{"product_id":"8v1016-00-2-b-r-acopos-multi-axis-servo-drive","title":"8V1016.00-2 B\u0026R ACOPOS Multi-Axis Servo Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8V1016.00-2 (8V1016.00-2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact and highly efficient servo drive from the B\u0026amp;R ACOPOS series, designed to provide high-precision motion control for small-scale industrial applications. Engineered for flexibility, this drive supports a wide mains input voltage range from 230 VAC to 480 VAC, making it a versatile choice for global power standards. In sectors such as pick-and-place robotics, labeling machinery, and precise pharmaceutical packaging, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8V1016.00-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers exceptional dynamic performance with an installed load of 2.1 kVA. By integrating 3 slots for plug-in modules, it allows for easy expansion of communication interfaces and encoder systems, ensuring that the drive can adapt to evolving automation requirements while maintaining a small footprint and reducing overall system complexity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 8V1016.00-2 is built on a high-performance power stage capable of switching frequencies up to 20 kHz. It features an integrated line filter compliant with EN 61800-3 Category C3, which effectively suppresses electromagnetic interference and ensures stable operation within industrial environments. The drive manages power efficiently, with a maximum inrush current of only 2 A and a power dissipation of 110 W at nominal load. For logic and control, the unit requires a 24 VDC input, consuming a maximum of 1.47 A plus the current required for a motor holding brake. The hardware supports a maximum motor line length of 15 meters and can output frequencies up to 598 Hz, providing the necessary bandwidth for high-speed brushless DC and synchronous AC motors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8V1016.00-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACOPOS Servo Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMains Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3x 230 VAC to 480 VAC (plus\/minus 10 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstalled Load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 2.1 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Switching Freq\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kHz (Configurable 5\/10\/20 kHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.3 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePeak Power Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (plus 25 percent \/ minus 20 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExpansion Slots\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 (for plug-in modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Line Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (Category C3)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Dissipation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the configurable switching frequency affect drive performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8V1016.00-2 allows for 5, 10, or 20 kHz switching. Higher frequencies (20 kHz) provide smoother motor motion and quieter operation but increase thermal dissipation. Lower frequencies (5 kHz) reduce heat loss in the drive but may increase audible noise and current ripple in the motor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"Switch-on interval\" for this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe switch-on interval must be greater than 10 seconds. This duration allows the internal inrush current limiting circuit to cool down and reset. Repeatedly cycling the mains power faster than every 10 seconds can lead to premature failure of the charging resistors or the internal relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre external filters required for CE compliance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 8V1016.00-2 includes an integrated line filter according to EN 61800-3 Category C3, additional external filters are typically not required for standard industrial installations (Second Environment). However, for applications in residential areas (First Environment), additional filtering may be necessary.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the drive is mounted vertically in the control cabinet. With a power dissipation of 110 W, adequate airflow is mandatory. If multiple drives are mounted in a row, maintain the minimum specified side-to-side clearance to prevent thermal cascading, which can trigger the \"overtemperature\" fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Cable Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain EMI compliance and prevent signal interference, use only shielded motor cables with a maximum length of 15 meters. The shield must be connected to the drive’s ground plate using a 360-degree contact clamp. Avoid \"pigtail\" grounding, as it is ineffective at the high switching frequencies (10-20 kHz) used by the ACOPOS system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBraking Resistor Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 110 W dissipation rating is calculated without an external braking resistor. For applications involving high-inertia loads or frequent deceleration, an external braking resistor must be connected to manage regenerative energy and prevent \"DC Bus Overvoltage\" errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086376788331,"sku":"8V1016.00-2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8v1016.00-2-jyzvu1zx3rz.png?v=1776137185","url":"https:\/\/www.plcprotech.com\/products\/8v1016-00-2-b-r-acopos-multi-axis-servo-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}