{"title":"Transducers","description":"\u003cp\u003eTransducers are precision devices that convert mechanical or physical variables into standard electrical signals for monitoring and control. The architecture involves advanced sensing elements, such as piezoelectric or strain gauges, integrated with signal-conditioning electronics in robust housings. Technical characteristics include high linearity, wide frequency response, and standardized voltage or current outputs. Functionally, transducers measure parameters like pressure, vibration, or displacement from \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/probes\"\u003eprobes\u003c\/a\u003e and transmit the data to \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/i-o-modules\"\u003eI\/O modules\u003c\/a\u003e. This conversion is fundamental for providing the controller with accurate real-time feedback on machine health and process performance, allowing for precise automated adjustments and machinery protection.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-3500-40m-140734-01-proximitor-monitor","title":"Monitor Proximitor Bently Nevada 3500\/40M 140734-01","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eBently Nevada 3500\/40M (Numer części: 140734-01) to wysokowydajny, czterokanałowy moduł monitorujący ochronę maszyn, zaprojektowany dla systemu ochrony maszyn serii 3500. Urządzenie przyjmuje ciągłe sygnały analogowe z różnych przetworników zbliżeniowych Bently Nevada, przetwarzając je w celu śledzenia krytycznych parametrów wału, w tym drgań promieniowych, ekscentryczności, pozycji osiowej, REBAM i rozszerzenia różnicowego.\u003c\/p\u003e\n\u003cp\u003ePrzetwarzane parametry są ciągle porównywane z programowalnymi przez użytkownika progami alarmowymi, aby wykonywać automatyczne awaryjne wyłączenia maszyn. Konfiguracja 140734-01 reprezentuje główny układ wewnętrznego zakończenia sprzętowego, który łączy płytę tylnego panelu systemu bezpośrednio z czujnikami terenowymi. Ten moduł dostarcza dane ochrony maszyn operatorom zakładu, jednocześnie wysyłając zmienne diagnostyczne do sieci zarządzania zasobami.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumer części głównej płyty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140734-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuł monitorujący Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKompatybilność systemu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem ochrony maszyn serii 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePojemność kanałów\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 niezależne kanały na moduł\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCel wejścia sygnału\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePrzetworniki zbliżeniowe prądów wirowych\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUkład zakończenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterfejs wewnętrznego zakończenia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramowalne funkcje\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWibracje promieniowe, pozycja osiowa, ekscentryczność, REBAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eParametry punktów alarmowych\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 poziomy alarmowe, 2 poziomy niebezpieczeństwa na aktywny kanał\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrędkość przetwarzania sygnału\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCiągłe próbkowanie analogowe w czasie rzeczywistym\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWskaźniki stanu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDioda LED OK, TX\/RX i Bypass na panelu przednim\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary (SxWxG)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,6 cm x 25,8 cm x 24,0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga netto produktu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,80 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKraj pochodzenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStany Zjednoczone (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInformacje o zamówieniach\u003c\/h3\u003e\n\u003cp\u003eKonserwacja przemysłowych maszyn wirnikowych wymaga śledzenia dokładnych numerów części modułów, aby zapewnić kompatybilność z istniejącymi płytami tylnego panelu i konfiguracjami monitoringu.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOznaczenie typu modułu:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/40M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIdentyfikator głównego zespołu drukowanego (PWA):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e140734-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePodtyp komponentu I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModuł I\/O Proximitor z wewnętrznym zakończeniem\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik konfiguracji sprzętu i inżynierii\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eZasady konfiguracji par kanałów\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3500\/40M przetwarza sygnały z czujników zbliżeniowych za pomocą sparowanych ścieżek kanałów (Kanały 1 i 2 oraz Kanały 3 i 4). Przy przypisywaniu trybów funkcjonalnych za pomocą oprogramowania 3500 Rack Configuration Software, zaprogramowane wybory muszą być zgodne z wytycznymi dotyczącymi konfiguracji par. Na przykład, można jednocześnie wykonywać do dwóch różnych funkcji monitorowania na jednej parze, pod warunkiem, że podstawowe częstotliwości próbkowania przetworników są zgodne. Nieodpowiednie typy czujników na wspólnej parze kanałów spowodują błędy walidacji oprogramowania podczas przesyłania konfiguracji.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWewnętrzne zakończenia okablowania polowego\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePonieważ 140734-01 posiada wewnętrzne zakończenia, kable przedłużające czujniki polowe podłącza się bezpośrednio do zacisków śrubowych z tyłu modułu.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrzygotowanie:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsuń izolację poszczególnych przewodów na dokładnie 7 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOkablowanie:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUżywaj skręconego, ekranowanego kabla trzyżyłowego dla każdego połączenia sondy (\u003cstrong\u003eZasilanie, Sygnał, Komunikacja\u003c\/strong\u003e), aby odizolować system od zakłóceń elektromagnetycznych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUziemienie:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePodłącz zewnętrzne ekrany kabli do dedykowanej szyny uziemiającej instrumentacji wewnątrz obudowy szafy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProcedura wymiany na gorąco\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModuł 3500\/40M obsługuje wymianę na gorąco, gdy główna szafa jest zasilana. Jednak usunięcie aktywnego modułu monitora natychmiast powoduje zadziałanie przekaźnika \"OK\" i wprowadza zależne kanały w stan nieprawidłowy.\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eZmień fizyczny przełącznik blokady klucza szafy z\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"RUN\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ena\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etryb.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWłącz flagi\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eomijania kanału\u003c\/strong\u003e w oprogramowaniu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWyjmij uszkodzoną płytę 140734-01, aby uniknąć wywołania fałszywego awaryjnego wyłączenia maszyny.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ dotyczące konserwacji i rozwiązywania problemów\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jaka jest funkcjonalna różnica między monitorami 3500\/40M a starszymi 3500\/40?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Oznaczenie \"M\" wskazuje na rozszerzone możliwości przetwarzania. Model 3500\/40M posiada szybsze wewnętrzne pętle przetwarzania sygnału, rozszerzone rejestry pamięci do rejestracji danych przejściowych oraz bardziej efektywne przesyłanie ciągłych wartości statycznych do nowoczesnych sieci sterowania.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Z którymi przetwornikami polowymi można zintegrować moduł 140734-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Ten moduł jest zoptymalizowany dla systemów przetworników Bently Nevada Proximitor o średnicach 8 mm, 11 mm i 25 mm. Obsługuje standardowe długości pętli 5 i 9 metrów, przekształcając surowe wartości napięcia szczeliny na skalibrowane odczyty drgań lub położenia.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jak diody LED na panelu przednim pomagają w diagnostyce i rozwiązywaniu problemów?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStały zielony \"OK\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNormalna praca.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMigający czerwony \"OK\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWewnętrzna usterka sprzętowa lub niezgodność konfiguracji.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMigający bursztynowy \"TX\/RX\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAktywna komunikacja przez wewnętrzne linie magistrali danych szafy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515161451,"sku":"3500\/40M 140734-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-40m-140734-01-proximitor-monitor-fzuhngamh0b_6277bb18-daed-4044-bae8-f490e4d427b0.jpg?v=1765440072"},{"product_id":"bently-nevada-330180-90-cn-3300-xl-proximitor-sensor","title":"Czujnik Bently Nevada 330180-90-CN 3300 XL Proximitor","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003eModel\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN \u003c\/strong\u003eto wysokiej klasy nadajnik przemieszczenia prądów wirowych zaprojektowany przez Bently Nevada dla platformy monitorowania drgań\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Funkcjonując jako główny moduł kondycjonujący elektronikę w obwodzie przetwornika bezkontaktowego, moduł ten przekształca wysokoczęstotliwościowe fluktuacje radiowe na liniowe napięcie proporcjonalne do ruchu celu. Infrastruktury ciężkich maszyn obrotowych — w tym elektrownie cieplne, rafinerie petrochemiczne oraz ciągłe młyny górnicze — polegają na\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edo monitorowania dynamicznego stanu łożysk z filmem płynnym. Zapewniając bezpośrednią kompatybilność wsteczną z przestarzałymi instrumentami, czujnik ten dokładnie monitoruje drgania wału i pozycje osiowe. Pozwala to zespołom inżynierskim na wczesne wykrywanie niewłaściwego ustawienia konstrukcji, zapobieganie poważnym awariom maszyn oraz eliminowanie nieplanowanych przestojów produkcyjnych.\u003c\/p\u003e\n\u003ch3\u003eRozbicie sufiksu\u003c\/h3\u003e\n\u003cp\u003eMontaż mechaniczny, całkowite strojenie pętli oraz krajowe certyfikaty bezpieczeństwa dla\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eczujnika zbliżeniowego są systematycznie kategoryzowane przez jego specyficzne opcje sufiksów alfanumerycznych.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180 Kod bazowy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentyfikuje podstawową platformę sprzętową dla wysokostabilnego czujnika Proximitor 3300 XL.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-90 Parametr długości systemu:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUstala całkowitą skalibrowaną długość pętli systemu na 9,0 metrów (29,5 stopy), zoptymalizowaną wyłącznie pod kątem montażu na płaskiej powierzchni panelu. Wewnętrzny obwód oscylatora dopasowuje specyficzny profil impedancji połączonej sondy i kabla przedłużającego o długości 9,0 metrów bez konieczności kalibracji w terenie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-CN Specjalny token zatwierdzenia:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOznacza zgodność z regionalnymi certyfikatami obszarów zagrożonych, spełniając specjalistyczne normy bezpieczeństwa przemysłowego dla zastosowań w lokalnych, wysokiego ryzyka zautomatyzowanych obszarach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje wydajności i ograniczenia strukturalne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMetryka telemetrii maszyn\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWartość inżynierii czujników przemysłowych\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIdentyfikacja modelu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-90-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProducent marki\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (jednostka biznesowa Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinia systemu sterowania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeria pomiarowa przetworników 3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfejs przetwornika\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eObsługuje sondy serii 3300 o średnicy 5 mm, 3300 o średnicy 8 mm oraz 3300 XL o średnicy 8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMateriał bloku obudowy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eObudowa z odlewanego aluminium klasy premium A308\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCałkowite strojenie systemu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKalibracja pętli współdzielonej o długości 9,0 metrów (29,5 stopy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUkład montażu na obudowie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKonfiguracja montażu na płaskiej powierzchni panelu\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominalna skala wyjściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7,87 V\/mm (200 mV\/mil) liniowy wektor skalowania\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominalne napięcie robocze\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWejście zasilania o ujemnym potencjale -24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga netto urządzenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,246 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOkno termiczne pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 do +100°C Rozszerzony zakres temperatur otoczenia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 do +105°C Maksymalne granice strukturalne\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMiejsce produkcji\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStany Zjednoczone (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ dotyczące kompatybilności przetworników i diagnostyki\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eJakie przestarzałe komponenty sprzętowe zastępuje 330180-90-CN w aktywnych szafach sterowniczych?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModel 330180-90-CN stanowi zaawansowaną bezpośrednią modernizację technologiczną przestarzałych komponentów, całkowicie zastępując stare \u003cstrong\u003e330100-90-02\u003c\/strong\u003e oraz modele 330100-90-05. Umożliwia bezproblemową modernizację typu drop-in bez konieczności wymiany istniejących kompatybilnych sond polowych, chroniąc inwestycje infrastrukturalne.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten konkretny model Proximitor może być dostarczony z zatwierdzoną dokumentacją śledzenia produkcji?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak. Ponieważ ten przemysłowy przetwornik jest produkowany w Stanach Zjednoczonych, oficjalny Certyfikat Pochodzenia (COO) może zostać dołączony do dokumentacji technicznej na życzenie projektu, spełniając wymagania systemu zarządzania jakością i międzynarodowe parametry importowe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie warianty sond polowych można podłączyć do zacisków wejściowych tego czujnika?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCzujnik zawiera adaptacyjny stopień wejściowy, który obsługuje różne bezkontaktowe czujniki Bently Nevada. Działa niezawodnie z tradycyjnymi sondami serii 3300 o średnicy 5 mm, standardowymi sondami serii 3300 o średnicy 8 mm lub zaawansowanymi sondami 3300 XL 8 mm oraz dopasowanymi kablami przedłużającymi ułożonymi w pętlę o długości 9,0 metra.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik inżynieryjny i instalacyjny\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIzolacja złącza koncentrycznego i zabezpieczenia przed wilgocią:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePodczas podłączania sondy zbliżeniowej do kabla przedłużającego, całkowicie ekranij złącze koncentryczne za pomocą izolacji z silikonu o wysokiej dielektryczności. Jeśli metalowe osłony koncentryczne dotkną ramy maszyny, utworzą wtórne ścieżki uziemienia powodujące zniekształcenia sygnału. Owiń gotowe złącze taśmą samowulkanizującą, aby zapobiec przedostawaniu się wilgoci lub oleju, które mogłyby destabilizować dane czujnika RF.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWybór i weryfikacja celu napięcia szczeliny DC:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUstaw fizyczną pozycję końcówki sondy, śledząc napięcie szczeliny DC na zaciskach Proximitor za pomocą skalibrowanego multimetru. Reguluj głębokość sondy wewnątrz obudowy maszyny, aż napięcie wyniesie dokładnie -10,0 VDC, co ustawia cel dokładnie w centrum liniowego zakresu czujnika. Ostrożnie dokręć nakrętkę blokującą sondę, aby zapobiec przesunięciom podczas pracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eŚcieżki uziemienia ekranu i izolacja szumów:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProwadź linie zasilające i pętle sygnałowe z dala od przewodów silnika wysokiego napięcia, używając skręcanych, ekranowanych kabli pomiarowych. Podłącz ekran kabla tylko do głównego uziemienia na listwie zaciskowej panelu monitorowania maszyn, odcinając ekran czysto na końcu czujnika. Ta praktyka zapobiega prądom pętli masy, które wprowadzają zakłócenia do kart przetwarzania drgań.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515521899,"sku":"330180-90-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-cn-proximitor-sensor-w254xy3equw_73962b30-817f-4e70-9998-c31a1f0328f9.jpg?v=1765440079"},{"product_id":"bently-nevada-330180-92-05-3300-xl-proximitor-sensor","title":"Czujnik Bently Nevada 330180-92-05 3300 XL Proximitor","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e330180-92-05\u003c\/strong\u003e\u003c\/span\u003e to wysokoprecyzyjne urządzenie kondycjonujące przemieszczenie prądu wirowego opracowane przez Bently Nevada dla serii monitorowania stanu maszyn \u003cstrong\u003e3300 XL\u003c\/strong\u003e. Działając jako podstawowy moduł przetwarzania sygnału w obwodzie bezkontaktowej sondy zbliżeniowej, sprzęt ten przekształca surowe zmiany pola radiowego (RF) w liniowe wartości napięcia proporcjonalne bezpośrednio do położenia wału. Krytyczne dla misji zasoby przemysłowe — w tym duże generatory turbin parowych w elektrowniach, wysokociśnieniowe sprężarki odśrodkowe w rafineriach ropy naftowej oraz ciężkie młyny szlifierskie w zakładach przetwórstwa górniczego — polegają na \u003cspan\u003e\u003cstrong\u003e330180-92-05 (330180-92-05)\u003c\/strong\u003e\u003c\/span\u003e do monitorowania dynamicznego luzu łożysk hydrodynamicznych. Dostarczając stabilne, submikronowe odczyty drgań i siły osiowej bezpośrednio do systemu 3500 rack, czujnik ten wykrywa wczesne objawy drgań olejowych lub niewspółosiowości wału. Zapobiega to nieoczekiwanym, katastrofalnym zatrzymaniom maszyn, chroni kosztowne wały obrotowe i redukuje nieplanowane przestoje w fabryce.\u003c\/p\u003e\n\u003ch3\u003eRozbicie sufiksu\u003c\/h3\u003e\n\u003cp\u003eDokładna konfiguracja sprzętowa, kalibracja całkowitej pętli systemowej oraz profil zatwierdzenia do stref zagrożonych wybuchem czujnika zbliżeniowego \u003cspan\u003e\u003cstrong\u003e330180-92-05\u003c\/strong\u003e\u003c\/span\u003e mogą być systematycznie odczytane dzięki strukturze alfanumerycznego sufiksu.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePodstawa produktu 330180:\u003c\/strong\u003e Określa podstawową klasyfikację sprzętu dla wysokowydajnej jednostki czujnika zbliżeniowego 3300 XL.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpcja długości systemu -92:\u003c\/strong\u003e Określa całkowitą skalibrowaną długość pętli systemowej wynoszącą 9,0 metra (29,5 stopy). Parametr ten zapewnia, że wewnętrzny oscylator dopasowuje impedancję zestawu sondy i kabla przedłużającego o długości 9,0 metra bez konieczności lokalnej kalibracji w terenie. Opcja ta precyzuje obudowę montowaną na panelu bez specjalistycznego sprzętu do montażu na szynie DIN.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpcja zatwierdzenia wieloagencyjnego -05:\u003c\/strong\u003e Potwierdza, że moduł spełnia surowe międzynarodowe normy przeciwwybuchowe dla stref zagrożonych, posiadając pełne, jednoczesne certyfikaty bezpieczeństwa CSA, ATEX i IECEx do instalacji w strefach 0, 1 i 2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandardy wydajności technicznej i wymiary\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr ochrony maszyn\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWartość inżynieryjna czujnika przemysłowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIdentyfikacja modelu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-92-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProducent marki\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (jednostka biznesowa Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinia systemu sterowania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatforma przetwornika zbliżeniowego 3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfejs przetwornika\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eObsługuje sondy serii 3300 o średnicy 5 mm, 3300 o średnicy 8 mm oraz 3300 XL o średnicy 8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMateriał konstrukcyjny obudowy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWysokiej jakości odlewana aluminiowa obudowa A308\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKalibracja skali systemu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9,0 metra (łączna długość sondy i kabla)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCzynnik skali sygnału\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7,87 V\/mm (200 mV\/mil) nominalny liniowy sygnał wyjściowy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrąd roboczy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA do 12 mA nominalnego poboru prądu\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNapięcie zasilania nominalne\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC ujemne zasilanie przez szafę monitorującą\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga netto sprzętu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,246 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZakres temperatur pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 do +100 °C rozszerzony zakres otoczenia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZakres temperatur przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 do +105 °C zakres przechowywania\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMiejsce produkcji\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStany Zjednoczone (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ dotyczące konserwacji i eksploatacji przetwornika\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten czujnik Proximitor o długości 9,0 metra może działać z standardowym kablem przedłużającym o długości 5,0 metra?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie. Wewnętrzna matryca oscylacji 330180-92-05 jest specjalnie dostrojona do dopasowania pojemnościowych i indukcyjnych właściwości systemu o długości 9,0 metra. Łączenie tego modułu z sondą i kablem o długości 5,0 metra zmienia częstotliwość rezonansową, co powoduje zmianę czynnika skali z nominalnych 7,87 V\/mm (200 mV\/mil) i skutkuje nieprawidłowymi danymi o drganiach.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJakie konkretne korzyści terenowe zapewnia obudowa z odlewanego aluminium A308?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWysokiej jakości obudowa z odlewanego aluminium A308 działa jako trwała osłona blokująca wysokoczęstotliwościowe zakłócenia elektromagnetyczne (EMI) i szumy radiowe, które mogłyby wpływać na wewnętrzne obwody. Zapewnia również doskonałą ochronę fizyczną przed uderzeniami mechanicznymi, korozją atmosferyczną oraz wilgocią w trudnych warunkach na pokładach sprężarek.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak technik elektryk rozpoznaje zwarcie sondy od przerwy w obwodzie podczas pracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePoprzez pomiar napięcia DC na zaciskach czujnika technicy terenowi mogą szybko sprawdzić integralność systemu. Odczyt 0 VDC lub bardzo niskiej wartości dodatniej wskazuje na zwarcie, zwykle spowodowane zgniecionym przewodem lub uziemionym zaciskiem. Natomiast odczyt odpowiadający pełnemu napięciu zasilania (-24 VDC) wskazuje na przerwę w obwodzie, co oznacza zerwany przewód lub uszkodzoną końcówkę sondy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePoradnik inżynieryjny i instalacyjny\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIzolacja złącza koncentrycznego i ochrona przed wilgocią:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePodczas łączenia przewodu sondy z kablem przedłużającym w uchwycie maszyny, połączenie koncentryczne musi być całkowicie izolowane od ramy maszyny za pomocą silikonowych tulei o wysokiej dielektryczności. Wilgoć lub brud w tym połączeniu może pogorszyć sygnał RF, powodując natychmiastowe dryfowanie pomiarów. Zakończone połączenie owiń taśmą wulkanizującą samowulkanizującą się, aby zapobiec przedostawaniu się wilgoci na otwartych pokładach sprężarek.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWyrównanie napięcia szczeliny i punkty kalibracji:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePodczas instalacji ustaw fizyczną szczelinę sondy za pomocą multimetru cyfrowego podłączonego do zacisków „OUT” i „COM” czujnika. Obracaj korpus sondy, aż napięcie DC wyniesie dokładnie -10,0 VDC, co odpowiada precyzyjnemu środkowi liniowego zakresu kalibracji czujnika. Dokładnie dokręć nakrętkę blokującą sondy zgodnie z zalecanym momentem instalacyjnym, aby zapobiec mechanicznemu przesunięciu podczas pracy turbin o wysokich drganiach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUkład okablowania płytki zaciskowej i protokoły izolacji szumów:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePoprowadź pętle zasilania -24 VDC i sygnału wyjściowego przez wysokiej jakości skręcane, ekranowane kable pomiarowe. Uziemiaj ekrany kabli tylko w jednym punkcie, zwykle na zaciskach szafy monitorującej 3500, a ekran w polu przy czujniku przetnij czysto. Ta technika uziemienia zapobiega powstawaniu pętli masy, które mogłyby wprowadzać zakłócenia elektryczne do kanałów monitorowania drgań.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515620203,"sku":"330180-92-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-92-05-proximitor-sensor-2qdeihaxoud_6675da58-f3f4-4717-a992-7d62ce7a6bbd.jpg?v=1765440080"},{"product_id":"bently-nevada-176449-02-3500-42m-proximitor-seismic-monitor","title":"Bently Nevada 176449-02 3500\/42M Proximitor Monitor Sejsmiczny","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e176449-02 (3500\/42M)\u003c\/strong\u003e\u003c\/span\u003e to wysokowydajny czterokanałowy monitor drgań zaprojektowany dla systemu ochrony maszyn Bently Nevada 3500. Przeznaczony do krytycznych urządzeń w energetyce, przemyśle naftowym i gazowym oraz ciężkim przemyśle wytwórczym, moduł ten akceptuje sygnały z przetworników zbliżeniowych, prędkości i przyspieszenia. Jego główną rolą jest ciągła ochrona maszyn poprzez porównywanie na żywo danych o drganiach z ustawionymi przez użytkownika progami alarmowymi. Dzięki wykrywaniu wczesnych oznak niewyważenia wału, zużycia łożysk lub niewyważenia, \u003cspan\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e\u003c\/span\u003e umożliwia zespołom utrzymania ruchu przeprowadzanie działań predykcyjnych, skutecznie eliminując katastrofalne awarie maszyn i znacznie redukując nieplanowane przestoje zakładu.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003eMonitor 3500\/42M wykorzystuje architekturę z dwoma parami kanałów, co pozwala na elastyczne strategie monitorowania w pojedynczym slocie szafy.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgramowanie kanałów:\u003c\/strong\u003e Kanały są konfigurowane parami (1\/2 i 3\/4), obsługując jednoczesne funkcje. Na przykład jedna para może monitorować drgania promieniowe, podczas gdy druga para śledzi pozycję osi lub przyspieszenie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGenerowanie wartości statycznych:\u003c\/strong\u003e Moduł przetwarza surowe sygnały z przetworników na parametry operacyjne, takie jak Direct, Gap, 1X i 2X Vector, Smax oraz Eccentricity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogika filtracji:\u003c\/strong\u003e Wyposażony w programowalne filtry jednobiegunowe (4 Hz do 4000 Hz) oraz filtry notch o stałej Q dla monitorowania \"Not 1X\" i wektorów, zapewnia wysoką jakość sygnału nawet w hałaśliwym środowisku.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuforowane wyjścia:\u003c\/strong\u003e Koaksjalne złącza na przednim panelu zapewniają zabezpieczone przed zwarciem sygnały buforowane dla każdego kanału, umożliwiając bezpośrednie podłączenie do zewnętrznych analizatorów częstotliwości lub rejestratorów bez przerywania pętli ochrony.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e176449-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePochodzenie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePobór mocy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7,7 W typowo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedancja wejściowa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kOhm (standardowe I\/O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZasilanie przetwornika\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWyjście rejestratora\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 do 20 mA (indywidualne dla każdego kanału)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOpór obciążenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 do 600 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 do +65 stopni Celsjusza\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePasmo przenoszenia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Hz do 4000 Hz (programowalne przez użytkownika)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania dotyczące serwisu w terenie\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCo oznaczają diody LED na przednim panelu w kontekście stanu systemu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDioda OK wskazuje pomyślne przejście diagnostyki wewnętrznej 3500\/42M. Dioda TX\/RX miga, potwierdzając aktywną komunikację szeregową z modułem interfejsu szafy (RIM), natomiast dioda Bypass świeci, gdy monitor jest w trybie Bypass, co oznacza, że logika alarmowa jest wyłączona.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy monitor 3500\/42M może jednocześnie przetwarzać różne typy przetworników?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak, ponieważ kanały są programowane parami, można monitorować sygnały Proximitor na jednej parze, a sygnały sejsmiczne (prędkość\/przyspieszenie) na drugiej, pod warunkiem, że mieszczą się w obsługiwanym zakresie sygnału -24 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo się stanie, jeśli wyjście rejestratora zostanie zwarte?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePraca monitora i logika ochrony pozostają całkowicie nienaruszone przez zwarcia na wyjściach rejestratora 4-20 mA. Moduł posiada wewnętrzne zarządzanie zgodnością napięciową, które utrzymuje integralność sygnału w całym zakresie obciążenia.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWytyczne dotyczące instalacji i uruchomienia inżynieryjnego\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEkranowanie i uziemienie:\u003c\/strong\u003e Zawsze zakończ osłony kabli sygnałowych na zaciskach uziemienia modułu I\/O systemu 3500. Nigdy nie uziemiać osłony na obu końcach, ponieważ powoduje to pętle masy, które mogą zakłócać czułe sygnały drgań.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKorekta napięcia szczeliny:\u003c\/strong\u003e W zastosowaniach z sondami zbliżeniowymi zweryfikuj wartość statyczną \"Gap\" podczas instalacji. Upewnij się, że sonda jest ustawiona w liniowym zakresie przetwornika (zazwyczaj -10 VDC dla standardowych sond 8 mm), aby zapobiec przesterowaniu sygnału i utrzymać dokładne progi alarmowe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegralność okablowania:\u003c\/strong\u003e Upewnij się, że opór obciążenia wyjść rejestratora 4-20 mA nie przekracza 600 Ohm. Przekroczenie tego limitu spowoduje nasycenie sygnału, co skutkuje niedokładnym raportowaniem do DCS lub PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZarządzanie termiczne:\u003c\/strong\u003e Przy użyciu monitora w konfiguracjach o wysokiej gęstości w pobliżu limitu 65 stopni Celsjusza zapewnij odpowiednią wentylację szafy. Długotrwała praca w temperaturach szczytowych może pogorszyć dokładność rozdzielczości 4-20 mA (z 0,25% w temperaturze pokojowej do 0,7% przy granicznych temperaturach).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516734315,"sku":"3500\/42M 176449-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42m-176449-02-proximitor-seismic-monitor-k32jvb2xqxe_b0d50d43-00a9-4728-9846-a30a23c88b20.jpg?v=1765440095"},{"product_id":"bently-nevada-289837-01-3500-encore-proximitor-seismic-i-o-module","title":"Moduł Wejścia\/Wyjścia Proximitor\/Sejsmiczny Bently Nevada 289837-01 3500 ENCORE","description":"\u003ch3\u003ePrzegląd produktu\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e to wysokowydajny moduł wejścia\/wyjścia Proximitor\/Seismic zaprojektowany specjalnie dla systemu ochrony maszyn Bently Nevada 3500 ENCORE. Moduł ten pełni kluczową rolę jako interfejs tylnej płyty dla monitora drgań 3500\/42E, umożliwiając podłączenie do czterech kanałów czujników zbliżeniowych lub sejsmicznych. Szeroko stosowany w sektorach energetycznym, naftowym, gazowym i górniczym, \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e pozwala na monitorowanie istotnych parametrów maszyn, takich jak drgania promieniowe, pozycja osiowa i ekscentryczność. Zapewniając niezawodne kondycjonowanie sygnału i przesył do głównego procesora, moduł ten gwarantuje ciągłą ochronę maszyn oraz wysoką jakość pozyskiwanych danych. Jest niezbędnym elementem dla zakładów przechodzących z systemów 3300 na platformę ENCORE, umożliwiając nowoczesny monitoring drgań bez utraty integralności okablowania polowego.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003c\/h3\u003e\n\u003cp\u003eModuł wejścia\/wyjścia \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e został zaprojektowany tak, aby wspierać dwuarchekturalne możliwości serii 3500 ENCORE, zapewniając maksymalną elastyczność w monitorowaniu drgań i pozycji.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eObsługa czterech kanałów:\u003c\/strong\u003e W standardowej szafie systemu 3500 ENCORE moduł obsługuje cztery niezależne kanały, programowane parami (kanały 1 i 2; kanały 3 i 4) do realizacji określonych funkcji monitorowania.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWszechstronność czujników:\u003c\/strong\u003e Kompatybilny z szerokim zakresem czujników, w tym sondami zbliżeniowymi do pomiarów łożysk ślizgowych oraz czujnikami sejsmicznymi (akcelerometry lub czujniki prędkości) do pomiaru drgań obudowy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegracja systemowa:\u003c\/strong\u003e W konfiguracji systemu 3500 ENCORE moduł I\/O współpracuje z programowalnymi modułami przekaźnikowymi, które sterują obwodami awaryjnego wyłączenia maszyn na podstawie zdefiniowanych przez użytkownika progów Alarmu i Niebezpieczeństwa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogika kondycjonowania:\u003c\/strong\u003e Każdy kanał przetwarza surowe sygnały z czujników na „wartości statyczne”, dostarczając personelowi operacyjnemu diagnostykę stanu maszyn w czasie rzeczywistym zarówno w warunkach ustalonych, jak i przejściowych.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrybut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e289837-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeria\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 ENCORE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTyp modułu\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModuł wejścia\/wyjścia Proximitor\/Seismic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eObsługa kanałów\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kanały (tryb systemowy) \/ 2 kanały (aktualizacja szafy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 do +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 do +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWilgotność\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% bez kondensacji\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,68 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208,28 mm x 48,26 mm x 127 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNajczęściej zadawane pytania dotyczące zastosowań przemysłowych\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCzy moduł 289837-01 może być używany jako bezpośredni zamiennik modułów I\/O serii 3300?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNie. Chociaż system 3500 ENCORE jest zaprojektowany do modernizacji monitorów 3300, \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e jest przeznaczony wyłącznie do użytku w szafie systemu 3500 ENCORE. W konfiguracjach „aktualizacji szafy”, gdzie pozostaje obudowa 3300, system korzysta z istniejących modułów I\/O serii 3300.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten moduł I\/O obsługuje jednocześnie drgania promieniowe i pozycję osiową?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTak. Ponieważ kanały są programowane parami, można skonfigurować kanały 1 i 2 do monitorowania drgań promieniowych, a kanały 3 i 4 do położenia osiowego (lub innej obsługiwanej funkcji) w tym samym monitorze 3500\/42E.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJak moduł radzi sobie z błędami sygnału, takimi jak odłączony czujnik?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMonitor 3500\/42E, współpracujący z \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e, wykonuje ciągłe autodiagnostyki. W przypadku awarii sygnału czujnika lub uszkodzenia okablowania monitor zgłasza status „Nie OK”, zapobiegając fałszywym wyłączeniom i powiadamiając dział utrzymania ruchu za pomocą oprogramowania 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrzewodnik inżynierii terenowej i instalacji\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOkablowanie i ekranowanie:\u003c\/strong\u003e Podczas podłączania czujników Proximitor lub Seismic do zacisków \u003cspan\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003c\/span\u003e należy upewnić się, że ekrany kabli są uziemione wyłącznie przy module I\/O. Nie należy uziemiać ekranów po stronie czujnika, aby uniknąć pętli masy, które mogą wprowadzać zakłócenia i obniżać dokładność pomiaru drgań.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontaż i dokręcanie:\u003c\/strong\u003e Upewnij się, że moduł I\/O jest całkowicie osadzony z tyłu szafy ENCORE, a śruby mocujące są odpowiednio dokręcone, aby zabezpieczyć moduł przed tylną płytą. Jest to kluczowe dla zachowania integralności sygnału w środowiskach o wysokich drganiach, typowych dla stanowisk sprężarek lub hal turbin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOchrona środowiskowa:\u003c\/strong\u003e Chociaż moduł jest przystosowany do pracy przy wilgotności do 95% bez kondensacji, powinien być zawsze instalowany w obudowie o klasie NEMA 4 lub IP65, jeśli znajduje się w miejscach o wysokiej wilgotności lub obecności substancji korozyjnych. Zapewnij odpowiednią cyrkulację powietrza w szafie, aby utrzymać temperaturę pracy poniżej 65 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeryfikacja konfiguracji:\u003c\/strong\u003e Po wymianie modułu I\/O zawsze używaj oprogramowania 3500 Rack Configuration Software, aby potwierdzić, że parowanie kanałów i typy czujników odpowiadają zainstalowanym w terenie. Wykonaj test pętli, aby upewnić się, że progi Alarmu i Niebezpieczeństwa prawidłowo sterują powiązanymi modułami przekaźnikowymi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516898155,"sku":"3500\/42E 289837-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42e-289837-01-vibration-monitor-5lwybpzw3c4_d9f2ca71-9841-4ea7-b237-17c1fd8f0f71.jpg?v=1765440098"},{"product_id":"bently-nevada-140734-02-3500-42m-proximitor®-seismic-monitor","title":"Bently Nevada 140734-02 3500\/42M Proximitor®\/Monitor sejsmiczny","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/42M\u003c\/strong\u003e, oznaczony jako zespół części zamiennych \u003cstrong\u003e140734-02\u003c\/strong\u003e, jest czterokanałowym urządzeniem ochrony maszyn zaprojektowanym do przetwarzania sygnałów z przetworników zbliżeniowych i sejsmicznych. Moduł działa jako warstwa analityczna bezpieczeństwa w systemie ochrony maszyn 3500, przetwarzając analogowe sygnały falowe w celu obliczania zmiennych takich jak drgania promieniowe, pozycja osiowa, ekscentryczność lub prędkość oraz wykonując porównania z programowalnymi przez użytkownika progami alarmowymi. Programowany w parach kanałów za pomocą oprogramowania 3500 Rack Configuration Software, uruchamia automatyczne alarmy po przekroczeniu ustawionych limitów bezpieczeństwa. Sprzęt dostarcza indywidualne pętle prądowe +4 do +20 mA dla każdego kanału, aby przesyłać w czasie rzeczywistym wartości statyczne bezpośrednio do rozproszonych sieci sterowania i serwerów archiwizacji operacyjnej bez przerywania podstawowych operacji ochronnych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCztery niezależne kanały przetwarzania obsługujące wiele jednoczesnych typów funkcji drgań i położenia.\u003c\/li\u003e\n\u003cli\u003eElastyczne dopasowanie przetworników obsługujące standardowe sondy indukcyjne, akcelerometry i czujniki prędkości.\u003c\/li\u003e\n\u003cli\u003eArchitektury programowania kanałów parami umożliwiające różne operacje matematyczne na parach kanałów 1-2 i 3-4.\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne przypisanie progów alarmowych i niebezpieczeństwa wspierające szczegółowe limity bezpieczeństwa maszyn dla wszystkich obliczanych wartości statycznych.\u003c\/li\u003e\n\u003cli\u003eIndywidualne, przednie połączenia koncentryczne buforowanych przetworników zaprojektowane z ochroną przed zwarciem do diagnostyki strukturalnej.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eŚledzenie drgań promieniowych wału wirnika przemysłowej turbiny parowej oraz obserwacja pozycji osiowej.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie prędkości sejsmicznej obudowy dużych sprężarek gazowych odśrodkowych oraz ochrona mechaniczna przed awarią.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie drgań absolutnych wału turbiny gazowej do wytwarzania energii oraz ekscentryczności wirnika.\u003c\/li\u003e\n\u003cli\u003eAnaliza stanu łożysk tocznych pomp przemysłowych cieczy ciężkich za pomocą specjalistycznej logiki REBAM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKod opcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOpis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/42-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor sejsmiczny Proximitor®\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Typ modułu I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Seismic z zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Seismic z zakończeniami zewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O TMR Prox\/Seismic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi (4 kanały prox.\/akcelerometru) i zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi (2 kanały prox.