompatybilność z różnorodnymi przemysłowymi stacjami transformatorowymi i infrastrukturą zasilania zakładu bez potrzeby stosowania zewnętrznych przetworników.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eWspiera redundantne konfiguracje zasilania z automatyczną, bezproblemową ochroną przełączenia awaryjnego.\u003c\/li\u003e\n  \u003cli\u003eObsługuje różne opcje napięcia w odrębnych górnych i dolnych gniazdach.\u003c\/li\u003e\n  \u003cli\u003eChroni elektronikę wewnętrzną szafy przed przepięciami, nadnapięciami i zakłóceniami elektromagnetycznymi.\u003c\/li\u003e\n  \u003cli\u003eZaprojektowany do instalacji na gorąco, umożliwiającej utrzymanie pracy systemu podczas konserwacji.\u003c\/li\u003e\n  \u003cli\u003eZapewnia wskaźniki LED na panelu przednim do natychmiastowego monitorowania stanu zasilania i warunków OK.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSystemy ochrony turbin w rafineriach ropy i gazu.\u003c\/li\u003e\n  \u003cli\u003eCiągłe monitorowanie drgań i stanu w elektrowniach cieplnych.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie krytycznego sprzętu obrotowego w oczyszczalniach wody i zakładach chemicznych.\u003c\/li\u003e\n  \u003cli\u003eOchrona ciężkich maszyn przemysłowych wykorzystująca platformę Bently Nevada 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOznaczenie kodu opcji\u003c\/th\u003e\n      \u003cth\u003eSkonfigurowana wartość parametru\u003c\/th\u003e\n      \u003cth\u003eSzczegóły specyfikacji technicznej\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e03 (górne gniazdo)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZasilanie wysokiego napięcia DC\u003c\/td\u003e\n      \u003ctd\u003e88 do 140 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e05 (dolne gniazdo)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUniwersalne zasilanie AC\u003c\/td\u003e\n      \u003ctd\u003e85 do 264 Vac rms (47 do 63 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOpcja zatwierdzeń agencji\u003c\/td\u003e\n      \u003ctd\u003eBrak\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParametr\u003c\/th\u003e\n      \u003cth\u003eWartość specyfikacji\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części\/model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3500\/15-03-05-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeria produktu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSystem ochrony maszyn serii 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNapięcie wejściowe górnego gniazda\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e88 do 140 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNapięcie wejściowe dolnego gniazda\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85 do 264 Vac rms (nominalnie 120\/220 Vac, 47 do 63 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMożliwość redundancji zasilania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKonfiguracja dwuslotowa kompatybilna z redundantnymi systemami zasilania\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-30°C do +65°C (-22°F do +150°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40°C do +85°C (-40°F do +185°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95% bez kondensacji\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12,07 cm x 5,08 cm x 25,15 cm (4,75 cala x 2,00 cala x 9,90 cala)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWaga modułu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,39 kg (3,06 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUpewnij się, że zasilanie racka 3500 jest wyłączone lub przestrzegaj odpowiednich procedur bezpieczeństwa przy wymianie na gorąco przed instalacją modułu.\u003c\/li\u003e\n  \u003cli\u003eWłóż moduł 3500\/15 do dedykowanych gniazd zasilania po lewej stronie obudowy racka.\u003c\/li\u003e\n  \u003cli\u003eDokładnie dokręć śruby mocujące moduł do obudowy, aby zapewnić optymalne połączenie elektryczne i stabilność mechaniczną.\u003c\/li\u003e\n  \u003cli\u003eSprawdź, czy doprowadzone linie zasilające (wysokie napięcie DC i uniwersalne AC) odpowiadają określonym parametrom zacisków przed podłączeniem zasilania.\u003c\/li\u003e\n  \u003cli\u003eUżywaj odpowiednio ekranowanych i dobranych kabli zasilających zgodnych z lokalnymi przemysłowymi normami elektrycznymi.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668302492011,"sku":"3500\/15-03-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-15-03-05-00-1e3gx4xwqiz_7e5fbf3f-050a-4772-bd51-e3c0b873e0f4.jpg?v=1765520585"},{"product_id":"bently-nevada-3500-15-01-00-00-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-01-00-00 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZapewniając niezawodną konwersję i kondycjonowanie zasilania dla systemu ochrony maszyn 3500, \u003cstrong\u003eBently Nevada 3500\/15-01-00-00\u003c\/strong\u003e to moduł zasilacza o półwysokości, zaprojektowany do środowisk monitoringu przemysłowego o wysokiej dostępności. Ta konkretna konfiguracja jest zaprojektowana do akceptacji \u003cstrong\u003eniskonapięciowego wejścia AC\u003c\/strong\u003e, przekształcając zasilanie sieciowe na regulowane napięcia DC wymagane przez magistralę i zainstalowane karty monitorujące. Zaprojektowany do zastosowań w krytycznych maszynach obrotowych, zapewnia ciągłość działania i integralność sygnału dla krytycznych szaf ochronnych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMożliwość niskonapięciowego AC:\u003c\/strong\u003e Specjalnie zaprojektowany dla zasilaczy użyteczności publicznej w zakresie 85 do 132 Vac rms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModułowa architektura:\u003c\/strong\u003e Półwysoki fizyczny design pozwala na efektywne wykorzystanie slotów w standardowej ramie szafy 3500.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIzolacja zasilania:\u003c\/strong\u003e Posiada wysoką odporność elektromagnetyczną, chroniącą komponenty szafy przed przepięciami i przejściowymi zakłóceniami linii.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElastyczna konfiguracja:\u003c\/strong\u003e Skonfigurowany jako pojedyncza (nieredundantna) opcja zasilania, idealna dla architektur zakładów niekrytycznych lub standardowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eSystemy monitorowania drgań w rafineriach ropy naftowej i zakładach petrochemicznych.\u003c\/li\u003e\n  \u003cli\u003eZakłady wytwarzania energii z turbinami parowymi lub gazowymi monitorujące zespoły.\u003c\/li\u003e\n  \u003cli\u003eZakłady wodociągowe i ściekowe wykorzystujące scentralizowane systemy ochrony maszyn obrotowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eWartość\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeria modelu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem ochrony maszyn serii 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTyp zasilacza (01)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNiskonapięciowe AC (85 do 132 Vac rms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eZakres częstotliwości\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e47 do 63 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOpcja zasilania wtórnego (00)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBrak zasilania (dla konfiguracji z pojedynczym zasilaczem)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eZatwierdzenia agencji (00)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBrak\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eStany Zjednoczone (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4,00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWymiary opakowania (obliczone)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e25,0 cm x 15,0 cm x 10,0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eModele alternatywne i kompatybilność\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDziedziczny moduł niskonapięciowy AC Bently Nevada 3500\/15-01-00-00 został oficjalnie zastąpiony przez ulepszony \u003cstrong\u003e3500\/15-05-00-00\u003c\/strong\u003e zasilacz. Nowszy model posiada zoptymalizowany wewnętrzny układ regulacji zaprojektowany dla wyższej efektywności termicznej. Podczas modernizacji lub wymiany starszych jednostek upewnij się, że wszelkie towarzyszące redundantne zasilacze mają identyczną klasę napięcia wejściowego, aby uniknąć potencjalnych problemów z obciążeniem magistrali.\u003c\/p\u003e\n\n\u003ch3\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo urządzenie jest skonfigurowane do \u003cstrong\u003epracy z pojedynczym zasilaniem\u003c\/strong\u003e (opcja wtórna -00). W krytycznych architekturach ochrony, gdzie niedostępność szafy jest niedopuszczalna, należy zastosować konfiguracje z podwójną redundancją. Praca szafy z pojedynczym zasilaniem naraża system na całkowitą utratę monitoringu w przypadku spadku napięcia lub lokalnej awarii komponentu w linii zasilającej. Zawsze zapewnij odpowiednią przestrzeń wentylacyjną nad i pod szafą 3500, aby odprowadzać ciepło, ponieważ przegrzanie może przedwcześnie uszkodzić wewnętrzne kondensatory filtrujące modułu.\u003c\/p\u003e\n\n\u003ch3\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eLinie zasilające muszą być prowadzone przez dedykowany, zewnętrzny wyłącznik dwubiegunowy umieszczony blisko szafy, aby zapewnić bezpieczną izolację podczas konserwacji. Do zasilania AC używaj wysokiej jakości ekranowanych kabli, aby zapobiec przenikaniu zakłóceń elektromagnetycznych do sąsiednich kabli czujników niskonapięciowych. Uziemienie obudowy na tylnej płycie szafy 3500 musi być bezpośrednio połączone z niskoomowym uziemieniem systemu pomiarowego, aby zapewnić stabilną pracę i prawidłową ochronę przeciwprzepięciową.\u003c\/p\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eOSTRZEŻENIE KRYTYCZNE\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eOdłącz wszystkie pierwotne źródła zasilania AC i zabezpiecz je blokadą\/etykietą przed usunięciem, włożeniem lub podłączaniem tego modułu. Na listwie zaciskowej i tylnej płycie podczas pracy systemu występują niebezpieczne napięcia. Niepełne odłączenie zasilania może spowodować poważne obrażenia ciała lub uszkodzenie sprzętu.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eUpewnij się, że główny wyłącznik obwodu zasilającego szafę 3500 jest całkowicie wyłączony i oznaczony.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eDelikatnie wsuwaj moduł 3500\/15-01-00-00 do wyznaczonego gniazda po lewej stronie szafy 3500, aż całkowicie osadzi się w złączach tylnej płyty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eDokładnie dokręć śruby mocujące obudowę, aby uziemić przedni panel i zapobiec wibracjom mechanicznym, które mogłyby wypchnąć moduł z miejsca.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePodłącz przewody zasilania AC do zacisków wejściowych, dokładnie sprawdzając wszystkie polaryzacje i połączenia uziemienia przed włączeniem zasilania.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668302721387,"sku":"3500\/15-01-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-01-00-00-psg3244fce0_fba6248e-9d2e-44d2-beb3-f7358ce374e7.jpg?v=1765520592"},{"product_id":"bently-nevada-149986-01-3500-33-spare-16-channel-relay-control-module","title":"Moduł sterujący przekaźnikami zapasowymi Bently Nevada 149986-01 3500\/33, 16-kanałowy","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e149986-01\u003c\/strong\u003e jest zapasowym modułem przednim pełnej wysokości zaprojektowanym dla 3500\/33 16-kanałowego modułu przekaźnikowego w systemie ochrony maszyn serii 3500. Moduł ten zapewnia podstawową logikę sterowania i funkcje napędowe niezbędne do zarządzania 16 niezależnymi wyjściami przekaźnikowymi używanymi do krytycznych alarmów maszyn i konfiguracji logiki głosowania. Montuje się go bezpośrednio w dowolnym przednim miejscu obudowy po prawej stronie modułu Transient Data Interface (TDI) i współpracuje z modułem I\/O zamontowanym z tyłu, aby łączyć się z zewnętrznym okablowaniem polowym. \u003cstrong\u003e149986-01\u003c\/strong\u003e przetwarza sygnały wejściowe z kanałów monitorujących w szafie i wykorzystuje programowalną logikę sterowania alarmami, obsługując zarówno operacje AND, jak i OR na podstawie indywidualnych zmierzonych zmiennych, statusów alertu lub zagrożenia oraz warunków Not-OK.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrzetwarza indywidualne lub połączone zmienne kanałów monitorujących do sterowania złożoną logiką alarmową.\u003c\/li\u003e\n\u003cli\u003eW pełni programowalne konfiguracje logiki głosowania zarządzane za pomocą oprogramowania konfiguracyjnego 3500 Rack.\u003c\/li\u003e\n\u003cli\u003eWskaźniki stanu na panelu przednim, w tym dedykowana dioda LED OK dla stanu systemu oraz dioda TX\/RX do monitorowania komunikacji w szafie.\u003c\/li\u003e\n\u003cli\u003eZapewnia wysoką gęstość alarmów w pojedynczym module przednim pełnej wysokości w obudowie 3500.\u003c\/li\u003e\n\u003cli\u003eBezproblemowa integracja z systemami bezpieczeństwa funkcjonalnego wymagającymi ograniczonych napięć wyjściowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWysokogęstościowe przetwarzanie alarmów i logiki głosowania w systemach ochrony maszyn przemysłowych.\u003c\/li\u003e\n\u003cli\u003eOchrona krytycznych zasobów rafinerii wymagająca automatycznego wyłączania lub powiadamiania o alarmie.\u003c\/li\u003e\n\u003cli\u003eSieci głosowania bezpieczeństwa turbin gazowych i parowych w elektrowniach.\u003c\/li\u003e\n\u003cli\u003eAutomatyczne monitorowanie środowisk bezpieczeństwa funkcjonalnego (SIL).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e149986-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZapasowy 16-kanałowy moduł sterowania przekaźnikami \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł przedni pełnej wysokości \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 5,8 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 242 mm (9,50 cala x 0,96 cala x 9,52 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,7 kg (1,6 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C do +65°C (-4°F do +149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania dotyczące miejsca w szafie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowy przedni slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKomponent \/ dioda LED\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZapala się, gdy moduł sterujący działa prawidłowo.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiga podczas operacji nadawania i odbioru podczas komunikacji z innymi modułami w szafie.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED alarmu kanału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndywidualne wskaźniki, które zapalają się, gdy konkretny kanał przekaźnika jest w stanie alarmu.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmiejscowienie w szafie:\u003c\/strong\u003e Zainstaluj moduł sterujący \u003cstrong\u003e149986-01\u003c\/strong\u003e wyłącznie w przednim, pełnowymiarowym slocie po prawej stronie modułu Transient Data Interface (TDI) w szafie.