{"product_id":"990-05-xx-01-cn-mod-165335-10-bently-nevada-990-vibration-transmitter","title":"990-05-XX-01-CN MOD: 165335-10 | Bently Nevada | 990 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-XX-01-CN MOD: 165335-10\u003c\/strong\u003e is a loop-powered, two-wire \u003cstrong\u003e990 Vibration Transmitter\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (a Baker Hughes business) to provide continuous machinery protection by interfacing directly with industrial control networks. This field-mountable device combines the signal conditioning electronics of a proximity sensor and a transmitter into a single, compact housing. It accepts input signals from a non-contacting 3300 XL 8mm eddy-current proximity probe and extension cable, processing raw high-frequency micro-gap changes into a linear 4 to 20 mA analog current loop. This continuous current loop can be routed straight to standard Distributed Control Systems (DCS), Programmable Logic Controllers (PLC), or process data recorders without the added complexity of a separate, rack-based machinery protection monitor.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features a factory-calibrated \u003cstrong\u003efull-scale measurement scale of 0-5 mils pp (0-125 um pp)\u003c\/strong\u003e, optimized for tracking radial shaft vibration amplitudes on rotating machinery. The transmitter body is equipped with standard \u003cstrong\u003e35 mm DIN rail clips\u003c\/strong\u003e for rapid, secure snap-on mounting into field marshalling enclosures or local junction boxes. Certified with the \u003cstrong\u003eCN agency approval option\u003c\/strong\u003e, this hardware meets stringent international and regional safety frameworks, including ATEX\/IECEx and Chinese NEPSI hazardous area standards for classified zones. The specialized suffix \u003cstrong\u003eMOD: 165335-10\u003c\/strong\u003e designates a factory-controlled engineering modification that provides precise hardware component matching or specific internal filter tuning tailored to optimized machinery metrics while maintaining identical physical dimensions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire, loop-powered design that routes a proportional 4 to 20 mA analog signal directly to host DCS or PLC automation cards.\u003c\/li\u003e\n\u003cli\u003eStandardized 0-5 mils peak-to-peak (0-125 um peak-to-peak) linear scale calibration for high-accuracy shaft displacement metrics.\u003c\/li\u003e\n\u003cli\u003eIntegrated heavy-duty 35 mm DIN rail mounting clips for toolless, secure installation on standard terminal enclosure tracks.\u003c\/li\u003e\n\u003cli\u003eDual hazardous zone certifications combining global ATEX\/IECEx standards with local Chinese NEPSI industrial safety markings.\u003c\/li\u003e\n\u003cli\u003eFactory modification code MOD: 165335-10 for specialized circuit optimization and application-specific operational stability.\u003c\/li\u003e\n\u003cli\u003eFront-mounted, isolated BNC dynamic terminal providing raw, unconditioned voltage waveforms for local diagnostic data collectors.\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span adjustment pots allowing seamless, independent calibration verification under field conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandalone radial shaft vibration monitoring on fluid-filmed bearings of industrial centrifugal air compressors and turbo-fans.\u003c\/li\u003e\n\u003cli\u003eDirect asset protection loop integration for medium-sized balance-of-plant electric motors and high-speed centrifugal pumps.\u003c\/li\u003e\n\u003cli\u003eDistributed machinery condition monitoring inside remote oil and gas transport pipeline stations or utility water pumps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOption String Breakdown\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter Product Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Full-scale Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003e0-5 mils peak-to-peak (0-125 um peak-to-peak) measurement scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: System Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-XX\u003c\/td\u003e\n\u003ctd\u003eConfigurable system loop length (Matches probe\/cable design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips factory-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-CN\u003c\/td\u003e\n\u003ctd\u003eCombined ATEX\/IECEx and Chinese NEPSI hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModification Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOD: 165335-10\u003c\/td\u003e\n\u003ctd\u003eSpecialized factory hardware configuration modification code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-01-CN MOD: 165335-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Proximity Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Scale Linear Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mils pp (0 to 125 um pp) peak-to-peak displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Loop Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProportional 4 to 20 mAdc current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 7.87 V\/mm (200 mV\/mil) corresponding to raw probe gap voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm nominal (Protected against continuous short circuit faults)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 Vdc to +35 Vdc loop power required at the terminal links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Core Matching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibrated for standard 3300 XL 8mm proximity probe and extension cable loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Block Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal strip accepting wire cross-sections up to 1.5 mm squares (16 to 24 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Construction Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate body structure integrated with an aluminum base plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.50 kg (3.3 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% maximum, non-condensing atmosphere constraints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROBE Coaxial Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial connection point receiving the incoming transducer extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+ (SIG) Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive current loop connection receiving incoming +12 to +35 Vdc loop power inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e- (COM) Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative current loop connection returning the regulated 4 to 20 mA measurement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF BNC Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel isolated BNC socket providing unconditioned sensor voltage waves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment:\u003c\/strong\u003e Position the transmitter housing directly over standard 35 mm DIN rail tracking. Apply firm downward pressure until the integrated plastic clips snap tightly over the rail flanges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Frame Isolation:\u003c\/strong\u003e Ensure the internal ground planes remain isolated from bare electrical conduit paths. The transmitter backplate must remain isolated from structural rack frames to eliminate low-voltage ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Verification:\u003c\/strong\u003e Verify that the system length option (Option -XX) perfectly matches the combined physical length of the connected 3300 XL 8mm probe and extension cable to maintain proper scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Signal Diagnostic Check:\u003c\/strong\u003e Use the front-facing coaxial BNC connector to patch into local signal analyzers. This buffered port provides a raw voltage wave (200 mV\/mil) without altering the primary 4-20 mA control loop tracking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668313796971,"sku":"990-05-XX-01-CN 165335-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/990-05-xx-01-cnmod165335-10-xi10dyajhlr_659df02a-7992-49d4-83f6-9ad9bf34fead.jpg?v=1765520943","url":"https:\/\/www.plcprotech.com\/products\/990-05-xx-01-cn-mod-165335-10-bently-nevada-990-vibration-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}