\/akcelerometru + 2 kanały Velomitor®) i zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O z barierami wewnętrznymi (4 kanały Velomitor®) i zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O wału absolutnego z zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O wału absolutnego z zakończeniami zewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e09\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Velom z zakończeniami wewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eModuł I\/O Prox\/Velom z zakończeniami zewnętrznymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Opcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C (Klasa 1, Podział 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX\/CSA (Klasa 1, Strefa 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęści zamienne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e140734-02\u003c\/td\u003e\n\u003ctd\u003eMonitor Proximitor®\/Seismic 3500\/42M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140734-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWejścia sygnałowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAkceptuje 1 do 4 sygnałów z przetworników zbliżeniowych, prędkości lub przyspieszenia \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandardowa impedancja wejściowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ dla wejść Proximitor i przyspieszenia \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa magistrali TMR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEfektywna impedancja 50 kΩ przy 3 kanałach połączonych równolegle \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominalne zużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowe zużycie mocy 7,7 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWskaźniki stanu na panelu przednim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDioda LED OK, dioda LED TX\/RX, dioda LED obejścia \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorty wyjścia buforowanego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 koaksjalne złącza chronione przed zwarciem (1 na kanał) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wyjścia buforowanego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZasilanie przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjście prądowe rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 do +20 mA DC indywidualna pętla na kanał \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNapięcie zgodności rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZakres napięcia rejestratora 0 do +12 V DC na obciążeniu \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres rezystancji obciążenia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do 600 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRozdzielczość bitowa analogowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,3662 µA na bit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCzęstotliwość aktualizacji danych\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms lub mniej \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiltr rozszerzenia siły\/różnicowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiltr bezpośredni: -3 dB przy 1,2 Hz | Filtr szczelinowy: -3 dB przy 0,41 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność wartości statycznej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo w granicach ±0,33% pełnej skali, maksymalnie ±1% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność nastawy alarmu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW granicach 0,13% wartości docelowej \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres opóźnienia alarmu ostrzegawczego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 do 60 sekund w odstępach co 1 sekundę \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres opóźnienia alarmu niebezpieczeństwa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,1 sekundy lub 1 do 60 sekund w odstępach co 0,5 sekundy \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (I\/O standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 stopni Celsjusza do +65 stopni Celsjusza (-22 do +150 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (I\/O z barierą)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 stopni Celsjusza do +65 stopni Celsjusza (32 do 150 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 stopni Celsjusza do +85 stopni Celsjusza (-40 do +185 stopni Fahrenheita) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres wilgotności pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% wilgotności względnej bez kondensacji \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu monitorującego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg (2,0 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O (bez bariery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,20 kg (0,44 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaga modułu I\/O (bariera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu monitorującego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 91,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu I\/O (bariera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary zajmowane w szafie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pełnowysokościowy slot przedni i 1 pełnowysokościowy slot tylny \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/Interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Pin złącza\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKoaksjalne złącza na panelu przednim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuforowane wyjście chronione przed zwarciem do diagnostyki sygnału dynamicznego \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminale I\/O Prox\/Seismic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTylne bloki przewodów interfejsu do bezpośredniego wewnętrznego podłączenia czujników \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZewnętrzne złącza zakończeniowe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane wielopinowe złącza współpracujące z samodzielnymi blokami zaciskowymi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWyjścia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedykowane punkty połączeń pętli dla proporcjonalnej telemetrii +4 do +20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTłumienie szumów: Zapewnij dokładne utrzymanie parametrów ekranowania czujnika poprzez połączenie przewodów uziemiających przyrządów z określonymi punktami uziemienia obudowy na bloku I\/O, aby ograniczyć sprzężenie elektromagnetyczne.\u003c\/li\u003e\n\u003cli\u003eMapowanie wyrównania: Potwierdź, że główny zespół karty \u003cstrong\u003e140734-02\u003c\/strong\u003e ślizga się gładko po prowadnicach przedniego slotu szafy, mocno osadzając się w tylnych liniach magistrali danych.\u003c\/li\u003e\n\u003cli\u003eZasady zakończeń: Nigdy nie łącz zewnętrznych bloków zakończeniowych z modułami I\/O zaprojektowanymi i oznaczonymi do zastosowań wewnętrznego zakończenia.\u003c\/li\u003e\n\u003cli\u003ePrzydział miejsca: Zachowaj wolne linie przepływu powietrza na przednich i tylnych krawędziach ramy szafy, aby zapewnić niezakłócony przepływ powietrza przez obudowy modułów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDyrektywy niskonapięciowe CE: Wymagania bezpieczeństwa EN61010-01 dla przemysłowego sprzętu monitorującego.\u003c\/li\u003e\n\u003cli\u003eEkranowanie emisji EMC: Certyfikowane zgodnie z IEC\/EN 61000-6-4 oraz normą EN 55011 Klasa A.\u003c\/li\u003e\n\u003cli\u003eKryteria odporności EMC: Spełnia normy EN 61000-4-2 wyładowania elektrostatycznego (kryterium B) oraz EN 61000-4-3 odporności na promieniowanie (kryterium A).\u003c\/li\u003e\n\u003cli\u003eZatwierdzenia do stref zagrożonych wybuchem: CSA\/NRTL\/C Klasa I, Podział 2, Grupy A, B, C, D (klasa T4 przy Ta = -30°C do +65°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNajczęściej zadawane pytania techniczne i dotyczące zaopatrzenia\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy ten komponent może działać jako mechanizm absolutnego wyłączania maszyny przy nadmiernej prędkości?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO: Nie, to urządzenie jest specjalnie zaprojektowane do obsługi dynamicznych pomiarów proximitorów oraz przyspieszenia\/prędkości sejsmicznej, a nie do wyzwalaczy krawędzi koła prędkości o wysokiej częstotliwości potrzebnych do deterministycznych pętli ochrony przed nadmierną prędkością.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Jaka jest podstawowa różnica między oznaczeniem 3500\/42M a numerem części 140734-02?\u003c\/strong\u003e O: 3500\/42M to oficjalna klasyfikacja serii monitorów systemowych, natomiast kod 140734-02 to dokładny numer katalogowy zamówienia na wewnętrzną płytę główną do wymiany.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy nieoczekiwane zwarcie w pętli rejestratora prądu +4 do +20 mA zakłóci ochronę maszyn?\u003c\/strong\u003e O: Nie, obwód analogowej pętli prądowej jest wewnętrznie izolowany, co oznacza, że logika przetwarzania, funkcje monitorujące i alarmy bezpieczeństwa działają normalnie, nawet jeśli pętla rejestratora ulegnie zwarciu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Czy można zaprogramować kanał 1 do obliczania drgań promieniowych, podczas gdy kanał 2 ocenia pozycję osiową?\u003c\/strong\u003e O: Nie, kanały monitorujące są konfigurowane programowo w odrębnych parach funkcjonalnych, co oznacza, że kanały 1 i 2 muszą wykonywać tę samą podstawową funkcję, podczas gdy kanały 3 i 4 mogą obsługiwać inną.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Co się dzieje z wskaźnikami na przednim panelu, jeśli moduł napotka wewnętrzny błąd przetwarzania?\u003c\/strong\u003e O: Zielona dioda OK przestanie świecić ciągłym światłem, sygnalizując wystąpienie wyjątku sprzętowego i inicjując bezpieczny stan obejścia systemu, aby uniknąć fałszywych wyłączeń z powodu przekroczenia limitu.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517717355,"sku":"3500\/42M 140734-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42m-140734-02-proximitor-seismic-monitor-pwa-r0numhbecec_3ab792c9-f156-41de-b90f-53ed4538fa1b.jpg?v=1765440108"},{"product_id":"bently-nevada-330180-91-00-3300-xl-proximitor-sensor","title":"Czujnik Bently Nevada 330180-91-00 3300 XL Proximitor","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-91-00\u003c\/strong\u003e to \u003cstrong\u003eczujnik Proximitor 3300 XL\u003c\/strong\u003e skonfigurowany na długość systemu 9,0 m, wyposażony w płytkę montażową na szynę DIN 35 mm i dostarczany bez zatwierdzeń agencji. Czujnik ten działa poprzez kondycjonowanie i wzmacnianie sygnału z sondy prądów wirowych, przekształcając fizyczne przemieszczenie wału na proporcjonalny sygnał napięcia stałego do monitorowania wejść systemu.\u003c\/p\u003e\n\n\u003cp\u003eTa wersja różni się od konfiguracji montowanych na panelu (takich jak Opcja 90) poprzez zastosowanie podstawy montażowej na szynę DIN zajmującej węższy slot 35,1 mm, co pozwala na gęste rozmieszczenie w obudowach ochronnych. Podczas gdy inne konfiguracje zawierają zatwierdzenia dla stref zagrożonych (np. Opcja 05), ta konfiguracja (Opcja 00) jest przeznaczona do środowisk ogólnego przeznaczenia, gdzie zatwierdzenia agencji nie są wymagane.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOpcja 91 określa długość systemu elektrycznego 9,0 metra dopasowaną do sond 3300 XL 8 mm i kabli przedłużających.\u003c\/li\u003e\n  \u003cli\u003ePodstawa montażowa na szynę DIN zapewnia izolację elektryczną od powierzchni montażowej.\u003c\/li\u003e\n  \u003cli\u003eOpcja 00 określa konfigurację bez zatwierdzeń agencji dla stref zagrożonych.\u003c\/li\u003e\n  \u003cli\u003eZłocone mosiężne lub złocone miedziane łączniki berylowe zapewniają bezpieczne ścieżki sygnałowe.\u003c\/li\u003e\n  \u003cli\u003eListwy zaciskowe SpringLoc ułatwiają okablowanie w terenie bez mechanizmów zaciskowych na śruby.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePomiar drgań wału w turbinach parowych i gazowych, sprężarkach, silnikach i pompach.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie położenia osiowego wirujących wałów w maszynach przemysłowych.\u003c\/li\u003e\n  \u003cli\u003eBezkontaktowy monitoring przemieszczeń prądów wirowych w środowiskach przemysłowych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOpcja\u003c\/th\u003e\n      \u003cth\u003eKod tego SKU\u003c\/th\u003e\n      \u003cth\u003eOpis\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330180-91-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCzujnik Proximitor 3300 XL, długość systemu 9,0 m, montaż na szynie DIN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOpcja A - Całkowita długość i opcja montażu\u003c\/td\u003e\n      \u003ctd\u003e91\u003c\/td\u003e\n      \u003ctd\u003eDługość systemu 9,0 metrów (29,5 stopy), montaż na szynie DIN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOpcja B - Opcja zatwierdzenia agencji\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNie wymagane (Brak zatwierdzeń agencji)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-91-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeria produktu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp urządzenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCzujnik Proximitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDługość systemu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9,0 metrów (29,5 stopy)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja montażu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMontaż na szynie DIN 35 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZatwierdzenie agencji\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrak (nie wymagane)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKompatybilność wejścia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eObsługuje jeden bezkontaktowy czujnik zbliżeniowy 3300 XL 8 mm oraz kabel przedłużający\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymagania zasilania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17,5 Vdc do -26 Vdc przy maksymalnym poborze 12 mA; -23 Vdc do -26 Vdc z barierami\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpór wyjściowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 omów\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał obudowy czujnika\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAluminium A308\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał złącza\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMosiądz pozłacany lub miedź berylowana pozłacana\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51°C do +100°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81,3 mm x 35,1 mm x 89,4 mm (W x S x G)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0,246 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eEtykieta zacisku\u003c\/th\u003e\n      \u003cth\u003eFunkcja\u003c\/th\u003e\n      \u003cth\u003eSpecyfikacja okablowania\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003eWejście zasilania (-24 Vdc nominalne)\u003c\/td\u003e\n      \u003ctd\u003eObsługuje przewody o przekroju 0,2 do 1,5 mm2 (16 do 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eWspólny układ (ścieżka powrotna)\u003c\/td\u003e\n      \u003ctd\u003eObsługuje przewody o przekroju 0,2 do 1,5 mm2 (16 do 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWYJŚCIE\u003c\/td\u003e\n      \u003ctd\u003eProporcjonalny sygnał wyjściowy napięciowy\u003c\/td\u003e\n      \u003ctd\u003eObsługuje przewody o przekroju 0,2 do 1,5 mm2 (16 do 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMontaż:\u003c\/strong\u003e Zamontuj moduł na standardowej szynie DIN 35 mm. Zapewnij minimalny odstęp 3,05 mm nad urządzeniem, aby umożliwić łatwe zdjęcie z szyny DIN.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOkablowanie:\u003c\/strong\u003e Użyj ekranowanego kabla triadowego z 3 przewodnikami do połączenia wyjścia czujnika z systemem monitoringu. Maksymalna długość kabla nie powinna przekraczać 305 metrów (1000 stóp).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZaciski:\u003c\/strong\u003e Wykorzystaj listwy zaciskowe SpringLoc do szybkich, pewnych połączeń bez konieczności dokręcania śrub. Odsłonięte przewody wkłada się bezpośrednio do zacisków.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIzolacja elektryczna:\u003c\/strong\u003e Integralna podkładka montażowa zapewnia całkowitą izolację elektryczną od szyny DIN. Nie są wymagane dodatkowe zewnętrzne płyty izolujące.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKompatybilność elektromagnetyczna (EMC):\u003c\/strong\u003e Zgodne z normami dyrektywy Unii Europejskiej 2014\/30\/UE, w tym EN 61000-6-2 i EN 61000-6-4.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOgraniczenie substancji niebezpiecznych (RoHS):\u003c\/strong\u003e Zgodne z dyrektywą 2011\/65\/UE.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo funkcjonalne:\u003c\/strong\u003e Certyfikowane do SIL 2 (HFT = 0) i SIL 3 (HFT = 1) w granicach stosowania w kwalifikowanym systemie bezpieczeństwa.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZatwierdzenie do stref zagrożonych:\u003c\/strong\u003e Brak (Opcja 00 jest określona dla obszarów ogólnego przeznaczenia, niezagrożonych).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518897003,"sku":"330180-91-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-91-00-5-8-mm-proximitor-sensor-rcdw0doug3q_b421d6f1-53db-40f9-9769-1c1febddd9f7.jpg?v=1765440123"},{"product_id":"bently-nevada-330180-90-05-3300-xl-proximitor-sensor","title":"Czujnik Bently Nevada 330180-90-05 3300 XL Proximitor","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eOpcja 90 (długość systemu 9,0 metra, montaż na panelu) oraz opcja 05 (zatwierdzenia CSA, ATEX, IECEx) określają tę konfigurację czujnika Proximitor 3300 XL — \u003cstrong\u003e330180-90-05\u003c\/strong\u003eTen czujnik bezkontaktowy jest podstawowym modułem kondycjonującym dla systemów przetworników zbliżeniowych Bently Nevada 3300 XL, które służą do pomiaru drgań promieniowych wału, pozycji osiowej siły osiowej oraz prędkości obrotowej maszyn przemysłowych. Urządzenie zawiera specjalistyczne obwody oscylatora i demodulatora, które generują sygnał radiowy, sterują podłączoną sondą prądów wirowych i kondycjonują powracający sygnał do ciągłego napięcia analogowego proporcjonalnego do dynamicznej odległości szczeliny.\u003c\/p\u003e\n\n\u003cp\u003eTa wersja do montażu na panelu posiada standardową płytkę montażową z 4 otworami, która ma identyczny rozstaw jak starsze modele Proximitor, co ułatwia modernizacje starszych systemów. Aluminiowa podstawa montażowa zapewnia wbudowaną izolację elektryczną, eliminując konieczność stosowania oddzielnych płyt izolacyjnych. Skalibrowany dla systemów o długości 9,0 metra, model 330180-90-05 wymaga precyzyjnego dopasowania z sondą zbliżeniową 3300 XL 8 mm i kablem przedłużającym, których łączna długość fizyczna wynosi dokładnie 9,0 metra. Zgodność z opcją 05 dodaje certyfikowaną ochronę dla stref zagrożonych wybuchem, umożliwiając bezpieczne użytkowanie zgodnie z globalnymi standardami bezpieczeństwa wewnętrznego i przeciwwybuchowego.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eKonfiguracja opcji 90 określa kalibrację systemu o długości 9,0 metra dopasowaną do montażu na panelu z 4 otworami.\u003c\/li\u003e\n  \u003cli\u003eOpcja 05 zatwierdzenia agencji zapewnia certyfikowane bezpieczeństwo dla stref zagrożonych wybuchem zgodnie z aprobatami CSA, ATEX i IECEx.\u003c\/li\u003e\n  \u003cli\u003eStandardowy rozstaw montażu na panelu zapewnia kompatybilność wsteczną ze starszymi czujnikami Bently Nevada Proximitor.\u003c\/li\u003e\n  \u003cli\u003eZintegrowana izolacja elektryczna na podstawie montażowej eliminuje potrzebę stosowania oddzielnego sprzętu izolującego.\u003c\/li\u003e\n  \u003cli\u003eZłącza zaciskowe SpringLoc zapewniają bezpieczne połączenia okablowania w terenie bez potrzeby specjalnych narzędzi instalacyjnych.\u003c\/li\u003e\n  \u003cli\u003eZaawansowana odporność na zakłócenia RF\/EMI spełnia europejskie normy CE bez konieczności stosowania specjalnych ekranowanych przewodów lub metalowych obudów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePomiar drgań promieniowych wału i dynamicznego pozycjonowania na turbinach, sprężarkach i pompach o wysokich prędkościach.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie pozycji osiowej siły osiowej i ekscentryczności wału w zastosowaniach energetycznych i petrochemicznych.\u003c\/li\u003e\n  \u003cli\u003eCiągłe kondycjonowanie sygnału prędkości i tachometru na silnikach przemysłowych, generatorach i wentylatorach.\u003c\/li\u003e\n  \u003cli\u003ePętle monitorowania ochrony maszyn podłączone do szaf serii Bently Nevada 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOpcja \/ Segment\u003c\/th\u003e\n      \u003cth\u003eKod tego SKU\u003c\/th\u003e\n      \u003cth\u003eOpis \/ Znaczenie\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330180-90-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCzujnik Proximitor 3300 XL, długość systemu 9,0 m, montaż na panelu, zatwierdzony do stref zagrożonych wybuchem\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOpcja A - całkowita długość i opcja montażu\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003eDługość systemu 9,0 metrów (29,5 stóp), konfiguracja montażu panelowego  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOpcja B - opcja zatwierdzenia agencji  \u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eZatwierdzenia CSA, ATEX, IECEx (iskrobezpieczne i nieiskrzące)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne  \u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części \/ model  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-90-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRodzina produktów  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCzujnik Proximitor 3300 XL  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDługość systemu  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9,0 metrów (29,5 stóp)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp montażu  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMontaż panelowy (otwory 4-śrubowe)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17,5 Vdc do -26 Vdc (nominalnie -24 Vdc)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaksymalny pobór prądu  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp sygnału wyjściowego  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalogowe napięcie ujemne (-1 Vdc do -17 Vdc)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eImpedancja wyjściowa  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 omów  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres pomiaru liniowego  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2,0 mm (80 mils), od 0,25 mm do 2,3 mm (10 do 90 mils)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWspółczynnik skali przyrostowej (ISF)  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7,87 V\/mm (200 mV\/mil) +\/-6,5%  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaksymalna długość okablowania polowego  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 metrów (1000 stóp) ekranowanego kabla triad 3-żyłowego  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +100°C  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +105°C  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymiary (W x S x G)  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81,3 mm x 61,0 mm x 50,8 mm (W x S x G)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWaga  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e246 g (0,246 kg)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy  \u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOznaczenie zacisku  \u003c\/th\u003e\n      \u003cth\u003eOpis funkcji  \u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWejście zasilania (-17,5 Vdc do -26 Vdc)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMASA  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWspólny punkt odniesienia \/ masa systemu  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWYJŚCIE  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalogowy sygnał wyjściowy napięciowy (-1 Vdc do -17 Vdc)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne  \u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMocuj czujnik Proximitor na czystej, płaskiej powierzchni za pomocą zintegrowanej podstawy do montażu panelowego; podstawa montażowa zapewnia integralną izolację elektryczną bezpośrednio.  \u003c\/li\u003e\n  \u003cli\u003eUżywaj cynowanych, ekranowanych kabli polowych triad 3-żyłowych o przekrojach od 0,2 mm2 do 1,5 mm2 (16 AWG do 24 AWG).  \u003c\/li\u003e\n  \u003cli\u003eWłóż przewody bezpośrednio do listwy zaciskowej SpringLoc; nie są potrzebne specjalne narzędzia do wkładania ani zaciskania.  \u003c\/li\u003e\n  \u003cli\u003eOgranicz całkowitą długość okablowania polowego między czujnikiem Proximitor a systemem monitoringu do maksymalnie 305 metrów (1000 stóp), aby zapobiec tłumieniu sygnału wysokiej częstotliwości.  \u003c\/li\u003e\n  \u003cli\u003eUpewnij się, że sondy i kable przedłużające zachowują minimalny promień gięcia 25,4 mm (1,0 cala) podczas prowadzenia.  \u003c\/li\u003e\n  \u003cli\u003eDla lokalizacji zagrożonych wybuchem stosuj zatwierdzone schematy okablowania dla wymagań iskrobezpiecznych lub nieiskrzących\/niezapalających.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty  \u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNormy EMC:\u003c\/strong\u003e EN 61000-6-2 (odporność dla środowisk przemysłowych), EN 61000-6-4 (emisje dla środowisk przemysłowych)  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZgodność środowiskowa:\u003c\/strong\u003e znak CE, dyrektywa RoHS 2011\/65\/EU, zgodność z chińską RoHS (EFUP 15 lat)  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBezpieczeństwo funkcjonalne:\u003c\/strong\u003e certyfikat SIL 2 (tolerancja błędów sprzętowych HFT = 0), możliwość SIL 3 w systemach redundantnych (HFT = 1)  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZatwierdzenia do stref zagrożonych wybuchem (Opcja 05):\u003c\/strong\u003e certyfikaty CSA, ATEX i IECEx dla instalacji iskrobezpiecznych (ia) oraz nieiskrzących\/niezapalających (nA, ec) w środowiskach zagrożonych klasy I, dywizji 1\/2 oraz stref 0\/2  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519060843,"sku":"330180-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-05-3300xl-5-8-mm-proximitor-sensor-fiezfwww3ne_ce9ec8c7-1922-48ed-8e3a-ab4d790e2b9b.jpg?v=1765440127"},{"product_id":"bently-nevada-330180-51-00-3300-xl-proximitor-sensor","title":"Czujnik Bently Nevada 330180-51-00 3300 XL Proximitor","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-51-00\u003c\/strong\u003e to konfiguracja \u003cstrong\u003eczujnika Proximitor 3300 XL\u003c\/strong\u003e z kompatybilnością długości systemu 5,0 metra oraz zintegrowaną podstawą montażową na szynę DIN. Ta konkretna wersja jest oznaczona kodem opcji 00, co oznacza, że nie posiada zatwierdzeń agencji do stref zagrożenia wybuchem. Urządzenie zawiera obwody oscylatora wysokiej częstotliwości i demodulatora niezbędne do przetwarzania surowych danych przemieszczenia z kompatybilnej sondy 3300 XL 8 mm i kabla przedłużającego. Przekształca fizyczną szczelinę między końcówką sondy a materiałem docelowym na ciągły, liniowy analogowy sygnał napięciowy proporcjonalny do ruchu wału.\u003c\/p\u003e\n\u003cp\u003eŁącząc czujnik z sondą i kablem przedłużającym o całkowitej długości 5,0 metra, system pomiarowy utrzymuje liniową kalibrację w pełnym zakresie dynamicznym 2,0 mm (80 mils). Zintegrowana podstawa montażowa tej wersji zapewnia wbudowaną izolację elektryczną, zapobiegając pętlom masy i eliminując potrzebę stosowania oddzielnych płyt izolacyjnych. Sprężynowe listwy zaciskowe zapewniają pewne połączenia okablowania w terenie bez konieczności ręcznego zaciskania śrub.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOpcja 51 określa kompatybilność z całkowitą długością systemu 5,0 metra i zawiera zintegrowany montaż na szynie DIN 35 mm.\u003c\/li\u003e\n\u003cli\u003eOpcja 00 oznacza standardową konstrukcję, w której nie są wymagane specjalne certyfikaty do stref zagrożenia wybuchem.\u003c\/li\u003e\n\u003cli\u003eZintegrowane listwy zaciskowe SpringLoc ułatwiają instalacje okablowania w terenie bez specjalistycznych narzędzi.\u003c\/li\u003e\n\u003cli\u003eIzolująca podstawa montażowa zapobiega zakłóceniom elektromagnetycznym i szumom pętli masy.\u003c\/li\u003e\n\u003cli\u003eSzeroka kompatybilność ze standardowymi sondami 3300 XL 8 mm i kablami przedłużającymi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cp\u003eTen czujnik Proximitor jest używany do pomiarów drgań maszyn, położenia oraz kluczowych faz wału w standardowych środowiskach przemysłowych. Typowe instalacje obejmują:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTurbiny parowe, gazowe i wodne\u003c\/li\u003e\n\u003cli\u003eSprężarki procesowe odśrodkowe i tłokowe\u003c\/li\u003e\n\u003cli\u003ePrzemysłowe pompy wysokoprędkościowe i przekładnie\u003c\/li\u003e\n\u003cli\u003eDuże silniki elektryczne i łożyska wału generatora\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSegment opcji\u003c\/th\u003e\n\u003cth\u003eKod tego SKU\u003c\/th\u003e\n\u003cth\u003eOpis\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer części do zamówienia\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003ctd\u003eCzujnik Proximitor 3300 XL, 5,0 metrów, montaż na szynie DIN, standardowe zatwierdzenia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Całkowita długość i opcja montażu\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003eDługość systemu 5,0 metrów (16,4 stóp), montaż na szynie DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Opcja zatwierdzenia agencji\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNie wymaga zatwierdzeń\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametr\u003c\/th\u003e\n\u003cth\u003eWartość specyfikacji\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer części \/ SKU\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeria systemu\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp urządzenia\u003c\/td\u003e\n\u003ctd\u003eCzujnik Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDługość systemu\u003c\/td\u003e\n\u003ctd\u003e5,0 metrów (16,4 stóp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePodstawa montażowa\u003c\/td\u003e\n\u003ctd\u003eMontaż na szynie DIN 35 mm (Opcja 51)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMożliwość wejścia\u003c\/td\u003e\n\u003ctd\u003eAkceptuje jedną bezkontaktową sondę z serii 3300 o średnicy 5 mm lub 3300 XL o średnicy 8 mm oraz kabel przedłużający\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominalna czułość wyjściowa\u003c\/td\u003e\n\u003ctd\u003e7,87 V\/mm (200 mV\/mil) w zakresie liniowym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres liniowy\u003c\/td\u003e\n\u003ctd\u003e2,0 mm (80 mils), zaczynając około 0,25 mm (10 mils) od celu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymagania zasilania\u003c\/td\u003e\n\u003ctd\u003eWymaga -17,5 Vdc do -26 Vdc; maksymalne zużycie prądu 12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedancja wyjściowa\u003c\/td\u003e\n\u003ctd\u003eImpedancja wyjściowa nominalna 50 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd\u003e-52°C do +100°C (-62°F do +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd\u003e-52°C do +105°C (-62°F do +221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObsługa listwy zaciskowej\u003c\/td\u003e\n\u003ctd\u003ePrzewodniki 0,2 do 1,5 mm2 (16 do 24 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaksymalna odległość okablowania polowego\u003c\/td\u003e\n\u003ctd\u003e305 metrów (1000 stóp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary\u003c\/td\u003e\n\u003ctd\u003e89,4 mm x 81,3 mm x 61,0 mm (W x S x G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga\u003c\/td\u003e\n\u003ctd\u003e0,25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEtykieta zacisku\u003c\/th\u003e\n\u003cth\u003eFunkcja połączenia\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eAnalogowe wyjście sygnału przemieszczenia do systemu monitorowania\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eWspólny układ systemu \/ odniesienie masy sygnału\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003eWejście zasilania (-17,5 Vdc do -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cp\u003eUpewnij się, że podstawa montażowa jest zablokowana na standardowej szynie DIN 35 mm. Zapewnij co najmniej 3,05 mm (0,120 cala) przestrzeni pionowej nad obudową, aby ułatwić standardowe zdejmowanie z szyny. Do okablowania polowego używaj ekranowanych kabli triadowych z trzema przewodnikami, aby połączyć zaciski z monitorem. Utrzymuj okablowanie polowe w granicach maksymalnej odległości 305 metrów (1000 stóp), aby zapobiec tłumieniu sygnału wyjściowego.\u003c\/p\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eNorma certyfikacyjna\u003c\/th\u003e\n\u003cth\u003eSzczegóły\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZnak CE\u003c\/td\u003e\n\u003ctd\u003eSpełnia europejskie normy kompatybilności elektromagnetycznej (EMC) bez specjalnych ekranowanych przewodów lub obudów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519781739,"sku":"330180-51-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-51-00-3300-xl-proximitor-sensor-proximity-switch-24ni1ysosth_23365f6d-1973-456e-ab2a-a90ed88b27f2.jpg?v=1765440141"},{"product_id":"bently-nevada-330180-085-03-05-3300-xl-proximitor-sensor","title":"Czujnik Bently Nevada 330180-085-03-05 3300 XL Proximitor","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eOpcje 085 (długość 8,5 metra), 03 (kabel pancerny z osłoną złącza) oraz 05 (zatwierdzenia CSA\/ATEX\/IECEx) określają tę konfigurację czujnika \u003cstrong\u003eProximitor 3300 XL\u003c\/strong\u003e — \u003cstrong\u003e330180-085-03-05\u003c\/strong\u003e. Ten moduł czujnika działa jako kondycjoner sygnału, sterując sondą zbliżeniową prądów wirowych i przekształcając sygnał wysokoczęstotliwościowego przetwornika na proporcjonalne napięcie przemieszczenia. Analogowe wyjście napięciowe reprezentuje dokładną zmianę szczeliny między końcówką sondy a obserwowanym obszarem wału, przesyłając sygnał bezpośrednio do monitorów ochrony maszyn.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-085-03-05\u003c\/strong\u003e Konfiguracja jest specjalnie skalibrowana dla całkowitej długości systemu elektrycznego 8,5 m (Opcja 085) i obsługuje zespoły kabli przedłużających z pancerzem połączone z wbudowanymi osłonami złączy z fluoro-silikonu (Opcja 03). Zaprojektowana do instalacji w środowiskach wymagających rygorystycznych certyfikatów bezpieczeństwa wewnętrznego i przeciwwybuchowego, posiada kompleksowe międzynarodowe zatwierdzenia (Opcja 05) takie jak ATEX, IECEx i CSA. Moduł zawiera izolację elektryczną w podstawie, eliminując konieczność stosowania oddzielnych płyt izolacyjnych i ułatwiając bezpośredni montaż na szynie DIN lub panelu.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKalibrowana długość 8,5 metra (Opcja 085):\u003c\/strong\u003e Generuje dopasowane parametry impedancji skalibrowane do konfiguracji sondy zbliżeniowej i kabla o długości 8,5 m, zapobiegając błędom niedopasowania impedancji.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegracja pancerza kablowego (Opcja 03):\u003c\/strong\u003e Zaprojektowany tak, aby idealnie dopasować się do opancerzonych kabli przedłużających z wbudowanymi osłonami złączy, chroniącymi delikatne połączenia przed cieczami i cząstkami stałymi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZatwierdzenia agencji (Opcja 05):\u003c\/strong\u003e Posiada certyfikaty CSA, ATEX i IECEx do bezpiecznego użytkowania w niebezpiecznych lokalizacjach przemysłowych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOdporność na zakłócenia RFI\/EMI:\u003c\/strong\u003e Tłumi szumy elektryczne pochodzące z otaczających radioodbiorników i napędów o zmiennej częstotliwości, spełniając europejskie wymagania CE bez konieczności stosowania specjalistycznych metalowych przewodów ochronnych.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpringLoc Terminals:\u003c\/strong\u003e Wykorzystuje połączenia sprężynowe zaciskowe, które eliminują śruby i zapobiegają degradacji połączenia typowej dla drgań maszyn.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePromieniowe drgania wału i profilowanie dynamiczne turbin parowych i gazowych\u003c\/li\u003e\n\u003cli\u003ePomiar położenia osiowego i przesunięcia siły na wałach sprężarek odśrodkowych\u003c\/li\u003e\n\u003cli\u003eMonitorowanie rozszerzalności i ekscentryczności obudowy wirnika w instalacjach energetycznych\u003c\/li\u003e\n\u003cli\u003eMonitorowanie luzu łożysk i drgań konstrukcyjnych w silnikach i pompach przemysłowych o dużej mocy\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOpcja \/ segment\u003c\/th\u003e\n      \u003cth\u003eKod tego SKU\u003c\/th\u003e\n      \u003cth\u003eOpis\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer katalogowy do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-085-03-05\u003c\/td\u003e\n      \u003ctd\u003eCzujnik Proximitor 3300 XL, kompatybilność z kablem pancernym\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Opcja długości skalibrowanej\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e085\u003c\/td\u003e\n      \u003ctd\u003eDługość systemu 8,5 metra (27,9 stopy)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Opcja okablowania i ochrony\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eKabel pancerny z osłoną złącza\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Opcja zatwierdzenia agencji\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eZatwierdzenia CSA, ATEX i IECEx\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer katalogowy \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-085-03-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRodzina produktów\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp urządzenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCzujnik Proximitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDługość skalibrowana\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8,5 metra (27,9 stopy)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSygnał wyjściowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalogowe napięcie proporcjonalne (zwykle zakres -10 VDC do -24 VDC lub 7,87 V\/mm [200 mV\/mil])\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymagane zasilanie\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-24 VDC nominalne zasilanie (zwykle -18 VDC do -26 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp zakończenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eListwy zaciskowe SpringLoc (akceptują przewody do 1,5 mm2 \/ 16 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcje montażu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKonfiguracje do montażu na panelu lub na szynie DIN 35 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +100°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymiary\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81 mm x 61 mm x 51 mm (W x S x G)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWaga\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0,25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUpewnij się, że przemysłowy blok zaciskowy jest okablowany ekranowanym kablem skrętkowym, aby chronić dynamiczny analogowy sygnał przemieszczenia przed zakłóceniami elektrycznymi.\u003c\/li\u003e\n\u003cli\u003eMocno zamocuj obudowę na standardowej szynie DIN 35 mm lub przymocuj bezpośrednio do panelu. Zintegrowana izolacja podstawy eliminuje potrzebę stosowania oddzielnych nieprzewodzących płyt izolacyjnych.\u003c\/li\u003e\n\u003cli\u003eUnikaj ostrych zgięć w podłączonych sondach lub kablach przedłużających, utrzymując promień gięcia powyżej 25,4 mm (1,0 cala), aby zapobiec uszkodzeniom fizycznym kabla lub degradacji sygnału.\u003c\/li\u003e\n\u003cli\u003ePodłącz przewody polowe, wkładając śrubokręt płaski, aby zwolnić sprężynowy zacisk wewnątrz zacisku, wsuwając odizolowany przewód i zwalniając zacisk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Zatwierdzony do zastosowań w strefach zagrożenia jako iskrobezpieczny (Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc) lub beziskrowy (Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certyfikowany do pracy w strefach zagrożenia klasy I, podział 1, grupy A, B, C i D, w połączeniu z barierami bezpieczeństwa wewnętrznego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOznaczenie CE:\u003c\/strong\u003e Zgodny z europejskimi dyrektywami RFI\/EMI bez konieczności stosowania kosztownych metalowych przewodów ochronnych.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525417835,"sku":"330180-085-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-085-03-05-proximity-probe-housing-assemblies-vp0dr22uf4n_f1685e23-303f-46ea-b271-e47a4108d19f.jpg?v=1765440264"},{"product_id":"bently-nevada-330881-28-04-85-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-85-03-02 PROXPAC XL Czujnik zbliżeniowy Proximity Transducer","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-04-85-03-02\u003c\/strong\u003e: Zespół przetwornika zbliżeniowego PROXPAC XL metryczny, wyposażony w sondę 3300 XL 8 mm z wieloma aprobatami (opcja 28), adapter dystansowy 40 mm (opcja 04), długość penetracji sondy 85 mm (opcja 85), jedno złącze kablowe M20 i dwie zaślepki (opcja 03) oraz gwint montażowy 3\/4-14 NPT (opcja 02).\u003c\/p\u003e\n\n\u003cp\u003ePROXPAC XL łączy sondę zbliżeniową i czujnik Proximitor 3300 XL w jedną zintegrowaną jednostkę, eliminując potrzebę oddzielnych kabli przedłużających lub zdalnych obudów Proximitora. Obudowa wykonana jest z termoplastu polifenylenosulfidowego (PPS) wzmacnianego włóknem przewodzącym i szkłem, oferującego ochronę typu 4X i IP66 przed trudnymi warunkami przemysłowymi. Okablowanie polowe łączy się bezpośrednio z listwami zaciskowymi wewnątrz obudowy, co upraszcza instalację i konserwację maszyn obrotowych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSonda zbliżeniowa 3300 XL 8 mm z wieloma aprobatami do stref zagrożenia (opcja 28).\u003c\/li\u003e\n  \u003cli\u003eDługość adaptera dystansowego 40 mm (opcja 04) do montażu mechanicznego z przesunięciem.\u003c\/li\u003e\n  \u003cli\u003eGłębokość penetracji sondy 85 mm (opcja 85) do dotarcia do wewnętrznych obszarów docelowych.\u003c\/li\u003e\n  \u003cli\u003eDostarczany zestaw zawiera jedno złącze przewodu M20 i dwie zaślepki (opcja 03).\u003c\/li\u003e\n  \u003cli\u003eGwint montażowy 3\/4-14 NPT (opcja 02) zaprojektowany do użycia z adapterami dystansowymi.\u003c\/li\u003e\n  \u003cli\u003eSystem samodzielny eliminuje potrzebę oddzielnych kabli przedłużających między sondą a Proximitorem.\u003c\/li\u003e\n  \u003cli\u003eObudowa z termoplastu polifenylenosulfidowego (PPS) wzmacnianego włóknem przewodzącym, klasy IP66 i typu 4X.\u003c\/li\u003e\n  \u003cli\u003eListwa zaciskowa do okablowania polowego wewnątrz obudowy umożliwia bezpośrednie podłączenie do monitora.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMonitorowanie położenia osi osiowej i drgań promieniowych wału w krytycznych maszynach obrotowych.\u003c\/li\u003e\n  \u003cli\u003eBezdotykowy pomiar przemieszczenia na turbinach parowych, turbinach gazowych, sprężarkach, pompach i wentylatorach.\u003c\/li\u003e\n  \u003cli\u003eOchrona maszyn w strefach zagrożenia wymagająca instalacji czujników przeciwwybuchowych lub bezpiecznych iskrobezpiecznie.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie maszyn w trudnych warunkach, gdzie występuje wilgoć, narażenie na chemikalia lub wyładowania elektrostatyczne.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment opcji\u003c\/th\u003e\n      \u003cth\u003eKod na tym SKU\u003c\/th\u003e\n      \u003cth\u003eOpis \/ Znaczenie\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePodstawowy numer modelu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003ePrzetwornik zbliżeniowy PROXPAC XL, metryczny\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Opcja sondy i aprobat\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003eSonda 3300 XL 8 mm z wieloma aprobatami\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Opcja adaptera dystansowego\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003eDługość adaptera dystansowego 40 mm (wymiar B)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Opcja penetracji sondy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85\u003c\/td\u003e\n      \u003ctd\u003eDługość penetracji sondy 85 mm (wymiar C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Opcja złączy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eJedno złącze M20, dwie zaślepki (dostarczane jako zestaw)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Opcja gwintu montażowego\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (wymagane dla opcji adaptera dystansowego)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParametr\u003c\/th\u003e\n      \u003cth\u003eWartość \/ Specyfikacja\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProducent\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumer modelu\u003c\/td\u003e\n      \u003ctd\u003e330881-28-04-85-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeria systemu\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL (metryczny)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWejście czujnika Proximitor\u003c\/td\u003e\n      \u003ctd\u003eSonda zbliżeniowa 3300 XL 8 mm z kablem o długości 1 metra zamontowana w tulei sondy\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZakres liniowy\u003c\/td\u003e\n      \u003ctd\u003e2,0 mm (80 mil), od około 0,25 mm do 2,3 mm (10 mil do 90 mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZakres napięcia wyjściowego\u003c\/td\u003e\n      \u003ctd\u003e-1 Vdc do -17 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWspółczynnik skali przyrostowej (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7,87 V\/mm (200 mV\/mil) +\/-5% w zakresie liniowym\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWymagania zasilania systemu\u003c\/td\u003e\n      \u003ctd\u003eWymaga -17,5 Vdc do -26 Vdc (bez barier) przy maksymalnym poborze 12 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZalecane ustawienie przerwy\u003c\/td\u003e\n      \u003ctd\u003e1,27 mm (50 mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOpór wyjściowy\u003c\/td\u003e\n      \u003ctd\u003e50 omów\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePasmo przenoszenia\u003c\/td\u003e\n      \u003ctd\u003e0 do 10 kHz: +0, -3 dB (z okablowaniem polowym do 305 metrów)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimalny rozmiar celu\u003c\/td\u003e\n      \u003ctd\u003eŚrednica 15,2 mm (0,6 cala) (płaski cel)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZalecana średnica wałka\u003c\/td\u003e\n      \u003ctd\u003eMinimalna zalecana średnica 76,2 mm (3,0 cala), absolutne minimum 50,8 mm (2,0 cala)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMateriał końcówki sondy\u003c\/td\u003e\n      \u003ctd\u003ePolifenylenosulfid (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMateriał obudowy sondy\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTyp kabla sondy\u003c\/td\u003e\n      \u003ctd\u003eKabel trójosiowy 1 metr, 75 omów, izolowany fluoroetylenopropylenem (FEP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZłącze sondy\u003c\/td\u003e\n      \u003ctd\u003eZłocone mosiężne złącze ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMateriał obudowy\u003c\/td\u003e\n      \u003ctd\u003eOdporna na promieniowanie ultrafioletowe (UV), termoplastyczna polifenylenosulfidowa (PPS) z włóknami przewodzącymi\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eKlasa szczelności obudowy\u003c\/td\u003e\n      \u003ctd\u003eIP66 i Typ 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZakres temperatury sondy\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +177°C (praca)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZakres temperatur obudowy i czujnika\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +100°C (praca)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZakres temperatur przechowywania\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +105°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWilgotność względna\u003c\/td\u003e\n      \u003ctd\u003e100% kondensacja, nie do zanurzenia, gdy złącza są chronione\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMateriał pierścienia uszczelniającego tulei\u003c\/td\u003e\n      \u003ctd\u003eNeopren\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMateriał wkładki uziemiającej\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUziemienie: Wewnętrzna wkładka uziemiająca w obudowie zapewnia ścieżkę do rozładowania ładunków statycznych. Upewnij się, że obudowa jest prawidłowo uziemiona przez strukturę montażową lub dedykowane połączenie uziemiające.