{"product_id":"abb-1khw001432r0001-p3lg-bay-control-system-human-machine-interface","title":"ABB 1KHW001432R0001 P3LG Bay Control System Human Machine Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 1KHW001432R0001 P3LG\u003c\/strong\u003e is a specialized \u003cstrong\u003eHuman Machine Interface (HMI)\u003c\/strong\u003e module engineered for integration within ABB Bay Control Systems and Distributed Control System (DCS) architectures. Serving as a crucial local operator interaction node, this module provides real-time visualization, control interface access, and system diagnostics for power automation and substation bay control environments.\u003c\/p\u003e\n\u003cp\u003eConstructed with a rugged aluminum alloy enclosure and finished with a corrosion-resistant coating, the \u003cstrong\u003e1KHW001432R0001 P3LG\u003c\/strong\u003e is built to maintain reliable operation under harsh industrial conditions. The unit features built-in thermal resilience, supporting operational temperature ranges from -20 degC to +60 degC and storage tolerance from -40 degC to +70 degC.\u003c\/p\u003e\n\u003cp\u003eTo support robust data exchange across automation networks, the interface is equipped with 4 RS-232 serial communications ports and 2 Ethernet connections with integrated Ethernet routing capability. This multi-interface setup enables direct, reliable linkups to host DCS units, local controllers, and networked field devices.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in Ethernet router functionality across dual Ethernet ports for flexible DCS network integration.\u003c\/li\u003e\n\u003cli\u003eFour RS-232 serial interfaces for direct legacy control unit or field device connectivity.\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade aluminum alloy housing with corrosion resistance for harsh field environments.\u003c\/li\u003e\n\u003cli\u003eExtended operating temperature range of -20 degC to +60 degC.\u003c\/li\u003e\n\u003cli\u003ePurpose-built for ABB Bay Control Systems in DCS applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLocal monitoring and control interface for substation bay control hardware.\u003c\/li\u003e\n\u003cli\u003eOperator interface node within industrial Distributed Control Systems (DCS).\u003c\/li\u003e\n\u003cli\u003eData routing and serial-to-Ethernet communication gateway in power automation panels.\u003c\/li\u003e\n\u003cli\u003eField-level diagnostic and parameter access point for utility and heavy industrial installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1KHW001432R0001 P3LG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHuman Machine Interface (HMI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem \/ Range\u003c\/td\u003e\n\u003ctd\u003eBay Control System \/ DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eAluminum alloy with corrosion-resistant finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003e4 x RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Service\u003c\/td\u003e\n\u003ctd\u003eEthernet router\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (D x W x H)\u003c\/td\u003e\n\u003ctd\u003e4.5 x 24.7 x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCompliance and Certifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Certifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, FCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports (x2)\u003c\/td\u003e\n\u003ctd\u003eNetwork communication and integrated Ethernet routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232 Ports (x4)\u003c\/td\u003e\n\u003ctd\u003eSerial communication links to local controllers\/devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Unpack the module and inspect the aluminum chassis and connector ports for physical damage before mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the HMI module into the panel cutout or rack assembly using appropriate hardware, ensuring adequate clearance around the unit for ambient heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect a low-impedance protective earth ground wire to the chassis grounding terminal to mitigate electrical noise and static discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring \u0026amp; Cabling:\u003c\/strong\u003e Connect network cables to the Ethernet interfaces and secure serial devices to the RS-232 ports using shielded cables to ensure reliable data transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Initial Verification:\u003c\/strong\u003e Verify that supply voltages match system requirements before powering up the panel. Confirm LED status indicators show normal communication initialization.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Configuration:\u003c\/strong\u003e Configure IP addresses, subnet masks, and routing parameters via the designated setup tool to integrate the HMI into the DCS Ethernet topology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port Setup:\u003c\/strong\u003e Verify baud rate, parity, data bits, and stop bits for each RS-232 interface to match connected field units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Procedure:\u003c\/strong\u003e When replacing an existing 1KHW001432R0001 P3LG unit, document all network settings and serial configurations, power down the bay segment, swap physical connections, and upload the verified configuration file to the new HMI.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668620603755,"sku":"1KHW001432R0001 P3LG","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-1khw001432r0001-p3lg-human-machine-interface-pahlge441mw_ba3c54e8-9aa3-47d5-881b-dd98246ede1e.jpg?v=1765535775","url":"https:\/\/www.plcprotech.com\/products\/abb-1khw001432r0001-p3lg-bay-control-system-human-machine-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}