{"title":"Weidmuller","description":"\u003cp\u003eWeidmuller is a leader in industrial connectivity and power electronics for smart cabinets. The brand architecture includes the modular u-remote I\/O system, \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/weidmuller-pro-power\"\u003ePRO Power\u003c\/a\u003e supplies, and \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/weidmuller-act20-interface\"\u003eACT20 signal conditioners\u003c\/a\u003e. Technical characteristics include high-density push-in terminal technology, low-power-consumption modules, and integrated web-based diagnostics. Functionally, Weidmuller hardware facilitates efficient wiring, signal isolation, and reliable power distribution. Their focus on the \"Smart Cabinet\" concept ensures that their components reduce installation time and enhance the data transparency required for modern Industry 4.0 automation systems.\u003c\/p\u003e","products":[{"product_id":"weidmuller-ie-sw-ip67-5m12-1504410000-unmanaged-ethernet-switch","title":"Weidmuller IE-SW-IP67-5M12 1504410000 Unmanaged Ethernet Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDecentralized network distribution in harsh industrial environments is simplified with the **Weidmuller IE-SW-IP67-5M12** (article number **1504410000**). This unmanaged Fast Ethernet switch features robust IP67 encapsulation, allowing direct field installation without the need for an additional protective control cabinet. Engineered to withstand demanding physical conditions, the device utilizes secure M12 connection technology to ensure reliable data transmission and vibration-resistant connections.\u003c\/p\u003e\n\n\u003cp\u003eOperating as a store-and-forward unmanaged switch, this unit automatically manages data packet forwarding and filtering. Its integrated electrical protections, including reverse polarity protection and overload current protection, safeguard connected field devices against electrical faults. The compact plastic housing is optimized for direct wall mounting, providing a space-saving and highly durable networking solution for modern industrial automation architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIP67 encapsulated housing provides complete protection against dust and temporary water immersion.\u003c\/li\u003e\n  \u003cli\u003eSupports Fast Ethernet transmission speeds for efficient field-level communication.\u003c\/li\u003e\n  \u003cli\u003eStore and Forward switching mechanism optimizes data traffic and minimizes packet errors.\u003c\/li\u003e\n  \u003cli\u003eIntegrated overload current protection rated at 1.1 A.\u003c\/li\u003e\n  \u003cli\u003eReverse polarity protection ensures safe electrical installation and startup.\u003c\/li\u003e\n  \u003cli\u003eFlexible power input options supporting both AC and DC voltage ranges.\u003c\/li\u003e\n  \u003cli\u003eVibration-resistant M12 connection interfaces designed for heavy-duty industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized field-level networking in automotive manufacturing and assembly lines.\u003c\/li\u003e\n  \u003cli\u003eFood and beverage processing facilities requiring washdown-compatible IP67 equipment.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, conveyor systems, and packaging machinery.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment plants requiring localized, moisture-resistant network nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIE-SW-IP67-5M12 (1504410000)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSwitch Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnmanaged\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSpeed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFast Ethernet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Switching\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStore and Forward\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24\/36 V DC, 24 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.12 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverload Current Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.1 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAvailable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Main Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePlastic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP67 encapsulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eType of Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWall mounting (screwed in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to 60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e125 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29.6 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e270 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eFunction \/ Coding\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1 x M12 socket\u003c\/td\u003e\n      \u003ctd\u003ePower Supply, A-coded, Pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 D-coded ports\u003c\/td\u003e\n      \u003ctd\u003eFast Ethernet Data Ports\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the device directly to a flat, rigid surface using the integrated wall-mounting screw holes. Ensure the mounting surface can support the weight of the switch and connected cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Use industrial-grade, shielded M12 cables to maintain the IP67 environmental seal and ensure electromagnetic compatibility (EMC). Hand-tighten all M12 connectors to the specified torque to prevent moisture ingress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24\/36 V DC or 24 V AC power source to the designated A-coded M12 power socket. Verify that the supply voltage matches the specified limits before energizing the system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Ensure the ambient operating temperature remains within the range of -25 degC to 60 degC. Avoid mounting the switch in locations with direct, continuous exposure to high-pressure steam jets.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102122860907,"sku":"IE-SW-IP67-5M12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-ip67-5m12-yowx3hqudz1.png?v=1776137761"},{"product_id":"weidmuller-1504250000-ie-sw-bl06-1tx-4poe-1sc-basic-line-unmanaged-poe-ethernet-switch","title":"Weidmuller 1504250000 IE-SW-BL06-1TX-4POE-1SC Basic Line Unmanaged PoE Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nIntegrating seamlessly into harsh industrial control architectures, the Weidmuller IE-SW-BL06-1TX-4POE-1SC unmanaged Ethernet switch facilitates robust data transmission and power delivery. This hardware variant, identified by part number 1504250000, features \u003cstrong\u003efour Power over Ethernet (PoE) ports\u003c\/strong\u003e, \u003cstrong\u003eone standard Fast Ethernet copper port\u003c\/strong\u003e, and \u003cstrong\u003eone SC-Duplex multimode fiber-optic port\u003c\/strong\u003e to support extended-distance communication up to 5 km.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eFour IEEE 802.3af\/at compliant PoE ports for simplified field device powering.\u003c\/li\u003e\n  \u003cli\u003eOne 100BaseFX multimode fiber port with SC-Duplex connector for noise-immune long-distance uplinks.\u003c\/li\u003e\n  \u003cli\u003eRedundant dual power inputs (12\/24\/48 V DC) to maximize system uptime.\u003c\/li\u003e\n  \u003cli\u003eIP30-rated aluminum housing designed for space-saving DIN-rail mounting.\u003c\/li\u003e\n  \u003cli\u003eStore-and-Forward switching architecture with a 2 K MAC address table.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eHeavy Industrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eIndustrial IP surveillance and security systems in manufacturing plants.\u003c\/li\u003e\n  \u003cli\u003eWLAN access point integration in warehouse environments.\u003c\/li\u003e\n  \u003cli\u003eDistributed control system (DCS) node networking in water\/wastewater facilities.\u003c\/li\u003e\n  \u003cli\u003eTraffic monitoring and outdoor telemetry stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1504250000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIE-SW-BL06-1TX-4POE-1SC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnmanaged PoE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTotal Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e6\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePoE Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4x RJ45 (10\/100BaseT(X))\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCopper Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x RJ45 (10\/100BaseT(X))\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFiber Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x SC-Duplex Multimode (100BaseFX)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTransmission Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5 km (typical)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTransmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100 Mbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12\/24\/48 V DC (Redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e64.56 A at 48 V DC (0.1 to 1 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x Removable 4-pin terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e768 kBit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-10 degC to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e50 mm x 115 mm x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e375 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 1.00g;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 1 (4-Pin Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1+ (Primary Power Input)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 2 (4-Pin Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1- (Primary Power Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 3 (4-Pin Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2+ (Redundant Power Input)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 4 (4-Pin Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2- (Redundant Power Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePorts 1 to 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10\/100BaseT(X) RJ45 with PoE Injector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePort 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10\/100BaseT(X) RJ45 Standard Copper Port\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePort 6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100BaseFX Multimode SC-Duplex Fiber Port\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe IE-SW-BL06 series serves as a direct drop-in replacement for older IE-SW-BL05 series configurations when PoE injection is required at the edge. Ensure that existing power supplies are rated for the total PoE budget (typically 15.4W per port for standard PoE) plus the switch's internal consumption.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen operating at the lower end of the input voltage range (12V or 24V DC), verify that the internal step-up converter can stably deliver the 48V DC required for PoE compliance to connected PDs (Powered Devices). In high-vibration environments, ensure the DIN-rail clip is securely locked and the 4-pin terminal block screws are torqued to 0.5 Nm to prevent intermittent power loss.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nAlways use shielded twisted-pair (STP) Cat5e or Cat6 cabling for the copper ports to mitigate electromagnetic interference (EMI) in high-voltage panels. The SC-Duplex fiber port must be cleaned with an approved optical fiber connector cleaner before insertion to prevent signal attenuation over the 5 km maximum run.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003e\n    CRITICAL WARNING: De-energize all power sources before attempting installation, wiring, or maintenance. Ensure the redundant power supply lines are completely isolated. Failure to follow these protocols can result in electrical shock, equipment damage, or unexpected system downtime.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the switch onto a standard TS 35 DIN rail, ensuring the top hook catches the rail first, then press down until the latch snaps into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the functional ground screw on the aluminum housing to the local protective earth (PE) system using a minimum 14 AWG wire.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the redundant power sources to the removable 4-pin terminal block, verifying correct polarity for V1 and V2 inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the terminal block into the switch socket and secure the retention screws.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the RJ45 copper cables and the SC-Duplex multimode fiber optic cable to their respective ports.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102123254123,"sku":"IE-SW-BL06-1TX-4POE-1SC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06-1tx-4poe-1sc-tvtmcarvlvx.png?v=1776137753"},{"product_id":"weidmuller-ie-sw-bl06t-1tx-4poe-1sc-1504260000-industrial-ethernet-poe-switch","title":"Weidmuller IE-SW-BL06T-1TX-4POE-1SC 1504260000 Industrial Ethernet PoE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eTo facilitate reliable Ethernet connectivity and Power over Ethernet (PoE) delivery in demanding industrial environments, the \u003cstrong\u003eWeidmuller IE-SW-BL06T-1TX-4POE-1SC\u003c\/strong\u003e (part number \u003cstrong\u003e1504260000\u003c\/strong\u003e) provides a robust, unmanaged network switching solution. This device features four Power over Ethernet Plus (PoE+) ports, one standard Fast Ethernet copper port, and one 100BaseFX multimode fiber port with an SC-Duplex connector. Engineered for reliable data transmission over long distances, the integrated fiber optic interface supports connections up to 5 km, making it ideal for distributed industrial networks.\u003c\/p\u003e\n\n\u003cp\u003eThe switch is housed in a rugged IP30-rated aluminum enclosure designed to withstand extreme temperatures and mechanical stress. With dual redundant power inputs and an extended operating temperature range, this \u003cstrong\u003eindustrial PoE switch\u003c\/strong\u003e ensures high network availability and continuous performance in critical infrastructure applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEquipped with 4 PoE+ ports compliant with IEEE 802.3at\/af standards for powering remote field devices.\u003c\/li\u003e\n  \u003cli\u003eIncludes 1 Fast Ethernet port (10\/100BaseT(X)) and 1 Multimode fiber port (100BaseFX) with an SC-Duplex connector.\u003c\/li\u003e\n  \u003cli\u003eSupports Store and Forward data switching architecture with a 1 K MAC address table size.\u003c\/li\u003e\n  \u003cli\u003eRedundant dual power inputs (24\/48 V DC) to ensure continuous operation in the event of a primary power failure.\u003c\/li\u003e\n  \u003cli\u003eHoused in a rugged IP30-rated aluminum enclosure suitable for harsh industrial environments.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range from -40 degC to 75 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation and process control systems.\u003c\/li\u003e\n  \u003cli\u003eIP-based video surveillance networks in remote or outdoor locations.\u003c\/li\u003e\n  \u003cli\u003ePower generation plants and water\/wastewater treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eTraffic monitoring and intelligent transportation systems (ITS).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmüller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIE-SW-BL06T-1TX-4POE-1SC (1504260000)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSwitch Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnmanaged PoE Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 Mbps (Fast Ethernet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePoE Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4x RJ45 (PoE+)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCopper Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1x RJ45 (10\/100BaseT(X))\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1x SC-Duplex (100BaseFX, Multimode)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 km (typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24\/48 V DC (Redundant inputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.5 A at 24 V DC, 2.6 A at 48 V DC (at full PoE+ load)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMAC Table Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePacket Buffer Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e512 kBit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e115 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e70 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e375 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector \/ Interface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRJ45 Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\/100BaseT(X) auto negotiation, Full\/Half duplex, Auto MDI\/MDI-X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSC-Duplex Port\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100BaseFX multimode fiber connection (5 km max distance)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 removable 4-pin terminal block for redundant power feeds\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely snap the device onto a standard 35 mm DIN rail. Ensure the DIN rail is properly grounded to the cabinet's earth ground.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the redundant power supplies to the 4-pin terminal block. Ensure correct polarity to prevent damage to the internal circuitry.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional ground terminal on the device to the local ground potential using a low-impedance conductor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain adequate clearance around the cooling vents of the IP30 aluminum housing to prevent thermal buildup in enclosed cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102123483499,"sku":"IE-SW-BL06T-1TX-4POE-1SC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06t-1tx-4poe-1sc-jh2slsoglea.png?v=1776137756"},{"product_id":"weidmuller-8965420000-act20x-2sdi-2hdo-s-valve-control-module","title":"Weidmuller 8965420000 ACT20X-2SDI-2HDO-S Valve Control Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFacilitating the safe control of intrinsically safe valves in hazardous environments, the \u003cstrong\u003eWeidmuller 8965420000\u003c\/strong\u003e (ACT20X-2SDI-2HDO-S) provides reliable signal isolation and switching. This dual-channel valve control module acts as an isolated barrier, translating control signals from the safe area into intrinsically safe outputs to drive solenoids, valves, and acoustic alarms located in Ex zones.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Channel Isolation:\u003c\/strong\u003e Supports two independent channels for space-saving, high-density cabinet layouts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Built-in alarm function detects and reports supply voltage loss and internal device errors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSoftware Configurable:\u003c\/strong\u003e Fully compatible with FDT\/DTM software for precise parameter adjustment and monitoring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Connections:\u003c\/strong\u003e Equipped with robust screw terminals to ensure vibration-resistant field wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Profile:\u003c\/strong\u003e 22.5 mm housing width optimizes DIN-rail space in control enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil \u0026amp; Gas Refineries:\u003c\/strong\u003e Actuation of intrinsically safe solenoid valves in hazardous processing zones.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChemical Processing:\u003c\/strong\u003e Safe signal transmission and isolation for chemical dosing and distribution systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePharmaceutical Manufacturing:\u003c\/strong\u003e Control of pneumatic and hydraulic valves in explosive dust or gas atmospheres.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater \u0026amp; Wastewater Treatment:\u003c\/strong\u003e Isolated valve control in wet wells and chemical treatment areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eValue \/ Rating\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8965420000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eACT20X-2SDI-2HDO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIntrinsically Safe Valve Control \/ Solenoid Driver\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNumber of Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 3.1 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNominal Switching Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 125 V AC \/ 110 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eContinuous Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStep Response Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConfiguration Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFDT\/DTM software\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.180 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.2 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe ACT20X-2SDI-2HDO-S is highly compatible with standard DCS and PLC digital output cards. When integrating this module into existing systems configured with older ACT20 series units, ensure that the FDT\/DTM frame application is updated to the latest device description files to prevent communication errors during setup.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen mounting multiple units side-by-side on a DIN rail, ensure the cabinet's thermal management system is active. Under maximum continuous current loads (0.5 A AC \/ 0.3 A DC), heat dissipation within high-density enclosures can rise. Maintain a minimum clearance or use active ventilation if the ambient temperature inside the panel consistently exceeds 45 degC.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways maintain strict physical separation between the blue intrinsically safe (Ex-i) field wiring and the non-intrinsically safe supply\/alarm connections. Mixing these routing paths violates hazardous area compliance. Use shielded cabling for the control signals to minimize high-frequency noise interference in high-transient environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #2d3748; font-size: 0.95rem;\"\u003eIsolate and de-energize all power sources before mounting, wiring, or configuring this module. Ensure the surrounding atmosphere is verified as non-hazardous (gas-free) before opening any protective enclosures or adjusting field connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eSnap the module securely onto a standard TS 35 DIN rail, ensuring the grounding spring makes solid contact with the rail.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConnect the 19.2 to 31.2 V DC power supply to the designated non-Ex power terminals.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eWire the intrinsically safe valve\/solenoid field devices to the blue Ex-i screw terminals, keeping the cables physically isolated from power lines.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConnect the alarm relay outputs to your supervisory PLC or safety system to monitor for voltage loss or device faults.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102123745643,"sku":"8965420000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965420000-xhmtf3wtpzc.png?v=1776137160"},{"product_id":"weidmuller-1469480000-pro-eco-120w-24v-5a-switch-mode-power-supply-unit","title":"Weidmuller 1469480000 PRO ECO 120W 24V 5A Switch-Mode Power Supply Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for reliable and space-saving power delivery in decentralized automation systems, the \u003cstrong\u003eWeidmuller 1469480000\u003c\/strong\u003e is a high-efficiency \u003cstrong\u003eswitch-mode power supply unit\u003c\/strong\u003e. Part of the robust PRO ECO series, this module delivers a regulated 24 V DC output at 5 A, providing a continuous 120 W of power. It features a wide-range input capable of accepting both AC and DC voltages, making it highly versatile for global industrial applications.\u003c\/p\u003e\n\n\u003cp\u003eThe unit is housed in a corrosion-resistant metal enclosure designed for TS 35 DIN rail mounting. It features an integrated potentiometer for output voltage adjustment, comprehensive diagnostic LEDs, and a floating status relay contact for remote monitoring. With built-in protection against overloads, short circuits, and over-temperature conditions, this power supply ensures high operational safety and system uptime in demanding environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh operational efficiency of 87% to minimize thermal losses inside control cabinets.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range supporting 85 to 264 V AC and 80 to 370 V DC.\u003c\/li\u003e\n  \u003cli\u003eAdjustable output voltage from 22 to 28 V DC via a front-panel potentiometer.\u003c\/li\u003e\n  \u003cli\u003eTricolor LED diagnostics for real-time status indication (Green, Yellow, Red).\u003c\/li\u003e\n  \u003cli\u003eIntegrated floating relay contact for remote monitoring of output status.\u003c\/li\u003e\n  \u003cli\u003eRobust, corrosion-resistant metal housing with a compact 40 mm width.\u003c\/li\u003e\n  \u003cli\u003eSupport for parallel connection of up to 5 units to increase power capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation and control cabinet assembly.\u003c\/li\u003e\n  \u003cli\u003eMachine building and precision factory automation.\u003c\/li\u003e\n  \u003cli\u003eProcess engineering and water treatment facilities.\u003c\/li\u003e\n  \u003cli\u003ePower distribution networks and wind energy systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1469480000 (PRO ECO 120W 24V 5A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range (AC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85...264 V AC (derating at 100 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range (DC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80...370 V DC (derating at 120 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e47...63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.26 A @ 230 V AC \/ 2.24 A @ 110 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.39 A @ 370 V DC \/ 1.16 A @ 120 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003emax. 40 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC +\/- 1 %\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e22...28 V DC (adjustable via potentiometer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 A @ 55 degC, 3.75 A @ 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResidual Ripple \/ Breaking Spikes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eless than 50 mVPP @ 24 V DC, IN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Failure Bridging Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003egreater than 80 ms @ 230 V AC \/ greater than 20 ms @ 115 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e87%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Loss (Idling \/ Nominal Load)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 W \/ 15 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGreen LED (Uout \u0026gt; 21.6 V DC), Yellow LED (Iout \u0026gt; 90% nominal), Red LED (overload, overtemperature, short-circuit, Uout \u0026lt; 20.4 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFloating Contact \/ Relay\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes (max. 30 V DC \/ 1 A), active when Uout \u0026gt; 21.6 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConductor Cross-Section (Rigid)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5...6 mm² (AWG 26...12)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConductor Cross-Section (Flexible, Input)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5...2.5 mm² (max)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e40 mm x 125 mm x 100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e675 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eTerminal Specification \/ Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection for L, N, and PE (0.5 to 6 mm² rigid)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection for +24 V DC and -24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStatus Relay\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFloating contact (NO), max. 30 V DC \/ 1 A for remote diagnostics\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap vertically onto a standard TS 35 DIN rail. Ensure the internal cooling vents are positioned at the top and bottom.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain adequate clearance above and below the module to facilitate natural convection cooling and prevent thermal derating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriate wire cross-sections (up to 6 mm² for rigid conductors) and ensure screw terminals are tightened to the recommended torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the PE (Protective Earth) terminal securely to the system ground to ensure proper electromagnetic compatibility (EMC) and electrical safety.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102123811179,"sku":"PRO ECO 120W 24V 5A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469480000-41foci3xh3m.png?v=1776137074"},{"product_id":"weidmuller-1504230000-ie-sw-bl06-4poe-2st-basic-line-unmanaged-poe-switch","title":"Weidmuller 1504230000 IE-SW-BL06-4POE-2ST Basic Line Unmanaged PoE Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for demanding industrial Ethernet networks, the Weidmuller IE-SW-BL06-4POE-2ST (part number 1504230000) provides reliable Power over Ethernet (PoE+) distribution and fiber-optic connectivity in a compact, unmanaged form factor. This switch integrates \u003cstrong\u003efour 10\/100BaseT(X) PoE+ ports\u003c\/strong\u003e and \u003cstrong\u003etwo 100BaseFX multimode fiber ports\u003c\/strong\u003e with ST-Duplex connectors, making it an ideal choice for extending network segments up to 5 km while delivering power to field devices.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSupports IEEE 802.3at\/af standards, delivering up to 30 watts per PoE port.\u003c\/li\u003e\n  \u003cli\u003eDual redundant 24\/48 V DC power inputs to maximize network uptime.\u003c\/li\u003e\n  \u003cli\u003eRugged IP30-rated aluminum housing designed for space-constrained control cabinets.\u003c\/li\u003e\n  \u003cli\u003eStore-and-Forward switching architecture with a 1 K MAC address table.\u003c\/li\u003e\n  \u003cli\u003eIntegrated broadcast storm protection to maintain network stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial automation and control system networks.\u003c\/li\u003e\n  \u003cli\u003eIP surveillance and security systems in harsh outdoor environments.\u003c\/li\u003e\n  \u003cli\u003ePower utility and substation monitoring requiring optical isolation.\u003c\/li\u003e\n  \u003cli\u003eWater\/wastewater treatment facilities and manufacturing plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eDescription\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-BL06-4POE-2ST\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504230000\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e6-port unmanaged PoE switch, 4x PoE+ RJ45, 2x ST Multimode Fiber\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-BL06-4POE-2ST \/ 1504230000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnmanaged PoE+\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100 Mbps (Fast Ethernet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransceiver Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMultimode\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eST-Duplex\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 km (typical)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eVoltage Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24\/48 V DC (Redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5.5 A at 24 V DC, 2.6 A at 48 V DC (at full PoE+ load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e512 kBit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 mm x 115 mm x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e375 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSignal Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eDescription\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV1+\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary Power Input (+24 \/ +48 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV1-\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary Power Input Ground (GND)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV2+\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRedundant Power Input (+24 \/ +48 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV2-\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRedundant Power Input Ground (GND)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IE-SW-BL06-4POE-2ST is part of Weidmuller's Basic Line industrial switch series. If single-mode fiber infrastructure is deployed on-site, the SC-connector or single-mode variants of this series should be utilized to match the optical budget and cable characteristics. It is fully backward compatible with standard IEEE 802.3af (15.4W) devices, automatically scaling power delivery based on connected PD (Powered Device) negotiation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen operating at the maximum ambient temperature limit of 60 degC with all four PoE+ ports delivering full 30W loads, ensure a minimum of 20mm lateral clearance from adjacent heat-generating DIN-rail devices. Enclosed control cabinets must have active ventilation to prevent localized thermal buildup. Note that current draw increases significantly at 24 V DC (up to 5.5 A) compared to 48 V DC (2.6 A); size your power supply and wiring gauges accordingly to prevent voltage drops.