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZakaz gorącej wymiany:\u003c\/strong\u003e Nie wkładaj modułu na gorąco w żadnych okolicznościach. Przed serwisowaniem upewnij się, że zasilanie szafy jest odłączone lub wyizolowane, aby zapobiec uszkodzeniu modułu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKontrola wersji oprogramowania:\u003c\/strong\u003e Upewnij się, że oprogramowanie konfiguracyjne 3500 Rack jest zaktualizowane do wersji 3.3 lub nowszej, a oprogramowanie do akwizycji danych do wersji 2.40 lub nowszej przed uruchomieniem.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyładowania elektrostatyczne (ESD):\u003c\/strong\u003e Zawsze używaj opaski uziemiającej na nadgarstek podczas obsługi modułu sterującego, aby zapobiec uszkodzeniu wrażliwej mikroelektroniki wewnętrznej przez wyładowania elektrostatyczne.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Zgodność z częścią 15 przepisów FCC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e 2014\/30\/UE (normy: EN 61000-6-2, EN 61000-6-4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Dyrektywa niskonapięciowa 2014\/35\/UE (norma: EN 61010-1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Dyrektywa ROHS 2011\/65\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMorski:\u003c\/strong\u003e Zasady DNV GL dotyczące klasyfikacji (statki, jednostki offshore, szybkie i lekkie jednostki pływające); Zasady ABS dotyczące warunków klasyfikacji Część 1 (stalowe statki, jednostki i konstrukcje offshore).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożonych:\u003c\/strong\u003e Klasa I, Strefa 2 (AEx\/Ex nA nC ic IIC T4 Gc \/ AEx\/Ex ec nC ic IIC T4 Gc); Klasa I, Podział 2, Grupy A, B, C i D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex II 3 G (Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668303475051,"sku":"149986-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/149986-01-eilcrhj53ry_fad1f76d-9de1-420a-adfa-017ccb904af8.jpg?v=1765520619"},{"product_id":"bently-nevada-125712-01-4-channel-relay-module","title":"Moduł przekaźnikowy 4-kanałowy Bently Nevada 125712-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e125712-01\u003c\/strong\u003e to pełnowymiarowy zapasowy komponent zaprojektowany do zapewnienia czterech niezależnych wyjść przekaźnikowych w ramach \u003cstrong\u003eSystemu Ochrony Maszyn Serii 3500\u003c\/strong\u003e. Moduł ten działa poprzez wykonywanie wysoce konfigurowalnej logiki głosowania bezpośrednio sterowanej przez alerty maszynowe i poziomy zagrożenia w całej obudowie systemu. Każde wyjście terminala zawiera specjalistyczną logikę sterowania alarmem, którą można dostosować za pomocą złożonych wyrażeń boolowskich AND lub OR przy użyciu oprogramowania konfiguracyjnego 3500 Rack do zarządzania specyficznymi automatycznymi sygnałami wyzwalającymi. Działa niezawodnie, gdy jest umieszczony po prawej stronie głównego modułu interfejsu szafy, dostarczając dyskretne wyjścia stykowe do łączy sterowania polowego, systemów awaryjnego zatrzymania lub zewnętrznych sygnalizatorów przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCztery w pełni programowalne, niezależne wyjścia przekaźnikowe wspierające złożoną lokalną logikę głosowania systemu.\u003c\/li\u003e\n\u003cli\u003eKonfigurowalna logika sterowania alarmem wykorzystująca kombinacje bramek AND\/OR dla elastycznych działań w stanie maszyny.\u003c\/li\u003e\n\u003cli\u003eKompatybilność wielokanałowa, akceptująca sygnały alarmowe i ostrzegawcze z dowolnej aktywnej karty monitorującej w lokalnej szafie.\u003c\/li\u003e\n\u003cli\u003eDiagnostyka wizualna na panelu przednim, w tym dedykowane diody LED dla statusu modułu OK, aktywnej komunikacji TX\/RX oraz indywidualnych wskaźników stanu przekaźnika.\u003c\/li\u003e\n\u003cli\u003ePrzekaźnik o wysokiej integralności, uszczelniony epoksydowo, wykorzystujący pary przekaźników SPDT w jednolitej fizycznej konfiguracji DPDT.\u003c\/li\u003e\n\u003cli\u003eFunkcjonalność wybierana przełącznikiem sprzętowym do ustawiania kanałów na normalnie załączone (NE) lub normalnie wyłączone (NDE).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechaniczne systemy wyzwalania i integracja awaryjnego wyłączania.\u003c\/li\u003e\n\u003cli\u003eZautomatyzowane przemysłowe systemy logiki głosowania i alarmowania dla dużych wirujących urządzeń.\u003c\/li\u003e\n\u003cli\u003eKrytyczne sieci blokad ochronnych turbin i sprężarek przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNumer części \/ opcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/32-A01-B00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-kanałowy moduł przekaźnika z modułem I\/O, bez zatwierdzeń agencji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/32-A01-B01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-kanałowy moduł przekaźnika z modułem I\/O, zatwierdzenie CSA\/NRTL\/C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125712-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZapasowy moduł 4-kanałowego przekaźnika (płyta główna) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125720-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZapasowy moduł I\/O 4-kanałowego przekaźnika \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580436\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZłącze nagłówkowe, zakończenie wewnętrzne, 6-pozycyjne, zielone \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKategoria\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDane\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElektryczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZużycie energii\u003c\/td\u003e\n\u003ctd\u003eTypowo 6 watów \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTyp przekaźnika\u003c\/td\u003e\n\u003ctd\u003eDwa przekaźniki SPDT połączone w konfiguracji DPDT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUszczelnienie środowiskowe\u003c\/td\u003e\n\u003ctd\u003eUszczelnione epoksydowo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTłumik łuku\u003c\/td\u003e\n\u003ctd\u003e250 Vrms, standardowo zainstalowane \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParametry styków\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksymalny prąd przełączania\u003c\/td\u003e\n\u003ctd\u003e5 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaksymalne napięcie przełączane (DC)\u003c\/td\u003e\n\u003ctd\u003e30 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaksymalne napięcie przełączane (AC)\u003c\/td\u003e\n\u003ctd\u003e250 V AC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaksymalna moc przełączana (DC)\u003c\/td\u003e\n\u003ctd\u003e120 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaksymalna moc przełączana (AC)\u003c\/td\u003e\n\u003ctd\u003e600 VA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMinimalny prąd przełączany\u003c\/td\u003e\n\u003ctd\u003e10 mA przy 5 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eŻywotność styku\u003c\/td\u003e\n\u003ctd\u003e100 000 cykli przy 5 A, 24 V DC lub 120 V AC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŚrodowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22 °F do +150 °F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40 °F do +185 °F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWilgotność\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechaniczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWymiary modułu głównego (W x S x G)\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 242 mm (9,50 cala x 0,96 cala x 9,52 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWaga modułu głównego\u003c\/td\u003e\n\u003ctd\u003e0,7 kg (1,6 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMiejsce w szafie (moduł główny)\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe przednie gniazdo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMiejsce w szafie (moduł I\/O)\u003c\/td\u003e\n\u003ctd\u003e1 pełnowymiarowe tylne gniazdo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOznaczenie zacisku\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZacisk styku normalnie zamkniętego do pętli urządzeń zewnętrznych \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eARM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZacisk styku ramienia (wspólny) do okablowania zewnętrznego \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZacisk styku normalnie otwartego do pętli urządzeń zewnętrznych \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTRYB PRZEKAŹNIKA (Przełącznik)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzełączniki sprzętowe do wyboru trybu Normalnie Rozłączony (NDE) lub Normalnie Załączony (NE) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział gniazda:\u003c\/strong\u003e Umieść moduł w dowolnym dostępnym gnieździe pełnowymiarowym bezpośrednio po prawej stronie modułu interfejsu 3500 Rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja trybu przekaźnika:\u003c\/strong\u003e Przed uruchomieniem skonfiguruj indywidualne przełączniki sprzętowe kanałów na module, aby określić tryb pracy jako Normalnie Rozłączony (NDE) lub Normalnie Załączony (NE) w zależności od typu urządzenia polowego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja oprogramowania:\u003c\/strong\u003e Użyj oprogramowania 3500 Rack Configuration Software do mapowania konkretnych kombinacji alarmów ostrzegawczych lub niebezpieczeństwa na kanałach monitorujących do lokalnej logiki alarmowej modułu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmisje EMC:\u003c\/strong\u003e EN 55011 Klasa A (emisje promieniowane i przewodzone).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOdporność EMC:\u003c\/strong\u003e IEC61000-6-2, EN 61000-4-2 (Kryteria wyładowań elektrostatycznych B), ENV 50140 (Kryteria podatności na promieniowanie A), ENV 50141 (Kryteria podatności przewodzonej A), EN 61000-4-4 (Kryteria szybkich impulsów elektrycznych B), EN 61000-4-5 (Kryteria odporności na przepięcia B), 61000-4-8 (Kryteria pola magnetycznego A), EN 61000-4-11 (Kryteria spadków napięcia B), ENV 50204 (Kryteria radiotelefonu B).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWymagania bezpieczeństwa:\u003c\/strong\u003e EN 61010-1 Dyrektywy niskonapięciowe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożenia:\u003c\/strong\u003e CSA\/NRTL\/C; Klasa I, Podział 2, Grupy A, B, C, D; T4 @ Ta = -20°C do +65°C. Numer certyfikatu: CSA 150268-1002151 (LR 26744).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668304163179,"sku":"125712-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/125712-01-3hn5dg1p5b3_b85f00b9-fdb5-4862-9d7a-fff51b8b3767.jpg?v=1765520643"},{"product_id":"bently-nevada-106m1079-01-universal-ac-power-supply-module","title":"Moduł zasilania uniwersalnego prądu przemiennego Bently Nevada 106M1079-01","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eStabilna regulacja napięcia i stałe dostarczanie mocy są kluczowe dla systemów monitorowania maszyn, co model \u003cstrong\u003e106M1079-01\u003c\/strong\u003e realizuje jako wysoce niezawodny przemysłowy moduł zasilania. Zaprojektowany przez Bently Nevada, ten \u003cstrong\u003eUniwersalny moduł zasilania AC\u003c\/strong\u003e przetwarza prąd zmienny na stabilne, regulowane zasilanie niezbędne do obsługi sprzętu monitorującego, systemów backplane i podłączonych czujników.\u003c\/p\u003e\n\n\u003cp\u003eZaprojektowany, by sprostać rygorystycznym wymaganiom zakładów przemysłowych, model 106M1079-01 posiada zintegrowane obwody ochronne, które chronią sprzęt końcowy przed wahaniami napięcia i impulsami przejściowymi. Jego konstrukcja fizyczna umożliwia bezpieczne dopasowanie do standardowych obudów systemowych, zapewniając niezawodne połączenie mechaniczne i elektryczne nawet w środowiskach o dużych wibracjach.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSzeroki zakres uniwersalnego wejścia AC kompatybilny z globalnymi standardami sieci przemysłowych.\u003c\/li\u003e\n  \u003cli\u003eSolidna konstrukcja rozpraszania ciepła odpowiednia do zamkniętych środowisk szaf rack.\u003c\/li\u003e\n  \u003cli\u003eZintegrowane obwody ochrony przed przepięciami, przeciążeniem prądowym i zwarciami.\u003c\/li\u003e\n  \u003cli\u003eMechaniczne wyrównanie na gorąco umożliwiające szybkie konserwacje i minimalne przestoje systemu.\u003c\/li\u003e\n  \u003cli\u003ePrzemysłowa osłona minimalizująca zakłócenia elektromagnetyczne (EMI) wrażliwej elektroniki monitorującej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSystemy monitorowania stanu turbin i wytwarzania energii.\u003c\/li\u003e\n  \u003cli\u003eZakłady rafineryjne ropy i gazu wymagające ciągłej ochrony majątku.\u003c\/li\u003e\n  \u003cli\u003eZakłady przetwórstwa chemicznego wykorzystujące czujniki drgań i położenia.\u003c\/li\u003e\n  \u003cli\u003eObudowy do diagnostyki i sterowania ciężkimi maszynami przemysłowymi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e106M1079-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUniwersalny moduł zasilania AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWysokość\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120,7 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSzerokość\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50,8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGłębokość\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e251,5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,39 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cp\u003ePodczas instalacji lub wymiany modułu zasilania uniwersalnego AC 106M1079-01 przestrzegaj następujących procedur inżynieryjnych:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUpewnij się, że obudowa hosta lub szafa monitorująca jest uziemiona zgodnie z lokalnymi przepisami elektrycznymi i normami krajowymi.\u003c\/li\u003e\n  \u003cli\u003eSprawdź, czy napięcie wejściowe AC odpowiada specyfikacjom systemu przed włączeniem modułu.\u003c\/li\u003e\n  \u003cli\u003eNie blokuj ścieżek wentylacyjnych karty zasilającej, aby zapewnić naturalne chłodzenie konwekcyjne.\u003c\/li\u003e\n  \u003cli\u003eDokładnie dokręć wszystkie śruby mocujące do określonego momentu, aby zachować integralność uziemienia i zabezpieczyć moduł przed wibracjami.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668307210603,"sku":"106M1079-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/106m1079-01-ve3zpz3zrys_aa2fdc5e-2ab7-4306-83bb-16097c2fc327.jpg?v=1765520708"},{"product_id":"bently-nevada-3500-15-01-00-01-low-voltage-ac-power-supply-module","title":"Moduł zasilania niskonapięciowego prądu przemiennego Bently Nevada 3500\/15-01-00-01","description":"\n\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModel \u003cstrong\u003e3500\/15-01-00-01\u003c\/strong\u003e to komponent półwysokiej szafy instrumentacyjnej, który przekształca szeroki zakres napięć wejściowych na regulowane napięcia wymagane przez inne moduły funkcjonalne w systemie ochrony maszyn serii 3500. Ta konkretna konfiguracja \u003cstrong\u003emodułu zasilania\u003c\/strong\u003e oferuje opcję modułu niskiego napięcia AC przeznaczoną do górnego slotu, w połączeniu z opcją pustego lub pojedynczego zasilania dla dolnego slotu, i posiada zatwierdzenia bezpieczeństwa dla stref zagrożenia Ameryki Północnej.