{"product_id":"200-psmg-abb-series-200-master-dc-dc-power-supply-unit","title":"200-PSMG ABB Series 200 Master DC\/DC Power Supply Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-PSMG (492898801R)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Master DC\/DC Power Supply Unit specifically engineered for the ABB Series 200 I\/O and controller system. As the primary power backbone for automation clusters, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-PSMG (492898801R)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts raw DC input into stable, regulated voltage required for the logic circuits of connected controllers and functional modules.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-31 citation-end-31\"\u003eDesigned for the rigors of industrial environments, it features robust load regulation and transient protection, ensuring that fluctuating factory power does not compromise the integrity of process control data.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-30 citation-end-30\"\u003eIts compact, modular design allows for seamless integration into DIN-rail or panel-mounted Series 200 assemblies, making it a critical component for maintaining system uptime in manufacturing and process industries.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200-PSMG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e492898801R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaster DC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem-compatible DC Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegulated DC (Logic Level)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail \/ Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Series 200 footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85044090\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirective 2011\/65\/EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C (Standard Industrial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the role of a \"Master\" power supply in a Series 200 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"Master\" unit like the 200-PSMG is responsible for providing the internal logic power to the backplane. Unlike auxiliary supplies that power field-side devices (sensors\/actuators), the Master unit ensures the processor and communication bus remain active and stable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 200-PSMG compatible with third-party DC sources?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, as long as the DC source meets the input voltage requirements and ripple specifications defined for the Series 200 system. However, for maximum EMI\/RFI protection, using ABB-certified power sources is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 200-PSMG is a single master unit. For high-availability applications requiring redundancy, engineers typically implement dual-feed DC architectures or utilize specific redundant power modules if the controller rack configuration supports them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the output is overloaded?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features electronic short-circuit and overload protection. In the event of a fault, the unit will typically limit current or shut down to protect the sensitive logic modules on the Series 200 bus.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure long-term capacitor health, maintain a minimum of 20 mm clearance above and below the unit for natural convection. In high-density cabinets where the internal temperature exceeds 45 deg C, active cooling or additional spacing is required to prevent derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the DIN rail is properly bonded to the functional earth (FE) of the cabinet. The 200-PSMG relies on a low-impedance ground path to effectively shunt high-frequency noise and protect the Master controller's logic circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor the DC input for voltage drops during heavy inductive load switching (e.g., large motors or solenoids). If significant sagging occurs, install a decoupling capacitor or a dedicated buffer module upstream of the 200-PSMG to prevent \"brown-out\" resets of the Master controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958504811,"sku":"200-PSMG","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/200-psmg-hpaa4qgtwjh_56c81d84-9106-4063-91cb-033548e7b927.jpg?v=1766478155","url":"https:\/\/www.plcprotech.com\/products\/200-psmg-abb-series-200-master-dc-dc-power-supply-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}