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways clean the ST-Duplex fiber connectors with an approved optical cleaning tool before insertion. Even minor dust contamination can cause severe signal attenuation over the 5 km optical path. Ensure the IP30 aluminum housing is grounded using the integrated grounding screw to a low-impedance earth ground to protect internal circuitry from electrostatic discharge (ESD) and electromagnetic interference (EMI).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e \u003cspan style=\"color: #9b2c2c;\"\u003eDe-energize all power sources before connecting or disconnecting the 4-pin terminal block. Do not hot-plug the power connector under load. Verify that the supply voltage matches the specified 24\/48 V DC limits to avoid catastrophic damage to the switch.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSnap the switch securely onto the TS35 DIN rail, ensuring the top hook engages first before pressing the bottom latch into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect a dedicated grounding wire from the ground screw on the switch chassis to the local protective earth ground point.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the 4-pin removable terminal block with your primary (V1) and optional redundant (V2) power lines, then secure the terminal screws.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the RJ45 Ethernet cables into ports 1 through 4 and connect the ST-Duplex fiber cables to the optical ports.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102124040555,"sku":"IE-SW-BL06-4POE-2ST","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06-4poe-2st-lldaxz03rsf.png?v=1776137755"},{"product_id":"weidmuller-8965480000-act20x-2hti-2sao-s-act20x-series-temperature-transducer","title":"Weidmuller 8965480000 ACT20X-2HTI-2SAO-S ACT20X Series Temperature Transducer","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Processing temperature sensor signals from hazardous areas is the primary function of the \u003cstrong\u003eWeidmuller 8965480000 ACT20X-2HTI-2SAO-S\u003c\/strong\u003e, a highly reliable 2-channel intrinsically safe temperature transducer. This module isolates, converts, and transmits temperature signals from RTD and thermocouple sensors located in Ex Zone 0, 1, or 2 to the safe area. It features dual-channel density in a compact 22.5 mm housing, providing active or passive 4-20 mA current outputs compatible with standard PLC and DCS analog input cards.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Channel Isolation:\u003c\/strong\u003e Two independent, galvanically isolated channels maximize channel density on the DIN rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntrinsically Safe Inputs:\u003c\/strong\u003e Certified for direct connection to temperature sensors in Zone 0, 1, and 2 hazardous locations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Sensor Support:\u003c\/strong\u003e Configurable for Pt100, Pt500, Pt1000, Ni100 RTDs, and thermocouple types J, K, T, E, R, S, B, N, L, and U.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e Integrated alarm functions detect line interruption, short circuits, supply voltage failure, and internal device errors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFDT\/DTM Configuration:\u003c\/strong\u003e Easily parameterized using standard FDT\/DTM software via the front-facing service interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChemical Processing:\u003c\/strong\u003e Monitoring reactor vessel temperatures in explosive atmospheres.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil \u0026amp; Gas:\u003c\/strong\u003e Temperature measurement on offshore platforms, pipelines, and storage tank farms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Exhaust gas and bearing temperature monitoring in hazardous turbine enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater \u0026amp; Wastewater:\u003c\/strong\u003e Digester and chemical treatment plant temperature telemetry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8965480000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eACT20X-2HTI-2SAO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNumber of Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e≤ 1.4 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInput Types\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRTD (Pt100, Pt500, Pt1000, Ni100), Thermocouples (J, K, T, E, R, S, B, N, L, U)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOutput Signal\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4 to 20 mA (Active or Passive)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStep Response Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e≤ 400 ms (current input), ≤ 1 s (temperature input)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNominal Switching Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e≤ 125 V AC \/ 110 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eContinuous Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e≤ 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eClamping Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.5 mm² to 2.5 mm²\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFlammability Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV-0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eHumidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e119.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.180 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.200 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eTerminal Block\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eTerminal Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style='padding: 0.75rem; rowspan=\"2\";'\u003eHazardous Area (Input)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e11, 12, 13, 14\u003c\/td\u003e\n        \u003ctd style='padding: style=\"padding: 0.75rem;\"'\u003eChannel 1: RTD (2, 3, or 4-wire) \/ Thermocouple Input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e21, 22, 23, 24\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eChannel 2: RTD (2, 3, or 4-wire) \/ Thermocouple Input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style='padding: 0.75rem; rowspan=\"3\";'\u003eSafe Area (Output \u0026amp; Power)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e41, 42\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eChannel 1: 4 to 20 mA Analog Output (Active\/Passive)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e51, 52\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eChannel 2: 4 to 20 mA Analog Output (Active\/Passive)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e31 (+), 32 (-)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDevice Power Supply (19.2 to 31.2 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The ACT20X-2HTI-2SAO-S is the dual-channel variant within Weidmuller's ACT20X intrinsically safe signal converter family. If only a single channel is required, the ACT20X-HTI-SAO-S (single-channel version) can be utilized to reduce hardware costs. Configuration profiles created in the FDT\/DTM \"WI-Manager\" software are fully interchangeable between single and dual-channel models, simplifying commissioning when scaling up system architectures.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When mounting multiple ACT20X modules side-by-side on a DIN rail, thermal management is critical. Although the device is rated up to +60 degC, dense installations with continuous 24V DC supply can lead to localized heat build-up. It is recommended to maintain a 5 mm ventilation gap between adjacent modules if the ambient cabinet temperature regularly exceeds 50 degC. Additionally, ensure the loop resistance of the passive output configuration does not exceed the maximum load limits specified for your DCS analog input card.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  For thermocouple inputs, always ensure that the cold junction compensation (CJC) is correctly configured in the DTM software. If using internal CJC, ensure the terminal block connections are tight and shielded from direct drafts or external heat sources, which can induce measurement drift. For RTD inputs, utilizing a 3-wire or 4-wire connection configuration is highly recommended to automatically compensate for lead wire resistance over long field runs.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all power sources before mounting, wiring, or configuring the device. Ensure strict separation between intrinsically safe (Ex i) field wiring and non-intrinsically safe safe-area wiring in compliance with EN\/IEC 60079-14. Failure to maintain physical separation can compromise the explosion protection barrier.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the ACT20X module vertically onto a standard TS 35 DIN rail, ensuring the locking foot securely clicks into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the hazardous area temperature sensor wiring to the blue Ex-input terminals (11-14 and 21-24) using shielded, twisted-pair cables.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the safe-area analog outputs (41-42 and 51-52) and the 24 V DC power supply (31-32) to the black terminals.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the configuration interface to a PC running Weidmuller WI-Manager (FDT\/DTM) to set the sensor type, range, and alarm thresholds.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102124106091,"sku":"8965480000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965480000-3nxsduvsaa5.png?v=1776137168"},{"product_id":"weidmuller-ie-sw-vl05mt-5tx-valueline-managed-industrial-ethernet-switch","title":"Weidmuller IE-SW-VL05MT-5TX ValueLine Managed Industrial Ethernet Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for demanding industrial networking environments, the \u003cstrong\u003eWeidmuller IE-SW-VL05MT-5TX\u003c\/strong\u003e (article number \u003cstrong\u003e1504310000\u003c\/strong\u003e) is a managed Fast Ethernet switch engineered to provide reliable data transmission under harsh operational conditions. This 5-port device supports managed switch functionalities, utilizing a store-and-forward data switching architecture to optimize traffic flow and minimize packet loss across local automation networks.\u003c\/p\u003e\n\n\u003cp\u003eHoused in a rugged IP30-rated metal enclosure, this switch is built to withstand extreme temperatures ranging from -40 degC to 75 degC. It features redundant power inputs to ensure continuous network uptime even in the event of a primary power supply failure. Its compact form factor and support for both DIN rail and panel mounting make it highly adaptable for integration into standard control cabinets.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 Fast Ethernet ports supporting high-speed local data communication.\u003c\/li\u003e\n  \u003cli\u003eManaged switch capabilities for enhanced network configuration and diagnostics.\u003c\/li\u003e\n  \u003cli\u003eStore-and-forward data switching technology to ensure packet integrity.\u003c\/li\u003e\n  \u003cli\u003eRedundant power inputs (12\/24\/48 V DC) to maximize system availability.\u003c\/li\u003e\n  \u003cli\u003eRugged IP30 metal housing protecting internal components from dust and debris.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range from -40 degC to 75 degC for extreme environments.\u003c\/li\u003e\n  \u003cli\u003eFlexible installation options including DIN rail and panel mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation and control system networks.\u003c\/li\u003e\n  \u003cli\u003ePower generation and electrical substation monitoring.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility communications.\u003c\/li\u003e\n  \u003cli\u003eOil and gas processing and distribution pipelines.\u003c\/li\u003e\n  \u003cli\u003eWind, solar, and renewable energy monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIE-SW-VL05MT-5TX (1504310000)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSwitch Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eManaged\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSpeed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFast Ethernet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Switching\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStore and Forward\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMAC Table Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePacket Buffer Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 Mbit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12\/24\/48 V DC (2 redundant inputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 removable 6-pin terminal block\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMetal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e53.6 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e135 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e105 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e650 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRJ45 Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 x 10\/100BaseT(X) auto-negotiation ports\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 removable 6-pin terminal block for redundant power inputs and relay output\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap the device securely onto a standard 35mm DIN rail. For panel mounting, utilize the optional panel mounting kit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional ground contact on the terminal block to a low-impedance earth ground to ensure adequate protection against electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use the removable 6-pin terminal block to connect the redundant 12\/24\/48 V DC power sources. Verify correct wiring polarity before energizing the system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure sufficient clearance around the IP30 metal housing to facilitate natural convection cooling, particularly when operating near the maximum temperature limit of 75 degC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102124171627,"sku":"IE-SW-VL05MT-5TX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-vl05mt-5tx-z4tealztwhj.png?v=1776137766"},{"product_id":"weidmuller-1504270000-ie-sw-bl06-1tx-4poe-1st-basicline-unmanaged-poe-fast-ethernet-switch","title":"Weidmuller 1504270000 IE-SW-BL06-1TX-4POE-1ST BasicLine Unmanaged PoE Fast Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo facilitate robust Ethernet connectivity and power delivery in demanding industrial environments, the Weidmuller 1504270000 (model IE-SW-BL06-1TX-4POE-1ST) provides a reliable, unmanaged networking solution. This device integrates \u003cstrong\u003efour IEEE 802.3af\/at compliant Power-over-Ethernet (PoE+) ports\u003c\/strong\u003e, one standard \u003cstrong\u003e10\/100BaseT(X) RJ45 port\u003c\/strong\u003e, and one \u003cstrong\u003e100BaseFX multimode fiber port\u003c\/strong\u003e utilizing an \u003cstrong\u003eST-Duplex connector\u003c\/strong\u003e. Housed in a rugged \u003cstrong\u003eIP30 aluminum enclosure\u003c\/strong\u003e, this switch is designed to withstand harsh electromagnetic interference and extreme thermal variations typical of factory automation and process control networks.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eEquipped with 4 PoE+ ports delivering up to 30 Watts per port for high-draw field devices.\u003c\/li\u003e\n  \u003cli\u003eIntegrated ST-Duplex multimode fiber transceiver supporting transmission distances up to 5 km.\u003c\/li\u003e\n  \u003cli\u003eRedundant dual power inputs (24\/48 V DC) with wide-range voltage tolerance.\u003c\/li\u003e\n  \u003cli\u003eStore-and-Forward data switching architecture with a 1 K MAC address table size.\u003c\/li\u003e\n  \u003cli\u003ePassive cooling design housed in a compact, space-saving IP30 aluminum chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial IP surveillance systems requiring remote camera power delivery.\u003c\/li\u003e\n  \u003cli\u003eWastewater treatment facilities with distributed field instrumentation.\u003c\/li\u003e\n  \u003cli\u003ePower substations and wind energy monitoring networks.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor control systems in automotive manufacturing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1504270000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIE-SW-BL06-1TX-4POE-1ST\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnmanaged PoE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTransmission Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFast Ethernet (10\/100 Mbps)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x 10\/100BaseT(X)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePoE Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4x 10\/100BaseT(X) PoE+ (IEEE 802.3at\/af)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFiber Optic Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x 100BaseFX Multimode (ST-Duplex connector)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTransmission Distance (Typ.)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5 km\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e512 kBit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24\/48 V DC (2 redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5.5 A at 24 V DC, 2.6 A at 48 V DC (at full PoE+ load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 removable 4-pin terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e50 mm x 115 mm x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e375 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal Pin \/ Interface\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 1 (Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1+ (Primary Power Input +24 \/ +48 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 2 (Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1- (Primary Power Input Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 3 (Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2+ (Redundant Power Input +24 \/ +48 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 4 (Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2- (Redundant Power Input Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePorts 1 to 4 (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10\/100BaseT(X) Fast Ethernet with IEEE 802.3at PoE+ Output\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePort 5 (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10\/100BaseT(X) Standard Fast Ethernet Uplink\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePort 6 (ST-Duplex)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100BaseFX Multimode Fiber Optic Port (TX\/RX)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IE-SW-BL06-1TX-4POE-1ST replaces standard non-PoE variants where field devices require power over the data line. Note that the ST-Duplex fiber interface requires matching multimode fiber cabling (50\/125 or 62.5\/125 micrometers) and is not compatible with single-mode (SC\/LC) systems without an active media converter.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen operating at 24 V DC, the internal step-up converter generates significant heat under full 120W PoE+ load. Ensure at least 20mm of lateral clearance on the DIN rail to prevent thermal throttling or adjacent module degradation. Do not exceed the 5.5 A input threshold at 24 V DC.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways terminate the functional ground screw on the chassis directly to the local low-impedance DIN rail ground. Use shielded twisted pair (STP) Cat5e or Cat6 cabling for the RJ45 ports to mitigate high-frequency electromagnetic noise in motor control centers.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eEnsure all power sources (V1 and V2) are completely de-energized before attempting to wire the 4-pin terminal block. Verify that the power supply output matches the 24\/48 V DC rating of the switch. Failure to isolate power can result in electrical shock, equipment damage, or arc flash hazards.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the switch securely onto the TS35 DIN rail, ensuring the top latch engages first before snapping the bottom clip into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the functional earth ground wire to the designated grounding screw on the aluminum housing to ensure proper EMI shielding.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the redundant power inputs to the removable 4-pin terminal block, securing the screws to a torque of 0.5 Nm.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eInsert the ST-Duplex fiber connectors, ensuring correct TX\/RX crossover alignment with the remote transceiver.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the RJ45 Ethernet and PoE field cables, verifying that the port LEDs illuminate to indicate active link and power delivery.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102124564843,"sku":"IE-SW-BL06-1TX-4POE-1ST","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06-1tx-4poe-1st-fdwi0xsprq0.png?v=1776137754"},{"product_id":"weidmuller-1469470000-proeco-pro-eco-72w-24v-3a-switch-mode-power-supply-unit","title":"Weidmuller 1469470000 PROeco PRO ECO 72W 24V 3A Switch-Mode Power Supply Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for space-restricted control cabinets, the Weidmuller \u003cstrong\u003e1469470000\u003c\/strong\u003e (\u003cstrong\u003ePRO ECO 72W 24V 3A\u003c\/strong\u003e) provides highly efficient and reliable power conversion in a compact 34 mm housing. This industrial-grade \u003cstrong\u003eswitch-mode power supply\u003c\/strong\u003e delivers a regulated 24 V DC output with up to 87% efficiency, minimizing thermal dissipation and optimizing energy consumption. Equipped with comprehensive protection circuits, it handles wide-range AC and DC inputs, making it globally compatible with diverse automation architectures and power grids.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh efficiency rating of 87% reduces heat generation inside enclosures.\u003c\/li\u003e\n  \u003cli\u003eWide-range input capability supporting 85 to 264 V AC and 80 to 370 V DC.\u003c\/li\u003e\n  \u003cli\u003eAdjustable output voltage from 22 to 28 V DC via a front-facing potentiometer.\u003c\/li\u003e\n  \u003cli\u003eTri-color LED diagnostic indicators for real-time status monitoring (voltage, current, and faults).\u003c\/li\u003e\n  \u003cli\u003eIntegrated protection against short-circuits, overloads, and overtemperature conditions.\u003c\/li\u003e\n  \u003cli\u003eSupport for parallel connection of up to 5 units to increase capacity or build redundant systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation and control panel distribution.\u003c\/li\u003e\n  \u003cli\u003eMachine building and manufacturing process control.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility systems.\u003c\/li\u003e\n  \u003cli\u003eWind, solar, and conventional power generation control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1469470000 \/ PRO ECO 72W 24V 3A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROeco\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range (AC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85...264 V AC (derating at 100 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range (DC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80...370 V DC (derating at 120 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e47...63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.55 A @ 230 V AC \/ 1.04 A @ 110 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.22 A @ 370 V DC \/ 0.68 A @ 120 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 40 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC ± 1 %\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e22...28 V DC (adjustable via potentiometer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 A @ 55 degC \/ 2.25 A @ 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e72 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e87%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Loss (Idling \/ Nominal Load)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 W \/ 9.5 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGreen LED (Uout \u0026gt; 21.6 V DC), Yellow LED (Iout \u0026gt; 90% nominal), Red LED (overload, overtemp, short-circuit, Uout \u0026lt; 20.4 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTS 35 DIN rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC...70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC...85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePermissible Air Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5%...95% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e34 mm x 125 mm x 100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e557 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the device vertically on a TS 35 DIN rail to ensure optimal natural convection cooling.\u003c\/li\u003e\n  \u003cli\u003eMaintain adequate clearance above and below the unit to prevent heat accumulation.\u003c\/li\u003e\n  \u003cli\u003eEnsure the protective earth (PE) terminal is securely connected to the system ground before powering the unit.\u003c\/li\u003e\n  \u003cli\u003eUse appropriately rated wire cross-sections for the screw terminals to handle nominal input and output currents.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102125023595,"sku":"PRO ECO 72W 24V 3A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469470000-4emg4pepos4.png?v=1776137073"},{"product_id":"weidmuller-8965360000-act20x-hdi-sdo-s-isolating-switch-amplifier","title":"Weidmuller 8965360000 ACT20X-HDI-SDO-S Isolating Switch Amplifier","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing digital signals from hazardous areas requires robust galvanic isolation, which the \u003cstrong\u003eWeidmuller 8965360000 ACT20X-HDI-SDO-S\u003c\/strong\u003e delivers as a high-performance, 2-channel isolating switch amplifier. This device safely transmits switching states from NAMUR sensors or mechanical contacts located in Zone 0, 1, or 2 hazardous areas to the safe area control system, providing complete electrical separation and signal conditioning in a compact form factor.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDual-channel intrinsically safe input for NAMUR sensors or dry mechanical contacts.\u003c\/li\u003e\n  \u003cli\u003eGalvanic 4-way isolation between input, output, power supply, and status output.\u003c\/li\u003e\n  \u003cli\u003eIntegrated line fault detection (LFD) for continuous wire-break and short-circuit monitoring.\u003c\/li\u003e\n  \u003cli\u003eFDT\/DTM software-configurable parameters for custom application tuning and diagnostics.\u003c\/li\u003e\n  \u003cli\u003eRelay outputs (1 changeover contact per channel) for robust load switching.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm DIN-rail housing to optimize cabinet space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIntrinsically safe signal isolation in chemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eOil and gas pipeline monitoring systems requiring Zone 0\/1 sensor deployment.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility telemetry and pump control.\u003c\/li\u003e\n  \u003cli\u003eHazardous area valve position feedback and limit switch integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eArticle Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8965360000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eACT20X-HDI-SDO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNumber of Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNAMUR sensor (DIN EN 60947-5-6) or mechanical switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOutput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRelay (1 changeover contact per channel)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNominal Switching Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e250 V AC \/ 30 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e\u0026lt;= 1.1 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eIsolation Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.6 kV AC (input \/ output \/ power)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eConnection Technology\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eClamping Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.5 to 2.5 mm2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eFlammability Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUL 94 V-0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.170 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTerminal Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e11 \/ 12\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eChannel 1 Input (NAMUR Sensor \/ Mechanical Switch)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e21 \/ 22\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eChannel 2 Input (NAMUR Sensor \/ Mechanical Switch)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e51 \/ 52 \/ 53\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eChannel 1 Relay Output (NC \/ COM \/ NO)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e61 \/ 62 \/ 63\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eChannel 2 Relay Output (NC \/ COM \/ NO)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e91 \/ 92\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePower Supply (19.2 to 31.2 V DC: + \/ -)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe ACT20X-HDI-SDO-S is part of Weidmuller's premium ACT20X signal converter family. It serves as a direct replacement or upgrade path for legacy ACT20 series modules. When migrating from older systems, verify that your configuration files are updated in the FDT\/DTM frame to match the specific firmware revision of the 8965360000 module.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing standard mechanical switches instead of NAMUR sensors, the Line Fault Detection (LFD) circuit must be configured correctly. If LFD is enabled without external resistors, the module will interpret an open switch as a wire break and a closed switch as a short circuit. To prevent false diagnostics, either disable LFD via the DTM software or wire a resistor network (typically 1k Ohm in series and 10k Ohm in parallel) directly at the switch contacts.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eConfiguration is performed using the Weidmuller WI-Manager software via the front-panel service jack. Ensure the CBX200 USB interface cable is used for connection. For field wiring, maintain a minimum physical separation of 50 mm between the intrinsically safe (Ex i) blue terminals on the left side and the non-intrinsically safe terminals on the right side to comply with international hazardous area installation standards.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDe-energize all power sources before mounting, wiring, or configuring the device. Failure to isolate power can result in electrical shock or spark generation in hazardous areas, compromising explosion protection safety.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSnap the module vertically onto a standard TS 35 DIN rail, ensuring the metal grounding spring on the back makes secure contact with the rail.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the intrinsically safe field sensors to the blue terminals (11\/12 and 21\/22), ensuring proper cable routing away from power lines.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the relay outputs and the 24 V DC power supply to the black terminals on the opposite side of the module.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the configuration interface to set the desired input\/output logic and LFD parameters using the FDT\/DTM software before commissioning.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102125252971,"sku":"8965360000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965360000-ghbv2hkqdq2.png?v=1776137152"},{"product_id":"weidmuller-1504290000-ie-sw-bl06t-1tx-4poe-1st-basic-line-unmanaged-poe-switch","title":"Weidmuller 1504290000 IE-SW-BL06T-1TX-4POE-1ST Basic Line Unmanaged PoE Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nFacilitating robust data transmission and power delivery in demanding industrial environments, the Weidmuller 1504290000 (IE-SW-BL06T-1TX-4POE-1ST) functions as a high-performance, unmanaged Fast Ethernet PoE switch. This unit integrates four Power over Ethernet ports, one standard copper port, and one multimode fiber port with an ST-Duplex connector to bridge long-distance network segments up to 5 kilometers. Housed in a rugged IP30 aluminum enclosure, it is engineered to withstand extreme thermal variations and electrical noise common in industrial automation architectures.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnmanaged Plug-and-Play:\u003c\/strong\u003e Operates immediately upon connection without complex software configuration or IP assignment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Power over Ethernet:\u003c\/strong\u003e Features 4 dedicated PoE ports to power compatible field devices directly over Ethernet cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptical Fiber Uplink:\u003c\/strong\u003e Equipped with 1 multimode ST-Duplex port supporting transmission distances up to 5 km.