\u003c\/p\u003e\n\u003cp\u003eSystem mieści do dwóch modułów jednocześnie, tworząc redundantną infrastrukturę. Gdy dwa urządzenia są zamontowane w jednej obudowie, karta w dolnym slocie zarządza operacjami podstawowymi, natomiast karta w górnym slocie działa jako automatyczne źródło zapasowe. W pełni redundantnych konfiguracjach wyjęcie lub włożenie pojedynczego zasilacza obudowy nie przerywa procedur ochrony maszyn ani nie zakłóca pracy szafy.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZapewnia pełną regulowaną dystrybucję zasilania w obudowie z pojedynczym miejscem o wysokości pół slotu.\u003c\/li\u003e\n\u003cli\u003eObsługuje instalację z podwójnym zasilaniem wymienianym na gorąco, zapewniając nieprzerwane monitorowanie stanu.\u003c\/li\u003e\n\u003cli\u003eWbudowana ochrona przed przepięciami, która powoduje przerwanie bezpiecznika na module wejściowym podczas anomalii przepięciowych.\u003c\/li\u003e\n\u003cli\u003eZintegrowane ograniczenia bezpieczeństwa podnapięciowego zapobiegające uszkodzeniom wewnętrznych obwodów podczas spadków napięcia.\u003c\/li\u003e\n\u003cli\u003ePrzejrzyste śledzenie diagnostyczne na przednim panelu z dedykowanym wskaźnikiem stanu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystemy ochrony i diagnostyki wysokodostępnych maszyn przemysłowych.\u003c\/li\u003e\n\u003cli\u003eLinie monitorowania turbin gazowych i parowych w elektrowniach wymagające redundantnego zasilania instrumentów.\u003c\/li\u003e\n\u003cli\u003eZakłady rafineryjne ropy, gazu i chemiczne działające zgodnie z wytycznymi stref zagrożenia.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod wyboru\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeria zasilaczy AC i DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTyp zasilania (górny slot): Niskie napięcie AC (85 do 132 Vac rms) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTyp zasilania (dolny slot): Brak zasilania (lub bezpiecznik, gdy wymagane jest tylko jedno zasilanie) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: CSA\/NRTL\/C (Klasa 1, Dywizja 2, Grupy A, B, C, D) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (spółka zależna General Electric Company) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 do 132 Vac rms (120 do 188 Vac pk) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęstotliwość wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 do 63 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePełne obciążenie prądu szafy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksymalny prąd 4,5 A rms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalne wymagania dotyczące obciążenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNie jest wymagane minimalne obciążenie szafy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C (-22°F do +150°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C (-40°F do +185°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit wilgotności względnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu zasilacza\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,39 kg (3,06 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu wejścia zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,34 kg (0,75 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary zasilacza (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm (4,75 cala x 2,0 cala x 9,9 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu wejścia zasilania (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 25,4 mm x 114,3 mm (4,75 cala x 1,0 cala x 4,5 cala) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania dotyczące przestrzeni w szafie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDwa specjalne sloty o połowie wysokości po lewej stronie szafy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKomponent \/ Wskaźnik\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja \/ Trasowanie\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda LED zasilania OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWskaźnik na panelu przednim, który świeci, gdy zasilacz działa prawidłowo.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModuł wejścia zasilania (PIM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecjalny moduł o połowie wysokości umieszczony bezpośrednio za powiązanym zasilaczem do fizycznego zakończenia kabli.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja slotów:\u003c\/strong\u003e Instaluj aktywny moduł wyłącznie w dedykowanych slotach o połowie wysokości, znajdujących się po lewej stronie obudowy systemu 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRównoważenie układu redundantnego:\u003c\/strong\u003e Przy pracy w konfiguracji z podwójnym zasilaniem umieść główne źródło w dolnym fizycznym slocie zatoki, a pomocniczy sprzęt zapasowy w górnej pozycji odbiorczej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUziemienie elektrostatyczne:\u003c\/strong\u003e Technicy muszą podłączyć się do zweryfikowanego mechanizmu kontroli statycznej na nadgarstek przed otwarciem jakiejkolwiek osłony ochronnej lub wsunięciem kart do ramy tylnej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitorowanie termicznej aeracji:\u003c\/strong\u003e Utrzymuj czyste i otwarte właściwości przepływu powietrza wokół lewej strony struktury kratownicy obudowy, aby potwierdzić, że limity pracy pozostają bezpiecznie poniżej +65°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardy EMC:\u003c\/strong\u003e EN 61000-6-2 (odporność w środowiskach przemysłowych), EN 55011\/CISPR 11, EN 61000-6-4 (emisje).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy europejskie:\u003c\/strong\u003e Dyrektywa EMC 2004\/108\/EC, Dyrektywa niskonapięciowa 2006\/95\/EC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo elektryczne:\u003c\/strong\u003e Zgodność ze standardem EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożonych:\u003c\/strong\u003e CSA\/NRTL\/C Opcja 01: Klasa I, Podział 2, Grupy A, B, C, D; klasyfikacja T4 @ Ta = -20°C do +65°C zgodnie z rysunkiem instalacyjnym referencyjnym 149243.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668307767659,"sku":"3500\/15-01-00-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-15-01-00-01-uqkbpptdlno_2bcaeafd-c665-4f43-9152-d3727ff339b9.jpg?v=1765520729"},{"product_id":"bently-nevada-3500-33-01-00-3500-series-16-channel-relay-module","title":"Moduł przekaźnikowy Bently Nevada 3500\/33-01-00 serii 3500, 16-kanałowy","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZaprojketowany do sygnalizacji alarmowej i wyłączania o wysokiej gęstości, zintegrowany moduł przekaźnikowy \u003cstrong\u003eBently Nevada 3500\/33-01-00\u003c\/strong\u003e stanowi kluczowy węzeł w architekturze ochrony maszyn. Moduł ten oferuje \u003cstrong\u003e16 dyskretnych wyjść przekaźnikowych\u003c\/strong\u003e, które można programować za pomocą wysoce konfigurowalnej logiki głosowania do aktywacji zewnętrznych sygnalizatorów, syren lub systemów awaryjnego wyłączania na podstawie statusów alarmowych z innych modułów w szafie 3500. Przetwarzając sygnały bezpośrednio przez szybki wewnętrzny backplane, zapewnia szybki czas reakcji niezbędny do ochrony maszyn obrotowych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e16 niezależnych wyjść przekaźnikowych:\u003c\/strong\u003e Obsługuje indywidualną konfigurację każdego kanału jako styki normalnie otwarte (NO) lub normalnie zamknięte (NC).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgramowalna logika głosowania:\u003c\/strong\u003e Integruje się z oprogramowaniem konfiguracji szafy 3500, umożliwiając złożone mapowanie logiki AND\/OR z dowolnego kanału monitorującego w systemie.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWskaźniki stanu LED:\u003c\/strong\u003e Aktywna sygnalizacja LED na przednim panelu dla każdego kanału przekaźnikowego, ułatwiająca diagnostykę w czasie rzeczywistym.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpcje podwójnej płytki przekaźnikowej:\u003c\/strong\u003e Wykorzystuje niezawodne przekaźniki jednobiegunowe, dwupozycyjne (SPDT) dla solidnej integralności styków.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProjekt wymienny na gorąco:\u003c\/strong\u003e Umożliwia wymianę modułu w systemach pod pełnym napięciem bez zakłócania pracy sąsiednich kanałów monitorujących.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystemy wyłączania turbin:\u003c\/strong\u003e Automatyczne inicjowanie sekwencji awaryjnego wyłączania turbin parowych i gazowych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOchrona sprężarek i pomp:\u003c\/strong\u003e Przekaźnikowe blokady poleceń z pomocniczymi pompami chłodzącymi lub zaworami obejściowymi.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSygnalizacja w zakładzie przemysłowym:\u003c\/strong\u003e Bezpośrednie kierowanie krytycznych sygnałów alarmowych do systemów sterowania rozproszonego (DCS) w pomieszczeniu kontrolnym oraz obwodów sygnałowych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterfejsowanie stref zagrożenia:\u003c\/strong\u003e Segmentacja alarmów maszyn w strefach bezpiecznych od sieci wyłączania wysokiej energii zakładu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eOpcja modelu \/ przyrostek\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSzczegóły konfiguracji\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł przekaźnikowy 16-kanałowy (jednostka bazowa)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModuł wyjściowy przekaźnikowy 16-kanałowy (standardowe I\/O)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOpcja zatwierdzenia agencji: Brak\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTabela specyfikacji technicznych\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParametr specyfikacji\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eWartość \/ Ocena\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumer części\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3500\/33-01-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKanały przekaźnikowe\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e16 niezależnych wyjść SPDT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZużycie mocy wejściowej\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003enominalnie 5,8 W typowo\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eParametry styków (maks.)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e250 VAC \/ 2 A rezystancyjne; 30 VDC \/ 2 A rezystancyjne\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMoc przełączania\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDo 500 VA \/ 60 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZatwierdzenia agencji\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOpcja 00 (Brak określony)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTemperatura pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-30 do +65 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWymiary netto modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24,20 cm x 2,44 cm x 24,10 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga netto modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0,70 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2,00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStany Zjednoczone Ameryki (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpiryczne spostrzeżenia inżynierskie\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem;\"\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eModuł 3500\/33 jest zaprojektowany do montażu w standardowych pełnowymiarowych ramach Bently Nevada 3500. W przeciwieństwie do modułu przekaźnikowego 3500\/32 z 4 kanałami, który wymagał przypisania do dwóch slotów w niektórych starszych wersjach szaf, moduł 3500\/33 z 16 kanałami optymalizuje przestrzeń, oferując gęstą pojemność sterowania w pojedynczym slocie karty. Zawsze sprawdzaj, czy Twoje oprogramowanie konfiguracyjne szafy 3500 jest zaktualizowane do wersji 3.0 lub wyższej, aby natywnie obsługiwać mapy głosowania 16-kanałowego.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem;\"\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eCzęstym problemem podczas uruchomienia jest używanie wewnętrznych przekaźników do bezpośredniego przełączania indukcyjnych obciążeń ciężkich, takich jak elektromagnesy lub duże styczniki. Chociaż są one ocenione na 2 A przy obciążeniu rezystancyjnym, przełączanie obciążeń indukcyjnych bez zewnętrznej ochrony (np. diod powrotnych lub tłumików RC) może prowadzić do przedwczesnego zgrzewania styków lub nadmiernych zakłóceń EMI, które mogą zakłócać działanie sąsiednich modułów pomiarowych w szafie 3500. Zalecamy stosowanie zewnętrznych przekaźników dla obciążeń o dużym prądzie lub silnie indukcyjnych.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePodczas konfigurowania logiki głosowania upewnij się, że stan „normalnie zasilany” lub „normalnie odłączony” każdego przekaźnika odpowiada Twoim wymaganiom bezpieczeństwa awaryjnego. Styki przekaźników domyślnie przechodzą do stanu odłączonego po całkowitej utracie zasilania szafy 3500. Zamocuj listwę zaciskową pola za pomocą zintegrowanych śrub mocujących, aby uniknąć problemów z rezystancją styków pod wpływem drgań.\u003c\/p\u003e\n\n\u003ch3\u003eWytyczne dotyczące instalacji\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eOSTRZEŻENIE KRYTYCZNE: RYZYKO WYSOKIEGO NAPIĘCIA\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003ePrzed wykonaniem instalacji modułu lub podłączeniem zacisków listwy zaciskowej upewnij się, że wszystkie zewnętrzne obwody zasilania podłączone do listwy zaciskowej przekaźnika są całkowicie odizolowane i zablokowane. Styki przekaźników mogą być podłączone do sieci wysokiego napięcia lub linii awaryjnego wyłączania maszyn, które mogą stanowić zagrożenie porażeniem elektrycznym nawet jeśli sama szafa monitorująca 3500 jest wyłączona.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eZidentyfikuj wolny slot w szafie monitorującej 3500 (z wyłączeniem slotu 1, zarezerwowanego wyłącznie dla modułu interfejsu szafy, oraz slotów zasilania).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eWsuń główny moduł procesora z 16-kanałowym przekaźnikiem do przodu szafy wzdłuż prowadnic kart, aż złącze zostanie pewnie osadzone w płycie tylnej.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eZainstaluj odpowiadający standardowy moduł I\/O z 16-kanałowym przekaźnikiem w odpowiednim slocie z tyłu szafy.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eZabezpiecz śruby mocujące moduły przedni i tylny, aby zapewnić solidne uziemienie szkieletu, następnie ponownie włącz zasilanie szafy i załaduj swoje parametry konfiguracyjne.