{"product_id":"138607-01-bently-nevada-3500-22m-standard-transient-data-interface-module","title":"138607-01 | Bently Nevada | 3500\/22M Standard Transient Data Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e138607-01 (138607-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the core\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStandard Transient Data Interface (TDI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule for the Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. As the primary communication gateway for the 3500 Machinery Protection System, this module is responsible for bridging the gap between hardware monitors and diagnostic software. Unlike standard interface modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to handle \"transient\" data—capturing high-resolution waveforms during machine start-up, coast-down, and steady-state operation. This capability is critical for vibration specialists to perform orbit, spectrum, and time-base analysis, ensuring the long-term reliability of high-speed rotating assets.\u003c\/p\u003e\n\u003ch3\u003eFunctional Engineering \u0026amp; Diagnostic Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M 138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the processing intelligence required to manage all monitor modules within a 3500 rack. It performs continuous self-diagnostics and manages the communication flow to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. By collecting dynamic data from the backplane, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for a \"Black Box\" forensic approach to machinery protection; it can trigger high-speed data captures based on alarm events, providing engineers with the exact vibration profiles leading up to a machine trip. This module is the \"Standard\" version, optimized for typical industrial monitoring applications where intrinsic safety barriers are handled externally.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e138607-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Collection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatic, Dynamic (Waveforms), and Transient Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet (via I\/O module) \u0026amp; USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-volatile flash for configuration and event logs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFront Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB port for local rack configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus LEDs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOK, TX\/RX, TM (Test Mode), and CONFIG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 138607-01 differ from the 3500\/20 RIM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe legacy 3500\/20 Rack Interface Module (RIM) only supports static data (overall vibration values). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M TDI (138607-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-bandwidth upgrade that enables the capture of raw waveforms, which is the only way to perform detailed diagnostics in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 138607-01 be installed in any slot of the 3500 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The TDI must always be installed in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efirst slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(leftmost side, Slot 1) of the 3500 rack, immediately next to the Power Supply modules. This position is required to manage the rack-wide communication bus effectively.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the front-panel USB port?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe USB port on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLocal Configuration\u003c\/strong\u003e. It allows a field engineer to connect a laptop directly to the rack to set up sensor types, alarm setpoints, and network parameters using the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen replacing a 138607-01, ensure the firmware version matches the rest of the rack modules and your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion. Discrepancies can lead to communication errors or the inability to capture transient events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Upload:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore commissioning, the module must be \"configured.\" Connect via USB, set the specific rack address and IP settings, and then upload the configuration. The module will retain this information in its non-volatile memory even after a power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Procedure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports replacement while the rack is powered. However, when the TDI is removed, all communication to the diagnostic software will stop. The individual monitor modules will still provide hardware-level machinery protection (trips), but remote visibility will be lost until the new module is synchronized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M 138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an essential investment for any plant operating turbines, compressors, or large pumps. Its ability to provide deep-dive forensic data makes it the gold standard for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRoot Cause Analysis (RCA)\u003c\/strong\u003e. Built for extreme industrial durability, this module ensures that your machinery protection system is not just a \"trip box\" but a powerful diagnostic tool that reduces unplanned downtime and extends the life of critical equipment.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318253419,"sku":"138607-01-2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/138607-01_bently_nevada-jovg24rn2bi_73c2f3d1-1189-4536-b724-735a9c7ce710.jpg?v=1765521098","url":"https:\/\/www.plcprotech.com\/products\/138607-01-bently-nevada-3500-22m-standard-transient-data-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}