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Inputs:\u003c\/strong\u003e Dual 12\/24\/48 V DC inputs ensure continuous network uptime in the event of a primary power supply failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Enclosure:\u003c\/strong\u003e Compact IP30-rated aluminum housing designed for space-constrained DIN-rail or panel mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial manufacturing and assembly line control networks.\u003c\/li\u003e\n  \u003cli\u003eIP-based video surveillance and security systems in harsh outdoor environments.\u003c\/li\u003e\n  \u003cli\u003ePower over Ethernet device integration including sensors, RFID readers, and wireless access points.\u003c\/li\u003e\n  \u003cli\u003eLong-distance fiber optic uplinks in municipal infrastructure and water treatment facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504290000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-BL06T-1TX-4POE-1ST\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnmanaged PoE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100 Mbps (Fast Ethernet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransceiver Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMultimode\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eST-Duplex\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Distance (Typical)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 km\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e12\/24\/48 V DC (2 redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e64.56 A at 48 V DC (0.1 to 1 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e768 kBit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eData Switching Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStore and Forward\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 75 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHumidity Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 mm x 114 mm x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e375 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eConnector \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eType\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePorts 1 to 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRJ45\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10\/100BaseT(X) Fast Ethernet with PoE Power Delivery\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePort 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRJ45\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStandard 10\/100BaseT(X) Fast Ethernet Copper Port\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePort 6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eST-Duplex\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100BaseFX Multimode Fiber Optic Port (up to 5 km)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4-pin terminal block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRemovable connector for redundant DC power supply inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe IE-SW-BL06T series serves as a direct drop-in replacement for older Weidmuller Basic Line unmanaged switches when migrating to PoE-enabled field architectures. Because this is an unmanaged Layer 2 device, it does not require firmware configuration or software updates, ensuring seamless compatibility across all standard Ethernet protocols and industrial automation networks.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen operating at full PoE capacity, ensure the upstream power supply is rated to handle the combined power budget of all connected PDs (Powered Devices) plus the switch's internal consumption. In enclosed control cabinets with high ambient temperatures, maintain a minimum of 20 mm clearance on both sides to facilitate natural convection and prevent thermal shutdown.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nAlways utilize high-quality shielded twisted-pair (STP) cabling for the copper RJ45 ports to minimize electromagnetic interference (EMI) in high-voltage environments. Ensure the functional ground terminal on the 4-pin removable block is connected directly to a low-impedance earth ground to protect the internal transceiver circuitry from transient voltage surges.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all power sources before attempting installation, wiring, or maintenance. Failure to isolate power can result in severe electrical shock, equipment damage, or unexpected system operation. Verify that the input voltage matches the device specifications before powering on.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the switch securely onto a standard TS 35 DIN rail, ensuring the locking mechanism snaps firmly into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the functional ground terminal on the removable 4-pin block to the local protective earth system.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the redundant DC power supplies to the terminal block, verifying correct polarity (V+\/V-) before inserting the block into the switch.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the RJ45 network cables into ports 1 through 5, and connect the ST-Duplex fiber optic cable to port 6.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102125384043,"sku":"IE-SW-BL06T-1TX-4POE-1ST","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06t-1tx-4poe-1st-vhn1dpxxrhl.png?v=1776137757"},{"product_id":"weidmuller-8965370000-act20x-2hdi-2sdo-rno-s-isolating-switch-amplifiers","title":"Weidmuller 8965370000 ACT20X-2HDI-2SDO-RNO-S Isolating Switch Amplifiers","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for intrinsic safety applications, the \u003cstrong\u003eWeidmuller 8965370000\u003c\/strong\u003e functions as a highly reliable \u003cstrong\u003eisolating switch amplifier\u003c\/strong\u003e to transmit digital signals from hazardous areas (Zone 0, 1, 2) to safe areas. This 2-channel module is engineered to process signals from NAMUR sensors or mechanical contacts located in explosive atmospheres, providing complete galvanic isolation between the input, output, power supply, and alarm contacts.\u003c\/p\u003e\n\n\u003cp\u003eThe ACT20X-2HDI-2SDO-RNO-S features integrated line fault detection (LFD) to monitor the input circuits for wire breaks or short circuits. In the event of a fault, the device triggers an alarm relay, ensuring rapid diagnostics and minimizing system downtime. Configuration is easily managed via standard FDT\/DTM software, allowing precise customization of operational parameters to match specific process requirements.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-channel signal isolation and transmission from Ex to non-Ex zones.\u003c\/li\u003e\n  \u003cli\u003eIntrinsically safe input circuits compatible with NAMUR sensors and mechanical switches.\u003c\/li\u003e\n  \u003cli\u003eTwo normally open (NO) relay outputs for reliable signal switching.\u003c\/li\u003e\n  \u003cli\u003eComprehensive line fault detection (LFD) for short-circuit and wire-break monitoring.\u003c\/li\u003e\n  \u003cli\u003eFDT\/DTM software configuration for flexible parameter adjustment.\u003c\/li\u003e\n  \u003cli\u003eComplete galvanic isolation between input, output, power supply, and alarm contacts.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm DIN-rail mountable housing to optimize cabinet space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eOil and gas extraction, refining, and distribution facilities.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment automation.\u003c\/li\u003e\n  \u003cli\u003eHazardous area digital signal isolation (Zone 0, 1, 2, and Class I Div 1\/2).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8965370000 (ACT20X-2HDI-2SDO-RNO-S)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIsolating Switch Amplifier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNAMUR sensor (DIN EN 60947-5-6) or switch contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNAMUR Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 V DC \/ 8 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRelay (1 NO contact per channel)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Switching Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e125 V AC \/ 110 V DC (safe area)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤ 1.9 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFDT\/DTM software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 95% (no condensation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.190 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Pin\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInputs (Hazardous Area)\u003c\/td\u003e\n      \u003ctd\u003eChannel 1 \u0026amp; Channel 2 NAMUR \/ Switch Contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutputs (Safe Area)\u003c\/td\u003e\n      \u003ctd\u003eChannel 1 \u0026amp; Channel 2 Relay NO Contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (+ \/ -)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAlarm Output\u003c\/td\u003e\n      \u003ctd\u003eFault signaling relay contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount vertically on a standard TS 35 DIN rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Ensure strict physical separation between intrinsically safe (Ex i) input wiring and non-intrinsically safe output\/power wiring. Maintain a minimum distance of 50 mm between the terminal groups.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the DIN rail to the local functional earth ground to ensure proper shielding and noise immunity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Provide adequate clearance above and below the module to prevent heat buildup inside the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eATEX\u003c\/li\u003e\n  \u003cli\u003eIECEx\u003c\/li\u003e\n  \u003cli\u003eUL Class I, Division 2 \/ Zone 2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102125744491,"sku":"8965370000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965370000-k0avku5nd1b.png?v=1776137154"},{"product_id":"weidmuller-1504470000-ie-gwt-mb-2tx-1rs232-485-modbus-tcp-rtu-gateway","title":"Weidmuller 1504470000 IE-GWT-MB-2TX-1RS232\/485 Modbus TCP\/RTU Gateway","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nFacilitating seamless protocol translation between serial Modbus RTU\/ASCII and Ethernet-based Modbus TCP networks, the \u003cstrong\u003eWeidmuller 1504470000\u003c\/strong\u003e (model \u003cstrong\u003eIE-GWT-MB-2TX-1RS232\/485\u003c\/strong\u003e) serves as an industrial-grade communication gateway designed for high-reliability automation environments. This device bridges legacy serial field devices with modern Ethernet control architectures, ensuring low-latency data transmission and robust network integration.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eDual Ethernet ports (2TX) allowing for daisy-chain network topologies and simplified cabling.\u003c\/li\u003e\n  \u003cli\u003eSoftware-selectable serial interface supporting RS-232, RS-422, and RS-485 configurations.\u003c\/li\u003e\n  \u003cli\u003eRedundant 24 V DC power inputs to maximize system uptime and operational resilience.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Serial Redirection and Priority Control for optimized traffic management.\u003c\/li\u003e\n  \u003cli\u003eCompact, space-saving IP30 plastic housing designed for standard DIN rail mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eSubstation automation and power monitoring network integration.\u003c\/li\u003e\n  \u003cli\u003eConnecting legacy serial PLCs and RTUs to modern SCADA host systems.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility remote telemetry.\u003c\/li\u003e\n  \u003cli\u003eFactory automation and machine-to-machine (M2M) communication bridging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504470000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-GWT-MB-2TX-1RS232\/485\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2x RJ45 (10\/100BaseT(X))\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSerial Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1x RS-232\/425\/485 (DB9 male or terminal block options)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 V DC (Redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 removable 7-pole terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 75 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAmbient Relative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePlastic\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDIN rail\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e29 mm x 124.5 mm x 89.2 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e190 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterface \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e7-Pole Terminal Block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRedundant Power Input 1 (V1+, V1-), Redundant Power Input 2 (V2+, V2-), Functional Earth (FE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRJ45 Ports (1 \u0026amp; 2)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10\/100BaseT(X) Ethernet interfaces with auto MDI\/MDI-X crossover detection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSerial Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRS-232 (TxD, RxD, GND) \/ RS-485 (Data+, Data-, GND) software-configurable pins\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe IE-GWT-MB-2TX-1RS232\/485 is backward compatible with standard Modbus RTU devices operating over RS-485 2-wire networks. When replacing older single-port serial servers, the dual Ethernet ports on this model eliminate the need for an external switch in simple line topologies, reducing overall panel hardware costs.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nIn high-density electrical cabinets, ensure adequate clearance around the IP30 plastic housing to maintain natural convection cooling. While rated up to 75 degC, operating continuously at extreme temperatures without proper ventilation can accelerate component aging. Always verify that the Modbus TCP client timeout settings are configured to accommodate the serial bus latency, especially when polling multiple daisy-chained RTU slaves.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen wiring the RS-485 network, always install a 120-ohm termination resistor at both physical ends of the communication line to prevent signal reflections. Ensure the Functional Earth (FE) terminal on the 7-pole block is connected directly to a low-impedance ground plane to safeguard the internal transceiver circuits from transient voltage spikes and electromagnetic interference.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Disconnect all power sources before attempting installation, wiring, or removal of the gateway. Failure to de-energize the system can result in electrical shock, equipment damage, or unexpected control system behavior.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the gateway onto a standard TS 35 DIN rail, ensuring the locking mechanism snaps firmly into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the Functional Earth (FE) terminal to the local ground system to ensure proper noise immunity.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the redundant 24 V DC power supplies to the removable 7-pole terminal block, verifying correct polarity before energizing.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the RJ45 Ethernet cables and the serial interface lines, securing all physical connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102126203243,"sku":"IE-GWT-MB-2TX-1RS232\/485","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-gwt-mb-2tx-1rs232485-ub3zkh2nhar.png?v=1776137750"},{"product_id":"weidmuller-1504320000-ie-sw-bl05-1gt-4gtpoe-gigabit-ethernet-poe-switch","title":"Weidmuller 1504320000 IE-SW-BL05-1GT-4GTPOE Gigabit Ethernet PoE Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Designed to integrate high-speed copper connections into demanding automation networks, the \u003cstrong\u003eWeidmuller 1504320000\u003c\/strong\u003e (Type \u003cstrong\u003eIE-SW-BL05-1GT-4GTPOE\u003c\/strong\u003e) serves as a robust 5-port Gigabit Ethernet unmanaged switch equipped with Power over Ethernet (PoE) capabilities. This industrial-grade hardware provides reliable data switching and power delivery over a single cable, simplifying field deployments for IP cameras, wireless access points, and remote I\/O stations.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Connectivity:\u003c\/strong\u003e Equipped with 4 Gigabit PoE+ ports and 1 standard Gigabit uplink port for high-bandwidth data backhaul.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJumbo Frame Support:\u003c\/strong\u003e Handles packets up to 10 KB to optimize transmission efficiency in high-throughput applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Inputs:\u003c\/strong\u003e Dual 12\/24\/48 V DC inputs ensure continuous network uptime even if one power source fails.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Housing:\u003c\/strong\u003e Housed in a compact, IP30-rated aluminum enclosure designed for space-constrained DIN rail installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStore-and-Forward Architecture:\u003c\/strong\u003e Optimizes data integrity by verifying checksums before forwarding packets across the network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial IP surveillance and security systems requiring reliable PoE+ power.\u003c\/li\u003e\n  \u003cli\u003eFactory automation networks with distributed I\/O, PLCs, and HMI panels.\u003c\/li\u003e\n  \u003cli\u003eSCADA infrastructure in power distribution, water treatment, and traffic control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003ePart Number\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eType Designation\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eDescription\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1504320000\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIE-SW-BL05-1GT-4GTPOE\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e5-port Gigabit Unmanaged PoE Switch (4x PoE+, 1x Uplink)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIE-SW-BL05-1GT-4GTPOE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1504320000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnmanaged PoE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePort Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4x 10\/100\/1000BaseT(X) PoE+, 1x 10\/100\/1000BaseT(X)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eData Switching\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStore and Forward\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1,024 Kbit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eJumbo Frame Support\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUp to 10 KB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12\/24\/48 V DC (2 redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e17.4 A at 24 V DC (0.1 to 1 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 removable 2-pole terminal blocks\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDIN rail\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 degC to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e29 mm x 135 mm x 105 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e360 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eInterface \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eConnection Type\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePorts 1 to 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRJ45 (Gigabit)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e10\/100\/1000BaseT(X) with IEEE 802.3af\/at PoE+ power sourcing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePort 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRJ45 (Gigabit)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStandard 10\/100\/1000BaseT(X) uplink connection (non-PoE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePWR1 \/ PWR2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2-pole removable terminal block\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRedundant DC power supply inputs (12\/24\/48 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The IE-SW-BL05-1GT-4GTPOE is a direct upgrade for older 10\/100 Mbps unmanaged PoE switches, providing the necessary bandwidth for modern high-definition IP cameras and high-speed industrial field devices. Ensure that connected PDs (Powered Devices) conform strictly to IEEE 802.3af\/at standards to prevent power negotiation faults.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When operating at the upper thermal limit of 60 degC, maintain at least 20 mm of lateral clearance from adjacent heat-producing components on the DIN rail. High PoE loads generate significant internal thermal dissipation; operating at maximum PoE budget inside unventilated, sealed enclosures can lead to thermal throttling or premature component aging.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Always utilize shielded twisted pair (STP) Cat5e or Cat6 cabling in high-noise industrial environments to mitigate electromagnetic interference (EMI). Ensure the switch housing is properly grounded via the functional earth contact on the DIN rail mounting clip to protect sensitive internal circuitry from electrostatic discharge (ESD) and line surges.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all power sources before mounting, wiring, or servicing the switch. Ensure the input voltage matches the specified limits (12\/24\/48 V DC) to prevent permanent hardware damage or electrical hazards.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eSnap the switch securely onto a standard TS 35 DIN rail, ensuring the metal ground spring on the back makes solid contact with the rail.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the redundant DC power supplies to the 2-pole removable terminal blocks, verifying correct polarity before applying power.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eInsert the RJ45 network cables into the appropriate ports. Ports 1 through 4 will automatically negotiate and deliver PoE power to compatible devices.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102126530923,"sku":"IE-SW-BL05-1GT-4GTPOE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl05-1gt-4gtpoe-v4bllne054a.png?v=1776137748"},{"product_id":"weidmuller-8965390000-act20x-act20x-2hdi-2sdo-s-isolating-switch-amplifiers","title":"Weidmuller 8965390000 ACT20X ACT20X-2HDI-2SDO-S Isolating Switch Amplifiers","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntrinsically safe signal transmission in hazardous industrial environments is managed efficiently by the \u003cstrong\u003e8965390000\u003c\/strong\u003e isolating switch amplifier. This dual-channel module processes digital signals from Ex Zone 0 areas, providing reliable galvanic isolation and signal conditioning for NAMUR sensors and mechanical contacts. By isolating the input and output circuits, the device ensures safe operation of control systems in the safe zone.\u003c\/p\u003e\n\n\u003cp\u003eEngineered with advanced diagnostics, the \u003cstrong\u003eACT20X-2HDI-2SDO-S\u003c\/strong\u003e supports comprehensive alarm monitoring to identify fault conditions instantly. The module is configured via standardized FDT\/DTM software, allowing precise parameter adjustment and simple integration into modern distributed control systems (DCS) and PLC architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-channel digital input (2HDI) and digital output (2SDO) configuration.\u003c\/li\u003e\n  \u003cli\u003eIntrinsically safe isolation barrier designed for Zone 0, 1, and 2 applications.\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic alarms for line interruption, input short circuits, supply voltage loss, and internal device errors.\u003c\/li\u003e\n  \u003cli\u003eFDT\/DTM software-based configuration for flexible parameter setup.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm DIN-rail housing to optimize cabinet space.\u003c\/li\u003e\n  \u003cli\u003eRobust screw connection terminals for secure wiring in high-vibration environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas extraction and refining facilities.\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eWastewater treatment plants with hazardous gas environments.\u003c\/li\u003e\n  \u003cli\u003ePower generation and fuel storage monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003e8965390000 \/ ACT20X-2HDI-2SDO-S\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Series\u003c\/strong\u003e\n      \u003ctd\u003eACT20X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Type\u003c\/strong\u003e\n      \u003ctd\u003eIsolating Switch Amplifier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\n      \u003ctd\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Consumption\u003c\/strong\u003e\n      \u003ctd\u003e\u0026lt;= 1.5 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNAMUR Supply\u003c\/strong\u003e\n      \u003ctd\u003e8 V DC \/ 8 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNominal Switching Voltage\u003c\/strong\u003e\n      \u003ctd\u003e\u0026lt;= 125 V AC \/ 110 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eContinuous Current\u003c\/strong\u003e\n      \u003ctd\u003e\u0026lt;= 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConfiguration\u003c\/strong\u003e\n      \u003ctd\u003eFDT\/DTM software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eType of Connection\u003c\/strong\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProtection Degree\u003c\/strong\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\n      \u003ctd\u003e0 to 95% (no condensation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\n      \u003ctd\u003e11.72 cm x 2.25 cm x 11.36 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.180 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the device vertically or horizontally on a standard TS 35 DIN rail.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum clearance around the module to ensure proper natural convection cooling.\u003c\/li\u003e\n  \u003cli\u003eEnsure strict physical separation between intrinsically safe (Ex) and non-intrinsically safe wiring paths.\u003c\/li\u003e\n  \u003cli\u003eVerify that the DIN rail is properly grounded to the functional earth of the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102126858603,"sku":"8965390000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965390000-ueqygkegbud.png?v=1776137156"},{"product_id":"weidmuller-1504420000-ie-sw-ip67t-5m12-unmanaged-industrial-ethernet-switch","title":"Weidmuller 1504420000 IE-SW-IP67T-5M12 Unmanaged Industrial Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for decentralized, cabinet-free installation in demanding environments, the \u003cstrong\u003eWeidmuller 1504420000\u003c\/strong\u003e (model \u003cstrong\u003eIE-SW-IP67T-5M12\u003c\/strong\u003e) provides reliable Fast Ethernet distribution directly on machinery. This unmanaged switch features a fully encapsulated plastic housing with an \u003cstrong\u003eIP67 ingress protection rating\u003c\/strong\u003e, eliminating the need for protective junction boxes and reducing field wiring complexity.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eFive 10\/100BaseT(X) ports utilizing robust M12 D-coded female connectors.\u003c\/li\u003e\n  \u003cli\u003eIP67-rated encapsulated plastic housing resistant to dust, moisture, and temporary water immersion.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range from -40 degC to 75 degC for extreme thermal environments.\u003c\/li\u003e\n  \u003cli\u003eFlexible power supply options supporting 24\/36 V DC or 24 V AC via an A-coded M12 connector.\u003c\/li\u003e\n  \u003cli\u003eIntegrated overload current protection (1.1 A) and reverse polarity protection.\u003c\/li\u003e\n  \u003cli\u003eStore-and-Forward switching architecture with wire-speed forwarding rates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eHeavy Industrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly:\u003c\/strong\u003e Direct mounting on robotic arms and welding cells where space is limited.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFood \u0026amp; Beverage:\u003c\/strong\u003e Washdown areas requiring dust-tight and water-resistant networking hardware.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Decentralized conveyor control and sorting systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutdoor Infrastructure:\u003c\/strong\u003e Exposed field installations subject to wide temperature fluctuations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504420000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-IP67T-5M12\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnmanaged\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 x M12 D-coded (Female, 4-pin)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 x M12 A-coded (Male, 5-pin)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24\/36 V DC, 24 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.12 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOverload Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.1 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eReverse Polarity Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAvailable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePlastic (Encapsulated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP67\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWall mounting (screwed in)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 degC to 75 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e60 mm x 125 mm x 29.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e270 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector Specification\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin Assignment \/ Function\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEthernet Ports (1 to 5)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eM12 Female, D-coded, 4-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePin 1: TD+, Pin 2: RD+, Pin 3: TD-, Pin 4: RD-\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Input Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eM12 Male, A-coded, 5-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePin 1: V+, Pin 2: V+, Pin 3: V-, Pin 4: V-, Pin 5: FE (Functional Earth)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem; font-weight: bold;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IE-SW-IP67T-5M12 serves as a direct upgrade path for older IP30 or IP20 DIN-rail switches when migrating to decentralized, cabinet-free field architectures. Ensure that all mating patch cables are industrial-grade, double-shielded Cat5e or higher with molded M12 D-coded connectors to maintain signal integrity in high-EMI environments.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem; font-weight: bold;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhile the encapsulated plastic housing is highly resilient to moisture, it is not rated for continuous high-pressure washdowns (IP69K). For washdown zones, mount the switch in a semi-protected location or shield it from direct high-pressure spray. Unused M12 ports must be sealed with IP67-rated protective caps to prevent moisture ingress and internal pin corrosion.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem; font-weight: bold;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use a calibrated torque wrench to tighten the M12 connectors to the manufacturer-recommended 0.6 Nm. Under-tightening compromises the IP67 seal, while over-tightening can strip the plastic threads or deform the internal O-ring. Ensure Pin 5 (FE) of the power connector is connected to a low-impedance local ground point to minimize noise coupling.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eDisconnect all power sources before mounting or servicing the switch. Failure to de-energize the system prior to connection or disconnection of M12 cables can result in electrical arcing, damage to the internal transceiver components, or personal injury.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003ePosition the switch on a flat, rigid mounting surface. Secure the unit using the integrated mounting holes with appropriate M4 screws.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the functional earth (FE) wire to Pin 5 of the power cable, ensuring a low-resistance path to the machine ground.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eAlign and plug in the M12 A-coded power cable. Hand-tighten, then torque to exactly 0.6 Nm.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the M12 D-coded Ethernet cables to the active ports. Seal all unused ports with IP67 protective caps.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102127055211,"sku":"IE-SW-IP67T-5M12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-ip67t-5m12-pppbuq0fw5r.png?v=1776137762"},{"product_id":"weidmuller-1504370000-ie-sw-vl05m-3tx-2st-managed-industrial-ethernet-switch","title":"Weidmuller 1504370000 IE-SW-VL05M-3TX-2ST Managed Industrial Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Managing deterministic data distribution across harsh manufacturing environments is the primary function of the \u003cstrong\u003eWeidmuller 1504370000 IE-SW-VL05M-3TX-2ST\u003c\/strong\u003e managed industrial Ethernet switch. This high-performance network node integrates copper and fiber interfaces to bridge long-distance field segments while maintaining robust electromagnetic immunity. Encased in a rugged metal housing, it provides reliable \u003cstrong\u003eStore and Forward\u003c\/strong\u003e data switching for time-critical automation architectures.