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308029803,"sku":"3500\/33-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350033-01-00-0djxzltr0qi_33dd5f07-93a2-43c1-aa15-1c45d6fc0e37.jpg?v=1765520739"},{"product_id":"bently-nevada-3500-15-03-02-00-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-03-02-00 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojektowany do ochrony maszyn przemysłowych o wysokiej niezawodności, \u003cstrong\u003e3500\/15-03-02-00\u003c\/strong\u003e zapewnia regulowane zasilanie do tylnej płyty stojaka serii Bently Nevada 3500. Ten moduł o połowie wysokości jest skonfigurowany z podwójnymi wejściami zasilania, aby obsługiwać różne systemy dystrybucji zakładu. Obsługuje źródło wysokiego napięcia DC w górnym gnieździe oraz źródło wysokiego napięcia AC w dolnym gnieździe, zapewniając ciągłą pracę krytycznych systemów monitorowania maszyn nawet podczas przerw w zasilaniu podstawowym.\u003c\/p\u003e\n\n\u003cp\u003eTen \u003cstrong\u003e3500\/15-03-02-00\u003c\/strong\u003e Konfiguracja zasilania obejmuje zasilacz wysokiego napięcia DC w górnym gnieździe (88 do 140 Vdc) oraz zasilacz wysokiego napięcia AC w dolnym gnieździe (175 do 264 Vac rms). W zakładach przeprowadzających modernizacje cyklu życia lub konserwację systemu należy zauważyć, że ta starsza konfiguracja została zastąpiona w obecnej serii produkcyjnej modelem 3500\/15-03-05-00.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElastyczność podwójnego gniazda:\u003c\/strong\u003e Obsługuje wysokie napięcie DC jako zasilanie podstawowe oraz wysokie napięcie AC jako zasilanie pomocnicze w jednym stojaku.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWsparcie redundancji:\u003c\/strong\u003e Stojaki mogą być skonfigurowane z dwoma niezależnymi modułami zasilającymi dla pełnej redundancji i wymiany na gorąco.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOdporność na warunki środowiskowe:\u003c\/strong\u003e Zaprojektowany do niezawodnej pracy w trudnych warunkach przemysłowych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZintegrowany monitoring:\u003c\/strong\u003e Zapewnia ciągłe raportowanie statusu i wskaźniki diagnostyczne bezpośrednio do tylnej płyty stojaka.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMonitorowanie turbin wytwórczych energii\u003c\/li\u003e\n  \u003cli\u003eOchrona maszyn rafinerii ropy naftowej i gazu\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie obrotowego sprzętu petrochemicznego\u003c\/li\u003e\n  \u003cli\u003ePrzemysłowe systemy sprężarkowe na dużą skalę\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eKod opcji\u003c\/th\u003e\n      \u003cth\u003eGniazdo \/ typ konfiguracji\u003c\/th\u003e\n      \u003cth\u003eParametry napięcia\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e03 (górne gniazdo)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZasilacz wysokiego napięcia DC\u003c\/td\u003e\n      \u003ctd\u003e88 do 140 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e02 (dolne gniazdo)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZasilacz wysokiego napięcia AC\u003c\/td\u003e\n      \u003ctd\u003e175 do 264 Vac rms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e00 (zatwierdzenie agencji)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrak zatwierdzeń agencji\u003c\/td\u003e\n      \u003ctd\u003eWykonanie standardowe\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParametr\u003c\/th\u003e\n      \u003cth\u003eWartość specyfikacji\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3500\/15-03-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp zasilania (górne gniazdo)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWysokie napięcie DC (88 do 140 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp zasilania (dolne gniazdo)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWysokie napięcie AC (175 do 264 Vac rms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZatwierdzenie agencji\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrak (Opcja 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95% bez kondensacji\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymiary (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12,07 cm x 5,08 cm x 25,15 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,39 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLokalizacja stojaka:\u003c\/strong\u003e Moduły zasilające muszą być zainstalowane w lewych gniazdach stojaka Bently Nevada 3500.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIzolacja okablowania:\u003c\/strong\u003e Prowadź przewody wysokiego napięcia AC i wysokiego napięcia DC przez oddzielne, zabezpieczone przewody, aby zapobiec zakłóceniom i zapewnić bezpieczeństwo elektryczne.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUziemienie:\u003c\/strong\u003e Upewnij się, że rama stojaka jest solidnie połączona z uziemieniem ziemnym przed podłączeniem napięcia sieciowego.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668309209451,"sku":"3500\/15-03-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-03-02-00-mphkbt4pjuc_d7798fed-667c-4abd-8cde-5d532142ce9f.jpg?v=1765520788"},{"product_id":"bently-nevada-3500-15-04-00-00-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-04-00-00 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZapewniając stabilne, regulowane zasilanie bezpośrednio do szyny tylnej systemu ochrony maszyn, \u003cstrong\u003eBently Nevada 3500\/15-04-00-00\u003c\/strong\u003e jest niezbędnym modułem zasilania o połowie wysokości. Został zaprojektowany do przyjmowania niskonapięciowego źródła DC i przekształcania go na precyzyjne napięcia wymagane przez inne moduły w szafie 3500. Przeznaczony do niezawodnej pracy ciągłej, ten wariant posiada konfigurację z pojedynczym zasilaniem skonfigurowaną dla górnego gniazda, umożliwiając ekonomiczne rozwiązanie tam, gdzie nie jest wymagana redundantna ścieżka zasilania. Integruje zaawansowane filtrowanie linii i tłumienie przepięć, aby chronić wrażliwe instrumenty diagnostyczne i monitorujące przed anomaliami zasilania w terenie.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNiskonapięciowe wejście DC:\u003c\/strong\u003e Specjalnie skonfigurowane dla zakresu 20 do 30 V DC, idealne dla przemysłowych banków baterii i lokalnych systemów dystrybucji DC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKonfiguracja z pojedynczym zasilaniem:\u003c\/strong\u003e Opcja z aktywnym zasilaczem w górnym gnieździe i pustą konfiguracją w dolnym gnieździe (bez zasilania) w celu minimalizacji zbędnego sprzętu.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostyka wewnętrzna:\u003c\/strong\u003e Ciągłe monitorowanie napięć wyjściowych i statusu systemu, zgłaszanie błędów bezpośrednio do modułu interfejsu szafy (RIM).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZintegrowana ochrona:\u003c\/strong\u003e Wyposażony w solidną ochronę przed przepięciami, przeciążeniem prądowym i zwarciami na wszystkich liniach wyjściowych, chroniąc moduły ochrony maszyn połączone dalej.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiody LED statusu na panelu przednim:\u003c\/strong\u003e Zawiera wskaźniki o wysokiej widoczności do szybkiej weryfikacji statusu „Zasilanie OK” i „Nie OK”.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eSystemy monitorowania drgań i położenia turbin maszynowych.\u003c\/li\u003e\n  \u003cli\u003eCiągły monitoring krytycznych wirujących zasobów w rafineriach ropy i gazu.\u003c\/li\u003e\n  \u003cli\u003eSzafy diagnostyczne turbin parowych i gazowych w elektrowniach.\u003c\/li\u003e\n  \u003cli\u003eCiężkie zakłady przemysłowe wymagające zunifikowanej instrumentacji opierającej się na szafach.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eWartość\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNumer modelu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3500\/15-04-00-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSeria\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTyp zasilacza gniazda górnego\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eNiskonapięciowe DC (20 do 30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTyp zasilacza gniazda dolnego\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBrak zasilania (00)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eZatwierdzenia agencji\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBrak (opcja 00)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eZakres napięcia wejściowego\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e20 do 30 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFormat\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eModuł o połowie wysokości (pasuje do wyznaczonego gniazda po lewej stronie szaf 3500)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStany Zjednoczone (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5,00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eZacisk \/ port\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eFunkcja \/ przypisanie obwodu\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWejście DC (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePołączenie zasilania dodatniego (20 do 30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWejście DC (-)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePołączenie ujemne \/ wspólny powrót\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMasa obudowy\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUziemienie ziemne \/ punkt zakończenia ekranu do przekierowywania szumów wysokoczęstotliwościowych\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpiryczne spostrzeżenia inżynieryjne\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTen moduł zajmuje górną połowę najbardziej lewego gniazda zasilania w szafie 3500. Ponieważ ten konkretny numer części to pojedynczy moduł niskonapięciowy DC (opcja 04) bez drugiego zasilania w dolnym gnieździe (opcja 00), nie może zapewnić pracy redundantnej. Jeśli w przyszłości na miejscu będzie wymagana redundantna zasilanie awaryjne, dolne gniazdo nie może być łatwo doposażone w niepasujący moduł; konieczna będzie wymiana całego zespołu modułu wejściowego zasilania, aby obsługiwał podwójne zasilanie o identycznych parametrach napięciowych.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePodczas stosowania opcji niskonapięciowego DC w gorących środowiskach upewnij się, że szafy obudowy mają aktywną wentylację. Systemy niskonapięciowe o wysokim natężeniu prądu wykazują większe lokalne rozpraszanie ciepła na zaciskach połączeniowych w porównaniu do ich odpowiedników wysokiego napięcia AC. Dodatkowo dolne gniazdo musi być zakryte odpowiednią zaślepką o połowie wysokości, aby zachować zaprojektowane ścieżki konwekcji chłodzenia obudowy i zapobiec przedostawaniu się zakłóceń elektromagnetycznych (EMI).\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAby zapobiec problemom z szumami wspólnego trybu na wysoce czułych sondach zbliżeniowych i kanałach sejsmicznych, prowadź izolowane linie zasilania DC bezpośrednio z regulowanego przemysłowego źródła bateryjnego, zamiast korzystać z linii zasilających współdzielonych z falownikami (VFD) lub ciężkimi stycznikami indukcyjnymi. Używaj przewodu miedzianego o przekroju co najmniej 2,5 mm2 (14 AWG) dla linii wejściowych DC, aby ograniczyć spadek napięcia na dłuższych odcinkach, ponieważ spadek poniżej 20 V DC na zaciskach zasilania szafy spowoduje natychmiastowe zgłoszenie błędu niskiego napięcia.\u003c\/p\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eNigdy nie wkładaj ani nie wyjmuj modułu zasilania lub jego tylnej karty wejściowej, gdy źródło zasilania jest pod napięciem. Łuk elektryczny na złączach modułu zasilania może uszkodzić wewnętrzne elementy półprzewodnikowe i naruszyć integralność szyny systemowej. Przed przystąpieniem do instalacji lub wymiany upewnij się, że nastąpiła całkowita izolacja elektryczna.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.5rem; height: 1.5rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv\u003e\n\u003cstrong style=\"color: #2d3748;\"\u003eMontaż modułu wejściowego zasilania (PIM):\u003c\/strong\u003e Zamocuj tylną kartę PIM solidnie w wyznaczonym gnieździe z tyłu szafy 3500 przed włożeniem przedniego modułu zasilania.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.5rem; height: 1.5rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv\u003e\n\u003cstrong style=\"color: #2d3748;\"\u003eWkładanie modułu przedniego:\u003c\/strong\u003e Wsuń główny moduł zasilania do górnego lewego gniazda o połowie wysokości wzdłuż prowadnic, aż pewnie osadzi się w złączu tylnej płyty. Ręcznie dokręć dwa wbudowane śruby motylkowe.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.5rem; height: 1.5rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv\u003e\n\u003cstrong style=\"color: #2d3748;\"\u003eOkablowanie i ekranowanie:\u003c\/strong\u003e Podłącz linie zasilania 24 V DC do zacisków na tylnej karcie PIM. Upewnij się, że zacisk uziemienia obudowy jest połączony z pojedynczym uziemieniem szafy za pomocą miedzianej taśmy o niskiej impedancji.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.5rem; height: 1.5rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv\u003e\n\u003cstrong style=\"color: #2d3748;\"\u003eZasilanie i testowanie:\u003c\/strong\u003e Włącz główny wyłącznik rozdzielczy prądu stałego. Sprawdź, czy zielona dioda LED „Supply OK” na przednim panelu modułu świeci się i pozostaje stale zapalona, potwierdzając nominalne napięcie zasilania.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310487403,"sku":"3500\/15-04-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-15-04-00-00-nzityv0s1ed_b14bdb42-6319-41d1-b466-7b78f38ad436.jpg?v=1765520835"},{"product_id":"bently-nevada-3500-15-05-00-00-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-05-00-00 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eZaprojketowany do integracji z systemem ochrony maszyn Bently Nevada 3500, \u003cstrong\u003e3500\/15-05-00-00\u003c\/strong\u003e działa jako moduł zasilania o połowie wysokości, który zapewnia niezawodne i regulowane zasilanie do szyny systemowej. Moduł ten akceptuje szeroki zakres napięć wejściowych i przetwarza je na dokładne poziomy wymagane przez inne moduły w szafie, zapewniając ciągłość monitorowania maszyn.\u003c\/p\u003e\n\n\u003cp\u003eKonfiguracja tego konkretnego modelu, oznaczonego przyrostkiem 05-00-00, obejmuje pojedynczy zasilacz uniwersalnego napięcia AC zdolny do pracy w zakresie od 85 do 264 Vac rms. Drugie gniazdo zasilania jest puste (brak zasilania redundantnego), a urządzenie nie posiada zatwierdzeń agencji dla stref zagrożenia, co czyni je bardzo odpowiednim do standardowych, nieklasyfikowanych środowisk przemysłowych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDostarcza regulowane zasilanie DC bezpośrednio do szyny systemu 3500.\u003c\/li\u003e\n  \u003cli\u003eUniwersalna kompatybilność wejścia AC w zakresie od 85 do 264 Vac rms.\u003c\/li\u003e\n  \u003cli\u003eKonstrukcja o połowie wysokości umożliwia kompaktową instalację w obudowie szafy 3500.