{"product_id":"330102-00-40-10-11-cn-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330102-00-40-10-11-CN Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330102-00-40-10-11-CN (330102-00-40-10-11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a cornerstone component of the Bently Nevada 3300 XL 8 mm Proximity Transducer System. This eddy-current probe is specifically engineered for non-contact measurement of static and dynamic shaft displacement, including radial vibration, axial thrust position, and speed\/keyphasor applications. Featuring a 3\/8-24 UNF threaded body and integrated stainless steel armor, this probe is designed to withstand the turbulent conditions inside industrial machinery housings. By delivering high-linearity signals to a 3300 XL Proximitor Sensor, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330102-00-40-10-11-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables precise condition monitoring for critical rotating assets such as steam turbines, centrifugal compressors, and cooling tower fans, effectively preventing catastrophic failures through early mechanical fault detection.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330102-00-40-10-11-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by the following technical configurations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330102\u003c\/strong\u003e: 3300 XL 8 mm Probe with 3\/8-24 UNF threads and factory-installed stainless steel armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Unthreaded Length)\u003c\/strong\u003e: 0.0 inches; the probe case is fully threaded for maximum mounting flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e40 (Overall Case Length)\u003c\/strong\u003e: 4.0 inches total housing length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10 (Total Length)\u003c\/strong\u003e: 1.0 meter (3.3 feet) integrated cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e11 (Connector\/Cable Type)\u003c\/strong\u003e: Equipped with the miniature coaxial ClickLoc connector and includes connector protectors for enhanced interface durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN (Agency Approval)\u003c\/strong\u003e: Certified for hazardous areas under Chinese NEPSI standards and international compliance protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330102-00-40-10-11-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 mm (0.31 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.8 bar (70 psi) tip to case\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e302\/304 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this probe require a specific extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330102-00-40-10-11-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be used with a 3300 XL extension cable. For a 1.0-meter probe, a 4.0-meter or 8.0-meter extension cable is typically used to reach a total system length of 5.0 or 9.0 meters, matching the Proximitor Sensor's calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the ClickLoc connector (Option 11)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector features a robust, moisture-resistant design that \"clicks\" when fully seated, preventing accidental disconnection due to vibration and ensuring a low-impedance electrical path for the RF signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe compatible with older 3300 series Proximitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 3300 XL 8 mm probe is physically compatible with non-XL 3300 systems, it is highly recommended to use the complete 3300 XL system to achieve the advertised 7.87 V\/mm (200 mV\/mil) linearity and improved thermal stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Gapping and Linearity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring installation, the probe must be positioned within its linear range. Connect a digital multimeter to the Proximitor output and adjust the probe position until the \"Gap Voltage\" reads approximately -10 VDC (the midpoint of the -2 to -18 VDC linear range). Ensure the locknut is torqued correctly to prevent the probe from \"backing out\" during machine operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMagnetic Side-Loading and Clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent \"side-loading\" or interference with the measurement signal, maintain a minimum clearance of two tip diameters (16 mm) between the probe tip and any surrounding conductive material other than the target shaft. Failure to provide adequate clearance will result in an incorrect scale factor and non-linear vibration readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection and Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated stainless steel armor protects the coaxial cable from mechanical abrasion and light crushing. However, avoid routing the cable near high-voltage AC lines. Use the provided connector protectors to prevent oil and moisture ingress at the probe-to-extension cable junction, as contamination is the leading cause of signal \"noise\" or false alarms.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323987819,"sku":"330102-00-40-10-11-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330102-00-40-10-11-cn-5zkset0tht3_87cec66c-add1-4aee-9d26-7ff46fee7e11.jpg?v=1765521254","url":"https:\/\/www.plcprotech.com\/products\/330102-00-40-10-11-cn-bently-nevada-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}