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManaged Network Control:\u003c\/strong\u003e Comprehensive configuration options for traffic prioritization, VLAN segmentation, and ring redundancy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHybrid Port Configuration:\u003c\/strong\u003e Features 3 RJ45 Fast Ethernet ports and 2 Multimode fiber ports with ST-Duplex connectors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Optical Range:\u003c\/strong\u003e Supports reliable fiber optic transmission distances up to 5 km.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Redundancy:\u003c\/strong\u003e Dual redundant 12\/24\/48 V DC power inputs ensure continuous operation during primary supply failures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Build:\u003c\/strong\u003e IP30-rated metal chassis designed to withstand high mechanical vibration and thermal stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eHeavy Industrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWind Power Generation:\u003c\/strong\u003e Linking nacelle control systems to ground-level SCADA networks over optical fiber.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and Wastewater Treatment:\u003c\/strong\u003e Connecting distributed PLC nodes across large physical footprints without electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil and Gas Processing:\u003c\/strong\u003e Safe deployment in control cabinets requiring robust thermal management and redundant power feeds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Automation:\u003c\/strong\u003e High-speed machine-to-machine (M2M) communication on standard DIN rail assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-VL05M-3TX-2ST\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504370000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eManaged\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100 Mbps (Fast Ethernet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3x 10\/100BaseT(X)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFiber Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2x Multimode (ST-Duplex)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTypical Fiber Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 km\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 Mbit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e12 \/ 24 \/ 48 V DC (Redundant Inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnection Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1x Removable 6-pin terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMetal (IP30 Protection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-10 degC to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e53.6 mm x 135 mm x 105 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e650 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTerminal Block Pin Assignment\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003ePin Number\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eSignal Designation\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eFunctional Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV1+\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary DC Power Input (+)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV1-\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary DC Power Input (-)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFault\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRelay Contact (Normally Closed on failure)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFault\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRelay Contact (Normally Closed on failure)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV2+\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSecondary Redundant DC Power Input (+)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV2-\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSecondary Redundant DC Power Input (-)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The IE-SW-VL05M-3TX-2ST managed switch is a direct functional upgrade over unmanaged variants such as the IE-SW-VL05-3TX-2ST. When replacing an unmanaged switch with this managed unit, network administrators must configure the IP address and disable unused protocols to prevent broadcast storms. Ensure that the remote fiber transceiver matches the 1300 nm wavelength specification of this device's multimode ST ports.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  In high-temperature environments exceeding 50 degC, natural convection cooling is critical. Avoid mounting this switch directly adjacent to high-heat-dissipating components like power supplies or motor drives; maintain a minimum clearance of 25 mm on both sides. When calculating the fiber optic power budget, factor in a typical 5 km limit and account for connector attenuation (typically 0.75 dB per ST junction) to prevent signal degradation.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Always ground the IP30 metal chassis using the dedicated grounding screw located on the top panel to establish a low-impedance path for electrostatic discharge. When wiring redundant power supplies, connect V1 and V2 to separate physical power sources. This configuration allows the internal fault relay to trip and signal an external PLC alarm immediately if one of the power loops loses voltage.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all electrical power sources before attempting to wire or mount the switch. Do not plug or unplug the 6-pin terminal block while circuits are live, as this can cause electrical arcing and damage internal components.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eSnap the switch onto a standard TS 35 DIN rail, ensuring the DIN rail clip locks firmly into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect a dedicated grounding wire (minimum 14 AWG) from the chassis ground screw to the main cabinet earth ground.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the 12\/24\/48 V DC power lines to the removable 6-pin terminal block, then insert the block firmly into the switch socket.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eInsert the RJ45 copper communication cables and the ST-Duplex multimode fiber optic connectors into their respective ports.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102127579499,"sku":"IE-SW-VL05M-3TX-2ST","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-vl05m-3tx-2st-a2e2rkxptss.png?v=1776137763"},{"product_id":"weidmuller-1469510000-pro-eco-480w-24v-20a-pro-eco-switch-mode-power-supply-unit","title":"Weidmuller 1469510000 PRO ECO 480W 24V 20A PRO eco Switch-Mode Power Supply Unit","description":"\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEfficient power delivery in decentralized industrial automation systems is critical, and the \u003cstrong\u003eWeidmuller 1469510000\u003c\/strong\u003e switch-mode power supply unit is engineered to meet this demand. Operating within the PRO eco series, this robust power supply delivers a regulated 24 V DC output with up to 20 A of continuous current, translating to a nominal output power of 480 W. It features a wide-range AC input (85 to 264 V AC) and DC input (80 to 370 V DC) capability, making it highly adaptable to varying global grid conditions.\u003c\/p\u003e\n\n\u003cp\u003eThe compact, corrosion-resistant metal housing is optimized for space-constrained control cabinets, mounting directly onto standard TS 35 DIN rails. With an energy efficiency rating of 91%, the unit minimizes thermal dissipation, allowing reliable operation in ambient temperatures ranging from -25 degC to 70 degC. Integrated safety features include short-circuit protection, overload protection, over-temperature protection, and reverse voltage protection, ensuring maximum uptime for connected PLC, DCS, and I\/O systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-efficiency power conversion reaching up to 91% to reduce heat generation inside enclosures.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range supporting both AC (85 to 264 V AC) and DC (80 to 370 V DC) operation.\u003c\/li\u003e\n  \u003cli\u003eAdjustable output voltage from 22 to 28 V DC via a front-facing potentiometer for precise voltage drop compensation.\u003c\/li\u003e\n  \u003cli\u003eThree-stage LED diagnostic indicator for real-time visual status monitoring of output voltage and load conditions.\u003c\/li\u003e\n  \u003cli\u003eSupport for parallel connection of up to three units to increase total output capacity or establish redundancy.\u003c\/li\u003e\n  \u003cli\u003eRobust screw connection system ensuring secure, vibration-resistant wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Weidmuller PRO eco 480W power supply is designed for deployment in demanding industrial environments, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower generation and distribution control panels.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility automation.\u003c\/li\u003e\n  \u003cli\u003eOil and gas processing plant telemetry and DCS cabinets.\u003c\/li\u003e\n  \u003cli\u003eGeneral machinery manufacturing and factory automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePRO ECO 480W 24V 20A (Order No: 1469510000)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4050118275483\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85 to 264 V AC (derating at 100 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80 to 370 V DC (derating at 120 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.37 A @ 230 V AC \/ 5.2 A @ 110 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.55 A @ 370 V DC \/ 4.65 A @ 120 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC +\/- 1%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e22 to 28 V DC (adjustable via potentiometer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 A @ 55 degC, 15 A @ 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e480 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e91%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResidual Ripple \/ Breaking Spikes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 50 mVPP @ 24 V DC, IN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Failure Bridging Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt; 20 ms @ 230 V AC \/ \u0026gt; 20 ms @ 115 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Loss (Idling \/ Nominal Load)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 W \/ 43 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Permissible Air Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 mm x 125 mm x 120 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1557 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eStatus Indicator \/ Terminal\u003c\/th\u003e\n      \u003cth\u003eFunctional Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGreen LED\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOutput voltage is active and normal (Uoutput \u0026gt; 21.6 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eYellow LED\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHigh load warning (Ioutput \u0026gt; 90% IRated typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRed LED\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFault condition (overload, overtemperature, short-circuit, or Uoutput \u0026lt; 20.4 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew terminals for L, N, and PE connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew terminals for positive (+24 V DC) and negative (GND) connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap securely onto a standard TS 35 DIN rail. Ensure the unit is mounted vertically to facilitate natural convection cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm above and below the unit, and 10 mm on the sides when operating under full load conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriately rated copper conductors. Ensure all screw terminals are torqued to the manufacturer's specified limits to prevent contact resistance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the protective earth (PE) terminal to the local system ground busbar prior to energizing the input power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102127645035,"sku":"PRO ECO 480W 24V 20A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469510000-g0v45txmh4l.png?v=1776137076"},{"product_id":"weidmuller-8965460000-act20x-2sai-2hao-s-act20x-series-current-output-isolator","title":"Weidmuller 8965460000 ACT20X-2SAI-2HAO-S ACT20X Series Current Output Isolator","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nOperating as an essential barrier in hazardous process environments, the Weidmuller 8965460000 ACT20X-2SAI-2HAO-S provides high-integrity galvanic isolation and signal conversion for analog current loops. This dual-channel module isolates and converts standard current signals, ensuring safe and precise transmission between field devices in explosive atmospheres and safe-area control systems. Configured via standard \u003cstrong\u003eFDT\/DTM software\u003c\/strong\u003e, it delivers an exceptional accuracy of \u003cstrong\u003eless than 0.1% of span\u003c\/strong\u003e and a rapid step response time of \u003cstrong\u003e5 milliseconds or less\u003c\/strong\u003e, making it highly suitable for critical control loops.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDual-channel isolation (2SAI-2HAO) for space-saving DIN-rail density.\u003c\/li\u003e\n  \u003cli\u003eComprehensive diagnostic alarm functions for signal limit violations, input line interruptions, power loss, and internal device errors.\u003c\/li\u003e\n  \u003cli\u003eIntegrated alarm relay output supporting nominal switching voltages up to 125V AC or 110V DC.\u003c\/li\u003e\n  \u003cli\u003eSoftware-driven parameterization using FDT\/DTM frameworks for precise calibration and monitoring.\u003c\/li\u003e\n  \u003cli\u003eRobust IP20 housing with secure screw connection terminals for reliable field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIntrinsically safe signal isolation in chemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eField instrument coupling in oil and gas extraction and refining facilities.\u003c\/li\u003e\n  \u003cli\u003eAnalog signal conditioning in municipal water and wastewater treatment systems.\u003c\/li\u003e\n  \u003cli\u003eDistributed Control System (DCS) and PLC analog I\/O protection in heavy manufacturing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8965460000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eACT20X-2SAI-2HAO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e19.2...31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 1.8 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMeasurement Accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt; 0.1% of span\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStep Response Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 5 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTemperature Coefficient\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt; 0.01% of span \/ degC (TU)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAlarm Relay Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSignal limit exceeded, Line interruption, Supply failure, Device error\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNominal Switching Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 125 V AC \/ 110 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eContinuous Current Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0...95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.212 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.300 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe ACT20X-2SAI-2HAO-S is a direct fit for applications requiring dual-channel analog isolation with intrinsic safety ratings. When upgrading older ACT20M or non-Ex isolators, verify that the DIN rail spacing accommodates the 22.5 mm width of this module. Ensure that the latest Weidmuller DTM library is installed in your FDT frame application (such as WI-Manager) to recognize the firmware revision of this device.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen installing multiple ACT20X modules side-by-side in high-density control enclosures, calculate the cumulative thermal load. Each module dissipates up to 1.8W under full load. Maintain a minimum clearance or ensure active panel ventilation if ambient temperatures inside the cabinet regularly exceed 50 degC. Note that while the integrated alarm relay is rated for 125V AC, inductive loads must be equipped with external flyback diodes or RC snubbers to prevent contact welding.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nConfiguration must be performed using the dedicated Weidmuller interface cable connected to the front-panel service port. To prevent ground loops and potential damage to your configuration PC, do not connect field-side wiring while the USB configuration cable is active. Always ensure that the field-side intrinsically safe wiring is physically segregated from non-intrinsically safe wiring in compliance with local electrical codes (e.g., NEC Article 504 or EN 60079-14).\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all power sources before mounting, wiring, or configuring this device. Verify that no explosive atmospheres are present before opening the enclosure or connecting configuration interfaces. Failure to follow intrinsically safe installation protocols can result in electrical discharge, equipment destruction, or catastrophic ignition in hazardous areas.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Snap the module securely onto a standard TS 35 DIN rail. Ensure the metal rail-clip on the back of the module makes solid contact with the grounded DIN rail.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Connect the 24V DC power supply to the designated terminals, observing correct polarity (19.2...31.2 V DC range).\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Wire the intrinsically safe field inputs and safe-area outputs to the screw terminals according to the system schematic, ensuring correct torque is applied to the terminal screws.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Connect the configuration interface to parameterize the alarm thresholds, input ranges, and fault-state behaviors using the FDT\/DTM software.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102127972715,"sku":"8965460000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965460000-x5jbdgn4gcf.png?v=1776137164"},{"product_id":"weidmuller-1469520000-pro-eco-960w-24v-40a-switch-mode-power-supply-unit","title":"Weidmuller 1469520000 PRO ECO 960W 24V 40A Switch-mode Power Supply Unit","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for high-capacity DC power distribution in demanding industrial environments, the \u003cstrong\u003eWeidmuller 1469520000\u003c\/strong\u003e (Model: \u003cstrong\u003ePRO ECO 960W 24V 40A\u003c\/strong\u003e) switch-mode power supply unit delivers a regulated 24 V DC output at up to 40 A. This robust DIN-rail mountable module combines a compact form factor with 93% operational efficiency, minimizing thermal load inside control cabinets and ensuring stable power delivery to PLCs, HMIs, and field actuators.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Operational Efficiency:\u003c\/strong\u003e Achieves up to 93% efficiency, significantly reducing energy dissipation and cabinet heat buildup.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Input Range:\u003c\/strong\u003e Supports universal AC input from 85 to 264 V AC and DC input from 80 to 370 V DC for global compatibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTri-Color LED Diagnostics:\u003c\/strong\u003e Real-time status monitoring via Green (Uoutput \u0026gt; 21.6 V DC), Yellow (Ioutput \u0026gt; 90% rated), and Red (overload, short-circuit, or overtemperature) indicators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eParallel Capability:\u003c\/strong\u003e Supports direct parallel connection of up to 3 units to scale current capacity or establish redundant power architectures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Protection Suite:\u003c\/strong\u003e Integrated varistor surge protection, short-circuit protection, overload protection, and thermal shutdown.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Automation:\u003c\/strong\u003e Centralized 24 V DC power distribution for PLC racks, I\/O drops, and industrial PCs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Control Systems:\u003c\/strong\u003e Reliable power source for transmitters, solenoid valves, and safety barriers in continuous process plants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine Building:\u003c\/strong\u003e Heavy-duty power supply for packaging, material handling, and CNC machinery control panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and Wastewater:\u003c\/strong\u003e Robust power infrastructure for outdoor telemetry and pump control stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eOrder Number\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eType Designation\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eGTIN \/ EAN\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eStandard Package Qty\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1469520000\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePRO ECO 960W 24V 40A\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4050118275704\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 pc(s).\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePROeco\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 V DC ± 1 % (adjustable 22 to 28 V DC via potentiometer)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eContinuous Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e40 A @ 50 degC \/ 24 A @ 70 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e960 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAC Input Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85 to 264 V AC (derating required below 100 V AC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDC Input Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e80 to 370 V DC (derating required below 120 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAC Current Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4.6 A @ 230 V AC \/ 9.9 A @ 110 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFrequency Range AC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e47 to 63 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMax. 5 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEfficiency\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e93%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Loss (Idle \/ Nominal)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8 W (Idling) \/ 85 W (Nominal Load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnection System\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Version\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMetal, corrosion resistant\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-25 degC to 70 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e160 mm x 125 mm x 120 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3190 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eDiagnostic LED Status Mapping\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eLED Color\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eStatus \/ Threshold\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperational Meaning\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; color: green; font-weight: bold;\"\u003eGreen\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUoutput \u0026gt; 21.6 V DC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eNormal operation; output voltage within acceptable limits.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; color: #b7791f; font-weight: bold;\"\u003eYellow\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIoutput \u0026gt; 90% IRated typ.\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eHigh load warning; output current is approaching maximum capacity.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; color: red; font-weight: bold;\"\u003eRed\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUoutput \u0026lt; 20.4 V DC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFault condition; overload, overtemperature, short-circuit, or low voltage.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The PROeco series is designed as a highly space-efficient and cost-effective alternative to Weidmuller's premium PROmax and PROtop series. When replacing older 40 A power supplies, verify the 160 mm width footprint on the TS 35 rail, as high-power units require adequate lateral spacing for heat dissipation.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  A critical consideration for the PRO ECO 960W is its thermal derating profile. While it delivers a full 40 A at ambient temperatures up to 50 degC, the output capacity derates linearly to 24 A at 70 degC. Operating the unit near its limit in unventilated enclosures will trigger the internal thermal protection, causing output cycling.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Due to the high 40 A output current, ensure that output wiring is sized appropriately (minimum 10 AWG \/ 6 mm² copper wire recommended) to prevent significant voltage drop across the run. When configuring parallel operation for up to 3 units, use a precise digital multimeter to adjust the output voltage of each unit via the front potentiometer to within ±50 mV of each other before tying the outputs together.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all AC and DC power sources before attempting installation, wiring, or maintenance. Ensure the input circuit breaker is locked out. Do not open the metal housing; high residual voltage may remain stored in internal capacitors even after power is disconnected.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eSnap the unit securely onto a standard TS 35 DIN rail. Ensure the mounting orientation is vertical, with the input terminals at the bottom and output terminals at the top to facilitate natural convection cooling.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMaintain a minimum clearance of 50 mm above and below the unit, and 20 mm of lateral clearance from adjacent active heat-producing components.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the protective earth (PE) ground terminal first. Wire the AC input (L, N) or DC input terminals using the integrated screw connections, tightening to the manufacturer-specified torque.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the 24 V DC load lines to the output terminals, ensuring correct polarity. Energize the input source and verify that the green LED illuminates.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102129054059,"sku":"PRO ECO 960W 24V 40A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469520000-hqxom15pbh5.png?v=1776137078"},{"product_id":"weidmuller-8965380000-act20x-act20x-2hdi-2sdo-rnc-s-isolating-switch-amplifier","title":"Weidmuller 8965380000 ACT20X ACT20X-2HDI-2SDO-RNC-S Isolating Switch Amplifier","description":"\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for intrinsic safety applications, the **Weidmuller 8965380000** functions as a highly reliable 2-channel **isolating switch amplifier**. This device transmits digital signals from hazardous areas (Zone 0, 1, 2) to safe areas, providing complete galvanic isolation between the input, output, and power supply. It is specifically engineered to interface with NAMUR sensors and mechanical contacts, converting their states into digital relay outputs.\u003c\/p\u003e\n\n\u003cp\u003eThe **ACT20X-2HDI-2SDO-RNC-S** features integrated line fault detection (LFD) capable of identifying line interruptions or short circuits at the input. Diagnostic status and device errors are signaled via an integrated alarm contact, ensuring high system availability and simplified troubleshooting. Configuration is easily performed using standard FDT\/DTM software, allowing for precise adjustment of input types, output behavior, and diagnostic parameters.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-channel design for space-saving installation on standard DIN rails.\u003c\/li\u003e\n  \u003cli\u003eComplete 3-way galvanic isolation between input, output, and power supply.\u003c\/li\u003e\n  \u003cli\u003eSupports both NAMUR sensors and mechanical contact inputs.\u003c\/li\u003e\n  \u003cli\u003eIntegrated line fault detection (LFD) for short-circuit and wire-break monitoring.\u003c\/li\u003e\n  \u003cli\u003eDedicated alarm relay output for system diagnostics and error reporting.\u003c\/li\u003e\n  \u003cli\u003eSimple configuration and parameterization via FDT\/DTM software.\u003c\/li\u003e\n  \u003cli\u003eSecure screw connection terminals for reliable field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eOil and gas extraction, refining, and distribution.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eHazardous area signal isolation and safety-instrumented systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8965380000 \/ ACT20X-2HDI-2SDO-RNC-S\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIsolating Switch Amplifier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt;= 1.9 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNAMUR sensor (DIN EN 60947-5-6), switch contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNAMUR Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 V DC \/ 8 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRelay (2 NO contacts)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Switching Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt;= 125 V AC \/ 110 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt;= 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAlarm Function\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLine interruption at input, short circuit at input, no supply voltage, device error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFDT\/DTM software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmbient Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 95% (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-20 to +60 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e119.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.192 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Pin\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e11, 12\u003c\/td\u003e\n      \u003ctd\u003eInput Channel 1 (Hazardous Area)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e13, 14\u003c\/td\u003e\n      \u003ctd\u003eInput Channel 2 (Hazardous Area)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e51, 52\u003c\/td\u003e\n      \u003ctd\u003eOutput Channel 1 Relay (Safe Area)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e53, 54\u003c\/td\u003e\n      \u003ctd\u003eOutput Channel 2 Relay (Safe Area)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e41, 42\u003c\/td\u003e\n      \u003ctd\u003ePower Supply (19.2 to 31.2 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e43, 44\u003c\/td\u003e\n      \u003ctd\u003eAlarm Output Relay\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install vertically on a standard TS 35 DIN rail. Ensure the module is securely locked into place.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Maintain strict physical separation (at least 50 mm) between intrinsically safe (blue terminals) and non-intrinsically safe wiring to comply with safety standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail is connected to a low-impedance functional earth ground.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Provide sufficient clearance above and below the device to allow natural convection cooling and prevent heat accumulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eATEX\u003c\/li\u003e\n  \u003cli\u003eIECEx\u003c\/li\u003e\n  \u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102129480043,"sku":"8965380000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965380000-1wjyymauasm.png?v=1776137157"},{"product_id":"weidmuller-8965450000-act20x-sai-hao-s-current-output-isolator","title":"Weidmuller 8965450000 ACT20X-SAI-HAO-S Current Output Isolator","description":"\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for hazardous area applications, the \u003cstrong\u003eWeidmuller 8965450000\u003c\/strong\u003e (ACT20X-SAI-HAO-S) provides reliable galvanic isolation and signal conditioning for analog current outputs. This high-performance \u003cstrong\u003ecurrent output isolator\u003c\/strong\u003e safely transmits control signals from safe-area controllers to intrinsically safe (Ex i) actuators, control valves, or I\/P converters located in hazardous environments. Featuring an integrated alarm relay, the module monitors critical faults such as line interruptions, signal limit violations, and power supply failures, ensuring maximum process safety and system availability.\u003c\/p\u003e\n\n\u003cp\u003eThe device is fully configurable via standard FDT\/DTM software, allowing engineers to customize alarm thresholds and operational parameters to match specific process requirements. Its compact 22.5 mm housing design optimizes cabinet space, making it an ideal choice for high-density control panels in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGalvanic isolation between input, output, and power supply circuits.