{"product_id":"siemens-6av7873-0ab40-0bc0-simatic-panel-pc-677b","title":"Siemens 6AV7873-0AB40-0BC0 SIMATIC Panel PC 677B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6AV7873-0AB40-0BC0\u003c\/strong\u003e is a \u003cstrong\u003eSIMATIC Panel PC 677B\u003c\/strong\u003e designed for industrial human-machine interface (HMI) and control applications. This panel PC integrates a 15-inch key-operated display with a resolution of 1024x768, providing a robust platform for visualization and operation. It is equipped with a Celeron M440 processor running at 1.86 GHz, 3 GB of DDR2 RAM, and a 160 GB SATA hard disk drive. Connectivity options include two 10\/100\/1000 Mbit\/s Ethernet ports, four USB V2.0 ports (including one front-side interface), and one serial (COM1) port. For industrial communication, the unit features PROFINET (CP1616 compatible with 3 ports and ERTEC400 technology) and 2 MB of buffered SRAM. The system operates on a 24 V DC power supply and comes pre-installed with Windows XP Professional Multi-User Interface (MUI) supporting multiple languages.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated 15-inch key-operated display with 1024x768 resolution\u003c\/li\u003e\n\u003cli\u003eCeleron M440 processor at 1.86 GHz with 1 MB SLC\u003c\/li\u003e\n\u003cli\u003e3 GB DDR2 RAM and 160 GB SATA 3.5\" HDD\u003c\/li\u003e\n\u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet interfaces\u003c\/li\u003e\n\u003cli\u003eFour USB V2.0 ports (including one front-side) and one serial (COM1) port\u003c\/li\u003e\n\u003cli\u003ePROFINET support (CP1616 compatible, 3 ports, ERTEC400)\u003c\/li\u003e\n\u003cli\u003e2 MB buffered SRAM for data retention\u003c\/li\u003e\n\u003cli\u003ePre-installed Windows XP Professional MUI (Multi-User Interface)\u003c\/li\u003e\n\u003cli\u003e24 V DC power supply\u003c\/li\u003e\n\u003cli\u003eExpansion slots: 1x PCIe x4, 1x PCI\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens SIMATIC Panel PC 677B is suitable for a wide range of industrial automation applications, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMachine control and visualization\u003c\/li\u003e\n\u003cli\u003eProcess monitoring and data acquisition\u003c\/li\u003e\n\u003cli\u003eOperator interface for complex systems\u003c\/li\u003e\n\u003cli\u003eIndustrial data processing and communication gateways\u003c\/li\u003e\n\u003cli\u003eDistributed control system (DCS) and supervisory control and data acquisition (SCADA) environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Panel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC677B\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x USB V2.0 (1x front-side)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSerial Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x (COM1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eDisplay Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024x768\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCPU\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCeleron M440\/1.86 GHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSLC Cache\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x PCIe x4, 1x PCI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3 GB DDR2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eHard Disk Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e160 GB SATA 3.5\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePROFINET\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCP1616 compatible, 3 ports, ERTEC400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eBuffered SRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Prof. MUI (DE,EN,FR,ES,IT,JA,ZH,KO)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e60.00 x 56.50 x 30.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371098\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized and locked out before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the Panel PC securely into a panel cutout or enclosure, ensuring adequate clearance for ventilation and cable routing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated terminals, observing correct polarity. Verify the power source meets the specified voltage and current requirements.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInterface Connections:\u003c\/strong\u003e Connect Ethernet, USB, and serial cables to their respective ports. Ensure industrial-grade shielded cables are used for critical communication lines to maintain signal integrity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFINET Integration:\u003c\/strong\u003e If utilizing PROFINET, connect the appropriate cables to the PROFINET ports. Configure the network settings according to the system architecture.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure that the Panel PC's ventilation openings are not obstructed to prevent overheating, especially in enclosed environments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Install the device within its specified operating temperature and humidity ranges to ensure reliable long-term operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower On:\u003c\/strong\u003e After all connections are secure and verified, restore power to the system and observe for proper startup.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715882348907,"sku":"6AV7873-0AB40-0BC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7873-0ab40-0bc0-nwsxec3uvyh_fb6d4c71-5451-425b-b174-02418d3f6dbd.jpg?v=1767073704","url":"https:\/\/www.plcprotech.com\/pl\/products\/siemens-6av7873-0ab40-0bc0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}