\u003c\/li\u003e\n  \u003cli\u003eObsługuje operacje z pojedynczym zasilaniem, gdzie nie jest wymagane zasilanie redundantne.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSystemy ochrony maszyn i monitorowania stanu.\u003c\/li\u003e\n  \u003cli\u003eZakłady wytwarzania energii i systemy monitorowania turbin.\u003c\/li\u003e\n  \u003cli\u003eZakłady rafinacji ropy i przetwórstwa petrochemicznego.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie ciężkich maszyn obrotowych przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProducent\u003c\/strong\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumer części \/ model\u003c\/strong\u003e\n      \u003ctd\u003e3500\/15-05-00-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTyp zasilacza\u003c\/strong\u003e\n      \u003ctd\u003eUniwersalne napięcie AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eZakres napięcia wejściowego\u003c\/strong\u003e\n      \u003ctd\u003e85 do 264 Vac rms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOpcja zasilania redundantnego\u003c\/strong\u003e\n      \u003ctd\u003eBrak (konfiguracja z pojedynczym zasilaniem)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eZatwierdzenia agencji\u003c\/strong\u003e\n      \u003ctd\u003eBrak\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWaga netto\u003c\/strong\u003e\n      \u003ctd\u003e1,39 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWaga wysyłkowa\u003c\/strong\u003e\n      \u003ctd\u003e3,00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUpewnij się, że zasilanie główne jest całkowicie wyłączone przed włożeniem lub wyjęciem modułu zasilania.\u003c\/li\u003e\n  \u003cli\u003eMocno zamontuj moduł w dedykowanych lewych gniazdach zasilania w szafie 3500.\u003c\/li\u003e\n  \u003cli\u003eUstanów niskooporowe połączenie uziemiające z obudową szafy, aby zminimalizować zakłócenia elektromagnetyczne.\u003c\/li\u003e\n  \u003cli\u003eProwadź linie zasilania AC oddzielnie od wrażliwych kabli sygnałowych, aby zapobiec sprzężeniu szumów.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668311732587,"sku":"3500\/15-05-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-05-00-00-f3xpvoososs_8f7425c6-ce96-488d-b5d3-1056249cb11a.jpg?v=1765520870"},{"product_id":"bently-nevada-3500-04-01-00-3500-series-internal-barriers-earthing-module","title":"Moduł uziemienia wewnętrznych barier serii Bently Nevada 3500\/04-01-00 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePełniąc rolę dedykowanego punktu odniesienia uziemienia, \u003cstrong\u003eBently Nevada 3500\/04-01-00\u003c\/strong\u003e tworzy bezpieczną i niskooporową ścieżkę do ziemi dla wewnętrznych barier bezpieczeństwa systemu ochrony maszyn serii 3500. Ten specjalistyczny moduł uziemienia jest niezbędny do zachowania integralności konstrukcyjnej i elektrycznej instalacji iskrobezpiecznych. Poprzez bezpieczne kierowanie prądów zwarciowych do uziemienia instrumentów zapobiega powstawaniu niebezpiecznych potencjałów elektrycznych w czujnikach polowych umieszczonych w strefach zagrożonych. Moduł dostarczany jest z zintegrowanym panelem przednim do estetycznego montażu w standardowych ramach szafy 3500.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eZapewnia dedykowany, bezpośredni interfejs uziemienia do podwozia dla zastosowań z barierami wewnętrznymi.\u003c\/li\u003e\n  \u003cli\u003eZawiera fabrycznie zamontowany panel przedni dla integracji konstrukcyjnej i ochrony przed kurzem w szafie 3500.\u003c\/li\u003e\n  \u003cli\u003eUmożliwia zgodny montaż iskrobezpiecznych połączeń czujników polowych.\u003c\/li\u003e\n  \u003cli\u003ePrzeznaczony do pracy w trudnych warunkach przemysłowych z rygorystycznymi wymaganiami dotyczącymi uziemienia o wysokiej integralności.\u003c\/li\u003e\n  \u003cli\u003eZajmuje jedno miejsce, odpowiadając standardowym wymiarom konstrukcyjnym szafy ochronnej maszyn 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eMonitorowanie drgań i położenia turbin maszyn w niebezpiecznych środowiskach chemicznych.\u003c\/li\u003e\n  \u003cli\u003eZakłady petrochemiczne i rafinerie wykorzystujące pętle czujników iskrobezpiecznych.\u003c\/li\u003e\n  \u003cli\u003eZakłady wytwarzania energii wymagające certyfikowanych, niskoszumowych linii uziemiających.\u003c\/li\u003e\n  \u003cli\u003ePlatformy monitorowania maszyn obrotowych działające w atmosferach wybuchowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0; width: 35%;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel \/ numer części\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500\/04-01-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSeria\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTyp modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModuł uziemienia barier wewnętrznych\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDołączone elementy\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eZespół interfejsu panelu przedniego\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eWymiary (W x S x G)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24,1 cm x 2,44 cm x 10,31 cm (9,50 in. x 0,96 in. x 4,06 in.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eWaga netto\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0,201 kg (0,443 lb.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eWaga wysyłkowa\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1,5 kg (3,3 lbs.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eStany Zjednoczone Ameryki (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpiryczne spostrzeżenia inżynieryjne\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eModuł uziemiający 3500\/04-01-00 jest wyraźnie wymagany dla szaf 3500 skonfigurowanych z wewnętrznymi barierami iskrobezpiecznymi. Szafy wykorzystujące standardowe zewnętrzne bariery lub monitory bezbarierowe nie wymagają tego modułu. Przed instalacją upewnij się, że uziemienie obudowy szafy jest kompatybilne z siecią uziemienia przyrządów w twojej instalacji.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eCzęstą usterką w terenie jest podłączenie modułu uziemiającego do hałaśliwego uziemienia bezpieczeństwa elektrycznego (brudne uziemienie) zamiast do dedykowanego, wysokiej integralności uziemienia przyrządu (czyste uziemienie). Prądy pętli uziemienia mogą indukować znaczne zakłócenia wysokiej częstotliwości na ścieżkach sygnałów drgań, powodując fałszywe wyzwolenia awaryjnego zatrzymania maszyny lub błędy przyrządów. Utrzymuj połączenia uziemienia bezpieczeństwa całkowicie odizolowane od uziemienia sieciowego konstrukcji.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePodczas pierwszego uruchomienia sprawdź, czy rezystancja uziemienia między zaciskiem obudowy modułu 3500\/04 a główną szyną uziemiającą przyrządu jest mniejsza niż 1,0 oma. Regularnie kontroluj mechaniczne śruby panelu przedniego, aby upewnić się, że są dokręcone zgodnie ze specyfikacjami producenta, ponieważ poluzowane elementy bezpośrednio pogarszają ścieżkę o niskiej impedancji wymaganą do ochrony iskrobezpiecznej.\u003c\/p\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e Odłącz wszystkie główne i pomocnicze źródła zasilania dostarczające energię do szafy 3500 przed włożeniem lub wyjęciem modułu uziemiającego. Nieprzestrzeganie tego może spowodować łuk elektryczny, potencjalne pogorszenie parametrów bezpieczeństwa iskrobezpiecznego lub nieoczekiwane wyzwolenie awaryjnego zatrzymania maszyny.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWyłącz system 3500 i rozładuj wszelką pozostałą energię z sąsiednich komponentów.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWyrównaj moduł uziemiający z prowadnicami w wyznaczonym slocie szafy 3500.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWsuń moduł mocno do szafy, aż panel przedni zetknie się z ramą obudowy.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eZabezpiecz śruby mocujące panel przedni, aby zapewnić solidny metalowy kontakt uziemiający.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668312027499,"sku":"3500\/04-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-04-01-00-okkuuj04doh_498524d3-61b2-44a1-b308-b056e0ee2241.jpg?v=1765520880"},{"product_id":"bently-nevada-149986-02-3500-series-4-channel-relay-control-module","title":"Moduł sterowania przekaźnikami 4-kanałowy Bently Nevada 149986-02 seria 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eSkonfigurowany do ochrony ciężkich maszyn przemysłowych, \u003cstrong\u003eBently Nevada 149986-02\u003c\/strong\u003e zapewnia niezawodną funkcjonalność sterowania przekaźnikami 4-kanałowymi w architekturze systemu szafki 3500. Moduł ten służy jako kluczowy interfejs do realizacji wyjść alarmowych sprzętowych, wyłączeń systemu i schematów blokad bezpieczeństwa. Przekształcając elektroniczne stany alarmowe w fizyczne wyjścia styków przekaźnikowych, chroni cenne obracające się urządzenia, takie jak turbiny parowe, sprężarki odśrodkowe i duże silniki indukcyjne przed katastrofalnymi trybami awarii.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCztery niezależne kanały:\u003c\/strong\u003e Posiada cztery w pełni programowalne wyjścia przekaźnikowe jednobiegunowe, dwupozycyjne (SPDT), działające niezależnie na podstawie skonfigurowanej logiki alarmowej.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKonfigurowalna logika:\u003c\/strong\u003e Przekaźniki mogą być skonfigurowane do pracy normalnie załączonej (NE) lub normalnie wyłączonej (NDE), aby dopasować się do topologii zakładu bezpiecznej awarii lub bezpiecznej dla procesu.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWykonanie na poziomie sprzętowym:\u003c\/strong\u003e Pomija systemy operacyjne oprogramowania, wykonując polecenia wyzwalania ochronnego bezpośrednio przez twardo okablowane ścieżki przekaźnikowe, minimalizując czas reakcji.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWbudowane wsparcie redundancji:\u003c\/strong\u003e Łatwo integruje się z konfiguracjami podwójnej lub potrójnej modularnej redundancji (TMR) w systemach bezpieczeństwa (np. logika 2 z 3).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWskaźniki LED w czasie rzeczywistym:\u003c\/strong\u003e Diody LED na przednim panelu zapewniają szybkie wizualne diagnozowanie aktywnych stanów alarmowych i usterek systemu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystemy wyłączania turbin:\u003c\/strong\u003e Bezpośrednia integracja z obwodami awaryjnego wyłączania (ESD) turbin gazowych, parowych i wodnych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo stacji sprężarek:\u003c\/strong\u003e Automatyzuje zawory izolacyjne i odpowietrzające podczas przepływów udarowych lub wysokich drgań.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOchrona instalacji pomocniczej:\u003c\/strong\u003e Chroni wentylatory chłodzące, duże pompy wodne i przekładnie, wyzwalając lokalne sygnalizatory lub alerty DCS.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlokada awaryjna:\u003c\/strong\u003e Blokuje wyłączniki generatora z mechanicznymi warunkami wyzwalania, aby zapobiec uszkodzeniom od mocy zwrotnej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eWartość specyfikacji\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNumer części\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e149986-02\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTyp modułu\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eZapasowy moduł sterowania przekaźnikami 4-kanałowymi\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eKompatybilny system\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem ochrony maszyn Bently Nevada serii 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTyp styku przekaźnika\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePrzełącznik jednobiegunowy, dwupozycyjny (SPDT) \/ Forma C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePrąd znamionowy styku\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5 A przy 120 Vac \/ 240 Vac (rezystancyjne), 5 A przy 24 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTemperatura pracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-30 do +65 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTemperatura przechowywania\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-40 do +85 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWilgotność względna\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e95% bez kondensacji\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWymiary opakowania\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2,5 cm x 25,8 cm x 12,0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWaga netto\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.740kg;\"\u003e0,74 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2,00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eStany Zjednoczone (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpiryczne spostrzeżenia inżynierskie\u003c\/h3\u003e\n\u003ch4\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e149986-02 to główny zespół płyty obwodów dla standardowego 4-kanałowego modułu przekaźnikowego Bently Nevada 3500\/32. Należy zauważyć, że jest on funkcjonalnie odmienny od 16-kanałowego modułu przekaźnikowego 3500\/33. Upewnij się, że oprogramowanie konfiguracyjne szafy 3500 obsługuje konkretną rewizję płyty, aby uniknąć błędów niezgodności konfiguracji podczas integracji.\u003c\/p\u003e\n\n\u003ch4\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePodczas przełączania silnie indukcyjnych obciążeń AC lub DC (takich jak ciężkie zawory elektromagnetyczne lub cewki głównego wyłącznika), zainstaluj zewnętrzne obwody tłumiące lub diody tłumiące bezpośrednio na obciążeniu. Przełączanie nie tłumionych obciążeń indukcyjnych spowoduje nadmierne łukowanie styków, znacznie skracając żywotność wewnętrznych styków przekaźnika i potencjalnie wywołując zakłócenia elektromagnetyczne (EMI) w szynie tylnej szafy 3500.\u003c\/p\u003e\n\n\u003ch4\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUstawienia zworek sprzętowych na płycie 149986-02 określają, czy przekaźniki są normalnie załączone (NE) czy normalnie wyłączone (NDE). Upewnij się, że te ustawienia sprzętowe dokładnie odpowiadają konfiguracji w bazie danych oprogramowania. Niezgodność spowoduje błąd konfiguracji i uniemożliwi przejście szafy do trybu „Run”.\u003c\/p\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e Przed włożeniem lub wyjęciem modułu upewnij się, że wszystkie zewnętrzne połączenia źródeł wysokiego napięcia prowadzące do zacisków przekaźnika są odizolowane, zablokowane i oznakowane. Nieodłączenie zewnętrznych obwodów polowych może spowodować niszczące łukowanie elektryczne i stanowi poważne zagrożenie porażeniem dla personelu.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eZałóż opaskę antystatyczną na nadgarstek podłączoną do zweryfikowanego punktu uziemienia przed wyjęciem modułu z opakowania antystatycznego.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eSprawdź złącze krawędziowe karty pod kątem kurzu, zanieczyszczeń lub zabrudzenia powłoką złotą przed instalacją.