\u003c\/li\u003e\n  \u003cli\u003eUszczelnienie: Użyj dostarczonego pierścienia uszczelniającego z neoprenu między tuleją a obudową. Na gwintach montażowych zastosuj odpowiedni uszczelniacz, aby zapobiec przedostawaniu się wilgoci.\u003c\/li\u003e\n  \u003cli\u003ePołączenia przewodów: Prowadź okablowanie polowe przez dostarczony przyłącz M20. Uszczelnij nieużywane wejścia przewodów zaślepkami dołączonymi w zestawie, aby zachować klasę szczelności IP66.\u003c\/li\u003e\n  \u003cli\u003ePrzerwa zbliżeniowa: Ustaw nominalną przerwę między końcówką sondy a celem na wałku na 1,27 mm (50 mil) w celu uzyskania pracy wyśrodkowanej w zakresie liniowym 2,0 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eKlasyfikacja elektryczna: Zgodność z europejską marką CE\u003c\/li\u003e\n  \u003cli\u003eOchrona środowiskowa: Obudowa o klasie szczelności IP66 (potwierdzona raportem BASEEFA)\u003c\/li\u003e\n  \u003cli\u003eZatwierdzenia do stref zagrożonych: Wielokrotne zatwierdzenia (Opcja 28) obejmujące normy północnoamerykańskie (CSA), europejskie (ATEX) oraz międzynarodowe (IECEx) dla stref 0, 1, 2, Klasy I Dywizji 1 oraz Klasy I Dywizji 2 w środowiskach zagrożonych.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525647211,"sku":"330881-28-04-85-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-85-03-02-proximity-transducer-wgeeb2buii4_06b4432f-feb8-41e9-bc3c-350808d827ff.jpg?v=1765440269"},{"product_id":"bently-nevada-330881-28-04-145-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-145-03-02 PROXPAC XL Przetwornik zbliżeniowy","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eOpcja 28 (sonda 3300 XL 8 mm z wieloma aprobatami) oraz Opcja 04 (adapter dystansowy 40 mm) definiują metryczną konfigurację tego specjalistycznego przetwornika zbliżeniowego PROXPAC XL — \u003cstrong\u003e330881-28-04-145-03-02\u003c\/strong\u003eZintegrowany zestaw posiada długość penetracji sondy 145 mm (Opcja 145) chronioną trwałą tuleją, konfigurację montażową z gwintem 3\/4-14 NPT (Opcja 02) oraz zestaw złączy z jednym złączem przewodu M20 i dwiema zaślepkami (Opcja 03).\u003c\/p\u003e\n\u003cp\u003eŁącząc wysokoprecyzyjną sondę zbliżeniową 3300 XL 8 mm i zintegrowany czujnik Proximitor 3300 XL w jednej, samodzielnej obudowie z polifenylenosulfidu (PPS), ten projekt eliminuje potrzebę oddzielnych kabli przedłużających i skrzynek pośrednich. To metryczne rozwiązanie upraszcza instalację i zapewnia solidną ochronę mechaniczną oraz środowiskową dla krytycznego monitoringu maszyn wirujących, czyniąc je bardzo skutecznym w trudnych warunkach przemysłowych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOpcja 28 integracji sondy łączy sondę zbliżeniową 3300 XL 8 mm z wieloma aprobatami bezpośrednio w obudowie przetwornika.\u003c\/li\u003e\n\u003cli\u003eOpcja 04 adaptera dystansowego zapewnia wymiar dystansu 40 mm dla precyzyjnego pozycjonowania podczas instalacji.\u003c\/li\u003e\n\u003cli\u003eOpcja 145 penetracji oznacza głębokość tulei 145 mm, umożliwiającą skuteczne dotarcie do wewnętrznych punktów pomiarowych.\u003c\/li\u003e\n\u003cli\u003eOpcja 03 zestaw złączy dostarcza jedno złącze przewodu M20 i dwie zaślepki, upraszczając uszczelnienie wejścia kabla.\u003c\/li\u003e\n\u003cli\u003eOpcja 02 gwint montażowy określa połączenie 3\/4-14 NPT, spełniające mechaniczne wymagania dla wsparcia adaptera dystansowego.\u003c\/li\u003e\n\u003cli\u003eObudowa z termoplastycznego PPS z włóknem szklanym i przewodzącym wzmacnia ochronę środowiskową typu 4X i IP66 oraz rozprasza ładunki elektrostatyczne.\u003c\/li\u003e\n\u003cli\u003eZintegrowany układ czujnika Proximitor eliminuje konieczność okablowania polowego dla kabli przedłużających i oddzielnych obudów nadajnika.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cp\u003eTypowe zastosowania obejmują:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePomiar drgań wału i położenia osiowego na turbinach parowych, turbinach gazowych i dużych sprężarkach przemysłowych.\u003c\/li\u003e\n\u003cli\u003eMonitorowanie drgań promieniowych i przemieszczeń na szybkorotujących maszynach w strefach zagrożonych, wymagających wielu regionalnych certyfikatów.\u003c\/li\u003e\n\u003cli\u003eInstalacje petrochemiczne, energetyczne i uzdatniania wody o wysokich wymaganiach, gdzie kluczowa jest odporność na bezpośrednie działanie i chemikalia.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSegment opcji\u003c\/th\u003e\n\u003cth\u003eKod na tym SKU\u003c\/th\u003e\n\u003cth\u003eOpis \/ Znaczenie\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-04-145-03-02\u003c\/td\u003e\n\u003ctd\u003ePrzetwornik zbliżeniowy PROXPAC XL, metryczny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Opcja sondy i aprobat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003eSonda 3300 XL 8 mm z wieloma aprobatami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Opcja adaptera dystansowego (wymiar B)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eDługość adaptera dystansowego 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Opcja penetracji sondy (wymiar C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003ctd\u003eDługość penetracji sondy 145 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Opcja złączy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eJedno złącze M20, dwie zaślepki\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpcja gwintu montażowego E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (wymagane dla opcji adaptera dystansowego)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-04-145-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzetwornik zbliżeniowy PROXPAC XL (metryczny)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp sondy integralnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSonda zbliżeniowa 3300 XL 8 mm z kablem 1-metrowym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał obudowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOdporne na promieniowanie UV, wzmacniany włóknem szklanym polifenylenosulfid (PPS) termoplastyczny zawierający włókna przewodzące\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał tulei\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał uszczelki tulei\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeopren\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał wkładki uziemiającej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał izolacji drgań\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBardzo miękki silikon komórkowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał etykiety pokrywy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBłyszczący biały poliester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoc wejściowa przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWymaga -17,5 Vdc do -26 Vdc przy maksymalnym prądzie 12 mA (bez barier bezpieczeństwa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres liniowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePasmo przenoszenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do 10 kHz: +0, -3 dB przy okablowaniu do 305 metrów (1000 stóp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalny rozmiar celu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eŚrednica 15,2 mm (0,6 cala) (płaski cel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalna średnica wału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50,8 mm (2,0 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZalecana średnica wału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimalna średnica wału 76,2 mm (3,0 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (sonda)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C do +177°C (-62°F do +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy (obudowa i czujnik)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C do +100°C (-62°F do +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C do +105°C (-62°F do +221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWilgotność względna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% kondensująca, nie do zanurzenia, gdy złącza są chronione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOchrona środowiskowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTyp 4X i IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePraktyki uziemienia:\u003c\/strong\u003e Obudowa PROXPAC XL musi być prawidłowo uziemiona za pomocą wbudowanej wkładki uziemiającej i płyty mocującej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZapobieganie wilgoci:\u003c\/strong\u003e Upewnij się, że wszystkie przewody są całkowicie uszczelnione, aby zapobiec migracji wilgoci przez przewód do plastikowej obudowy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimity temperatury:\u003c\/strong\u003e Nie narażaj końcówki sondy na temperatury poniżej -34°C (-29°F), aby zapobiec przedwczesnej awarii wewnętrznego uszczelnienia ciśnieniowego.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWsparcie tulei:\u003c\/strong\u003e Jeśli łączna długość adaptera dystansowego (B) i penetracji (C) przekracza 305 mm (12,0 cala), zastosuj dodatkowe zewnętrzne wsparcie tulei w pobliżu sondy, aby zwiększyć sztywność zespołu i wyeliminować rezonansowe drgania.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOznakowanie CE:\u003c\/strong\u003e Zgodność z obowiązującymi dyrektywami Unii Europejskiej.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStopień ochrony IP:\u003c\/strong\u003e Obudowa oceniona na IP66 (zweryfikowane przez BASEEFA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty do stref zagrożonych wybuchem (CNRTLUS):\u003c\/strong\u003e Klasa I, Strefa 0: AEx\/Ex ia IIC T4\/T5 Ga; Klasa I, Grupy A, B, C, D; Klasa II, Grupy E, F, G; Klasa III. Klasa I, Strefa 2: AEx\/Ex nA IIC T5...T1 Gc; Klasa I, Dywizja 2, Grupy A, B, C, D; Klasa I, Strefa 2: AEx\/Ex ec IIC T5...T1 Gc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertyfikaty do stref zagrożonych wybuchem (ATEX\/IECEx):\u003c\/strong\u003e II 1 G, Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc. II 3 G, Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527285611,"sku":"330881-28-04-145-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-145-03-02-proxpac-xl-proximity-transducer-p5pfxa0yjvs_921e9da5-5db0-492f-8cf9-8667e4385c76.jpg?v=1765440296"},{"product_id":"bently-nevada-330881-28-04-150-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-150-06-02 PROXPAC XL Czujnik zbliżeniowy Proximity Transducer","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eOpcja 28 (sonda 3300 XL 8 mm z wieloma aprobatami) oraz opcja 150 (rękaw penetracji sondy 150 mm) określają tę unikalną konfigurację PROXPAC XL — \u003cstrong\u003e330881-28-04-150-06-02\u003c\/strong\u003eTen zintegrowany zespół przetwornika posiada adapter dystansowy 40 mm oraz złącza NPT z reduktorem ze stali nierdzewnej, tworząc samodzielny system monitoringu eliminujący zewnętrzne kable przedłużające. Montując czujnik Proximitor 3300 XL bezpośrednio w pokrywie obudowy, okablowanie polowe łączy się bezpośrednio z monitorami maszyn, upraszczając całą instalację.\u003c\/p\u003e\n\n\u003cp\u003eW przeciwieństwie do podstawowych opcji bez mechanicznego dystansu, ta metryczna wersja wykorzystuje gwint montażowy 3\/4-14 NPT (Opcja 02), który jest mechanicznie niezbędny do podparcia zintegrowanego adaptera dystansowego 40 mm (Opcja 04). Obudowa wykonana jest z zaawansowanego termoplastu polifenylenosiarczku (PPS) wzmacnianego włóknem szklanym, zawierającego przewodzące włókna, które wzmacniają zewnętrzny zespół i chronią wnętrze przed agresywnym środowiskiem chemicznym i elektrostatycznym.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOpcja 28 integruje sondę zbliżeniową 3300 XL 8 mm z wieloma aprobatami bezpieczeństwa.\u003c\/li\u003e\n\u003cli\u003eOpcja 04 zapewnia metryczny adapter dystansowy 40 mm ułatwiający integrację z obudową maszyny.\u003c\/li\u003e\n\u003cli\u003eOpcja 150 oferuje długość penetracji sondy 150 mm dla precyzyjnego ustawienia szczeliny.\u003c\/li\u003e\n\u003cli\u003eOpcja 06 zawiera jedno złącze 3\/4-14 NPT, jeden reduktor ze stali nierdzewnej 3\/4-14 NPT do 1-1\/2-14 NPT oraz dwie zaślepki.\u003c\/li\u003e\n\u003cli\u003eOpcja 02 zapewnia gwint montażowy 3\/4-14 NPT wymagany dla stabilności strukturalnej adaptera dystansowego.\u003c\/li\u003e\n\u003cli\u003eZaawansowana obudowa z termoplastu polifenylenosiarczku (PPS) wzmacnianego włóknem szklanym zapobiega gromadzeniu się ładunków elektrostatycznych.\u003c\/li\u003e\n\u003cli\u003eW pełni samodzielna konstrukcja eliminuje potrzebę oddzielnych obudów Proximitor i kabli przedłużających.\u003c\/li\u003e\n\u003cli\u003eUszczelnienie środowiskowe NEMA Typ 4X i IP66 spełnia wymagania chemiczne i morskie.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitorowanie pozycji osiowej i drgań wału w trudnych warunkach przemysłowych.\u003c\/li\u003e\n\u003cli\u003eMiejsca o surowych warunkach środowiskowych, gdzie oddzielna ochrona Proximitor jest niepraktyczna.\u003c\/li\u003e\n\u003cli\u003eMontaż bezpośrednio na maszynie, gdzie okablowanie musi prowadzić bezpośrednio do szaf monitorujących.\u003c\/li\u003e\n\u003cli\u003eInstalacje petrochemiczne, energetyczne i turbiny gazowe wymagające certyfikowanego sprzętu iskrobezpiecznego.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSegment opcji\u003c\/th\u003e\n\u003cth\u003eKod tego SKU\u003c\/th\u003e\n\u003cth\u003eOpis \/ wybrana opcja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-04-150-06-02\u003c\/td\u003e\n\u003ctd\u003ePrzetwornik zbliżeniowy PROXPAC XL, metryczny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Opcja sondy i aprobat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003eSonda 3300 XL 8 mm z wieloma aprobatami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Opcja adaptera dystansowego (wymiar B)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eDługość adaptera dystansowego 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Opcja długości penetracji sondy (wymiar C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003eDługość penetracji sondy 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Opcja złączy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eJedno złącze 3\/4-14 NPT, jeden reduktor ze stali nierdzewnej 3\/4-14 NPT do 1-1\/2-14 NPT oraz dwie zaślepki\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Opcja gwintu montażowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eGwint 3\/4-14 NPT (wymagany przy zamawianiu adaptera dystansowego)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametr\u003c\/th\u003e\n\u003cth\u003eWartość specyfikacji\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer modelu\u003c\/td\u003e\n\u003ctd\u003e330881-28-04-150-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp produktu\u003c\/td\u003e\n\u003ctd\u003ePrzetwornik zbliżeniowy PROXPAC XL (metryczny)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWejście czujnika Proximitor\u003c\/td\u003e\n\u003ctd\u003eSonda zbliżeniowa 3300 XL 8 mm z kablem o długości 1 metra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymagania zasilania\u003c\/td\u003e\n\u003ctd\u003eWymaga -17,5 Vdc do -26 Vdc bez barier przy maksymalnym prądzie 12 mA; -23 Vdc do -26 Vdc z barierami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCzułość zasilania\u003c\/td\u003e\n\u003ctd\u003eZmiana napięcia wyjściowego mniejsza niż 2 mV na zmianę napięcia wejściowego o 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpór wyjściowy\u003c\/td\u003e\n\u003ctd\u003e50 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKompatybilność okablowania polowego\u003c\/td\u003e\n\u003ctd\u003e0,2 do 1,5 mm2 (16 do 24 AWG), zalecany ekranowany trójprzewodowy kabel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres liniowy\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils), zaczynając około 0,25 mm (10 mils) od celu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZalecane ustawienie szczeliny\u003c\/td\u003e\n\u003ctd\u003e1,27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWspółczynnik skali przyrostowej (ISF)\u003c\/td\u003e\n\u003ctd\u003e7,87 V\/mm (200 mV\/mil) +\/-5% standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOdchylenie systemu (DSL)\u003c\/td\u003e\n\u003ctd\u003eMniej niż +\/-0,025 mm (+\/-1 mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał obudowy\u003c\/td\u003e\n\u003ctd\u003eOdporne na promieniowanie ultrafioletowe (UV), wzmacniane włóknem szklanym termoplastyczne poli(tereftalan fenylenu) (PPS) zawierające włókna przewodzące\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał tulei i łańcuch zabezpieczający\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZewnętrzna tuleja i śruby mocujące\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał uszczelki tulei\u003c\/td\u003e\n\u003ctd\u003eNeopren\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał wkładki uziemiającej\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał izolacji drgań\u003c\/td\u003e\n\u003ctd\u003eBardzo miękki silikon komórkowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał etykiety pokrywy\u003c\/td\u003e\n\u003ctd\u003eBłyszczący biały poliester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura pracy (obudowa sondy i Proximitor)\u003c\/td\u003e\n\u003ctd\u003e-52°C do +100°C (-62°F do +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura przechowywania\u003c\/td\u003e\n\u003ctd\u003e-52°C do +105°C (-62°F do +221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres temperatury sondy\u003c\/td\u003e\n\u003ctd\u003e-52°C do +177°C (-62°F do +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUszczelnienie środowiskowe\u003c\/td\u003e\n\u003ctd\u003eTyp 4X, IP66 (potwierdzone przez BASEEFA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWilgotność względna\u003c\/td\u003e\n\u003ctd\u003e100% kondensacji, nie do zanurzenia, gdy złącza są chronione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElement interfejsu\u003c\/th\u003e\n\u003cth\u003eSzczegóły \/ wsparcie\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZaciski okablowania polowego\u003c\/td\u003e\n\u003ctd\u003eBezpośrednie połączenie wewnątrz pokrywy obudowy; obsługuje przewody polowe do 1,5 mm2 (16 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaksymalna odległość okablowania w terenie\u003c\/td\u003e\n\u003ctd\u003e305 metrów (1000 stóp) między przetwornikiem a monitorem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZintegrowane połączenia kablowe\u003c\/td\u003e\n\u003ctd\u003eWstępnie poprowadzone wewnętrzne połączenie eliminujące standardowe zewnętrzne kable przedłużające ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cp\u003eUpewnij się, że obudowa jest solidnie zamontowana. Gwint montażowy 3\/4-14 NPT (Opcja 02) musi być całkowicie wkręcony, aby zapewnić integralność konstrukcyjną adaptera dystansowego. Przestrzegaj zalecanych przez producenta limitów momentu dokręcania: zastosuj 29,5 N·m (260 in-lb) do nakrętki zabezpieczającej oraz 39,3 N·m (350 in-lb) do nakrętki blokującej tuleję sondy. Upewnij się, że uszczelki, zaślepki i złączki są prawidłowo zamontowane, aby zapobiec przedostawaniu się wilgoci przez przewody do wnętrza obudowy.\u003c\/p\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZgodność z europejską normą CE\u003c\/li\u003e\n\u003cli\u003eStopień ochrony IP66 potwierdzony przez BASEEFA (Raport T07\/0709)\u003c\/li\u003e\n\u003cli\u003eZatwierdzenia do stref zagrożonych wybuchem (Opcja 28): Bezpieczne iskrobezpieczne (Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc) oraz iskrobezpieczne\/ze zwiększonym bezpieczeństwem (Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc) do środowisk strefowych\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527875435,"sku":"330881-28-04-150-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-150-06-02-proxpac-xl-housing-sxwhfwprmw2_a794ff79-407c-4b0e-bce5-bbcb8cda6198.jpg?v=1765440306"},{"product_id":"bently-nevada-330180-x1-05mod-145193-01-3300-xl-proximitor-sensor","title":"Czujnik Bently Nevada 330180-X1-05MOD:145193-01 3300 XL Proximitor","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-X1-05MOD:145193-01\u003c\/strong\u003e: Ten czujnik Proximitor 3300 XL jest skonfigurowany z opcją X1 do montażu na szynie DIN, opcją 05 dla wielu zatwierdzeń do stref zagrożenia wybuchem oraz jest kalibrowany na zamówienie w ramach modyfikacji 145193-01 dla niestandardowych materiałów docelowych.\u003c\/p\u003e\n\u003cp\u003eW przeciwieństwie do standardowych wariantów 330180 skalibrowanych dla stali AISI 4140, ten czujnik Proximitor zawiera fabryczne układy rekalkulacji, które utrzymują precyzyjną liniowość pomiaru prądów wirowych na określonych niestandardowych stopach. Integruje oscylator i elektronikę detekcyjną do kondycjonowania sygnałów sondy zbliżeniowej na ciągły sygnał przemieszczenia, bezpośrednio kompatybilny z monitorami ochrony maszyn, takimi jak system Bently Nevada 3500.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObudowa do montażu na szynie DIN określona przez opcję X1 dla bezpiecznego montażu w obudowie elektrycznej\u003c\/li\u003e\n\u003cli\u003eWiele zatwierdzeń do stref zagrożenia wybuchem w ramach opcji 05, w tym standardy bezpieczeństwa iskrobezpiecznego ATEX, IECEx i CSA\u003c\/li\u003e\n\u003cli\u003eIndywidualna kalibracja materiału docelowego w ramach modyfikacji inżynieryjnej Bently Nevada MOD 145193-01\u003c\/li\u003e\n\u003cli\u003eKonwersja sygnałów RF prądów wirowych na ciągły sygnał napięciowy proporcjonalny do odległości od celu\u003c\/li\u003e\n\u003cli\u003eBezproblemowa integracja z sondami zbliżeniowymi 3300 XL 5mm\/8mm o długości 9 m oraz kablami przedłużającymi\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitorowanie drgań promieniowych wału i położenia osiowego w szybkozależnych maszynach przemysłowych\u003c\/li\u003e\n\u003cli\u003eCiężkie zastosowania przemysłowe w energetyce, przemyśle naftowym i gazowym, petrochemicznym oraz chemicznym\u003c\/li\u003e\n\u003cli\u003eSpecjalistyczna analiza dynamiki wirników w turbinach wykorzystujących niestandardowe materiały wałów\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSegment opcji\u003c\/th\u003e\n\u003cth\u003eKod na tym SKU\u003c\/th\u003e\n\u003cth\u003eOpis\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer części do zamówienia\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145193-01\u003c\/td\u003e\n\u003ctd\u003eCzujnik Proximitor 3300 XL 5mm\/8mm, system 9 metrów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCałkowita długość i montaż\u003c\/td\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eModyfikacja, montaż na szynie DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZatwierdzenie agencji\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eWiele zatwierdzeń (CSA, ATEX, IECEx iskrobezpieczne)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer modyfikacji\u003c\/td\u003e\n\u003ctd\u003eMOD:145193\u003c\/td\u003e\n\u003ctd\u003eRodzina modyfikacji rekalkibracji materiału docelowego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpcja materiałowa\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eOpcja 01 w ramach modyfikacji niestandardowej 145193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDane techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametr\u003c\/th\u003e\n\u003cth\u003eSpecyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145193-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp urządzenia\u003c\/td\u003e\n\u003ctd\u003eCzujnik Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKompatybilność systemu\u003c\/td\u003e\n\u003ctd\u003eSystemy sond zbliżeniowych 3300 XL 5mm\/8mm o długości 9 m oraz kable przedłużające\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp montażu\u003c\/td\u003e\n\u003ctd\u003eMontaż na szynie DIN (opcja X1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSygnał wyjściowy\u003c\/td\u003e\n\u003ctd\u003eLiniowy analogowy sygnał 7,87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres liniowy\u003c\/td\u003e\n\u003ctd\u003e10 do 90 mil (0,25 do 2,30 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymagania zasilania\u003c\/td\u003e\n\u003ctd\u003eWymaga zasilania -24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura pracy\u003c\/td\u003e\n\u003ctd\u003e-35°C do +85°C (-31°F do +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymiary\u003c\/td\u003e\n\u003ctd\u003e81,3 mm x 61,2 mm x 103,1 mm (W x S x G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga\u003c\/td\u003e\n\u003ctd\u003e0,25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003eFunkcja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eWspólny \/ masa obwodu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eSygnał wyjściowy przemieszczenia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVTG (PROX)\u003c\/td\u003e\n\u003ctd\u003eZasilanie (-24 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZłącze koncentryczne\u003c\/td\u003e\n\u003ctd\u003ePołączenie z kablem przedłużającym 3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMocować solidnie na standardowej szynie DIN 35 mm w obudowie chronionej środowiskowo.\u003c\/li\u003e\n\u003cli\u003eZadbać o odpowiednią izolację elektryczną i uziemienie ekranu, aby zapobiec zakłóceniom zewnętrznym.\u003c\/li\u003e\n\u003cli\u003ePodłączyć kabel koncentryczny z kabla przedłużającego do złącza koncentrycznego Proximitor, dokręcając ręcznie.\u003c\/li\u003e\n\u003cli\u003eUtrzymywać odpowiednią szczelinę między sondą a celem, odpowiadającą zakresowi liniowemu 10 do 90 mil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\/IECEx iskrobezpieczne (opcja 05)\u003c\/li\u003e\n\u003cli\u003eCSA Klasa I, Dywizja 1, Grupy A, B, C, D (opcja 05)\u003c\/li\u003e\n\u003cli\u003eZgodność z CE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528006507,"sku":"330180-X1-05 MOD: 145193-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145193-01-3300-xl-proximitor-sensor-5w11ezz4jnd_f4825ce2-814e-4ef2-a538-253f1ab12228.jpg?v=1765440307"},{"product_id":"bently-nevada-330880-16-00-060-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-16-00-060-03-02 PROXPAC XL Czujnik zbliżeniowy Proximity Transducer","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330880-16-00-060-03-02\u003c\/strong\u003e to konfiguracja zintegrowanego przetwornika zbliżeniowego PROXPAC XL English z wbudowaną sondą 3300 XL 8 mm bez zatwierdzeń do stref zagrożenia (opcja 16), bez adaptera dystansowego (opcja 00), z penetracją sondy 6,0 cala (opcja 060), specjalistycznymi reduktorami NPT (opcja 03) oraz gwintem montażowym rękawa zewnętrznego 3\/4-14 NPT (opcja 02). Ta zintegrowana jednostka łączy sondę zbliżeniową 3300 XL 8 mm i powiązany czujnik Proximitor bezpośrednio w jedną, samodzielną obudowę ochronną, eliminując potrzebę stosowania zewnętrznego kabla przedłużającego lub oddzielnej obudowy zdalnej. Okablowanie polowe z monitora systemu kończy się bezpośrednio w obszarze połączeniowym obudowy, zmniejszając zajmowaną powierzchnię, złożoność instalacji oraz potencjalne punkty awarii kabli.\u003c\/p\u003e\n\n\u003cp\u003eW przeciwieństwie do konfiguracji do stref zagrożenia, takich jak opcja 28 (z wieloma zatwierdzeniami agencji dla stref bezpiecznych i nieiskrzących), konfiguracja opcja 16 jest zoptymalizowana pod kątem ekonomicznej implementacji w przemysłowych środowiskach niebezpiecznych. Rękaw penetracyjny o długości 6,0 cala (opcja 060) umożliwia bezpośrednie zanurzenie w obudowach maszyn, a wewnętrzne uszczelki Neoprenowe O-ring zapewniają ochronę na poziomie IP66. Wytrzymała obudowa z polifenylenosulfidu (PPS) wzmocnionego włóknami szklanymi i przewodzącymi zwiększa wytrzymałość obudowy i skutecznie rozprasza ładunki elektrostatyczne, co czyni zestaw odpowiednim do surowych warunków przemysłowych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZintegrowany projekt przetwornika zbliżeniowego\u003c\/strong\u003e: Łączy sondę 3300 XL 8 mm i czujnik Proximitor w jedną, samodzielną jednostkę, eliminując potrzebę stosowania kabli przedłużających.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKonfiguracja sondy opcja 16\u003c\/strong\u003e: Wyposażona w standardową sondę 3300 XL 8 mm bez zatwierdzeń agencji, idealna do ogólnego monitoringu w środowiskach niebezpiecznych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRękaw penetracyjny o długości 6,0 cala (opcja 060)\u003c\/strong\u003e: Zapewnia sztywną głębokość zanurzenia sondy 6,0 cala (152 mm) w obudowie maszyny, regulowaną w zakresie plus minus 12,7 mm (0,5 cala).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eObudowa z zaawansowanego termoplastiku PPS\u003c\/strong\u003e: Wykonana z polifenylenosulfidu (PPS) wzmocnionego włóknami szklanymi i przewodzącymi, maksymalizująca wytrzymałość obudowy i zdolność do rozpraszania ładunków elektrostatycznych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZestaw montażowy opcja 03\u003c\/strong\u003e: Zawiera jedno złącze 3\/4-14 NPT, reduktor ze stali nierdzewnej 3\/4-14 NPT do 1\/2-14 NPT oraz dwie zaślepki ułatwiające prowadzenie przewodów w terenie.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKlasa ochrony 4X i IP66\u003c\/strong\u003e: Zapewnia ochronę przed kurzem i strumieniami wody pod wysokim ciśnieniem, gwarantując bezpieczeństwo wewnętrznych komponentów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePołączony monitoring drgań promieniowych wału i położenia osiowego wału w maszynach obrotowych.\u003c\/li\u003e\n  \u003cli\u003eInstalacje w ograniczonej przestrzeni obudowy turbiny lub ramy sprężarki, gdzie zdalne obudowy Proximitor są niepraktyczne.\u003c\/li\u003e\n  \u003cli\u003eSurowe środowiska przemysłowe wymagające fizycznej ochrony obudowy przed myciem wodą i przedostawaniem się kurzu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment opcji\u003c\/th\u003e\n      \u003cth\u003eKod na tym SKU\u003c\/th\u003e\n      \u003cth\u003eOpis \/ Znaczenie\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-16-00-060-03-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Przetwornik Zbliżeniowy, wersja angielska\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja sondy i zatwierdzeń A\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n      \u003ctd\u003eSonda 3300 XL 8 mm bez zatwierdzeń\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja adaptera dystansowego B\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eBrak adaptera dystansowego\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja penetracji sondy C\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003eDługość penetracji 6,0 cala (152 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja złączy D\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eJedno złącze 3\/4-14 NPT, jedno reduktor SST 3\/4-14 NPT do 1\/2-14 NPT oraz dwie zaślepki\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja gwintu montażowego E\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (wymagane przy montażu zespołu zewnętrznej tulei)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Numer części\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-16-00-060-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp systemu przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Zintegrowany Przetwornik Zbliżeniowy\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp sondy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSonda zbliżeniowa 3300 XL 8 mm (kabel wewnętrzny 1 metr)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres liniowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2,0 mm (80 mils), zaczynając od 0,25 mm (10 mils) od celu\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWspółczynnik skali\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7,87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymagania zasilania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17,5 V DC do -26 V DC przy maksymalnym prądzie 12 mA (bez barier)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePasmo przenoszenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 do 10 kHz: +0, -3 dB (z okablowaniem do 305 m)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał końcówki sondy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolifenylenosulfid (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał obudowy sondy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał obudowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolifenylenosulfid (PPS) wzmacniany włóknem szklanym, odporny na UV z włóknami przewodzącymi\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTuleja i łańcuch zabezpieczający\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał uszczelki O-ring tulei\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeopren\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKlasa ochrony środowiskowej obudowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTyp 4X i IP66 (potwierdzone raportem BASEEFA T07\/0709)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy sondy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +177°C (-62°F do +351°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy obudowy i czujnika\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +100°C (-62°F do +212°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWytrzymałość obudowy na uderzenia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWytrzymuje dwa uderzenia o energii 4 dżuli w temperaturach -39°C i +115°C (certyfikat BASEEFA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReguluj szczelinę sondy, obracając gwintowaną tuleję sondy w gwintach montażowych obudowy maszyny.\u003c\/li\u003e\n  \u003cli\u003eGwint montażowy to 3\/4-14 NPT (Opcja 02) i powinien być odpowiednio uszczelniony standardowym uszczelniaczem do gwintów.\u003c\/li\u003e\n  \u003cli\u003eStandardowy moment dokręcania nakrętki blokującej zewnętrznej tulei wynosi 39,3 N·m (350 in-lb).\u003c\/li\u003e\n  \u003cli\u003eUpewnij się, że neoprenowa uszczelka O-ring jest odpowiednio nasmarowana i osadzona między tuleją sondy a obudową, aby utrzymać klasę szczelności IP66.\u003c\/li\u003e\n  \u003cli\u003eUnikaj metalicznych zakłóceń z boku i z tyłu na końcówce sondy, zachowując odpowiedni odstęp od otaczających ścian maszyn.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eZgodność z FCC Część 15\u003c\/li\u003e\n  \u003cli\u003eZgodność z oznakowaniem CE\u003c\/li\u003e\n  \u003cli\u003eDyrektywa EMC 2014\/30\/UE (normy: EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003eDyrektywa RoHS 2011\/65\/UE\u003c\/li\u003e\n  \u003cli\u003eZatwierdzenia do stref zagrożonych: Opcja 16 niezatwierdzona (przeznaczona wyłącznie do użytku w miejscach niezagrożonych)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528891243,"sku":"330880-16-00-060-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-16-00-060-03-02-proximity-transducer-ql3pkwfhtu3_3a48fc5a-034a-40fe-8071-79835ef56ffb.jpg?v=1765440317"},{"product_id":"bently-nevada-330880-00-20-038-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-00-20-038-00-02 PROXPAC XL Czujnik zbliżeniowy Proximity Transducer","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eOpcja 00 (bez sondy; tylko czujnik Proximitor) i opcja 20 (adapter dystansowy 2,0 cala) określają tę zintegrowaną konfigurację przetwornika zbliżeniowego 3300 XL PROXPAC - \u003cstrong\u003e330880-00-20-038-00-02\u003c\/strong\u003eZaprojektowany z długością penetracji sondy 3,8 cala (opcja 038), zespół zapewnia samodzielne rozwiązanie monitorujące, umieszczając czujnik 3300 XL Proximitor bezpośrednio w pokrywie obudowy, eliminując potrzebę oddzielnych obudów Proximitor i kabli przedłużających. Ten model nie zawiera zestawu montażowego tulei sondy (opcja 00) i posiada standardowy gwint montażowy 3\/4-14 NPT (opcja 02) dla bezpiecznej instalacji mechanicznej.\u003c\/p\u003e\n\u003cp\u003eŁącząc czujnik i obudowę zakończeniową w jedną, kompaktową jednostkę, ta konfiguracja zmniejsza złożoność okablowania i instalacji w terenie. W przeciwieństwie do konfiguracji zawierających zintegrowaną sondę 3300 XL 8 mm lub posiadających zatwierdzenia do stref zagrożonych wybuchem, model 330880-00-20-038-00-02 służy jako niezatwierdzony zamiennik lub konfigurowalna podstawowa obudowa, gdzie docelowa sonda i opcje zewnętrznego przewodu są wybierane osobno.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZintegrowany czujnik Proximitor:\u003c\/strong\u003e Czujnik 3300 XL Proximitor zamontowany na pokrywie eliminuje potrzebę oddzielnych obudów do kondycjonowania sygnału i kabli przedłużających.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eObudowa z polifenylenosulfidu (PPS):\u003c\/strong\u003e Formowany termoplastik wzmocniony włóknami szklanymi i przewodzącymi zapewnia doskonałe rozpraszanie ładunków elektrostatycznych i ochronę środowiskową.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElastyczna regulacja mechaniczna:\u003c\/strong\u003e Posiada adapter dystansowy o długości 2,0 cala (51 mm) i długość penetracji sondy 3,8 cala (97 mm), aby dopasować się do specyficznej geometrii obudowy maszyny.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandardowy interfejs montażowy:\u003c\/strong\u003e Wyposażony w solidny gwint montażowy 3\/4-14 NPT do sztywnego połączenia z obudową maszyny.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOchrona typu 4X i IP66:\u003c\/strong\u003e Zweryfikowane uszczelnienia obudowy izolują wewnętrzną sondę i elektronikę przed wodą kierowaną wężem oraz silnie korozyjnymi środowiskami.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cp\u003eZintegrowana konfiguracja nadaje się do różnych zastosowań monitorowania ciężkich maszyn obrotowych, w tym:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePomiar drgań promieniowych wału na turbinach parowych, turbinach gazowych i dużych sprężarkach\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie położenia osiowego na pompach wysokoprędkościowych i przemysłowych skrzyniach biegów\u003c\/li\u003e\n  \u003cli\u003eOchrona maszyn przemysłowych, gdzie wymagana jest kompaktowa instalacja przewodów bezpośrednio do monitora\u003c\/li\u003e\n  \u003cli\u003eŚrodowiska korozyjne lub o wysokiej wilgotności, gdzie metalowe obudowy są podatne na degradację\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOpcja \/ segment\u003c\/th\u003e\n      \u003cth\u003eKod tego SKU\u003c\/th\u003e\n      \u003cth\u003eZnaczenie \/ opis\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-00-20-038-00-02\u003c\/td\u003e\n      \u003ctd\u003eZespół przetwornika zbliżeniowego PROXPAC XL (wersja angielska)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Opcja sondy i zatwierdzeń\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eBrak sondy; czujnik Proximitor bez zatwierdzeń\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja adaptera dystansowego B (wymiar B)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003eDługość adaptera dystansowego 2,0 cala (51 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja penetracji sondy C (wymiar C)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e038\u003c\/td\u003e\n      \u003ctd\u003eDługość penetracji sondy 3,8 cala (97 mm) (przyrosty co 0,1 cala)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja złączek D\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eBrak złączek; dwa korki i dwie podkładki\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja gwintu montażowego E\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (wymagane przy zamawianiu opcji adaptera dystansowego)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParametr\u003c\/th\u003e\n      \u003cth\u003eWartość \/ Specyfikacja\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer modelu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-00-20-038-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp systemu przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZintegrowany przetwornik zbliżeniowy PROXPAC XL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKompatybilne wejście sondy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSonda zbliżeniowa 3300 XL 8 mm z kablem o długości 1 metra\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymagania dotyczące zasilania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17,5 V DC do -26 V DC przy maksymalnym prądzie 12 mA (bez barier)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOdpowiedź częstotliwościowa\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 do 10 kHz: +0, -3 dB (z okablowaniem polowym do 305 metrów)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres liniowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2,0 mm (80 mils) z sondą 3300 XL 8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eŚrednica wału docelowego\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMinimalna: 50,8 mm (2,0 cala); Zalecana minimalna: 76,2 mm (3,0 cala)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał obudowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTermoplastyczny poli(tereftalan fenylenu) (PPS) wzmacniany włóknami przewodzącymi, odporny na promieniowanie ultrafioletowe (UV)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał tulei\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZewnętrzna tuleja i śruby mocujące\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 303\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał uszczelki tulei\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeopren\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał wkładki uziemiającej\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał izolacji drgań\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBardzo miękki silikon komórkowy\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKlasa środowiskowa obudowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTyp 4X i IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy sondy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +177°C (-62°F do +351°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy obudowy\/czujnika\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +100°C (-62°F do +212°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +105°C (-62°F do +221°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLimit wilgotności względnej\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% kondensująca, nie do zanurzenia, gdy złącza są chronione\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMoment dokręcania nakrętki zabezpieczającej\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29,5 N·m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMoment dokręcania nakrętki blokującej tulei sondy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e39,3 N·m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cp\u003eDla prawidłowego montażu i długoterminowej niezawodności mechanicznej przestrzegaj następujących zaleceń inżynierskich:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSprawdź, czy łączna suma wymiarów \"B\" i \"C\" nie przekracza 305 mm (12 cali) bez dodatkowego wsparcia tulei sondy w pobliżu końcówki, aby uniknąć rezonansów.\u003c\/li\u003e\n  \u003cli\u003eUpewnij się, że uszczelki O-ring są nasmarowane i prawidłowo osadzone przed montażem, aby utrzymać klasę ochrony IP66.\u003c\/li\u003e\n  \u003cli\u003eZapobiegaj gromadzeniu się wody i rozpuszczalników wewnątrz pokrywy obudowy, prowadząc okablowanie polowe przez rurę spustową nachyloną od obudowy.\u003c\/li\u003e\n  \u003cli\u003eNie wystawiaj końcówki sondy na działanie środowisk o temperaturze poniżej -34°C (-29°F) przed uruchomieniem maszyny, ponieważ niskie temperatury mogą wpłynąć na szczelność ciśnieniową.