\u003c\/li\u003e\n  \u003cli\u003eIntrinsically safe (Ex i) output design for hazardous area field devices.\u003c\/li\u003e\n  \u003cli\u003eIntegrated alarm relay for real-time fault signaling and diagnostics.\u003c\/li\u003e\n  \u003cli\u003eFDT\/DTM software-based configuration for precise parameterization.\u003c\/li\u003e\n  \u003cli\u003eFast step response time of 5 ms or less for dynamic control loops.\u003c\/li\u003e\n  \u003cli\u003eCompact DIN-rail mountable housing with screw connection technology.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eOil and gas extraction, refining, and distribution.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facilities.\u003c\/li\u003e\n  \u003cli\u003ePower generation and utility control systems.\u003c\/li\u003e\n  \u003cli\u003eIntrinsic safety isolation for control valves, positioners, and I\/P converters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8965450000 (ACT20X-SAI-HAO-S)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCurrent Output Isolator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e19.2...31.2 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt;= 1.0 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 0.1% of span\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 0.01% of span \/ degC (TU)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStep Response Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt;= 5 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Switching Voltage (Alarm)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt;= 125 V AC \/ 110 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Current (Alarm)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt;= 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAlarm Functions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSignal limit exceeded, Line interruption at the input, No supply voltage, Device error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFDT\/DTM software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eType of Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0...95% (no condensation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.189 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the device vertically on a standard TS 35 DIN rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure adequate clearance around the module to facilitate natural convection cooling, especially when mounting multiple units side-by-side.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriate wire cross-sections for the screw terminals. Keep intrinsically safe (Ex i) field wiring physically separated from non-intrinsically safe power and signal wiring in compliance with local electrical codes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail is properly grounded to a low-impedance earth ground to maintain signal integrity and safety shielding.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102129578347,"sku":"8965450000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965450000-qiok44uu3fe.png?v=1776137165"},{"product_id":"weidmuller-ie-sw-bl05t-1gs-4gtpoe-basic-line-industrial-poe-switch","title":"Weidmuller IE-SW-BL05T-1GS-4GTPOE Basic Line Industrial PoE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFacilitating high-performance data distribution in demanding industrial environments, the \u003cstrong\u003eWeidmuller IE-SW-BL05T-1GS-4GTPOE\u003c\/strong\u003e (Article Number \u003cstrong\u003e1504380000\u003c\/strong\u003e) is a rugged, unmanaged Gigabit Ethernet PoE switch designed for reliable network expansion. This hardware solution features four Gigabit PoE+ ports and one Gigabit SFP slot, allowing for seamless integration of high-bandwidth devices and long-distance fiber-optic uplinks. Built to withstand harsh operational conditions, the unit is housed in a compact, IP30-rated aluminum enclosure and supports a wide operating temperature range.\u003c\/p\u003e\n\n\u003cp\u003eThe device utilizes a store-and-forward switching mechanism and supports jumbo frames up to 9.6 KB, ensuring efficient data transmission and minimized latency. With redundant dual power inputs, this switch provides high operational availability, making it suitable for critical infrastructure, security surveillance, and factory automation networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEquipped with 4 Gigabit PoE+ ports and 1 Gigabit SFP slot for versatile media connections.\u003c\/li\u003e\n  \u003cli\u003eSupports Jumbo Frames up to 9.6 KB to optimize high-throughput data transfers.\u003c\/li\u003e\n  \u003cli\u003eRedundant dual 24\/48 V DC power inputs ensure continuous network uptime.\u003c\/li\u003e\n  \u003cli\u003eRugged IP30 aluminum housing designed for space-saving DIN-rail or panel installation.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range from -40 degC to 75 degC for extreme environments.\u003c\/li\u003e\n  \u003cli\u003eStore-and-forward data switching with an 8 K MAC address table size.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial IP video surveillance and security systems.\u003c\/li\u003e\n  \u003cli\u003eFactory automation and distributed control networks.\u003c\/li\u003e\n  \u003cli\u003ePower utility, wind, and solar energy monitoring.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility communications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Article Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1504380000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIE-SW-BL05T-1GS-4GTPOE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSwitch Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnmanaged PoE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGigabit Ethernet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Switching\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStore and Forward\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMAC Table Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePacket Buffer Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,024 Kbit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eJumbo Frame Support\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 9.6 KB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24\/48 V DC (2 redundant inputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 removable 2-pole terminal blocks\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAluminium\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eType of Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e135 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e105 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e360 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface \/ Port\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePorts 1 to 4\u003c\/td\u003e\n      \u003ctd\u003e10\/100\/1000BaseT(X) PoE+ RJ45 ports\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePort 5\u003c\/td\u003e\n      \u003ctd\u003e1000BaseSFP slot for fiber-optic transceivers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Input\u003c\/td\u003e\n      \u003ctd\u003eDual redundant inputs via 2-pole removable terminal blocks\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap the device securely onto a standard TS 35 DIN rail. Ensure the DIN-rail clip is locked firmly in place. For panel mounting, use the optional mounting kit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the redundant power supplies to the terminal blocks. Ensure correct polarity and voltage range (24\/48 V DC) before powering the device.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional ground terminal on the switch to the local protective earth system to protect against electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm above and below the switch to facilitate natural convection cooling and prevent overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102130135403,"sku":"IE-SW-BL05T-1GS-4GTPOE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl05t-1gs-4gtpoe-zmo3b03g53c.png?v=1776137751"},{"product_id":"weidmuller-8965500000-act20-feed-in-pro-s-act20-series-power-feed-in-module","title":"Weidmuller 8965500000 ACT20-FEED-IN-PRO-S ACT20 Series Power Feed-In Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDesigned to optimize power distribution within modular DIN-rail systems, the \u003cstrong\u003eWeidmuller 8965500000 ACT20-FEED-IN-PRO-S\u003c\/strong\u003e provides a centralized feed-in point for the ACT20 series and CH20M bus system. This high-efficiency module simplifies cabinet wiring by distributing supply voltage directly to adjacent modules via the rail bus, reducing point-to-point wiring and minimizing installation time.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eHigh efficiency rating exceeding 97.9% to minimize thermal dissipation inside the enclosure.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range of 19.2 V DC to 31.2 V DC for compatibility with standard 24 V DC industrial power supplies.\u003c\/li\u003e\n  \u003cli\u003eIntegrated screw connection technology ensuring secure, vibration-resistant field wiring.\u003c\/li\u003e\n  \u003cli\u003eSupports collective error signaling and status monitoring for enhanced system diagnostics.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm width matching standard ACT20 series form factor to optimize DIN-rail space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eCentralized power distribution in industrial automation control panels.\u003c\/li\u003e\n  \u003cli\u003eSignal conditioning and isolation racks utilizing the CH20M rail bus system.\u003c\/li\u003e\n  \u003cli\u003eProcess industries requiring dense, modular DIN-rail instrument configurations.\u003c\/li\u003e\n  \u003cli\u003ePower grouping and segment isolation in complex PLC and DCS I\/O systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8965500000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eACT20-FEED-IN-PRO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePower Feed-In Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e\u0026lt;= 2.0 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEfficiency\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e\u0026gt; 97.9%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-20 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e119.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.140 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.20 kg (including protective packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput + \/ -\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary 24 V DC supply input connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCH20M Bus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDirect power distribution contacts to the DIN-rail bus\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStatus Relay\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCollective error message output (normally closed \/ normally open contact)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe ACT20-FEED-IN-PRO-S is fully compatible with all Weidmuller ACT20 series signal converters and isolators that utilize the CH20M DIN-rail bus. It can replace standard passive feed-in terminals when active collective error monitoring and diagnostic feedback are required for the control system.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nEnsure that the total current drawn by all modules connected to the CH20M bus does not exceed the maximum bus current rating (typically 4 A). If your module configuration exceeds this limit, you must install an additional feed-in module to segment the power distribution groups.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen wiring the collective error relay, integrate the contact into your PLC's safety loop or alarm input. This ensures that any power loss or module fault on the CH20M bus is instantly flagged in the control room, reducing troubleshooting downtime.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all primary and auxiliary power sources before mounting, removing, or wiring the module. Ensure the DIN-rail bus contacts are completely clean and properly aligned before snapping the unit onto the rail to prevent physical damage to the contact pins.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the CH20M DIN-rail bus elements onto the TS 35 DIN rail if they are not already installed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the ACT20-FEED-IN-PRO-S with the rail and snap it firmly into place, ensuring the bus connector pins seat correctly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 24 V DC input supply lines to the designated screw terminals using the correct wire gauge and torque specifications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the collective error relay output to your supervisory control system for active diagnostic monitoring.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102130594155,"sku":"8965500000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965500000-gdquort342v.png?v=1776137171"},{"product_id":"weidmuller-8965490000-act20x-hui-sao-s-universal-measurement-and-signal-isolating-converter","title":"Weidmuller 8965490000 ACT20X-HUI-SAO-S Universal Measurement and Signal Isolating Converter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eProcessing temperature and electrical signals from hazardous areas requires specialized, intrinsically safe isolation. The \u003cstrong\u003eWeidmuller 8965490000 ACT20X-HUI-SAO-S\u003c\/strong\u003e functions as a highly adaptable \u003cstrong\u003euniversal signal isolator\u003c\/strong\u003e and measurement converter, designed to condition, isolate, and convert analog signals from Ex Zone 0, 1, or 2 environments. This module accepts a wide range of inputs including RTDs, thermocouples, resistors, and active\/passive current or voltage signals, converting them into standard active or passive current\/voltage analog outputs.\u003c\/p\u003e\n\n\u003cp\u003eEquipped with an integrated alarm relay, the device provides rapid fault signaling in the event of sensor errors or power loss. Configuration is managed via standard FDT\/DTM software, allowing precise parameterization for diverse industrial applications. The compact 22.5 mm housing saves valuable DIN rail space while ensuring high galvanic isolation between the input, output, power supply, and relay contacts.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntrinsically safe input circuit (Ex ia) certified for Zone 0, 1, and 2 applications.\u003c\/li\u003e\n  \u003cli\u003eUniversal input capabilities supporting RTDs, thermocouples, potentiometers, resistance, and mA\/V signals.\u003c\/li\u003e\n  \u003cli\u003eFlexible analog output configurable for active or passive current and voltage loops.\u003c\/li\u003e\n  \u003cli\u003eIntegrated relay output for limit value monitoring and system alarm functions.\u003c\/li\u003e\n  \u003cli\u003eGalvanic 4-way isolation between input, output, power supply, and relay contacts.\u003c\/li\u003e\n  \u003cli\u003eFDT\/DTM software-based configuration for precise calibration and diagnostic monitoring.\u003c\/li\u003e\n  \u003cli\u003eSecure screw connection technology for reliable field wiring in high-vibration environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eOil and gas extraction, refining, and distribution.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facilities.\u003c\/li\u003e\n  \u003cli\u003ePower generation and thermal plant monitoring.\u003c\/li\u003e\n  \u003cli\u003eHazardous area signal conditioning and safety instrumented systems (SIS).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8965490000 (ACT20X-HUI-SAO-S)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUniversal Measurement and Signal Isolating Converter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤ 2.1 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRTD (Pt100, Pt500, Pt1000, Ni100, Ni120), Thermocouples (B, E, J, K, L, N, R, S, T, U, W3, W5), Resistance (10 Ohm to 10 kOhm), Voltage (± 20 mV to ± 10 V), Current (± 20 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Types\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eActive\/Passive Current (0\/4 to 20 mA), Voltage (0 to 10 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelay Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 NO contact (Alarm function: No supply voltage, Device error)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Switching Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤ 125 V AC \/ 110 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFDT\/DTM software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-20 degC to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-20 degC to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 95% (no condensation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.202 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Pin\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e11, 12\u003c\/td\u003e\n      \u003ctd\u003ePower Supply (+ \/ -)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e13, 14\u003c\/td\u003e\n      \u003ctd\u003eAnalog Output (+ \/ -)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e21, 22\u003c\/td\u003e\n      \u003ctd\u003eRelay Output (Alarm \/ Fault)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e41, 42, 43, 44\u003c\/td\u003e\n      \u003ctd\u003eSensor Input (RTD, Thermocouple, Resistance, Voltage, Current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap securely onto standard TS 35 DIN rails in a vertical orientation to optimize heat dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Maintain a minimum distance of 50 mm between intrinsically safe (Ex i) field wiring and non-intrinsically safe power\/control cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail is properly bonded to the protective earth (PE) system of the enclosure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Perform software configuration and parameterization via the FDT\/DTM interface prior to commissioning the system in hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eATEX (II (1) G [Ex ia Ga] IIC\/IIB\/IIA)\u003c\/li\u003e\n  \u003cli\u003eIECEx\u003c\/li\u003e\n  \u003cli\u003ecULus (Class I, Division 2, Groups A, B, C, D)\u003c\/li\u003e\n  \u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102130692459,"sku":"8965490000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965490000-uob5anrxys5.png?v=1776137169"},{"product_id":"weidmuller-1504460000-ie-gw-mb-2tx-1rs232-485-modbus-tcp-rtu-gateway","title":"Weidmuller 1504460000 IE-GW-MB-2TX-1RS232\/485 Modbus TCP \/ RTU Gateway","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Bridging the gap between legacy serial infrastructure and modern industrial Ethernet networks is efficiently managed by the Weidmuller 1504460000 (Model IE-GW-MB-2TX-1RS232\/485), a high-reliability Modbus TCP to RTU\/ASCII gateway. This device enables seamless communication between Modbus TCP clients and up to 31 Modbus RTU\/ASCII serial slave devices, ensuring high-speed data translation across diverse automation layers.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDual Ethernet ports (2TX) allowing simple daisy-chaining and reducing external switch requirements.\u003c\/li\u003e\n  \u003cli\u003eSoftware-selectable serial interface supporting RS-232, RS-422, and 2-wire or 4-wire RS-485 modes.\u003c\/li\u003e\n  \u003cli\u003eRedundant 24 V DC power inputs to maximize system uptime and prevent single-point-of-failure shutdowns.\u003c\/li\u003e\n  \u003cli\u003eIntegrated serial redirection and priority control for optimized packet routing and low-latency response times.\u003c\/li\u003e\n  \u003cli\u003eCompact, space-saving IP30 plastic housing designed for standard TS 35 DIN rail installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eSCADA integration of legacy serial PLCs, power meters, and flow sensors.\u003c\/li\u003e\n  \u003cli\u003eSubstation automation and energy management systems.\u003c\/li\u003e\n  \u003cli\u003eFactory floor device networking and distributed control system (DCS) expansion.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility monitoring networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1504460000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIE-GW-MB-2TX-1RS232\/485\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 x RJ45 (10\/100BaseT(X)), Auto MDI\/MDI-X\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSerial Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x RS-232\/422\/485 (Software Selectable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC (Redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x Removable 7-pole terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 degC to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDIN rail (TS 35)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e29 mm x 124.5 mm x 89.2 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e190 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal \/ Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunction Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1+ (Primary Power Input +)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1- (Primary Power Input -)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFunctional Earth \/ Ground\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2+ (Redundant Power Input +)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2- (Redundant Power Input -)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRelay Contact (Fault Output)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 7\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRelay Contact (Fault Output)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The IE-GW-MB-2TX-1RS232\/485 serves as a direct upgrade path for older serial-to-Ethernet converters. It is fully compatible with standard Modbus TCP client drivers found in modern PLC platforms (such as Siemens S7, Rockwell ControlLogix, and Schneider Modicon) without requiring custom driver blocks.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When configuring RS-485 2-wire communication, ensure that the appropriate termination resistors (typically 120 ohms) are installed at both physical ends of the serial bus. Failure to terminate the line can result in signal reflection, leading to intermittent CRC errors and communication timeouts, especially at baud rates exceeding 19200 bps.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Initial setup is performed via the integrated web-based management interface. Ensure your commissioning PC is configured on the same subnet as the gateway's default factory IP address. Always ground the functional earth pin (Pin 3) to the central cabinet ground plane to safeguard the internal transceiver components against transient voltage spikes.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Isolate all power sources before mounting, wiring, or servicing the gateway. Do not insert or remove the 7-pole terminal block while the circuits are energized to prevent electrical arcing and potential damage to the internal electronics.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eSnap the gateway securely onto a standard TS 35 DIN rail, ensuring the metal grounding spring on the rear makes firm contact with the rail.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the serial communication lines (RS-232 or RS-485) to the designated serial port interface using shielded cabling.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the redundant 24 V DC power supplies to the 7-pole terminal block, ensuring correct polarity before plugging the connector into the unit.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the RJ45 Ethernet cables to the 2TX ports to integrate the gateway into your local industrial Ethernet network.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102130954603,"sku":"IE-GW-MB-2TX-1RS232\/485","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-gw-mb-2tx-1rs232485-ghblsedxsrc.png?v=1776137749"},{"product_id":"weidmuller-1504350000-ie-sw-vl05mt-3tx-2sc-valueline-managed-industrial-ethernet-switch","title":"Weidmuller 1504350000 IE-SW-VL05MT-3TX-2SC ValueLine Managed Industrial Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered to maintain reliable communication links in high-interference environments, the \u003cstrong\u003eWeidmuller 1504350000 IE-SW-VL05MT-3TX-2SC\u003c\/strong\u003e is a managed ValueLine Industrial Ethernet Switch featuring three RJ45 ports and two multimode SC-Duplex fiber optic ports. This device provides robust network management, ring redundancy, and traffic prioritization directly at the field level, making it ideal for critical infrastructure and demanding automation networks.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManaged Network Control:\u003c\/strong\u003e Supports essential management functions including VLAN, QoS, IGMP Snooping, and port mirroring for optimized bandwidth control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFiber Optic Connectivity:\u003c\/strong\u003e Equipped with two 100BaseFX multimode fiber ports utilizing SC-Duplex connectors for noise-immune data transmission up to 5 km.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Temperature Range:\u003c\/strong\u003e Certified for operation in extreme environments from -40 degC to 75 degC without active cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Inputs:\u003c\/strong\u003e Dual 12\/24\/48 V DC power inputs ensure continuous operation in the event of a primary power supply failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Housing:\u003c\/strong\u003e Housed in a rugged IP30-rated metal enclosure designed to withstand high mechanical shock and vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eWind power generation and solar farm monitoring networks.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility control systems.\u003c\/li\u003e\n  \u003cli\u003eFactory automation and machine-to-machine (M2M) communication.\u003c\/li\u003e\n  \u003cli\u003eOil and gas pipeline monitoring and distributed RTU networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1504350000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIE-SW-VL05MT-3TX-2SC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eManaged (ValueLine)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3x 10\/100BaseT(X), auto negotiation, full\/half duplex, auto MDI\/MDI-X\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFiber Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2x 100BaseFX, Multimode, SC-Duplex connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTransmission Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5 km (typical over 50\/125 or 62.5\/125 um multimode fiber)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWavelength\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1310 nm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e12 \/ 24 \/ 48 V DC (Redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 degC to 75 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 Mbit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMetal (IP30 protection degree)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDIN rail (TS 35), Panel mounting (with optional kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e53.6 mm x 135 mm x 105 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e650 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eTerminal Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSignal Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eDescription\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV1+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC Power Input 1 (Positive)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV1-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC Power Input 1 (Negative \/ Common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSTATE (NC)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFault Relay Output (Normally Closed)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSTATE (COM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFault Relay Output (Common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV2+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC Power Input 2 (Positive)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 6\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV2-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC Power Input 2 (Negative \/ Common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis managed switch serves as a direct upgrade to the unmanaged IE-SW-VL05-3TX-2SC series, offering advanced diagnostics and ring redundancy protocols (such as Turbo Ring or RSTP) to prevent network loops. When replacing older revisions, verify that the existing network management software or PLC configuration supports standard SNMP or the specific Weidmuller ring topology parameters.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen deploying the multimode SC-Duplex ports over long distances, ensure that the total optical power budget does not exceed the receiver's saturation limits. For short-run fiber connections (under 100 meters), optical attenuators are generally not required, but clean fiber end-faces are critical to prevent packet loss. Ensure the switch is mounted vertically on the DIN rail to facilitate natural convection cooling, especially when operating near the upper thermal limit of 75 degC.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo ensure electromagnetic compatibility (EMC), connect the functional earth (FE) terminal on the DIN-rail ground block directly to a low-impedance earth ground. When wiring the redundant power inputs, use a wire gauge between 12 and 24 AWG. Tighten the terminal block screws to a torque of 0.5 Nm to prevent loose connections under high-vibration conditions.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDe-energize all power sources before connecting or disconnecting the 6-pin terminal block. Do not insert or remove fiber optic cables while the transceiver is active to avoid potential eye injury from invisible laser radiation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSnap the switch onto the TS 35 DIN rail, ensuring the top hook engages first, then push the bottom of the unit until the metal latch clicks securely into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the functional ground terminal to the local protective earth system using a short, heavy-gauge wire.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the RJ45 copper network cables and the SC-Duplex multimode fiber optic cables into their designated ports until they lock in place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the redundant power supplies to the 6-pin terminal block, plug the block into the switch, and apply power to verify status via the front-panel LED indicators.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102131183979,"sku":"IE-SW-VL05MT-3TX-2SC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-vl05mt-3tx-2sc-zzabviscdoc.png?v=1776137765"},{"product_id":"weidmuller-1504220000-ie-sw-bl06t-4poe-2sc-unmanaged-poe-switch","title":"Weidmuller 1504220000 IE-SW-BL06T-4POE-2SC Unmanaged PoE Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Facilitating reliable data distribution and power delivery in demanding industrial networks, the \u003cstrong\u003eWeidmuller IE-SW-BL06T-4POE-2SC\u003c\/strong\u003e (part number \u003cstrong\u003e1504220000\u003c\/strong\u003e) functions as a robust, unmanaged Fast Ethernet switch. This unit integrates four Power over Ethernet (PoE) ports alongside two multimode fiber optic ports to bridge long-distance field communications with local IP-enabled hardware.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Port Architecture:\u003c\/strong\u003e Equipped with 4 RJ45 PoE ports and 2 multimode SC-Duplex fiber ports.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Optical Range:\u003c\/strong\u003e Supports transmission distances up to 5 km over multimode fiber.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Inputs:\u003c\/strong\u003e Dual power inputs support 12\/24\/48 V DC configurations to ensure continuous uptime.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Housing:\u003c\/strong\u003e IP30-rated aluminum enclosure designed for space-constrained DIN rail installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStore-and-Forward Technology:\u003c\/strong\u003e Optimizes data packet delivery and prevents collision propagation across the local network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIP-based video surveillance systems in manufacturing and processing plants.\u003c\/li\u003e\n  \u003cli\u003eDistributed control system (DCS) and PLC networking in municipal water treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eSCADA telemetry integration in remote wind, solar, or oil and gas installations.\u003c\/li\u003e\n  \u003cli\u003eTraffic monitoring and intelligent transportation system (ITS) roadside cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504220000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-BL06T-4POE-2SC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnmanaged PoE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100 Mbps (Fast Ethernet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransceiver Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMultimode\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSC-Duplex\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTypical Transmission Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 km\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e12\/24\/48 V DC (2 redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e64.56 A at 48 V DC (0.1 to 1 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e768 kBit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 75 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 mm x 115 mm x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e375 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterface \/ Connection\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eDescription \u0026amp; Pin Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePorts 1 to 4 (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10\/100BaseT(X) auto-negotiation, PoE+ power sourcing capability.