{"product_id":"134f3000-danfoss-vlt-automationdrive-fc-360-15-kw","title":"134F3000 Danfoss VLT AutomationDrive FC 360 15 KW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e134F3000 (134F3000)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance VLT AutomationDrive FC 360, engineered to provide robust and cost-effective motor control for a wide spectrum of industrial applications. Rated at 15 KW (20 HP), this frequency converter is specifically designed for \"High Overload\" scenarios, making it an ideal choice for heavy-duty machinery such as cranes, mixers, and industrial extruders where high startup torque is essential. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e134F3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a ruggedized design with coated PCBs to ensure operational continuity in harsh environments containing moisture or dust. By integrating advanced motor control algorithms and a built-in brake chopper, this drive minimizes system complexity while maximizing energy efficiency and process precision in demanding B2B manufacturing sectors.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe technical identifier\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-360H15KT4E20H2BXCDXXSXXXXA0BX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines a highly specific hardware configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFC-360\u003c\/strong\u003e: VLT AutomationDrive series optimized for general-purpose industrial automation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH\u003c\/strong\u003e: Rated for High Overload (150% torque for 60 seconds).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e15K\u003c\/strong\u003e: Power capacity of 15 KW \/ 20 HP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT4\u003c\/strong\u003e: Three-phase mains voltage range of 380-480 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20\u003c\/strong\u003e: IP20 \/ Chassis enclosure designed for cabinet installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH2\u003c\/strong\u003e: Integrated RFI Class A2 filter for electromagnetic compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB\u003c\/strong\u003e: Includes an integrated Brake Chopper for dynamic braking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX (Display)\u003c\/strong\u003e: Supplied without a display (No blind cover).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eC\u003c\/strong\u003e: Coated PCBs for enhanced environmental protection against corrosives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eD\u003c\/strong\u003e: Loadsharing capability via DC bus connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAX\u003c\/strong\u003e: Standard Control Card interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e134F3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 KW \/ 20 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Overload (160% for 1 min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 to 480 VAC (3-Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRFI Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass A2 (Industrial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrake Chopper\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCB Coating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coated (Class 3C3)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C (with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.05 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I program the 134F3000 since it is supplied without a display?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince this unit features the \"X\" display option, you must use an external LCP (Local Control Panel) for manual commissioning, or connect via the built-in RS485 port to a PC using Danfoss MCT 10 software for configuration and diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"D\" Loadsharing option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Loadsharing option allows the DC buses of multiple drives to be connected. This enables energy produced by a motor in generator mode (during braking) to be used by other drives on the same bus, significantly reducing energy waste and thermal load on braking resistors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 134F3000 suitable for corrosive environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"C\" suffix indicates that the internal circuit boards are conformal coated. This provides superior protection against salt, moisture, and chemical pollutants compared to non-coated variants, extending the drive's service life in industrial zones.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBrake Resistor Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e134F3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes an integrated brake chopper, an external brake resistor is required to dissipate energy during rapid deceleration of high-inertia loads. Ensure the resistor value (Ohms) and wattage match the drive's technical manual specifications to prevent over-voltage trips or chopper damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAt 15 KW, the drive generates significant heat during full-load operation. Ensure the cabinet has forced ventilation capable of maintaining an ambient temperature below 40 deg C for optimal performance. Allow for a minimum of 100 mm vertical clearance above and below the chassis for unimpeded airflow through the heat sink.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDC Bus Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the Loadsharing (D option) feature, ensure that all drives are connected to the same AC mains source to prevent circulating currents. Always wait at least 15 minutes after power-down before servicing the DC terminals, as the capacitors remain energized at lethal voltage levels.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102413807979,"sku":"134F3000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/134f3000-15tgxcpdtid.png?v=1776137066","url":"https:\/\/www.plcprotech.com\/products\/134f3000-danfoss-vlt-automationdrive-fc-360-15-kw","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}