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eWyrównaj kartę modułu wzdłuż prowadnic karty w wyznaczonym slocie w podwoziu 3500, wsuwając ją do tyłu, aż pewnie osadzi się w złączu tylnej płyty.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eDokładnie dokręć dwa śruby mocujące podwozie na przednim panelu, aby zabezpieczyć moduł i zapewnić optymalne uziemienie ramy.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668312355179,"sku":"149986-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/149986-02-4ffdbpfp1vp_ee025e28-9a7e-471f-823f-7d34013bb55c.jpg?v=1765520891"},{"product_id":"bently-nevada-3500-15-04-04-00-3500-series-power-supply-module","title":"Moduł zasilania Bently Nevada 3500\/15-04-04-00 serii 3500","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZapewnia czyste, wysoce stabilne zasilanie elektryczne dla szafy systemu ochrony maszyn 3500. \u003cstrong\u003eBently Nevada 3500\/15-04-04-00\u003c\/strong\u003e działa jako moduł zasilania niskonapięciowego o wysokiej niezawodności. Moduł przyjmuje niskonapięciowe wejścia DC i przekształca podstawowe zasilanie na regulowane napięcia wymagane przez moduły monitorujące i komunikacyjne w szafie. Obsługuje konfigurację zasilania z podwójną redundancją, maksymalizując dostępność systemu w ciężkich zakładach przemysłowych, rafineriach ropy naftowej i elektrowniach, gdzie ciągły monitoring zasobów jest kluczowy.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundantne wsparcie zasilania:\u003c\/strong\u003e Obsługuje podstawowe i zapasowe zasilanie niskonapięciowe DC, zapewniając nieprzerwaną pracę systemu podczas awarii pojedynczego źródła zasilania.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZintegrowana diagnostyka:\u003c\/strong\u003e Diody LED na panelu przednim wskazują stan „Zasilanie OK” oraz „Przegrzanie” dla natychmiastowej diagnostyki w terenie.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIzolacja przejściowa:\u003c\/strong\u003e Wbudowane filtry wewnętrzne izolują wrażliwe komponenty szafy od zakłóceń elektromagnetycznych (EMI) i zewnętrznych przepięć linii.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSolidna architektura bezpieczeństwa:\u003c\/strong\u003e Wyposażony w automatyczne mechanizmy wyłączania przy przeciążeniu prądowym i przepięciu, chroniące zainstalowane moduły monitorujące.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSieci monitorowania drgań turbin, generatorów i sprężarek.\u003c\/li\u003e\n  \u003cli\u003eSzafy ochrony maszyn w zakładach petrochemicznych i naftowych.\u003c\/li\u003e\n  \u003cli\u003eKrytyczne wirujące maszyny pomocnicze zakładu.\u003c\/li\u003e\n  \u003cli\u003eSystemy turbin parowych i gazowych do wytwarzania energii.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTabela specyfikacji technicznych\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParametr\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eWartość specyfikacji\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProducent\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSeria modelowa\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNumer części\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3500\/15-04-04-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOpcja zasilania podstawowego\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNiskie napięcie DC (20 do 30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOpcja zasilania awaryjnego\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNiskie napięcie DC (20 do 30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eZakres napięcia wejściowego\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e20 do 30 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eZatwierdzenia agencji\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBrak (opcja 00)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eKraj pochodzenia\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUSA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eWaga netto\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1,39 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eWaga wysyłkowa (obliczona)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2,50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpiryczne spostrzeżenia inżynieryjne\u003c\/h3\u003e\n\u003ch4\u003eModele alternatywne i kompatybilność\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eModel 3500\/15-04-04-00 to konfiguracja wyłącznie niskonapięciowego DC. Przy wymianie starszych jednostek 3500\/15 upewnij się, że blok zacisków zasilania backplane szafy jest zaprojektowany specjalnie do nominalnego zasilania 24 Vdc. Instalacja modułu DC w szafie fabrycznie okablowanej pod wysokie napięcie AC (np. opcje 3500\/15-01-xx) uszkodzi wewnętrzne piny zacisków. Przy migracji z konfiguracji starszych sprawdź fizyczne prześwity prowadnic kart w chassis wczesnych rewizji 3500.\u003c\/p\u003e\n\n\u003ch4\u003ePułapki aplikacyjne i uwagi inżynierskie\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePrzy pełnym obciążeniu szafy (wszystkie 14 slotów monitorujących z podwójnymi przekaźnikami lub kartami sejsmicznymi o dużym poborze prądu) wzrasta rozpraszanie ciepła w modułach zasilania. Zachowaj wolną drogę wentylacyjną nad i pod obudową 3500. Unikaj łączenia zasilania niskonapięciowego DC i wysokiego napięcia AC w tym samym chassis, chyba że backplane szafy został wyraźnie zweryfikowany pod kątem układów zasilania mieszanych napięć, ponieważ w przypadku awarii może dojść do braku przełączenia przy niezgodnych impedancjach zasilania.\u003c\/p\u003e\n\n\u003ch4\u003eWskazówki dotyczące uruchomienia i okablowania\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eZawsze używaj ekranowanych kabli skrętkowych (minimum 12 AWG) do zacisków wejściowych DC, aby chronić backplane przed zakłóceniami wspólnego trybu. Upewnij się, że zacisk uziemienia ramy na bloku wejściowym jest połączony z czystym uziemieniem instrumentu niskooporowym połączeniem. Zapobiega to pętlom uziemienia, które mogłyby zakłócać sygnały monitorowania przejściowego przechodzące przez sąsiednie karty monitorujące.\u003c\/p\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eOSTRZEŻENIE KRYTYCZNE:\u003c\/strong\u003e Odłącz zasilanie wszystkich zewnętrznych źródeł prądu stałego pierwotnego i wtórnego przed próbą wsunięcia modułu zasilania do slotu w szafie. Niepełna izolacja linii zasilających może spowodować niebezpieczne łukowanie elektryczne, prowadzące do fizycznego uszkodzenia styków backplane i nieoczekiwanych restartów szafy.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eIzoluj i sprawdź, czy linie zasilania niskiego napięcia DC mają napięcie poniżej 2 Vdc przed podłączeniem przewodów do tylnych bloków zaciskowych.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eWsuń moduł wzdłuż prowadnic karty chassis w wyznaczonym slocie (zazwyczaj skrajnie po lewej stronie szafy 3500), aż złącza zostaną mocno osadzone.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eZabezpiecz śruby zintegrowanego panelu modułu do ramy chassis, aby zapewnić solidne uziemienie i montaż odporny na wibracje.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eWłącz zasilanie źródła DC i sprawdź, czy zielona dioda „OK” na przednim panelu świeci się stabilnie.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668312420715,"sku":"3500\/15-04-04-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-15-04-04-00-qgfqcvyhad1_bd2b8efa-9cbe-4e55-af66-6eb3d51e9690.jpg?v=1765520894"},{"product_id":"bently-nevada-3500-15-07-00-00-low-voltage-dc-power-supply-module","title":"Moduł zasilania niskiego napięcia DC Bently Nevada 3500\/15-07-00-00","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eModel \u003cstrong\u003e3500\/15-07-00-00\u003c\/strong\u003e działa jako instrument regulacyjny o połowie wysokości, zaprojektowany do konwersji prądu stałego na kontrolowane linie napięciowe dla komponentów dalszego stopnia w \u003cstrong\u003eSystemie Ochrony Maszyn Serii 3500\u003c\/strong\u003e. Umieszczony w wyznaczonych lewych slotach standardowej obudowy rack, ten specyficzny niskonapięciowy układ prądu stałego zapewnia niezawodne monitorowanie stanu maszyn poprzez architekturę wspierającą redundancję pojedynczego i podwójnego zasilania. Instrument zapobiega całkowitemu przerwaniu procesu podczas nagłych spadków głównego zasilania i łączy się bezpośrednio z dedykowanym modułem wejścia zasilania niskonapięciowego prądu stałego (PIM), aby współpracować z liniami dystrybucji w złożonych zakładach automatyki przemysłowej.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProfil fizyczny o połowie wysokości wspierający podwójne redundantne konfiguracje zasilania w jednym chassis monitorującym.\u003c\/li\u003e\n\u003cli\u003ePełne zasilanie magistrali instrumentacyjnej zdolne do obsługi w pełni zajętego stojaka monitorującego z pojedynczego modułu.\u003c\/li\u003e\n\u003cli\u003eProjekt umożliwiający wymianę modułów na gorąco bez przerywania ochrony podczas pracy, pod warunkiem, że równoległe redundantne zasilanie pozostaje aktywne.\u003c\/li\u003e\n\u003cli\u003eWizualny monitoring na panelu przednim za pomocą dedykowanej diody LED statusu Supply OK wskazującej stabilne pętle regulacji.\u003c\/li\u003e\n\u003cli\u003eZintegrowane sieci ochrony przed przepięciami i niedociśnieniami zaprojektowane w celu zabezpieczenia wewnętrznych komponentów podczas przejściowych zmian napięcia zasilania.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCiągłe sieci ochrony maszyn w elektrowniach, przemyśle naftowym i petrochemicznym.\u003c\/li\u003e\n\u003cli\u003eDystrybucja zasilania niskonapięciowego prądu stałego z baterii do monitorowania turbin maszynowych.\u003c\/li\u003e\n\u003cli\u003eRedundantne konfiguracje infrastruktury w obszarach zagrożonych procesami przemysłowymi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZasilacze prądu przemiennego i stałego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 07\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZasilacz niskonapięciowy prądu stałego (20 do 30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrak zasilania (używane, gdy wymagane jest tylko jedno zasilanie)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpcja zatwierdzenia agencji: Brak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje Techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKategoria\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDane\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElektryczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZakres napięcia wejściowego\u003c\/td\u003e\n\u003ctd\u003eZakres napięcia wejściowego 20 do 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePobór prądu wejściowego\u003c\/td\u003e\n\u003ctd\u003eMaksymalny prąd wejściowy 10,0 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRedundantne Wyrównanie\u003c\/td\u003e\n\u003ctd\u003eDolny slot w szafie oznacza źródło podstawowe; górny slot obsługuje przejęcie zapasowe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eŚrodowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZakres temperatury pracy\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eZakres temperatury przechowywania\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eZakres wilgotności względnej\u003c\/td\u003e\n\u003ctd\u003eMaksymalna wilgotność względna 95% bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechaniczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWymiary Modułu Zasilania (W x S x G)\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 50,8 mm x 251,5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWaga Modułu Zasilania\u003c\/td\u003e\n\u003ctd\u003e1,39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWymiary Modułu Zasilania Wejściowego (W x S x G)\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 25,4 mm x 114,3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWaga Modułu Zasilania Wejściowego\u003c\/td\u003e\n\u003ctd\u003e0,34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDedykowany Przydział Slotów\u003c\/td\u003e\n\u003ctd\u003eWymaga pozycji o połowie wysokości w lewej części szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne Instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrzydział Slotów w Szafie:\u003c\/strong\u003e Wsuń główny moduł zasilania wyłącznie do wyznaczonych przednich slotów o połowie wysokości, po lewej stronie szafy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguracja Faz Redundancji:\u003c\/strong\u003e W przypadku podwójnego zasilania redundantnego, umieść główny moduł niskiego napięcia na dolnej pozycji, a zapasowy moduł w górnej, o połowie wysokości.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWyrównanie Modułu Tylnego:\u003c\/strong\u003e Podłącz przewody zasilające bezpośrednio do odpowiadającego modułu zasilania niskiego napięcia prądu stałego umieszczonego z tyłu szafy, bezpośrednio za przednią kartą zasilania.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i Certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywy EMC:\u003c\/strong\u003e 2014\/30\/EU; EN 61000-6-2 (Odporność na zakłócenia w środowiskach przemysłowych), EN 61000-6-4 (Emisje w środowiskach przemysłowych).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo Niskiego Napięcia:\u003c\/strong\u003e 2014\/35\/EU; EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikacja Morska:\u003c\/strong\u003e Zasady DNV GL dotyczące klasyfikacji statków i jednostek offshore; zasady ABS dotyczące stanu klasyfikacji.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668315435371,"sku":"3500\/15-07-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-07-00-00-tnw5zjowage_4ad98092-fdf1-4e98-8d7a-dda7aeff80fa.jpg?v=1765520999"},{"product_id":"bently-nevada-3500-15-05-05-cn-3500-15-dual-channel-power-supply-module","title":"Moduł zasilania dwukanałowego Bently Nevada 3500\/15-05-05-CN 3500\/15","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/15-05-05-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto moduł zasilania do racków serii 3500, zaprojektowany do dostarczania regulowanego i niezawodnego zasilania elektrycznego dla systemów ochrony maszyn Bently Nevada 3500. Jest szeroko stosowany w elektrowniach, zakładach naftowych i gazowych oraz ciężkich jednostkach przetwórczych, gdzie ciągły monitoring stanu zależy od stabilnego zasilania na poziomie racka.\u003c\/p\u003e\n\u003cp\u003eTen moduł obsługuje uniwersalne wejście AC oraz konfigurację redundancji z dwoma slotami, zapewniając nieprzerwaną pracę krytycznych systemów monitoringu. Konstrukcja umożliwia jednoczesną instalację dwóch zasilaczy dla redundancji, zmniejszając ryzyko zatrzymania systemu z powodu awarii pojedynczego zasilacza.\u003c\/p\u003e\n\u003cp\u003eKonfiguracja CN wskazuje na wymagania dotyczące zgodności z przepisami dotyczącymi stref zagrożenia specyficznych dla kraju w regulowanych środowiskach przemysłowych.