{"product_id":"042h2021-danfoss-akv-20-1-electric-expansion-valve-042h2021","title":"042H2021 | Danfoss | AKV 20-1 Electric Expansion Valve (042H2021)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e042H2021 (042H2021)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAKV 20-1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries electric expansion valve designed for precise liquid injection in industrial and commercial refrigeration systems. Unlike traditional thermal expansion valves, this pulse-width modulated (PWM) valve provides superior superheat control, significantly enhancing the energy efficiency of evaporators and chillers. By reacting instantaneously to controller signals, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e042H2021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures optimal refrigerant flow even under fluctuating load conditions, which is essential for protecting compressors from liquid slugging and reducing overall energy consumption in cold storage and food processing facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAKV 20-1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a robust 13.5 mm actuator system that operates on a pulse-width modulation principle, typically driven by a Danfoss ADAP-KOOL controller. This configuration allows for a highly dynamic range of capacity, as the valve can adjust the opening time within a defined cycle. Built to withstand demanding mechanical room conditions, it supports a maximum working pressure of 28 bar (400 psig). The valve's internal geometry is optimized for clean refrigerant flow, minimizing turbulence and noise during operation. Its wide ambient temperature tolerance, ranging from -40 to 50 deg C, ensures reliable performance in both sub-zero freezing environments and high-heat equipment rooms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e042H2021 (AKV 20-1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark \/ EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eActuator System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Working Pressure (MWP)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 bar (400 psig)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Ambient Temp (Fahrenheit)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 deg F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectric Expansion Valve (PWM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eServiceability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReplaceable orifice and filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRequires compatible Danfoss coil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 4.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the PWM (Pulse Width Modulation) operation benefit the refrigeration cycle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PWM operation of the 042H2021 allows for infinitely variable capacity control. By rapidly opening and closing the valve for specific intervals, the system achieves much tighter superheat control compared to mechanical valves, leading to more stable evaporator pressures and increased COP (Coefficient of Performance).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 13.5 mm actuator system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 13.5 mm measurement refers to the armature diameter that fits the electromagnetic coil. This is a critical compatibility dimension; when selecting a replacement coil, it must match this 13.5 mm system to ensure the magnetic force is sufficient to actuate the valve against high internal pressures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this valve suitable for CO2 (R744) applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith a maximum working pressure of 28 bar, the 042H2021 is typically used for HFCs, HCFCs, and some natural refrigerants in subcritical stages. For high-pressure transcritical CO2 applications, a valve with a higher pressure rating (such as the AKVH series) would be required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Orientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure reliable operation and prevent oil or debris buildup in the actuator housing, the valve should be installed with the coil oriented upwards. Mounting with the coil hanging downwards is strongly discouraged as it may trap contaminants that cause the armature to stick.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoldering \u0026amp; Heat Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation into the copper line, the internal valve parts and gaskets must be protected from excessive heat. It is a best practice to remove the internal orifice assembly or wrap the valve body in a wet cloth during the brazing process to prevent thermal damage to the seals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AKV 20-1 series is highly sensitive to system debris. Always install a high-quality filter drier upstream of the valve. If the valve fails to close completely (leakage during the \"off\" cycle), inspect the internal orifice for particulates or wax buildup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102306099563,"sku":"042H2021","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/042h2021-mgd0wnliluh.png?v=1776136894","url":"https:\/\/www.plcprotech.com\/products\/042h2021-danfoss-akv-20-1-electric-expansion-valve-042h2021","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}