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eNorma \/ Dyrektywa\u003c\/th\u003e\n      \u003cth\u003eKlasyfikacja zgodności\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZnak CE\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZgodność z dyrektywami Unii Europejskiej\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDyrektywa EMC\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2014\/30\/UE (EN 61000-6-2, EN 61000-6-4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDyrektywa RoHS\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2011\/65\/UE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStopień ochrony przed wnikaniem\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eObudowa z certyfikatem IP66 i NEMA Typ 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529644907,"sku":"330880-00-20-038-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-00-20-038-00-02-proxpac-xl-proximity-transducer-hkz5avir5a4_74ec7400-30cf-4191-a9ec-ca47473077cd.jpg?v=1765440336"},{"product_id":"bently-nevada-3500-42-proximitor®-seismic-monitor-module","title":"Moduł monitorujący sejsmiczny Bently Nevada 3500\/42 Proximitor®","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/42\u003c\/strong\u003e to czterokanałowa karta ochrony maszyn zaprojektowana dla systemu ochrony maszyn \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e, zapewniająca ciągłe monitorowanie drgań i przemieszczeń maszyn. Ten moduł przetwarzania monitorujący na bieżąco przyjmuje sygnały elektryczne z czujników zbliżeniowych, prędkości lub akcelerometrów. \u003cstrong\u003e3500\/42\u003c\/strong\u003e filtruje i skaluje surowe sygnały przetworników do standardowych zmiennych inżynierskich, oceniając parametry zdrowia operacyjnego w czasie rzeczywistym, takie jak drgania promieniowe wału, pozycja osiowego nacisku, ekscentryczność, przyspieszenie, prędkość i rozszerzalność różnicowa.\u003c\/p\u003e\n\u003cp\u003ePracując w ramach szafy 3500, moduł porównuje każdy aktywny kanał pomiarowy z zaprogramowanymi progami alarmowymi i niebezpieczeństwa skonfigurowanymi sprzętowo. Gdy parametry przekraczają normalne wartości, karta natychmiast generuje sygnały alarmowe przez tylną szynę szafy, wywołując automatyczne blokady i polecenia wyłączenia urządzeń, niezależnie od oprogramowania stacji roboczej. Układ urządzenia obejmuje indywidualne konfiguracje par kanałów oraz niezależne pętle wyjścia rejestratora proporcjonalnego do integracji z systemami zarządzania zakładem i zewnętrznymi rejestratorami danych.\u003c\/p\u003e\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCzterokanałowa matryca przetwarzania czujników akceptująca jednoczesne sygnały z czujników zbliżeniowych, prędkości lub przyspieszenia.\u003c\/li\u003e\n\u003cli\u003eKompleksowe programowanie funkcjonalne wspierające drgania promieniowe, pozycję nacisku, ekscentryczność i rozszerzalność różnicową.\u003c\/li\u003e\n\u003cli\u003eKonfigurowalne kanały wejściowe ułożone w pary do wykonywania niezależnego kondycjonowania sygnału i procedur śledzenia.\u003c\/li\u003e\n\u003cli\u003eBuforowane wyjścia przetworników na panelu przednim zapewniające natychmiastowy dostęp koncentryczny dla zewnętrznych dynamicznych analizatorów diagnostycznych.\u003c\/li\u003e\n\u003cli\u003eRedundantne połączenie tylnej szyny 3500 utrzymujące spójne porównania parametrów kanałów i trasowanie blokad bezpieczeństwa.\u003c\/li\u003e\n\u003cli\u003eWyraźne wskaźniki diagnostyczne na przedniej płycie zapewniające natychmiastową widoczność statusu modułu OK, aktywności magistrali TX\/RX oraz trybów obejścia.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCiągłe monitorowanie drgań promieniowych i awarii łożysk olejowych w krytycznych turbosprężarkach zakładu.\u003c\/li\u003e\n\u003cli\u003eBezpośrednie pozycjonowanie osiowego nacisku wału i pętle przemieszczenia wirnika wewnątrz ciężkich turbin parowych do wytwarzania energii.\u003c\/li\u003e\n\u003cli\u003eWysokoprecyzyjne mechaniczne przyspieszenie obudowy i krzyżowe weryfikacje drgań prędkości strukturalnej na dużych modułach silników pomocniczych.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSzczegóły\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOznaczenie modelu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModuł Proximitor \/ monitora sejsmicznego\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZużycie energii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo 7,7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePojemność sygnału wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObsługuje 1 do 4 wejść przetworników zbliżeniowych, prędkości lub przyspieszenia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedancja wejściowa (standardowe I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ (wejścia Proximitor i przyspieszeniowe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDokładność bezpośrednia i szczelinowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypowo w granicach ±0,33% pełnej skali, maksymalnie ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRozdzielczość wyjścia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,3662 µA na bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZgodność napięcia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do +12 Vdc na obciążeniu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres rezystancji obciążenia rejestratora\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do 600 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTłumienie filtra Bias\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-3 dB przy 0,01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTłumienie filtra Not OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-3 dB przy 2400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWydajność częstotliwości odświeżania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms lub mniej\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymiary modułu głównego (W x S x G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMasa netto modułu głównego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury pracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C do +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C do +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOgraniczenia wilgotności\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, bez kondensacji\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePołączenia\/interfejsy\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eElement interfejsu\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrzypisanie funkcji\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrzednie złącza koncentryczne\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCztery dedykowane buforowane porty wyjściowe przetwornika do weryfikacji dynamicznych przebiegów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCiągły zielony wskaźnik pokazujący prawidłowy stan monitora i modułu I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMigający wskaźnik śledzący wymianę komunikatów w czasie rzeczywistym na magistrali szafy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDioda BYPASS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStały wskaźnik sygnalizujący, że parametr kanału lub sekwencja alarmowa jest wyciszona\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTablica wielopinowa tylnej płyty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStałe piny złączy tworzące połączenia zasilania, wejścia i sterowania alarmem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWkładanie do szafy:\u003c\/strong\u003e Wsuń obudowę modułu prosto w przezroczyste prowadnice po prawej stronie modułu interfejsu szafy. Dociśnij mocno, aż zestaw zacisków całkowicie wejdzie do złączy tylnej płyty, następnie zabezpiecz przedni panel śrubami motylkowymi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOkablowanie pola przetwornika:\u003c\/strong\u003e Prowadź sygnały czujnika przez dedykowane, izolowane przewody pomiarowe. Końcówki podłącz do tylnego zespołu zacisków I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUziemienie elektrostatyczne:\u003c\/strong\u003e Podczas rozpakowywania lub modyfikacji zachowuj ciągłe połączenie z zatwierdzonym opaską antystatyczną na nadgarstek, aby chronić wewnętrzne układy analogowe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZarządzanie ciągłością ekranu:\u003c\/strong\u003e Podłącz przewody odprowadzające ekran kabla wejściowego do dedykowanych zacisków ekranu na bloku I\/O, pozostawiając koniec czujnika nieuziemiony, aby wyeliminować standardowe zakłócenia pętli masy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e3500\/42 vs. 3500\/42M: Kluczowe różnice i przewodnik wyboru\u003c\/h3\u003e\n\u003cp\u003ePodczas zarządzania ochroną maszyn legacy, sieciami legacy lub pozyskiwania części zamiennych do systemu \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e, zrozumienie technicznych granic między standardowym monitorem \u003cstrong\u003e3500\/42\u003c\/strong\u003e a ulepszonym monitorem \u003cstrong\u003e3500\/42M\u003c\/strong\u003e (Multimode) Proximitor\/Seismic jest kluczowe dla kompatybilności zakładu.\u003c\/p\u003e\n\u003ch4\u003ePorównanie architektury\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFunkcja \/ Specyfikacja\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMonitor legacy 3500\/42\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eUlepszony monitor 3500\/42M\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneracja sprzętu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWczesna seria produkcyjna bazowa\u003c\/td\u003e\n\u003ctd\u003eNowsza generacja serii Multimode (obecny standard OEM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramowanie kanałów\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFunkcjonalnie ograniczone dla par kanałów za pomocą fizycznych zworek na płycie\u003c\/td\u003e\n\u003ctd\u003eW pełni konfigurowalne programowo dla każdego kanału za pomocą oprogramowania 3500 Rack Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMieszane wejścia czujników\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOgraniczona elastyczność; kanały muszą odpowiadać określonym grupom zworek\u003c\/td\u003e\n\u003ctd\u003eWysoka elastyczność; umożliwia jednoczesne łączenie czujników zbliżeniowych i sejsmicznych na jednej karcie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZaawansowane przetwarzanie sygnału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardowe monitorowanie drgań, położenia osi i prędkości obudowy\u003c\/td\u003e\n\u003ctd\u003eObsługuje zaawansowane algorytmy, w tym REBAM®, Shaft Absolute i Circular Acceptance Region\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKompatybilne tylne karty I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140471-01 (wewnętrzny) \/ 140482-01 (zewnętrzny)\u003c\/td\u003e\n\u003ctd\u003e128229-01 (wewnętrzny) \/ 128240-01 (zewnętrzny)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eZasady wyboru i kompatybilności wstecznej\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBezpośrednia wymiana legacy:\u003c\/strong\u003e Jeśli w Twojej obecnej szafie znajduje się oryginalna główna karta monitorująca \u003cstrong\u003e3500\/42\u003c\/strong\u003e, która uległa degradacji sprzętowej, nowsza \u003cstrong\u003e3500\/42M\u003c\/strong\u003e może pełnić funkcję kompletnego zamiennika. Jest w pełni kompatybilna wstecz z magistralą komunikacyjną tylnej płyty szafy 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eObowiązkowa zasada „Dopasowanej pary”:\u003c\/strong\u003e \u003cstrong\u003eNie można\u003c\/strong\u003e podłączyć przedniej karty monitorującej \u003cstrong\u003e3500\/42M\u003c\/strong\u003e do starszego tylnego modułu I\/O \u003cstrong\u003e3500\/42\u003c\/strong\u003e (i odwrotnie). Wewnętrzne układy ścieżek i elektryczne połączenia pinów są różne. Jeśli zdecydujesz się na modernizację starszego gniazda do serii 42M, musisz zakupić i wymienić \u003cstrong\u003ezarówno przednią kartę monitorującą, jak i tylny moduł I\/O jako dopasowany zestaw\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePonowne wdrożenie konfiguracji:\u003c\/strong\u003e Podczas wymiany starego zestawu sprzętowego 3500\/42 na 3500\/42M technicy terenowi muszą połączyć się za pomocą oprogramowania 3500 Rack Configuration, zmodyfikować typ definicji wyznaczonego gniazda na „3500\/42M”, odwzorować oryginalne metryki przetwornika i wykonać świeże pobranie logiki, aby aktywować gniazdo.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666531938667,"sku":"3500\/42","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42-proximitor-seismic-monitor-0uvaaynfrl1_ba527237-f7d2-4c33-9470-6b25869a7b65.jpg?v=1765440372"},{"product_id":"bently-nevada-330881-br-07-155-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-07-155-06-02 PROXPAC XL Czujnik zbliżeniowy Proximity Transducer","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-BR-07-155-06-02\u003c\/strong\u003e: Ten metryczny \u003cstrong\u003eprzetwornik zbliżeniowy PROXPAC XL\u003c\/strong\u003e wyposażony jest w sondę zbliżeniową 3300 XL 8 mm z aprobatami stref zagrożenia Brazylii INMETRO (Opcja BR), zintegrowany adapter dystansowy 70 mm (Opcja 07) oraz długość tulei penetracji sondy 155 mm (Opcja 155). Konfiguracja dostarczana jest z jednym złączem 3\/4-14 NPT, reduktorem ze stali nierdzewnej 3\/4-14 NPT do 1 1\/2-14 NPT oraz dwoma zaślepkami przewodów (Opcja 06) i wykorzystuje gwint montażowy 3\/4-14 NPT (Opcja 02).\u003c\/p\u003e\n\u003cp\u003eZintegrowana konstrukcja łączy sondę zbliżeniową 3300 XL 8 mm i odpowiadający jej czujnik Proximitor w jednej, samodzielnej obudowie z polifenylenosulfidu (PPS). Takie rozwiązanie eliminuje oddzielny kabel przedłużający i zewnętrzną obudowę Proximitor, umożliwiając bezpośrednie połączenie okablowania z systemem monitoringu do listwy zaciskowej wewnątrz pokrywy przetwornika. Obudowa PPS wzmacniana włóknem szklanym i przewodzącym zapewnia ochronę środowiskową IP66 i typu 4X, zabezpieczając elektronikę wewnętrzną przed surowymi warunkami przemysłowymi, wilgocią i gromadzeniem się ładunków elektrostatycznych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOpcja BR zawiera sondę 3300 XL 8 mm z certyfikatem Brazylii INMETRO dla iskrobezpiecznej i nieiskrzącej ochrony stref zagrożenia.\u003c\/li\u003e\n  \u003cli\u003eOpcja 07 zapewnia długość adaptera dystansowego 70 mm, aby unieść obudowę ponad obudowę maszyny.\u003c\/li\u003e\n  \u003cli\u003eOpcja 155 oznacza długość tulei penetracji sondy 155 mm, dopasowaną do specyfikacji głębokości celu.\u003c\/li\u003e\n  \u003cli\u003eOpcja 06 zawiera wytrzymały złącznik przewodu 3\/4-14 NPT, reduktor ze stali nierdzewnej 1 1\/2-14 NPT oraz podwójne zaślepki.\u003c\/li\u003e\n  \u003cli\u003eOpcja 02 zapewnia gwint montażowy 3\/4-14 NPT dla solidnego połączenia mechanicznego.\u003c\/li\u003e\n  \u003cli\u003eKonstrukcja samodzielna eliminuje zewnętrzne kable przedłużające i zdalne obudowy Proximitor, co zmniejsza błędy okablowania i upraszcza instalację.\u003c\/li\u003e\n  \u003cli\u003ePrzewodząca obudowa z termoplastiku PPS rozprasza ładunki elektrostatyczne oraz jest odporna na promieniowanie ultrafioletowe i agresywne chemikalia.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePomiar drgań wału i położenia osiowego w maszynach wirujących z dużą prędkością.\u003c\/li\u003e\n  \u003cli\u003eMonitorowanie ochrony maszyn, gdzie preferowana jest uproszczona powierzchnia przetwornika i bezpośrednie okablowanie do zacisków w terenie.\u003c\/li\u003e\n  \u003cli\u003eAplikacje o dużym obciążeniu wymagające ochrony obudowy odpornej na korozję IP66 i typu 4X.\u003c\/li\u003e\n  \u003cli\u003eStrefy zagrożenia wymagające certyfikowanej przez INMETRO iskrobezpiecznej lub nieiskrzącej konfiguracji.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOpcja \/ Segment\u003c\/th\u003e\n      \u003cth\u003eKod tego SKU\u003c\/th\u003e\n      \u003cth\u003eOpis \/ Znaczenie\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-BR-07-155-06-02  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZespół przetwornika zbliżeniowego PROXPAC XL (model metryczny)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Opcja sondy i aprobat\u003c\/td\u003e\n      \u003ctd\u003eBR\u003c\/td\u003e\n      \u003ctd\u003eSonda 3300 XL 8 mm z aprobatami Brazylii \/ INMETRO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Opcja adaptera dystansowego\u003c\/td\u003e\n      \u003ctd\u003e07\u003c\/td\u003e\n      \u003ctd\u003eDługość adaptera dystansowego 70 mm (zamawiana w przyrostach co 10 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Opcja penetracji sondy\u003c\/td\u003e\n      \u003ctd\u003e155\u003c\/td\u003e\n      \u003ctd\u003eDługość penetracji tulei sondy 155 mm (zamawiana w przyrostach co 1 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOpcja złączek D\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eJedna złączka 3\/4-14 NPT, jedna redukcja ze stali nierdzewnej 3\/4-14 NPT do 1 1\/2-14 NPT oraz dwie zaślepki  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOpcja gwintu montażowego E  \u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eGwint montażowy 3\/4-14 NPT (wymagany z opcją adaptera dystansowego)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne  \u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ numer części  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-07-155-06-02  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp przetwornika  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZintegrowany przetwornik zbliżeniowy PROXPAC XL  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp sondy  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSonda zbliżeniowa 3300 XL 8 mm  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKabel wejściowy Proximitor  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegralny kabel 1-metrowy podłączony wewnątrz obudowy  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres liniowy  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), zaczynając od 0,25 mm (10 mils) od celu do 2,3 mm (90 mils)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWspółczynnik skali przyrostowej (ISF)  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7,87 V\/mm (200 mV\/mil) +\/-5% w zakresie liniowym (0 do 45°C)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOdchylenie liniowości (DSL)  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOdchylenie liniowości mniejsze niż +\/-0,025 mm (+\/-1 mil) od standardowej linii prostej  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZalecany odstęp  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,27 mm (50 mils)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymagania zasilania  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17,5 Vdc do -26 Vdc (bez barier) przy maks. 12 mA; -23 Vdc do -26 Vdc (z barierami)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRezystancja wyjściowa  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRezystancja DC sondy  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7,59 +\/-0,50 Ohm (nominalna)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał obudowy  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOdporna na promieniowanie UV, polifenylenosulfid (PPS) wzmacniany włóknem szklanym i przewodzącym  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTuleja i łańcuch mocujący  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 304  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eŚruby mocujące i zewnętrzna tuleja  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 303  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał uszczelki tulei O-ring  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeopren  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał izolacji drgań  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBardzo miękki silikon komórkowy  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLimity momentu dokręcania  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNakrętka mocująca: 29,5 N·m (260 in-lb); nakrętka blokująca tulei sondy: 39,3 N·m (350 in-lb)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy sondy  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +177°C (-62°F do +351°F)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKlasa ochrony obudowy  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 i typ 4X  \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePołączenia i interfejsy  \u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterfejs \/ Zaciski  \u003c\/th\u003e\n      \u003cth\u003eSpecyfikacja  \u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePołączenie okablowania polowego  \u003c\/td\u003e\n      \u003ctd\u003eZaciski śrubowe wewnątrz pokrywy obudowy  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePojemność zacisków przewodów  \u003c\/td\u003e\n      \u003ctd\u003eObsługuje przewody o przekroju od 0,2 do 1,5 mm2 (16 do 24 AWG)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eZalecany kabel polowy  \u003c\/td\u003e\n      \u003ctd\u003e3-żyłowy ekranowany kabel trójprzewodowy z cynowanym okablowaniem polowym  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaksymalna odległość do monitora  \u003c\/td\u003e\n      \u003ctd\u003e305 metrów (1000 stóp) między PROXPAC XL a monitorem  \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne  \u003c\/h3\u003e\n\u003cp\u003eMocno zamontuj obudowę za pomocą gwintu 3\/4-14 NPT. Upewnij się, że adapter dystansowy jest prawidłowo wyrównany z portem tulei maszyny. Dokładnie dokręć nakrętkę blokującą tulei sondy momentem 39,3 N·m (350 in-lb) oraz nakrętkę mocującą momentem 29,5 N·m (260 in-lb), aby zapewnić szczelne fizyczne uszczelnienie. Kable polowe muszą być prowadzone przez złączki przewodów dostarczone w opcji 06; dokręć wszystkie złączki i zaślepki, aby utrzymać klasę IP66 i typ 4X obudowy PPS. Upewnij się, że lokalne wytyczne dotyczące uziemienia są przestrzegane, korzystając z zintegrowanego wewnętrznego lineru uziemiającego.  \u003c\/p\u003e\n\n\u003ch3\u003eZgodność i certyfikaty  \u003c\/h3\u003e\n\u003cp\u003eTen zespół przetwornika jest zaprojektowany i certyfikowany zgodnie z następującymi normami przemysłowymi:  \u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eZgodność z oznakowaniem CE  \u003c\/li\u003e\n  \u003cli\u003eKlasa IP66 (potwierdzona raportem BASEEFA T07\/0709)  \u003c\/li\u003e\n  \u003cli\u003eObudowa o stopniu ochrony typu 4X  \u003c\/li\u003e\n  \u003cli\u003eZatwierdzenia INMETRO \/ Brazylia (Opcja BR) dla bezpieczeństwa iskrobezpiecznego (Ex ia) i przeciwwybuchowego (Ex nA\/ec) w atmosferach gazów wybuchowych  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666533347691,"sku":"330881-BR-07-155-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-07-155-06-02-tsi-module-snce4kndaio_ce2e3e91-022f-4c4e-b36a-19552e157cd1.jpg?v=1765440386"},{"product_id":"bently-nevada-330180-x1-cn-mod-143416-05-3300-xl-proximitor-sensor","title":"Czujnik Bently Nevada 330180-X1-CN MOD:143416-05 3300 XL Proximitor","description":"\u003ch3\u003ePrzegląd produktu\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eBently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003e330180-X1-CN MOD:143416-05\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto \u003cmark\u003ewysokoprecyzyjny czujnik prądów wirowych Proximitor należący do systemu przetworników zbliżeniowych \u003cspan\u003e3300 XL\u003c\/span\u003e 8 mm\u003c\/mark\u003e.\u003cspan\u003e \u003c\/span\u003eTen konkretny model obsługuje zarówno pomiary przemieszczeń statycznych (pozycja), jak i dynamicznych (wibracje) na krytycznych elementach maszyn obrotowych. Urządzenie przetwarza odległość między końcówką sondy 8 mm a obserwowaną przewodzącą powierzchnią celu na proporcjonalny analogowy sygnał napięciowy. Konfiguracja \u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e określa układ montażu na szynie DIN 35 mm, natomiast przyrostek \u003cspan class=\"Yjhzub\"\u003eCN\u003c\/span\u003e oznacza lokalne zgodności bezpieczeństwa, w tym zatwierdzenia ATEX\/IECEx oraz chińskie NEPSI dla stref zagrożenia. Oznaczenie konstrukcyjne \u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e reprezentuje fabrycznie skalibrowaną modyfikację zaprojektowaną w celu zwiększenia trwałości elektrycznej i optymalizacji profilu celu w ciężkich warunkach przemysłowych.\u003c\/p\u003e\n\u003ch3\u003eKonfiguracja techniczna\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ctable class=\"NRefec\" width=\"628\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"cZCYO firstRow\"\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eParametr\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eSpecyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eMarka\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003e330180\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eRozszerzenie kodu zamówienia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eX1-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eNumer referencyjny modyfikacji\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eTyp produktu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eCzujnik zbliżeniowy Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eKompatybilność systemu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\nSeria przetworników \u003cspan class=\"Yjhzub\"\u003e3300 XL\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eKonfiguracja elementów montażowych\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eMontaż na standardowej szynie DIN 35 mm (\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eZatwierdzenia do stref zagrożenia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eOznaczenia ATEX, IECEx, NEPSI chińskie (\u003cspan class=\"Yjhzub\"\u003eCN\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eZasada działania czujnika\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003ePętla prądów wirowych\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eZakres odpowiedzi częstotliwościowej\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0 do 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eNominalna integracja średnicy celu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eCzujniki 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eTyp sygnału wyjściowego systemu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eCiągłe analogowe napięcie AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eSzerokość netto produktu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e12,4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eWysokość netto produktu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e12,6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eGłębokość \/ grubość netto produktu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e2,2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eWaga netto produktu\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0,10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eKraj pochodzenia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eStany Zjednoczone (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformacje o zamówieniu\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003ePonieważ komponenty przetworników Bently Nevada posiadają wewnętrzne obwody dopasowujące skalibrowane do dokładnych długości pętli systemu, zamówienie musi określać zarówno konfiguracje podstawowych części, jak i oznaczenia modyfikacji fabrycznych.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nordwel.com\/bently-nevada-330180-x1-cn-mod-143416-05-proximitor-sensor_p16754.html\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eNumer części komponentu:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e330180-X1-CN\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eSufiks modyfikacji fabrycznej:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eKod rodziny systemu:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e3300 XL\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSeria Proximitor\u003c\/span\u003e\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nordwel.com\/bently-nevada-330180-x1-cn-mod-143416-05-proximitor-sensor_p16754.html\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePrzewodnik konfiguracji sprzętu i inżynierii\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch4\u003eWeryfikacja całkowitej długości pętli\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e330180\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCzujnik musi być sparowany z sondą 8 mm oraz kablem przedłużającym o dokładnej całkowitej długości układu elektrycznego (zwykle 5,0 metrów lub 9,0 metrów). Nieodpowiednie dopasowanie modułu proximitor o długości 5 metrów z kablem 9-metrowym przesuwa bazę oscylacji prądów wirowych, powodując poważne błędy współczynnika skali, dryf punktu zerowego oraz niedokładne odczyty drgań maszyny.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eOdporność na zakłócenia RFI i uziemienie obudowy\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eKonstrukcja czujnika \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e3300 XL\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003echarakteryzuje się zaawansowanym ekranowaniem przed zakłóceniami radiowymi (RFI), spełniającym parametry europejskiej normy CE bez konieczności stosowania specjalnych stalowych przewodów ochronnych. Jednak fizyczna szyna montażowa DIN (\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e) musi mieć bezpośrednie, niskooporowe połączenie elektryczne z uziemieniem obudowy przyrządu. Unikaj montażu płytki Proximitor bezpośrednio obok kabli wyjściowych falownika o zmiennej częstotliwości (VFD) o dużej mocy lub bloków styczników.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nexinstrument.com\/330180-x1-cn-mod-143416-34.html\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eOchrona złącza koncentrycznego sondy polowej\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eKable koncentryczne łączące sondę polową z modułem \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e są bardzo wrażliwe na wilgoć, smar i naprężenia mechaniczne. Podczas montażu używaj specjalistycznych silikonowych osłonek na złącza, aby izolować surowe gwinty koncentryczne. Zapewnij ścisłe przestrzeganie minimalnego promienia gięcia kabla przedłużającego wynoszącego 25,4 mm (1,0 cala) w ramach szafki kablowej, aby zapobiec mikropęknięciom w wewnętrznych warstwach ekranu ochronnego.\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eNajczęściej zadawane pytania\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCo oznacza przyrostek MOD:143416-05?\u003c\/strong\u003e\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOznaczenie \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eidentyfikuje modyfikację wykonaną w fabryce, zastosowaną bezpośrednio do wewnętrznych parametrów strojenia serii \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e330180\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e. Często oznacza to zmieniony profil kalibracji, dostosowany do niestandardowych materiałów celów wału, spersonalizowanych wzmocnień sygnału lub specjalistycznych powłok ochronnych na zewnętrznej obudowie.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nordwel.com\/bently-nevada-330180-x1-cn-mod-143416-05-proximitor-sensor_p16754.html\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"wJwe6c\"\u003e\u003cspan class=\"IjM6od\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCzy ten czujnik można wymieniać na gorąco, gdy stojak monitorujący TSI jest włączony?\u003c\/strong\u003e\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTak, czujnik Proximitor można wymienić podczas gdy główny stojak monitorujący (np. stojak Bently Nevada 3500) pozostaje pod napięciem. Jednak odłączenie czujnika natychmiast przerwie obwód pętli, powodując przejście odpowiedniego kanału stojaka w stan „Niestabilny\/Błąd”. Przed wymianą sprzętu należy obejść lub zablokować wszelkie automatyczne przekaźniki wyłączające, aby uniknąć przypadkowego zatrzymania maszyny.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCo oznaczają tagi X1 i CN w konfiguracji zamówienia?\u003c\/strong\u003e\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eKonfiguracja \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ezapewnia, że obudowa czujnika Proximitor jest wyposażona w zintegrowaną stopę konstrukcyjną zaprojektowaną do standardowego montażu na szynie DIN. Oznaczenie \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eCN\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ewskazuje, że produkt spełnia określone regionalne wymagania dla Chin, posiadając znaki NEPSI dotyczące stref zagrożenia wybuchem oraz dane ATEX\/IECEx.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666533445995,"sku":"330180-X1-CN MOD:143416-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-cn-mod-143416-05-proximity-interface-module-ir4xttrnbna_19ca2830-6c66-4cb4-aed3-2151e21bb306.jpg?v=1765440387"},{"product_id":"bently-nevada-330881-28-07-155-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-07-155-06-02 PROXPAC XL Przetwornik zbliżeniowy","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-07-155-06-02\u003c\/strong\u003e: Ta metryczna konfiguracja \u003cstrong\u003eprzetwornika zbliżeniowego PROXPAC XL\u003c\/strong\u003e zawiera sondę 3300 XL 8 mm z wieloma aprobatami (Opcja 28), adapter dystansowy 70 mm (Opcja 07), głębokość penetracji sondy 155 mm (Opcja 155), specjalistyczny zestaw złączek (Opcja 06) oraz gwint montażowy 3\/4-14 NPT (Opcja 02).\u003c\/p\u003e\n\u003cp\u003eW przeciwieństwie do konfiguracji niezatwierdzonych lub wariantów bez adaptera dystansowego, ten zespół integruje solidny, certyfikowany łańcuch monitorujący w trwałej obudowie z polifenylenosiarczku (PPS). PROXPAC XL łączy sondę i czujnik Proximitor w jeden zintegrowany system, redukując wymagania dotyczące okablowania zewnętrznego poprzez bezpośrednie połączenie z monitorami Bently Nevada.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOpcja 28 integruje sondę 3300 XL 8 mm z certyfikatem wielu aprobat do stref zagrożonych wybuchem.\u003c\/li\u003e\n\u003cli\u003eOpcja 07 określa adapter dystansowy metryczny 70 mm, aby ustawić zespół z dala od przeszkód.\u003c\/li\u003e\n\u003cli\u003eOpcja 155 zapewnia długość penetracji sondy 155 mm do obudowy maszyny.\u003c\/li\u003e\n\u003cli\u003eOpcja 06 dostarcza zestaw złączek zawierający jedną złączkę 3\/4-14 NPT, reduktor ze stali nierdzewnej 3\/4-14 NPT do 1 1\/2-14 NPT oraz dwie zaślepki.\u003c\/li\u003e\n\u003cli\u003eOpcja 02 ustanawia gwint montażowy 3\/4-14 NPT dla zewnętrznej tulei.\u003c\/li\u003e\n\u003cli\u003eObudowa wykonana z termoplastu polifenylenosiarczku (PPS) wzmacnianego włóknem szklanym i przewodzącym zapewnia ochronę IP66 oraz rozpraszanie ładunków elektrostatycznych.\u003c\/li\u003e\n\u003cli\u003eKonstrukcja z bezpośrednim połączeniem integruje czujnik Proximitor bezpośrednio w pokrywie obudowy, eliminując potrzebę stosowania kabla przedłużającego.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cp\u003eTypowe zastosowania obejmują pomiar drgań wału i położenia osiowego w przemysłowych maszynach obrotowych, turbinach parowych i gazowych, sprężarkach odśrodkowych oraz dużych pompach, gdzie wymagana jest redukcja okablowania zewnętrznego i skrzynek przyłączeniowych.\u003c\/p\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOpcja \/ Parametr\u003c\/th\u003e\n\u003cth\u003eKod tego SKU\u003c\/th\u003e\n\u003cth\u003eOpis \/ Specyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer części do zamówienia\u003c\/td\u003e\n\u003ctd\u003e330881-28-07-155-06-02\u003c\/td\u003e\n\u003ctd\u003ePrzetwornik zbliżeniowy PROXPAC XL, metryczny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpcja A - Sonda i aprobaty\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003eSonda 3300 XL 8 mm z wieloma aprobatami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpcja B - Adapter dystansowy\u003c\/td\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003eDługość dystansu 70 mm (Opcja B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpcja C - Penetracja sondy\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003ctd\u003eDługość penetracji 155 mm (Opcja C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpcja D - Złączki\u003c\/td\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eJedno złącze 3\/4-14 NPT, jeden reduktor SST 3\/4-14 NPT do 1 1\/2-14 NPT oraz dwa korki\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpcja gwintu montażowego E\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (wymagane przy zamawianiu opcji adaptera dystansowego)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumer części\/model\u003c\/td\u003e\n\u003ctd\u003e330881-28-07-155-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWejście czujnika proximitor\u003c\/td\u003e\n\u003ctd\u003eSonda zbliżeniowa 3300 XL 8 mm z kablem o długości 1 metra zainstalowana w tulei sondy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWymagania zasilania\u003c\/td\u003e\n\u003ctd\u003eWymaga -17,5 Vdc do -26 Vdc bez barier przy maksymalnym prądzie 12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres liniowy\u003c\/td\u003e\n\u003ctd\u003eZakres liniowy 2,0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZalecana szczelina\u003c\/td\u003e\n\u003ctd\u003eZalecana szczelina 1,27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWyjście systemu\u003c\/td\u003e\n\u003ctd\u003e7,87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePasmo przenoszenia\u003c\/td\u003e\n\u003ctd\u003e0 do 10 kHz: +0, -3 dB przy okablowaniu do 305 metrów (1000 stóp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimalny rozmiar celu\u003c\/td\u003e\n\u003ctd\u003eŚrednica 15,2 mm (0,6 cala) (płaski cel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eŚrednica wału (minimalna)\u003c\/td\u003e\n\u003ctd\u003eŚrednica wału 50,8 mm (2,0 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał końcówki sondy\u003c\/td\u003e\n\u003ctd\u003ePolifenylenosulfid (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał obudowy sondy\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKabel sondy\u003c\/td\u003e\n\u003ctd\u003eKabel sondy o długości 1 metra, trójosiowy 75 omów, izolowany fluoroetylenopropylenem (FEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZłącze sondy\u003c\/td\u003e\n\u003ctd\u003eZłocone mosiężne złącze ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał obudowy\u003c\/td\u003e\n\u003ctd\u003eTermoplastik polifenylenosulfidowy (PPS) wzmacniany włóknem szklanym, odporny na promieniowanie UV, zawierający włókna przewodzące\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał tulei i łańcuch mocujący\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZewnętrzna tuleja i śruby mocujące\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał uszczelki O-ring tulei\u003c\/td\u003e\n\u003ctd\u003eNeopren\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePodkładka uziemiająca i płyta mocująca\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał izolacji drgań\u003c\/td\u003e\n\u003ctd\u003eBardzo miękki silikon komórkowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał etykiety pokrywy\u003c\/td\u003e\n\u003ctd\u003eBłyszczący biały poliester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKlasa szczelności obudowy\u003c\/td\u003e\n\u003ctd\u003ePotwierdzona klasa szczelności IP66 \/ Typ 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura pracy sondy\u003c\/td\u003e\n\u003ctd\u003e-52°C do +177°C (-62°F do +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura pracy obudowy sondy i proximitor\u003c\/td\u003e\n\u003ctd\u003e-52°C do +100°C (-62°F do +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWilgotność względna\u003c\/td\u003e\n\u003ctd\u003e100% kondensujący, nie do zanurzenia, gdy złącza są chronione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cp\u003eZainstaluj zewnętrzny zespół tulei w obudowie maszyny, używając uszczelniacza na gwincie montażowym (3\/4-14 NPT). Wyreguluj szczelinę sondy w obudowie za pomocą nakrętki blokującej tulei sondy (moment dokręcania 39,3 N·m \/ 350 in-lb). Przykręć nakrętki mocujące pokrywę do momentu 29,5 N·m (260 in-lb). Zachowaj standardowe środki ostrożności przemysłowej, aby zapobiec przedostawaniu się wilgoci z zewnątrz bezpośrednio do obudowy przez przewód.\u003c\/p\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cp\u003eZgodność z CE. Obudowa o klasie szczelności BASEEFA IP66. Opcja pakietu wielu zatwierdzeń zawiera certyfikaty dla stref zagrożonych wybuchem (CSA, ATEX, IECEx tam, gdzie ma to zastosowanie).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666537509227,"sku":"330881-28-07-155-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-07-155-06-02-proxpac-xl-proximity-transducer-qnj0v05fasj_5753b3e4-fffd-4751-8d80-6c86cae606ef.jpg?v=1765440430"},{"product_id":"bently-nevada-330881-br-04-70-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-70-03-02 PROXPAC XL Czujnik zbliżeniowy Proximity Transducer","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-BR-04-70-03-02\u003c\/strong\u003e określa metryczną konfigurację przetwornika zbliżeniowego Bently Nevada PROXPAC XL, integrującą sondę 8 mm z wieloma zatwierdzeniami do stref zagrożonych (Opcja BR) w samodzielnym zespole ochronnym. Ta zintegrowana konstrukcja łączy sondę 3300 XL 8 mm i czujnik Proximitor 3300 XL w jednej obudowie z polifenylenosulfidu (PPS) montowanej na maszynie. Takie rozwiązanie eliminuje potrzebę stosowania zewnętrznych kabli przedłużających i osobnych obudów Proximitorów, umożliwiając bezpośrednie prowadzenie okablowania z obudowy do systemu monitoringu.\u003c\/p\u003e\n\n\u003cp\u003eDla precyzyjnej regulacji mechanicznej i wyrównania, ta wersja posiada adapter dystansowy 40 mm (Opcja 04) oraz długość penetracji sondy 70 mm (Opcja 70). Integralność środowiskowa jest zapewniona przez obudowę z PPS wzmocnioną włóknem szklanym i przewodzącym, która skutecznie rozprasza ładunki elektrostatyczne i spełnia normy IP66 oraz NEMA Typ 4X. Ta konkretna konfiguracja metryczna jest dostarczana z jednym złączem M20 i dwoma zaślepkami (Opcja 03) do wejścia przewodu elektrycznego oraz wykorzystuje gwint 3\/4-14 NPT (Opcja 02) do bezpiecznego montażu na obudowie maszyny.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZintegrowany projekt zespołu\u003c\/strong\u003e: Łączy sondę 3300 XL 8 mm i czujnik Proximitor w jednej obudowie, eliminując konieczność stosowania osobnych kabli przedłużających i dedykowanych zdalnych obudów nadajnika.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiele zatwierdzeń do stref zagrożonych wybuchem\u003c\/strong\u003e: Opcja BR (oznaczenie odpowiadające Opcji 28 w dokumentacji metrycznej Bently Nevada) certyfikuje zespół do klasyfikacji ATEX, IECEx i CSA dla stref zagrożonych wybuchem.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegulowana głębokość\u003c\/strong\u003e: Zawiera tuleję penetracyjną sondy o długości 70 mm (Opcja 70) oraz adapter dystansowy 40 mm (Opcja 04) do precyzyjnego ustawienia końcówki czujnika.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eObudowa z odpornego na korozję PPS\u003c\/strong\u003e: Formowany termoplastik wzmocniony włóknem szklanym i przewodzącym zapewnia solidną odporność chemiczną, na promieniowanie UV i uderzenia oraz rozpraszanie ładunków elektrostatycznych.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStopień ochrony IP66 i Typ 4X\u003c\/strong\u003e: Zaprojektowany do bezpośredniego montażu na maszynie w trudnych warunkach przemysłowych, zapewniając wysoką ochronę przed wilgocią, kurzem i myciem.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBezpieczne wejścia przewodów\u003c\/strong\u003e: Zawiera jedno złącze M20 i dwie zaślepki (Opcja 03) zapobiegające przedostawaniu się zanieczyszczeń do portów wejściowych kabli.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cp\u003eSystem służy do ciągłych, bezkontaktowych pomiarów drgań wału i położenia osiowego w maszynach wirujących. Typowe zastosowania obejmują:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTurbiny parowe i gazowe w elektrowniach.\u003c\/li\u003e\n  \u003cli\u003eSprężarki odśrodkowe i pompy w zakładach naftowych, gazowych i petrochemicznych.\u003c\/li\u003e\n  \u003cli\u003eDuże wentylatory przemysłowe, dmuchawy i przekładnie.