{"product_id":"abb-1saj530000r0200-umc100-3-dc-universal-motor-controller","title":"ABB 1SAJ530000R0200 UMC100.3 DC Universal Motor Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 1SAJ530000R0200\u003c\/strong\u003e (type designation \u003cstrong\u003eUMC100.3 DC\u003c\/strong\u003e) is an intelligent motor management device designed for comprehensive motor protection, control, and fault monitoring. Powered by a 24 V DC control supply voltage, this compact controller provides advanced motor protection against overload and phase failure across an operational current setting range of 0.24 A to 63 A directly.\u003c\/p\u003e\n\u003cp\u003eEquipped with 6 digital inputs, 4 digital outputs, and a dedicated PTC thermistor input, the \u003cstrong\u003eUMC100.3 DC\u003c\/strong\u003e integrates control logic with physical process signals. It supports flexible industrial network integration and can connect to fieldbus and Ethernet communication networks via optional communication adapters. Additionally, this model holds ATEX approval for motor protection in hazardous environment applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePowered by a 24 V DC auxiliary control supply\u003c\/li\u003e\n\u003cli\u003eDirect current setting range from 0.24 A to 63 A\u003c\/li\u003e\n\u003cli\u003eConfigurable overload trip protection supporting classes 5E, 10E, 20E, 30E, and 40E\u003c\/li\u003e\n\u003cli\u003eIntegrated I\/O layout featuring 6 digital inputs, 4 digital outputs, and 1 PTC thermistor input\u003c\/li\u003e\n\u003cli\u003eATEX certified for protected motor operation in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003eModular communication design supporting PROFIBUS DP, Modbus RTU, Modbus TCP, PROFINET, and EtherNet\/IP via optional interface modules\u003c\/li\u003e\n\u003cli\u003eDesigned for main circuit operational voltages up to 690 V AC and 1000 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntelligent Motor Control Center (MCC) panels and low-voltage switchgear installations\u003c\/li\u003e\n\u003cli\u003eOverload and thermal protection for three-phase AC induction motors in process automation\u003c\/li\u003e\n\u003cli\u003eHazardous area motor management requiring ATEX certified protective devices\u003c\/li\u003e\n\u003cli\u003eHeavy industrial drives and grinding system control blocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e1SAJ530000R0200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Main Type\u003c\/td\u003e\n\u003ctd\u003eUMC100.3 DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMotor management device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e275 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Dimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e70 mm x 106 mm x 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Operating Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Control Supply Voltage ($U_s$)\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003eMain Circuit: 690 V AC \/ 1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Voltage (UL\/CSA)\u003c\/td\u003e\n\u003ctd\u003eMain Circuit: 600 V AC; Auxiliary Circuit: 230 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current ($I_e$)\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Setting Range\u003c\/td\u003e\n\u003ctd\u003e0.24 ... 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Main Frequency ($f$)\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Class\u003c\/td\u003e\n\u003ctd\u003eClass 5E, 10E, 20E, 30E, 40E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage ($U_{imp}$)\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Circuit: 4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInput \/ Output\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Inputs\u003c\/td\u003e\n\u003ctd\u003e1 PTC Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eWiring \u0026amp; Mechanical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnecting Capacity\u003c\/td\u003e\n\u003ctd\u003e1x 0.2-2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnecting Capacity (UL\/CSA)\u003c\/td\u003e\n\u003ctd\u003e1x 28-12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003eControl \/ Auxiliary Circuit: 0.5 N·m (8 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Stripping Length\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Screwdriver\u003c\/td\u003e\n\u003ctd\u003ePozidriv 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Mounting Distance\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Position\u003c\/td\u003e\n\u003ctd\u003ePosition 1 ... 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature\u003c\/td\u003e\n\u003ctd\u003eOperation: 0 ... +60 Celsius; Storage: -25 ... +70 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance to Shock\u003c\/td\u003e\n\u003ctd\u003e15g, 1 shock, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance to Vibrations\u003c\/td\u003e\n\u003ctd\u003e4g, 2 ... 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the auxiliary control supply is a clean 24 V DC power source before energizing the module.\u003c\/li\u003e\n\u003cli\u003eMount the UMC100.3 DC onto a standard DIN rail or panel surface in any permissible mounting position (1 to 6). Zero minimum mounting distance is required between adjacent devices.\u003c\/li\u003e\n\u003cli\u003eStrip control and auxiliary wiring to 7 mm and secure into the screw terminals using a Pozidriv 1 screwdriver tightened to 0.5 N·m (8 in-lb).\u003c\/li\u003e\n\u003cli\u003eRoute the primary motor phase conductors through the integrated internal current transformers according to standard three-phase sequencing.\u003c\/li\u003e\n\u003cli\u003eConnect external PTC temperature sensors to the dedicated PTC input terminals if motor winding temperature monitoring is required.\u003c\/li\u003e\n\u003cli\u003eSnap on the required communication interface module (e.g., PROFINET, PROFIBUS, or Modbus) or control panel cable onto the front expansion port.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect and lock out all main three-phase power lines and the 24 V DC auxiliary control power supply before performing servicing.\u003c\/li\u003e\n\u003cli\u003eRecord or back up the current parameter profile using the UMC100-PAN control panel or FDT\/DTM software prior to removing the faulty device.\u003c\/li\u003e\n\u003cli\u003eLabel all control and digital I\/O wiring harnesses connected to the terminal blocks before removal.\u003c\/li\u003e\n\u003cli\u003eUnclip the existing unit from the DIN rail and mount the replacement 1SAJ530000R0200 module.\u003c\/li\u003e\n\u003cli\u003eReconnect screw terminals to specified torque limits and download the original configuration parameters into the new UMC100.3 DC unit.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion Protection:\u003c\/strong\u003e ATEX certified (IEC\/EN 60079-7)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety \u0026amp; Standards:\u003c\/strong\u003e IEC\/EN 60947-1, IEC\/EN 60947-4-1, IEC\/EN 60947-5-1, IEC\/EN 60947-8, UL 508, CAN\/CSA C22.2 No.60947-1, CAN\/CSA C22.2 No.60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Declarations:\u003c\/strong\u003e CE, CCC, cULus, ABS, DNV, CB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Directives:\u003c\/strong\u003e RoHS (Directive 2011\/65\/EU), REACH\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53764790223211,"sku":"1SAJ530000R0200","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1SAJ530000R0200_001_1200x1200_9cc5b2e0-a4e3-412b-80f6-2e74f24aa25b.jpg?v=1787666869","url":"https:\/\/www.plcprotech.com\/products\/abb-1saj530000r0200-umc100-3-dc-universal-motor-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}