{"product_id":"330877-080-36-cn-bently-nevada-3300-xl-50-mm-extension-cable","title":"330877-080-36-CN Bently Nevada 3300 XL 50 mm Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN (330877-080-36-CN)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 3300 XL 50 mm extension cable manufactured by Bently Nevada, specifically engineered for critical machinery protection and proximity sensor systems. As a vital component of the 3300 XL 50 mm Proximitor sensor system, this cable maintains signal integrity between the probe and the Proximitor sensor in large-scale rotating equipment. Featuring the specialized FluidLoc technology and PFA insulation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to prevent hazardous fluids from wicking through the cable, making it an essential solution for oil-filled environments such as turbines, compressors, and large industrial pumps in the oil and gas or power generation sectors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a 75 ohm triaxial architecture, insulated with perfluoroalkoxyethylene (PFA) to ensure extreme temperature resilience and chemical resistance. This specific configuration features a cable length of 8.0 meters (26.2 feet) and utilizes the \"36\" FluidLoc option, which provides an additional layer of protection against fluid migration—a common cause of sensor failure in pressurized machinery. The \"CN\" agency approval indicates country-specific compliance, ensuring the hardware meets rigorous safety and technical standards for localized industrial deployments. With a typical capacitance of 69.9 pF\/m, the cable is tuned to maintain the precise electrical characteristics required for accurate vibration and position measurements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330877-080-36-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 50 mm Extension Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 meters (26.2 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm triaxial, PFA insulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor\/Cable Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc technology (Option 36)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +200 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +200 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (Country Specific)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the FluidLoc (Option 36) cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc extension cable is specifically designed with a proprietary internal seal that prevents oil, moisture, or other process fluids from leaking through the inside of the cable. This protects the Proximitor sensor electronics from contamination if a probe seal fails in an oil-filled machine housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 330877-080-36-CN compatible with standard 3300 XL 8 mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This extension cable is specifically designed for the 3300 XL 50 mm system. The electrical characteristics (capacitance and impedance) of 50 mm cables differ from 8 mm or 11 mm systems. Using mismatched cables will result in significant calibration errors and inaccurate machinery vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable withstand extreme high-temperature environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Thanks to the PFA (perfluoroalkoxyethylene) insulation, the cable is rated for continuous operation in temperatures ranging from -51 Celsius to +200 Celsius, making it suitable for mounting inside hot turbine enclosures or near steam lines.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation, ensure the miniature coaxial connectors remain clean and dry. Use a silicone lubricant only on the connector threads if required by the manual, but never on the signal-carrying pins. It is highly recommended to use connector protectors or heat-shrink tubing to seal the connection point between the probe and the extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo avoid damaging the triaxial shielding and the FluidLoc seal, observe the minimum bend radius during routing. Avoid sharp 90-degree bends; instead, use sweeping curves to maintain the 75 ohm impedance and prevent signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRouting and Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough grounded metal conduit wherever possible. Avoid running the extension cable parallel to high-voltage AC motor leads or VFD cables, as electromagnetic interference (EMI) can introduce noise into the low-voltage proximity signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318679403,"sku":"330877-080-36-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330877-080-36-cn-aqxqi3pbqbs_b6b0a565-3d1e-4920-94a6-c1ddfde9ed58.jpg?v=1765521112","url":"https:\/\/www.plcprotech.com\/products\/330877-080-36-cn-bently-nevada-3300-xl-50-mm-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}