{"product_id":"138607-01-bently-nevada-3500-22m-standard-transient-data-interface-module","title":"138607-01 | Bently Nevada | 3500\/22M Standard Transient Data Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/22M 138607-01\u003c\/strong\u003e serves as the primary communication and data acquisition gateway within the 3500 machinery protection framework. This system components combination interfaces between the monitoring rack and specialized engineering platforms, including System 1 Condition Monitoring software alongside the 3500 Configuration toolsets. It functions as a complete replacement solution that merges standard Rack Interface Module (RIM) operations with advanced transient dynamic data collection capabilities. The module processes steady-state variables, synchronous\/asynchronous waveforms, and detailed alarm captures via dual Ethernet protocol lines. Integrated directly into the slot adjacent to the system power modules, it ensures reliable automated diagnostic access without influencing the autonomous machine trip paths built into core monitor hardware.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated interface solution combining Rack Interface Module functions with high-density communication processor capabilities.\u003c\/li\u003e\n\u003cli\u003eContinuous dynamic and static variable extraction across up to 48 monitoring channels simultaneously.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution synchronous and asynchronous waveform sampling rates with software-selectable resolutions.\u003c\/li\u003e\n\u003cli\u003eSupport for four independent Keyphasor tachometer signals over a wide rotational speed range.\u003c\/li\u003e\n\u003cli\u003eSpecialized transient dynamic data capture mapped directly to machine startup and coastdown event thresholds.\u003c\/li\u003e\n\u003cli\u003eComprehensive pre-alarm and post-alarm historical tracking buffers retaining continuous sub-second data.\u003c\/li\u003e\n\u003cli\u003eSelectable network options featuring dual autosensing copper interfaces or dedicated fiber optic configurations.\u003c\/li\u003e\n\u003cli\u003eFront-panel operational keylock mechanism providing physical hardware configuration lockout protection.\u003c\/li\u003e\n\u003cli\u003eIntegrated software utilities for in-system address programming supporting up to 127 individual racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed transient vibration mapping and diagnostic tracking on critical turbomachinery installations.\u003c\/li\u003e\n\u003cli\u003eContinuous online condition monitoring across automated power generation and petrochemical process cells.\u003c\/li\u003e\n\u003cli\u003eReal-time dynamic spectrum extraction and synchronous phase profiling for multi-bearing industrial equipment.\u003c\/li\u003e\n\u003cli\u003eMulti-rack plant asset management deployments linked directly to centralized System 1 diagnostic infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 Watts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard OK Relay Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5A @ 24 Vdc \/ 120 Vac (120 Watts \/ 600 VA Switched maximum) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGold OK Relay Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 Vdc minimum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signals Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Keyphasor signals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyphasor Frequency Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20 kHz with multiple events per revolution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArc Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated arc suppressors included \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCommunication\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProtocol Supported\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Type \/ Limits\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront USB-B Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBN Host Protocol \u003c\/td\u003e\n\u003ctd\u003eUSB-B connector, 115.2 kbaud max, 5 meters max cable length \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCopper Ethernet I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBN Host Protocol \u0026amp; BN TDI Protocol via TCP\/IP \u003c\/td\u003e\n\u003ctd\u003eRJ-45 connector, 10Base-T\/100Base-TX autosensing, 100 meters max \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Optic Ethernet I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBN Host Protocol \u0026amp; BN TDI Protocol via TCP\/IP \u003c\/td\u003e\n\u003ctd\u003eMT-RJ Male connector, 100Base-FX full duplex multimode, 2000 meters max \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDynamic Channels Enabled\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMinimum Speed\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMaximum Speed\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 to 16 Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 rpm \u003c\/td\u003e\n\u003ctd\u003e100,000 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e17 to 24 Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 rpm \u003c\/td\u003e\n\u003ctd\u003e60,000 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e25 to 48 Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 rpm \u003c\/td\u003e\n\u003ctd\u003e30,000 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22°F to +149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40°F to +185°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePowered Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 years @ 50 degC (122°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnpowered Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 years @ 50 degC (122°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions (Height x Width x Depth)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRack Space Requirements\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDI Main Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) \u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lbs) \u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) \u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs) \u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Attributes\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ch4\u003eI\/O Module System Contacts \u0026amp; Terminal Block Assignments\u003c\/h4\u003e\n\u003cp\u003eThe interface layout utilizes terminal headers positioned on the rear-facing I\/O assembly to manage global systemic command interfaces.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eElectrical \/ Logic Properties\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Multiply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput control to engage Trip Multiply scaling logic \u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 mAdc, Dry Contact to Common \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Inhibit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal control to suppress all active monitor alarms \u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 mAdc, Dry Contact to Common \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Reset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal command to clear latched alarms and channel defeats \u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 mAdc, Dry Contact to Common \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Common\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pin connector grounding block to isolated instrument ground \u003c\/td\u003e\n\u003ctd\u003eMust match side switch configuration on PIM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrade Sequence Advisory:\u003c\/strong\u003e When executing a hardware modernization from an older 3500\/20 RIM assembly to the newer TDI layout, never leave old RIM I\/O boards inside the chassis. Retaining legacy components during power initialization will inflict immediate physical damage onto the new TDI hardware. The conversion sequence must follow these precise steps:\n\u003col\u003e\n\u003cli\u003eFully remove the legacy RIM main processor from the front slot.\u003c\/li\u003e\n\u003cli\u003eExtract the older RIM I\/O interface from the rear backplane slot.\u003c\/li\u003e\n\u003cli\u003eMount the new matching TDI Ethernet I\/O module into the vacant rear slot.\u003c\/li\u003e\n\u003cli\u003eSlide the main TDI processing unit into the front slot location.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Restrictions:\u003c\/strong\u003e The main interface component must occupy Slot 1 exclusively, situated directly adjacent to the primary system power supplies. It requires one full-height front allocation paired with one matching full-height rear allocation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstrument Common Isolation:\u003c\/strong\u003e When bridging the 2-pin Signal Common connector directly to an isolated single-point instrument grounding terminal, ensure the selector switch on the side of the primary Power Input Module (PIM) is slid fully toward the arrow path marked \"HP\". This isolation ensures Signal Common is safely separate from the primary chassis safety ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Panel Isolation \u0026amp; Ground Loops:\u003c\/strong\u003e When using the localized front-panel USB-B configuration channel, you must utilize the isolated factory cable (PN 123M4610) to secure decoupling between chassis elements and signal ground. Additionally, the configuration laptop must operate purely via internal battery storage, completely disconnected from mains power networks to eliminate ground loop interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Termination Matching:\u003c\/strong\u003e Installations running the fiber optic option require an explicit connector pairing. Because the physical 100Base-FX module contains a built-in MT-RJ Male terminal assembly, field engineers must terminate the incoming network fiber line with an MT-RJ Female connector block to assure optical continuity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules regarding managed signal interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU via standards EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU via product safety standard EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU hazardous materials compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e Certified under DNV GL classification rules for ships, offshore installations, high-speed craft, and ABS Steel Vessels Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (North America):\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D with operating temperature classification T4 @ Ta = -20 degC to +65 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (ATEX\/IECEx):\u003c\/strong\u003e Ex II 3G Ex nA nc ic IIC T4 Gc and Ex ec nc ic IIC T4 Gc with temperature validation T4 @ Ta = -20 degC to +65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318253419,"sku":"138607-01-2","price":5000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/138607-01_492c177e-6ee2-48cf-b587-1d665588b527.jpg?v=1783670119","url":"https:\/\/www.plcprotech.com\/pl\/products\/138607-01-bently-nevada-3500-22m-standard-transient-data-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}