\u003c\/li\u003e\n  \u003cli\u003eMiejsca o dużych obciążeniach lub ograniczonej przestrzeni, gdzie zdalne obudowy Proximitorów nie mogą być łatwo zainstalowane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment opcji\u003c\/th\u003e\n      \u003cth\u003eKod na tym SKU\u003c\/th\u003e\n      \u003cth\u003eZnaczenie z PDF\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel bazowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003eZespół przetwornika zbliżeniowego PROXPAC XL (metryczny)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja sondy i certyfikatów A\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBR\u003c\/td\u003e\n      \u003ctd\u003eSonda 3300 XL 8 mm z wieloma certyfikatami (równoważna kodowi opcji 28)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja adaptera dystansowego B\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003eDługość adaptera dystansowego 40 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja penetracji sondy C\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e70\u003c\/td\u003e\n      \u003ctd\u003eDługość tulei penetracyjnej sondy 70 mm (070)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja złączy D\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eJedno złącze M20, dwie zaślepki\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja gwintu montażowego E\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eGwint montażowy 3\/4-14 NPT (wymagany z adapterem dystansowym)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części \/ model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-70-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZintegrowany przetwornik zbliżeniowy\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp sondy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSonda zbliżeniowa 3300 XL 8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres liniowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2,0 mm (80 mils), zaczynając od około 0,25 mm (10 mils) od celu\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWspółczynnik skali przyrostowej (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7,87 V\/mm (200 mV\/mil) nominalnie\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres napięcia wejściowego\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17,5 Vdc do -26 Vdc (bez barier) przy maksymalnym prądzie 12 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpór wyjściowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 omów\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOgraniczenia zacisków przewodów polowych\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0,2 do 1,5 mm2 (16 do 24 AWG); zalecany ekranowany trójprzewodowy trójżyłowy kabel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaksymalna długość przewodów polowych\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 metrów (1000 stóp) między czujnikiem Proximitor a systemem monitoringu\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał obudowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOdporna na promieniowanie ultrafioletowe (UV), wzmacniana włóknem szklanym politereftalan fenylenu (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał zewnętrznej tulei \/ adaptera\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 303 i AISI 304\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał uszczelki tulei\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeopren\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMoment dokręcania nakrętki zabezpieczającej\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29,5 N·m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMoment dokręcania nakrętki blokującej\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e39,3 N·m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy (sonda)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +177°C (-62°F do +351°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy (obudowa)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +100°C (-62°F do +212°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStopień ochrony\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 i NEMA Typ 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUziemienie w terenie\u003c\/strong\u003e: Wewnętrzna wkładka uziemiająca i płyta mocująca muszą być prawidłowo połączone. Ekran przewodów polowych uziemiaj wyłącznie na końcu monitora, aby wyeliminować potencjalne zakłócenia pętli uziemienia.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegralność gwintu\u003c\/strong\u003e: Użyj gwintu montażowego 3\/4-14 NPT do połączenia z obudową maszyny. Zastosuj standardowy moment obrotowy 39,3 N·m (350 in-lb) na nakrętce blokującej oraz 29,5 N·m (260 in-lb) na nakrętce zabezpieczającej.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrzerwa kalibracyjna\u003c\/strong\u003e: Ustaw zalecaną odległość przerwy na 1,27 mm (50 mils), aby ustalić nominalne napięcie polaryzacji środkowej -10 Vdc w oknie pomiarowym o długości 2 mm.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWejścia przewodów\u003c\/strong\u003e: Solidnie wkręć dostarczony element M20. Zablokuj wszystkie nieużywane porty wejściowe za pomocą dostarczonych zaślepek, aby zachować szczelność środowiskową IP66 i NEMA Typ 4X.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOznakowanie CE\u003c\/strong\u003e: Tak\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStopień ochrony\u003c\/strong\u003e: IP66 (potwierdzone przez BASEEFA) oraz NEMA Typ 4X\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertyfikaty do stref zagrożenia wybuchem (Opcja BR)\u003c\/strong\u003e: Certyfikaty ATEX, IECEx i CSA dla klasy I dywizji 1 (grupy A, B, C, D) oraz aplikacji Ex ia IIC T4\/T5 Ga bezpiecznych iskrobezpiecznych, gdy zainstalowane zgodnie z rysunkiem Bently Nevada 141092.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666540786027,"sku":"330881-BR-04-70-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-70-03-02-proxpac-xl-proximity-transducer-koeckaklyin_2a7b3143-0755-4a7b-bbdf-c06ccee219f1.jpg?v=1765440463"},{"product_id":"bently-nevada-330880-28-15-035-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals) and Option 15 (1.5 in standoff adapter) specify this \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e configuration — \u003cstrong\u003e330880-28-15-035-00-02\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis integrated proximity transducer assembly combines the probe and Proximitor sensor into a single polyphenylene sulfide (PPS) housing. The self-contained design eliminates the need for an external extension cable between the probe and Proximitor sensor, as well as the need for a separate Proximitor junction enclosure. Field wiring connects directly between the monitors and the internal terminals. This configuration features a 3.5 in probe penetration depth (Option 035), no conduit fittings (Option 00), and a 3\/4-14 NPT mounting thread (Option 02) suitable for severe industrial machinery case interfaces.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTransducer probe with multiple hazardous area approvals (ATEX, IECEx, and CSA) for explosion-proof and intrinsically safe installations.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Proximitor sensor in the housing lid to eliminate external extension cables.\u003c\/li\u003e\n  \u003cli\u003eConductive glass-fiber-reinforced polyphenylene sulfide (PPS) thermoplastic housing rated IP66 and Type 4X.\u003c\/li\u003e\n  \u003cli\u003e1.5 in (38 mm) standoff adapter with a 3\/4-14 NPT thread for rigid casing mounting.\u003c\/li\u003e\n  \u003cli\u003e3.5 in (89 mm) stainless steel probe sleeve length for direct case penetration.\u003c\/li\u003e\n  \u003cli\u003eSupplied with two plugs and two washers under the no-fittings option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurements on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eDirect integration on turbines, compressors, pumps, and industrial gearboxes.\u003c\/li\u003e\n  \u003cli\u003eEnvironments requiring IP66 or Type 4X protection against chemical exposure, moisture, and dust.\u003c\/li\u003e\n  \u003cli\u003eHazardous industrial environments requiring intrinsically safe or non-incendive field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n      \u003ctd\u003e330880-28-15-035-00-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, English\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n      \u003ctd\u003e1.5 in (38 mm) standoff length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n      \u003ctd\u003e035\u003c\/td\u003e\n      \u003ctd\u003e3.5 in (89 mm) penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330880-28-15-035-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Component\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Proximity Transducer Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), from 0.25 mm to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Requirement\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB) with up to 305 m (1000 ft) of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShaft Diameter Limits\u003c\/td\u003e\n      \u003ctd\u003eMinimum 50.8 mm (2.0 in), Recommended 76.2 mm (3.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eUV-resistant, glass-reinforced conductive polyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case and Sleeve Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature (Probe)\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature (Housing\/Sensor)\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X when properly sealed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTorque the housing retaining nut to 29.5 N-m (260 in-lb).\u003c\/li\u003e\n  \u003cli\u003eTorque the probe sleeve locknut to 39.3 N-m (350 in-lb) to maintain the environmental pressure seal.\u003c\/li\u003e\n  \u003cli\u003eVerify that the internal grounding liner and retaining plate are clean and securely fastened.\u003c\/li\u003e\n  \u003cli\u003eEnsure field wiring terminals are protected by an enclosure of at least IP54.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum separation of 40 mm (1.6 in) for axial installations or 38 mm (1.5 in) for radial configurations to avoid cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eATEX\/IECEx\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc (Intrinsically Safe); Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc (Non-sparking)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNorth American (cNRTLus)\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III (Intrinsically Safe)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNon-Incendive\u003c\/td\u003e\n      \u003ctd\u003eClass I, Division 2, Groups A, B, C, D; Class I, Zone 2: AEx\/Ex nA IIC T4\/T5 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCE Mark\u003c\/td\u003e\n      \u003ctd\u003eComplies with European directives\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666541277547,"sku":"330880-28-15-035-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-28-15-035-00-02-proxpac-xl-proximity-transducer-assembly-crqcbgmfy4r_5e47900b-f87c-4c72-b762-dc57faaefd73.jpg?v=1765440470"},{"product_id":"bently-nevada-330880-28-35-017-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-28-35-017-00-02 PROXPAC XL Czujnik zbliżeniowy Proximity Transducer","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330880-28-35-017-00-02\u003c\/strong\u003e: Zestaw przetwornika zbliżeniowego PROXPAC XL w jednostkach angielskich skonfigurowany z sondą zbliżeniową 3300 XL 8 mm z wieloma aprobatami (Opcja 28), adapterem dystansowym o długości 3,5 cala (89 mm) (Opcja 35), głębokością penetracji sondy 1,7 cala (43 mm) (Opcja 017), bez osprzętu przewodów (Opcja 00) oraz tuleją gwintowaną montażową 3\/4-14 NPT (Opcja 02).\u003c\/p\u003e\n\u003cp\u003eTen zintegrowany projekt mieści sondę zbliżeniową 3300 XL 8 mm oraz dopasowany czujnik Proximitor bezpośrednio w obudowie sondy z termoplastu polifenylenosulfidowego (PPS) wzmacnianego włóknem szklanym. Łącząc oba elementy w jednej obudowie o klasie szczelności Typ 4X i IP66, ta konfiguracja eliminuje konieczność stosowania zewnętrznego kabla przedłużającego i oddzielnej obudowy czujnika Proximitor. Okablowanie polowe łączy się bezpośrednio z listwą zaciskową wewnątrz obudowy z systemem monitoringu, upraszczając montaż fizyczny i instalację elektryczną w trudnych warunkach przemysłowych. Zintegrowana sonda 3300 XL 8 mm działa na standardowych zasadach prądów wirowych do pomiaru drgań wału i położenia osiowego w maszynach obrotowych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZintegrowany zestaw mieści zarówno sondę zbliżeniową 3300 XL 8 mm, jak i dopasowany czujnik Proximitor w jednej obudowie.\u003c\/li\u003e\n\u003cli\u003eOpcja 28 określa sondę 3300 XL 8 mm wyposażoną w wiele aprobat (takich jak CSA, ATEX i IECEx) do instalacji w strefach zagrożonych wybuchem.\u003c\/li\u003e\n\u003cli\u003eOpcja 35 zapewnia adapter dystansowy o długości 3,5 cala (89 mm) do odsunięcia obudowy od obudowy maszyny.\u003c\/li\u003e\n\u003cli\u003eOpcja 017 ustawia długość penetracji sondy na 1,7 cala (43 mm) w obudowie maszyny.\u003c\/li\u003e\n\u003cli\u003eOpcja 00 oznacza, że zestaw dostarczany jest bez dodatkowych osprzętów przewodów, w tym dwóch zaślepek i dwóch podkładek.\u003c\/li\u003e\n\u003cli\u003eOpcja 02 wykorzystuje tuleję gwintowaną montażową 3\/4-14 NPT do połączenia mechanicznego.\u003c\/li\u003e\n\u003cli\u003eObudowa wykonana z formowanego termoplastu polifenylenosulfidowego (PPS) wzmacnianego włóknem szklanym, odpornego na promieniowanie UV, zawierającego przewodzące włókna do rozpraszania ładunków elektrostatycznych.\u003c\/li\u003e\n\u003cli\u003eKlasa szczelności Typ 4X i IP66 zapewnia ochronę przed wilgocią i kurzem w trudnych warunkach.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePomiary drgań promieniowych wału i położenia osiowego wału w obracających się maszynach przemysłowych.\u003c\/li\u003e\n\u003cli\u003eSurowe środowiska przemysłowe, takie jak rafinerie ropy naftowej i gazu, zakłady petrochemiczne oraz elektrownie.\u003c\/li\u003e\n\u003cli\u003eModernizacja obudów maszyn, gdzie nie można zamontować oddzielnej skrzynki połączeniowej Proximitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSegment opcji\u003c\/th\u003e\n\u003cth\u003eKod opcji\u003c\/th\u003e\n\u003cth\u003eSzczegóły konfiguracji\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330880-28-35-017-00-02\u003c\/td\u003e\n\u003ctd\u003ePrzetwornik zbliżeniowy PROXPAC XL, jednostki angielskie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Opcja sondy i aprobat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003eSonda 3300 XL 8 mm z wieloma aprobatami\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Opcja adaptera dystansowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003eDługość adaptera dystansowego 3,5 cala (89 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Opcja penetracji sondy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e017\u003c\/td\u003e\n\u003ctd\u003eGłębokość penetracji sondy 1,7 cala (43 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Opcja osprzętu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak złączek (dostarczone z dwoma zaślepkami i dwoma podkładkami)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Opcja gwintu montażowego\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (wymagane do adaptera dystansowego)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330880-28-35-017-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp produktu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrzetwornik zbliżeniowy PROXPAC XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTyp sondy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSonda zbliżeniowa 3300 XL 8 mm (zainstalowana w tulei)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWymagania zasilania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWymaga -17,5 Vdc do -26 Vdc przy maksymalnym prądzie 12 mA (bez barier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOdpowiedź częstotliwościowa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 do 10 kHz: +0, -3 dB (z przewodem do 305 m \/ 1000 stóp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres liniowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,0 mm (80 mils), zaczynając od około 0,25 mm (10 mils) od celu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWspółczynnik skali systemu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalny rozmiar celu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15,2 mm (0,6 cala) średnicy (płaski cel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimalna średnica wału\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50,8 mm (2,0 cala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał obudowy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTermoplastyczny poli(tereftalan fenylenu) (PPS) wzmacniany włóknami szklanymi, odporny na UV, z włóknami przewodzącymi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał tulei\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZewnętrzna tuleja i śruby\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStal nierdzewna AISI 303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał uszczelki O-ring tulei\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeopren\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał izolacji drgań\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBardzo mięki silikon komórkowy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriał etykiety pokrywy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBłyszczący biały poliester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStopień ochrony przed wnikaniem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eObudowa klasy 4X \/ IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWytrzymałość obudowy na uderzenia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertyfikat BASEEFA na 4 dżule przy -39°C i 115°C; weryfikacja CSA na 7 dżuli w temperaturze otoczenia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury sondy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C do +177°C (-62°F do +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura pracy obudowy\/czujnika\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C do +100°C (-62°F do +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZakres temperatury przechowywania\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C do +105°C (-62°F do +221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit wilgotności względnej\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% kondensujący, nie do zanurzenia, gdy złącza są chronione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cp\u003eUpewnij się, że zewnętrzna tuleja jest prawidłowo zamontowana do obudowy maszyny za pomocą opcji gwintu montażowego 3\/4-14 NPT (Opcja 02), aby zapewnić bezpieczne i izolowane od drgań połączenie. Należy stosować standardowe momenty dokręcania: nakrętka mocująca musi być dokręcona momentem 29,5 N·m (260 in-lb), a nakrętka blokująca tulei sondy momentem 39,3 N·m (350 in-lb). Elementy lineru uziemiającego i płyty mocującej muszą być prawidłowo osadzone, aby zapobiec gromadzeniu się ładunków elektrostatycznych. Wszystkie przewody powinny być odpowiednio uszczelnione, aby zapobiec przedostawaniu się wilgoci i kondensacji z zewnątrz przez przewód do obudowy przetwornika.\u003c\/p\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cp\u003eTen system przetwornika jest certyfikowany zgodnie z oznaczeniem CE Unii Europejskiej, Dyrektywą EMC 2014\/30\/EU (normy EN 61000-6-2 i EN 61000-6-4) oraz Dyrektywą RoHS 2011\/65\/EU. Zatwierdzenia do stref zagrożonych regulują normy CSA\/NRTL\/US oraz ATEX\/IECEx. System jest certyfikowany do klasy I, strefy 0: AEx\/Ex ia IIC T4\/T5 Ga oraz klasy I, podziału 2, grup A, B, C, D, gdy jest zainstalowany z odpowiednimi barierami bezpieczeństwa wewnętrznego lub izolatorami galwanicznymi zgodnie z rysunkami kontrolnymi. Obudowa jest niezależnie oceniona pod kątem spełnienia kryteriów ochrony przed wnikaniem typu 4X i IP66.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666542817643,"sku":"330880-28-35-017-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-28-35-017-00-02-proximity-transducer-jzk2zjqqkcn_0eb5d17b-f451-4b11-b43e-058c21064e54.jpg?v=1765440487"},{"product_id":"bently-nevada-330881-br-04-110-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-110-06-02 PROXPAC XL Czujnik zbliżeniowy Proximity Transducer","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003eOpcja BR (sonda 3300 XL 8 mm z zatwierdzeniami INMETRO) oraz opcja 04 (adapter dystansowy 40 mm) określają konfigurację tego metrycznego zintegrowanego zespołu przetwornika zbliżeniowego — \u003cstrong\u003e330881-BR-04-110-06-02 PROXPAC XL przetwornik zbliżeniowy\u003c\/strong\u003e. Konstrukcja samodzielna integruje czujnik Proximitor 3300 XL bezpośrednio w pokrywie obudowy, eliminując potrzebę osobnych kabli przedłużających i zewnętrznych skrzynek przyłączeniowych Proximitor. Okablowanie polowe łączy się bezpośrednio wewnątrz obszaru zacisków, upraszczając układ i zmniejszając całkowitą złożoność okablowania systemu.\u003c\/p\u003e\n\u003cp\u003eFormowana obudowa termoplastyczna z polifenylenosulfidu (PPS) jest wzmocniona szkłem i włóknami przewodzącymi, zapewniając wytrzymałość mechaniczną i rozpraszanie ładunków elektrostatycznych w strefach zagrożenia. Konfiguracja ta posiada tuleję penetracyjną sondy o długości 110 mm, złączki przewodów NPT oraz gwint montażowy 3\/4-14 NPT. Działa w oparciu o technologię bezkontaktową prądów wirowych do pomiaru dynamicznych drgań wału i położenia osiowego w maszynach obrotowych przemysłowych.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFormowana obudowa termoplastyczna z polifenylenosulfidu (PPS) przeznaczona do środowisk typu 4X i IP66 o wysokiej odporności.\u003c\/li\u003e\n  \u003cli\u003eSzkło i włókna przewodzące włączone w materiał PPS do bezpiecznego rozpraszania ładunków elektrostatycznych.\u003c\/li\u003e\n  \u003cli\u003eKonstrukcja samodzielna z czujnikiem Proximitor zintegrowanym w pokrywie obudowy, eliminująca zewnętrzne okablowanie sondy do czujnika.\u003c\/li\u003e\n  \u003cli\u003eMechanizm regulacji tulei gwintowanej umożliwiający ruch osiowy do plus lub minus 12,7 mm dla precyzyjnego ustawienia szczeliny.\u003c\/li\u003e\n  \u003cli\u003eWewnętrzna izolacja drgań wykorzystująca bardzo miękki silikon komórkowy do ochrony wewnętrznych komponentów przed drganiami strukturalnymi.\u003c\/li\u003e\n  \u003cli\u003eZaciski do okablowania polowego zaprojektowane do przyjmowania cynowanych przewodów o przekroju od 0,2 do 1,5 mm2 (16 do 24 AWG).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDynamiczny monitoring drgań promieniowych wału w krytycznych maszynach obrotowych.\u003c\/li\u003e\n  \u003cli\u003ePomiary położenia osiowego wału i przemieszczenia osiowego w maszynach użyteczności publicznej i przemysłowych.\u003c\/li\u003e\n  \u003cli\u003eZastosowania wymagające zatwierdzeń stref zagrożenia INMETRO (Brazylia) dla bezpiecznej eksploatacji.\u003c\/li\u003e\n  \u003cli\u003eŚrodowiska przetwarzania korozyjnego lub o wysokiej wilgotności, gdzie wymagane jest uszczelnienie środowiskowe typu 4X i IP66.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment opcji\u003c\/th\u003e\n      \u003cth\u003eWybrany kod\u003c\/th\u003e\n      \u003cth\u003eZnaczenie opcji\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel bazowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003eZespół przetwornika zbliżeniowego PROXPAC XL, metryczny\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja sondy i zatwierdzeń A\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBR\u003c\/td\u003e\n      \u003ctd\u003eSonda 3300 XL 8 mm z zatwierdzeniami INMETRO (Brazylia) dla stref zagrożenia wybuchem\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja adaptera odstępu B\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003eDługość adaptera odstępu 40 mm (wymiar B)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja penetracji sondy C\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e110\u003c\/td\u003e\n      \u003ctd\u003eDługość tulei penetracji sondy 110 mm (wymiar C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja złączy D\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eJedno złącze 3\/4-14 NPT, jedno przejście ze stali nierdzewnej 3\/4-14 NPT na 1 1\/2-14 NPT oraz dwa korki\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOpcja gwintu montażowego E\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eGwint montażowy 3\/4-14 NPT (wymagany z adapterem odstępu)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProducent\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumer części\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-110-06-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeria produktu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSeria PROXPAC XL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTyp przetwornika\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZintegrowany zespół przetwornika zbliżeniowego (metryczny)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZakres liniowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), zaczynając od około 0,25 mm (10 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWspółczynnik skali przyrostowej (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7,87 V\/mm (200 mV\/mil) nominalnie\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWymagania zasilania\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17,5 V DC do -26 V DC przy maksymalnym prądzie 12 mA (bez barier)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eImpedancja wyjściowa\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 omów\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eZalecana szczelina\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał obudowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOdporne na UV, wzmacniane włóknem szklanym polifenylenosiarczek (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał tulei i obudowy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStal nierdzewna AISI 304\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMateriał uszczelki tulei\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeopren\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIzolacja drgań\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBardzo miękki silikon komórkowy\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUszczelnienie środowiskowe\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTyp 4X i IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy (obudowa i czujnik)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +100°C (-62°F do +212°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperatura pracy (tylko sonda)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52°C do +177°C (-62°F do +351°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimalny rozmiar celu\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePłaski cel o średnicy 15,2 mm (0,6 cala)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimalna średnica wału\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50,8 mm (2,0 cala)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cp\u003eZintegrowany przetwornik jest montowany za pomocą gwintów 3\/4-14 NPT. Tuleja osiowa zapewnia do plus lub minus 12,7 mm regulacji gwintowanej, aby dokładnie wyregulować szczelinę sondy przed ostatecznym zablokowaniem. Dla długości penetracji („B” odstęp plus „C” penetracja) przekraczających 305 mm, należy zainstalować dodatkowe wsparcie tulei w pobliżu końcówki sondy, aby zminimalizować rezonans i odkształcenia. Zakończ okablowanie polowe wewnątrz pokrywy obudowy, używając cynowanych przewodów o przekroju od 0,2 do 1,5 mm2 (16 do 24 AWG).\u003c\/p\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eZatwierdzenia INMETRO (Brazylia) dla stref zagrożenia wybuchem dotyczące bezpieczeństwa wewnętrznego i instalacji nieiskrzących.\u003c\/li\u003e\n  \u003cli\u003eZgodność z oznaczeniem CE.\u003c\/li\u003e\n  \u003cli\u003eZgodność z dyrektywą RoHS 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003eKlasyfikacje ochrony środowiskowej IP66 i Typ 4X.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666544357739,"sku":"330881-BR-04-110-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-110-06-02-proxpac-xl-housing-pwfrsps2bhp_6b9c29bc-5b2b-43cc-8c5f-e637ab6eaa35.jpg?v=1765440502"},{"product_id":"bently-nevada-330850-91-00-3300-xl-25-mm-proximitor-sensor","title":"Czujnik Bently Nevada 330850-91-00 3300 XL Proximitor 25 mm","description":"\u003ch3\u003eOpis\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330850-91-00\u003c\/strong\u003e określa \u003cstrong\u003e3300 XL 25 mm Proximitor Sensor\u003c\/strong\u003e skonfigurowany z długością systemu 9,0 m i montażem na szynie DIN, przeznaczony do instalacji nie wymagających certyfikatów stref zagrożenia wybuchem.\u003c\/p\u003e\n\u003cp\u003eTen czujnik stanowi integralną część systemu przetwornika zbliżeniowego 3300 XL 25 mm, zaprojektowanego do bezkontaktowych pomiarów przemieszczeń prądem wirowym na dużych celach, szczególnie do monitorowania różnicowej dylatacji (DE) i rozszerzania obudowy turbiny parowej. Przetwarzając wysokoczęstotliwościowy sygnał RF z sondy zbliżeniowej 330851 i kabla przedłużającego 330854, czujnik Proximitor dostarcza skalowany analogowy sygnał wyjściowy o wartości 0,787 V\/mm (20 mV\/mil). W porównaniu do wersji montowanych na panelu lub alternatywnych konfiguracji 5,0 m, ta wersja z montażem na szynie DIN o długości 9,0 m oferuje wydłużony zasięg systemu oraz wygodny standardowy montaż na szynie DIN wewnątrz lokalnych obudów przyrządów.\u003c\/p\u003e\n\n\u003ch3\u003eCechy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOpcja 91 określa długość systemu 9,0 m z zintegrowanym osprzętem montażowym na szynę DIN.\u003c\/li\u003e\n\u003cli\u003eOpcja 00 zapewnia standardową konfigurację bez zatwierdzeń agencji ds. stref zagrożenia wybuchem.\u003c\/li\u003e\n\u003cli\u003eZgodny z sondami zbliżeniowymi i kablami przedłużającymi serii Bently Nevada 3300 XL 25 mm.\u003c\/li\u003e\n\u003cli\u003eDostarcza nominalny średni współczynnik skali 0,787 V\/mm (20 mV\/mil) w zakresie liniowym 12,7 mm (500 mils).\u003c\/li\u003e\n\u003cli\u003eAkceptuje zasilanie w zakresie od -17,5 Vdc do -26 Vdc.\u003c\/li\u003e\n\u003cli\u003eUtrzymuje stałą rezystancję wyjściową 50 omów.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eZastosowania\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitorowanie różnicowej dylatacji turbiny parowej (DE)\u003c\/li\u003e\n\u003cli\u003ePomiary rozszerzania obudowy wirnika\u003c\/li\u003e\n\u003cli\u003eZastosowania pomiarów przemieszczeń prądem wirowym na dużych celach\u003c\/li\u003e\n\u003cli\u003eMonitorowanie pozycji osiowej turbiny parowej\u003c\/li\u003e\n\u003cli\u003eOchrona ciężkich maszyn wirujących w przemyśle\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInformacje o zamówieniu\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOpcja\u003c\/th\u003e\n\u003cth\u003eKod na tym SKU\u003c\/th\u003e\n\u003cth\u003eOpis\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumer części do zamówienia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330850-91-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpcja AA - Całkowita długość i montaż\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003ctd\u003eDługość systemu 9,0 m (29,5 stopy), montaż na szynie DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpcja BB - Zatwierdzenie agencji\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBrak zatwierdzeń\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecyfikacje techniczne\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametr\u003c\/th\u003e\n\u003cth\u003eSpecyfikacja\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducent\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Numer części\u003c\/td\u003e\n\u003ctd\u003e330850-91-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZgodność systemu\u003c\/td\u003e\n\u003ctd\u003eSystem przetwornika zbliżeniowego 3300 XL 25 mm (sondy 330851, kable 330854)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZasilanie wejściowe\u003c\/td\u003e\n\u003ctd\u003eWymaga -17,5 Vdc do -26 Vdc (bez barier) przy maksymalnym poborze 12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres liniowy\u003c\/td\u003e\n\u003ctd\u003e12,7 mm (500 mils), zaczynając od około 0,63 mm (25 mils) od celu (od 0,63 do 13,33 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres napięcia wyjściowego\u003c\/td\u003e\n\u003ctd\u003eOkoło -1,5 Vdc do -11,5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eŚredni współczynnik skali (ASF)\u003c\/td\u003e\n\u003ctd\u003e0,787 V\/mm (20 mV\/mil) nominalnie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOdchylenie od najlepszej linii dopasowania (DSL)\u003c\/td\u003e\n\u003ctd\u003eMniej niż +\/-0,31 mm (+\/-12 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePasmo przenoszenia\u003c\/td\u003e\n\u003ctd\u003e0 do 2,7 kHz (+0, -3 dB typowo przy okablowaniu do 305 metrów)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZalecany minimalny rozmiar celu\u003c\/td\u003e\n\u003ctd\u003e61 mm (2,4 cala) średnicy (płaski cel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRezystancja wyjściowa\u003c\/td\u003e\n\u003ctd\u003e50 omów\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriał czujnika Proximitor\u003c\/td\u003e\n\u003ctd\u003eAluminium A380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres temperatur pracy\u003c\/td\u003e\n\u003ctd\u003e-51 stopni Celsjusza do +100 stopni Celsjusza (-60 do +212 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZakres temperatur przechowywania\u003c\/td\u003e\n\u003ctd\u003e-51 stopni Celsjusza do +105 stopni Celsjusza (-60 do +221 stopni Fahrenheita)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWilgotność względna\u003c\/td\u003e\n\u003ctd\u003e100% kondensująca, nie do zanurzenia przy zabezpieczonych złączach (testowane zgodnie z IEC 68-2-3 wilgotność i ciepło)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDługość systemu\u003c\/td\u003e\n\u003ctd\u003e9,0 m (łączna długość sondy i kabla przedłużającego)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTyp montażu\u003c\/td\u003e\n\u003ctd\u003eMontaż na szynie DIN 35 mm (Opcja 91)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZatwierdzenia\u003c\/td\u003e\n\u003ctd\u003eBrak (Opcja 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaga\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz) (tylko czujnik)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWytyczne instalacyjne\u003c\/h3\u003e\n\u003cp\u003eDla optymalnej instalacji czujnika Proximitor 330850 z montażem na szynie DIN, upewnij się, że jest on solidnie zamocowany na standardowej szynie DIN 35 mm. Zamocuj zaciski okablowania polowego (0,2 do 1,5 mm2 lub 16 do 24 AWG) używając ekranowanego kabla triadowego o maksymalnej długości 305 metrów (1000 stóp) do systemu monitorującego. Utrzymuj złącza koncentryczne między kablem przedłużającym a sondą dokręcone ręcznie lub dokręć momentem do maksymalnie 0,565 N-m (5 in-lb). Proximitor musi być umieszczony w czystej, suchej obudowie zapewniającej co najmniej ochronę IP54, aby zapobiec narażeniu na wilgoć i zanieczyszczenia.\u003c\/p\u003e\n\n\u003ch3\u003eZgodność i certyfikaty\u003c\/h3\u003e\n\u003cp\u003eTo urządzenie spełnia wymagania europejskiej normy CE.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666545471851,"sku":"330850-91-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330850-91-00-3300-xl-25-mm-proximitor-sensor-kqn4tpazt2e_52780fc8-0130-4fce-befe-d29ffb0c362a.jpg?v=1765440516"},{"product_id":"bently-nevada-330880-28-20-038-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-28-20-038-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals) and Option 20 (2.0 in standoff adapter) specify the exact mechanical and electrical layout of this \u003cstrong\u003e330880-28-20-038-00-02\u003c\/strong\u003e integrated \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly. This design integrates a 3300 XL 8 mm proximity probe and its matching 1-metre Proximitor sensor directly into a single, robust housing cover. By consolidating these components, the assembly eliminates the need for separate extension cables and dedicated Proximitor housings. The field wiring connects directly inside the terminal compartment of the transducer housing, significantly simplifying system design, decreasing connector-related signal losses, and reducing overall installation costs.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration is built with an Option 038 probe penetration length of 3.8 inches (97 mm) and is supplied under Option 00 (no conduit fittings; includes two sleeve plugs and two washers). It utilizes Option 02, providing a 3\/4-14 NPT outer sleeve mounting thread to secure the unit to the machinery casing. The housing itself is molded from a high-durability, UV-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic embedded with conductive fibers to dissipate static charges. Sibling configurations within this family vary by offering metric mounting threads, different standoff adapter lengths, or pre-packaged conduit fittings, making this specific English-threaded, 3.8-inch penetration unit the ideal configuration for standardized medium-depth machine cases.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 Probe Integration: Features a pre-installed 3300 XL 8 mm proximity probe with Multiple Approvals (CSA, ATEX, IECEx) for hazardous area conditions.\u003c\/li\u003e\n  \u003cli\u003eOption 20 Standoff Length: Includes a 2.0 in (51 mm) standoff adapter to adjust probe positioning relative to the target shaft.\u003c\/li\u003e\n  \u003cli\u003eOption 038 Sleeve Penetration: Outfitted with a 3.8 in (97 mm) probe sleeve length suitable for medium-depth machine case penetration.\u003c\/li\u003e\n  \u003cli\u003eOption 00 Fittings Package: Shipped without external conduit fittings, containing instead two plastic plugs and two washers for standard sealing.\u003c\/li\u003e\n  \u003cli\u003eOption 02 Mounting Thread: Utilizes a standard 3\/4-14 NPT outer sleeve thread to secure the standoff adapter.\u003c\/li\u003e\n  \u003cli\u003eGlass-Reinforced PPS Housing: Constructed from advanced molded thermoplastic containing conductive fibers to strengthen the outer shell and prevent electrostatic hazards.\u003c\/li\u003e\n  \u003cli\u003eSelf-Contained Design: Minimizes cable management overhead by housing both probe and sensor elements in a single IP66 and Type 4X rated enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position monitoring on high-speed rotating shafts in steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n  \u003cli\u003eSimplified field installations where separate Proximitor enclosures are impractical due to physical layout constraints.\u003c\/li\u003e\n  \u003cli\u003eCorrosive or highly humid industrial environments, including petrochemical refineries, power plants, and gas processing facilities.\u003c\/li\u003e\n  \u003cli\u003eDirect integration with Bently Nevada 3500 and 3300 machinery protection monitors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, English threads and sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 in (51 mm) standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e038\u003c\/td\u003e\n      \u003ctd\u003e3.8 in (97 mm) probe sleeve penetration length (C dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; two plugs and two washers included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required for Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-28-20-038-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIntegrated Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-metre cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIntegrated Sensor Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting at approximately 0.25 mm (10 mils) up to 2.3 mm (90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Output Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately -1 Vdc to -17 Vdc over the linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% over 0 to +45 degC (+32 to +113 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/- 0.025 mm (+\/- 1 mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres (1000 feet) of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating: -52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Chain Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Adjustment:\u003c\/strong\u003e The threaded sleeve design allows for a mechanical adjustment of +\/- 12.7 mm (+\/- 0.5 in) from the nominal insertion point. Ensure the probe is gapped to the standard 1.27 mm (50 mils) before securing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRequired Torque:\u003c\/strong\u003e Tighten the housing retaining nut to 29.5 N-m (260 in-lb) and the outer probe sleeve locknut to 39.3 N-m (350 in-lb) to maintain a secure process seal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Sealing:\u003c\/strong\u003e Users must seal all conduit entries to prevent moisture from traveling through the field conduit into the main terminal compartment. Tighten the lid screws properly to maintain Type 4X and IP66 protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrostatic Grounding:\u003c\/strong\u003e Ensure the internal metallic grounding liner and plate are properly integrated into the system ground loop to effectively dissipate electrostatic charges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American (CSA):\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Division 2, Groups A, B, C, and D.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc; Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with European Community Directive EMC 2014\/30\/EU and RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e Rated for Type 4X and IP66 environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666553991531,"sku":"330880-28-20-038-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-28-20-038-00-02-proximity-transducer-mc0hs1izr4b_e388e5d1-c09c-4896-b486-bd6a52e7027c.jpg?v=1765440603"},{"product_id":"bently-nevada-330881-br-04-150-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-150-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies an integrated 3300 XL 8 mm proximity probe with INMETRO (Brazil) hazardous area approvals in this metric configuration of the \u003cstrong\u003eBently Nevada 330881-BR-04-150-06-02\u003c\/strong\u003e \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e. It combines a proximity probe and a Proximitor sensor into a single self-contained housing, removing the requirement for an external extension cable between the probe and Proximitor sensor, as well as the need for a separate Proximitor junction enclosure. The direct field-wiring connection streamlines installation on rotating machinery and reduces overall loop complexity.\u003c\/p\u003e\n\u003cp\u003eThe housing is constructed from glass-reinforced polyphenylene sulfide (PPS), a tough thermoplastic engineered to dissipate electrostatic charges and resist corrosive environmental exposure. Rated for Type 4X and IP66, this assembly ensures ingress protection in severe industrial environments. This specific configuration includes a 40 mm standoff adapter and a 150 mm probe penetration sleeve with a 3\/4-14 NPT mounting thread and a robust NPT fittings kit for conduit routing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated design embeds a 3300 XL Proximitor sensor directly into the housing lid to eliminate extension cables and junction boxes.\u003c\/li\u003e\n\u003cli\u003eOption BR provides INMETRO approvals for safe deployment in Brazilian hazardous areas.\u003c\/li\u003e\n\u003cli\u003ePPS thermoplastic housing is reinforced with glass and conductive fibers for electrostatic dissipation and mechanical strength.\u003c\/li\u003e\n\u003cli\u003eEnvironmental protection rated at Type 4X and IP66 for demanding plant locations.\u003c\/li\u003e\n\u003cli\u003eSleeve and standoff design allows convenient external adjustment and access to the proximity probe without dismantling the machine casing.\u003c\/li\u003e\n\u003cli\u003eDouble NPT conduit entry fittings with stainless steel reducers for robust mechanical conduit connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eCommon industrial installations include shaft vibration and axial position measurements on rotating machinery such as steam turbines, gas turbines, centrifugal compressors, gearboxes, pumps, and fans. The unified construction is especially effective in locations where traditional proximity system installation space is limited or where minimizing external cabling is desired to improve mechanical protection.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-150-06-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBR\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazil) hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e40 mm Standoff Adapter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e150 mm probe penetration length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-150-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe, 1-metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Linear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% under nominal conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (no barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 m of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing and Sensor Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (subject to hazardous area limitations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eGlass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve and Retaining Chain\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sleeve \u0026amp; Screws\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Liner\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Isolation\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eType 4X, IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe transducer assembly must be mounted on a flat surface using the 3\/4-14 NPT mounting thread (Option 02) which handles the physical engagement of the 40 mm standoff adapter. To avoid cross-talk, ensure the probe tips maintain a separation distance of at least 40 mm for axial position measurements and 38 mm for radial vibration measurements. Connect the field wiring using a 3-conductor twisted shielded cable with a drain wire (typically 1.0 mm2 or 18 AWG) between the internal terminal board and the associated monitor system. Shield grounding must be terminated at the monitor end, ensuring the shield remains isolated at the housing to prevent ground loops.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe unit complies with the European CE mark requirements, EMC Directive 2014\/30\/EU, and RoHS Directive 2011\/65\/EU. Additionally, the housing IP66 rating is verified by BASEEFA, and the Option BR configuration satisfies INMETRO hazardous area standards for intrinsic safety and non-incendive installations in Brazil.