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePorts 5 \u0026amp; 6 (SC-Duplex)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100BaseFX multimode fiber optic interface for uplink\/backbone connections.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Input Terminal\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 removable 4-pin terminal block for redundant DC power inputs (V1+, V1-, V2+, V2-).\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eGrounding Screw\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eChassis ground terminal located on the top panel for EMI shielding.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The IE-SW-BL06T-4POE-2SC serves as a direct drop-in replacement for older unmanaged switches within the Weidmuller BasicLine series. When migrating from non-PoE variants (such as the standard IE-SW-BL06-2SC), ensure that the power supply rating is upgraded to accommodate the additional PoE power budget required by downstream field devices.\n\u003c\/p\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  While the switch supports a wide input range of 12\/24\/48 V DC, full IEEE 802.3at\/af PoE output standard compliance typically requires a stable 48 V DC input supply. Operating the switch on 12 V DC or 24 V DC inputs may limit the PoE voltage boost capability or reduce the maximum deliverable wattage per port. Always verify the total power budget of connected PDs (Powered Devices) against the available input power capacity.\n\u003c\/p\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  To prevent communication drops caused by high electromagnetic interference (EMI) in motor control centers, ensure the chassis grounding screw is connected to the local DIN rail or functional earth using a minimum of 14 AWG copper wire. When deploying the SC-Duplex fiber ports, verify that the TX (transmit) port of the switch connects to the RX (receive) port of the remote media converter or switch.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all power sources before mounting, wiring, or servicing this equipment. High inrush currents (up to 64.56 A) can cause severe arcing if connections are made under load. Verify that the input voltage matches the specified range on the product label before applying power.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSnap the switch onto a standard TS 35 DIN rail. Ensure the DIN rail clip locks securely into place to prevent physical movement during operation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the functional earth ground wire to the grounding screw located on the top panel of the switch housing.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the redundant DC power supplies to the 4-pin removable terminal block connector. Tighten the terminal screws to 0.5 Nm to prevent loose connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the RJ45 Ethernet cables into ports 1 through 4, and connect the SC-Duplex fiber optic cables to ports 5 and 6.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102131741035,"sku":"IE-SW-BL06T-4POE-2SC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06t-4poe-2sc-fqn2yyej3sk.png?v=1776137759"},{"product_id":"weidmuller-ie-sw-vl05m-5tx-value-line-managed-industrial-ethernet-switch","title":"Weidmuller IE-SW-VL05M-5TX Value Line Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe \u003cstrong\u003eWeidmuller IE-SW-VL05M-5TX\u003c\/strong\u003e (article number \u003cstrong\u003e1504280000\u003c\/strong\u003e) is a managed industrial Ethernet switch engineered to provide reliable, high-availability data routing across rugged automation networks. Featuring five Fast Ethernet ports, this infrastructure device utilizes an advanced store-and-forward switching architecture to eliminate corrupt data packets and maintain deterministic communication links between control elements. \n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe switch is enclosed in a robust, compact IP30-rated metal housing designed for space-critical DIN rail configurations without sacrificing mechanical resistance to thermal stress. Equipped with integrated layer 2 management software tools, network administrators can actively configure traffic prioritization, secure interface access ports, and monitor diagnostics. Redundant dual power supply inputs are built into the design, protecting continuous SCADA operations, distributed I\/O clusters, and field networks from sudden primary power failures.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFive Fast Ethernet Ports\u003c\/strong\u003e: Equipped with 5 x RJ45 ports that automatically adjust line parameters via auto-negotiation and auto-MDI\/MDI-X link matching.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eManaged Layer 2 Architecture\u003c\/strong\u003e: Supports advanced configuration profiles for traffic filtering, system monitoring, and industrial segment optimization.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFail-Safe Redundant Power\u003c\/strong\u003e: Dual power inputs accommodate wide supply ranges to prevent network failure if an external supply loop drops out.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRobust Traffic Buffer\u003c\/strong\u003e: Contains a 2 K MAC address capacity table and a 1 Mbit packet buffer memory allocation to manage burst traffic queues effectively.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHeavy-Duty IP30 Metal Casing\u003c\/strong\u003e: Slim, ruggedized aluminum\/steel outer structure built to resist shock, vibration, and thermal extremes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eFactory automation cells and continuous machine-to-machine (M2M) network coordination.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003ePower generation facilities, wind farms, and renewable energy substation data aggregation.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eWater and wastewater treatment infrastructure demanding high-uptime remote telemetry monitoring.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eOil, gas, and petrochemical process loops requiring robust hardware resilient against electrical ambient noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number \/ Model\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-VL05M-5TX\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504280000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Line Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eValue Line\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eData Switching Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStore and Forward\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePort Interface Count\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 x RJ45 ports (10\/100BaseT(X))\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNetwork Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFast Ethernet\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 Mbit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eVoltage Supply Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e12 \/ 24 \/ 48 V DC (Includes 2 redundant power inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Input Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 x removable 6-pin terminal block assembly\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMetal\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Degree Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Profiles\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTS 35 DIN rail, Panel mounting (requires optional expansion kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-10 Celsius to 60 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 Celsius to 85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAmbient Humidity Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eChassis Dimension Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e135 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eChassis Dimension Height\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e135 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eChassis Dimension Depth\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e105 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Unit Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e650 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe IE-SW-VL05M-5TX is standard component within Weidmuller’s industrial Value Line automation segment. When network requirements mandate fiber link conversions over longer runs, sister hardware configurations within the same catalog portfolio—such as versions incorporating multi-mode (MM) or single-mode (SM) fiber ports—must be utilized. It drop-in integrates with standard industrial hardware topologies, including PLC nodes, automation servers, and smart sensors utilizing standard RJ45 networking pathways.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nAn oversight often encountered during field setups involves ignoring proper chassis potential grounding. Failing to ground the metal housing through the designated chassis grounding screw lowers the switch's protection thresholds against transient voltage surges, exposing data paths to electromagnetic interference (EMI) originating from nearby heavy switching drives. Furthermore, because the unit features an IP30-rated chassis, it possesses no liquid protection; deploying this hardware in spaces exposed to water mist or condensing humidity conditions without an auxiliary IP65 protective junction box will cause electrical shorts and internal card degradation.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDIN Rail Fastening:\u003c\/strong\u003e Align the rear mounting assembly of the switch with a standardized TS 35 DIN rail frame. Tilt the unit back smoothly until the integrated mounting clip clicks firmly onto the upper and lower lips of the rail.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eThermal Distribution Clearances:\u003c\/strong\u003e Provide a minimum unhindered boundary gap of at least 5 cm above and below the module housing inside control panels to support normal convective airflow currents and prevent heat buildup.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFunctional Ground Termination:\u003c\/strong\u003e Connect a low-impedance copper grounding strap between the dedicated grounding point on the module body and the cabinet's central star ground bar.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003ePower Terminal Setup:\u003c\/strong\u003e Strip the external supply lines and hook up the redundant power wires (ranging between 12 and 48 V DC) to the matching slots of the removable 6-pin screw terminal block. Double-check all connection points for correct polarity before re-energizing the main power circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102132035947,"sku":"IE-SW-VL05M-5TX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-vl05m-5tx-b2nkfkxlagw.png?v=1776137764"},{"product_id":"weidmuller-1504340000-ie-sw-bl05t-1gt-4gtpoe-gigabit-poe-unmanaged-switch","title":"Weidmuller 1504340000 IE-SW-BL05T-1GT-4GTPOE Gigabit PoE Unmanaged Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding high-performance Gigabit connectivity in harsh electromagnetic environments, the \u003cstrong\u003eWeidmuller\u003c\/strong\u003e \u003cstrong\u003eIE-SW-BL05T-1GT-4GTPOE\u003c\/strong\u003e (part number \u003cstrong\u003e1504340000\u003c\/strong\u003e) unmanaged industrial Ethernet switch integrates Power over Ethernet (PoE+) capabilities to streamline field device deployment. This ruggedized network switch features four Gigabit PoE+ ports and one Gigabit standard uplink port, delivering reliable data transmission and power distribution over a single cable to compatible field devices.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eFour 10\/100\/1000BaseT(X) PoE+ ports and one 10\/100\/1000BaseT(X) RJ45 uplink port.\u003c\/li\u003e\n  \u003cli\u003eExtended operating temperature range of -40 to 75 degC for deployment in extreme climates.\u003c\/li\u003e\n  \u003cli\u003eRedundant dual power inputs (12\/24\/48 V DC) to maximize network availability.\u003c\/li\u003e\n  \u003cli\u003eRobust IP30-rated aluminum housing designed for space-constrained DIN rail installations.\u003c\/li\u003e\n  \u003cli\u003eJumbo frame support up to 10 KB to optimize high-bandwidth data transfers.\u003c\/li\u003e\n  \u003cli\u003eStore-and-Forward switching architecture with an 8 K MAC address table.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP Video Surveillance:\u003c\/strong\u003e Powering and networking high-definition security cameras in outdoor or industrial perimeters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Automation:\u003c\/strong\u003e Aggregating high-speed data from PLCs, HMIs, and distributed I\/O blocks on the factory floor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTraffic Control Systems:\u003c\/strong\u003e Reliable data backhaul and power delivery for roadside sensors and signaling equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504340000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-BL05T-1GT-4GTPOE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnmanaged PoE (Power over Ethernet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTotal Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 (4x RJ45 PoE+, 1x RJ45 Uplink)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eGigabit Ethernet (10\/100\/1000 Mbps)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eData Switching Mode\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStore and Forward\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1,024 Kbit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eJumbo Frame Support\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUp to 10 KB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e12\/24\/48 V DC, 2 redundant inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e17.4 A at 24 V DC (0.1 to 1 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDIN rail\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 75 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 to 95 % (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e29 x 135 x 105 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e360 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; text-align: left; font-weight: bold; width: 40%;\"\u003eInterface \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; text-align: left; font-weight: bold;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePorts 1 to 4 (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10\/100\/1000BaseT(X) auto-negotiation, PoE+ power sourcing equipment (PSE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePort 5 (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10\/100\/1000BaseT(X) standard Gigabit Ethernet uplink (no PoE output)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Input Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 removable 2-pole terminal blocks for redundant DC power connections\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe T-suffix in the model designation indicates an extended temperature rating (-40 to 75 degC), making it a direct drop-in replacement for standard-temperature variants in harsh environments. It is fully backward compatible with standard 10\/100 Mbps Fast Ethernet devices, automatically negotiating speed and duplex settings.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBe mindful of the switch's high inrush current of 17.4 A at 24 V DC during startup (lasting up to 1 ms). Ensure upstream power supplies and circuit breakers are sized to handle this transient load without tripping or causing voltage sags that could affect adjacent control hardware.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo achieve true power redundancy, connect the two removable 2-pole terminal blocks to separate, independent industrial power supplies. Always ground the switch housing using the integrated grounding screw to minimize electromagnetic interference and protect internal circuitry from electrostatic discharge.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDe-energize all power sources before connecting or disconnecting the terminal blocks. Do not hot-plug the power terminals or exceed the maximum rated input voltage, as this can cause permanent damage to the switch and connected PoE devices.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSnap the switch securely onto a standard TS 35 DIN rail, ensuring the top hook engages first before pressing the bottom of the unit until it clicks into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect a dedicated functional ground wire from the chassis grounding screw to the main panel ground busbar.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the redundant DC power sources to the removable terminal blocks, ensuring correct polarity, and plug them firmly into the switch.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the RJ45 network cables. The auto-MDI\/MDI-X feature eliminates the need for crossover cables when connecting to other switches or end devices.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102132855147,"sku":"IE-SW-BL05T-1GT-4GTPOE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl05t-1gt-4gtpoe-vr4himfuhwq.png?v=1776137752"},{"product_id":"weidmuller-1504440000-ie-wallmount-kit-46mm-industrial-ethernet-wall-mounting-kit","title":"Weidmuller 1504440000 IE-WALLMOUNT-KIT-46MM Industrial Ethernet Wall Mounting Kit","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to facilitate alternative mounting configurations, the \u003cstrong\u003eWeidmuller 1504440000\u003c\/strong\u003e (Type: \u003cstrong\u003eIE-WALLMOUNT-KIT-46MM\u003c\/strong\u003e) provides a rugged mechanical solution for direct wall-mounting of standard DIN rail-based Industrial Ethernet switches and modules. This kit allows field engineers to bypass traditional TS35 DIN rail requirements, enabling secure installation of active and passive communication hardware directly onto machine frames, control cabinet walls, or flat structural surfaces.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eEnables secure, flat-surface wall mounting of 46mm wide Industrial Ethernet components.\u003c\/li\u003e\n  \u003cli\u003eRobust metallic construction ensures long-term mechanical stability in high-vibration industrial environments.\u003c\/li\u003e\n  \u003cli\u003eLow-profile integration optimizes depth clearance inside shallow enclosures and field distribution boxes.\u003c\/li\u003e\n  \u003cli\u003eFully compliant with RoHS environmental standards for sustainable deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial control panels and enclosures lacking standard TS35 DIN rails.\u003c\/li\u003e\n  \u003cli\u003eDirect machine-frame mounting of Ethernet switches in manufacturing and CNC environments.\u003c\/li\u003e\n  \u003cli\u003eField-level distribution boxes with strict depth and space constraints.\u003c\/li\u003e\n  \u003cli\u003eInfrastructure and building automation networks requiring decentralized device placement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003ePart Number\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eType Designation\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eDescription\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eCompatible Width\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1504440000\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIE-WALLMOUNT-KIT-46MM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eWall mounting kit for Industrial Ethernet components\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e46 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1504440000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eType\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIE-WALLMOUNT-KIT-46MM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFunction\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMounting kit for alternative wall-mounting of DIN rail-based components\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCompatible Device Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e46 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e29 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.25 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEnvironmental Compliance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRoHS Conform\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis mounting kit is specifically engineered for Weidmuller active switches and passive modules with a housing width of exactly 46 mm. Before deployment, verify that the physical footprint, screw-hole alignment, and depth of your specific switch model match the mounting bracket dimensions to ensure a flush, secure fit.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen mounting active Ethernet switches flat against a wall or machine panel using the IE-WALLMOUNT-KIT-46MM, natural convection airflow is altered compared to standard vertical DIN rail mounting. System designers must ensure that the ambient temperature of the mounting surface and surrounding air does not exceed the maximum operating temperature of the active device, as heat dissipation efficiency may be slightly reduced without the standard DIN rail air gap.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo maintain proper electromagnetic compatibility (EMC) and functional grounding, ensure that the mounting screws make direct, paint-free contact with both the metal chassis of the switch and the grounded mounting surface. If mounting to a painted or non-conductive surface, run a dedicated functional earth (FE) strap from the switch ground terminal to the local ground busbar.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eBefore installing or servicing any active network components, ensure all power supplies feeding the device are completely de-energized. Failure to isolate power prior to mechanical installation can result in equipment damage or unexpected electrical discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the wall-mounting brackets with the pre-drilled mounting holes on the rear of the 46mm Weidmuller device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSecure the brackets to the device chassis using the recommended OEM screws, tightening to the specified torque rating to prevent thread damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePosition the assembled unit against the flat mounting surface, mark the pilot holes, and secure the assembly using appropriate heavy-duty fasteners suitable for the wall material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify mechanical rigidity and establish the functional ground connection before re-applying power to the device.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102132920683,"sku":"IE-WALLMOUNT-KIT-46MM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-wallmount-kit-46mm-ww5nnoete0s.png?v=1776137768"},{"product_id":"weidmuller-ie-wallmount-kit-30mm-1504450000-industrial-ethernet-wall-mounting-kit","title":"Weidmuller IE-WALLMOUNT-KIT-30MM 1504450000 Industrial Ethernet Wall Mounting Kit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered to facilitate flexible installation of network hardware, the Weidmuller \u003cstrong\u003eIE-WALLMOUNT-KIT-30MM\u003c\/strong\u003e (Article Number \u003cstrong\u003e1504450000\u003c\/strong\u003e) provides a reliable mechanical solution for adapting standard DIN rail-mounted Industrial Ethernet components to flat-surface wall installations. This mounting kit eliminates the requirement for a dedicated DIN rail section in compact enclosures or open-wall setups, allowing direct integration of switches, routers, and media converters into diverse industrial environments. By utilizing this robust adapter, engineers can optimize space utilization within control cabinets and field enclosures while maintaining secure device positioning.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnables alternative wall-mounting of top-hat DIN rail-based components.\u003c\/li\u003e\n  \u003cli\u003eCompatible with 30mm wide Industrial Ethernet modules.\u003c\/li\u003e\n  \u003cli\u003eLightweight, robust mechanical design minimizing additional load on mounting surfaces.\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant construction ensuring adherence to environmental safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial control panels and compact electrical enclosures.\u003c\/li\u003e\n  \u003cli\u003eTelecommunication and network distribution cabinets.\u003c\/li\u003e\n  \u003cli\u003eFactory automation networks with limited DIN rail space.\u003c\/li\u003e\n  \u003cli\u003eField-level device mounting in harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIE-WALLMOUNT-KIT-30MM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArticle Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1504450000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWall Mounting Kit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAlternative wall-mounting of DIN rail-based (top-hat type) components\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure secure installation of your Industrial Ethernet components, follow these engineering guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSecurely fasten the mounting kit to the wall or flat surface using appropriate mounting screws suitable for the substrate material.\u003c\/li\u003e\n  \u003cli\u003eAlign the Industrial Ethernet component's DIN rail clip mechanism with the mounting kit adapter interface.\u003c\/li\u003e\n  \u003cli\u003ePress the component onto the adapter until the locking mechanism fully engages and clicks into place.\u003c\/li\u003e\n  \u003cli\u003eVerify mechanical stability by gently pulling on the module to ensure it does not detach under vibration.\u003c\/li\u003e\n  \u003cli\u003eMaintain adequate clearance around the mounted device to allow proper ventilation and prevent cable strain.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRoHS: Conform\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102133215595,"sku":"IE-WALLMOUNT-KIT-30MM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-wallmount-kit-30mm-krej0qb3e2q.png?v=1776137767"},{"product_id":"weidmuller-8965340000-act20x-hdi-sdo-rno-s-isolating-switch-amplifier","title":"Weidmuller 8965340000 ACT20X-HDI-SDO-RNO-S Isolating Switch Amplifier","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eProcessing digital signals from hazardous zones requires robust galvanic isolation and signal conditioning. The \u003cstrong\u003eWeidmuller 8965340000\u003c\/strong\u003e functions as an intrinsically safe \u003cstrong\u003eisolating switch amplifier\u003c\/strong\u003e designed to interface NAMUR sensors or mechanical contacts located in Ex zones 0, 1, and 2 with safe-area controllers. This dual-channel module provides reliable signal transmission while ensuring complete electrical isolation between the input, output, and power supply circuits. Configurable via FDT\/DTM software, the device allows for precise parameterization of line monitoring (wire break and short-circuit detection) and output behavior.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-channel signal transmission for space-saving DIN rail installation.\u003c\/li\u003e\n  \u003cli\u003eIntrinsically safe input circuits compatible with NAMUR sensors (EN 60947-5-6) and dry contacts.\u003c\/li\u003e\n  \u003cli\u003eRelay outputs (normally open) for switching AC\/DC loads.\u003c\/li\u003e\n  \u003cli\u003eComprehensive line fault detection (LFD) for identifying short circuits or cable breaks.\u003c\/li\u003e\n  \u003cli\u003eGalvanic 3-way isolation between input, output, and power supply.\u003c\/li\u003e\n  \u003cli\u003eFDT\/DTM software configuration for flexible parameter adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003eOil and gas extraction and refining facilities\u003c\/li\u003e\n  \u003cli\u003eWastewater treatment and hazardous material storage\u003c\/li\u003e\n  \u003cli\u003ePower generation and distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8965340000 (ACT20X-HDI-SDO-RNO-S)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIsolating Switch Amplifier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt;= 1.3 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNAMUR sensor (EN 60947-5-6) or switch contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 V DC \/ 8 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRelay (1 NO contact per channel)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Switching Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e250 V AC \/ 30 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFDT\/DTM software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-20 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-20 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 95% (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.177 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e119.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Pin\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e11, 12\u003c\/td\u003e\n      \u003ctd\u003eChannel 1 Input (NAMUR \/ Switch)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e21, 22\u003c\/td\u003e\n      \u003ctd\u003eChannel 2 Input (NAMUR \/ Switch)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e51, 52\u003c\/td\u003e\n      \u003ctd\u003eChannel 1 Relay Output (NO)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e61, 62\u003c\/td\u003e\n      \u003ctd\u003eChannel 2 Relay Output (NO)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e91, 92\u003c\/td\u003e\n      \u003ctd\u003ePower Supply (19.2 - 31.2 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap-on mounting onto standard TS 35 DIN rails.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use screw terminals with appropriate wire cross-sections. Ensure intrinsic safety separation rules are followed (minimum 50 mm distance between Ex-i and non-Ex-i wiring).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail is properly grounded to maintain signal integrity and safety compliance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain adequate clearance around the module to prevent heat buildup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX\u003c\/li\u003e\n  \u003cli\u003eIECEx\u003c\/li\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102133543275,"sku":"8965340000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965340000-ukfmfon0xxd.png?v=1776137149"},{"product_id":"weidmuller-1504360000-ie-sw-bl05-1gs-4gtpoe-industrial-ethernet-switch","title":"Weidmuller 1504360000 IE-SW-BL05-1GS-4GTPOE Industrial Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding high-speed data transmission and reliable power delivery in demanding environments, the \u003cstrong\u003eWeidmuller 1504360000\u003c\/strong\u003e (Model: \u003cstrong\u003eIE-SW-BL05-1GS-4GTPOE\u003c\/strong\u003e) is an unmanaged Gigabit Ethernet PoE+ switch engineered for industrial automation networks. This robust device features \u003cstrong\u003efour Gigabit RJ45 ports\u003c\/strong\u003e supporting Power over Ethernet Plus (PoE+) and \u003cstrong\u003eone Gigabit SFP slot\u003c\/strong\u003e for long-distance fiber optic uplink connectivity, ensuring seamless integration into modern control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Connectivity:\u003c\/strong\u003e Four 10\/100\/1000BaseT(X) PoE+ ports and one 1000BaseSFP slot for flexible fiber uplinks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower over Ethernet:\u003c\/strong\u003e Delivers up to 30 watts per port under IEEE 802.3at\/af standards, simplifying field device wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Inputs:\u003c\/strong\u003e Dual 12\/24\/48 V DC inputs ensure continuous network operation even during primary power source failures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Construction:\u003c\/strong\u003e Rugged IP30-rated aluminium housing designed for space-constrained DIN-rail installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Data Flow:\u003c\/strong\u003e Store-and-Forward switching technology with an 8 K MAC address table and 1,024 Kbit packet buffer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial manufacturing plants and assembly lines requiring high-bandwidth sensor networks.\u003c\/li\u003e\n  \u003cli\u003eIP-based video surveillance systems (CCTV) in harsh outdoor or factory environments.