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eStruktura konfiguracji zasilania\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOpis\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500\/15\u003c\/td\u003e\n\u003ctd\u003eModuł zasilania serii 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eUniwersalne wejście AC 85 do 264 Vac rms (górny slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eUniwersalne wejście AC 85 do 264 Vac rms (dolny slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eZatwierdzenia specyficzne dla kraju\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTa konfiguracja definiuje kompatybilność wejścia i architekturę redundancji dla dystrybucji zasilania w racku.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParametr\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/15-05-05-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarka\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePochodzenie\u003c\/td\u003e\n\u003ctd\u003eStany Zjednoczone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary\u003c\/td\u003e\n\u003ctd\u003e25,15 cm x 5,08 cm x 12,07 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga\u003c\/td\u003e\n\u003ctd\u003eNieokreślona (typowy moduł rackowy około 2–3 kg na poziomie systemu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga wysyłkowa\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNapięcie wejściowe\u003c\/td\u003e\n\u003ctd\u003e85 do 264 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWilgotność\u003c\/td\u003e\n\u003ctd\u003e95 procent bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eSystem ochrony maszyn 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCzy to zasilanie jest redundantne?\u003c\/strong\u003e\u003cbr\u003eTak. Model 3500\/15 obsługuje konfigurację podwójnego zasilania dla redundancji.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy może działać na globalnych standardach napięcia?\u003c\/strong\u003e\u003cbr\u003eTak. Obsługuje uniwersalne wejście AC od 85 do 264 Vac.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo się stanie, jeśli jeden moduł zasilania ulegnie awarii?\u003c\/strong\u003e\u003cbr\u003eSystem kontynuuje pracę, korzystając z pozostałego aktywnego zasilacza.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy jest kompatybilny ze wszystkimi rackami 3500?\u003c\/strong\u003e\u003cbr\u003eJest kompatybilny ze standardowymi systemami rack Bently Nevada 3500.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eUwagi inżynieryjne i instalacyjne\u003c\/h3\u003e\n\u003cp\u003eZainstaluj oba zasilacze w konfiguracji podwójnej, gdy czas pracy systemu jest krytyczny.\u003c\/p\u003e\n\u003cp\u003eZapewnij prawidłowe uziemienie racka, aby zmniejszyć zakłócenia elektryczne i poprawić stabilność systemu.\u003c\/p\u003e\n\u003cp\u003eSprawdź odstęp przepływu powietrza, aby utrzymać stabilność termiczną przy dużym obciążeniu.\u003c\/p\u003e\n\u003cp\u003eNie mieszaj niekompatybilnych rewizji modułów zasilania w tym samym racku.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWytyczne inżynieryjne dotyczące eksploatacji\u003c\/h3\u003e\n\u003cp\u003eStosuj redundantną konfigurację zasilania w systemach ochrony turbin i monitoringu sprężarek.\u003c\/p\u003e\n\u003cp\u003eUtrzymuj stabilne warunki środowiskowe, aby wydłużyć żywotność modułu.\u003c\/p\u003e\n\u003cp\u003eSprawdzaj złącza podczas zaplanowanych cykli konserwacji, aby zapobiec przerywanemu zanikowi zasilania.\u003c\/p\u003e\n\u003cp\u003eZapewnij prawidłowe umieszczenie slotu, aby uniknąć niezgodności konfiguracji w systemach rack.\u003c\/p\u003e\n\u003ch1\u003e\u003c\/h1\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318712171,"sku":"3500\/15-05-05-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-05-05-cn-tq34mqb1fs4_b60a0308-d0e3-4021-897f-fc7c07e1ae3d.jpg?v=1765521114"},{"product_id":"bently-nevada-3500-15-05-05-00-universal-ac-power-supply-module","title":"Moduł zasilania uniwersalnego prądu przemiennego Bently Nevada 3500\/15-05-05-00","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e\u003c\/span\u003e to moduł zasilania o wysokiej dostępności i półwysokości, zaprojektowany do dostarczania regulowanego zasilania DC dla systemu ochrony maszyn Bently Nevada 3500. Konfiguracja \u003cspan\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e\u003c\/span\u003e została specjalnie opracowana do podwójnie redundantnych układów zasilania, wykorzystując dwa uniwersalne wejścia AC, aby zapewnić ciągłość działania systemu monitorowania nawet w przypadku awarii jednego źródła zasilania. W krytycznych sektorach przemysłowych, takich jak rafinacja ropy, wiercenia morskie i wytwarzanie energii cieplnej, system 3500 stanowi ostatnią linię obrony dla wielomilionowych aktywów obrotowych. Ten moduł zasilania jest fundamentem tej obrony; oferując doskonałą ochronę przed przepięciami i regulację napięcia, eliminuje ryzyko przerw w monitoringu spowodowanych przez przejściowe zakłócenia elektryczne, zapobiegając kosztownym, nieplanowanym przestojom i zapewniając ciągły przepływ danych o stanie mechanicznym.\u003c\/p\u003e\n\u003ch3\u003eRozbicie sufiksu\u003c\/h3\u003e\n\u003cp\u003eKod modelu \u003cspan\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e\u003c\/span\u003e określa profil sprzętowy z podwójnym wejściem AC dla maksymalnej dostępności systemu:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/15:\u003c\/strong\u003e Podstawowa seria zasilaczy dla systemu ochrony maszyn 3500.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Dolne zasilanie):\u003c\/strong\u003e Skonfigurowane na uniwersalne napięcie AC, akceptujące 85 do 264 VAC rms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Górne zasilanie):\u003c\/strong\u003e Drugorzędne zasilanie również skonfigurowane na uniwersalne napięcie AC (85 do 264 VAC rms) dla pracy redundantnej.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Zatwierdzenie agencji):\u003c\/strong\u003e Wersja standardowa bez specyficznych certyfikatów do stref zagrożonych wybuchem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/15-05-05-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNapięcie wejściowe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 do 264 VAC rms (Uniwersalne AC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCzęstotliwość wejściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 do 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25,15 cm x 5,08 cm x 12,07 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 do +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWydajność systemu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZasilanie pełnego stojaka 3500 wraz ze wszystkimi monitorami\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga netto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,39 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania dotyczące integracji systemu\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł obsługuje hot-swap w działającym stojaku?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak. \u003cspan\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e\u003c\/span\u003e jest zaprojektowany do środowisk o wysokiej dostępności. Jeśli masz konfigurację redundantnego zasilania, możesz wyjąć i wymienić jeden moduł zasilania, podczas gdy drugi nadal zasila stojak, zapewniając brak utraty ochrony podczas konserwacji.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy mogę mieszać zasilacze AC i DC w tym samym stojaku?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStojak 3500 obsługuje zarówno opcje AC, jak i DC, ale konkretny sufiks \u003cspan\u003e\u003cstrong\u003e-05-05\u003c\/strong\u003e\u003c\/span\u003e wskazuje, że oba gniazda są zajęte modułami uniwersalnego AC. Jeśli twoje zakłady wymagają hybrydy AC\/DC dla różnych sieci zasilających, potrzebna będzie inna konfiguracja sufiksu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo oznacza oznaczenie \"Uniwersalne\" dla napięcia AC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOznaczenie \"Uniwersalne\" oznacza, że moduł automatycznie dostosowuje się do dowolnego napięcia wejściowego w zakresie od 85 do 264 VAC. Eliminuje to konieczność ręcznego ustawiania zworek lub przełączników podczas wdrażania systemu w różnych regionach świata o różnych standardach zasilania.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik inżynieryjny i instalacyjny\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancja i źródła zasilania\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAby osiągnąć prawdziwą redundancję systemu z \u003cspan\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e\u003c\/span\u003e, każde wejście zasilania powinno być podłączone do fizycznie oddzielnego źródła zasilania (np. Źródło A z głównej sieci i Źródło B z zasilacza awaryjnego\/UPS). Zapobiega to wyłączeniu całego systemu ochrony maszyn w wyniku zadziałania pojedynczego wyłącznika obwodu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZarządzanie termiczne w obudowach\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZasilacz 3500 generuje ciepło podczas procesu konwersji. Podczas instalacji stojaka w szczelnej obudowie NEMA 4 lub IP66, oblicz całkowite obciążenie cieplne, aby zapewnić, że temperatura wewnątrz szafy nie przekroczy 65 °C. Zachowaj co najmniej 2,5 cm odstępu wokół otworów wentylacyjnych stojaka, aby umożliwić naturalną konwekcję.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOchrona wejścia i bezpieczeństwo bezpieczników\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZawsze upewnij się, że zewnętrzne linie zasilające są wyposażone w odpowiednie urządzenia ochrony przeciwprzepięciowej (SPD). Chociaż \u003cspan\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003c\/span\u003e zawiera ochronę wewnętrzną, zewnętrzne przepięcia w ciężkich warunkach przemysłowych mogą przekraczać te limity. Przed wyjęciem modułu sprawdź, czy przełącznik zasilania na panelu przednim jest w pozycji \"Wyłącz\", aby zapobiec iskrzeniu na złączach tylnej płyty.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319334763,"sku":"3500\/15-05-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-05-05-00-sukrnaw2i2w_0a650184-e394-4908-9e4e-34f2ccd47402.jpg?v=1765521139"},{"product_id":"bently-nevada-135489-02-i-o-module-with-internal-barriers-for-prox-accel-and-velomitor-signals","title":"Moduł I\/O Bently Nevada 135489-02 z wewnętrznymi barierami dla sygnałów Prox\/Accel i Velomitor","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e135489-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto moduł I\/O Bently Nevada zaprojektowany do bezpiecznego pozyskiwania sygnałów z czujników zbliżeniowych, przyspieszenia i prędkości w przemysłowych systemach monitorowania drgań. Integruje wewnętrzne bariery i zakończenia, co upraszcza architekturę okablowania, jednocześnie zachowując zgodność z wymogami bezpieczeństwa iskrobezpieczeństwa w instalacjach w strefach zagrożenia wybuchem. Moduł jest powszechnie stosowany w systemach ochrony turbin, sprężarek oraz krytycznych maszyn wirujących, gdzie wymagana jest niezawodna wielokanałowa analiza drgań do ciągłego monitorowania stanu.\u003c\/p\u003e\n\u003cp\u003eTen moduł I\/O obsługuje 2 kanały zbliżeniowe lub akcelerometryczne oraz 2 kanały Velomitor, umożliwiając konfiguracje mieszane czujników w jednym module. Jest szeroko wykorzystywany w zakładach naftowych i gazowych, elektrowniach oraz zakładach petrochemicznych, gdzie niezawodność systemu i zmniejszenie złożoności okablowania bezpośrednio wpływają na efektywność konserwacji i kontrolę przestojów.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 kanały Prox\/Accel do monitorowania drgań wału i przemieszczeń\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 kanały Velomitor do pomiaru prędkości drgań obudowy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWewnętrzne bariery do izolacji sygnałów zgodnej z iskrobezpieczeństwem\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWewnętrzne zakończenia upraszczające okablowanie szafy i zmniejszające złożoność instalacji\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWewnętrzna konstrukcja barier eliminuje potrzebę stosowania zewnętrznych izolatorów, co zmniejsza wymagania dotyczące przestrzeni w szafie i poprawia efektywność integracji systemu. Moduł zapewnia stabilne kondycjonowanie sygnału między czujnikami polowymi a systemami monitoringu, jednocześnie utrzymując ochronę elektryczną w środowiskach zagrożonych wybuchem.\u003c\/p\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParametr\u003c\/th\u003e\n\u003cth class=\"\"\u003eSzczegóły\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e135489-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarka\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp produktu\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z wewnętrznymi barierami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePochodzenie\u003c\/td\u003e\n\u003ctd\u003eWyprodukowano w USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKanały wejściowe\u003c\/td\u003e\n\u003ctd\u003e2 Prox\/Accel + 2 Velomitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp sygnału\u003c\/td\u003e\n\u003ctd\u003eWejścia drgań przemieszczenia i prędkości\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunkcja bezpieczeństwa\u003c\/td\u003e\n\u003ctd\u003eWewnętrzne bariery iskrobezpieczeństwa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakończenie\u003c\/td\u003e\n\u003ctd\u003eWewnętrzne zakończenie sygnału\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZastosowanie\u003c\/td\u003e\n\u003ctd\u003eMonitorowanie turbin, sprężarek, pomp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eŚrodowisko pracy\u003c\/td\u003e\n\u003ctd\u003ePrzemysłowe strefy zagrożenia wybuchem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZużycie energii\u003c\/td\u003e\n\u003ctd\u003eZasilanie z szafy systemowej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga\u003c\/td\u003e\n\u003ctd\u003e0,201 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga wysyłkowa\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp instalacji\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O montowany w szynie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł może obsługiwać jednocześnie sygnały z czujników zbliżeniowych i prędkości?\u003c\/strong\u003e\u003cbr\u003eTak. Obsługuje 2 wejścia zbliżeniowe lub akcelerometryczne oraz 2 kanały prędkości Velomitor równocześnie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy moduł wymaga zewnętrznych barier sygnałowych?\u003c\/strong\u003e\u003cbr\u003eNie. Posiada wewnętrzne bariery, co zmniejsza ilość okablowania zewnętrznego i złożoność szafy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy jest kompatybilny z systemami monitoringu 3500?\u003c\/strong\u003e\u003cbr\u003eTak. Został zaprojektowany do integracji z architekturą systemów monitoringu Bently Nevada serii 3500.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo się stanie w przypadku awarii kanału?