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666554646891,"sku":"330881-BR-04-150-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-150-06-02-proxpac-xl-housing-0b0adnjt2mb_23bbe603-9766-41d2-87ef-9a3e4035ae18.jpg?v=1765440614"},{"product_id":"bently-nevada-330881-br-04-145-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-145-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies a 3300 XL 8 mm proximity probe with INMETRO (Brazil) hazardous area approvals integrated inside this metric \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly — \u003cstrong\u003e330881-BR-04-145-06-02\u003c\/strong\u003e. This configuration combines a non-contact eddy-current probe and a 3300 XL Proximitor sensor directly within a single glass-reinforced polyphenylene sulfide (PPS) housing. This integrated design removes the need for an external extension cable and separate Proximitor housing, allowing field wiring to connect directly from the monitor to the transducer assembly. This metric configuration is built with a 40 mm standoff adapter (Option 04) and a 145 mm probe penetration sleeve (Option 145), coupled with specific SST reducers and fittings (Option 06) and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eThe PPS housing material replaces traditional metals, incorporating glass and conductive fibers to strengthen the assembly and dissipate electrostatic charges. Rated for Type 4X and IP66 environments, the housing protects the internal electrical components in severe environments. The internal probe consists of a 1-meter triaxial cable constructed with fluoroethylene propylene (FEP) insulation, terminating in a gold-plated ClickLoc connector. Integrating both probe and sensor together reduces installation steps and cabling costs on critical rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption BR provides an integrated 3300 XL 8 mm proximity probe with INMETRO (Brazil) hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 04 specifies a 40 mm standoff adapter length (B Dimension).\u003c\/li\u003e\n  \u003cli\u003eOption 145 specifies a 145 mm probe penetration length (C Dimension) in the sleeve assembly.\u003c\/li\u003e\n  \u003cli\u003eOption 06 includes a fittings kit consisting of one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two plugs.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides a 3\/4-14 NPT mounting thread (required for standoff adapter configurations).\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) thermoplastic housing is glass and conductive fiber-reinforced to dissipate electrostatic charges.\u003c\/li\u003e\n  \u003cli\u003eType 4X and IP66 environmental ratings provide protection against hose-directed water and environmental ingress.\u003c\/li\u003e\n  \u003cli\u003eTriaxial FEP-insulated 1-meter probe cable with a gold-plated ClickLoc connector connects probe to the integrated Proximitor sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed in industrial rotating machinery such as gas turbines, steam turbines, centrifugal compressors, pumps, and fans where external probe adjustment is required but space or wiring runs do not permit separate Proximitor housings.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eOption Code\u003c\/th\u003e\n    \u003cth\u003eThis SKU Value\u003c\/th\u003e\n    \u003cth\u003eDescription\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n    \u003ctd\u003e330881-BR-04-145-06-02\u003c\/td\u003e\n    \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n    \u003ctd\u003eBR\u003c\/td\u003e\n    \u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazil) approvals\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n    \u003ctd\u003e04\u003c\/td\u003e\n    \u003ctd\u003e40 mm standoff adapter length (B Dimension)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n    \u003ctd\u003e145\u003c\/td\u003e\n    \u003ctd\u003e145 mm probe penetration length (C Dimension)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n    \u003ctd\u003e06\u003c\/td\u003e\n    \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n    \u003ctd\u003e02\u003c\/td\u003e\n    \u003ctd\u003e3\/4-14 NPT (required if ordering Standoff Adapter Option)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eParameter\u003c\/th\u003e\n    \u003cth\u003eValue\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eManufacturer\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n    \u003ctd\u003e330881-BR-04-145-06-02\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTransducer Type\u003c\/td\u003e\n    \u003ctd\u003ePROXPAC XL Proximity Transducer (Metric)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProximitor Sensor Input\u003c\/td\u003e\n    \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-meter cable length\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePower Requirements\u003c\/td\u003e\n    \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eLinear Range\u003c\/td\u003e\n    \u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNominal Scale Factor\u003c\/td\u003e\n    \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eFrequency Response\u003c\/td\u003e\n    \u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n    \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n    \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n    \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n    \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Cable\u003c\/td\u003e\n    \u003ctd\u003e1-meter length, 75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Connector\u003c\/td\u003e\n    \u003ctd\u003eGold-plated brass ClickLoc connector\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHousing Material\u003c\/td\u003e\n    \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOuter Sleeve Material\u003c\/td\u003e\n    \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRetaining Screws Material\u003c\/td\u003e\n    \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSleeve O-ring Material\u003c\/td\u003e\n    \u003ctd\u003eNeoprene\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eGrounding Liner \/ Retaining Plate\u003c\/td\u003e\n    \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eVibration Isolation Material\u003c\/td\u003e\n    \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eLid Label Material\u003c\/td\u003e\n    \u003ctd\u003eGloss Radiant White Polyester\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRetaining Nut Torque\u003c\/td\u003e\n    \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Sleeve Locknut Torque\u003c\/td\u003e\n    \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHousing Impact Strength\u003c\/td\u003e\n    \u003ctd\u003eCertified by BASEEFA to withstand two separate 4 Joule (5.4 ft-lb) impacts at -39 degC and at 115 degC; CSA verified to withstand 7 Joule (9.5 ft-lb) at room temperature\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Operating Temperature Range\u003c\/td\u003e\n    \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Housing \u0026amp; Proximitor Sensor Operating Temp\u003c\/td\u003e\n    \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n    \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHumidity Ingress Rating\u003c\/td\u003e\n    \u003ctd\u003e100% condensing, non-submersible (when connectors are protected); Housing is rated Type 4X and IP66\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eTerminal\u003c\/th\u003e\n    \u003cth\u003eFunction\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCOM\u003c\/td\u003e\n    \u003ctd\u003eCommon \/ Ground\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOUT\u003c\/td\u003e\n    \u003ctd\u003eSignal Output\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eVT\u003c\/td\u003e\n    \u003ctd\u003ePower Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThe PROXPAC XL design seals differential pressure between the probe tip and the housing main body when used with a 3300 XL 8 mm probe.\u003c\/li\u003e\n  \u003cli\u003eEnsure sleeve assemblies with combined standoff and penetration dimensions greater than 305 mm (12.0 in) receive additional sleeve support near the probe tip to stiffen the assembly against resonance.\u003c\/li\u003e\n  \u003cli\u003eAdjust the threaded sleeve within the +\/-12.7 mm (0.5 in) allowable margin to establish the appropriate probe gap.\u003c\/li\u003e\n  \u003cli\u003eImplement correct grounding and shielding practices to prevent electrical interference from impacting signal quality.\u003c\/li\u003e\n  \u003cli\u003ePrevent ingress of external fluids and moisture by routing conduits with appropriate drip loops and sealing field entries properly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark (EMC Directive 2014\/30\/EU; RoHS Directive 2011\/65\/EU)\u003c\/li\u003e\n  \u003cli\u003eCSA\/NRTL\/C Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx Ex II 1 G Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc\u003c\/li\u003e\n  \u003cli\u003eINMETRO Approvals (Brazil) - Option BR\u003c\/li\u003e\n  \u003cli\u003eABS Marine Type Approval (2019 Rules for Conditions of Classification)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666556612971,"sku":"330881-BR-04-145-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-145-06-02-housing-3uawjlii5jb_288fa69f-f671-45cb-a6aa-b9e47112a60e.jpg?v=1765440620"},{"product_id":"bently-nevada-330881-br-04-85-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-85-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies INMETRO (Brazil) Multiple Approvals with an integrated 3300 XL 8 mm probe, while Option 04 and Option 85 provide a 40 mm standoff adapter and 85 mm probe penetration for this metric assembly — the \u003cstrong\u003e330881-BR-04-85-03-02\u003c\/strong\u003e \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis integrated design brings together the proximity probe, sleeve, and 3300 XL Proximitor sensor into a single, self-contained polymer housing. By eliminating the typical extension cable between probe and sensor, the assembly reduces field wiring complexity and simplifies installation on rotating machinery. The housing cover is molded from glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers, providing Type 4X and IP66 protection against harsh chemical and moisture environments. Field wiring runs directly from the integrated terminal connections to monitoring systems, removing the need for a separate Proximitor sensor enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption BR provides INMETRO (Brazil) hazardous area approvals for zone-rated environments.\u003c\/li\u003e\n\u003cli\u003eOption 04 includes a 40 mm metric stainless steel standoff adapter to match specific casing clearances.\u003c\/li\u003e\n\u003cli\u003eOption 85 defines a probe penetration sleeve length of 85 mm.\u003c\/li\u003e\n\u003cli\u003eOption 03 supplies a metric installation fitting kit with one M20 conduit fitting and two plugs.\u003c\/li\u003e\n\u003cli\u003eOption 02 utilizes a standard 3\/4-14 NPT mounting thread for rigid mechanical attachment.\u003c\/li\u003e\n\u003cli\u003eSelf-contained design combines a 3300 XL 8 mm probe and a 1-meter Proximitor sensor in one housing.\u003c\/li\u003e\n\u003cli\u003eGlass-reinforced polyphenylene sulfide (PPS) housing resists chemical degradation and dissipates electrostatic charges.\u003c\/li\u003e\n\u003cli\u003eDirect terminal-to-monitor field wiring eliminates intermediate extension cables and separate driver enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft vibration and axial position monitoring on large industrial rotating assets.\u003c\/li\u003e\n\u003cli\u003eContinuous machinery protection in oil and gas, petrochemical, and power generation environments.\u003c\/li\u003e\n\u003cli\u003eEnvironments requiring strict compliance with Brazilian INMETRO hazardous area standards.\u003c\/li\u003e\n\u003cli\u003eWet, corrosive, or high-moisture installations where Type 4X and IP66 environmental protection is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-85-03-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBR\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with INMETRO Multiple Approvals (Brazil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e40 mm Standoff Adapter Option (B Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Probe Penetration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e85 mm Probe Penetration Option (C Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Fittings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Mounting Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-85-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe (with 1-meter cable length installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-meter length, 75 Ohm triaxial, fluoroethylene propylene (FEP) insulated with gold-plated brass ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils) over 0.25 mm to 2.30 mm range (-1 Vdc to -17 Vdc nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal (plus\/minus 5% interchangeability error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than plus\/minus 0.025 mm (plus\/minus 1 mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 meters \/ 1000 feet of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in) for cross-talk under 50 mV; 76.2 mm (3.0 in) recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 4X, IP66 rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Threads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Penetration Sleeve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve \u0026amp; Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Designation\u003c\/th\u003e\n\u003cth\u003eSignal Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-VT\u003c\/td\u003e\n\u003ctd\u003ePower Supply Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon Ground Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eVibration\/Position Output Signal (nominal 7.87 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure correct mechanical alignment of the outer sleeve assembly during insertion. The standoff adapter must be properly threaded and torqued to avoid loose mechanical coupling. Maintain a recommended gap setting of 1.27 mm (50 mils) between the probe tip and target shaft surface. Use 3-conductor shielded twisted-pair field wiring of 0.2 to 1.5 mm2 (16 to 24 AWG) to connect directly to the integrated Proximitor terminal block inside the housing cover. Route the wiring through M20 fittings while sealing any unused conduit entrances using the supplied blanking plugs to maintain the IP66 and Type 4X rating.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe integrated transducer is certified with INMETRO hazardous area approvals for zone-rated environments in Brazil. The outer housing holds an IP66 rating verified by BASEEFA and complies with the European CE mark requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666562838891,"sku":"330881-BR-04-85-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-85-03-02-housing-2lwukvzad1a_22e806b9-fd90-4c57-8279-2eb87e29d5ab.jpg?v=1765440687"},{"product_id":"bently-nevada-330880-16-15-020-02-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-16-15-020-02-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 16 (non-approved 8 mm probe), Option 15 (1.5-inch standoff adapter), and Option 020 (2.0-inch penetration) specify the 3300 XL configuration of this PROXPAC XL Proximity Transducer — \u003cstrong\u003e330880-16-15-020-02-02\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis design combines the 3300 XL 8 mm proximity probe and its associated Proximitor sensor inside a single, unified PPS housing assembly. By combining these components, it eliminates the need for an external extension cable between the probe and Proximitor, as well as the separate housing typically required. Standard field wiring connects directly from the monitor to the PROXPAC housing, simplifying installation in tight or harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated assembly contains a 3300 XL 8 mm proximity probe and its companion 1-metre Proximitor sensor directly in the housing lid.\u003c\/li\u003e\n\u003cli\u003eEquipped with a 1.5 in (38 mm) standoff adapter to adjust mounting depth and clear machine obstructions.\u003c\/li\u003e\n\u003cli\u003eProvides a 2.0 in (51 mm) probe penetration option through the machine casing.\u003c\/li\u003e\n\u003cli\u003eIncludes a fittings kit with two 3\/4-14 NPT conduit fittings and one blanking plug.\u003c\/li\u003e\n\u003cli\u003eUtilizes a robust 3\/4-14 NPT outer sleeve mounting thread to secure the assembly to the machine case.\u003c\/li\u003e\n\u003cli\u003eMolded polyphenylene sulfide (PPS) housing resists ultraviolet exposure and incorporates glass and conductive fibers to dissipate static charges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis integrated transducer assembly is ideal for machinery protection systems where space is constrained and a separate Proximitor housing cannot be accommodated. Common applications include shaft vibration and axial position monitoring on steam turbines, gas turbines, centrifugal compressors, and heavy industrial pumps.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption \/ Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330880-16-15-020-02-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer (English version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Probe and Approvals\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe without approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Standoff Adapter Length\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1.5 in (38 mm) standoff adapter (B dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Probe Penetration Length\u003c\/td\u003e\n\u003ctd\u003e020\u003c\/td\u003e\n\u003ctd\u003e2.0 in (51 mm) probe penetration (C dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eTwo 3\/4-14 NPT fittings, one plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (required if ordering Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330880-16-15-020-02-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres \/ 1000 feet of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-metre length, 75 Ohm triaxial, FEP insulated with ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve and Retaining Chain Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Pressure Seal Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +177 degC (-62 to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +100 degC (-62 to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e76.2 mm (3.0 in) minimum (50.8 mm \/ 2.0 in absolute minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure proper electrical insulation and mechanical alignment, mount the assembly securely to the machine case using the 3\/4-14 NPT outer sleeve thread. Ground the housing liner using the internal ground plate. When running conduit, prevent water or moisture accumulation by utilizing the supplied 3\/4-14 NPT fittings kit and sealing the conduit entry paths appropriately.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL proximity transducer assembly meets the following mechanical and electrical standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCE marked (European Union electromagnetic compatibility directives)\u003c\/li\u003e\n\u003cli\u003eIP66 rating verified by BASEEFA\u003c\/li\u003e\n\u003cli\u003eType 4X enclosure rating\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666564870507,"sku":"330880-16-15-020-02-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-16-15-020-02-02-proxpac-xl-proximity-transducer-nw1lvcr4hnm_0ca0013a-291a-477b-93fd-7f6a4658ba8f.jpg?v=1765440719"},{"product_id":"bently-nevada-330180-x1-cn-mod-145004-82-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-CN MOD 145004-82 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN MOD 145004-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a highly specialized 3300 XL Proximitor Sensor engineered for precise machinery protection in the most demanding industrial environments. This specific configuration is tailored for the Chinese market, meeting stringent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEPSI\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCC\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSRRC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eregulatory requirements for hazardous area operation and electromagnetic compatibility. Unlike standard proximity sensors calibrated for 4140 steel, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD 145004-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant is factory-calibrated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNi-Cr-Mo-V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Nickel-Chrome-Moly-Vanadium) target materials. This specialized calibration is critical for assets like high-pressure steam turbines or specialized compressors where exotic alloy shafts are utilized. By providing a linearized 7.87 V\/mm (200 mV\/mil) output against non-standard metallurgy, this sensor ensures the integrity of vibration and position data, preventing false trips or missed alerts in mission-critical rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Modification Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe technical complexity of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its specific ordering options and hardware modifications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX1 Modification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates a custom hardware configuration featuring DIN rail mounting for high-density cabinet installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN (China Specific Options):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNEPSI certified for explosive atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCCC mandatory safety certification and SRRC radio frequency approval.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChina RoHS compliant with a 50-year environment-friendly use period (EFUP).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD 145004-82:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates a factory modification to the Printed Wiring Assembly (PWA) and calibration process. This \"MOD\" replaces the standard 4140 steel working standard with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNi-Cr-Mo-V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etarget (Target CT # CT-0069), ensuring the 3300 XL system maintains its linear range across the specialized material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-X1-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModification Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMOD 145004-82\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNi-Cr-Mo-V (Nickel-Chrome-Molybdenum-Vanadium)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 metre (Standard 3300 XL 5mm\/8mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 to 2.3 mm (10 to 90 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Scale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Zero\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-3.0 VDC @ 20 mils\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEPSI, CCC, SRRC, China RoHS (50 years)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 VDC to -26 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the MOD 145004-82 required instead of a standard 330180?\u003c\/strong\u003eProximity sensors operate on eddy current principles, which are highly sensitive to target metallurgy. A standard sensor calibrated for 4140 steel will produce significant scale factor errors when measuring a Ni-Cr-Mo-V shaft. The MOD 145004-82 hardware is physically adjusted and calibrated to this specific alloy to ensure accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat system length must be used with this Proximitor?\u003c\/strong\u003ePer the labeling information, this unit is designed for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0 metre\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. You must use a 3300 XL 5mm or 8mm probe and extension cable that combine for a total electrical length of 9.0 metres to maintain calibration integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the -CN suffix affect international compliance?\u003c\/strong\u003eThe -CN suffix ensures the device is legal for installation within the People's Republic of China, meeting local explosive safety (NEPSI) and mandatory certification (CCC) laws. It is functionally equivalent to global 3300 XL sensors but carries the required local labeling and documentation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines and Safety Maintenance\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore installation, verify the shaft material metallurgy. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD 145004-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically for Ni-Cr-Mo-V. Using this sensor on 4140 steel or other alloys will result in incorrect vibration readings. Reference the job number (162282) and CT-0069 target code for your facility's asset records.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Zeroing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring commissioning, set the probe gap to achieve the electrical zero of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-3.0 VDC @ 20 mils\u003c\/strong\u003e. This ensures the measurement stays within the optimized linear range of the 3300 XL system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the DIN rail is properly bonded to the instrument earth. While the Proximitor housing is designed for isolation, proper rack grounding is essential to maintain the CCC\/SRRC electromagnetic compatibility standards and prevent signal noise in high-frequency switching environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor NEPSI-certified installations, ensure all cable glands and conduit seals meet the local explosion-proof requirements. Modification of the PWA (as specified in BOM 145004) must only be performed by Bently Nevada factory-authorized service centers to maintain the safety rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666564903275,"sku":"330180-X1-CN MOD 1450004-82","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-cn-mod-1450004-82-proximity-transducer-system-cuh4jpwij4o_a8068a52-102a-4284-8dbf-327a8ca368db.jpg?v=1765440720"},{"product_id":"bently-nevada-330881-28-04-70-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-70-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (multiple approvals 3300 XL probe) and Option 03 (one M20 fitting) specify this metric PROXPAC XL configuration — \u003cstrong\u003e330881-28-04-70-03-02\u003c\/strong\u003e. This metric-threaded \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly is equipped with a 40 mm standoff adapter (Option 04), a 70 mm probe penetration length (Option 70), and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\u003cp\u003eThis integrated assembly combines a 3300 XL 8 mm proximity probe and its associated 3300 XL Proximitor sensor directly into a single glass-reinforced polyphenylene sulfide (PPS) thermoplastic enclosure. By eliminating the necessity for a separate Proximitor sensor housing or an external extension cable, the 330881 system significantly simplifies industrial field installation, reduces wiring complexity, and forms a durable, self-contained eddy-current measurement system. The metric 330881 variant relies on metric conduit fittings (M20 or M25) and metric probe sleeve adjustments, distinguishing it from English-threaded 330880 models.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 probe and approvals: Integrates a 3300 XL 8 mm proximity probe certified with multiple hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 04 standoff: Features a 40 mm standoff adapter to adjust probe positioning.\u003c\/li\u003e\n  \u003cli\u003eOption 70 penetration: Provides a 70 mm probe penetration depth.\u003c\/li\u003e\n  \u003cli\u003eOption 03 conduit fitting: Includes one M20 conduit fitting and two blanking plugs for secure cable routing.\u003c\/li\u003e\n  \u003cli\u003eOption 02 mounting thread: Uses a standard 3\/4-14 NPT mounting thread for standoff adapter engagement.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Proximitor: Houses a 1-metre 3300 XL Proximitor sensor directly in the housing lid, eliminating separate extension cables.\u003c\/li\u003e\n  \u003cli\u003eAdvanced PPS housing: Molded glass-reinforced polyphenylene sulfide housing provides chemical resistance and static dissipation.\u003c\/li\u003e\n  \u003cli\u003eHigh environmental protection: Enclosure is rated for Type 4X and IP66 environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUsed for non-contact shaft vibration and axial position measurements on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eIdeal for severe industrial environments including oil and gas facilities, petrochemical plants, and power generation turbines.\u003c\/li\u003e\n  \u003cli\u003eSimplifies installation in locations where mounting separate Proximitor sensors in external enclosures is impractical or costly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-28-04-70-03-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n      \u003ctd\u003e70\u003c\/td\u003e\n      \u003ctd\u003e70 mm probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-04-70-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMetric Integrated Proximity Transducer Assembly (PROXPAC XL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-metre cable length (Option 28, multiple approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from DSL\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB) with up to 305 metres of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGlass-reinforced polyphenylene sulfide (PPS) with conductive fibers (UV resistant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Metal Parts\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 and AISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eO-ring Seals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene (sleeve-to-housing), Viton (probe tip-to-case pressure seal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when properly sealed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eField wiring connects directly inside the PROXPAC XL enclosure to the integrated terminal block, eliminating the need for an external extension cable. Terminal block interface specifications:\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Symbol\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eRecommended Connection\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003ePower Supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n      \u003ctd\u003eField wiring power lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eTransducer Signal Output\u003c\/td\u003e\n      \u003ctd\u003eField wiring signal lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Signal Ground\u003c\/td\u003e\n      \u003ctd\u003eField wiring common lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n  \u003cli\u003eWire Size Compatibility: 0.2 to 1.5 mm2 (16 to 24 AWG)\u003c\/li\u003e\n  \u003cli\u003eRecommended Cable: 3-conductor twisted shielded cable with drain wire\u003c\/li\u003e\n  \u003cli\u003eMaximum Distance: Up to 305 metres (1000 feet) to the monitoring system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMounting: Mount the assembly via the 3\/4-14 NPT outer thread (Option 02) onto the machine casing. Use the standoff adapter to adjust the probe positioning relative to the target surface.\u003c\/li\u003e\n  \u003cli\u003eProbe Gap: Set the initial probe gap to approximately 1.27 mm (50 mils) corresponding to -10.0 Vdc output at the center of the linear range.\u003c\/li\u003e\n  \u003cli\u003eSleeve Adjustment: The threaded sleeve allows +\/-12.7 mm (+\/-0.5 in) of adjustment to achieve the correct gap during installation.\u003c\/li\u003e\n  \u003cli\u003eCondensation Control: Seal all conduit entries with the provided blanking plugs or conduit fittings. Ensure that field wiring cables loop downward before entering the enclosure to prevent moisture from running into the housing through the conduit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark: Complies with European CE directives.\u003c\/li\u003e\n  \u003cli\u003eIP Rating: IP66 and Type 4X rating verified for environmental seal.\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals: Option 28 probe is certified with multiple international hazardous area agency approvals (including ATEX, IECEx, and CSA) for intrinsically safe installations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565067115,"sku":"330881-28-04-70-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-70-03-02-proxpac-xl-proximity-transducer-ywk4qcs55ly_eef74032-749d-43f5-8be0-955f13974bb1.jpg?v=1765440724"},{"product_id":"bently-nevada-330780-51-05-3300-xl-11-mm-proximitor-sensor","title":"Bently Nevada 330780-51-05 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 51 (5.0 meter system length, DIN mount) and Option 05 (Multiple Approvals) specify this 3300 XL 11 mm Proximitor Sensor configuration — \u003cstrong\u003e330780-51-05\u003c\/strong\u003e. The 3300 XL 11 mm system features an incremental scale factor of 3.94 V\/mm (100 mV\/mil) for non-contact displacement and vibration measurements. The system is used on fluid-film bearing machines where an extended linear range is required, including turbine axial (thrust) position, ramp differential expansion, and reciprocating compressor rod drop monitoring.\u003c\/p\u003e\n\u003cp\u003eThis 330780-51-05 sensor processes the RF signal from a compatible 3300 XL 11 mm proximity probe and extension cable, outputting a voltage signal proportional to the distance between the probe tip and the observed shaft surface. The unit mounts on standard 35 mm DIN rails and is compatible with 3500 series machinery protection systems and secondary monitors.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 51 specifies a 5.0 meter (16.4 feet) system length combined with an integrated DIN-mount physical layout.\u003c\/li\u003e\n  \u003cli\u003eOption 05 delivers multiple international hazardous area agency approvals including ATEX, IECEx, and CSA.\u003c\/li\u003e\n  \u003cli\u003eGenerates a linear range of 4.0 mm (160 mils) for reliable tracking of larger rotor and shaft movements.\u003c\/li\u003e\n  \u003cli\u003eProvides an output scale factor of 3.94 V\/mm (100 mV\/mil) with high accuracy and low thermal drift.\u003c\/li\u003e\n  \u003cli\u003eEncased in an A380 aluminum housing for high mechanical integrity and environmental protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 330780-51-05 Proximitor Sensor is used in rotating machinery monitoring where an extended linear range is required. Typical application areas include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine axial (thrust) position and ramp differential expansion tracking\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor rod position and rod drop measurements\u003c\/li\u003e\n  \u003cli\u003eHigh-speed industrial turbine and compressor shaft vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eTachometer, phase reference (Keyphasor), and zero speed signal generation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe 330780-51-05 Proximitor Sensor is configured using the following structured options:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330780-51-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Total Length and Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e51\u003c\/td\u003e\n      \u003ctd\u003e5.0 meter (16.4 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e330780-51-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer System Type\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), beginning at approximately 0.5 mm (20 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eScale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10% (including interchangeability error)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Requirement\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Length Compatibility\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003eTested to IEC 68-2-3 damp heat\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz: +0, -3 dB typical (with up to 305 meters of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminal Blocks Torque Limit\u003c\/td\u003e\n      \u003ctd\u003e0.565 N-m (5 in-lb) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProximitor Weight\u003c\/td\u003e\n      \u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePhysical Dimensions (Option 51)\u003c\/td\u003e\n      \u003ctd\u003e31.7 mm x 70.8 mm x 89.4 mm (1.25 in x 2.79 in x 3.52 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003ePower Supply input\u003c\/td\u003e\n      \u003ctd\u003eNegative voltage supply (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon\u003c\/td\u003e\n      \u003ctd\u003eSystem common reference ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eSignal Output\u003c\/td\u003e\n      \u003ctd\u003eProportional dynamic voltage output (3.94 V\/mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation ensures stable, noise-free vibration and position data. Observe the following guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount on a standard 35 mm DIN rail. Ensure a physical clearance of at least 3.05 mm (0.12 in) is maintained above and below the mounting pad to allow easy removal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect using 0.2 to 1.5 mm2 (16 to 24 AWG) shielded three-conductor triad field wiring. Keep field wiring length under 305 meters (1000 feet) to prevent high-frequency signal attenuation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper shield terminal grounding at the monitor side only. Do not double-ground.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e If terminals are exposed to direct moisture or dust, the Proximitor must be installed within a protective enclosure providing at least IP54 protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330780-51-05 Proximitor Sensor has option 05 approvals, which verify compliance with multiple standard requirements:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Intrinsically Safe (Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc) and Non-Sparking\/Ec (Ex nA\/ec IIC T5...T1 Gc)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American (cNRTLus):\u003c\/strong\u003e Class I, Zone 0, AEx\/Ex ia IIC T4\/T5 Ga; Class I, Div 1, Groups A, B, C, D; Class I, Div 2, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions), CE compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (HFT = 0), SIL 3 compliant (HFT = 1)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with European Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565525867,"sku":"330780-51-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330780-51-05-3300-xl-11-mm-proximitor-sensor-dsdxsfliceq_4954eac2-4609-4073-b5a1-d5d247fbadeb.jpg?v=1765440728"},{"product_id":"bently-nevada-330180-x1-05mod-145347-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05MOD:145347-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-X1-05MOD:145347-05\u003c\/strong\u003e specifies this customized 3300 XL \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e configuration, featuring the X1 DIN-rail mount modification, standard Agency Approval Option 05, and a specialized target material calibration under Modification 145347 (Option 05).\u003c\/p\u003e\n\u003cp\u003eThis customized Proximitor sensor is calibrated as part of a specialized modification chain to ensure precise shaft vibration and axial position tracking when paired with 3300 XL 5 mm or 8 mm proximity probes and 9-meter extension cables. By departing from standard AISI 4140 steel calibration, this sensor corrects for the specific electrical conductivity and magnetic permeability of alternative rotor metallurgy, delivering a linear voltage output in critical turbomachinery applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDIN-Rail Mounting (X1 Option): Pre-configured with a secure mounting clip for direct installation onto standard 35 mm DIN rails, simplifying panel wiring.\u003c\/li\u003e\n  \u003cli\u003eMultiple Agency Approvals (Option 05): Certified for safe operation in hazardous industrial environments under ATEX, IECEx, and CSA standards.\u003c\/li\u003e\n  \u003cli\u003eCustom Target Calibration (Mod 145347-05): Adjusted circuit parameters to maintain scale factor accuracy over non-standard metallic targets.\u003c\/li\u003e\n  \u003cli\u003eSystem Integration: Houses the stable high-frequency oscillator and demodulator circuitry necessary to drive Bently Nevada eddy-current probes.\u003c\/li\u003e\n  \u003cli\u003eExcellent Noise Immunity: Designed with shielding and filtering that isolate the sensor output from electromagnetic and radio-frequency interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe sensor is ideal for turbomachinery monitoring in heavy-industry sectors such as oil and gas, petrochemicals, power generation, and water treatment. It is specifically applied where machinery shafts are composed of non-standard alloys rather than AISI 4140 steel, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine rotor displacement measurement\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor radial shaft vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eHigh-speed motor and pump axial thrust tracking\u003c\/li\u003e\n  \u003cli\u003eGearbox input and output shaft vibration diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment Code\u003c\/th\u003e\n      \u003cth\u003eThis SKU Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-X1-05MOD:145347-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 5mm\/8mm 9m Recalibrated Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment A: Total Length and Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eX1\u003c\/td\u003e\n      \u003ctd\u003eModification, DIN Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment B: Agency Approval and Mod Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05MOD:145347\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx) with custom recalibration modification family 145347\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment C: Target Material Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eOption 05 target material calibration under Modification 145347\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e330180-X1-05MOD:145347-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDevice Type\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 5 mm \/ 8 mm (9-Meter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Configuration\u003c\/td\u003e\n      \u003ctd\u003eDIN-rail mount (X1 option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approvals\u003c\/td\u003e\n      \u003ctd\u003eOption 05 (Multiple Approvals: CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e10 to 90 mils (0.25 to 2.25 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Scale Factor\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Zero (E-zero)\u003c\/td\u003e\n      \u003ctd\u003e-3.0 Vdc @ 20 mils\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-51 to 100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.2 mm x 104.1 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the Proximitor sensor is mounted in a dry, clean enclosure or weather-proof housing to prevent moisture ingress. Maintain proper DIN rail grounding to protect signal integrity. Secure probe and extension cable coaxial connections with connector protectors or self-coalescing tape to insulate them from structural ground paths. Shielded field wiring must run back to the monitoring system to eliminate electromagnetic coupling.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eWhen ordered with Option 05, this device is certified for installation in hazardous locations under multiple international schemes:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA: Intrinsically Safe (Class I, Div 1, Groups A, B, C, D) and Non-Incendive (Class I, Div 2)\u003c\/li\u003e\n  \u003cli\u003eATEX \/ IECEx: Ex ia IIC T4 Ga (Zone 0) and Ex nA IIC T4 Gc (Zone 2)\u003c\/li\u003e\n  \u003cli\u003eCE Mark compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565722475,"sku":"330180-X1-05 MOD：145347-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145347-05-proximitor-sensor-sxketajhwsi_93f19dd0-0daa-4f7c-9dd2-163af19d0e56.jpg?v=1765440733"},{"product_id":"bently-nevada-330881-16-00-395-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-16-00-395-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-16-00-395-06-02\u003c\/strong\u003e specifies a metric Bently Nevada PROXPAC XL integrated proximity transducer configuration, pairing a 3300 XL 8 mm proximity probe (Option 16) with a 395 mm probe penetration depth (Option 395). This self-contained, integrated assembly incorporates its own 3300 XL Proximitor sensor inside the housing lid, eliminating the need for an intermediate extension cable or a separate Proximitor enclosure. Field wiring connects directly between the monitors and the terminal strip inside the housing, reducing installation complexity and wiring interfaces.\u003c\/p\u003e\n\u003cp\u003eThis configuration operates without an external standoff adapter (Option 00) and features a 3\/4-14 NPT mounting thread (Option 02). It is supplied with a fittings kit (Option 06) containing one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two plugs. The housing is constructed of glass-reinforced, conductive-fiber-filled polyphenylene sulfide (PPS) thermoplastic, which resists chemical exposure, provides IP66 and Type 4X sealing, and dissipates electrostatic charges. Because this unit is ordered with Option 16, it is supplied without hazardous area agency approvals.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 16 integrates a 3300 XL 8 mm proximity probe without hazardous area approvals.\u003c\/li\u003e\n\u003cli\u003eOption 00 configures the transducer assembly without an external standoff adapter.\u003c\/li\u003e\n\u003cli\u003eOption 395 provides a deep 395 mm probe penetration length for machinery cases.