\u003c\/li\u003e\n  \u003cli\u003ePower utility substations and water\/wastewater treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eTraffic monitoring and intelligent transportation infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eValue \/ Rating\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel \/ Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIE-SW-BL05-1GS-4GTPOE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1504360000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnmanaged PoE+\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePort Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4x RJ45 (10\/100\/1000BaseT(X)), 1x SFP (1000BaseSFP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12 \/ 24 \/ 48 V DC (Redundant dual inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e17.4 A at 24 V DC (0.1 to 1 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1,024 Kbit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eJumbo Frame Support\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUp to 10 KB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMounting Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 degC to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e29 mm x 135 mm x 105 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e360 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 Kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eInterface \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eDescription \u0026amp; Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Supply Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 removable 2-pole terminal blocks for redundant power connections (V1+, V1-, V2+, V2-)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePorts 1 to 4 (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10\/100\/1000BaseT(X) auto-negotiation, Auto-MDI\/MDI-X, PoE+ (IEEE 802.3at\/af) power delivery\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePort 5 (SFP Slot)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1000BaseSFP slot for standard Gigabit SFP fiber transceivers\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eGrounding\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDedicated grounding screw on the metal chassis for EMI shielding\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IE-SW-BL05-1GS-4GTPOE serves as an upgrade path from standard Fast Ethernet switches when transitioning to high-definition IP cameras or gigabit-speed field networks. It is physically compatible with standard Weidmuller DIN-rail mounting brackets. SFP compatibility is open, but using industrial-grade Weidmuller SFP transceivers is recommended to ensure stable optical link budgets under extreme temperatures.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhile the switch supports a wide input range of 12\/24\/48 V DC, the total PoE power budget is highly dependent on the input voltage. To achieve the full IEEE 802.3at PoE+ output (30W per port), a stable 48 V DC power supply is required. Operating at 12 V DC limits the available PoE output power. Additionally, ensure your power supply can handle the high transient inrush current of 17.4 A during startup to prevent system-wide voltage dips.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use shielded twisted-pair (STP) Cat6 or Cat6A cabling when routing PoE lines near high-voltage motor drives or heavy switchgear. Ensure the functional earth terminal on the switch chassis is connected directly to the panel's low-impedance ground bus to protect the internal Ethernet transceivers from electrostatic discharge and electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #9b2c2c;\"\u003eDe-energize all power sources before mounting, wiring, or servicing this device. Do not hot-plug terminal blocks under load. Failure to comply can result in electrical arcing, equipment damage, or personal injury.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eSnap the switch securely onto a standard TS 35 DIN rail, ensuring the metal spring clip locks firmly in place.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eConnect a heavy-gauge copper wire from the chassis ground screw to the main cabinet ground bus.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eWire the redundant power inputs to the 2-pole terminal blocks. Tighten the terminal screws to the specified torque to prevent loose connections.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eInsert the SFP module (if used) into the SFP slot and connect the fiber optic cable. Connect the RJ45 network cables to the PoE+ ports.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102134722923,"sku":"IE-SW-BL05-1GS-4GTPOE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl05-1gs-4gtpoe-bmwn53vrhbn.png?v=1776137747"},{"product_id":"weidmuller-8965410000-act20x-sdi-hdo-h-s-act20x-series-valve-control-module","title":"Weidmuller 8965410000 ACT20X-SDI-HDO-H-S ACT20X Series Valve Control Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOperating as an intrinsically safe solenoid driver, the \u003cstrong\u003eWeidmuller ACT20X-SDI-HDO-H-S\u003c\/strong\u003e controls valve systems, acoustic alarms, and indicators located in hazardous areas. This high-performance module provides galvanic isolation between the control system and the field devices, ensuring reliable signal transmission and robust explosion protection in demanding process environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIntrinsically safe output (Ex ia IIC) designed for direct deployment in hazardous areas.\u003c\/li\u003e\n  \u003cli\u003eIntegrated alarm relay output for immediate signaling of power loss or internal device errors.\u003c\/li\u003e\n  \u003cli\u003eFDT\/DTM software-based configuration for precise parameterization and diagnostic monitoring.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm DIN-rail housing to optimize space within electrical control panels.\u003c\/li\u003e\n  \u003cli\u003eSecure screw connection technology to guarantee long-term, vibration-resistant wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eChemical and petrochemical processing plants with explosive atmospheres (Zone 0, 1, and 2).\u003c\/li\u003e\n  \u003cli\u003eOil and gas extraction, refining, and distribution facilities.\u003c\/li\u003e\n  \u003cli\u003ePneumatic and hydraulic solenoid valve control in hazardous process loops.\u003c\/li\u003e\n  \u003cli\u003eIndustrial signaling, beacon control, and acoustic alarm integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; text-align: left; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; text-align: left; font-weight: bold;\"\u003eTechnical Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e8965410000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eACT20X-SDI-HDO-H-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eValve Control \/ Solenoid Driver\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eNumber of Channels\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eSupply Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e\u0026lt;= 2.5 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eStep Response Time\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e\u0026lt;= 10 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eAlarm Functionality\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eNo supply voltage, Device error\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eAlarm Relay Output\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1 NC contact\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eNominal Switching Voltage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e\u0026lt;= 125 V AC \/ 110 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eContinuous Current (Alarm)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e\u0026lt;= 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eConfiguration Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eFDT\/DTM software\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e0 to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e170 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1.2 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; text-align: left; font-weight: bold;\"\u003eTerminal Block \/ Pin\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; text-align: left; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eTerminals 11, 12\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eDigital Control Input (Safe Area)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eTerminals 13, 14\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eAlarm Relay Output (NC Contact)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eTerminals 41, 42\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eIntrinsically Safe Solenoid Output (Hazardous Area, Ex ia)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px; font-weight: bold;\"\u003eTerminals 51, 52\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePower Supply Input (19.2 to 31.2 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe ACT20X-SDI-HDO-H-S is fully compatible with standard FDT\/DTM frame applications such as Weidmuller WI-Manager. When replacing legacy ACT20X models, ensure that the configuration profile is exported and reloaded using the CBX200 USB interface cable to preserve specific safety loop parameters.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen mounting multiple ACT20X modules side-by-side on a DIN rail, ensure cabinet ventilation maintains ambient temperatures below 60 degC. High-density packing without adequate airflow can lead to localized thermal stress. Always verify that the Ex-i output parameters (Uo, Io, Po) strictly match the electrical characteristics of the connected solenoid valve to maintain safety loop integrity.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePerform offline configuration via the front-panel port before mounting the unit onto the DIN rail. Ensure that intrinsically safe field wiring (hazardous area) is physically separated from non-intrinsically safe wiring (safe area) by a minimum distance of 50 mm, or utilize physical partitions in compliance with IEC\/EN 60079-14 standards.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-weight: bold;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eIsolate all power sources before mounting, wiring, or configuring the device. Failure to de-energize the system prior to installation in hazardous areas can result in electrical arcing, leading to severe equipment damage, explosion, or personal injury.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eMount the module vertically onto a standard TS 35 DIN rail, ensuring secure mechanical latching.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eConnect the intrinsically safe field device wiring to the Ex-designated terminals (Terminals 41 and 42).\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eWire the control input, alarm relay, and the 24 V DC power supply to the safe-area terminals.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1.5rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eConnect the CBX200 USB cable to configure the alarm thresholds and operational parameters via FDT\/DTM software.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102134952299,"sku":"8965410000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965410000-amxmf1n0o4g.png?v=1776137159"},{"product_id":"weidmuller-pro-eco-240w-24v-10a-switch-mode-power-supply","title":"Weidmüller PRO ECO 240W 24V 10A Switch-Mode Power Supply","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-886\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eWeidmüller PRO ECO 240W 24V 10A (Order No. 1469490000)\u003c\/strong\u003e\u003cspan class=\"citation-886 citation-end-886\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency, slimline switch-mode power supply designed for reliable industrial automation performance.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-885 citation-end-885\"\u003eAs part of the PRO ECO series, it balances high power density with essential functionality, making it an economical yet robust solution for machine construction and process industries.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWith a 90% efficiency rating and a compact 60mm metal housing, it is engineered to save space in the control cabinet while minimizing thermal load.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-884 citation-end-884\"\u003eIts versatile input range allows for global use, supporting both AC and DC supply voltages.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-883\"\u003eThe PRO ECO 240W features a high-grade, corrosion-resistant metal housing designed for mounting on a standard\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eTS 35 DIN rail\u003c\/strong\u003e\u003cspan class=\"citation-883 citation-end-883\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt provides a stable 24V DC output, adjustable via a front-facing potentiometer between 22V and 28V to compensate for voltage drops over long cable runs.\u003c\/p\u003e\n\u003cp\u003eOne of its standout features is the comprehensive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree-color LED diagnostic system\u003c\/strong\u003e, which provides immediate visual status of the output health, load levels, and fault conditions. The unit is built for longevity, boasting a Mean Time Between Failures (MTBF) of over 2 million hours (SN 29500 standard).\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-882 citation-end-882\"\u003eIt also supports parallel connection of up to 5 units to increase power capacity or provide redundancy in critical systems.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePRO ECO 240W 24V 10A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1469490000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Adjustable 22–28 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A @ 55 °C (Derating to 2.5 A @ 70 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85...264 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80...370 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 x 125 x 100 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit, Overload, Over-temperature, Reverse voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic LEDs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreen (OK), Yellow (\u0026gt;90% load), Red (Fault\/Overload)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,002 g (Net) \/ 2.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does the Yellow LED indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The Yellow LED is a pre-warning indicator that lights up when the output current exceeds 90% of its rated capacity (typically \u0026gt;9A). This allows maintenance teams to identify potential overloads before the system trips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use this power supply with a DC input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the PRO ECO 240W is a wide-range input device that can operate on 80...370 V DC, making it suitable for specialized battery systems or DC bus applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is a special mounting kit required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No, the unit features an integrated snap-on foot specifically designed for standard TS 35 terminal rails.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the unit is rated for 10A at 55 °C, note that significant derating occurs at higher temperatures. If the cabinet environment reaches 70 °C, the available current drops to 2.5A. Ensure adequate spacing (approx. 50mm vertical clearance) to allow for natural convection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParallel Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting units in parallel (max 5), ensure the output voltages are adjusted as closely as possible to the same value using the potentiometer to ensure balanced load sharing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor safety and protection of the supply line, a 10A Characteristic B or a 3-4A Characteristic C circuit breaker is recommended. The unit contains an internal fuse, but external backup fuses are required by most industrial standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBe aware of the maximum inrush current of 15A. When powering multiple units simultaneously on a single circuit, ensure the upstream breaker is sized to handle the combined peak startup current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe PRO ECO 240W is distinguished by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eActive PFC (Power Factor Correction)\u003c\/strong\u003e, which achieves a power factor of \u0026gt;0.94 at 230V AC, reducing reactive power costs and harmonic distortion.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-881\"\u003eIts\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e20ms bridging time\u003c\/strong\u003e\u003cspan class=\"citation-881 citation-end-881\"\u003e\u003cspan\u003e \u003c\/span\u003eensures that your PLC or sensitive electronics remain powered through minor mains failures or voltage dips.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFurthermore, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emetal housing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides superior electromagnetic compatibility (EMC) and mechanical durability compared to plastic-housed alternatives, making it ideal for the high-vibration and electrically noisy environments found in heavy manufacturing.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102135017835,"sku":"PRO ECO 240W 24V 10A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469490000-fs5fbkxtsu4.png?v=1776137075"},{"product_id":"weidmuller-8965350000-act20x-hdi-sdo-rnc-s-act20x-isolating-switch-amplifier","title":"Weidmuller 8965350000 ACT20X-HDI-SDO-RNC-S ACT20X Isolating Switch Amplifier","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for intrinsically safe signal processing, the \u003cstrong\u003eWeidmuller 8965350000\u003c\/strong\u003e functions as a high-reliability \u003cstrong\u003eisolating switch amplifier\u003c\/strong\u003e within the ACT20X series. This module is engineered to safely isolate and transmit digital signals from hazardous areas (Zone 0, 1, 2) to safe-area control environments. It supports inputs from NAMUR sensors or mechanical switch contacts and converts them into relay outputs.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eACT20X-HDI-SDO-RNC-S\u003c\/strong\u003e features comprehensive galvanic isolation between the input, output, and power supply circuits, ensuring superior signal integrity and system protection. Configuration is managed via standard FDT\/DTM software, allowing operators to easily set parameters, monitor device status, and configure line fault detection (LFD) for open-circuit or short-circuit conditions.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntrinsically safe digital inputs compatible with NAMUR sensors and mechanical switches.\u003c\/li\u003e\n  \u003cli\u003eRelay output configuration for reliable safe-area signal switching.\u003c\/li\u003e\n  \u003cli\u003eGalvanic isolation across input, output, and power supply channels.\u003c\/li\u003e\n  \u003cli\u003eSoftware-based configuration utilizing standard FDT\/DTM tools.\u003c\/li\u003e\n  \u003cli\u003eIntegrated line fault detection (LFD) to identify open and short circuits in the field wiring.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm housing designed for standard DIN-rail mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas processing and refining facilities.\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical manufacturing plants.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment systems.\u003c\/li\u003e\n  \u003cli\u003ePower generation and distribution utilities.\u003c\/li\u003e\n  \u003cli\u003eHazardous area signal isolation and safety instrumented systems (SIS).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003e8965350000 (ACT20X-HDI-SDO-RNC-S)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Series\u003c\/strong\u003e\n      \u003ctd\u003eACT20X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Type\u003c\/strong\u003e\n      \u003ctd\u003eNAMUR sensor (DIN EN 60947-5-6), switch contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSensor Supply\u003c\/strong\u003e\n      \u003ctd\u003e8 V DC \/ 8 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOutput Type\u003c\/strong\u003e\n      \u003ctd\u003eRelay\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNominal Switching Voltage\u003c\/strong\u003e\n      \u003ctd\u003e\u0026lt;= 125 V AC \/ 110 V DC (safe area), \u0026lt;= 32 V AC \/ 32 V DC (Zone 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\n      \u003ctd\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Consumption\u003c\/strong\u003e\n      \u003ctd\u003e\u0026lt;= 1.3 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\n      \u003ctd\u003eFDT\/DTM software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConnection Type\u003c\/strong\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eIP Rating\u003c\/strong\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-20 to +60 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-20 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHumidity\u003c\/strong\u003e\n      \u003ctd\u003e0 to 95% (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\n      \u003ctd\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e175 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap securely onto a standard TS 35 DIN rail in a vertical orientation to optimize heat dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Maintain a minimum physical distance of 50 mm between intrinsically safe (Ex i) field wiring and non-intrinsically safe wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail is properly bonded to the functional earth ground of the control cabinet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Protection:\u003c\/strong\u003e For installation in Zone 2 environments, the module must be mounted inside an enclosure providing a minimum protection rating of IP54.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX\u003c\/li\u003e\n  \u003cli\u003eIECEx\u003c\/li\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102135050603,"sku":"8965350000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965350000-cqa1mp3x32j.png?v=1776137149"},{"product_id":"weidmuller-ie-sw-bl06-4poe-2sc-basicline-unmanaged-poe-fast-ethernet-switch","title":"Weidmuller IE-SW-BL06-4POE-2SC BasicLine Unmanaged PoE+ Fast Ethernet Switch","description":"\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eProviding reliable power and data transmission in demanding industrial environments, the Weidmuller \u003cstrong\u003eIE-SW-BL06-4POE-2SC\u003c\/strong\u003e (Article Number \u003cstrong\u003e1504210000\u003c\/strong\u003e) is an industrial-grade, unmanaged Fast Ethernet PoE+ switch. This device is equipped with four 10\/100BaseT(X) Power-over-Ethernet (PoE+) ports and two 100BaseFX multimode fiber optic ports with SC-Duplex connectors, enabling long-distance network extensions up to 5 km.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for seamless integration into factory automation and process control networks, this switch utilizes a store-and-forward switching architecture with a 1 K MAC address table and a 512 kBit packet buffer to ensure stable data transmission. The hardware is housed in a rugged IP30-rated aluminum enclosure and features redundant dual 24\/48 V DC power inputs to maximize system uptime in critical applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEquipped with 4 Fast Ethernet ports supporting PoE+ (IEEE 802.3at\/af) and 2 Multimode SC-Duplex fiber ports.\u003c\/li\u003e\n  \u003cli\u003eSupports typical fiber optic transmission distances up to 5 km.\u003c\/li\u003e\n  \u003cli\u003eRedundant dual 24\/48 V DC power inputs to prevent network downtime.\u003c\/li\u003e\n  \u003cli\u003eStore-and-forward data switching mechanism for optimized packet delivery.\u003c\/li\u003e\n  \u003cli\u003eRugged IP30 aluminum housing designed for space-saving DIN-rail or panel mounting.\u003c\/li\u003e\n  \u003cli\u003ePassive cooling design with an operating temperature range of 0 degC to 60 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial IP video surveillance and security systems.\u003c\/li\u003e\n  \u003cli\u003eFactory automation, machine-to-machine (M2M) communication, and field device integration.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility monitoring.\u003c\/li\u003e\n  \u003cli\u003ePower distribution, smart grid monitoring, and substation automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eIE-SW-BL06-4POE-2SC (1504210000)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSwitch Type\u003c\/strong\u003e\n      \u003ctd\u003eUnmanaged PoE+\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\n      \u003ctd\u003e100 Mbps (Fast Ethernet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eData Switching\u003c\/strong\u003e\n      \u003ctd\u003eStore and Forward\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMAC Table Size\u003c\/strong\u003e\n      \u003ctd\u003e1 K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePacket Buffer Size\u003c\/strong\u003e\n      \u003ctd\u003e512 kBit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eFiber Transceiver Type\u003c\/strong\u003e\n      \u003ctd\u003eMultimode\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConnector Type\u003c\/strong\u003e\n      \u003ctd\u003eSC-Duplex\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTransmission Distance (Typical)\u003c\/strong\u003e\n      \u003ctd\u003e5 km\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eVoltage Supply\u003c\/strong\u003e\n      \u003ctd\u003e24\/48 V DC, 2 redundant inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\n      \u003ctd\u003e5.5 A at 24 V DC (full PoE+ load), 2.6 A at 48 V DC (full PoE+ load)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConnection Type\u003c\/strong\u003e\n      \u003ctd\u003e1 removable 4-pin terminal block\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHousing Material\u003c\/strong\u003e\n      \u003ctd\u003eAluminium\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProtection Degree\u003c\/strong\u003e\n      \u003ctd\u003eIP30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMounting Type\u003c\/strong\u003e\n      \u003ctd\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n      \u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHumidity\u003c\/strong\u003e\n      \u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWidth\u003c\/strong\u003e\n      \u003ctd\u003e50 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHeight\u003c\/strong\u003e\n      \u003ctd\u003e115 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDepth\u003c\/strong\u003e\n      \u003ctd\u003e70 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNet Weight\u003c\/strong\u003e\n      \u003ctd\u003e375 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\/Port\u003c\/th\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eSpecification \/ Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePorts 1 to 4\u003c\/td\u003e\n      \u003ctd\u003eRJ45\u003c\/td\u003e\n      \u003ctd\u003e10\/100BaseT(X), PoE+ (IEEE 802.3at\/af)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePorts 5 and 6\u003c\/td\u003e\n      \u003ctd\u003eSC-Duplex\u003c\/td\u003e\n      \u003ctd\u003e100BaseFX, Multimode fiber optic, up to 5 km\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Input\u003c\/td\u003e\n      \u003ctd\u003e4-pin terminal block\u003c\/td\u003e\n      \u003ctd\u003eRemovable, redundant dual V+ \/ V- inputs and ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe switch is designed for mounting on a standard 35 mm DIN rail. Ensure the DIN rail is securely grounded to the protective earth (PE) system before mounting the device. For optimal thermal performance, maintain at least 20 mm of clearance on all sides of the housing to allow natural convection cooling.\u003c\/p\u003e\n\u003cp\u003eWhen wiring the redundant power inputs, use the provided 4-pin removable terminal block. Ensure that the power supply cables are rated for the maximum current consumption of 5.5 A at 24 V DC. Tighten the terminal block screws to the specified torque to prevent loose connections in high-vibration environments.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102135345515,"sku":"IE-SW-BL06-4POE-2SC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06-4poe-2sc-030hiqacxkd.png?v=1776137754"},{"product_id":"weidmuller-8965470000-act20x-hti-sao-s-temperature-transducer","title":"Weidmuller 8965470000 ACT20X-HTI-SAO-S Temperature Transducer","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing temperature signals from hazardous areas requires high-integrity isolation, which is precisely what the \u003cstrong\u003eWeidmuller ACT20X-HTI-SAO-S\u003c\/strong\u003e (Article Number \u003cstrong\u003e8965470000\u003c\/strong\u003e) delivers. This intrinsically safe temperature transducer converts RTD and thermocouple inputs into a standard isolated analog current signal, ensuring safe and accurate data transmission to the control system. Designed for DIN-rail mounting, it integrates seamlessly into modern process automation architectures.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eIntrinsically safe input designed for Zone 0 \/ Division 1 hazardous area deployments.\u003c\/li\u003e\n  \u003cli\u003eFDT\/DTM software-based configuration for precise calibration and parameterization.\u003c\/li\u003e\n  \u003cli\u003eIntegrated alarm relay output for line interruption, short circuit, and device errors.\u003c\/li\u003e\n  \u003cli\u003eHigh galvanic isolation between input, output, and power supply circuits.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm housing width to maximize control cabinet density.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eChemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eOil and gas extraction and refining facilities.\u003c\/li\u003e\n  \u003cli\u003ePower generation thermal monitoring.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8965470000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eACT20X-HTI-SAO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 0.8 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTemperature (RTD, Thermocouple)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOutput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eActive current (analog)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAlarm Function\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLine interruption, short circuit, no supply voltage, device error\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNominal Switching Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 125 V AC \/ 110 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eContinuous Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStep Response Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 400 ms (with current), \u0026lt;= 1 s (with temperature)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Technology\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.178 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.2 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eTerminal \/ Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e41 - 44\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSensor Input (RTD \/ Thermocouple \/ Resistance)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e11 - 12\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAnalog Output (Active Current)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e13 - 14\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDevice Power Supply (19.2...31.2 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e51 - 52\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAlarm Relay Output\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe ACT20X-HTI-SAO-S is part of Weidmuller's specialized intrinsically safe signal converter family. It requires the WI-Manager software (FDT frame) and the specific ACT20X DTM driver package for configuration. Ensure your USB interface cable (such as the Weidmuller CBX200) is compatible before attempting setup.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen mounting multiple ACT20X modules side-by-side on a DIN rail, ensure adequate cabinet ventilation. Although the power consumption is low (\u0026lt;= 0.8 W), high ambient temperatures exceeding 60 degC can degrade the internal optocouplers over long-term operation. Always verify that the Ex-protection parameters (Uo, Io, Po) match the connected field sensor's entity parameters.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor thermocouple inputs, ensure the cold junction compensation (CJC) is correctly configured in the DTM software. If using RTDs, 3-wire or 4-wire configurations are highly recommended over 2-wire setups to eliminate lead resistance errors. Shielded cabling must be grounded only at the designated safe-area ground point to prevent ground loops.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e \u003cspan style=\"color: #9b2c2c;\"\u003eDe-energize all power sources before mounting, wiring, or configuring the device. Ensure the installation complies with all local and international intrinsic safety regulations (Ex-protection). Do not connect non-intrinsically safe signals to the blue Ex-input terminals.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the device vertically on a standard TS 35 DIN rail.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the temperature sensor to the blue Ex-input terminals (41-44) following the sensor-specific wiring diagram.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the analog output (11-12), power supply (13-14), and alarm relay (51-52) to the safe-area terminals.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eApply power and connect via the front-panel interface to configure sensor type and scaling parameters using FDT\/DTM software.