\u003c\/strong\u003e\u003cbr\u003eAwaria kanału wywoła alert diagnostyczny w systemie monitoringu, nie wpływając na pozostałe kanały.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstrukcja inżynieryjna i instalacyjna\u003c\/h3\u003e\n\u003cp\u003eZainstaluj moduł w odpowiednio uziemionej obudowie szafy, aby zachować integralność sygnału i zgodność z wymogami iskrobezpieczeństwa. Słabe uziemienie może wprowadzać szumy pomiarowe na wszystkich kanałach.\u003c\/p\u003e\n\u003cp\u003eOddziel okablowanie polowe od linii wysokiego napięcia i kabli VFD, aby uniknąć zakłóceń elektromagnetycznych, szczególnie w szafach sterowania turbin.\u003c\/p\u003e\n\u003cp\u003ePodczas uruchomienia zweryfikuj poprawną konfigurację kanałów. Nieprawidłowo skonfigurowane typy wejść (Prox\/Accel vs Velomitor) mogą prowadzić do błędnej interpretacji drgań.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321890667,"sku":"135489-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-02-i-o-module-with-internal-barriers-and-internal-terminations-ph4wmoxwykw_33e1082e-42c4-4eda-8942-5a692bc45121.jpg?v=1765449578"},{"product_id":"bently-nevada-3500-32-01-00-3500-32m-4-channel-relay-module","title":"Moduł przekaźnikowy Bently Nevada 3500\/32-01-00 3500\/32M 4-kanałowy","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eModuł \u003cstrong\u003e3500\/32-01-00\u003c\/strong\u003e to wysokiej niezawodności, pełnowysokościowy 4-kanałowy moduł przekaźnikowy zaprojektowany dla systemu ochrony maszyn Bently Nevada 3500. W krytycznych środowiskach przemysłowych, takich jak rafinerie ropy naftowej, terminale LNG i elektrownie cieplne, moduł ten pełni rolę głównego fizycznego interfejsu do automatycznego wyłączania maszyn i powiadamiania alarmowego. \u003cstrong\u003e3500\/32-01-00\u003c\/strong\u003e umożliwia złożoną, niezależną logikę głosowania na czterech wyjściach przekaźnikowych, wykorzystując konfiguracje AND\/OR do przetwarzania statusów Alert, Danger i Not-OK z innych modułów monitorujących w szafie. Przekształcając cyfrową logikę sterowania alarmem na działania mechaniczne przekaźników, zapewnia mechanizm bezpieczny na wypadek awarii, chroniąc kosztowne wirujące urządzenia przed katastrofalnymi uszkodzeniami, znacznie zmniejszając skutki finansowe nieplanowanych przestojów i zapewniając zgodność z wymogami bezpieczeństwa na terenie zakładu.\u003c\/p\u003e\n\u003ch3\u003eRozbicie sufiksu\u003c\/h3\u003e\n\u003cp\u003eKod modelu \u003cstrong\u003e3500\/32-01-00\u003c\/strong\u003e wskazuje następujące specyfikacje sprzętowe i regulacyjne:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/32:\u003c\/strong\u003e Podstawowa seria modułu przekaźnikowego 4-kanałowego.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01 (Moduł wyjściowy):\u003c\/strong\u003e Określa obecność 4-kanałowego modułu I\/O przekaźnikowego, który zapewnia fizyczne punkty połączeń dla zewnętrznych obwodów alarmowych i wyłączających.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00 (Zatwierdzenie agencji):\u003c\/strong\u003e Wersja standardowa bez specyficznych zatwierdzeń agencji dla stref zagrożenia wybuchem, odpowiednia do instalacji w nieklasyfikowanych, ogólnego przeznaczenia pomieszczeniach sterowniczych przemysłowych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSzczegóły specyfikacji\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/32-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp przekaźnika\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePrzełącznik jednobiegunowy, dwupozycyjny (SPDT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eŻywotność styków\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 000 cykli przy 5 A, 24 VDC lub 240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypowo 5,8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 do +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241 mm x 24,4 mm x 242 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga netto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,7 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUszczelnienie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePrzekaźniki uszczelnione epoksydowo z tłumikami łuku 250 Vrms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformacje o komponencie i FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGdzie można umieścić ten moduł w szafie 3500?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł \u003cstrong\u003e3500\/32-01-00\u003c\/strong\u003e można zainstalować w dowolnym dostępnym slocie po prawej stronie modułu Transient Data Interface (TDI). Ponieważ szafa komunikuje się cyfrowo przez płytę tylnią, można dodać dowolną liczbę modułów przekaźnikowych, aby spełnić wymagania logiki głosowania i awaryjnego wyłączania w zakładzie.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy mogę skonfigurować przekaźniki tak, aby były załączone podczas normalnej pracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak. Każdy z czterech kanałów jest wybierany przełącznikiem. Można je zaprogramować jako „Normalnie wyłączone” (przekaźniki zamykają się przy alarmie) lub „Normalnie załączone” (przekaźniki otwierają się przy alarmie lub utracie zasilania). Ta druga opcja jest często preferowana dla bezpiecznych obwodów „Trip”.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak sprawdzić, czy konkretny kanał jest w stanie alarmu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNa przednim panelu modułu znajdują się dedykowane diody LED CH ALARM dla każdego kanału. Dodatkowo dioda TX\/RX miga, potwierdzając aktywną komunikację z płytą tylnią szafy, a dioda OK wskazuje, że wewnętrzne obwody modułu działają w normie.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik inżynieryjny i instalacyjny\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLogika głosowania i konfiguracja\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUżyj oprogramowania do konfiguracji szafy 3500, aby zaprogramować logikę sterowania alarmem. System obsługuje złożone kombinacje indywidualnych poziomów procesów sond (PPL) i statusów alarmowych. Dla krytycznych maszyn zalecamy stosowanie logiki głosowania „2 z 2” lub „2 z 3”, aby zminimalizować ryzyko fałszywych wyłączeń spowodowanych awarią pojedynczego czujnika, jednocześnie utrzymując wysoką integralność ochrony.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOchrona styków przekaźnika\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChociaż \u003cstrong\u003e3500\/32-01-00\u003c\/strong\u003e jest standardowo wyposażony w tłumiki łuku 250 Vrms, zawsze upewnij się, że zewnętrzne obciążenie nie przekracza 5 A przy 240 VAC. Jeśli przełączasz obciążenia silnie indukcyjne, takie jak duże elektromagnesy lub ciężkie rozruszniki silników, rozważ użycie przekaźników pośrednich lub dodatkowych tłumików zewnętrznych, aby wydłużyć żywotność styków wewnętrznych komponentów uszczelnionych epoksydowo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZarządzanie środowiskowe i termiczne\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChociaż moduł jest przystosowany do pracy do 65 °C, utrzymanie stabilnej temperatury w szafie sterowniczej znacznie poprawi długoterminową niezawodność mechanicznych elementów przekaźnika. Zapewnij odpowiedni przepływ powietrza w szafie 3500 i unikaj umieszczania modułów generujących wysoką temperaturę bezpośrednio obok modułu przekaźnikowego, jeśli temperatura otoczenia w szafie zbliża się do górnej granicy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322972011,"sku":"3500\/32-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350032-01-00-bentlynevada-sipfc4xnpzw_b3862a43-3b98-4ce5-97d4-e1fd85e14c2b.jpg?v=1765521215"},{"product_id":"3500-15-07-07-00-bently-nevada-power-supply-module","title":"3500\/15-07-07-00 | Bently Nevada | Moduł zasilania","description":"\u003ch3\u003eZnaczenie operacyjne i integracja z szafą\u003c\/h3\u003e\n\u003cp\u003eModuł Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-07-07-00 (3500\/15-07-07-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estanowi podstawę wysokiej dostępności systemu ochrony maszyn 3500, dostarczając regulowane zasilanie do wszystkich zainstalowanych kart monitorujących i komunikacyjnych. Ta specyficzna redundantna konfiguracja niskonapięciowego prądu stałego została zaprojektowana do krytycznych zastosowań w przetwórstwie gazu ziemnego, ciężkich zakładach petrochemicznych oraz na platformach wiertniczych na morzu. Praca w tych trudnych warunkach wymaga infrastruktury zasilania bez awarii. Poprzez ustanowienie wymiennego na gorąco, podwójnie redundantnego zasilania w pojedynczym slocie obudowy, system całkowicie izoluje komponenty szyny zasilającej od zewnętrznych przepięć. Konstrukcja z podwójnym zasilaniem gwarantuje nieprzerwane monitorowanie, zapobiegając fałszywym wyłączeniom lub utracie diagnostyki maszyn w całym zakładzie podczas nieoczekiwanych przerw w dostawie zasilania.\u003c\/p\u003e\n\u003ch3\u003eRozkodowanie nazewnictwa sufiksów\u003c\/h3\u003e\n\u003cp\u003eKod opcji inżynieryjnych modułu\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-07-07-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eokreśla jego specyficzną konfigurację dwuslotową oraz zakres certyfikacji:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e: Podstawowa specyfikacja produktu dla modułu zasilania wysokiej wydajności serii 3500.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e07 (pierwszy sufiks)\u003c\/strong\u003e: Określa zasilacz niskonapięciowy DC w górnym slocie (przyjmuje zakres wejściowy zazwyczaj od 20 VDC do 30 VDC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e07 (drugi sufiks)\u003c\/strong\u003e: Określa dopasowany zasilacz niskonapięciowy DC w dolnym slocie, tworząc w pełni aktywną konfigurację redundantną.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Oznacza standardowe opcje bez specjalnych zatwierdzeń agencji.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePodstawowe specyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr metryczny\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWartość certyfikowana\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/15-07-07-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarka\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePochodzenie\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStany Zjednoczone (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNapięcie wejściowe (górny \/ dolny)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePodwójne niskonapięciowe DC (zazwyczaj 20 VDC do 30 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNiezawodność operacyjna\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAktywna redundancja zasilania z dwóch źródeł z możliwością wymiany na gorąco\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWymiary (D x S x W)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25,15 cm x 5,08 cm x 12,07 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperatura pracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C do 65°C (-22°F do 149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOchrona systemu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOchrona przed przepięciem, zwarciem i odwrotną polaryzacją\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWaga netto\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,80 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWaga wysyłkowa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,0 kg (wraz z wytrzymałym opakowaniem antystatycznym)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDiagnostyka funkcjonalna i najczęściej zadawane pytania dotyczące wdrożenia\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy moduł 3500\/15-07-07-00 może pracować ciągle na jednej karcie zasilającej?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Tak. Pojedyncza karta niskonapięciowego DC jest w stanie zasilić w pełni załadowaną szafę monitorującą 3500. Redundantna konfiguracja z dwoma slotami (-07-07) działa w trybie aktywnego dzielenia obciążenia. Jeśli jedna karta straci zasilanie, druga natychmiast przejmuje całe obciążenie prądowe bez przerywania pracy szyny zasilającej.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy możliwe jest mieszanie zasilaczy wysokiego napięcia AC i niskiego napięcia DC w tej samej obudowie 3500\/15?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Chociaż obudowa 3500\/15 może obsługiwać konfiguracje mieszane napięć w innych wariantach sufiksów, ten konkretny model (07-07) jest przeznaczony wyłącznie do podwójnego zasilania niskonapięciowego DC. Uruchomienie różnych napięć w tym urządzeniu wymaga wymiany jednej z kart na odpowiadający moduł wysokiego napięcia AC lub DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jak system sygnalizuje awarię jednego z redundantnych źródeł zasilania?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Panel przedni obudowy zasilacza posiada niezależne diody LED OK dla górnego i dolnego modułu zasilania. Dodatkowo, szyna zasilająca zawiera dedykowane styki beznapięciowe do podłączenia zewnętrznych pętli sygnalizacyjnych DCS lub PLC, które informują operatorów o awarii pojedynczego źródła zasilania.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstrukcja konserwacji i instalacji na miejscu\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOddzielenie redundantnego okablowania DC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAby zmaksymalizować korzyści z podwójnej redundancji zasilania, zawsze podłączaj górny i dolny slot do całkowicie niezależnych zewnętrznych systemów dystrybucji zasilania DC. Konsolidacja obu zasilaczy do jednego źródła zasilania niweczy cel redundancji sprzętowej i grozi całkowitym wyłączeniem szafy w przypadku awarii pojedynczego źródła.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZapewnienie bezpieczeństwa podczas wymiany na gorąco:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodczas wymiany uszkodzonej karty zasilającej na gorąco, gdy szafa ochrony maszyn jest aktywna, upewnij się, że dioda LED OK na panelu przednim pozostałego modułu zasilania świeci się na zielono. Ostrożnie poluzuj śruby motylkowe i wysuń kartę poziomo, aby zapobiec uszkodzeniom łuku styków złotych pinów na szynie zasilającej.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWłaściwe odstępy wentylacyjne:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUpewnij się, że otwory wentylacyjne w obudowie modułu zasilania są wolne od zatorów. Zamontuj szafę z minimalnym odstępem 50 mm (2 cale) powyżej i poniżej obudowy, aby utrzymać pasywną konwekcję cieplną, szczególnie podczas pracy blisko górnej granicy temperatury otoczenia 65°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323660139,"sku":"3500\/15-07-07-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-07-07-00-220ho13fdnh_6688e7ac-f49a-49c6-9749-8121668820e4.jpg?v=1765521241"}],"url":"https:\/\/www.plcprotech.com\/pl\/collections\/power-electrical-components.oembed?page=3","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}