\u003c\/li\u003e\n\u003cli\u003eOption 06 includes a metric\/NPT fittings kit with one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two plugs.\u003c\/li\u003e\n\u003cli\u003eOption 02 provides a 3\/4-14 NPT mounting thread.\u003c\/li\u003e\n\u003cli\u003eSelf-contained design locates the Proximitor sensor in the housing lid, eliminating remote sensor enclosures and separate extension cables.\u003c\/li\u003e\n\u003cli\u003ePolyphenylene sulfide (PPS) housing material offers chemical resistance and resists electrostatic charge accumulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and axial position measurement on industrial rotating machinery.\u003c\/li\u003e\n\u003cli\u003eDirect-mount external casing probe installations where separate Proximitor housings are impractical.\u003c\/li\u003e\n\u003cli\u003eSevere-environment machinery monitoring requiring IP66 and Type 4X environmental protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe 330881-16-00-395-06-02 represents a specific orderable configuration of the metric PROXPAC XL Proximity Transducer Assembly. The table below decodes each option segment of this SKU:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Selection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe without approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e395\u003c\/td\u003e\n\u003ctd\u003e395 mm penetration length (increments of 1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread (required if ordering Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter \/ Category\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n\u003ctd\u003e330881-16-00-395-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Family\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Sensor Input\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils), beginning at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% under standard conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/- 0.025 mm (+\/- 1 mil) over the linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Rating\u003c\/td\u003e\n\u003ctd\u003eIP66 and Type 4X (hose-directed water seal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve \u0026amp; Retaining Chain Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sleeve \u0026amp; Retaining Screws\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Liner Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetaining Nut Torque\u003c\/td\u003e\n\u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Sleeve Locknut Torque\u003c\/td\u003e\n\u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing \u0026amp; Proximitor Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the target shaft or surface meets the minimum target diameter of 15.2 mm (0.6 in) to achieve full linear calibration.\u003c\/li\u003e\n\u003cli\u003eTo prevent measurement cross-talk, maintain a minimum separation of 40 mm (1.6 in) for axial position measurements and 38 mm (1.5 in) for radial vibration measurements.\u003c\/li\u003e\n\u003cli\u003eDo not expose the probe to temperatures below -34 degC (-29 degF) during operation to avoid premature failure of the pressure seal.\u003c\/li\u003e\n\u003cli\u003eTorque the probe sleeve locknut to 39.3 N-m (350 in-lb) and the housing retaining nut to 29.5 N-m (260 in-lb) during final physical mounting.\u003c\/li\u003e\n\u003cli\u003eSeal all conduit entries and utilize the supplied fittings (Option 06) to prevent moisture or condensation from traveling through the conduit into the housing cavity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with European CE mark.\u003c\/li\u003e\n\u003cli\u003eHousing IP66 rating verified by BASEEFA report number T07\/0709.\u003c\/li\u003e\n\u003cli\u003eNote: Because this specific assembly is configured with Option 16, it does not come with hazardous area agency approvals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566213995,"sku":"330881-16-00-395-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-16-00-395-06-02-proxpac-xl-proximity-transducer-c1okvqdzaiy_4ea0eb10-7b60-47e2-9295-845d1b192431.jpg?v=1765440743"},{"product_id":"bently-nevada-330881-br-04-034-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-034-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies INMETRO (Brazilian) approvals and a 3300 XL 8 mm probe configuration for this metric PROXPAC XL integrated transducer assembly — \u003cstrong\u003e330881-BR-04-034-06-02\u003c\/strong\u003e. This configuration integrates a metric PROXPAC XL housing, a 40 mm standoff adapter (Option 04), and a custom 34 mm probe penetration length (Option 034). The assembly features a heavy-duty sealing kit under Option 06, which provides one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT stainless steel reducer, and two plugs. The entire unit is designed to mount via a 3\/4-14 NPT thread (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eBy housing both a 1-metre 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor within a single self-contained housing, the \u003cstrong\u003e330881-BR-04-034-06-02\u003c\/strong\u003e eliminates the need for external extension cables and standalone Proximitor housings. This design directly reduces connection points, minimizes signal degradation, and simplifies wiring layouts by bringing field connections directly to the monitor. The housing is constructed from Polyphenylene Sulfide (PPS) molded thermoplastic reinforced with glass and conductive fibers, which provides Type 4X and IP66 environmental protection while safely dissipating electrostatic charges.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption BR: Features an integrated 3300 XL 8 mm proximity probe certified with INMETRO (Brazilian) hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 04: Features a metric standoff adapter with a specific length of 40 mm.\u003c\/li\u003e\n  \u003cli\u003eOption 034: Configured with a precise 34 mm probe penetration length.\u003c\/li\u003e\n  \u003cli\u003eOption 06: Includes one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT stainless steel reducer, and two plugs to secure the conduit interface.\u003c\/li\u003e\n  \u003cli\u003eOption 02: Standard 3\/4-14 NPT mounting thread configuration, required to support standoff adapter options.\u003c\/li\u003e\n  \u003cli\u003eConductive PPS Housing: Thermoplastic material design provides defense against corrosive chemical environments and dissipates static charges.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Architecture: Built-in Proximitor sensor eliminates the traditional probe-to-sensor extension cable for a more direct signal path.\u003c\/li\u003e\n  \u003cli\u003eType 4X and IP66 Enclosure: Rated for direct hose-directed water exposure and harsh industrial locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDynamic shaft vibration monitoring on critical rotating machinery\u003c\/li\u003e\n  \u003cli\u003eRotor axial position and thrust movement measurement\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor piston rod position and rod runout wear monitoring\u003c\/li\u003e\n  \u003cli\u003eShaft radial displacement and casing thermal expansion detection\u003c\/li\u003e\n  \u003cli\u003eApplications in petrochemical, refining, and power generation facilities requiring INMETRO hazardous area certifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Configuration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-034-06-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBR\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazilian) Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length (B Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e034\u003c\/td\u003e\n      \u003ctd\u003e34 mm probe penetration length (C Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-034-06-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils); begins at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage Output Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-1 Vdc to -17 Vdc nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMaximum 305 m (1,000 ft) between sensor and monitor using recommended 1.0 mm2 (18 AWG) 3-conductor shielded triax cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS) molded thermoplastic with glass and conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +177 degC (-60 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Material Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAdhering to these guidelines helps prevent common installation issues and maintains system integrity:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the 3\/4-14 NPT mounting threads are free of debris and properly matched before threading the standoff adapter into the machine casing.\u003c\/li\u003e\n  \u003cli\u003eEnsure the 8 mm probe tip maintains the recommended 1.27 mm (50 mils) gap to the target shaft for optimal linear range response.\u003c\/li\u003e\n  \u003cli\u003eRoute field wiring directly through the Option 06 fittings into the housing terminal block, securing the lid and lid screws to protect the internal Proximitor sensor from moisture and dust.\u003c\/li\u003e\n  \u003cli\u003eConfirm that the PPS housing's conductive fibers are grounded to allow effective dissipation of static electricity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eINMETRO Certifications: Intrinsically Safe (Ex ia IIC T4\/T5 Ga) and Non-sparking\/Increased safety (Ex nA\/Ex ec IIC T4\/T5 Gc) under Option BR.\u003c\/li\u003e\n  \u003cli\u003eEMC Directive: EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive: Compliant with European Union Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eMaritime Standards: Certified under major classification rules where applicable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566312299,"sku":"330881-BR-04-034-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-034-06-02-proxpac-xl-housing-5cr2o3zuqsg_8f42fd74-247b-49be-aa0f-7106e471e2a6.jpg?v=1765440745"},{"product_id":"bently-nevada-330881-28-6-155-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-6-155-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals), Option 6 (60 mm standoff adapter), Option 155 (155 mm probe penetration), Option 03 (one M20 fitting, two plugs), and Option 02 (3\/4-14 NPT mounting thread) specify this integrated metric proximity transducer configuration — \u003cstrong\u003e330881-28-6-155-03-02\u003c\/strong\u003e. The \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly functions as a completely self-contained proximity probe system, integrating both a 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor directly into a single molded thermoplastic housing. This integration removes the need for an external extension cable between the probe and Proximitor sensor, allowing field wiring to connect directly from the monitoring system to the assembly cover terminals.\u003c\/p\u003e\n\n\u003cp\u003eUnlike non-approved configurations or English thread variants such as the 330880 series, the 330881-28-6-155-03-02 configuration features a metric-focused layout with a 3\/4-14 NPT mounting thread required for its 60 mm standoff adapter. The integrated housing cover contains a Proximitor sensor with multiple international approvals, meeting intrinsically safe and non-incendive parameters for hazardous areas. The body is molded from ultraviolet-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers to dissipate electrostatic charges, providing a Type 4X and IP66 rating for severe industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 28 integration includes a 3300 XL 8 mm proximity probe with Multiple Approvals.\u003c\/li\u003e\n\u003cli\u003eOption 6 provides a 60 mm standoff adapter for mounting adjustment.\u003c\/li\u003e\n\u003cli\u003eOption 155 specifies a 155 mm metric probe penetration length.\u003c\/li\u003e\n\u003cli\u003eOption 03 supplies one M20 conduit fitting and two plugs.\u003c\/li\u003e\n\u003cli\u003eOption 02 utilizes a 3\/4-14 NPT mounting thread, required when using the standoff adapter.\u003c\/li\u003e\n\u003cli\u003eSelf-contained design contains both the probe and Proximitor sensor in one housing, eliminating separate extension cabling.\u003c\/li\u003e\n\u003cli\u003ePolyphenylene sulfide (PPS) thermoplastic housing is glass-reinforced and conductive-fiber filled to withstand harsh chemical contact and electrostatic buildup.\u003c\/li\u003e\n\u003cli\u003eIP66 and Type 4X environmental ratings seal against dust and hose-directed water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 330881-28-6-155-03-02 is used for rotating machinery protection, particularly where space constraints or harsh outdoor conditions make running long extension cables impractical. Typical applications include shaft vibration and axial position measurements on steam turbines, gas turbines, compressors, pumps, and gearboxes in power generation, chemical processing, and oil and gas facilities. It is suitable for hazardous environments where intrinsically safe or non-incendive certifications are required.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption \/ Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-6-155-03-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option (B Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e60 mm Standoff Adapter length (order in increments of 10 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option (C Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003ctd\u003e155 mm Probe Penetration length (order in increments of 1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (required when ordering Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-6-155-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe with 1-metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target (from 0.25 to 2.3 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-5% over 80 mil linear range (0 degC to +45 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Diameter Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in) minimum; 76.2 mm (3.0 in) recommended minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel with retaining chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66 and Type 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRetaining Nut Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Sleeve Locknut Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe integrated design of the PROXPAC XL series simplifies wiring. Field wiring connections must be routed through the conduit entry. Utilize the supplied M20 fitting (Option 03) to maintain proper housing seals. Field wire size of 0.2 to 1.5 mm2 (16 to 24 AWG) is recommended, using a 3-conductor shielded triaxial cable. For grounding, ensure the internal grounding liner is securely connected, and route the drain wire according to the system's wiring layout. Take proper precautions to prevent moisture ingress through the conduit into the PPS housing.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330881-28-6-155-03-02 features multiple international hazardous area certifications (Option A = 28):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus:\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, and D; Class II, Groups E, F, and G; Class III. Non-incendive Class I, Division 2, Groups A, B, C, and D; Class I, Zone 2: AEx\/Ex nA\/ec IIC T4\/T5 Gc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Intrinsically safe II 1 G Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc. Non-sparking\/ec II 3 G Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with European electromagnetic compatibility and electrical safety directives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Enclosure certified for IP66 and Type 4X.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566476139,"sku":"330881-28-6-155-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-6-155-03-02-proxpac-xl-housing-g2y0go4m5tf_0d98e7f6-174e-48c6-9994-12720d6ec05b.jpg?v=1765440750"},{"product_id":"bently-nevada-330881-16-00-060-01-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-16-00-060-01-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-16-00-060-01-02\u003c\/strong\u003e specifies a metric \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e configuration engineered with a 3300 XL 8 mm probe without hazardous area approvals (Option 16). This specific transducer assembly eliminates the standoff adapter (Option 00) and is optimized with a 60 mm probe penetration sleeve (Option 060), a metric Fittings kit containing one M25 fitting and two plugs (Option 01), and a 3\/4-14 NPT mounting thread (Option 02). By integrating both the proximity probe and the Proximitor sensor into a single, advanced Polyphenylene Sulfide (PPS) housing, this self-contained design simplifies field installations and eliminates the need for separate extension cables and dedicated Proximitor enclosures.\u003c\/p\u003e\n\n\u003cp\u003eUnlike hazardous-area configurations utilizing Option 28 (which includes multiple safety certifications), this Option 16 model is designed specifically for general-purpose, non-hazardous industrial environments, offering a cost-effective solution for safe-area machinery monitoring. The 60 mm penetration sleeve length provides a compact casing reach ideal for shallow-to-medium machinery housing depth configurations, while the M25 metric fittings and 3\/4-14 NPT thread allow rigid, environmentally sealed connections directly to the machine casing and standard conduit networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Enclosure Design:\u003c\/strong\u003e Houses both the 3300 XL 8 mm probe and the Proximitor sensor inside a single cover, removing intermediate cabling and reducing field wiring connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 16 Probe System:\u003c\/strong\u003e Incorporates a standard-performance 3300 XL 8 mm proximity probe configured for safe, non-hazardous areas.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e60 mm Metric Penetration (Option 060):\u003c\/strong\u003e Medium sleeve penetration length allows precise gapping and protective isolation of the probe case.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo Standoff Adapter (Option 00):\u003c\/strong\u003e Configured for direct casing mount without standoff clearance requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOne M25 Fitting Kit (Option 01):\u003c\/strong\u003e Includes one metric M25 cable conduit fitting and two blanking plugs for reliable environmental sealing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged PPS Housing:\u003c\/strong\u003e Glass-reinforced, conductive-fiber-filled Polyphenylene Sulfide thermoplastic enclosure provides excellent structural integrity, dissipates electrostatic charges, and resists corrosive environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP66 and Type 4X Rating:\u003c\/strong\u003e Certified to seal effectively against ingress from dust and high-pressure hose-directed water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical applications include radial shaft vibration, axial position, and speed measurements on rotating machinery situated in non-hazardous plant sections. This transducer is widely used on industrial pumps, fans, compressors, small steam turbines, and blowers where physical space constraints prevent the installation of separate, external Proximitor housing boxes.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-16-00-060-01-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe without approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e60 mm probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eOne M25 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Sensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe (1-metre length) installed in sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), begins at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGlass-reinforced, UV-resistant, conductive-fiber-filled Polyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor and Housing Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when properly sealed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and NEMA Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Setting Check:\u003c\/strong\u003e Verify the target gap is set to approximately 1.27 mm (50 mils), corresponding to an output voltage of -10.0 Vdc, to align measurements in the center of the linear calibration band.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSleeve Support Rule:\u003c\/strong\u003e If the total length of the sleeve exceeds 305 mm (12 in), additional physical supports or clamping should be used close to the probe head to prevent mechanical resonance and ensure probe stability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMoisture Ingress Prevention:\u003c\/strong\u003e Ensure that all cover gaskets, plug threads, and conduit entries are fully sealed. Users must take adequate steps to prevent condensation from traveling down conduit lines into the housing terminal area.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Specifications:\u003c\/strong\u003e Utilize 0.2 to 1.5 mm2 (16 to 24 AWG) 3-conductor shielded triaxial cable. Keep the run distance below 305 m (1000 ft) to preserve full dynamic frequency response.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with European EMC Directive 2014\/30\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Verification:\u003c\/strong\u003e IP66 verified by BASEEFA under report T07\/0709\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Rating:\u003c\/strong\u003e This Option 16 configuration does not carry hazardous-area certification. Designed for safe areas only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666567852395,"sku":"330881-16-00-060-01-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-16-00-060-01-02-proxpac-xl-proximity-transducer-mnnqimf34nk_201f95be-065e-4589-9ad4-1c39dd6d0845.jpg?v=1765440779"},{"product_id":"bently-nevada-330878-91-05-3300-xl-50-mm-proximitor-sensor","title":"Bently Nevada 330878-91-05 3300 XL 50 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 91 (9.0 meters system length, DIN mount) and Option 05 (Multiple Approvals) specify this 3300 XL 50 mm Proximitor Sensor configuration — \u003cstrong\u003e330878-91-05\u003c\/strong\u003e. This unit works with a 3300 XL 50 mm proximity probe and extension cable as part of a complete non-contact eddy-current displacement measurement system. It is used for shaft vibration and axial position measurement on large turbine rotors and machinery with oversized targets where displacement ranges exceed standard limits.\u003c\/p\u003e\n\u003cp\u003eUnlike variants configured for panel mounting (such as Option 90) or shorter 5.0-meter system lengths (such as Option 51), this specific configuration is tailored for DIN rail installation with a total system length of 9.0 meters. The integrated SpringLoc terminal strips facilitate fast field wiring connections without requiring specialized tools. Improved radio frequency interference (RFI) and electromagnetic interference (EMI) immunity allow this sensor to meet CE marking standards without specialized shield housing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 91 specifies a 9.0-meter system calibration designed for DIN rail mounting configurations.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides multiple agency approvals including ATEX, IECEx, and CSA hazardous area certifications.\u003c\/li\u003e\n  \u003cli\u003eExtended linear range of 27.9 mm (1100 mils) starting at 1.3 mm (50 mils) from the target.\u003c\/li\u003e\n  \u003cli\u003eAverage Scale Factor (ASF) of 394 mV\/mm (10 mV\/mil) nominal for high-displacement environments.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal strips simplify connection procedures and resist loosening under vibration.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in test points allow signal verification using standard instruments without interrupting field wiring.\u003c\/li\u003e\n  \u003cli\u003eBackward compatibility with standard 3300 XL 50 mm proximity probes and extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine generator set differential expansion (DE) monitoring\u003c\/li\u003e\n  \u003cli\u003eLarge industrial gas turbine rotor position measurements\u003c\/li\u003e\n  \u003cli\u003eAxial displacement monitoring on oversized shaft assemblies\u003c\/li\u003e\n  \u003cli\u003eHigh-displacement target tracking in power generation and petrochemical facilities\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery with heavy vibration and environmental exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330878-91-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximitor Sensor, DIN mount, 9.0 m system length, multiple approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e91\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx, etc.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-91-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one 3300 XL 50 mm proximity probe and extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length Calibration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers), 12 mA maximum consumption; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e27.9 mm (1100 mils), from approximately 1.3 mm to 29.2 mm (50 to 1150 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e394 mV\/mm (10 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.74 mm (+\/-29 mils) within 0 degC to +45 degC range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpringLoc terminal strip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupported Field Wiring Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eProximitor voltage output signal (dynamic and DC gap)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon circuit return reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e-VT\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDIN rail mounting utilizes the integrated DIN pad designed for a standard 35 mm DIN rail. Allow an additional 3.05 mm of clearance to remove the module from the rail.\u003c\/li\u003e\n  \u003cli\u003eGround the shield of the extension cable at the Proximitor Sensor housing. Do not ground the coaxial shield at any other point to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003eUse recommended three-conductor shielded triad field cable (18 AWG or similar) for runs from the Proximitor Sensor to the monitor rack.\u003c\/li\u003e\n  \u003cli\u003eMaintain minimum target size requirements of 102 mm (4.0 inches) flat target diameter when verifying system calibration.\u003c\/li\u003e\n  \u003cli\u003eCalibrate the probe gap using the physical movement of a sliding bracket or spindle micrometer prior to locking the case threads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX\/IECEx: Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc, Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc (Option 05)\u003c\/li\u003e\n  \u003cli\u003eCSA\/CNRTLus: Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n  \u003cli\u003eEuropean CE Mark: Compliant with EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eElectromagnetic Compatibility Standards: EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n  \u003cli\u003eChina RoHS: 15-year Environment Friendly Use Period (EFUP)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666570998123,"sku":"330878-91-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330878-91-05-proximitor-sensor-p4h5thnndfr_6157fe43-0bed-4238-a4c9-e944da3ab6b9.jpg?v=1765440837"},{"product_id":"bently-nevada-330881-28-20-040-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-20-040-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-20-040-03-02\u003c\/strong\u003e: Metric \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly featuring a 3300 XL 8 mm proximity probe with Multiple Approvals, a 200 mm standoff adapter, a 40 mm probe penetration depth, a single M20 fitting option, and a 3\/4-14 NPT mounting thread.\u003c\/p\u003e\n\u003cp\u003eThis integrated design combines the transducer probe and the 3300 XL Proximitor sensor into a single Polyphenylene Sulfide (PPS) thermoplastic housing. By housing the Proximitor directly at the measurement point, this assembly eliminates the need for a separate extension cable and external Proximitor enclosure, allowing field wiring to connect directly from the machinery monitor. The PPS plastic housing is glass- and conductive-fiber-reinforced to provide electrostatic charge dissipation and is rated for Type 4X and IP66 severe environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 integrates a 3300 XL 8 mm proximity probe with multiple international hazardous area certifications (CSA, ATEX, IECEx).\u003c\/li\u003e\n  \u003cli\u003eOption 20 provides a 200 mm standoff adapter constructed of stainless steel.\u003c\/li\u003e\n  \u003cli\u003eOption 040 defines a 40 mm probe penetration depth for insertion into the machine casing.\u003c\/li\u003e\n  \u003cli\u003eOption 03 includes a single M20 fitting kit with two blanking plugs to seal unused conduit entries.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides a 3\/4-14 NPT mounting thread, which is required for the standoff adapter installation.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Proximitor sensor design removes the need for high-frequency coaxial extension cables, reducing installation labor.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene Sulfide (PPS) housing construction offers high impact strength and resistance to corrosive process fluids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL assembly is used for non-contact shaft vibration and axial position measurements on rotating machinery such as steam turbines, gas turbines, compressors, pumps, and gearboxes. It is suitable for applications where space is limited, hazardous area certifications are required, or where eliminating separate extension cables and external Proximitor housings reduces overall installation complexity and maintenance overhead.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-28-20-040-03-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA: Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB: Standoff Adapter Option\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e200 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC: Probe Penetration Option\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e40 mm probe penetration depth\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD: Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE: Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required when ordering Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-20-040-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Probe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 +\/- 0.50 Ohm (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG). Supports up to 305 metres (1,000 feet) between Proximitor and monitor. Standard 3-conductor shielded triax recommended.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target (0.25 mm to 2.3 mm; approx -1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% over the linear range from 0 degC to +45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil) from 0 degC to +45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres (1,000 feet) of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case \u0026amp; Sleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve \u0026amp; Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGrounding Liner Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing IP \/ Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66 rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper grounding continuity through the internal grounding liner and retaining plate. Run field wiring with high-quality 3-conductor shielded cable and tie down the drain wire appropriately.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Set the initial probe gap to the recommended 1.27 mm (50 mils) to center the measurement within the linear range of -1 Vdc to -17 Vdc.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Tighten the retaining nut to 29.5 N-m (260 in-lb). Torque the probe sleeve locknut to 39.3 N-m (350 in-lb) to maintain secure placement and casing seals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Bracing:\u003c\/strong\u003e Since the combined standoff (\"B\" dimension) and penetration (\"C\" dimension) lengths total 240 mm, ensure the probe sleeve is properly supported if subjected to heavy system vibration or if adjacent piping exerts physical resonance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMoisture Control:\u003c\/strong\u003e Seal all unused electrical entries on the PPS housing using the supplied blanking plugs. Ensure that conduit paths do not carry moisture from the exterior environment into the terminal box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with European EMC Directive 2014\/30\/EU (EN 61000-6-2 and EN 61000-6-4 standards).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 28):\u003c\/strong\u003e Certified for intrinsically safe and non-incendive installations under CSA (Class I, Div 1 \u0026amp; 2, Groups A, B, C, D) and ATEX\/IECEx (Ex ia IIC T5...T1 Ga, Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine Certifications:\u003c\/strong\u003e Approved in accordance with standard rules for offshore structures and marine conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572341611,"sku":"330881-28-20-040-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-20-040-03-02-sensor-proximity-tftx4sgmviu_bb5b16bf-f42a-49f2-af12-6d0743080571.jpg?v=1765440862"},{"product_id":"bently-nevada-330881-28-09-080-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-09-080-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-09-080-03-02\u003c\/strong\u003e: Metric PROXPAC XL Proximity Transducer featuring a 3300 XL 8 mm probe with multiple hazardous area approvals (Option 28), a 90 mm standoff adapter (Option 09), an 80 mm probe penetration length (Option 080), M20 fitting options (Option 03), and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eThis self-contained proximity transducer assembly combines the proximity probe and the 3300 XL Proximitor sensor into a single, unified housing. By mounting the Proximitor sensor directly in the housing lid, the system eliminates the need for external extension cables and separate Proximitor enclosures, greatly simplifying field wiring and installation in tight machinery spaces. The rugged housing is constructed from advanced polyphenylene sulfide (PPS) thermoplastic reinforced with glass and conductive fibers to withstand severe environmental exposure while dissipating electrostatic charges.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3300 XL 8 mm Probe with Multiple Approvals (Option 28)\u003c\/strong\u003e provides trusted eddy-current displacement measurements with global hazardous area certifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e90 mm Standoff Adapter (Option 09)\u003c\/strong\u003e provides the precise spacing required to position the probe body in your machinery case.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e80 mm Probe Penetration (Option 080)\u003c\/strong\u003e allows proper sleeve depth configuration for optimal mechanical clearance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle M20 Conduit Fitting (Option 03)\u003c\/strong\u003e provides safe, reliable cable entry and routing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3\/4-14 NPT Mounting Thread (Option 02)\u003c\/strong\u003e enables direct, secure mechanical installation of the outer sleeve assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Proximitor Sensor Design\u003c\/strong\u003e eliminates the intermediate extension cable, improving signal integrity and reducing loop connection points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlass-Reinforced PPS Housing\u003c\/strong\u003e provides Type 4X and IP66 protection against chemical washdown, moisture, and corrosive atmospheric environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eSpace-constrained applications where a separate Proximitor housing is not feasible.\u003c\/li\u003e\n  \u003cli\u003eCorrosive and harsh industrial environments, such as petrochemical plants, gas turbines, and water treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eHazardous area machinery monitoring requiring intrinsic safety or non-incendive approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-09-080-03-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e09\u003c\/td\u003e\n      \u003ctd\u003e90 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e080\u003c\/td\u003e\n      \u003ctd\u003e80 mm probe penetration depth\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required for standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-09-080-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe (with 1-metre cable inside sleeve)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Monitoring Inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUV-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eO-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene (sleeve to housing), Viton (inside probe case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Fittings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOne M20 conduit fitting and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandoff Adapter Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e90 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Penetration Depth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X, IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing\/Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 percent condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding\u003c\/strong\u003e: Ensure correct grounding of the integrated shielding plate and terminal block. Prevent loops by grounding only at the monitor side or housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap Adjustment\u003c\/strong\u003e: Set probe gap to the mid-voltage point (typically -10 Vdc for a 3300 XL 8 mm system) during installation to allow full mechanical dynamic range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Seal\u003c\/strong\u003e: Use appropriate sealing compound on conduit connections to prevent moisture and condensation from traveling through the conduit into the housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits\u003c\/strong\u003e: Tighten probe sleeve locknuts to a maximum torque of 39.3 N-m (350 in-lb) and the retaining nut to 29.5 N-m (260 in-lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEuropean CE Mark\u003c\/strong\u003e: Compliant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIngress Protection\u003c\/strong\u003e: IP66 housing rating (verified by BASEEFA).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e: Intrinsic Safety (Ex ia) and Non-Incendive\/Increased Safety (Ex nA\/ec) certifications for multiple global agencies (including ATEX, IECEx, and CSA) as designated by Option 28.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572439915,"sku":"330881-28-09-080-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-09-080-03-02-proxpac-xl-proximity-transducer-wrm01prbjri_4de71eec-f246-4979-96cf-af77396ae17f.jpg?v=1765440863"},{"product_id":"bently-nevada-330878-90-05-3300-xl-50-mm-proximitor-sensor","title":"Bently Nevada 330878-90-05 3300 XL 50 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 90 (9.0 meters system length, panel mount) and Option 05 (Multiple Approvals) specify this \u003cstrong\u003e3300 XL 50 mm Proximitor Sensor\u003c\/strong\u003e configuration — \u003cstrong\u003e330878-90-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWhile DIN mount configurations (Option 91) and 5.0-meter systems (Option 50 or 51) are available, this panel-mount, 9.0-meter system matches 330876 probes and 330877 extension cables for longer transmission distances. The Multiple Approvals selection allows installation in designated hazardous environments where compliance is required. The sensor utilizes advanced eddy-current technology to process displacement signals from a 50 mm probe, rendering it highly effective for differential expansion (DE) or rotor expansion (RX) measurements on steam turbine generators.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length:\u003c\/strong\u003e Configured for a 9.0 m (29.5 ft) system length, providing compatibility with corresponding 50 mm probes and extension cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e Panel-mount physical design for secure attachment to mounting plates or internal enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approvals:\u003c\/strong\u003e Option 05 designates multiple global hazardous area certifications, including CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Built-in SpringLoc terminal strips provide fast, highly robust field connections without specialized tools.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRFI\/EMI Immunity:\u003c\/strong\u003e Robust design elements shield signal integrity against nearby high-frequency radio interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDifferential expansion (DE) measurement on utility steam turbine generators.\u003c\/li\u003e\n  \u003cli\u003eRotor expansion (RX) monitoring to track thermal growth differentials.\u003c\/li\u003e\n  \u003cli\u003eAxial position and displacement tracking in heavy industrial rotating machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-90-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, panel mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-90-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e27.9 mm (1100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBegins at 1.3 mm (50 mils) to 29.2 mm (1150 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e394 mV\/mm (10 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.74 mm (+\/-29 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Sensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one 3300 XL 50 mm proximity probe and extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Terminal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Field Wire Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-conductor shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n      \u003cth\u003eWiring Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 to -26 Vdc)\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Ground reference\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDynamic analog output voltage signal\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the Proximitor Sensor on a clean, flat surface using the standard panel-mount configuration holes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Ensure the field wiring shield is connected to the monitor common ground and insulated at the Proximitor end to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Connection:\u003c\/strong\u003e Depress the SpringLoc lever, insert the stripped conductor (0.2 to 1.5 mm2), and release to secure. No special tools are needed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Cable Bend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in) for coaxial and triaxial system cables to prevent signal loss or conductor damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCertification Body \/ Standard\u003c\/th\u003e\n      \u003cth\u003eApproval Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCE Mark\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eComplies with European Community Directive 2014\/30\/EU (EMC) and RoHS Directive 2011\/65\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Standards\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions) for Industrial Environments\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNorth American Approvals (cNRTLus)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T5...T1 Ga, Ex ia IIIC T90 degC...T280 degC Dc; Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2019 Rules for Conditions of Classification\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572603755,"sku":"330878-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330878-90-05-proximitor-sensor-gwpqylptnek_75a84746-c19c-440e-9220-efa4c992eccd.jpg?v=1765440866"},{"product_id":"bently-nevada-330180-x1-05-mod-145004-47-3300-xl-5mm-8mm-proximitor-sensor","title":"Bently Nevada 330180-X1-05 MOD 145004-47 3300 XL 5mm\/8mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330180-X1-05\u003c\/strong\u003e with modification code \u003cstrong\u003e145004-47\u003c\/strong\u003e is a proximity sensor conditioning device engineered for non-contact vibration, position, and displacement measurements. This \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e is calibrated to accommodate alternative target materials other than standard 4140 steel, generating a linear voltage output proportional to the gap between the probe tip and the target surface. The device serves as a primary component within proximity probe systems, interfacing directly with machinery monitoring platforms to track shaft dynamics and position in critical rotating machinery applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecialized target material recalibration under modification 145004-47\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy conversion of eddy-current probe impedance variation to stable DC voltage\u003c\/li\u003e\n\u003cli\u003eInteroperability with specific 5mm and 8mm proximity probe configurations\u003c\/li\u003e\n\u003cli\u003eRobust mechanical housing designed for harsh industrial deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact shaft vibration and displacement monitoring\u003c\/li\u003e\n\u003cli\u003eThrust position measurement in critical rotating machinery\u003c\/li\u003e\n\u003cli\u003eMachinery protection and condition monitoring networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e 330180 (Proximitor Sensor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModification Code:\u003c\/strong\u003e 145004-47 (Recalibration to Specific Target Material)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e 3300 XL 5mm\/8mm 9m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModification Code\u003c\/td\u003e\n\u003ctd\u003e145004-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e10 to 90 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Zero\u003c\/td\u003e\n\u003ctd\u003e-3.0 Vdc @ 20 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Configuration\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5mm\/8mm 9m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure a dedicated electrical ground to prevent high-frequency noise from corrupting the sensor signal output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Ensure all field wiring cables are properly shielded with the drain wires terminated at the monitor rack side only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Adjustment:\u003c\/strong\u003e Calibrate the physical probe gap using a digital voltmeter to verify the electrical zero setting of -3.0 Vdc at a 20-mil distance before securing the probe.