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102135869803,"sku":"8965470000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965470000-b3knlsmswhu.png?v=1776137166"},{"product_id":"8965430000-weidmuller-act20x-hai-sao-s-hart-protocol-transparent-current-supply-isolators","title":"8965430000 | Weidmuller | ACT20X-HAI-SAO-S HART-Protocol Transparent Current-Supply Isolators","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eWeidmuller 8965430000 (ACT20X-HAI-SAO-S)\u003c\/strong\u003e\u003cspan\u003e is a precision-engineered single-channel HART-protocol transparent current-supply isolator.\u003c\/span\u003e\u003cspan\u003e Designed for critical signal conditioning in hazardous areas,\u003c\/span\u003e\u003cspan\u003e this module provides an essential barrier between 4 to 20 mA field transmitters and the control system (DCS\/PLC).\u003c\/span\u003e\u003cspan\u003e The \u003c\/span\u003e\u003cstrong\u003e8965430000\u003c\/strong\u003e\u003cspan\u003e specializes in \"HART transparency,\u003c\/span\u003e\u003cspan\u003e\" allowing digital diagnostic and configuration data to pass through the analog loop without interference.\u003c\/span\u003e\u003cspan\u003e By utilizing galvanic isolation,\u003c\/span\u003e\u003cspan\u003e it eliminates ground loops and protects the control infrastructure from electrical transients.\u003c\/span\u003e\u003cspan\u003e Its ultra-high accuracy (\u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e\u0026lt; 0.1%\u003c\/span\u003e\u003cspan\u003e span) and rapid 5 ms response time make it a standard choice for high-availability process plants,\u003c\/span\u003e\u003cspan\u003e including refineries and chemical processing facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ACT20X-HAI-SAO-S is a high-performance single-channel variant within the ACT20X family,\u003c\/span\u003e\u003cspan\u003e housed in a space-efficient 22.\u003c\/span\u003e\u003cspan\u003e5 mm DIN-rail mounting enclosure.\u003c\/span\u003e\u003cspan\u003e It features a versatile voltage supply range (19.\u003c\/span\u003e\u003cspan\u003e2 to 31.\u003c\/span\u003e\u003cspan\u003e2 VDC) and utilizes screw connections for secure,\u003c\/span\u003e\u003cspan\u003e vibration-resistant wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike basic isolators,\u003c\/span\u003e\u003cspan\u003e this unit is fully software-configurable via the FDT\/DTM interface.\u003c\/span\u003e\u003cspan\u003e This allows engineers to monitor and set alarm thresholds for four specific fault conditions:\u003c\/span\u003e\u003cspan\u003e signal limit violations,\u003c\/span\u003e\u003cspan\u003e input line interruptions,\u003c\/span\u003e\u003cspan\u003e loss of supply voltage,\u003c\/span\u003e\u003cspan\u003e and internal device errors.\u003c\/span\u003e\u003cspan\u003e The integrated relay output provides a hardwired alarm contact capable of switching up to 125 VAC,\u003c\/span\u003e\u003cspan\u003e ensuring that critical faults are communicated to the safety system even if the primary analog signal is compromised.\u003c\/span\u003e\u003cspan\u003e Its low power consumption (\u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e\u0026lt;= 1.0 W\u003c\/span\u003e\u003cspan\u003e) reduces the heat load within crowded marshalling cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACT20X-HAI-SAO-S (8965430000)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWeidmuller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-Channel (Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput\/Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA (HART Transparent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 0.1% of span\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStep Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 5 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 125 VAC \/ 110 VDC (Relay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 1.0 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 0.01% of span \/ deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFDT\/DTM Software\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e117.2 x 22.5 x 113.6 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.186 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the benefit of the 5 ms step response time in this isolator?\u003c\/strong\u003e\u003cspan\u003eA1:\u003c\/span\u003e\u003cspan\u003e A 5 ms response time ensures that the isolator adds negligible delay to the control loop.\u003c\/span\u003e\u003cspan\u003e This is critical for high-speed pressure or flow control applications where even millisecond delays can lead to process instability or oscillations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does HART transparency assist with maintenance?\u003c\/strong\u003e\u003cspan\u003eA2:\u003c\/span\u003e\u003cspan\u003e It allows technicians to use a HART handheld communicator or asset management software (like AMS or PRM) to calibrate field transmitters directly through the isolator.\u003c\/span\u003e\u003cspan\u003e You do not need to bypass the module to access the transmitter's digital data.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the alarm relay be used for more than just \"Line Interruption\"?\u003c\/strong\u003e\u003cspan\u003eA3:\u003c\/span\u003e\u003cspan\u003e Yes.\u003c\/span\u003e\u003cspan\u003e Through the FDT\/DTM software,\u003c\/span\u003e\u003cspan\u003e you can configure the relay to trigger based on \"Signal limit exceeded\" (e.\u003c\/span\u003e\u003cspan\u003eg.,\u003c\/span\u003e\u003cspan\u003e if the mA goes above 21 mA or below 3.\u003c\/span\u003e\u003cspan\u003e8 mA),\u003c\/span\u003e\u003cspan\u003e as well as internal device errors or power loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Loop Resistance:\u003c\/strong\u003e\u003cspan\u003e Ensure that the total loop resistance (including the transmitter,\u003c\/span\u003e\u003cspan\u003e field wiring,\u003c\/span\u003e\u003cspan\u003e and the isolator's internal resistance) remains within the transmitter's driving capacity.\u003c\/span\u003e\u003cspan\u003e A 250 Ohm resistor is typically required for HART communication,\u003c\/span\u003e\u003cspan\u003e and the ACT20X-HAI-SAO-S is designed to accommodate this while maintaining signal integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003cspan\u003e For maximum accuracy (\u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e\u0026lt; 0.1%\u003c\/span\u003e\u003cspan\u003e span),\u003c\/span\u003e\u003cspan\u003e use twisted-pair shielded cables for the 4 to 20 mA signal.\u003c\/span\u003e\u003cspan\u003e Connect the shield at a single point (usually the DCS cabinet earth) to prevent ground loops that could induce noise into the high-precision analog measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware and DTM Sync:\u003c\/strong\u003e\u003cspan\u003e Always use the latest DTM (Device Type Manager) version from Weidmuller's WI-Manager suite when configuring the 8965430000.\u003c\/span\u003e\u003cspan\u003e This ensures that all diagnostic features and alarm parameters are correctly mapped and accessible during commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe 8965430000 is distinguished by its exceptional thermal stability (\u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e\u0026lt; 0.01% \u003c\/span\u003e\u003cspan\u003eof span per deg C),\u003c\/span\u003e\u003cspan\u003e making it ideal for cabinets located in non-climate-controlled environments.\u003c\/span\u003e\u003cspan\u003e Its single-channel design offers modularity; a single loop failure or maintenance requirement only affects one process variable,\u003c\/span\u003e\u003cspan\u003e enhancing the overall \"Fault Tolerance\" of the I\/O node.\u003c\/span\u003e\u003cspan\u003e Furthermore,\u003c\/span\u003e\u003cspan\u003e the 1.\u003c\/span\u003e\u003cspan\u003e0W low-power architecture significantly extends the MTBF (Mean Time Between Failures) of the device by minimizing internal component stress caused by heat,\u003c\/span\u003e\u003cspan\u003e which is a primary concern in 24\/7 continuous process industries.\u003c\/span\u003e\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102136099179,"sku":"8965430000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965430000-w3mfpsg0czs.png?v=1776137161"},{"product_id":"weidmuller-1504390000-ie-sw-vl05mt-3tx-2st-managed-industrial-ethernet-switch","title":"Weidmuller 1504390000 (IE-SW-VL05MT-3TX-2ST) Managed Industrial Ethernet Switch","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWeidmuller 1504390000 (IE-SW-VL05MT-3TX-2ST)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, managed Industrial Ethernet switch engineered for robust data distribution in extreme environments. Part of the Value Line series, this switch features a versatile port configuration consisting of three 10\/100BaseT(X) copper ports and two 100BaseFX multimode fiber ports with ST-Duplex connectors.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-79\"\u003eDesigned for mission-critical applications in wind power, smart grids, and heavy manufacturing, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e1504390000\u003c\/strong\u003e\u003cspan class=\"citation-79 citation-end-79\"\u003e\u003cspan\u003e \u003c\/span\u003esupports advanced management features such as Ring redundancy and VLANs to ensure maximum network availability.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIts wide operating temperature range (-40 to 75 deg C) and metal IP30 housing make it a reliable choice for decentralized control cabinets where environmental stability cannot be guaranteed.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe IE-SW-VL05MT-3TX-2ST utilizes a \"Store and Forward\" data switching architecture, ensuring that only valid, error-free packets are transmitted across the network.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-78 citation-end-78\"\u003eWith a 2 K MAC address table and a 1 Mbit packet buffer, it efficiently manages localized traffic without congestion.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe integration of two ST-Duplex multimode fiber ports allows for reliable long-distance transmission up to 5 km, effectively bypassing electromagnetic interference (EMI) that typically degrades copper-based signals in motor control centers.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-77 citation-end-77\"\u003eFor power reliability, the switch is equipped with a removable 6-pin terminal block supporting redundant 12\/24\/48 VDC inputs.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis redundancy ensures that the network remains active even if one power circuit fails. The managed firmware provides industrial-grade features including IGMP snooping, port-based VLANs, and various ring protocols for sub-20ms recovery times in the event of a network loop break.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIE-SW-VL05MT-3TX-2ST (1504390000)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWeidmuller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitch Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManaged Industrial Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Ports (3x RJ45, 2x ST-Fiber)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbps (Fast Ethernet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultimode (ST-Duplex)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Dist\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 km (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Redundant DC Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 75 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMetal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e135 x 53.6 x 105 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e650 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What are the benefits of the ST-Duplex fiber connectors over standard RJ45?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The ST-Duplex fiber interface provides two major advantages: it extends the transmission distance to 5 km (compared to 100 m for copper) and provides total immunity to electrical noise (EMI\/RFI), which is critical when routing cables near high-voltage VFDs or motors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this switch support ring redundancy for high availability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-76 citation-end-76\"\u003eAs a managed switch in the Value Line, it supports various redundancy protocols, allowing the network to recover in less than 20 ms if a segment of the fiber or copper ring is damaged.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this module be mounted in outdoor cabinets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: While the switch has an impressive operating range of -40 to 75 deg C, it is rated IP30. This means it must be installed inside a secondary NEMA 4 or IP66 rated enclosure if it is to be used in outdoor or wash-down environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiber Optic Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting the ST-Duplex transceivers, ensure the fiber end-faces are cleaned with an approved optical grade cleaner. Dust on a 100 Mbps fiber port can lead to significant packet loss or a complete link failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Power Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the 6-pin removable terminal block to connect two independent power sources (e.g., a primary PSU and a battery backup). Ensure the grounding pin is connected to the DIN rail or cabinet earth to provide a path for transient surge protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Segmenting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the managed VLAN features to isolate sensitive PLC\/DCS traffic from general peripheral data. This reduces the broadcast traffic processed by the 2 K MAC table and ensures lower latency for critical control packets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1504390000 is distinguished by its extreme thermal resilience, maintaining full 100 Mbps throughput at 75 deg C without the need for active cooling fans. Its \"Store and Forward\" switching method is specifically calibrated for industrial protocols (like PROFINET or EtherNet\/IP), prioritizing data integrity over raw cut-through speed.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-75 citation-end-75\"\u003eFurthermore, the compact 53.6 mm width allows for significant port density on crowded DIN rails, while the metal housing provides the structural rigidity required for high-vibration applications such as rail transport or heavy stamping presses.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102137999723,"sku":"IE-SW-VL05MT-3TX-2ST","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-vl05mt-3tx-2st-fg3ckr0f1s4.png?v=1776137766"},{"product_id":"weidmuller-8965400000-act20x-sdi-hdo-l-s-intrinsic-safety-valve-driver","title":"Weidmuller 8965400000 ACT20X-SDI-HDO-L-S Intrinsic Safety Valve Driver","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-64\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eWeidmuller 8965400000 (ACT20X-SDI-HDO-L-S)\u003c\/strong\u003e\u003cspan class=\"citation-64 citation-end-64\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized solenoid driver module designed to control intrinsically safe (IS) valves and indicators located in hazardous areas.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAs a critical component of the ACT20X signal conditioner family, it serves as an isolator between safe-area control signals and Ex-zone field devices. Engineered for high-reliability process environments like chemical dosing and fuel storage, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8965400000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts digital control signals from a PLC or DCS into the energy-limited power required to actuate solenoid valves in ATEX\/IECEx Zones 0, 1, or 2. Its integrated alarm relay and software-programmable parameters ensure that valve failures or supply losses are instantly reported, minimizing process risk and protecting expensive field assets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe ACT20X-SDI-HDO-L-S features a single-channel, high-current output (HDO) architecture optimized for \"L\" (Low) power solenoid coils.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-63 citation-end-63\"\u003eIt provides galvanic 3-way isolation between the input, output, and power supply, ensuring that electrical faults in the hazardous area cannot reach the control cabinet backplane.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-62 citation-end-62\"\u003eConfiguration is handled through the standardized FDT\/DTM software interface, allowing engineers to set precise current limits and define the behavior of the alarm relay.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe unit monitors for \"No Supply Voltage\" and internal \"Device Error\" conditions, triggering a change-over in the nominal switching relay (up to 125 VAC) to notify the supervisory system.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-61 citation-end-61\"\u003eIts 10 ms step response time ensures rapid valve actuation for time-critical safety sequences, while the 22.5 mm slim housing facilitates high-density DIN-rail mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACT20X-SDI-HDO-L-S (8965400000)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWeidmuller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValve Control \/ Solenoid Driver\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Current (HDO), Low Power (L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStep Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.2 to 31.2 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 1.9 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo supply voltage, Device error\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 125 VAC \/ 110 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital (Switching)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e117.2 x 22.5 x 113.6 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.170 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does the \"L\" signify in the HDO-L-S suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The \"L\" indicates a Low-power output characteristic. This module is specifically tuned to drive intrinsically safe solenoids that require lower holding currents while maintaining sufficient voltage to ensure reliable actuation in hazardous zones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I configure this module without specialized hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: You need the Weidmuller USB interface cable and a PC with FDT\/DTM software (WI-Manager). This software-based configuration allows you to verify internal diagnostics and set custom alarm conditions that are not possible with hardware DIP switches.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is the alarm relay output \"Fail-Safe\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. The alarm relay is typically configured to de-energize (open contact) upon a loss of supply voltage or a device error, ensuring that the control system detects a fault even if the module loses power entirely.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntrinsic Safety Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the \"Entity Parameters\" (\u003cspan class=\"math-inline\"\u003e$U_o, I_o, P_o$\u003c\/span\u003e) of the 8965400000 match or exceed the requirements of your solenoid valve. The total inductance and capacitance of the field wiring must be calculated to remain within the ATEX\/IECEx limits for the specific zone of installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor the screw connections, use a calibrated screwdriver to apply the manufacturer's recommended torque. Loose connections in valve control circuits are a leading cause of \"Device Error\" alarms due to increased contact resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Ventilation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting several ACT20X modules side-by-side, allow for sufficient natural convection. While the module is rated for 0-95% humidity, a dry, dust-free environment will significantly extend the lifespan of the internal isolation transformers and switching relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-60 citation-end-60\"\u003eThe 8965400000 is distinguished by its 3-way isolation and 10 ms response time, making it an ideal choice for Emergency Shutdown (ESD) applications.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIts software-centric configuration allows for \"digital fingerprinting\" of the device setup, making it easy for maintenance teams to replicate settings across multiple units during plant expansions. Furthermore, the inclusion of a high-voltage switching relay (\u003cspan class=\"math-inline\"\u003e125 VAC\u003c\/span\u003e) allows this module to directly interface with legacy 110V alarm systems, eliminating the need for interposing relays and simplifying the overall control cabinet bill of materials.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102138360171,"sku":"ACT20X-SDI-HDO-L-S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965400000-jh3rntmugs0.png?v=1776137158"},{"product_id":"8965440000-weidmuller-act20x-2hai-2sao-s-hart-transparent-isolator","title":"8965440000 Weidmuller ACT20X-2HAI-2SAO-S HART Transparent Isolator","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-47\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eWeidmuller 8965440000 (ACT20X-2HAI-2SAO-S)\u003c\/strong\u003e\u003cspan class=\"citation-47 citation-end-47\"\u003e\u003cspan\u003e \u003c\/span\u003eis a sophisticated 2-channel HART-protocol transparent current-supply isolator designed for hazardous area applications.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePart of the ACT20X series, this module provides signal isolation and conditioning for 4 to 20 mA loops while maintaining full transparency for bidirectional HART communication. Engineered for high-stakes environments such as chemical processing and offshore platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8965440000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeffectively decouples field devices from the control system, eliminating ground loops and protecting sensitive DCS\/PLC inputs from high-voltage transients. Its primary value lies in its high accuracy (\u003cspan class=\"math-inline\"\u003e\u003c\/span\u003e\u0026lt; 0.1% Span) and integrated alarm functions, which proactively monitor for line interruptions and device errors to maximize process availability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe ACT20X-2HAI-2SAO-S is a dual-channel powerhouse housed in a slim 22.5 mm enclosure, saving significant DIN-rail space.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-46 citation-end-46\"\u003eIt operates on a wide supply voltage range of 19.2 to 31.2 VDC and is fully configurable via FDT\/DTM software, allowing for precise adjustment of signal limits and alarm thresholds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOne of its standout features is \"HART Transparency,\" which ensures that digital diagnostic data from smart transmitters can pass through the isolator without distortion.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-45 citation-end-45\"\u003eThe module also features a dedicated relay alarm output for collective error messaging.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt monitors for four distinct fault conditions: signal limit violations, input line interruptions, supply voltage loss, and internal device errors. The screw connection system provides high mechanical stability, ensuring reliable electrical contact even in high-vibration industrial settings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACT20X-2HAI-2SAO-S (8965440000)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWeidmuller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-Channel (Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput\/Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA (HART Transparent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 0.1% of span\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStep Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 5 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 125 VAC \/ 110 VDC (Relay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 1.9 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFDT\/DTM Software\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e117.2 x 22.5 x 113.6 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.212 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does \"HART Transparent\" mean for this isolator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: It means the module does not strip away the high-frequency digital signal superimposed on the 4 to 20 mA analog loop. This allows your DCS or handheld communicator to \"see\" and configure smart field devices through the isolator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How do the alarm functions improve plant safety?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The module features a physical relay contact that opens or closes when a fault occurs (like a broken wire). This provides an immediate hardware-level notification to the safety system, independent of the analog signal value.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the ACT20X-2HAI-2SAO-S be installed directly in ATEX Zone 0?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The module itself must be installed in a safe area or Zone 2, but it is designed to interface with intrinsic safety (IS) signals coming from Zone 0, 1, or 2. Always check the specific Ex-certification markings on the device housing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-44\"\u003e\u003c\/span\u003e\u003cstrong\u003eSoftware Configuration:\u003c\/strong\u003e\u003cspan class=\"citation-44 citation-end-44\"\u003e\u003cspan\u003e \u003c\/span\u003eUse the Weidmuller WI-Manager (FDT frame) and the specific DTM for ACT20X to set up the device.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis allows you to define \"Active\" or \"Passive\" input modes and configure the fail-safe behavior of the relay output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the module is rated up to 60 deg C, maintain a 5 mm gap between adjacent high-power modules if the ambient temperature in the cabinet consistently exceeds 45 deg C. This prevents the internal \"Step response time\" from drifting due to thermal stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor HART communication integrity, ensure that the total loop impedance (including the 250 Ohm resistor) does not exceed the module's driving capability. Use shielded twisted-pair cables for the 4 to 20 mA loops to maintain the \u0026lt; 0.1% accuracy in high EMI environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-43 citation-end-43\"\u003eThe ACT20X-2HAI-2SAO-S is distinguished by its extremely low temperature coefficient (\u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e\u0026lt; 0.01% \u003c\/span\u003e\u003cspan class=\"citation-42 citation-end-42\"\u003eof span per deg C), ensuring that signal measurements remain precise regardless of seasonal temperature swings in the control room.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-41 citation-end-41\"\u003eIts rapid 5 ms response time makes it suitable for fast-acting control loops and safety-instrumented systems (SIS).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFurthermore, the 2-channel design provides a 50% reduction in DIN-rail footprint compared to standard single-channel isolators, making it the ideal choice for high-density marshalling cabinets in modernized plant architectures.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102138589547,"sku":"ACT20X-2HAI-2SAO-S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965440000-ngibj2i2kgn.png?v=1776137163"},{"product_id":"1504430000-weidmuller-ie-dinrailmount-kit","title":"1504430000 Weidmuller IE-DINRAILMOUNT-KIT","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIE-DINRAILMOUNT-KIT (1504430000)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized hardware accessory designed by Weidmuller to provide flexible installation options for industrial communication devices. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMounting Kit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically engineered for the alternative fixing of Weidmüller’s serial converters and fiber-optic cable converters onto standard TS 35 DIN rails. In complex control cabinets where space optimization is critical, this kit allows engineers to transition from traditional wall or panel mounting to a standardized DIN rail configuration, ensuring a clean, organized, and vibration-resistant installation of critical networking hardware.\u003c\/p\u003e\n\u003ch3\u003eFunctional Engineering \u0026amp; Design\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1504430000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ekit is characterized by its ultra-lightweight yet robust design, with a net weight of only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9 g\u003c\/strong\u003e. Despite its small footprint, it provides a high-strength mechanical bond between the converter housing and the rail. The kit is designed for rapid deployment, allowing for \"snap-on\" functionality that significantly reduces assembly time during cabinet builds. By standardizing the mounting profile of serial and fiber-optic media converters, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIE-DINRAILMOUNT-KIT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that signal conversion components are aligned with other PLC and I\/O modules, facilitating better cable routing and maintenance access.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1504430000\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWeidmuller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIE-DINRAILMOUNT-KIT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWeidmüller Serial\/Fiber-Optic Converters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Version\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTS 35 DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS Conform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Grade Plastic\/Metal (Standard Weidmuller spec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich specific Weidmuller devices are compatible with this kit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1504430000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily designed for the Weidmuller IE-Line, including various RS232\/485 serial converters and Ethernet-to-Fiber optic media converters that do not come with a pre-installed DIN rail clip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this kit support both TS 35 and TS 32 rails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis kit is optimized for the standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTS 35 (Top Hat)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail. For legacy TS 32 (G-rail) installations, an additional adapter or a different mounting series may be required, as the clip mechanism is tailored for the 35 mm profile.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the kit resistant to high-vibration industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIE-DINRAILMOUNT-KIT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for industrial use. Once snapped onto the rail, it provides a secure fit that prevents the converter from sliding or detaching due to the mechanical vibrations typically found in motor control centers or manufacturing floors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrect Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore tightening the screws that attach the kit to the converter, ensure the clip is oriented so that the tension spring faces downward. This allows for easier removal using a standard flat-head screwdriver if the device needs to be relocated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse precision tools to attach the bracket to the converter housing. Over-tightening the small mounting screws can strip the threads of the plastic housing, while under-tightening may lead to mechanical instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpacing Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the kit is compact, always allow for the minimum bend radius of the fiber-optic or serial cables connected to the converter. Avoid mounting the kit too close to wire ducts that might put lateral stress on the mounting clip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWeidmuller 1504430000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers a low-cost, high-impact solution for system integrators. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9 g\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eweight ensures it adds negligible load to the rail, while its RoHS compliance guarantees it meets modern environmental standards for global export. The kit's simplicity is its greatest engineering strength—providing a tool-less snap-on interface for the DIN rail while maintaining the rigid structural integrity required for long-term industrial service. It is an essential component for any B2B project involving the modernization of serial or fiber-optic network infrastructure.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102139539819,"sku":"IE-DINRAILMOUNT-KIT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-dinrailmount-kit-uqyn2dsuxtx.png?v=1776137741"}],"url":"https:\/\/www.plcprotech.com\/pl\/collections\/weidmuller.oembed?page=3","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}