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572898667,"sku":"330180-X1-05 MOD：145004-47","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145004-47-proximitor-sensor-odczbzodjj0_9295702c-f8d3-4344-b88e-df2cd5d1db27.jpg?v=1765440870"},{"product_id":"bently-nevada-330881-br-05-060-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-05-060-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR (3300 XL 8 mm probe with INMETRO Brazilian approvals) and Option 05 (50 mm standoff adapter) specify this PROXPAC XL metric configuration — \u003cstrong\u003e330881-BR-05-060-00-02\u003c\/strong\u003e. This integrated proximity transducer assembly combines a 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor into a single, self-contained unit. By eliminating the extension cable between the probe and Proximitor, this design simplifies field wiring and reduces installation complexity.\u003c\/p\u003e\n\u003cp\u003eThis metric configuration is equipped with a 60 mm probe penetration length (Option 060), utilizes a 3\/4-14 NPT mounting thread (Option 02), and includes no conduit fittings (Option 00, supplied with two plugs and two washers). The housing is molded from glass-reinforced, UV-resistant polyphenylene sulfide (PPS) thermoplastic with conductive fibers, providing protection rating up to IP66 and Type 4X for severe industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Sensor Assembly:\u003c\/strong\u003e Integrates a 1-meter 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor within the same rugged housing to eliminate the need for an external extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINMETRO Approvals (Option BR):\u003c\/strong\u003e Furnishes a 3300 XL 8 mm probe compliant with Brazilian INMETRO hazardous area standards for explosive atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 mm Standoff Adapter (Option 05):\u003c\/strong\u003e Includes a 50 mm standoff adapter (B dimension) to adjust the housing height and clear machine obstructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e60 mm Penetration (Option 060):\u003c\/strong\u003e Configured with a 60 mm metric probe penetration sleeve length (C dimension) to accurately locate the probe tip relative to the target shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT Mounting (Option 02):\u003c\/strong\u003e Employs a 3\/4-14 NPT mounting thread option, which is standard for standoff installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFittings Configuration (Option 00):\u003c\/strong\u003e Supplied with no conduit fittings, containing two plugs and two washers for direct field-wire insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSevere-Environment Housing:\u003c\/strong\u003e Made from high-strength polyphenylene sulfide (PPS) thermoplastic to resist chemical attack, moisture, and impact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and axial position measurements on high-speed rotating machinery.\u003c\/li\u003e\n\u003cli\u003eMonitoring in hazardous petrochemical, oil and gas, and power generation environments requiring INMETRO certification.\u003c\/li\u003e\n\u003cli\u003eLocations with severe ambient conditions where separating Proximitor housings and using delicate extension cables is impractical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption \/ Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330881\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n\u003ctd\u003eBR\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazil) Hazardous Area Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e50 mm Standoff Adapter Length (B Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n\u003ctd\u003e060\u003c\/td\u003e\n\u003ctd\u003e60 mm Probe Penetration Length (C Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330881-BR-05-060-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm (3300 XL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Input\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-meter cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 meters \/ 1000 feet of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sleeve and Screws\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Isolation Material\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eIP66 and Type 4X rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/td\u003e\n\u003ctd\u003e-52 to +100 Celsius (-62 to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Probe Only)\u003c\/td\u003e\n\u003ctd\u003e-52 to +177 Celsius (-62 to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 to +105 Celsius (-62 to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor Output Signal (Negative Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVTX\u003c\/td\u003e\n\u003ctd\u003ePower Supply Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper alignment of the 3300 XL 8 mm probe tip with the shaft target surface (minimum target diameter 15.2 mm).\u003c\/li\u003e\n\u003cli\u003eSet the nominal gap to 1.27 mm (50 mils) corresponding to the midpoint of the linear range.\u003c\/li\u003e\n\u003cli\u003eApply standard torque values: 29.5 N-m (260 in-lb) for the retaining nut and 39.3 N-m (350 in-lb) for the probe sleeve locknut.\u003c\/li\u003e\n\u003cli\u003eAvoid routing field wiring near high-voltage lines or sources of heavy electromagnetic fields. Maximum field wiring length should not exceed 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003ePrevent moisture ingress into the PPS housing by sealing the conduit entries and keeping plugs securely tightened.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with European CE directives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e INMETRO (Brazil) Intrinsically Safe (Ex ia IIC T4\/T5 Ga) and Non-Incendive\/Increased Safety (Ex nA\/Ex ec IIC T4\/T5 Gc) via Option BR.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e IP66 and Type 4X rated housing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666574209387,"sku":"330881-BR-05-060-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-05-060-00-02-proxpac-xl-housing-djzzxu0vkex_216859ff-edc2-4f39-bdcd-55c05a2fbee0.jpg?v=1765440887"},{"product_id":"bently-nevada-330880-16-15-020-01-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-16-15-020-01-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 16 (3300 XL 8 mm probe, unapproved), Option 15 (1.5 in standoff adapter), and Option 020 (2.0 in probe penetration length) define the specific configuration of the \u003cstrong\u003e330880-16-15-020-01-02\u003c\/strong\u003e integrated \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis self-contained assembly integrates a 3300 XL 8 mm proximity probe and a 1-meter cable directly inside the probe sleeve, eliminating the need for separate extension cables and dedicated sensor housings. It utilizes an advanced polyphenylene sulfide (PPS) thermoplastic housing containing glass and conductive fibers to strengthen construction and dissipate electrostatic charges in severe industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 16 provides an integrated 3300 XL 8 mm proximity probe without hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 15 specifies an English standoff adapter length of 1.5 inches (38 mm) for precise spacing.\u003c\/li\u003e\n  \u003cli\u003eOption 020 establishes a probe penetration depth of 2.0 inches (51 mm) into the machine casing.\u003c\/li\u003e\n  \u003cli\u003eOption 01 supplies one 3\/4-14 NPT conduit fitting and two blanking plugs for robust cable sealing.\u003c\/li\u003e\n  \u003cli\u003eOption 02 designates a 3\/4-14 NPT mounting thread for securing the outer sleeve assembly.\u003c\/li\u003e\n  \u003cli\u003eIntegrated 3300 XL Proximitor sensor inside the housing cover eliminates the need for an external extension cable.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) thermoplastic construction offers IP66 and Type 4X environmental protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRotating machinery shaft vibration and axial position measurement\u003c\/li\u003e\n  \u003cli\u003eSimplified installations requiring integrated transducer and housing configurations\u003c\/li\u003e\n  \u003cli\u003eCritical industrial monitoring in power generation, chemical, and petrochemical plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n      \u003ctd\u003e330880-16-15-020-01-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, English\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe, non-approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option (B Dimension)\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n      \u003ctd\u003e1.5 inches (38 mm) standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option (C Dimension)\u003c\/td\u003e\n      \u003ctd\u003e020\u003c\/td\u003e\n      \u003ctd\u003e2.0 inches (51 mm) probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required if ordering standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003e330880-16-15-020-01-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer Type\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Proximity Transducer Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Input\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-meter cable length installed in probe sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Requirements\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers at 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range Boundary\u003c\/td\u003e\n      \u003ctd\u003eApproximately 0.25 mm to 2.3 mm (10 mils to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003eApproximately -1 Vdc to -17 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% over linear range from 0 degC to +45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 meters of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShaft Diameter Limits\u003c\/td\u003e\n      \u003ctd\u003eMinimum 50.8 mm (2.0 in), Recommended minimum 76.2 mm (3.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Housing Material\u003c\/td\u003e\n      \u003ctd\u003eGlass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Cable Type\u003c\/td\u003e\n      \u003ctd\u003e1-meter, 75 ohm triaxial, FEP insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Isolation Material\u003c\/td\u003e\n      \u003ctd\u003eExtra soft cellular silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnvironmental Protection Rating\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range (Probe)\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range (Housing\/Proximitor)\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eField Wiring Size\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax Field Wiring Length\u003c\/td\u003e\n      \u003ctd\u003e305 meters (1000 feet) between Proximitor sensor and monitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrounding: Ensure the grounding liner and retaining plate are properly installed in accordance with standard Bently Nevada practices.\u003c\/li\u003e\n  \u003cli\u003eShielding: Use 3-conductor shielded twisted cable with a drain wire (e.g., 18 AWG field wiring) to limit electrical noise.\u003c\/li\u003e\n  \u003cli\u003eTorque Specifications: Retaining Nut: 29.5 N-m (260 in-lb); Probe Sleeve Locknut: 39.3 N-m (350 in-lb).\u003c\/li\u003e\n  \u003cli\u003eConduit Connections: Seal threaded fittings option (3\/4-14 NPT) with sealant or Teflon tape to maintain environmental rating.\u003c\/li\u003e\n  \u003cli\u003eOperation voltage: Ensure supply voltage is between -23.5 Vdc and -26 Vdc with barriers to maintain full linear range capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eElectrical Classification: Complies with the European CE mark.\u003c\/li\u003e\n  \u003cli\u003eEMC Directives: EMC Directive 2014\/30\/EU (EN 61000-6-2 and EN 61000-6-4).\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive: RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003eMechanical\/Environmental: Type 4X and IP66 environments.\u003c\/li\u003e\n  \u003cli\u003eMaritime standards: ABS rules for conditions of classification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666578600299,"sku":"330880-16-15-020-01-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-16-15-020-01-02-proxpac-xl-proximity-transducer-gm1jeqfdedx_6c0bed14-e45f-4ccc-8b4f-589ec20d43cd.jpg?v=1765440936"},{"product_id":"bently-nevada-86497-01-02-02-00-cylinder-pressure-transducer","title":"Bently Nevada 86497-01-02-02-00 Cylinder Pressure Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e86497-01-02-02-00\u003c\/strong\u003e is a high-precision, industrial-grade \u003cstrong\u003ecylinder pressure transducer\u003c\/strong\u003e engineered specifically for dynamic pressure monitoring on reciprocating compressors and internal combustion engines. This specialized sensor captures high-frequency pressure changes inside active combustion or compression cylinders, transforming physical mechanical stress into an accurate electrical signal path for real-time thermodynamic diagnostics. The \u003cstrong\u003e86497-01-02-02-00\u003c\/strong\u003e interfaces seamlessly with advanced machinery diagnostic platforms, such as the Bently Nevada 3500\/77M Reciprocating Cylinder Pressure Monitor or System 1 software, to compute multi-point peak pressure variables, horse-power degradation indexes, and internal valve leakage symptoms.\u003c\/p\u003e\n\u003cp\u003eTo withstand the aggressive thermal shocks and chemical exposure typical of cylinder heads, the transducer assembly features a robust, corrosion-resistant stainless steel shell and an optimized piezoelectric sensing element. This specific option string dictates fixed operational boundaries, including standard physical thread patterns, a specialized top integrated connector setup, a specialized high-performance temperature insulation envelope, and default hazardous area approvals, ensuring safe, continuous structural asset protection.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecialized piezoelectric architecture capturing high-speed dynamic pressure waveforms without mechanical lag.\u003c\/li\u003e\n\u003cli\u003eRugged stainless steel housing configuration providing long-term resistance to high-pressure combustion byproducts.\u003c\/li\u003e\n\u003cli\u003eDirect compatibility with high-density reciprocating machinery protection racks and thermodynamic analyzer software.\u003c\/li\u003e\n\u003cli\u003eExcellent thermal compensation boundaries preventing calibration drift under sustained cyclic heat loads.\u003c\/li\u003e\n\u003cli\u003eLow-profile physical footprint designed to fit into standardized cylinder head indicator valve ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time dynamic pressure charting and valve condition monitoring on heavy-duty reciprocating process compressors.\u003c\/li\u003e\n\u003cli\u003eContinuous combustion balancing and peak pressure calculation across large-bore industrial diesel and natural gas engines.\u003c\/li\u003e\n\u003cli\u003eAdvanced asset diagnostic reporting and efficiency optimization tracking on balance-of-plant gas pipeline skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86497 (Cylinder Pressure Transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Code Assembly\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86497-01-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Option Suffix Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01 (Thread Size and Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-02 (Connector Layout Variant Suffix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-02 (Temperature \/ Performance Range Suffix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-00 (Hazardous Area Certifications Option - Standard\/None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86497-01-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiezoelectric Cylinder Pressure Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDynamic internal cylinder pressure \/ dynamic gas force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing Element Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial piezoelectric crystal configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-grade corrosion-resistant stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Transmission Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCharge or low-impedance voltage waveform proportional to pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size Option Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01 Option Specific Thread Geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Interface Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02 Option Specific Hermetic Connector Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Adaptation Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02 Option Specific Temperature Compensation Envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals Option Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00 Standard \/ Non-hazardous industrial placement rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Core Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRigid body structure designed for structural indicator valve mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard field pressure sensor assembly weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Point\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTop Integrated Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-insulation pin terminals for low-noise coaxial signal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Mounting Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThreaded mechanical interface for airtight indicator valve block attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRigid Port Mounting:\u003c\/strong\u003e Thread the sensor base directly onto the designated cylinder indicator valve port or specialized mounting adapter. Always torque the hex body to the exact engineering layout specifications to verify a leak-free mechanical seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Lead Routing:\u003c\/strong\u003e Connect a specialized low-noise coaxial cable loop to the top connector pins. Route this high-impedance signal run inside separate flexible metal conduit blocks away from high-current motor cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Mitigation Loops:\u003c\/strong\u003e Ensure that any integrated internal cooling passages or external protective shields are free from debris blockage to keep operational core temperatures inside the transducer sensor boundaries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicator Valve Settings:\u003c\/strong\u003e When performing temporary analytical tests, ensure the physical indicator valve is closed completely prior to mounting or unmounting the pressure transmitter body to prevent high-pressure gas bypass accidents.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666608779627,"sku":"86497-01-02-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-86497-01-02-02-00-interface-module-sy20htw12hz_f5f8226b-c119-41f6-8707-40dc8d913a9d.jpg?v=1765444112"},{"product_id":"bently-nevada-330780-12-00-3300-xl-11-mm-proximitor-sensor-1","title":"Bently Nevada 330780-12-00 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003eBently Nevada 330780-12-00\u003c\/strong\u003e 3300 XL Proximitor Sensor is a non-contact eddy current displacement transducer designed for precise vibration and position monitoring of rotating machinery. This specific configuration, indicated by option -12, provides a full-scale range of 0.040 inches (1.0 mm) and is optimized for use with Bently Nevada 3300 XL 11 mm proximity probes. It is suitable for applications requiring high accuracy and reliability in challenging industrial environments.\n\nThis Proximitor sensor is a key component of the 3300 XL Proximity Transducer System, which also includes an 11 mm proximity probe and an extension cable. The -00 option signifies no specific agency approvals, making it suitable for general-purpose industrial installations where hazardous area certifications are not required. The 3300 XL series is known for its improved performance over older designs, offering enhanced immunity to radio frequency interference (RFI) and transient protection.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact eddy current measurement principle for vibration and position.\u003c\/li\u003e\n\u003cli\u003eConfigured with Option -12 for 0.040 in (1.0 mm) full-scale range, compatible with 3300 XL 11 mm probes.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy and linearity for critical machinery monitoring.\u003c\/li\u003e\n\u003cli\u003eImproved RFI\/EMI immunity meeting CE mark requirements.\u003c\/li\u003e\n\u003cli\u003eRobust design for reliable operation in industrial environments.\u003c\/li\u003e\n\u003cli\u003eOffers high transient overvoltage protection.\u003c\/li\u003e\n\u003cli\u003eStandard configuration, designated by -00, for non-hazardous areas.\u003c\/li\u003e\n\u003cli\u003eTypically mounted in a panel, DIN rail, or custom enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAxial position (thrust) measurement on turbines, compressors, and pumps.\u003c\/li\u003e\n\u003cli\u003eRadial vibration monitoring on large rotating machinery shafts.\u003c\/li\u003e\n\u003cli\u003eDifferential expansion measurements.\u003c\/li\u003e\n\u003cli\u003eRod drop monitoring on reciprocating compressors.\u003c\/li\u003e\n\u003cli\u003eMonitoring shaft position relative to bearing clearances.\u003c\/li\u003e\n\u003cli\u003eMachinery protection and condition monitoring systems in power generation, oil and gas, petrochemical, and manufacturing industries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330780-12-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Proximitor Sensor\u003c\/td\u003e\n\u003ctd\u003e330780\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Full-Scale Range\/Probe Compatibility\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e0.040 in (1.0 mm) Full-Scale Range, for 11 mm Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Agency Approval (Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n\u003ctd\u003e330780-12-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Probes, 3300 XL Extension Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc to -30 Vdc (typically -24 Vdc nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum, typical (without alarm option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-2 Vdc to -22 Vdc (typical linear range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range (FSR)\u003c\/td\u003e\n\u003ctd\u003e0.040 in (1.0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-6% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e+\/-0.0001 in (+\/-0.0025 mm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 10 kHz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range (Operating)\u003c\/td\u003e\n\u003ctd\u003e-34 degC to +71 degC (-30 degF to +160 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range (Storage)\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel or DIN rail mount (with optional mounting clip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nProper installation is crucial for the optimal performance of the 3300 XL Proximitor Sensor. Ensure the sensor is securely mounted on a flat surface or DIN rail in a vibration-free area. All cables, including the probe and extension cables, must be routed away from sources of electrical noise and high-voltage lines to prevent interference. Grounding practices must adhere to Bently Nevada recommendations to ensure proper system performance and safety. The probe gap voltage should be set according to specific machinery requirements for accurate measurement and to utilize the full linear range of the Proximitor.\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\nThe 330780-12-00, specified with Option -00, does not include specific hazardous area agency approvals such as ATEX, IECEx, or CSA. It complies with general CE mark requirements for electromagnetic compatibility (EMC) and low voltage directive (LVD) for use in industrial environments.","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666609533291,"sku":"330901-00-90-10-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-90-10-01-05-3300-nsv-proximity-probes-0fsiu0gc41f_d5cb9fed-5442-47b8-bf87-ea592822f596.jpg?v=1765444120"},{"product_id":"bently-nevada-330880-ru-50-028-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-RU-50-028-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330880-RU-50-028-03-02\u003c\/strong\u003e: This English configuration of the Bently Nevada PROXPAC XL Proximity Transducer features Option RU for Russian EAC \/ TR CU hazardous area approvals, a 5.0-inch standoff adapter length (Option 50), and a 2.8-inch probe penetration depth (Option 028). Standardized as an integrated solution, it combines a 3300 XL 8 mm proximity probe and a Proximitor sensor inside a single Polyphenylene Sulfide (PPS) thermoplastic housing, eliminating the need for separate extension cables or junction boxes.\u003c\/p\u003e\n\u003cp\u003eEquipped with Option 03 fittings, the assembly includes one 3\/4-14 NPT fitting, a 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two plugs, mounting securely via a 3\/4-14 NPT thread (Option 02). This integrated transducer interfaces directly with 3300 XL monitoring system inputs over field wiring up to 305 meters, providing vibration and position measurements on rotating machinery where space, severe ambient conditions, or cable routing constraints restrict the use of discrete Proximitor housings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProbe and Approvals Option RU: Integrates a 3300 XL 8 mm proximity probe certified under Russian EAC \/ TR CU hazardous area safety standards.\u003c\/li\u003e\n  \u003cli\u003eStandoff Adapter Option 50: Configured with a 5.0-inch (127 mm) standoff adapter to adjust probe positioning relative to the machine casing.\u003c\/li\u003e\n  \u003cli\u003eProbe Penetration Option 028: Provides 2.8 inches (71 mm) of sleeve penetration depth into the machinery housing.\u003c\/li\u003e\n  \u003cli\u003eFittings Option 03: Supplied as a kit containing one 3\/4-14 NPT conduit fitting, one 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two blanking plugs.\u003c\/li\u003e\n  \u003cli\u003eMounting Thread Option 02: Outfitted with a 3\/4-14 NPT mounting thread, required for installations using a standoff adapter.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Transducer Design: Houses both the proximity probe and the Proximitor sensor in one self-contained assembly, removing the intermediate extension cable.\u003c\/li\u003e\n  \u003cli\u003eRobust PPS Enclosure: Constructed from ultraviolet-resistant, glass-reinforced polyphenylene sulfide (PPS) containing conductive fibers for electrostatic dissipation.\u003c\/li\u003e\n  \u003cli\u003eHigh Environmental Protection: Rated for NEMA Type 4X and IP66 environments to protect internal circuitry against moisture and dust ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and axial position measurements in heavy industrial rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eMonitoring installations with severe environment exposures where separate extension cables are prone to damage.\u003c\/li\u003e\n  \u003cli\u003eSteam and gas turbines, compressors, gearboxes, and large industrial pumps.\u003c\/li\u003e\n  \u003cli\u003eHazardous area machinery protection in regions requiring Russian EAC\/TR CU certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330880-RU-50-028-03-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (English)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals\u003c\/td\u003e\n      \u003ctd\u003eRU\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Russian EAC \/ GOST-R \/ TR CU hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 in (127 mm) standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration\u003c\/td\u003e\n      \u003ctd\u003e028\u003c\/td\u003e\n      \u003ctd\u003e2.8 in (71 mm) probe sleeve penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003e330880-RU-50-028-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Type\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe (1-metre cable length installed in sleeve)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Requirements\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) @ 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting at approx. 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003eApprox. -1 Vdc to -17 Vdc over the linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% (measured in 0.25 mm increments over 80 mil range, 0 degC to +45 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil) at 0 degC to 45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres \/ 1,000 feet of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Shaft Diameter\u003c\/td\u003e\n      \u003ctd\u003e76.2 mm (3.0 in) minimum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eUV-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRetaining Chain\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Sleeve \u0026amp; Retaining Screws\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGrounding Liner Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Isolation\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLid Label Material\u003c\/td\u003e\n      \u003ctd\u003eGloss Radiant White Polyester\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing \u0026amp; Proximitor Sensor Temp\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRetaining Nut Torque\u003c\/td\u003e\n      \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Sleeve Locknut Torque\u003c\/td\u003e\n      \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT \/ PWR\u003c\/td\u003e\n      \u003ctd\u003ePower Input\u003c\/td\u003e\n      \u003ctd\u003eNegative voltage supply connection (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon\u003c\/td\u003e\n      \u003ctd\u003eCircuit common and signal ground reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eSignal Output\u003c\/td\u003e\n      \u003ctd\u003eProportional dynamic voltage output (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Thread the outer sleeve assembly (Option 02) into the 3\/4-14 NPT machinery casing port, ensuring the standoff adapter (Option 50) is properly positioned and tightened to a torque of 39.3 N-m (350 in-lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Adjust the probe depth within the sleeve (C sleeve depth of 2.8 inches) until the static output voltage reads approximately -10 Vdc, indicating the recommended gap of 1.27 mm (50 mils) from the target shaft surface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit and Fittings:\u003c\/strong\u003e Route field wiring through the 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer (Option 03). Use suitable sealing methods on the conduit threads to keep moisture from travelling into the IP66-rated PPS housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure electrical continuity from the internal grounding liner of the housing to the machine casing to maintain shielding effectiveness.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRussian EAC \/ TR CU Hazardous Area Certifications (Option RU)\u003c\/li\u003e\n  \u003cli\u003eCE Mark Compliance (EMC Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eHousing Environmental Rating: NEMA Type 4X and IP66 (BASEEFA verified)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666610155883,"sku":"330880-RU-50-028-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-ru-50-028-03-02-thermal-conductivity-transmitter-nljbyqcwdtn_14bc3df8-58c1-40df-b1fb-da715fcda1f6.jpg?v=1765444129"},{"product_id":"bently-nevada-330850-50-00-3300-xl-25-mm-proximitor-sensor","title":"Bently Nevada 330850-50-00 3300 XL 25 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330850-50-00\u003c\/strong\u003e specifies a 3300 XL 25 mm Proximitor Sensor configured with a 5.0-metre system length, flat-surface panel mounting, and no agency approvals. This sensor functions as an analog signal conditioner within a 3300 XL 25 mm Proximity Transducer System, generating a continuous voltage output directly proportional to the distance between a paired 25 mm probe tip and a target material.\u003c\/p\u003e\n\u003cp\u003eUnlike DIN-mount configurations or variants built with intrinsic safety approvals, this unit is designed specifically for general-purpose, non-hazardous area panels. It supports large-target displacement monitoring applications, such as steam turbine thrust position and differential expansion. The system is designed to provide stable performance over extended temperature ranges when paired with 330851 probes and 330854 extension cables.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystem length of 5.0 metres (Option 50) is matched for calibration with standard five-meter probe and cable assemblies.\u003c\/li\u003e\n\u003cli\u003ePanel-mount mounting style (Option 50) comes complete with four 6-32 thread-forming mounting screws.\u003c\/li\u003e\n\u003cli\u003eNo agency approvals (Option 00) simplifies installation in standard general-purpose plant areas.\u003c\/li\u003e\n\u003cli\u003eSpringLoc terminal strips provide reliable, direct field wiring connections without requiring specialized crimping or landing tools.\u003c\/li\u003e\n\u003cli\u003eA380 aluminum housing is constructed to resist environmental corrosion and shield inner circuitry from electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eActive voltage regulation maintains high stability with less than 2 mV output drift per volt of supply input fluctuation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine thrust position monitoring\u003c\/li\u003e\n\u003cli\u003eDifferential expansion measurements on large utility turbine shafts\u003c\/li\u003e\n\u003cli\u003eReciprocating compressor rod-drop and displacement tracking\u003c\/li\u003e\n\u003cli\u003eLarge-diameter rotor mechanical position and vibration analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330850-50-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Total Length and Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330850-50-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n\u003ctd\u003eAccepts one 3300 XL 25 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e12.7 mm (500 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range Limits\u003c\/td\u003e\n\u003ctd\u003eBegins at approximately 0.63 mm (25 mils) up to 13.33 mm (525 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Scale Factor (ASF)\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils) at standard operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Supply Requirement\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Voltage\u003c\/td\u003e\n\u003ctd\u003eApproximately -1.5 Vdc to -11.5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 2.7 kHz (+0, -3 dB typical) with up to 305 metres of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Cable Support\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG); three-conductor shielded triad recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Distance\u003c\/td\u003e\n\u003ctd\u003e305 metres (1000 feet) to monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Limit\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Mass\u003c\/td\u003e\n\u003ctd\u003e255 g (9.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Designation\u003c\/th\u003e\n\u003cth\u003eDescription and Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoaxial Connector\u003c\/td\u003e\n\u003ctd\u003eInputs from the paired 3300 XL 25 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSystem Common \/ return path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eAnalog linear output voltage signal (-1.5 Vdc to -11.5 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003ePower supply input terminal (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the Proximitor on a flat metal panel or enclosure surface using the four supplied 6-32 thread-forming panel screws. Strip external field wire insulation to reveal conductors from 0.2 to 1.5 mm2 (16 to 24 AWG) and insert directly into the SpringLoc terminal blocks. Thread coaxial connections finger-tight to ensure robust contact, not exceeding the maximum recommended torque limit of 0.565 Nm (5 in-lb). Maintain environmental conditions within the operating temperature limits and protect coaxial connectors with self-fusing silicone tape if moisture exposure is possible.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666610450795,"sku":"330850-50-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330850-50-00-3300-xl-25-mm-proximitor-sensor-m4rs1uhxyrc_80cfc98f-bc8c-4e7a-85d7-c44ac2edcd83.jpg?v=1765444134"},{"product_id":"bently-nevada-aap1407030-00100-3300-xl-nsv-proximity-transducer-probe","title":"Bently Nevada AAP1407030-00100 3300 XL NSv Proximity Transducer Probe","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada AAP1407030-00100\u003c\/strong\u003e (interchangeable with factory cross-reference code \u003cstrong\u003e109548-01 P1407030-00100\u003c\/strong\u003e) is a specialized, non-contact eddy-current eddy-current proximity probe sensor belonging to the high-density \u003cstrong\u003e3300 XL NSv\u003c\/strong\u003e (Narrow Side View) Series. Engineered specifically for industrial fluid-film bearing machinery with extremely tight installation spaces, it delivers an optimized radiation footprint to mitigate counterbore, side-view, or rear-view physical restrictions. The probe operates by generating a high-frequency electromagnetic field that measures static gap voltage displacements and dynamic vibration frequencies, transferring accurate shaft position signals to a paired 3300 XL NSv Proximitor Sensor. It is primarily deployed on small-diameter rotating assemblies such as centrifugal air compressors, refrigeration chillers, and process gas turbo-compressors where conventional 5 mm or 8 mm sensor tips encounter structural interference or scale factor distortion from confined housing walls.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eTransducer Subsystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eEddy-current non-contact proximity probe sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eTarget Material Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eAISI 4140 steel (standard calibration target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eLinear Sensing Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eLinear Range Boundaries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0.25 mm to 1.75 mm (10 mils to 70 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eNominal Voltage Output Span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eApproximate linear voltage span from -1 VDC to -13 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over ambient limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eDeviation From Best Fit Straight Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eLess than ±0.06 mm (±2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eRecommended Operational Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eMinimum Shaft Target Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e30 mm (1.2 in) for standard radial X-Y configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eMinimum Flat Target Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e8.9 mm (0.35 in); 13 mm (0.5 in) recommended minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eProbe Tip Base Encapsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003ePolyphenylene sulfide (PPS) engineering thermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eProbe Case Material Housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eConnector Interface Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eGold-plated brass coaxial ClickLoc miniature connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eInternal Pressure Seal Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eIntegrated Viton O-ring for differential casing containment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e-34 °C to +177 °C (-30 °F to +351 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eStorage Temperature Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e-52 °C to +105 °C (-62 °F to +221 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eOperational Altitude Max Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eNet Item Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e0.10 kg (0.22 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale Factor Stability:\u003c\/strong\u003e For optimal eddy-current scaling, the target face must be flat and symmetric. If measuring on shaft diameters smaller than 30 mm (1.2 in) or flat profiles under 13 mm (0.5 in), reduction of the baseline gap voltage down towards the lower limit of the linear window may be necessary to correct for boundary attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSide-View Clearance:\u003c\/strong\u003e The specialized configuration allows this probe to withstand close proximity to adjacent metallic structures. However, cross-talk or field distortions can occur if the clear side-view path dips below the structural limits of the machine's counterbore geometry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterchangeability Rules:\u003c\/strong\u003e The probe must be paired exclusively with a 3300 XL NSv Proximitor Sensor and its corresponding 3300 NSv extension cable. Total electrical length configuration must be verified to prevent impedance mismatches across the channel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Terminal Torque:\u003c\/strong\u003e Hand-tighten the gold-plated coaxial connectors until a physical, tactile \"click\" is felt. Never apply pliers or wrenches to the miniature joints, as over-torqueing can fracture the internal center pin conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Protection Measures:\u003c\/strong\u003e Use the factory-supplied silicone self-fusing tape to wrap outer connector couplings exposed to moisture or particulate contamination. Avoid deploying silicone wrapping sections within the internal machinery casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBending Radius Demands:\u003c\/strong\u003e Maintain a minimum structural bending radius of 25.4 mm (1.0 in) for standard probe leads and armored extensions to prevent macro-bending fractures within the internal coax core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How does the AAP1407030-00100 model manage differential pressure inside process compressor casings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The sensor case features a dedicated internal Viton O-ring pressure configuration. This barrier acts as a mechanical seal to isolate differential process gases from migrating up the internal probe core and into outer terminal junction boxes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What is the main differentiator between this NSv series probe and standard Bently Nevada 8 mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The NSv series utilizes a highly narrowed electromagnetic sensing footprint. This allows it to accurate track radial vibration on miniature targets down to 8.9 mm in diameter where standard 8 mm probes would face extreme eddy-current side-loading errors from the machine walls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Is bench calibration or matched trimming mandatory when swapping out this sensor head?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: No. The product is manufactured to meet precise factory tolerance baselines, enabling complete structural interchangeability. Components can be swapped directly in the field without requiring bench recalibration or parameter scaling adjustments at the main machinery monitor rack.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666611302763,"sku":"AAP1407030-00100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-aap1407030-00100-3300-xl-nsv-proximity-probe-d2meg0vkew2_586c6fc7-077f-4ccd-8eff-2a34f90b719e.jpg?v=1765444143"}],"url":"https:\/\/www.plcprotech.com\/pl\/collections\/transducers.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}